2
![Page 3: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/3.jpg)
Upon completion of this course, student should be able to :
Identify air pollution control for particle pollutant Choose air pollution control device for particle pollutant Understand air pollution control method for gas
pollutant Describe adsorption method for control gas pollutant Describe absorption method for control gas pollutant Describe condensation method for control gas pollutant
![Page 4: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/4.jpg)
Technology for Air Pollution Control
![Page 5: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/5.jpg)
Techniques Without Using Emissions Control Devices Process Change
Wind, Geothermal, Hydroelectric, or Solar Unit instead of Fossil fired Unit.
Change in Fuel e.g. Use of Low Sulfur Fuel, instead of High Sulfur fuel.
Good Operating Practices Good Housekeeping Maintenance
Plant Shutdown
![Page 6: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/6.jpg)
Commonly Used Methods For Air Pollution ControlPARTICULATE
Cyclones Electrostatic Precipitators Fabric Filter Wet Scrubbers
GASES Adsorption Towers Thermal Incernation Catalytic Combustion
![Page 7: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/7.jpg)
SOx CONTROL
![Page 8: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/8.jpg)
GENERAL METHODS FOR CONTROL OF SO2 EMISSIONS Change to Low Sulfur Fuel
Natural Gas Liquefied Natural Gas Low Sulfur Oil
Low Sulfur Coal
Use Desulfurized Coal and Oil Increase Effective Stack Height Build Tall Stacks Redistribution of Stack Gas Velocity Profile Modification of Plume Buoyancy
![Page 9: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/9.jpg)
General Methods for Control of SO2 Emissions (contd.) Use Flue Gas Desulfurization Systems
Use Alternative Energy Sources, such as Hydro-Power or Nuclear-Power
![Page 10: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/10.jpg)
Flue Gas Desulfurization SO2 scrubbing, or Flue Gas Desulfurization processes
can be classified as: Throw away or Regenerative, depending upon whether the recovered
sulfur is discarded or recycled. Wet or Dry, depending upon whether the scrubber is a liquid or a solid.
Flue Gas Desulfurization Processes The major flue gas desulfurization ( FGD ), processes are : Limestone Scrubbing Lime Scrubbing Dual Alkali Processes Lime Spray Drying Wellman-Lord Process
![Page 11: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/11.jpg)
Limestone Scrubbing Limestone slurry is sprayed on the incoming flue
gas. The sulfur dioxide gets absorbed The
limestone and the sulfur dioxide react as
follows :
CaCO3 + H2O + 2SO2 ----> Ca+2 + 2HSO3-+ CO2
CaCO3 + 2HSO3-+ Ca+2 ----> 2CaSO3 + CO2 +
H2O
![Page 12: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/12.jpg)
Limestone Scrubbing
![Page 13: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/13.jpg)
Lime Scrubbing
![Page 14: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/14.jpg)
Lime Scrubbing The equipment and the processes are similar to those
in limestone scrubbing Lime Scrubbing offers better utilization of the reagent. The operation is more flexible. The major disadvantage is the high cost of lime compared to limestone.
The reactions occurring during lime scrubbing are :
CaO + H2O -----> Ca(OH)2
SO2 + H2O <----> H2SO3
H2SO3 + Ca(OH)2 -----> CaSO3.2 H2OCaSO3.2 H2O + (1/2)O2 -----> CaSO4.2 H2O
![Page 15: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/15.jpg)
Dual Alkali System Lime and Limestone scrubbing lead to deposits inside spray tower. The deposits can lead to plugging of the nozzles through which the
scrubbing slurry is sprayed. The Dual Alkali system uses two regents to remove the sulfur
dioxide. Sodium sulfite / Sodium hydroxide are used for the absorption of
sulfur dioxide inside the spray chamber. The resulting sodium salts are soluble in water,so no deposits are
formed. The spray water is treated with lime or limestone, along with make-
up sodium hydroxide or sodium carbonate. The sulfite / sulfate ions are precipitated, and the sodium
hydroxide is regenerated.
![Page 16: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/16.jpg)
Lime – Spray DryingLime Slurry is sprayed into the chamber
The sulfur dioxide is absorbed by the slurry
The liquid-to-gas ratio is maintained such that the spray dries before it reaches the bottom of the chamber
The dry solids are carried out with the gas, and are collected in fabric filtration unit
This system needs lower maintenance, lower capital costs, and lower energy usage
![Page 17: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/17.jpg)
Wellman – Lord Process This process consists of the following
subprocesses: Flue gas pre-treatment. Sulfur dioxide absorption by sodium sulfite Purge treatment Sodium sulfite regeneration. The concentrated sulfur dioxide stream is processed to a
marketable product.
The flue gas is pre - treated to remove the particulate. The sodium
sulfite neutralizes the sulfur dioxide : Na2SO3 + SO2 + H2O -----> 2NaHSO3
![Page 18: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/18.jpg)
Wellman – Lord Process (contd.) Some of the Na2SO3 reacts with O2 and the SO3 present in the flue
gas to form Na2SO4 and NaHSO3.
Sodium sulfate does not help in the removal of sulfur dioxide, and
is removed. Part of the bisulfate stream is chilled to precipitate the
remaining bisulfate. The remaining bisulfate stream is evaporated
to release the sulfur dioxide, and regenerate the bisulfite.
![Page 19: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/19.jpg)
Wellman – Lord ProcessSchematic process flow diagram – SO2 scrubbing and recovery system
![Page 20: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/20.jpg)
NOX CONTROL
![Page 21: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/21.jpg)
Background on Nitrogen Oxides
There are seven known oxides of nitrogen : NO
NO2
NO3
N2O
N2O3
N2O4
N2O5
NO and NO2 are the most common of the seven oxides listed
above. NOx released from stationary sources is of two types
![Page 22: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/22.jpg)
General Methods For Control Of NOx Emissions
NOx control can be achieved by: Fuel Denitrogenation
Combustion Modification
Modification of operating conditions
Tail-end control equipment Selective Catalytic Reduction
Selective Non - Catalytic Reduction
Electron Beam Radiation
Staged Combustion
![Page 23: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/23.jpg)
Fuel Denitrogenation
o One approach of fuel denitrogenation is to remove a large part of the
nitrogen contained in the fuels. Nitrogen is removed from liquid fuels
by mixing the fuels with hydrogen gas, heating the mixture and using a
catalyst to cause nitrogen in the fuel and gaseous hydrogen to unite.
This produces ammonia and cleaner fuel.
This technology can reduce the nitrogen contained in both naturally
occurring and synthetic fuels.
![Page 24: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/24.jpg)
Combustion Modification Combustion control uses one of the following
strategies: Reduce peak temperatures of the flame zone. The methods are :
increase the rate of flame cooling decrease the adiabatic flame temperature by dilution
Reduce residence time in the flame zone. For this we, change the shape of the flame zone
Reduce Oxygen concentration in the flame one. This can be accomplished by:
decreasing the excess air controlled mixing of fuel and air using a fuel rich primary flame zone
![Page 25: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/25.jpg)
Modification Of Operating Conditions
The operating conditions can be modified to achieve significant reductions in the rate of thermal NOx production. the various methods are: (reduce NOx) Low-excess firing Off-stoichiometric combustion ( staged combustion ) Flue gas recirculation Reduced air preheat Reduced firing rates
Water Injection
![Page 26: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/26.jpg)
Tail-end Control Processes o Combustion modification and modification of
operating conditions provide significant reductions in NOx, but not enough to meet regulations.
For further reduction in emissions, tail-end control equipment is required.
Some of the control processes are:
Selective Catalytic Reduction Selective Non-catalytic Reduction Electron Beam Radiation Staged Combustion
![Page 27: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/27.jpg)
Selective Catalytic Reduction (SCR)
Schematic process flow diagram – NOX control
![Page 28: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/28.jpg)
Selective Catalytic Reduction (SCR)
In this process, the nitrogen oxides in the flue gases are reduced to
nitrogen
During this process, only the NOx species are reduced
NH3 is used as a reducing gas
The catalyst is a combination of titanium and vanadium oxides. The
reactions are given below :
4 NO + 4 NH3 + O2 -----> 4N2 + 6H2O
2NO2 + 4 NH3+ O2 -----> 3N2 + 6H2O
Selective catalytic reduction catalyst is best at around 300 too 400 oC.
Typical efficiencies are around 80 %
![Page 29: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/29.jpg)
Catalytic Combustion
![Page 30: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/30.jpg)
Catalytic Emission Control
![Page 31: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/31.jpg)
Electron Beam Radiation This treatment process is under development,
and is not widely used. Work is underway to determine the feasibility of electron beam radiation for neutralizing hazardous wastes and air toxics.
Irradiation of flue gases containing NOx or SOx produce nitrate and sulfate ions.
The addition of water and ammonia produces NH4NO3, and (NH4)2SO4
The solids are removed from the gas, and are sold as fertilizers.
![Page 32: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/32.jpg)
Staged Combustion PRINCIPLE
Initially, less air is supplied to bring about incomplete combustion
Nitrogen is not oxidized. Carbon particles and CO are released.
In the second stage, more air is supplied to complete the combustion of carbon and carbon monoxide.
30% to 50% reductions in NOx emissions are achieved.
![Page 33: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/33.jpg)
Staged Combustion
![Page 34: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/34.jpg)
CARBON MONOXIDE CONTROL
![Page 35: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/35.jpg)
Formation Of Carbon Monoxide
Due to insufficient oxygen
Factors affecting Carbon monoxide formation: Fuel-air ratio
Degree of mixing
Temperature
![Page 36: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/36.jpg)
General Methods For Control of CO Emissions
Control carbon monoxide formation. Note : CO & NOx control strategies are in conflict.
Stationary Sources Proper Design Installation Operation Maintenance
Process Industries Burn in furnaces or waste heat boilers.
![Page 37: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/37.jpg)
CARBON DIOXIDE CONTROL
![Page 38: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/38.jpg)
Sources of Carbon DioxideHuman-Related Sources Combustion of fossil fuels: Coal, Oil, and Natural
Gas in power plants, automobiles, and industrial facilities
Use of petroleum-based products Industrial processes: Iron and steel production,
cement, lime, and aluminum manufactures
Natural Sources Volcanic eruptions Ocean-atmosphere exchange Plant photosynthesis
![Page 39: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/39.jpg)
Sources of CO2 Emissions in the U.S.
Source: USEPA
(x-axis units are teragrams of CO2 equivalent)
![Page 40: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/40.jpg)
CO2 Emissions from Fossil Fuel Combustion by Sector and Fuel Type
Source: USEPA
(y-axis units are teragrams of CO2 equivalent)
![Page 41: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/41.jpg)
General Methods For Control of CO2 Emissions
Reducing energy consumption, increasing the efficiency of energy conversion
Switching to less carbon intensive fuels
Increasing the use of renewable sources
Sequestering CO2 through biological, chemical, or physical processes
![Page 42: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/42.jpg)
CONTROL OF MERCURY EMISSIONS
![Page 43: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/43.jpg)
Mercury Emissions Mercury exists in trace amounts in
Fossil fuels such as Coal, Oil, and Natural GasVegetationWaste products
Mercury is released to the atmosphere through combustion or natural processes
It creates both human and environmental risks Fish consumption is the primary pathway for human
and wildlife exposure United states is the first country in the world to
regulate mercury emissions from coal-fired power plants (March 15, 2005).
![Page 44: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/44.jpg)
Source: Seingeur, 2004 and Mason and Sheu, 2002.
Source: Presentation by J. Pacyna and J. Munthe at mercury workshop in Brussels, March 29-30, 2004
Types of Sources
Worldwide Distribution of Emissions
![Page 45: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/45.jpg)
Control Technologies for Mercury Emissions
Currently installed control devices for SO2, NOX, and particulates, in a power plant, remove some of the mercury before releasing from the stack
Activated Carbon Injection: Particles of activated carbon are injected into the exit gas flow, downstream
of the boiler. The mercury attaches to the carbon particles and is removed in a particle control device
Thief process for the removal of mercury from flue gas:It is a process which extracts partially burned coal from a pulverized coal-
fired combustor using a suction pipe, or "thief," and injects the resulting sorbent into the flue gas to capture the mercury.
![Page 46: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/46.jpg)
PARTICULATE MATTER CONTROL
![Page 47: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/47.jpg)
General Methods For Control Of Particulate Emissions
Five Basic Types of Dust Collectors :
Gravity and Momentum collectors Settling chambers, louvers, baffle chambers
Centrifugal Collectors Cyclones Mechanical centrifugal collectors
Fabric Filters Baghouses Fabric collectors
![Page 48: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/48.jpg)
General Methods For Control Of Particulate Emissions (Contd.)
Electrostatic Precipitators Tubular Plate Wet Dry
Wet Collectors Spray towers Impingement scrubbers Wet cyclones Peaked towers Mobile bed scrubbers
![Page 49: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/49.jpg)
General Methods For Control Of Particulate Emissions
Five Basic Types of Dust Collectors :
Gravity and Momentum collectors Settling chambers, louvers, baffle chambers
Centrifugal Collectors Cyclones Mechanical centrifugal collectors
Fabric Filters Baghouses Fabric collectors
![Page 50: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/50.jpg)
Particulate Collection Mechanism
Gravity Settling
Centrifugal Impaction
Inertial Impaction
Direct Interception
Diffusion
Electrostatic Effects
![Page 51: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/51.jpg)
![Page 52: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/52.jpg)
Industrial Sources of Particulate Emissions Iron & Steel Mills, the blast furnaces, steel making furnaces. Petroleum Refineries, the catalyst regenerators, air-blown asphalt
stills, and sludge burners. Portland cement industry Asphalt batching plants Production of sulfuric acid Production of phosphoric acid Soap and Synthetic detergent manufacturing Glass & glass fiber industry Instant coffee plants
![Page 53: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/53.jpg)
Effects of Particulate Emissions Primary Effects • Reduction of visibility
• size distribution and refractive index of the particles • direct absorption of light by particles • direct light scattering by particles • 150 micro g / m3 concentration ~ average visibility of 5 miles
( satisfactory for air and ground transportation )
• Soiling of nuisance• increase cost of building maintenance, cleaning of furnishings,
and households • threshold limit is 200 - 250 micro g / m3 ( dust ) • levels of 400 - 500 micro g / m3 considered as nuisance
![Page 54: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/54.jpg)
Cyclones
Principle • The particles are removed by the application of a centrifugal
force. The polluted gas stream is forced into a vortex. the motion of the gas exerts a centrifugal force on the particles, and they get deposited on the inner surface of the cyclones
• centrifugal force to capture, recover or remove large and high-volume dust from industrial applications.
Overall collection ηCi inlet concentration
Co outlet concentration
![Page 55: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/55.jpg)
![Page 56: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/56.jpg)
Cyclones (contd.)Construction and Operation
The gas enters through the inlet, and is forced into a spiral. • At the bottom, the gas reverses direction and flows upwards.
• To prevent particles in the incoming stream from contaminating the clean gas, a vortex finder is provided to separate them. the cleaned gas flows out through the vortex finder.
![Page 57: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/57.jpg)
Cyclones (contd.) Advantages of Cyclones
• Cyclones have a lost capital cost • Reasonable high efficiency for specially designed cyclones. • They can be used under almost any operating condition. • Cyclones can be constructed of a wide variety of materials. • There are no moving parts, so there are no maintenance
requirements.
Disadvantages of Cyclones • They can be used for small particles • High pressure drops contribute to increased costs of operation.
![Page 58: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/58.jpg)
Fabric Filters Principle
The filters retain particles larger than the mesh size
Air and most of the smaller particles flow through. Some of the smaller particles are retained due to interception and diffusion.
The retained particles cause a reduction in the mesh size.
The primary collection is on the layer of previously deposited particles.
![Page 59: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/59.jpg)
Design of Fabric Filters The equation for fabric filters is based on
Darcy’s law for flow through porous media. Fabric filtration can be represented by the
following equation:S = Ke + KswWhere,S = filter drag, N-min/m3
Ke = extrapolated clean filter drag, N-min/m3
Ks = slope constant. Varies with the dust, gas and fabric, N-min/kg-mW= Areal dust density = LVt, where L = dust loading (g/m3), V = velocity (m/s)
Both Ke and Ks are determined empirically from pilot tests.
![Page 60: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/60.jpg)
Fabric Filters
Δ P Total pressure drop
Δ Pf Pressure drop due to the fabric
Δ Pp Pressure drop due to the particulate layer
Δ Ps Pressure drop due to the bag house structure
![Page 61: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/61.jpg)
Advantages of Fabric Filters Very high collection efficiency
They can operate over a wide range of volumetric flow rates
The pressure drops are reasonably low.
Fabric Filter houses are modular in design, and can be pre-assembled at the factory
![Page 62: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/62.jpg)
Fabric Filters (contd.) Disadvantages of Fabric Filters
Fabric Filters require a large floor area.
The fabric is damaged at high temperature.
Ordinary fabrics cannot handle corrosive gases.
Fabric Filters cannot handle moist gas streams
A fabric filtration unit is a potential fire hazard
![Page 63: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/63.jpg)
ΔPfPressure drop N/m2
ΔPp Pressure drop N/m2
Df Depth of filter in the direction of flow (m)
Dp Depth of particulate layer in the direction of flow (m)
μ Gas viscosity kg/m-sV superficial filtering velocity m/minKf, Kp Permeability (filter & particulate layer m2)
60 Conversion factor δ/minV = Q/A
Q volumetric gas flow rate m3/minA cloth area m2
Darcy’s equation
![Page 64: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/64.jpg)
L Dust loading kg/m3
t time of operation minρL Bulk density of the particulate layer kg/m3
ΔP = ΔPf + ΔPp
Filter Drag S = ΔP/VAreal dust density W = LVtS= k1+k2W
Dust Layer
![Page 65: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/65.jpg)
Electrostatic Precipitator Principle
The particles in a polluted gas stream are charged by passing them through an electric field.
The charged particles are led through collector plates The collector plates carry charges opposite to that on the particles The particles are attracted to these collector plates and are thus removed from
the gas steam
Construction and Operation of Electrostatic Precipitator Charging Electrodes in the form of thin wires are placed in the path of the
influent gas. The charging electrodes generate a strong electric field, which charges the
particles as they flow through it. The collector plates get deposited with the particles. the particles are
occasionally removed either by rapping or by washing the collector plates.
![Page 66: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/66.jpg)
Design of Electrostatic Precipitators The efficiency of removal of particles by an
Electrostatic Precipitator is given by
η = fractional collection efficiency
w = drift velocity, m/min.A = available collection area, m2
Q = volumetric flow rate m3/min
![Page 67: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/67.jpg)
Migration velocity
Where, q = charge (columbos)
Ep = collection field intensity (volts/m)r = particle radius (m)μ = dynamic viscosity of gas (Pa-S)c = cunningham correction factor
![Page 68: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/68.jpg)
Cunningham correction factor
where,T = absolute temperature (°k)dp = diameter of particle (μm)
![Page 69: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/69.jpg)
ELECTROSTATIC PRECIPITATOR (contd.) Advantages of Electrostatic Precipitators
Electrostatic precipitators are capable very high efficiency, generally of the order of 99.5-99.9%.
Since the electrostatic precipitators act on the particles and not on the air, they can handle higher loads with lower pressure drops.
They can operate at higher temperatures. The operating costs are generally low.
Disadvantages of Electrostatic Precipitators The initial capital costs are high. Although they can be designed for a variety of operating
conditions, they are not very flexible to changes in the operating conditions, once installed.
Particulate with high resistivity may go uncollected.
![Page 70: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/70.jpg)
Wet Scrubbers Principle
Wet scrubbers are used for removal of particles which have a diameter of the order of 0.2 mm or higher.
Wet scrubbers work by spraying a stream of fine liquid droplets on the incoming stream.
The droplets capture the particles The liquid is subsequently removed for treatment.
Construction and Operation A wet scrubber consists of a rectangular or circular chamber in
which nozzles are mounted. The nozzles spray a stream of droplets on the incoming gas stream The droplets contact the particulate matter, and the particles get
sorbed. The droplet size has to be optimized.
![Page 71: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/71.jpg)
![Page 72: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/72.jpg)
Wet Scrubbers (contd.)o Construction and Operation (contd.)
Smaller droplets provide better cleaning, but are more difficult to remove from the cleaned stream.
The polluted spray is collected. Particles are settled out or otherwise removed from the liquid. The liquid is recycled. Wet scrubbers are also used for the removal of gases from the air
streams.
![Page 73: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/73.jpg)
Scrubber Efficiency
where,k = Scrubber coefficient (m3 of gas/ m3 of liquid)R = Liquid-to-gas flow rate (QL/QG)ψ = internal impaction parameter
Internal impaction parameter
where,c = cunningham correction factorρp = particle density (kg/m3)Vg = speed of gas at throat (m/sec)dp = diameter of particle (m)
dd = diameter of droplet (m)μ = dynamic viscosity of gas, (Pa-S)
![Page 74: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/74.jpg)
Wet Scrubbers (contd.) Advantages of Wet Scrubbers
Wet Scrubbers can handle incoming streams at high temperature, thus
removing the need for temperature control equipment. Wet scrubbers can handle high particle loading. Loading fluctuations do not affect the removal efficiency. They can handle explosive gases with little risk. Gas adsorption and dust collection are handled in one unit. Corrosive gases and dusts are neutralized.
Disadvantages of Wet Scrubbers High potential for corrosive problems Effluent scrubbing liquid poses a water pollution problem.
![Page 75: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/75.jpg)
Cyclone Spray Chambers These scrubbers combine a cyclone with a spray
nozzle.
The added centrifugal force permits good
separation of the droplets, hence a smaller droplet
size can be used.
Cyclone spray chambers provide up to 95% removal
of particles > 5 micron.
![Page 76: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/76.jpg)
Orifice Scrubbers The gas is impacted onto a layer of the scrubbing
liquid.
The gas passes through the liquid, thus removing
almost all the particulate matter, and a large
portion of the probable gases. After coming out of the liquid, the gas is passed
through baffles to remove the liquid droplets.
![Page 77: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/77.jpg)
Impingement Scrubbers In Impingement scrubbers, the gas impacts a layer
of liquid/froth through a perforated tray.
Passing through this layer removes the particulate
matter.
The wet gas stream is then passed through a mist
collector.
![Page 78: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/78.jpg)
Venturi Scrubbers The dirty gas is led in to the chamber at high inlet
velocities. At the inlet throat, liquid at low pressure is added
to the gas stream This increases the relative velocity between the gas
and the droplets, thus increasing the efficiency of removal.
Efficiencies of the range of 95% for particles larger than 0.2 mm have been obtained.
![Page 79: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/79.jpg)
Venturi ScrubberAbsolute Pressure Drop
Δp = pressure drop ( cm of water)ug = gas velocity (cm/s)
Qt = liquid volume flow rate
Qg = gas volume flow rate
![Page 80: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/80.jpg)
HYDROCARBON CONTROL
![Page 81: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/81.jpg)
General Methods For Control Of Hydrocarbon Emissions
Incineration or after burning
Direct flame incineration
Thermal incineration
Catalytic incineration
![Page 82: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/82.jpg)
VOC Incinerators Principle
VOC incinerators thermally oxidize the effluent stream, in the presence of excess air.
The complete oxidation of the VOC results in the formation of carbon monoxide and water. The reaction proceeds as follows:
CxHy + ( x + y/4 ) O2 x CO2 + (y/2) H2O Operation
The most important parameters in the design and operation of an incineration system are what are called the ' three T's ' Temperature, Turbulence, and residence Time.
![Page 83: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/83.jpg)
VOC Incinerators (contd.) Temperature
The reaction kinetics are very sensitive to temperature The higher the temperature, the faster the reaction
o Timing A certain time has to be provided for the reaction to proceed
o Turbulence
Turbulence promotes mixing between the VOC's and oxygen Proper mixing helps the reaction to proceed to completion in the
given time.
![Page 84: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/84.jpg)
VOC Incinerators (contd.) The various methods for incineration are:
Elevated fires, for concentrated streams
Direct thermal oxidation, for dilute streams
Catalytic oxidation, for dilute streams.
![Page 85: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/85.jpg)
Xi volume of i component in the mixture
Xm volume of mixture
LELi LEL of i component
![Page 86: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/86.jpg)
GASES
![Page 87: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/87.jpg)
Air Pollution Control For Gases
Adsorption Towers
Thermal Incernation
Catalytic Combustion
![Page 88: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/88.jpg)
Adsorption Towers Principle
Adsorption towers use adsorbents to remove the impurities
from the gas stream.
The impurities bind either physically or chemically to the
adsorbing material.
The impurities can be recovered by regenerating the adsorbent.
Adsorption towers can remove low concentrations of impurities
from the flue gas stream.
![Page 89: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/89.jpg)
Adsorption Towers (contd.) Construction and Operation
Adsorption towers consist of cylinders packed with the adsorbent. The adsorbent is supported on a heavy screen Since adsorption is temperature dependent, the flue gas is
temperature conditioned. Vapor monitors are provided to detect for large concentrations in the
effluent. Large concentrations of the pollutant in the effluent indicate that the adsorbent needs to be regenerated.
Advantages of Adsorption Towers Very low concentrations of pollutants can be removed. Energy consumption is low. Do not need much maintenance. Economically valuable material can be recovered during regeneration.
![Page 90: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/90.jpg)
Adsorption Towers (contd.) Disadvantages of adsorption Towers
Operation is not continuous.
They can only be used for specific pollutants.
Extensive temperature pre-conditioning equipment to be
installed.
Despite regeneration, the capacity of the adsorbent decreases
with use.
![Page 91: Chapter 4 air pollution control and tecnologies](https://reader035.vdocuments.us/reader035/viewer/2022062408/58f0e4961a28abf56f8b459f/html5/thumbnails/91.jpg)
The End!!!