Chapter 15 – Pinch TechnologyHeat Exchange Networks
Chemical Process Design
West Virginia University
Copyright - R. Turton and J. Shaeiwitz, 2012
1
![Page 2: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/2.jpg)
The Need to Heat and Cool Process Streams
• Feed usually enters a process from a storage vessel that is maintained at ambient temperature. If it is to be reacted at an elevated temperature, it must be heated.
• After the reaction has taken place, the reactor effluent stream must be purified, which usually requires cooling the stream, and possibly condensing it, prior to separating it.
• Thus energy must first be added, then removed.
![Page 3: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/3.jpg)
Heat IntegrationHeat exchange networksIt saves money to match streams rather than pay to heat one and pay to cool another
••
• You have already done thisbasis in design projects
on ad hoc
Copyright - R. Turton and J. Shaeiwitz, 2012
3
![Page 4: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/4.jpg)
The Concept of Heat Integration
• The concept of Heat Integration, in its simplest form, is to find matches between heat additions and heat removals within the process.
• In this way, the total utilities that are used to perform these energy transfers can be minimized, or rather optimized.
• The number of heat exchangers needed to perform these energy transfers can also be minimised.
![Page 5: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/5.jpg)
Outline•Heat Integration•Design Procedure for MUMNE (Minimum Utility, Minimum Number of Exchangers)- Temperature interval diagram- Cascade diagram- Temperature – Enthalphy diagram- Minimum number of heat exchangers- Design above and below pinch
![Page 6: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/6.jpg)
Heat IntegrationThere is a rigorous methodology We will learn MUMNE (Minimum Utility, Minimum Number ofExchangers) method
••
• Not necessarily (andeconomic optimum
unlikely to be)
Copyright - R. Turton and J. Shaeiwitz, 2012
4
![Page 7: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/7.jpg)
Design ProcedureComplete energy balance on all streams to
1.determine allflows.
temperatures, m C p values, and heat
2. Choose minimum approach temperature. Typically,this is between 5°C and 20°C, but any positivenumber is valid.
3. Complete temperature interval diagram, Eachstream is drawn and labeled.interval is calculated.
The heat flow in each
Copyright - R. Turton and J. Shaeiwitz, 2012
5
![Page 8: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/8.jpg)
Design Procedure (continued 1)4. Complete the cascade diagram. The energy excess
or deficit is calculated for each interval on thetemperature interval diagram.
Find the minimum hot and cold utility requirements and identify the pinch temperature. Complete the composite temperature enthalpy
5.
6.diagram.process.
This is a T-Q diagram for the entire
Copyright - R. Turton and J. Shaeiwitz,
2012
6
![Page 9: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/9.jpg)
Design Procedure (continued 2) Determine the minimum number of heat7.exchangers required above and below the pinch.
8. Design the heat exchanger network.
Copyright - R. Turton and J. Shaeiwitz,
2012
7
![Page 10: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/10.jpg)
Example Problem Stream Properties for Example Problems
Copyright - R. Turton and J. Shaeiwitz, 2012
8
Stream Tin Tout
m Cp
kW/°CQ
kW1 200 120 3 240
2 140 100 5 200
3 100 170 3 -210
4 110 190 2 -160
Net heat flow
70
![Page 11: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/11.jpg)
Example Problem (continued 1)The value of Q might not be given in above table,1.or Q is given and mC p is missing. These arecalculated from the energy balance. The signconvention is positive for heat available from astream and negative for heat needed by a stream.
2. Choose the minimum approachthis problem, it is 10°C.
temperature. For
Copyright - R. Turton and J. Shaeiwitz, 2012
9
![Page 12: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/12.jpg)
Example Problem (continued 2) Draw and label the temperature interval diagram.Label the intervals beginning with “A” for the
3.
highest temperature interval. The heat flow for m C p Teach interval is calculated from, Q , where
interval.the sum is over all streams existing in that
Copyright - R. Turton and J. Shaeiwitz, 2012
10
![Page 13: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/13.jpg)
Example Problem (continued 3)4. In this temperature interval diagram, each process
stream is represented by a vertical line with an arrow at the end indicating the direction of temperature change.
5. Horizontal lines are then drawn through the ends of the vertical lines to divide the diagram into temperature intervals.
![Page 14: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/14.jpg)
Copyright - R. Turton and J. Shaeiwitz, 2012
11
![Page 15: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/15.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
12
![Page 16: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/16.jpg)
Example Problem (continued 4)6. Draw the cascade diagram. This represents the
cascade of heat flowing down from high to lowtemperatures. Add utilities where needed. Labelthe heat flows. The net utility flow should agreewith the net heat flow on the earlier table.
Copyright - R. Turton and J. Shaeiwitz, 2012
13
![Page 17: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/17.jpg)
Cascade
Diagram
2060Hot
Utility
Pinch Temp130-140C
60
80130
ColdUtility
Copyright - R. Turton and J. Shaeiwitz, 2012
14
E50
D20
C60
B-80
A20
![Page 18: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/18.jpg)
Example Problem (continued 5)
7. On the cascade diagram, there will be a location where the heat-flow cascade is not continuous. This represents the pinch temperature
![Page 19: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/19.jpg)
Example Problem (continued 6)Construct the composite temperature enthalpy8.diagram. This provides useful information, but it isnot required to solve the problem.
Copyright - R. Turton and J. Shaeiwitz, 2012
15
![Page 20: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/20.jpg)
Example Problem
Hot
(continued 7) Cold
Copyright - R. Turton and J. Shaeiwitz, 2012
16
interval T(°C)
Q(kW)
T(°C)
Q(kW)
E 100 90
D 110 50 100
C 120 100 110 30
B 140 260 130 130
A 180 380 170 330
200 440 190 370
![Page 21: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/21.jpg)
Example Problem (continued 8)In the table, the temperature shown is from the lower end
summingto the
of the interval. The Q values are obtained byall m C p T existing on the interval and adding itprevious interval. The temperature difference is forthat interval. The m C p value is the sum
of all existing
streams on that interval.
Copyright - R. Turton and J. Shaeiwitz,
2012
17
![Page 22: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/22.jpg)
Example Problem (continued 8)
The hot and cold stream lines are plotted, as shown on the following figure. Clearly, there is a temperature cross, so the cold stream line is shifted to the right until the minimum approach temperature of 10°C exists at one point. (It could exist at more than one point by coincidence.) For this problem, all Q values for the cold stream must be increased by 130 kW, as shown in the figure. Note how the hot and cold utility requirements are apparent from the diagram.
Copyright - R. Turton and J. Shaeiwitz, 2012
18
![Page 23: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/23.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
200
T(°
C)
QH=60
180
160
140
10°C - minimum approach temp.
120
100Q
c=130
0 100 200 300 400
500 600
Q(kW)hot stream cold streamcold stream adjusted
Composite T-Q Diagram 19
![Page 24: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/24.jpg)
Example Problem (continued 9)
7. The easiest way to determine the minimum number of heat exchangers is to draw boxes to represent the heat available in each stream and from the utilities both above and below the pinch. This identifies the minimum number, but not necessarily the correct stream matches. The correct number of heat exchangers is the number of process streams + the number of utility streams – 1.
![Page 25: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/25.jpg)
above
HU60
pinch - 3 exchangers1
180
below pinch
160
- 4 exchangers
2200
60 60 120 60 30 13040
4120
3120
440
390
CU130
Each arrow identifies one heat exchanger,Total number of arrows is total number of heat exchangers,but not necessarily the correct stream matches.
Top number in a box is stream number.Bottom number in a box i s energy in the stream.Number on arrow is energy transferred in a heat exchanger.
HU : Hot Utility CU : Cold Utility
Copyright - R. Turton and J. Shaeiwitz, 2012
21
![Page 26: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/26.jpg)
Example Problem (continued 10)
Note that if a “direct match” is found, i.e., where sets of two streams match heat flows
8.
exactly, one fewer exchanger may appear tobe possible. However, be careful, theminimumviolated.
approach temperature may be
Copyright - R. Turton and J. Shaeiwitz, 2012
22
![Page 27: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/27.jpg)
Example Problem (continued 11)
Design the heat exchange network.9. Theremay not be unique streams here. Thedesign is started at the pinch and you workaway from the pinch. Above the pinch, foranycan
streams that exist at the pinch,only be matched such that
streams
m CpH m
CpC
Copyright - R. Turton and J. Shaeiwitz, 2012
23
![Page 28: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/28.jpg)
Example Problem (continued 12)
When dealing with streams away from the pinch, this criterion is no longer needed. Any streams can be matched as long as the
10.
temperatures are valid. If the criterion atthe pinch appears impossible to satisfy,streams can be split to satisfy the criterion.
Copyright - R. Turton and J. Shaeiwitz, 2012
24
![Page 29: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/29.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
25
![Page 30: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/30.jpg)
Example Problem (continued 13)11. From the previous diagram, stream 1 can
be matched with stream 3 or 4. Note that, for this step, only streams that are present at the pinch are considered.
12. The next step is to transfer heat from hot to cold stream by placing a heat exchanger (1) in the temperature diagram.
![Page 31: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/31.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
26
![Page 32: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/32.jpg)
Example Problem (continued 14)13. Heat exchanger (1) transfers Q1= 120 from
stream 1 to stream 3. This fulfils requirement of stream 3.
14. There is still remaining Q2 = 60 in stream 1 which can be transferred to stream 4 by adding another heat exchanger (2) as in the following diagram.
![Page 33: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/33.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
27
![Page 34: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/34.jpg)
Example Problem (continued 15)
15. Next, heat exchanger (3) is used to transfer Q3 = 60 from Hot Utilities to Stream 3.
![Page 35: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/35.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
28
![Page 36: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/36.jpg)
Example Problem (continued 16)
The same procedure is done below the pinch, except that the criterion is
mC p H mC pC
16.
17. Streams are matched and heat exchangers areadded until all required heat transfer isaccomplished. The entire network, both aboveand below the pinch, can then be represented onone diagram.
Copyright - R. Turton and J. Shaeiwitz, 2012
29
![Page 37: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/37.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
30
![Page 38: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/38.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
31
![Page 39: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/39.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
32
![Page 40: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/40.jpg)
In-class Example ProblemStream Properties for In-class Example Problem
Copyright - R. Turton and J. Shaeiwitz, 2012
33
Stream Tin Tout m
kg/sCp
kJ/kg°C
1 250 100 1 1
2 280 120 2 2
3 100 200 1 2
4 120 230 1 5
![Page 41: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/41.jpg)
In-class Example Problem
Determine (minimum approach T = 20°C)
a.
b.c.
minimum hot and cold utility consumption
pinch temperaturesminimum number of heat exchangersrequired above and below the pinch
d. design of heat exchange network abovebelow the pinch
and
Copyright - R. Turton and J. Shaeiwitz, 2012
34
![Page 42: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/42.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
35
![Page 43: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/43.jpg)
Cascade
Diagram
120
120
40HotUtility Pinch
Temp120-140C
6080 Cold
Utility
Copyright - R. Turton and J. Shaeiwitz, 2012
36
E20
D60
C-160
B0
A120
![Page 44: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/44.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
8040
above pinch - 4 exchangers
1 2 HU110 560 40
110 10 550 40
3 4160 550
below pinch - 2 exchangers, if possible
1 2
40 80
3 CU40 80
37
![Page 45: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/45.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
1
4
sp lit
38
![Page 46: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/46.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
39
![Page 47: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/47.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
40
![Page 48: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/48.jpg)
Copyright - R. Turton and J. Shaeiwitz,
2012
41
![Page 49: Chapter 15 - Heat Exchanger Networks - I](https://reader033.vdocuments.us/reader033/viewer/2022061612/5695d0e21a28ab9b02944596/html5/thumbnails/49.jpg)
Summary
•••
Heat Exchange Networks
Well-established procedureNot necessarily (and unlikely to be) economic optimum but a very good starting point
• Straight forward, but must be carefulmatching streams at pinch
Different correct answers possible
when
•
Copyright - R. Turton and J. Shaeiwitz, 2012
42