changzhou haida medical equipment coimgusr.tradekey.com/images/uploadedimages/brochures/3/3/... ·...
TRANSCRIPT
Changzhou Haida Medical Equipment Co., Ltd
Changzhou Haida Medical Equipment Co., Ltd is the innovative
manufacturer of disposable medical devices. With the central focus on
patients’ safety and users’ comfort we offer cost-effective quality
products.
We are proud of maintaining our certified quality management system
based on ISO 9001:2000, ISO13485:2003 that helps us to serve our
clients better. Moreover, we have also our products CE marked.
Haida Medical offers very wide range of stapling units that are widely
used in the modern surgery.
The complete line of the mechanical stapling systems includes:
- Circular staplers
- Linear staplers
- Linear cutter staplers
-Hemorrhoids staplers
-Reusable linear staplers
-Skin stapler
-Disposable curved cutter stapler
-Endo linear cutter stapler
1.Disposable linear staplers:
There are two types of the linear staplers manufactured by Haida–
semi-automatic and manually operated – so that requirements of all the users
are met.
Appropriate cartridges that can be used with linear staplers ensure
cost-effective, single patient use of the product.
Compact construction and modern design concordant with modern standards
ensure patient’s and user’s safety.
Haida Medical
2
Product
Code No. of Staples
Shape height (mm) Suture length (mm)
HS-30 11 1.0-2.5 30
HS-45 15 1.0-2.5 45
HS-60 21 1.0-2.5 60
HS-90 33 1.0-2.5 90
Features:For disposal operation, avoid the possibility of cross infection.
You can adjust the closure height of the nail room according to the thickness of
the tissue.
There are five specifications to meet the requirements of different suture
length.
Equipped with a standby nail room which can be used in the same operation
Function and Application
Linear Stapler HS can be used to conduct anastomoses through firing into the
tissues two staggered rows of titanium staples instead of manual stitching. It
can reduce operative time and bleeding and provide ease of use.
This linear stapler is suitably used for incision anastomosis in alimentary canal
surgery such as stomach and enteron.
Configuration
Linear Stapler HS mainly consists of anvil closure assembly and staples firing
assembly. Turn the adjusting knob clockwise, drive the movable module to
slide in the two cradles by lead screw, freely adjust the height of staple
formation and the gap between the anvil and the end of movable module. The
adjusting results can be seen from the firing indicator window.
In order not to influence proper formation because of the movement of the
movable module, there is a position setting pin which can ensure movable
module to move properly. Furthermore, it allows repositioning of tissue within
instrument. A very large gap between the anvil and the end of movable module
is available. The anvil and the end of movable module can press to each other
tightly and parallelly so that the pressed tissues distribute very uniformly. This
stapler also has a safety to avoid firing mistakenly.
Precautions:
This stapler is sterilized by γ-ray and is supplied for clinical use in a sterilized
packing.
Be sure to check the packing of this product carefully before use. Stop using it
if the packing bursts.
Haida Medical
3
This product is for ONE patient only, so it mustn’t be used again though
sterilized.
Make sure the product is within the period of validity (three years after
sterilized).It is strictly prohibited to use the product beyond the expiration date.
The sterilized products must be stored in a dry room with excellent ventilation
and without caustic gases.
Disposable linear stapler(HSN )semi-automatic
Type Staple Quantity
(PCS)
Suture Length
(mm)
Cartridge Color
Code
Remark
HSN-30H 13 33 Green Suitable for thick
tissue
HSN-30L 13 33 Blue Suitable for normal
tissue
HSN-45H 19 43 Green Suitable for thick
tissue
HSN-45L 19 43 Blue Suitable for normal
tissue
HSN-60H 25 61 Green Suitable for thick
tissue
HSN-60L 25 61 Blue Suitable for normal
tissue
Features:
Adjust the close height of the cartrige automatically according to the thickness
of the tissue.
Complete specifications apply to wide range.
Special transmission system and titanium parameter can make shape powerful,
and make perfect suture effect.
Open and close quickly, and operate it more conveniently
More close staple arrange.
Haida Medical
4
Function and Application
HSN disposable linear stapler can be used to conduct anastomoses through
firing into the tissue with two staggered rows of titanium staples instead of
using manual stitching. It can reduce operative time and bleeding, provide
ease of operation and improve the operation quality.
Disposable instrument avoid cross infection through the operation.
It is suitably for incomplete part and incision anastomoses.
2.Disposable linear cutter stapler
This stapler is suitable for transaction and resection of organic tissue, such as
Gastrectomy,Gynecology、Thoracic Surgery(Lobotomy of lungs)and Pediatric
Surgery (stomach, intestinal canal)
PRODUCT
CODE
STAPLE
HEIGHT
(MM)
SUTURE
THICKNESS
(MM)
CUTTING
LENGTH
(MM)
SUTURE
LENGTH
(MM)
NO. OF
TITANIUM
NAIL
55
60
60 HQ-60M 3.8 1.5
HQ-60H 4.5 2.0
75
80
80 HQ-80M 3.8 1.5
HQ-80H 4.5 2.0
95
100
100 HQ-100M 3.8 1.5
HQ-100H 4.5 2.0
Haida Medical
5
3.Disposable hemorrhoids stapler
Product
Code No. of Staples Knife Diameter Color Code
HYG-33 28 33 Black
HYG-34 32 34 Black
Features
Design of 32 nails to reduce hemorrhage after operation to the
maximum extent
Release ache after operation and speed up the period of recovery
Extra-large cartridge volume for more tissue.
Function
Cut and anastomose prolapsed mucosa tissue around the anal canal and
rectum.
Step to use
Using three clamps to support three points where prolapsed mucosa is less
and ectropion mucosa is light, then lead the anal retractor and anal speculum
into anus.
The anal retractor and anal speculum in anus will recover the prolapsed
hemorrhoid or the mucosa of the anal canal. Remove the anal retractor to let
the prolapsed mucosa be in the anal speculum.
Feed the sutural piece through the anal speculum .The suture should be over
3-4 cm far from the dentate line adjusted according to the degree of prolapse.
By turning the sutural piece, the suture around the whole anal canal can be
finished.
Feed the anastomat to make the nail retainer come to the upper end of the
purse, then knot the suture on the central rod of the device.
With the aid of the barbed needle, pull out the tail end of the suture from the
line-drawn hole of the anastomat.
Haida Medical
6
Draw the purse suture suitably to put the prolapsed mucosa into the cavity of
the head of the anastomat and close it. The red dial indication should entered
into the green zone and it is suggested to enter into the bottom of the green
zone. Open the safety, trigger and cut prolapsed mucosa in the cavity.
To help stop bleeding, keep the closed state of the anastomat for least 30
seconds after triggering. Turn out the anastomat counterclockwise gently for
2-3 turn, and return it back from the part of anal canal. And the operation is
finished.
Note
The suture should be over 4cm far from the dentate line. And the anastomatic
port should be over 2cm,because the low location will cause bleed after the
operation, while the high location cause unconspicuous effect. The lowest
position of sutured purse should under mucosa. If too shallow, it is easy to rive
the mucosa, and too deep, easy to hurt the sphincter.
The ligated line can’t be too tight, or it will affect pulling out the line-drawn.
After the operation, check the anastomotic port by means of the sutural piece.
If hemorrhagic spot is found, it should be sutured to stop bleeding
4. Disposable circular stapler
Features:
For disposal operation use, curb the possibility of cross infection, streamline
design is accordant with the human wagering and favorable to be used by
single hand.
You can adjust the closure height of nail room according to the thickness of
tissue. There are seven specifications to meet the requirements of different
cavity diameter.
There are six specifications to meet the requirement of different cavity
diameter.
Haida Medical
7
Product
Code No. of Staples External Diameter
Internal
diameter of
anastomosis
stoma
Color Code
HC-21 16 21 12 Orange
HC-24 18 24 15 Cyan
HC-26 20 26 16 White
HC-29 24 29 19 Blue
HC-31 26 31 22 Purple
HC-32 32 24 24 Green
Function and Application
Circular Stapler HC can easily and conveniently anastomose lumen organs by
firing into the tissues of alimentary canal two staggered (interior and exterior)
rings of titanium staples and cutting off inside tissue with the circular blades
simultaneously.
This stapler is suitably used for end-to-end and end-to-side tissue
anastomoses in alimentary canal organs such as esophagus, stomach, entera
etc., especially at the low recta and high esophagus not suitable for hand work.
It also can be used in the circular cutting operation of hemorrhoids.
Configuration
Circular Stapler HC mainly consists of anvil closure assembly and staples
firing assembly. Turn the adjusting knob clockwise, bring the anvil to move
horizontally to the circular blade assembly by lead screw, adjust the gap
between them to a proper scale (1.0mm~2.5mm, it can be seen from the firing
indicator window), then open the safety, squeeze the firing handle with a firm
and steady pressure to fire and anastomose.
In order to guarantee blood supply of the anastomosed tissue, the stapler can
adjust the closure gap (ranging from 1.0mm to 2.5mm) according to the
thickness of the tissue to be anastomosed. In addition, in order to avoid firing
beyond the range set beforehand, the stapler has a safety and the safety can
be opened only when the gap is between 1.0mm and 2.5mm.
For the sake of security, this instrument is designed to complete stitching and
cutting at the same time. The circular blades will automatically cut off otiose
tissue when the instrument is fired and circular anastomosis will be formed.
Precautions
Haida Medical
8
This stapler is sterilized by γ-ray and is supplied for clinical use in a sterilized
packing.
Be sure to check the packing of this product carefully before use. Stop using it
if the packing bursts.
This product is for One patient only, so it mustn’t be used again though
sterilized.
Make sure the product is within the period of validity (three years after
sterilized).It is strictly prohibited to use the product beyond the expiration date.
The sterilized products must be stored in a dry room with excellent ventilation
and without caustic gases.
Company in "hold world with virtue and self-reliance" enterprise culture, which
treats others with sincerity and sustained progress, and constantly improve the
quality of products, quality of service and professional level, together with our
clients to strive for excellence, create brilliant!
5.HJZ-Disposable circular stapler(Titanium)
It is suitable for anastomosis of gallbladder and intestine.
Product Code NO. of staples incision Dia.(mm) Dia.(mm) suture thicckness(mm)
HJZ-15A 12 8 15 1.0-2.5
For disposable operation use, curb the possibility of cross infection, streamline
design is accordant with the human engineering and favorable to be used by
single hand.
You can adjust the closure height of nail room according to the thickness of
tissue.
6. Reusable Surgical Stapler
HF Model linear stapler
Haida Medical
9
Technical parameters and Dimension
Product Code No. of staples Shape height Suture length(mm)
Hf-30 11 1.0-2.5 30
HF-60 21 1.0-2.5 60
HF-90 33 1.0-2.5 90
Function:
The linear Stapler is suitably used for incision anastomosis alimentary canal
surgery such as stomach and enteron.
Reusable linear stapler consist of changeable cartridge(disposable) and
reusable stapler body.
Application:
Gastrectomy of most of the stomach
Enteroectomy and clectomy
Reluctum low resection
HDG Model Hemorrhoids Stapler
Haida Medical
10
Model HGD PPH consists of changeable cartridge, attachment (disposable
and speculum, anal retractor sutural piece and barbed needle) and stapler
body (can be reused).
Technical parameters and Dimension
Product Code No. of staples Knife diameter(mm)
HDG-34 32 34
HG Model Circular Stapler
This stapler is suitably used for end-to-end and end-to-side tissue
anastomoses in alimentary canal organs such as esophagus, stomach, entera
etc., especially at the low recta and high esophagus not suitable for hand work.
Model HG Circular Stapler consists of changeable cartridge (disposable) and
stapler body (can be reused).
Technical parameters and Dimensions(mm)
Product
Code
No. of
staples
External
diameter
Shape
height
Internal
diameter(mm)
HG-26 20 26 1.0-2.5 16
Safe and convenient
Changeable cartridge(disposable)
Stapler body is reusable.
7. ENDO LINEAR CUTTER
Endo linear cutter (universal) Cartridge (STRAIGHT)
Haida Medical
11
DESCRIPTION
The ENDO LINEAR CUTTER STAPLER place two, triple-staggered rows of titanium
staples and simultaneously divides the tissue between the two, triple-staggered rows. The
size of the staples is determined by the selection of the 2.5 mm, 3.5 mm or 4.8 mm
STRAIGHT single cartridge The ENDO LINEAR CUTTER staplers will accommodate any
of the straight single use loading unit sizes that are available in the 30 mm, 45 mm and 60
mm lines.
When using the ENDO LINEAR CUTTER staplers with the 4.8 single use cartridge, it
must be inserted into a 15 mm trocar sleeve. The instrument may be reloaded and fired up
t0 25 times in a single procedure.
NOTE: This instrument can accommodate the 60-2.5, 3.5, 4.8 mm cartridges.
Technical parameters and dimensions
Name Product code sizes
EDNO LINEAR CUTTER HENDO-L /
CARTRIDGE (Straight single
use cartridge)
HENDO HENDO-60-4.8A, HENDO-
45-4.8A
APPLICATION
The Endo linear cutter staplers have applications in abdominal, gynecologic ,pediatric and
thoracic surgery for resection ,transection and creation of anastomosis.
IMPORTANT;
This device was designed, tested and manufactured for single patient use only. Reuse
or reprocessing of this device may lead to its failure and subsequent patient injury.
Reprocessing and/or resterilization of this device may create the risk of contamination
and patient infection. Do not reuse: reprocess or resterilize this device..
8. DISPOSABLE PURSE STRING INSTRUMENT
Haida Medical
12
I.Expected Application : Disposable purse string instrument is suitable for clinical
surgical purse string use.
II.Technical parameters and dimentions
mm
Item Suture length
(±5MM)
Cartridge
length(mm) No. of staples(pcs)
HYB-45 600 47 18
HYB-65 700 67 28
Ⅲ.Features:
1. Gently nip,a purse string formed
2. 2.Purse string and staples inside
3. 3.Reduce operation time
4. 4.Disposable, avoid cross-infection
9.Skin stapler
Type: HPF-35A
Material: stainless steel
Staples Formed: 7.3*4.0 & 5.3*3.3
Suitable for skin suture in kinds of surgical operation, it can decrease scar
effectively, the best substitutes goods of traditional suture.
Features:
1. For disposal operation use, avoid the possibility of cross infection
2. One-hand use, easy to operate. sew up rapidly and reliable
3. Seam is tidy and beautiful, small stitched wound, easy for healing would
4. Shorten operation time, decrease the work of doctors.
5. Removing stapler fast to reduce the pain for patient
10.disposable curved cutter stapler
Haida Medical
13
A. Function :
Disposable curved cutter stapler can be used to resect and conduct anastomoses
through firing into the tissues two staggered rows of titanium staples instead of
manual stiching ,I t can reduce operative time and bleeding ,provide ease of use
and improve the operation quality.
B. Application
The curved cutter stapler is suitably used for transaction, insection and
anastomosis in alimentary canal surgery such as stomach and enteron .
C. Technical parameters and dimensions:
NAME Product
code
Suture length Staple
height
Disposable curved cutter
stapler
HHQ-45A 45mm 4.5 mm
HHQ-45B 45mm 4.0 mm
Changzhou Haida Medical Equipment Co.,Ltd
http://www.haida-cz.com/en/index.asp
Tel:086+519-88671868