7/14/2019 Cfm Flowmeter Catalog
1/28
Industrial & PrecisionFlowmeters
For over 50 years, COX Flow Measurement has met the test ofendurance, which can only be achieved by manufacturing a qualityowmeter with unsurpassed repeatability and linearity. The COX
turbine owmeter is embedded in more military applications thanany other manufacturer. From this platform, COX launched products
into every liquid and gas application in the industry. Today, we offerthe highest quality turbine meters available with unmatched
calibration uncertainty.
COX products can be found in applications ranging from fuels,
demineralized water and chemicals, to cryogenic ow measurementof CO2. With a variety of end-ttings to mate with piping and an
array of electronics for signal processing, COX Flow Measurementprovides the right solution for demanding ow applications. Our
sales engineers stand ready to help you with your applicationsand our customer service team provides quality after-salesproduct support.
FM78587AS9100 and ISO 9001
COX Flow Measurement maintains an accredited
NVLAP Primary Standard Calibration Laboratory
CRYOGENIC FLUIDS
POWER GENERATION
BULK LOADING
FOOD PROCESSING
REFINING
A DIVISION OF
Proven Performance for Over 50 Years
-
7/14/2019 Cfm Flowmeter Catalog
2/28
The Company
COX Flow Measurement is a division of Badger Meter,
Inc. USA, based in Milwaukee, Wisconsin. With sales ofmore than $250 million, combined with the dedicationof more than 1,200 employees around the world,
Badger Meter has been a leading marketer andmanufacturer of ow measurement and control
devices since 1905.
COX Flow Measurement consists of COX Precision andIndustrial owmeters, Exact Flow high-accuracy dualrotor owmeters, and the prestigious Flow Dynamics
NVLAP (Lab Code 200668) accredited Primary StandardCalibration Laboratory. These companies complement
the best-in-class technology of Badger Meter.
COX Flow Measurement offers a variety of ow meteringproducts, signal conditioners, indicators and ow
computers, which provide compensation algorithms toachieve the ultimate accuracy in ow.
COX Flow Measurement maintains a competent NVLAPaccredited calibration facility, in accordance with the
U.S. Code of Federal Regulations (CFR, Title 15, Part 285)and encompassing the requirements of ISO/IEC 17025.
The ongoing NVLAP audits demonstrate COX FlowMeasurements excellence in maintaining quality
systems, test and calibration methods, andmeasurement traceability. In addition, all productsare manufactured with care and conformity to AS9100
and ISO 9001:2008 directives.
FM78587AS9100 and ISO 9001
2
COX Flow Measurement Provides:
1. Precision Turbine Meters
2. Primary Standard Calibration Service
3. Flow Transfer Standard Calibration Systems
4. Primary Standard Calibrators
5. OEM Manufacturing
Badger Meter Milwaukee, Wisconsin COX Flow Measurement Scottsdale, Arizona
-
7/14/2019 Cfm Flowmeter Catalog
3/28
3
FLOWMETER CONFIGURATIONS......................................................................................4
COX HIGH-ACCURACY PRECISION AND INDUSTRIAL FLOWMETERS ...........................6
CX FLOW RANGE TABLE ................................................................................................7
CX STANDARD METER MATERIALS................................................................................7
CX HOUSING PRESSURE RATINGS .................................................................................8
FLANGE PRESSURE RATINGS.........................................................................................8
CX MODEL NUMBERS ...................................................................................................9
TURBINE FLOWMETER DIMENSIONS ...........................................................................10
CX AN/NPT TURBINE FLOWMETER DIMENSIONS..........................................................10
CX SA TURBINE FLOWMETER DIMENSIONS .................................................................10
FLANGED TURBINE FLOWMETER DIMENSIONS............................................................11
CLF LOFLO TURBINE METER DIMENSIONS ...............................................................11
LOFLO SERIES.............................................................................................................12
LOFLO MODEL NUMBER AND FLOW RANGE TABLE......................................................13
EXACT SERIES DUAL ROTOR FLOWMETERS...............................................................14
EXACT SIZE AND FLOW RANGE....................................................................................15
EXACT MODEL NUMBERS............................................................................................16
EXACT AN TURBINE FLOWMETER DIMENSIONS ...........................................................17
EXACT DUAL ROTOR TURBINE CONCEPT .....................................................................18
FLOWMETER CALIBRATION CODES .............................................................................18
CALIBRATION CAPABILITY ............................................................................................19
ELECTRONIC PRODUCTS ...............................................................................................20
SIGNAL CONDITIONERS...............................................................................................20
INDICATOR DISPLAYS..................................................................................................20
PANEL MOUNT FLOW COMPUTERS .............................................................................21
FLOW COMPUTERS, METER MOUNTED & REMOTE......................................................21
FLOW STRAIGHTENERS...............................................................................................22
INSTALLATION.............................................................................................................22
FLOW TRANSFER STANDARDS ....................................................................................23
FLOW DYNAMICS PRIMARY STANDARD PD CALIBRATORS ......................................24
FLOW CALIBRATORS...................................................................................................24
OEM SEMI-AUTOMATIC CALIBRATORS ........................................................................26
CALIBRATOR CHECK STANDARDS ...............................................................................26
MANUFACTURING CELLS............................................................................................27
Table of Contents
-
7/14/2019 Cfm Flowmeter Catalog
4/28
FLOWMETER CONFIGURATIONS
EXACT SERIES END-FITTING OPTIONSDUAL ROTOR
CX SERIES END-FITTING OPTIONSSINGLE ROTOR
Flanged Series Pipe Fittings
150# to 600#
NPT Series Pipe Fittings
From 1/4" to 2"0.25 to 310 GPM
AN Series Pipe Fittings
37" FlareFrom 1/4" to 2"
0.25 to 310 GPM
Tri-Clover Pipe Fittings
From 1/4" to 2"
0.25 to 310 GPM
4
LoFlo Series AN Pipe Fittings
1/2", 37" Flare
0.007 to 1.25 GPM
Wire LeadsAmplied Pickoff
MS
Amplied Pickoff
Wire LeadsMagnetic Pickoff
Sine WaveMV Signal
Amplied
Square Wave
AN Series Pipe Fittings
37" FlareFrom 1/4" to 2"
0.25 to 310 GPM
Flanged Pipe Fittings
From 1/4" to 4"0.025 to 1,500 GPM
Housing
Wire Termination
SineRF C
-
7/14/2019 Cfm Flowmeter Catalog
5/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
FLOWMETER CONFIGURATIONS
METER MOUNTEDELECTRONICS
PANEL MOUNTEDELECTRONICS
CUSTOMERSCONTROL SYSTEM
5
Meter Mounted
Model: EC80 Flow Computer
Enclosure: Explosion-proof cast aluminumPower: 24 VDC Nominal
Inputs: Single/Dual Rotor freq., RTDOutputs: 2 freq., 2 analog (4-20 mA, 0-10 VDC)
Digital Outputs: 0-5 V TTL, RS485
Remote Mounted
Model: 4080 Flow Computer
Enclosure: Aluminum with mounting angeNEMA 4
Power: 24 VDC NominalInputs: Single/Dual Rotor freq., RTD
Outputs: 2 freq., 2 analog (4-20 mA, 0-10 VDC)Digital Outputs: 0-5 V TTL, RS485
Model: RT112
Rate & Total Indicator 15-point linearization
Power: Loop or battery-powered, 8-24 VAC/DC or 115-230 V AC power supply
Input: Sine wave, pulse, 4-20 mA or 0-10 VDCOutput: Scaled 4-20 mA or 0-10 VDC
Panel Mounted Flow Computer
Model: FC30 Flow Computer
Liquid and gas applicationsBatching and temperature viscosity corrections
Power: 110/220 VAC and 12/24 VDC
Input: Single/Dual Rotor freq., RTD
Output: Pulse, RS232 and 485
Panel Mounted Indicator
Model: CUB5Rate or Total indicator up to 8 digits
Programmable rate scaling and decimalpoint placement
Power: 9-28 VDCEnclosure: NEMA 4X/IP65Input: 4-20 mA and RTD
Customers Data Acquisition System
Not sold by COX Flow Measurement
Customers Control System
-
7/14/2019 Cfm Flowmeter Catalog
6/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
PROVEN PERFORMANCE FOR OVER 50 YEARS
COX HIGH-ACCURACY PRECISION AND INDUSTRIAL FLOWMETERS
COX Flow Measurement has been the icon
of turbine owmeters since its inception.The installation base is a testimony tocustomers who have discovered the
performance and longevity of COX turbinemeters and associated electronics.
DESCRIPTION
COXs superior performance is creditedto the axial helical rotor design, whichenhances linearity, repeatability and
speed-of-response and reduces pressuredrop. A single-bearing design minimizes
friction and delivers linearity beyond that
of the standard 10:1 range. This bearingsystem also extends the repeatable rangeto 60:1 on small meters and up to 150:1on large meters.
In addition, COX Flow Measurement offers
the EC80 ow computer, which willlinearize the meter within 0.1% linearityover the entire repeatable range. This ow
computer offers temperature and pressurecompensation with multiple outputs for
frequency and analog in engineering units.
COX precision owmeters utilize animproved, extended 6-vane support toreduce uid swirl from entering the rotor.
Ceramic ball bearings are standard forimproved durability. The 316 SS housing
exceeds the pressure ratings of the AN
(MS) ttings. Hex or square housings makeit easy for tightening the threaded ttingsduring installation and removal.
Calibrator Uncertainty 0.05% of reading
Repeatability 0.02% of reading
Linearity 0.5% of reading
With Electronic Linearizer 0.1% of reading
Frequency Output (maximum) 500 to 1500 Hz standard
Pressure Rating See charts
Output Signal 0-10 V (square wave pulse)
Response Time 2-3 mS or better
PERFORMANCE SPECIFICATIONSADVANTAGES
Superior linearity
Exceptional repeatability
Wide ow range
Fast response to rate changes
316 SS housings standard Ceramic bearings
4-week delivery or less on standard models
Primary Standard Calibrations traceable to NIST & NVLAP(Lab Code 200668) accredited
6
COX Flow Measurement continues to improve
meter performance by offering long-life ceramic
bearings and unsurpassed primary standard
calibration uncertainties of 0.05% of reading.
Coupled with an advanced EC80 ow computer,
these owmeter systems provide fully
compensated precision ow measurements.
-
7/14/2019 Cfm Flowmeter Catalog
7/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
CX FLOW RANGE TABLE
Model CXStd. Linear
Std.P Repeatable
RangeLinear
@ Range Freq. @ P @
MeterMeter Size Flow
10:1
Repeatable
Max. Repeatable
Sizein 1/16"
GPM RatioFlow
GPMFlow Ratio
Flow Flow Ratio
InchesRatio
1/4" 8-4 0.25 - 3.0 12:1 3.5 0.05 - 3.0 60:1 6.5
3/8" 8-6 0.50 - 6.0 12:1 4.5 0.06 - 6.0 8.5
1/2" 8 0.75 - 9.5 12.6:1 6.0 0.09 - 9.5100:1
8.5
5/8" 10 1.25 - 15.5 12.5:1 5.0 0.16 - 15.5 9.0
3/4" 12 2.50 - 30 12:1 5.0 0.30 - 30 1500 Hz 9.0
1" 16 5.0 - 65 13:1 5.0 0.45 - 65 9.0
1" 20 7.5 - 95 12.6:1 5.5 0.65 - 95150:1
8.5
1" 24 12.5 - 155 12.4:1 6.0 1.05 - 155 9.0
2" 32 25 - 310 12.4:1 6.5 2.10 - 310 9.0
3" 48 53 - 800 15:1 10.0 20 - 800 25:1 45 Hz 10.0
4" 64 100 - 1500 15:1 10.0 50 - 1250 25:1 20 Hz 10.0
Standard ranges = 10-point calibration and extended ranges = 20-point calibrationMeter linearity was developed using MIL-C-7024C, Type 2 at 80F
Helical Rotor Material: 17-4 SSBall Bearing: CeramicMeter Body Material: 316 SS
Note: Other materials available upon request.
Lightweight helical rotors provide 3 mS, or less, speed-of-response and extended linear ranges. The helical bladeprole transfers energy more efciently, reducing bearing wear, pressure drop and their associated cost.
Industrial applications will benet from using ceramic ow-through ball bearings. This ceramic bearing system is
extremely versatile and the recommended bearing for most applications, including cryogenics. This superior low-friction bearing outperforms journal bearings and extends the usable range of the turbine owmeter.Whatever the uid media, COX Flow Measurement has a proven solution.
CX STANDARD METER MATERIALS
Lightweight helical rotor
Versatile ceramic bearing for water,cryogenics and hydrocarbons
7
-
7/14/2019 Cfm Flowmeter Catalog
8/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
CX HOUSING PRESSURE RATINGS
FLANGE PRESSURE RATINGS
The type of end-tting used may have a lower pressure rating than the AN owmeter housing
Maximum non-shock allowable working pressure in psig at 100F or less
Alloy Pressure Class
150 Flg 300 Flg 600 Flg 900 Flg 1500 Flg 2500 Flg
StainlessSteel 316 275 720 1440 2160 3600 6000A-181
8
-
7/14/2019 Cfm Flowmeter Catalog
9/28
Proven Performance for Over 50 Years
CX MODEL NUMBERS
Model Number Format for AN, NPT, SA and Flange End-Fittings
CX 2 NP C2 CB XXX
COX Model Size AN End- PickoffBearing
3-DigitNumber (inches) Sizes Fittings Description Special
CX 1/4" 8-4 AN=37Flare C1=Carrier MS 3 Pin CB=CeramicBall
3/8" 8-6 NP=NPT SB=SST BallMale
1/2" 8 SA=Sanitary C3=Car MS RTD5/8" 10 F1=150# Flng SS C4=Car NPT RTD
3/4" 12 F3=300# Flng SS C5=Car MS RTD IS
1" 16 F6=600# Flng SS C6=Car NPT RTD IS
1" 20 C1=F150C M1=Mag MS
1" 24 C3=F300C M2=Mag NPT
2" 32 C6=F600C M3=Mag MS RTD
2" 40 M4=Mag NPT RTD
3" 48 M5=Mag MS RTD IS
4" 64 M6=Mag NPT RTD IS
Refer to Electronic Products Section for a complete review of all electronic signal conditioners, indicators and ow computers.
MODEL NUMBER EXAMPLES:
CX1/2AN-C3CB-XXX
CX2F1-C2CB-XXX
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
9
Used toidentifyspecial
congurations
Only
Available
in FlangeSizes
C2=Carrier NPTthreaded with leads
-
7/14/2019 Cfm Flowmeter Catalog
10/28
TURBINE FLOWMETER DIMENSIONS
CX AN/NPT TURBINE FLOWMETER DIMENSIONS
CX SA TURBINE FLOWMETER DIMENSIONS
ANCOX A A B C Tube End-
Model NPT AN Max Size Fitting
CX-1/4 2.7 (69) 2.45 (62) 1.12 (28) n 3.43 (87) 1/2" (127) 8
CX-3/8 2.7 (69) 2.45 (62) 1.12 (28) n 3.46 (88) 1/2" (127) 8
CX-1/2 2.7 (69) 2.45 (62) 1.12 (28) n 3.52 (89) 1/2" (127) 8
CX-5/8 N/A 2.72 (69) 1.25 (32) n 3.59 (91) 5/8" (15.9) 10
CX-3/4 3.29 (84) 3.25 (83) 1.25 (32) n 3.65 (93) 3/4" (19) 12
CX-1 3.78 (96) 3.56 (90) 1.63 (41) 3.77 (96) 1" (25.4) 16
CX-1 4.23 (107) 4.06 (103) 1.88 (48) 3.89 (99) 1" (31.7) 20
CX-1 4.67 (119) 4.59 (117) 2.25 (57) 4.01 (102) 1" (38) 24
CX-2 5.89 (150) 6.06 (154) 2.75 (70) 4.24 (108) 2" (51) 32
10
n Square Body Hex Body
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for yourapplication. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
Note: Housing dimensions are in inches (mm). All dimensions are for reference only. Actual dimensions
should be obtained from the factory.
Note: Housing dimensions are in inches (mm). All dimensions are for reference only. Actual dimensions
should be obtained from the factory.
COX A B C Tube Clamp CodeModel Max Size Size
CX-1/4 SA 3.56 (90) 0.984 (24.99) 3.43 (87)1/2" (127)
CX-3/8 SA 3.56 (90) 0.984 (24.99) 3.46 (88) 3/4" (19) T1
CX-1/2 SA 3.56 (90) 0.984 (24.99) 3.52 (89) 3/4" (19)
CX-5/8 SA 3.56 (90) 1.984 (50.39) 3.59 (91)
CX-3/4 SA 3.56 (90) 1.984 (50.39) 3.65 (93) 1" (25.4)
CX-1 SA 3.56 (90) 1.984 (50.39) 3.77 (96) 1" (38) T2
CX-1 SA 4.59 (117) 1.984 (50.39) 3.89 (99)
1" (38)CX-1 SA 4.59 (117) 1.984 (50.39) 4.01 (102)
CX-2 SA 6.06 (154) 2.516 (63.91) 4.24 (108) 2" (51) 2" (51) T3
-
7/14/2019 Cfm Flowmeter Catalog
11/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
11
TURBINE FLOWMETER DIMENSIONS
FLANGED TURBINE FLOWMETER DIMENSIONS
B B BCOX Model A F1=150 lb F2=300 lb F3=600 lb
Flange Flange Flange
CX-1/4 F_ 5 (127) 3.5 (89) 3.75 (95) 3.75 (95)
CX-3/8 F_ 5 (127) 3.5 (89) 3.75 (95) 3.75 (95)
CX-1/2 F_ 5 (127) 3.5 (89) 3.75 (95) 3.75 (95)
CX-5/8 F_ 5.5 (140) 3.5 (89) 3.75 (95) 3.75 (95)
CX-3/4 F_ 5.5 (140) 3.87 (98) 4.62 (117) 4.62 (117)
CX-1 F_ 5.5 (140) 4.25 (108) 4.87 (124) 4.87 (124)
CX-1 F_ 6 (152) 4.62 (117) 5.25 (133) 5.25 (133)
CX-1 F_ 6 (152) 5 (127) 6.12 (156) 6.12 (156)
CX-2 F_ 6.5 (165) 6 (152) 6.5 (165) 6.5 (165)
CX-2 F_ 7 (178) 7 (178) 7.5 (191) 7.5 (191)
CX-3 F_ 10 (254) 7.5 (191) 8.25 (210) 8.25 (210)
CX-4 F_ 12 (305) 9 (229) 10 (254) 10.75 (273)
ANSI raised-face integral anges
CLF - LOFLO TURBINE METER DIMENSIONS
Note: Housing dimensions are in inches (mm). All dimensions are for reference only. Actualdimensions should be obtained from the factory.
Note: Housing dimensions are in inches (mm). All dimensions are for reference only. Actual dimensionsshould be obtained from the factory.
COX Model Tube Size A B C Max AN Size
CXLF-8-6 3/8" (9.5) 2.22 (56.4) 1 (25.4) 4.25 (108) 6
-
7/14/2019 Cfm Flowmeter Catalog
12/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
12
PROVEN PERFORMANCE FOR OVER 50 YEARS
LOFLO SERIES
Repeatability 0.25%
Frequency Output 1500-1800 Hz
Pressure Rating 6000 psi
Response Time 20-30 mS
Body Construction 316 SST
End Fittings -6 AN (MS)
PERFORMANCE SPECIFICATIONSADVANTAGES
Low-friction ceramic ball bearings
Suitable for water, hydrocarbons and cryogenic service 17-4 helical rotor
Compact size (2.22" face dimension)
Bearings are the key factor in performance whenmeasuring low ow. That is why COX Flow
Measurement uses ceramic ball bearings, which
are near perfect in roundness within 10 millionths
of an inch variation. This means lower friction and
less vibration, which equals superior repeatability.
The COX LoFlo Series is a robust axial turbine owmeter with
exceptional repeatability of 0.25% of reading. When paired with theEC80 Flow Computer, the calibration data is linearized to within 0.1%of reading, allowing for precision ow measurement over the entire
usable range of the meter. COX LoFlo Series owmeters are notposition-sensitive and can be mounted in any piping orientation.
The custom long-life, ceramic low-friction ball bearing system used inthe COX LoFlo Series meets the demands of water, hydrocarbons and
cryogenic uids. Capable of measuring ows as low as 0.006 GPM(0.024 LPM), this meter is an ideal solution for a multitude of
applications. Typical uses include fuel injection productionsystems, blending of costly chemical additives, onboard fuel
consumption, refrigerants, dye injections, and more.
Ceramic ball bearings have much less ction than journal
bearings and provide a wider measureable ow range with superiorrepeatability. The COX LoFlo Series is designed to be rugged and
repeatable with the assurance of the most accurate calibrationprovided on our positive displacement primary standard calibrators.
-
7/14/2019 Cfm Flowmeter Catalog
13/28
13
Proven Performance for Over 50 Years
PROVEN PERFORMANCE FOR OVER 50 YEARS
LOFLO MODEL NUMBER AND FLOW RANGE TABLE
CLF6-000 0.007 - 0.075 2.85 - 28.5 0.006 - 0.075 2.2 - 28.5 3/8" 1800 20.0
CLF6-00 0.012 - 0.125 4.75 - 47.5 0.009 -0.125 3.4 - 47.5 3/8" 1800 12.0
CLF6-0 0.025 - 0.25 9.50 - 95.0 0.014 - 0.25 5.4 - 95.0 3/8" 1800 4.5
CLF6-1 0.050 - 0.50 19.0 - 190 0.023 - 0.50 8.8 - 190 3/8" 1500 4.0
CLF6-2 0.075 - 0.75 28.5 - 285 0.037 - 0.75 13.2 - 285 3/8" 1500 4.5
CLF6-3 0.125 - 1.25 47.5 - 475 0.06 - 1.25 22 - 475 3/8" 1500 7.0
Standard ranges = 10-point calibration and extended ranges = 20-point calibration* Pressure drop calculation based on liquid with a specic gravity of 0.76.
COX
ModelNumber
Std 10:1 Range
Magnetic Pickoff
Extended Range
Carrier Pickoff
*P @
Max FlowRange(PSI)
Tube Size(inches)
Max.
Frequency(Hz)
GPM Lbs. / Hour GPM Lbs. / Hour
English Units
CLF6-000 0.27 - 0.284 1.29 - 12.9 0.024 - 0.284 0.998 - 12.9 3/8" 1800 1.40
CLF6-00 0.045 - 0.473 2.15 - 21.5 0.034 - 0.473 1.54 - 21.5 3/8" 1800 0.84
CLF6-0 0.095 - 0.946 4.31 - 43.1 0.053 - 0.946 2.45 - 43.1 3/8" 1800 0.32
CLF6-1 0.189 - 1.89 8.62 - 86.2 0.087 - 1.89 3.99 - 86.2 3/8" 1500 0.28
CLF6-2 0.284 - 2.84 12.9 - 129 0.140 - 2.89 5.99 - 129 3/8" 1500 0.32
CLF6-3 0.473 - 4.73 21.5 - 215 0.227 - 4.73 9.98 - 215 3/8" 1500 0.49
Standard ranges = 10-point calibration and extended ranges = 20-point calibration
* Pressure drop calculation based on liquid with a specic gravity of 0.76.
COX
Model
Number
Std 10:1 Range
Magnetic Pickoff
Extended Range
Carrier Pickoff*P @
Max FlowRange
(Kg/cm2)
Tube Size
(inches)
Max.
Frequency
(Hz)Lit. / Min. Kg. / Hour Lit. / Min. Kg. / Hour
Metric Units
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
-
7/14/2019 Cfm Flowmeter Catalog
14/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
14
PROVEN PERFORMANCE FOR OVER 50 YEARS
EXACT SERIES DUAL ROTOR FLOWMETERS
Calibration Uncertainty 0.05% of reading
Repeatability 0.02% of reading
Linearity (with linearizer) 0.01% of reading
Process Temperature -450F (-270C) to 300F (150C) standard
Operating Pressure Up to 30,000 PSIG depending on size and end-ttings
Pressures Drop 14 PSID at max. ow rate @ 1.2 cStk
Bearings Ceramic standard (water & hydrocarbons)
PERFORMANCE SPECIFICATIONSADVANTAGES
No need for ow straighteners
Enhanced performance due to helical rotors
Superior absolute accuracy
Excellent repeatability Wider operating ow range
Extended UVC ow range
Integral pickoff impervious to vibration
NVLAP calibration uncertainty
COX Flow Measurement offers the pinnacle of
turbine owmeter performance. The Dual Rotoris NISTs golden meter for round robin
testing. Its use around the world for primary
standard calibrator correlation tests is proof of
performance.
COX Flow Measurement offers proven owmetering solutions for the most demanding
aerospace, automotive, industrial and OEMapplications. The Exact Series Dual RotorTurbine Flowmeter is the worlds most precise
meter of its kind, providing extended rangeperformance not obtainable with traditional
single rotor designs.
DESCRIPTION
The Exact Series Dual Rotor Turbine Flowmeterprovides an extended ow range capability,
which often eliminates the need for manifoldsystems and thus simplies installation and
lowers costs. The meters exceptionalperformance, enabled by the innovative dual
rotor conguration, enhances UVC curves andextends the usable measurement ow range.
With the Exact Series Dual Rotor TurbineFlowmeter (Standard Model CDX/CDL), ow
straighteners are not required to controlprocess uid swirl, as the dual rotor systemcancels out the rotor acceleration effect. With
ow straighteners, bearing diagnostics can bedetermined by monitoring the ratio of the rotors
to detect wear or cleanliness. The Exact Seriesmeters also utilize a unique pickoff system,
which is impervious to vibration and minimizes
space. This allows for direct coupling ofelectronics on a robust mount having a lower
prole. Both integral and remote electronicsare available to process the signal output.
Exact Series Dual Rotor technology is ideal for
a wide range of applications. The meter isdesigned for bi-directional ow and high-shockenvironments. It utilizes a robust bearing
system having dual ceramic bearings on eachrotor with the internals securely locked in place,
resulting in excellent repeatability. The dualrotor meter allows for installation in applications
that do not have space for ow straightenerswithout loss of measurement accuracy.Pressures of up to 30,000 psig can be
contained, while compensating for viscositychanges using integrated pressure sensors.
WORLDS MOST PRECISE STANDARD & INDUSTRIAL TURBINE FLOWMETERS
DL MS connector for
remote ow computer
DX explosion-proof
with ow computer
-
7/14/2019 Cfm Flowmeter Catalog
15/28
15
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
PROVEN PERFORMANCE FOR OVER 50 YEARS
1/4" 8-4 0.025 - 3.0 0.095 - 11.4 120:1 30:1 30000 33000
3/8" 8-6 0.035 - 6.0 0.132 - 22.7 171:1 35:1 15000 16500
1/2" 8 0.040 - 10 0.151 - 37.8 286:1 40:1 9480 10440
5/8" 10 0.045 - 16 0.170 - 60.5 355:1 45:1 6000 6375
3/4" 12 0.08 - 30 0.302 - 113.5 375:1 50:1 3640 4000
1" 16 0.15 - 65 0.378 - 246 433:1 60:1 1680 1846
1" 20 0.25 - 95 0.946 - 359.6 380:1 60:1 1149 1263
1" 24 0.35 - 155 1.324 - 586.7 443:1 60:1 705 774
2" 32 0.60 - 310 2.27 - 1173.4 517:1 60:1 242 266
2" 40 1.0 - 500 3.78 - 1892.7 500:1 60:1 132 145
3" 48 2.0 - 800 7.57 - 3028 400:1 60:1 45 50
4" 64 5 - 1500 18.9 - 5678 300:1 60:1 20 22
Meter Size(inches)
Meter Sizein 1/16" Rotor A Rotor B
Flow Range @ 1 cStk S.G. = 1UVC
TurndownRange
1 cStk
Turndown
range1 cStk
Typical K-Factor Pulses/Gallon
GPM LPM
Model CDX/CDL
EXACT
SIZE AND FLOW RANGE TABLE
STANDARD METER MATERIALS
-
7/14/2019 Cfm Flowmeter Catalog
16/28
PROVEN PERFORMANCE FOR OVER 50 YEARS
16
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
CDL=LowProle MS 1/4" 8-4 AN CB-Ceramic Ball R = RTDConnector
CDX=Explosion-Proof
Spud 3/8" 8-61/2" 08 F1=F150S
5/8" 10 F3=F300S
3/4" 12 F6=F600S
1" 16
1 20
1 24
2" 32
Flange 2 40
sizes 3" 48
only 4" 64
ExactModel Number
Size(inches)
ANSizes End-Fittings Bearing
TemperatureSensor 3-Digit Special
EXACT MODEL NUMBERS
Used to
identify
special
congurations
MODEL NUMBER EXAMPLES: CDX3/4-F1-CB-R-XXX and CDL1AN-CB-R-XXX
Bearings are the most critical component of a turbine owmeter in terms of both repeatability of the meter
output and the security of the calibration over time. This is why all COX Flow Measurement turbine meters useceramic ball bearings. There are several advantages in using ceramic material:
Ceramic can be used in non-lubricating uids Ceramic is non-corrosive and heat-tolerant, making it ideal for water or hydrocarbons
Ceramic offers near perfect roundness, minimizing vibration Ceramic is harder and measures RC 75-80 as compared to SST at RC58-65
Ceramic is 50% lighter than SST, extending the life of the bearing
All the above attributes reduce heat, providing ve times more wear resistance. Ultimately, this preserves the
calibration of the meter, while being more tolerant to particulates.
CDL 8-4 AN CB R XXX
-
7/14/2019 Cfm Flowmeter Catalog
17/28
17
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
PROVEN PERFORMANCE FOR OVER 50 YEARS
EXACT AN TURBINE FLOWMETER DIMENSIONS
Exact SeriesModel Tube Size A B A AN
Number (inches) AN AN Flange End-Fitting
CXL DualRotor, MSConnector
CDX DualRotor,
Explosion-Proof
1/4" 2.75 (70) 0.87 (20.1) 8
3/8" 2.75 (70) 0.87 (20.1) 8
1/2" 2.75 (70) 0.87 (20.1) 8
5/8" 2.92 (74) 1.00 (25.4) 10
3/4" 3.25 (83) 1.37 (34.8) 12
1" 3.56 (91) 1.50 (38.1) 5.50 (140) 16
1" 4.06 (103) 1.88 (47.7) 6.00 (152) 201" 4.59 (117) 2.00 (50.8) 6.00 (152) 24
2" 6.06 (154) 2.62 (66.5) 6.50 (165) 32
2" N/A 7.00 (178) N/A
3" N/A 10.00 (254) N/A
4" N/A 12.00 (305) N/A
Note: Housing dimensions are in inches (mm). All dimensions are for reference only.
Actual dimensions should be obtained from the factory.
-
7/14/2019 Cfm Flowmeter Catalog
18/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
18
FLOWMETER CALIBRATION CODES
Standard Calibration Codes
Model # # of Cal Points Fluids Viscosity Qty. Comments
10 = 10 calpoints
S = Solvent 1 = 1 viscosity
20 = 20 calpoints B = Oil Blend 2 = 2 viscosities
W = Water 1 cStk 3 = 3 viscosities
NOTE: 1. Calibrations are performed on primary standard calibration equipment operating in aNVLAP-accredited facility with an uncertainty of 0.5% of reading.
2. Solvent ranges from 1 to 1.14 cStk = MIL-C-7024C, Type 2 @ 80F.
3. Blends are a mixture of oils and solvent to obtain a specied viscosity.
All dual rotor metersmust use the EC80 FlowComputer to sum rotorfrequencies and linearizethe output to 0.1% ofreading.
PROVEN PERFORMANCE FOR OVER 50 YEARS
EXACT DUAL ROTOR TURBINE CONCEPT
1. Unconditioned ow enters owmeter.
2. Straightening vanes smooth the ow as itenters the rst rotor.
3. Flow transfers momentum to the rst rotor,making it spin counterclockwise. Flow then
exits rotor, with a clockwise spin.
4. Flow enters second rotor with a nearlyperpendicular angle of attack, thereby
transferring additional momentum to thesecond rotor. This additional momentum
results in greatly extended turndown.
5. Flow exits owmeter.
6. Dual pickoffs transmit the rotor frequency
signal to remote instrumentation.
NOTE: The ratio of both pickoff frequencies is
used for bearing diagnostics.
Blue is the fluid flow
Orange is the rotor rotation
CAL
__ __ __
(Meter Size)
-
7/14/2019 Cfm Flowmeter Catalog
19/28
19
COX Flow Measurement is
a participant in the NIST
round robin prociency
tests intended to eliminate
calibrator bias. This goes
beyond traditional NIST
traceability and provides
correlation data using
NIST owmeter artifacts tocompare directly with
NIST calibrations.
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
PROVEN PERFORMANCE FOR OVER 50 YEARS
Calibrations are performed at COX Flow Measurement, a NVLAP (Lab Code 200668) accredited facilityusing Primary Standard Calibrators producing 0.05% of reading uncertainty.
Customers can select from a variety of calibrations to enhance the accuracyof the ow measurement reading. Often, manufacturers perform water
calibrations and then use a correction factor. This can be misleading, as thecalibration curve will vary in more viscous uids. COX Flow Measurement
avoids calibration shifts by using the actual uid viscosity in the calibrator todevelop the calibration curves. Multiple calibrations can be provided to form
a single Universal Viscosity Curve, which adjusts the frequency/viscosityrelationship to match the actual temperature of the known uid.
Liquid Flow Measurement: Primary Liquid Calibrators:
0.0025 to 1,500 GPM hydrocarbon Uncertainty: 0.025% to 0.05% of reading
0.75 to 1,000 centistokes viscosity Repeatability: 0.012% of reading
0.01 to 300 GPM water
Gas Flow Measurement: Primary Gas Calibrators:
0.001 to 3,500 SCFM in air Uncertainty: 0.20% to 0.25% of reading
0.001 to 400 SCFM inert or ammable gases Repeatability: 0.10% of reading
Gas correlations for toxic gases Partial vacuum to 500 PSIA
CALIBRATION CAPABILITY CALIBRATOR UNCERTAINTY
100 Cubic Foot Gas PrimaryStandard Bell Prover
PDCL-400 Liquid PrimaryStandard Calibrator
CALIBRATION CAPABILITY
-
7/14/2019 Cfm Flowmeter Catalog
20/28
20
SIGNAL CONDITIONERS
INDICATOR DISPLAYS
Carrier Pickoff/AmplierDescription:
COX Carrier Pickoff/Amplier extends the usable range ofthe owmeter by eliminating magnetic drag on the rotor.
This enhances not only the range, but also the linearity atlow ow. The modulated carrier frequency is amplied and
conditioned to provide a square wave pulse output, capableof transmitting up to 100 ft.
Specications:
Input Power: Min 11.0 VDC; Max 30.0 VDC
Input Current Standard: 15 mA Output Voltage: 0 to 10 VDC Temperature Range: -40F to 248F
(-40C to 120C)
Digital Display, Panel Mount
Description:
The indicator toggles manually or automatically, to view eitherrate or total and displays up to 8 digits with separate scaling
and decimal point placement. Programmable update times,front panel reset and dual counters make this miniature digitalindicator ideal for owmeters with pulse outputs. The LCD
display, with letter height of 0.46", is provided in positivereective or negative transmissive with yellow/green or red
LED backlighting, to meet your visual requirements.
Specications:
Input Power: 9 to 28 VDC Non-volatile memory
NEMA 4X/IP65 front bezel Operating Temperature:
-31F to 167F (-35C to 75C)
depending on intensity leveland display color
Display response rate indicator has low or high update times Frequency: Min 0.01Hz Max 20 KHz
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
Description:The RT112 has a large, UV-resistant display of 0.67" (17 mm)
with digits of 0.31" (8 mm), which can be set to show owrates or totals in selectable engineering units. Linearization
is standard with up to 15 data points of calibration andselectable output signal options. The linearized accumulatedtotal can register up to 11 digits and is backed up in EEPROM
memory every minute. All settings are safely stored inEEPROM memory in the event of a sudden power failure.
The display enclosures are water-tight, conforming to NEMA 4X/
IP67, and available in aluminum and molded congurations.An intrinsically safe option is available conforming to ATEX,
IECEx, FM and CSA. The unit has a maximum operatingtemperature of 158F (70C). The RT112 can be mounteddirectly on the owmeter, wall mount, exterior panel mount or
pipe stand.
Specications: Input Power: Long-life lithium
battery - 110/230 VAC 50/60 Hz
- 8/24 VAC/DC, 10 watts max. 4-20 mA loop-powered
Auto Backup: All settings andrunning totals
Operating Temperature: -22F to
178F (30C to 80C) Update Rate: User-denable from 10 times/sec 30 secs
Linearization: 15 data points Signal Output: Rate = 4-20 mA, 0-10 VDC, Total = scaled pulse
Display: Rate & Total with selectable on-screen engineering units Conguration Settings: Front panel input with simple operator
menu. Pass-code protected.
Modbus Communication: RS232/RS485
RT112 Flow Rate Indicator/Totalizer, with Linearization
PROVEN PERFORMANCE FOR OVER 50 YEARS
ELECTRONIC PRODUCTS
-
7/14/2019 Cfm Flowmeter Catalog
21/28
21
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
PROVEN PERFORMANCE FOR OVER 50 YEARS
Series FC30 Flow Computer, Panel Mount
Description:
COX FC30 Flow Computer services both liquid and gas appli-cations. The FC30 has features such as: batching, 40-point
owmeter linearization tables, temperature viscosity correctionusing Strouhal/Roshko advanced linearization methods, and
multiple ow and control inputs. Relay outputs are independ-ently assignable for alarms and general purpose warnings.
The FC30 has serial communications, both RS232 and RS485,and isolated analog and pulse outputs.
The display has two lines of 20 characters (0.3" in height),with blue VFD or backlit LCD. During start-up, there is a service
or test mode to check out the system by monitoring inputs andexercising outputs, and printing system setup. The unit is CE-
compliant, UL/CUL listed, and housed in a DIN enclosure madeof ame-retardant plastic.
Specications:
Input Power: 110/220 VAC 50/60Hz, 12/24 VDC, 300 mA max.
Operating Temperature: 32F to122F (0C to 50C)
Accuracy: 0.01% FS at 20C Resolution: 16-bit
Update Rate: 1 update/sec min. Linearization: 40-point table, UVC table or Strouhal/Roshko
computations
Temperature Input: 100 ohm RTD, resolution 0.01C Serial Communication: RS232 or RS485 (printing, data
recording and communications with a computer) Flow Inputs: Pulse, single rotor, dual rotor, single rotor with dual
pickups or quadrature Control Inputs: Menu-selectable for Start, Stop, Reset, Lock,
Inhibit, Alarm Acknowledge, Print or Not Used Relay Outputs: Menu-assignable Low Rate Alarm, Hi Rate
Alarm, Prewarn Alarm, Preset Alarm, or General Purpose Warning
PANEL MOUNT FLOW COMPUTERS
FLOW COMPUTERS, METER MOUNTED & REMOTE
Series EC80 ExactComp, Flowmeter Interface
Description:
COX Series EC80 ExactComp Flowmeter Interface provides total ow compensation to enhance owmeter accuracy, while
extending the linear ow range. The Series EC80 tracks all variables to compensate for viscous and inertial effects due to uidtemperature and pressure variations. Enhanced DSP technology allows exceptional signal characterization and fast response
outputting dynamic data in engineering units. Meeting the demanding requirements of the aerospace, automotive and test &measurement industries, the Series EC80 provides signicant improvements in owmeter accuracy under extreme
temperature conditions. It can be mounted directly on the owmeter or in a remote box.
Remote-mounted
Flow Computer
Meter-mounted
Flow Computer
-
7/14/2019 Cfm Flowmeter Catalog
22/28
22
FLOW COMPUTERS, METER MOUNTED & REMOTE
FLOW STRAIGHTENERS
INSTALLATION
AN End-Fittings
Flange End-Fittings
NPT End-Fittings
Tri-Clover End-Fittings
COX Turbine Flowmeters can be installed in any position, without
affecting performance. To reduce ow turbulence, COX recommendsusing ow straighteners, which have 10 diameters in length
upstream and 5 diameters in length downstream, with vanes.
Where impractical due to space limitations, careful attention to
the location of valves, bends, etc., is suggested. A 10-micron
lter on the small meters is recommended to prevent bearing
contamination.
Electrical installation requires a 3-conductor shielded cable tothe readout device.
Specications:Performance
Linearized Frequency: 0.1% of reading Linearized Analog Output: 0.1% of full scale RTI
(>100K load impedance) Process Latency: 100 microseconds
Input Power
24 VDC nominal, 3W max. 9-32 VDC (digital output only)
12-32 VDC (analog output voltage) 15-32 VDC (analog output, 4-20 mA)
Temperature Environment
Operating: -40F to 185F (-40C to 85C) Storage: -67F to 257 F (-55C to 125C)
Humidity: 0-80% RH non-condensingTemperature Input (2-, 3- or 4-wire)
RTD 100 Ohm Platinum, 0.00385 Alpha
IEC751 Class B Standard Usable Range: -65F to 365F (-54C to 185C)
Voltage: 0-10 VDC or 0-5 VDCAnalog Outputs 2 Independent Channels
Ch 1, 4-20 mA or 0-10 VDC Ch 2, 0-10 VDC only
16-Bit Resolution, 4-20 mA, 0-10 Volts 15-Bit Resolution, 0-5 Volts Load Impedance,
-
7/14/2019 Cfm Flowmeter Catalog
23/28
23
The Flow Gator is a fully contained data acquisition system, which includes signal conditioning. Use by the U.S. Armed Forces
to calibrate owmeters onboard ships and in aircraft test facilities gives credence to its capability and ease of use. Meets SAE
ARP4990 Calculation Standards.
PROVEN PERFORMANCE FOR OVER 50 YEARS
FLOW TRANSFER STANDARDS
System Uncertainty 0.15% of reading(Depending on Master Meter type and calibration)
Frequency Meter Inputs 0.001% of readingAccurate to 25 nanoseconds
Analog Meter Inputs 0.02% of readingAccurate to 16-bit resolution
Display 4 Lines x 20 Characters
Linearity (with linearizer) 0.01% of reading
Operating Temperature -40F to 140F (-40C to 60C)
Engineering Units GPM, LPM, PPM, PPH
Temperature Units F,C, R, K
PERFORMANCE SPECIFICATIONSADVANTAGES
NIST traceable
SAE ARP 4990 conformance Works with all types of master meters
Performs automatic viscosity and density correction
Handheld data acquisition system, includingall sensor interface ampliers
No need for a PC in the eld
Stores up to 5 master meters and 5 uids
User-friendly, easily programmable
Includes optional manifold control capability
Flow GatorMaster Meter System
The Flow Gator is capable of controlling anextended ow range manifold and willautomatically select the proper mastermeter to compare with the UUT.
COX Flow Measurement offers a field
solution for calibrating all types of owmeters.Instead of removing equipment from service
for recalibration, the innovative Flow Gator
Flow Transfer Standard (FTS) allows users
to bring the calibrator to the owmeter.This affordable documenting eld owcalibrator is intended for in-line calibration
and validation of meters using the actualprocess liquid.
The Flow Gator FTS is compatible with any
owmeter with an electronic output orvisual indicator, and is capable of measuring
and correcting the inuences of linepressure and temperature effects on ow.The calibrator reads signals from a master
owmeter, a unit under test (UUT) and uid
temperature. With this data, it calculates
and compares the precise ow rate fromthe master meter and UUT.
Rugged, lightweight and compact, the Flow
Gator incorporates hand-held electronics,thus eliminating the need to carry a laptopcomputer into the eld. The master meter
can be any meter of choicepreferablyan Exact Series Dual Rotor Turbine
Flowmeter, which providesexceptional repeatability of
0.02%, enabling total systemuncertainty of 0.25% of reading.
Flow GatorHandheld DAQ
System
-
7/14/2019 Cfm Flowmeter Catalog
24/28
24
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
The PDCL Series Primary Standard Calibrators are used daily in our prestigious NVLAP calibration lab. As a user, we continually
implement time-saving features such as uid lling, mixing and viscosity temperature control, while improving on operator
efciency and ensuring minimal maintenance.
PERFORMANCE SPECIFICATIONS
Flow Dynamics, part of the COX Flow Measurement family,is known for the industrys most advanced primary standard
positive displacement ow calibrators. These liquid owcalibrators are the equipment-of-choice across a wide range
of industries, and are in use throughout the world in the mostprestigious government primary standard laboratories.
The Flow Dynamics Positive Displacement Calibrator, Liquid(PDCL) 10, 60 and 400 Series calibrators perform NIST traceable
calibrations ranging from 0.01 GPM (0.04 LPM) to 400 GPM(1514 LPM) with an uncertainty of 0.05% and a repeatability of
0.01% of reading. They are compatible with most common
owmeters providing a visual, pulse, or analog output.
The PDCL Series is a precision volumetric device displacing anexact known volume of uid passing through the owmeter
under test, while compensating for temperature effects onviscosity. The PDCLs low uid usage supports the need to
reduce hazardous uids, while keeping uid costs to aminimum. Blending uids is made easy with an automaticcycling feature for mixing uid while in the machine. In addition,
the calibrators piping loop is designed to assist draining uidsout of the system and facilitate ushing to clean residual uid
out of the piping.
Flo-Cal User Interface: The PDCL Series employs Flo-Calsoftware, which is seamlessly compatible with Windows
operating systems, to graph and produce calibration datareports. The software graphics display visual aids calibration
data/plots, and the data reports are user-congurable.Calibration les are automatically stored for owmeterperformance history and can be recalled for plot comparison
to the current calibration.
Field Service: In addition to manufacturing new primarystandard calibration systems, COX Flow Measurement offers
eld certication and service worldwide. All calibrators are
100% documented to ensure service support for the life ofthe calibrator.
FLOW DYNAMICS PRIMARY STANDARDPOSITIVE DISPLACEMENT FLOW CALIBRATORS
PROVEN PERFORMANCE FOR OVER 50 YEARS
-
7/14/2019 Cfm Flowmeter Catalog
25/28
Proven Performance for Over 50 Years
25
PRIMARY STANDARD POSITIVE DISPLACEMENT FLOW CALIBRATORS
Measurement Range 0.01 to 400 GPM
Uncertainty 0.05% of reading
Repeatability 0.01% of reading
Temperature Reading 0.02F of reading
Viscosity Range 0.5 to 1000 CentistokesAmbient Operating Temperature 60F to 90F
(15.5C to 32.2C)
Fluid Operating Temperature 40F to 140F(4.4C to 60C)
Operating Pressure Up to 120 psig
PERFORMANCE SPECIFICATIONSADVANTAGES
High precision measurement capability
Heater/Chiller to control uid viscosity
Calibrations traceable to national standards
Same calibrator design as used by NIST
User-friendly software allows easy operation
Provides automatic data acquisition
Low uid usage reduces costs
User features to reduce calibration time
Operator enhancements incorporated in the PDCL Series calibrators
3 Valve Manifold Flow Adjustments
Heater & Chiller Fluid Viscosity Control
Auto Pneumatic Air Bleed ValvesServo Driven Telescope Tube
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
Integral Data Acquisition System
-
7/14/2019 Cfm Flowmeter Catalog
26/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
26
OEM SEMI-AUTOMATIC CALIBRATORS
CALIBRATOR CHECK STANDARDS
Semi-automatic calibrators are available for OEMs with high-volume calibration requirements.These systems incorporate owmeter quick-load xturing.
COX Flow Measurement Check
Standards are used by NIST in
their intra-laboratory test todetermine bias between
primary standard calibration
labs for the armed forces and
major labs.
Check Standards are used to verify the repeatability of a primary standard
calibrator. They ensure that nothing has changed in the ability of the calibratorto repeat its former calibration data. Calibration data curves should lay over eachother within
-
7/14/2019 Cfm Flowmeter Catalog
27/28
Proven Performance for Over 50 Years
COX Flow Measurement application engineers will help you congure the proper system for your
application. They can be reached at 480-922-7446 or by email at [email protected].
Application technical tips are also available at www.coxow.com
27
PROVEN PERFORMANCE FOR OVER 50 YEARS
MANUFACTURING CELLS
COX Flow Measurement recognizes the need for 100%
product performance when manufacturing ow measurement
instruments for OEM applications. Our world-class owmeterproduction line is compliant with the ISO/TS-16949
automotive industry standard. We have implemented acomprehensive quality documentation system addressing
every process required to economically produce the highestquality ow measurement products.
COX Flow Measurements OEM manufacturing cell capabilityprovides material and assembly traceability on each
owmeter delivered, encompassing total quality from raw
materials to nished products. The end-result drives product
condence, eliminating liability and potential costly
replacements, while minimizing product cost.
ADVANTAGES
Compliant with ISO/TS16949
APQP includes: Production Part Approval Process (PPAP)
Process Failure Modes Effects Analysis (PFMEA) Design Failure Mode Effects Analysis (DFMEA) Six Sigma-level quality standards
COX Flow Measurement invites you to evaluate the cost of manufacturing your owmeter in one of our world-class cells. High
volume calibrations are also provided for owmeter manufacturers with timely deliveries you can count on.
-
7/14/2019 Cfm Flowmeter Catalog
28/28
Proven Performance for Over 50 Years
(480) 922-7446
www.coxow.com
COX Flow Measurement, based in Scottsdale, Arizona USA, offersone of the industrys largest selections of ow measurementproducts and services. Customers are also encouraged to takeadvantage of our world-class applications engineering assistance.We have the expertise to help you solve the most difcult liquid andgas ow metering applications!
COX precision owmeters are recognized for their uncompromisedaccuracy and reliability. All of our products are manufactured incompliance with AS9100, ISO 9001 and other strict industry qualitystandards.
Most COX owmeters are delivered in 4 weeks or less, and manymodels are in stock. We also offer expedited deliveries, dependingon the complexity of the calibration.
If you demand superior owmeter accuracy and reliability, choose COX!
FM78587AS9100 and ISO 9001
Manufactured under an ISO 9001 and AS9100 registered quality management system.
15555 North 79th PlaceScottsdale, AZ 85260Tel: (480) 922-7446Fax: (480) 948-3610