Duraisamy P
Sr. Development Engineer
CFD analysis of ceiling fan
by
Lucas TVS Limited
22nd July 2016
2
Company profile
Established 1962, JV - Lucas UK and TVS
Wholly owned since 2001
7 plants in India
Main plant in Chennai - 2600 employees
Complete Product development capability 75% of revenue from products
developed In-house
TS16949 and OHSAS 18001 certified company
Deming grand prize in 2012 for excellence in applying the principles of
TQM
3
Products
4
CFD analysis of ceiling fan
Objective of case study
To perform flow simulation of ceiling fan.
Analyse the fluid flow and predicted results.
Establish correlation with experimental data.
5
Geometry Nomenclature and Spec
Top canopy
Downrod
Blade
Blade flange
Specifications
Fan sweep 1200 mm
No of blade 3
Blade thickness 1.2 mm
Fan speed 350 RPM
Range of speed 280-350 RPM
Rotation CCW from floor
Evaluate flow rate as per IS 374 -1979 specification.
Determine mechanical input power
6
IS 374-1979 spec - test chamber
7
Virtual flow chamber
4.2
5 m
8
Virtual chamber surfaces
Floor
Bottom opening
Outer wall
Roof
Top opening
Test chamber wall
9
Diaphragm - Top opening and Rot domain
Enlarged View
Top opening recommanded diameter is 1.1 to 1.2 times of fan sweep diameter.
Fan - Rotating domain
10
Surface and Volume mesh
Mesh - Cut section view
Surface Mesh
Boundary layer mesh created over blade surfaces. Conical mesh created to capture flow under fan region.
Surface mesh created in HM.Surface mesh can constrcut volume.
11
Input details and Boundary conditions
Material properties: Input speed:
Density of air 1.2 kg/m3
Viscosity of air 1.8 e-5 Ns/m2
Boundary Condition:
• Wall BC to all the outer walls.
• No BC to rot domain surfaces.
• Pressure point is created in domain
to initiate simulation.
12
Velocity measurement points
Test chamber wall
Probe points at four semi diagonalsbegins at 40 mm from centre and 80 mm incremental in all diagonals.
The measurement plane located 1.5 m below plane of fan blades.
Mesurement points are shown below which are used to read value of velocity.
13
Solution convergence - AcuProbe
14
Stream lines
Air entering into top opening and fan moves air with higher velocity.
Air comes out through bottom opening from chamber and circulated.
15
Velocity contour
X Z plane - velocity contour
Z axis component velocity contour shown below
16
Velocity contour cont..
X Y plane - velocity contour
0.01 m 0.5 m
1 m 1.5 m
17
CFD results
Steady state analysis performed.Velocity evaluated at discrete points of four semi diagonals.Geometry position - A blade oriented to Y axis.
0 Deg
18
CFD results - Three different initial positions
Accumulated air flow rate : 242 CMMTorque required to develop flow : 0.75 Nm @ 350 rpm
0 Deg30 Deg
60 Deg
19
Test results
Velocity profile along four semi - diagonals are shown below.
Accumulated air flow rate : 231 CMMTorque : 0.74 Nm @ 350 rpm
20
Comparision
S No Parameters Test results CFD results Remarks
1Flow domain
size
IS 374 - 1979
followed
IS 374 - 1979
followed
Thickness of chamber neglected
2Speed
RPM350 350
Input for simulation
3Flow rate
CMM231 242 5% variation
4 Torque
Nm0.74 0.75 2% variation
5Power
W27 W 27.5 2% variation
21
AcuSolve could predict the flow parameters for given input speed of ceiling fan
by
1. Flow rate >95 % accuracy.
2. Torque >95% accuracy
Conclusion
22
Benefits summary
Flow simulation method has been established to evaluate airflow rate and mechanical input power of fan as per IS 374 - 1979 specification.
This methodology proposed to optimize fan blade design in order to improve efficiency.
23