This guide should help you choose the right HTI centrifuge for your specific needs.

Speed (RPM) vs. g-Force (RCF):The most important factor when choosing a centrifuge is the g-Force, or RCF, not the speed. The RCF determines the ability ofa centrifuge to separate the specimen. Most specimens must bespun within a specific RCF range in order to properly prep thesample for testing and analysis. The guide below will help youselect a model based on RCF, RPM, # of tubes, specimens andother attributes.CLIA, Calibration and speed checking:Your lab or practice may be subject to CLIA regulations if whatyou do is considered to be "moderately complex", or "highlycomplex". CLIA, (Clinical Laboratory Improvement Amendment of 1988); may dictate that your centrifuges need to be"Calibrated" every 6 months. CLIA inspectors may visit yourfacility to make sure you are maintaining your equipment andfollowing protocols; and that your equipment is capable ofperforming the protocols properly, etc. Calibration involves using a tachometer to check the speed of your centrifuge for accuracy. CLIA inspectors will "pass" a centrifuge that operates within plus or minus 100 RPM of the actual setting. If for example, your centrifuge is set to spin at 3,400 RPM; CLIA will pass it if it is anywhere between 3,300 and 3,500 RPM; as long as your protocol calls for spinning in that range as well. To check your centrifuge you can purchase a tachometer, item # C800-75.

Urine Sample Centrifugation:A note of caution if you spin Urine specimens: If you have a fixedspeed centrifuge, chances are very good it is set the RCF andspeed for spinning blood samples only. Urine specimens must bespun at a greatly reduced RCF in order to properly prep thesample. If your facility is subject to CLIA and you spin urinesamples in a blood centrifuge, the CLIA inspector may not allowthe centrifuge to pass inspection. You will be asked to either stopspinning urine samples, or acquire a centrifuge capable ofspinning at the correct RCF for separating urine samples.

Item No. DescriptionC800-75 Photo-Tachometer

Digital Photo-Tachometer• RPMs instantly display on large

LCD screen• Standard adhesive reflective

tape included• Highly accurate scientific tool,

includes case

Centrifuge Selection Guide

Number Tube Specimens DNA Maximum Maximum Model SKU of Tubes Capacity Blood Fecal Urine Microhematocrit Protein Speed Rotor RPM RCF (g)

FX C806 6 2-15 ml Yes No No With Adapters No Fixed Fixed 3400 1320

FX C808 8 2-15 ml Yes No No With Adapters No Fixed Fixed 3400 1320

LX C856 6 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 300-4,000 Up to 1,828

LX C858 8 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 300-4,000 Up to 1,828

PX C826 6 2-15 ml Yes No No With Adapters No Fixed Fixed 3,500 1,640

PX C828 8 2-15 ml Yes No No With Adapters No Fixed Fixed 3,500 1,640

HX C822 6 2-15 ml Yes No No With Adapters No Fixed Horizontal 3,400 1,680

DX C8724 24 2-15 ml Yes Yes Yes With Adapters No Variable Fixed 500-4,000 2,508

DX C8706 6 2-15 ml Yes Yes Yes With Adapters No Variable Horizontal 2,508

DX C8760 4 60 ml 60 mL No No No No Variable Fixed 2,508

DX C8704 4 2-50 ml Yes Yes Yes With Adapters No Variable Horizontal 2,508

CMH CMH30 24 Capillary MH No No Yes No Fixed Horizontal 12,000 14,075

BX C881 6 2-12 ml Yes Yes Yes With Adapters No Variable Fixed 5,000 2,570

BX C882 24 Capillary MH No No Yes No Variable Horizontal 11,000 13,250

BX C883 24 0.5-3 ml Yes No No No Yes Variable Fixed 13,000 15,495

C806 C822 C8724 CMH30 C881M

How to calculate RCF:RCF = Relative Centrifugal Force (also known as “G-Force”)

Centrifuge RCF Calculation: RCF = 1.12 x R(mm) xKrpm x Krpm

where R: Centrifuge rotor radius (mm)and Krpm: Centrifuge speed in thousands

Example: If rotor radius is 102mm, speed is 3.4Krpm(3400rpm), then RCF = 1.12 x 102 x 3.4 x 3.4 = 1320g

HTI PowerSpin™ Centrifuge Selection Guide

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

500-4,000

500-4,000

500-4,000

Page 3: Centrifuges - technoserve.info

PowerSpin™ FX LX HX PXModel C806 / C808 C856 / C858 C822 C826 / C828Rotor radius 102 mm 102 mm 130 mm 102 mm

RPM RCF RPM RCF RPM RCF RPM RCFFecal Speed 1400 224Fecal Time 10 minutesUrine Speed 2000 456Urine Time 5 minutesBlood Speed 3400 1320 3100/4000 1097/1828 3400 1680 3500 1640Blood Time 10-15 minutes 10 minutes 10 minutes 10 minutes

N/A

N/A

PowerSpin™ Centrifuges, FX / LX

Item No. DescriptionC806 FX, 6 Place Fixed Speed Centrifuge, 3400 rpmC806H FX, C806 with Tube HoldsterC808 FX, 8 Place Fixed Speed Centrifuge, 3400 rpmC808H FX, C808 with Tube HoldsterC856 LX, 6 Place Variable Speed Centrifuge, 300 - 4000 rpmC856E LX, 6 Place, same as above, 220VC856H LX, C856 with Tube HoldsterC856H-E LX, C856E with Tube Holdster, 220VC858 LX, 8 Place Variable Speed Centrifuge, 300 - 4000 rpmC858E LX, 8 Place, same as above, 220VC858H LX, C858 with Tube HoldsterC858H-E LX, C858E with Tube Holdster, 220VC800-01 8 Place Rotor for PowerSpin CentrifugesC800-02 Tube Shield, Pkg. of 2C800-03 Short Tube Adapters, for 4-7 ml tubes, Pk/10C800-04 Small Tube adapters, for 2 ml tubes, Pk/2C800-05 Greiner Tube Lift Adapters, Pk/12C800-18 Tube Holdster, 18 Place

Actual Size: 10.2” x 11.8“ x 8”Shipping Dimension: 13.4” x 14.8” x 10.6“Net Weight: 15 lbsShipping Weight: 18 lbs

HTI® PowerSpin™ Series centrifuges are compact, economical and quiet. We offer both fixed (FX) and variable (LX) speed models with fixed angle rotors, for 6 or 8 tubes to spin 7.5– 15 ml tubes. By using adapters, you can also spin tubesranging from 2 – 7 ml. An optional Tube Holdster™ allows you tohave up to 18 tubes or adapters at your fingertips, side-mountedon the centrifuge. PowerSpins are pre-drilled/tapped to acceptoptional Tube Holdsters.

Specifications:• Standard 6 or 8 place rotor for 2 to 15 ml tubes• Adapters for 2 ml or 4-7 ml tubes (part # C800-04 & C800-03)• 0-30 minute timer with bell tone signal• Quiet at full speed, only 58 decibels• Latching lid with safety switch triggered to shut-off power to the

motor when the lid is opened• Stainless Steel rotor chamber is easily accessible for cleaning

and disinfection• Maintenance-free brushless motors• Suction cup rubber feet for stability while reducing vibration• Lid window for strobe tachometer RPM check• One Year Limited Warranty

PowerSpin™ Centrifuges, Models FX and LX

LX Color Coded QuickSpeed setting reference:

Brown FecalYellow UrineRed Blood

C856 Model LX Centrifuge

RPM = Revolutions Per MinuteRCF = Relative Centrifugal Force (also known as “G-Force”)

C806 Model FX Centrifuge

C800-04 C800-05 C800-03 Tube Shield

Shown with optionalTube Holdster™

Tube Adapters

N/A N/A

N/A N/A

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

Page 4: Centrifuges - technoserve.info

PowerSpin™ Centrifuges

Specifications:• Horizontal Six place rotor for 2 to 10 ml tubes• Quiet at full speed, only 58 decibels• Stainless Steel chamber for easy cleaning and disinfection• HX models run at fixed speed 3400 RPM• 0-99 minute digital timer• Suction cup rubber feet add stability while reducing vibration• Lid window for strobe tachometer RPM check• One Year Limited Warranty

The horizontal spin fixed speed PowerSpin™ HX centrifuge spinsat 3400 RPM. The horizontal rotor insures a clean, completeseparation of cellular components. Using a horizontal rotor forspinning Serum Separator Tubes (SSTs) creates a tight uniformhorizontal seal, reducing the risk of red cell leakage.The C822 features a Zero RPM safety lock, so the lid can not be opened while the rotor is in motion. A digital timer and LCDdisplay provide user with the precise control of the spin cycle.Powerful brushless motor is maintenance free for years ofdependable use. Stainless steel guard bowl is easy to clean andmaintain.

PowerSpin™ Centrifuge, HX Horizontal Spin

C822 Model HX HorizontalCentrifuge

Actual Size: 14.4” x 11.6“ x 8.9”Shipping Dim.: 16.5” x 13” x 10“Net Weight: 22 lbsShipping Weight: 25 lbs

Specifications:• Designed for the professionals on the go• Plugs into a car 12V power outlet• 3500 RPM fixed speed for blood• 30 minute timer• Convenient stainless steel carrying handle• Lid mounted "fish-eye" level to level before spinning• Optional AC power adapter available• One Year Limited Warranty

The PortaSpin PX allows you to take your practice on the road.Whether you are a mobile vet, visiting nurse or doctor, we havea PortaSpin that will meet your needs. Available with 6 or 8place rotors and adapters to fit tubes ranging from 2 – 15 ml.Standard with 12 Volt car lighter adapter, a 110V electrical outletadapter is optional for use back at the lab. When using this unit you will most likely not be in your lab settingso you will not have you standard bench-top tube rack. Westrongly recommend purchasing the optional Tube Holdster,attaches easily to the side of the centrifuge and will hold up to 18tubes or adapters.

PowerSpin™ PortaSpin™Centrifuge, PX Mobile

C826H Model PX PortaSpin™Item No. DescriptionC826 PX, PortaSpin 6 Place Mobile CentrifugeC826H PX, PortaSpin 6 Place Mobile Centrifuge

with Tube HoldsterC828 PX, PortaSpin 8 Place Mobile CentrifugeC828H PX, PortaSpin 8 Place Mobile Centrifuge

with Tube HoldsterC826-06 PX, PortaSpin 12V DC Car AdapterC826-12 PX, PortaSpin 110V AC AdapterC826-12E PX, PortaSpin 220V AC AdapterC800-03 Short Tube Adapters, for 4-7 ml tubes, Pk/10C800-04 Small Tube adapters, for 2 ml tubes, Pk/2C800-05 Greiner Tube Lift Adapters, Pk/12C800-10 Fuse for PowerSpin CentrifugesC800-18 Tube Holdster, 18 Place

PortaSpin features a level built into the lid tomake sure you are level before and duringyour run. A sturdy stainless steel handlemakes carrying the centrifuge easy.

Actual Size: 10.2” x 11.8“ x 8”Shipping Dimension: 13.4” x 14.8” x 10.6“Net Weight: 15 lbsShipping Weight: 18 lbs

C800-34 Microhematocrit Adapters

Item No. DescriptionC822 HX, 6 Place Horizontal Spin CentrifugeC822-01 6 Place Swing Out RotorC822-02 Tube Shield, Pkg. of 2C800-03 Short Tube Adapters, for 4-7 ml tubes, Pk/10C800-04 Small Tube adapters, for 2 ml tubes, Pk/2C800-34 Microhematocrit Adapters, 4 tubes each, Pk/2

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

Page 5: Centrifuges - technoserve.info

• Zero RPM Safety Latching System preventslid from being opened while rotor is spinning

• Quiet running, only 50 decibels at 3400 RPM• 99 minute digital timer , 1 sec increment• 500-4000 RPM, 100 RPM increment

HTI® is proud to present the PowerSpin™ DX Centrifuge

With 4 rotor options this centrifuge is a great answer for every day laboratory tasks. - 24 place fixed rotor for 2-15ml tubes (#C8724 )- 6 place horizontal rotor for 2-15ml tubes ( #C8706 )- 4 place horizontal rotor for up to 50ml tubes (#C8704 )- 4 place fixed rotor for 60ml syringes (#C8760 )

The PowerSpin™ DX has variable speed 500 – 4000 RPM,to ensure a clean and complete separation. Quiet and

dependable, with a maintenance free motor, it can be usedto process blood, urine, semen and other specimens.

The all digital front panel makes it easy to select speed and run time. Oversized LCD display shows status, time, speed (RPM) and RCF (g). Precise speed control enables you to comply with CLIA recommendations for specific specimens.

• Remembers last setting for quick repeat runs• Adjustable Acceleration and Deceleration• Stainless steel rotor chamber for easy cleaning• Suction cup rubber feet eliminate vibration• Available in 110V and 220V - Contact HTI for details

Professional Digital Non-Contact Photo-Tachometer

• Highly accurate, scientific tool• Easy to operate• Standard adhesive reflective tape (included)• Aim and measure--RPMs instantly display on large LCD screen.• Includes custom protective cushioned storage case• Order pn# C800-75

Model #C8724

PowerSpin™ Centrifuges, DX

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

Page 6: Centrifuges - technoserve.info

UNICO Model Item Speed Max. RCF Rotor Tube Size Tube Holdster 24 place

PowerSpin™ DX C8724 500 – 4000 RPM 2508 24 place fixed 2-15ml Optional

PowerSpin™ DX C8724H 500 – 4000 RPM 2508 24 place fixed 2-15ml Included

PowerSpin™ DX C8706 500 – 4000 RPM 2508 6 place horizontal 2-15ml Optional

PowerSpin™ DX C8706H 500 – 4000 RPM 2508 6 place horizontal 2-15ml Included

PowerSpin™ DX C8704 500 – 4000 RPM 2508 4 place horizontal 50 ml Optional

PowerSpin™ DX C8704H 500 – 4000 RPM 2508 4 place horizontal 50 ml Included

PowerSpin™ DX C8760 500 – 4000 RPM 2508 4 place fixed 60 ml N/A

Model C8724 • 24 place fixed angle rotor ( pn#C8600-03 — rotor only)

• Designed to accept 10ml blood tubes and up to 15ml urine tubes

• 2ml tubes with small tube adaptor (pn# C800-04 — set of 2)

• 5ml tubes with short tube adaptor (pn# C800-03 — set of 10)

Model C8706 • 6 place horizontal rotor ( pn#C8600-01 — rotor only)

• Specifically designed to keep tubes vertical at rest

• Designed to accept 10ml blood tubes and up to 15ml urine tubes

• 2ml tubes with small tube adaptor (pn# C800-04 — set of 2)

• 5ml tubes with short tube adaptor (pn# C800-03 — set of 10)

Model C8704

• 4 place horizontal rotor ( pn#C8600-02 — rotor only)

• Designed to accept 50ml tubes

• With adaptors can accept most of the tubes used in laboratory

• 6 to 15ml tubes with adaptor (pn# C8604-02 — set of 2)

• 3 to 5ml tubes with adaptor (pn# C8604-03 — set of 2)

• 0.5 to 2ml tubes with adaptor (pn# C8604-04 — set of 2)

Model C8760 • 4 place fixed angle rotor ( pn#C8600-05 — rotor only)• Designed to accept 60ml Syringes

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

Page 7: Centrifuges - technoserve.info

PowerSpin™ Centrifuges, BX

The BX is a versatile, state of the art variable-speed centrifugeseries with three rotor options. Options are: • Blood/Urine Tube, 2-12 ml Rotor: Max Speed = 5,000 RPM

• Microhematocrit/Capillary Tube Rotor: Max Speed = 11,000 RPM

• Microcentrifuge Tube, 0.5-3 ml Rotor: Max Speed = 13,000 RPM

Your BX can be a dedicated centrifuge with any one of the rotors,or a versatile addition to your lab with up to threeinterchangeable rotors with speeds from 1,000 – 13,000 RPM.BX Centrifuges have advanced safety features such as a ZeroRPM lid latch control system (which makes sure the lid can not beopened if the rotor is spinning), a stainless steel rotor chamber,Auto-unbalance detection and shut-down (will shut-down the motorif an off-balance condition is detected). With threeinterchangeable rotors, the centrifuge features ARD (AutomaticRotor Detection), the unit can automatically tell which of the threerotors are loaded. This is an important safety feature as each ofthe three rotors has a different maximum speed.The Microhematocrit rotor features a Tube Reader built-into therotor lid. This makers reading crit values quick and easy afteryour run, without having to remove the tubes and place them in areader, or on a reader-card, etc. The standard Blood & Urinetube rotor fits 7.5 – 12 ml tubes and will not accept 15 ml tubes.With adapters shown below, you can spin 0.5 – 3 ml tubes(C800-04), or 3.5 – 6.5 ml tubes (C800-03).

PowerSpin™ Centrifuge, BX

Specifications:• Variable speed up to 13000 RPM (up to 5000 RPM on C881)• Zero RPM Safety Lock and Rotor Unbalance Sensor• Automatic Rotor recognition• Digital Timer 0-99 minutes• Maintenance free brushless motor• Exterior is chemical resistant and easy to clean and disinfect• Lid window for strobe tachometer RPM check• Standard 115V/60Hz; (220V/50Hz option available)• One Year Limited Warranty

Item No. DescriptionC881M BX, 6 Place Fixed Angle Metal Rotor CentrifugeC881ME BX, 6 Place, Fixed Angle Metal Rotor Centrifuge, 220VC882 BX, 24 Place Hematocrit CentrifugeC882E BX, 24 Place Hematocrit, same as above, 220VC883 BX, 24 Place Micro-Tube CentrifugeC883E BX, 24 Place Micro-Tube, same as above, 220VC884 BX, 6 Place Tube rotor & 24 Place MicrohematocritC884E BX, 6 Place Tube rotor & 24 Place Microhematocrit, 220VC885 BX, All three available rotors, 110VC885E BX, All three available rotors, 220VC886 BX, 24 Place Microhematocrit & 24 Place MicrocentrifugeC886E BX, 24 Place Microhematocrit & 24 Place Microcentrifuge, 220VC887 BX, 6 Place Tube rotor & 24 Place MicrocentrifugeC887E BX, 6 Place Tube rotor & 24 Place Microcentrifuge, 220VC881-03 Short Tube Adapters, for 4-7 ml tubes, Pk/10C881-04 Small Tube adapters, for 2 ml tubes, Pk/2C800-34 Adapters for four Microhematocrit tubes, Pk/2C8600-34 Adapters for four Microhematocrit tubes, Pk/2C800-512 12 ml Conical Urine Tube, 16 x 100 mm, Pk/12C800-550 12 ml Conical Urine Tube, 16 x 100 mm, Pk/50C800-500 12 ml Conical Urine Tube, 16 x 100 mm, Pk/500

Digital LCD display and push buttoncontrol panel are designed to give theuser complete control throughout the spin cycle.

• The “Open” button is disengaged whilethe rotor is in motion

• LCD mode button will adjust displayeddata according to your preferences

PowerSpin™ BX BX BXModel C881 C882 C883Rotor radius 92 mm 86 mm 82 mm

RPM RCF RPM RCF RPM RCFFecal Speed 1600 263Fecal Time 10 minutesUrine Speed 2000 411 2300 485Urine Time 5 minutes 5 minutesBlood Speed 5000 2570 13,000 16,250 13,000 15,495Blood Time 4 minutes 5 minutes 5 minutes

N/A

C881

N/A

N/A

RPM = Revolutions Per MinuteRCF = Relative Centrifugal Force (also known as “G-Force”)

High Technology, Inc. www.htidiagnostics.com

(508) 660-2221 MA USA

Page 8: Centrifuges - technoserve.info

PowerSpin™ Centrifuges, BX

24 place rotor for capillaryMicrohematocrit tubes. HematocritReader incorporated into the cover

24 place rotor for 0.5 to 3ml Micro tubes

6 place Blood/Urine Tube Rotor(accepts maximum 12 ml urine tubes)

Item No. DescriptionCMH30 Microhematocrit Centrifuge, 24 Place, 110VCMH30E Microhematocrit Centrifuge, 24 Place, 220VCMH30-Reader Microhematocrit Tube Reader

CMH30 Centrifuge

Select from three rotor options for yourBX centrifuge. For your convenience, wedesigned the C880-10 BX Rotor Rack tostore all three rotors, the rotor changingtool and all your accessories. This rackcan sit bench-top next to the BX, or canbe wall-mounted, whichever works bestfor your lab. Also includes 18-place TubeHoldster™ for any size tube from 2-15ml.

BX Rotors and Acrylic Rotor Rack

Item No. DescriptionC880-01M Metal, 6-Place Blood/Urine

Tube RotorC880-02 24-Place Microhematocrit RotorC880-03 24-Place Microcentrifuge RotorC880-10 BX Rotor Rack with

Tube Holdster™

BX Versatility: New Microhematocrit Tube Adapters: We have developed several microhematocrit tubeadapters that can be used with the Blood & Urine Tube Rotor, making a single rotor much moreversatile and eliminating the need to purchase an additional rotor, or change rotors. Both New C800-34 and C8600-34 Adapters come in a Pkg/2 adapters, each and each adapter holds up to 4 MHtubes. The Blood & Urine rotor runs at a max of 5,000 RPM, much slower than traditionalmicrohematocrit rotors with a 5 min. run. With our adapters, at 5,000 RPM, you can achieve acomplete microhematocrit separation in an 8 min. run. The BX’s large digital display continuously shows three parameters in real-time: Speed (RPM), g-Force(RCF) and Time – how much time is left in the run. A unique feature allows the user to select which ofthese three parameters to display in an extra large font, for quick and easy viewing. BX’s feature maintenance-free brushless motors and a lid window for tachometer calibration checks.An intuitive button panel is quick and easy to use.

PowerSpin™ Centrifuge, BX

Model CMH30 is made of formed metal and has a baked paintapplication that is acid and reagent resistant. A safety switch builtinto the handle assembly disconnects the power to the motorwhenever the latch is lifted. The brushed motor is mounted onrubber mounts to provide quiet running and dampen vibration.

CMH30 Microhematocrit Centrifuge

Specifications: • Twenty-four (24) place rotor with replaceable rubber ring and screw

down metal lid• Includes Microhematocrit Tube Reader• Nominal speed is 12,000 RPM• Dependable mechanical 5-minute timer with bell signal at end of run• All metal housing for years of dependable use• Safety switch in latch shuts off motor when lid is lifted• Electric motor braking• Indicator light tells when unit is in use• Standard 115V/60Hz AC• One Year Limited Warranty

Actual Size: 11.6” x 10.3“ x 9.3”Shipping Dim.: 12.7” x 12.7” x 12.2“Net Weight: 17.4 lbsShipping Weight: 19.4 lbs

Microhematocrit Tube Readerincluded with CMH30

The BX Acrylic Rotor Rack organizes your rotors, rotorchanging tool, and accessories all in one compact unit.

High Technology, Inc. www.htidiagnostics.com