cellecta sound proofing solutions refurbishment brochure may 2012

Upload: gorgan-vlad

Post on 30-Oct-2015

59 views

Category:

Documents


0 download

TRANSCRIPT

  • Y (P2)

    CI/SfB

    (43)

    PART

    2010

    L

    solu

    tions

    PART

    2003

    E

    solu

    tions

    PART

    2010

    L

    solu

    tions

    PART E

    Solu

    tions

    CellectaR

    I N N O V A T I O N I N I N S U L A T I O N

    Refurbishment & Conversion Projects

    Sound Proofing Solutions

    Thin floor and wall treatments

    Domestic acoustic insulation

    Quick and easy to install products

    Proven constructions

    YELO

    fon

    fon

    FIBREfonfon

    DECKfonfon

    Scree oarddB HiGYP

    Sound Proofing Solutions

  • oCellecta is the UKs N 1 manufacturer of high performance acoustic treatments

    and specialist insulation products. For over 20 years, our extensive range of products

    has been supplied to all sectors of the construction industry including: house builders,

    building contractors, ground workers, screeders, roofers and dryliners.

    CellectaR

    I N N O V A T I O N I N I N S U L A T I O N

    DECKfon, FIBREfon, YELOfon, ScreedBoard and HiGYP are registered trademarks of Cellecta Limited.

    YELOfonfon

    FIBREfonfon

    DECKfonfon

    Scree oarddB HiGYP

    CellectaR

    I N N O V A T I O N I N I N S U L A T I O N

    ScreedBoard 28 Acoustic...

    3min 43sec

    ScreedBoard 20 Overlay...

    3min 27sec

    TETRiS Structural Flooring..

    5min 14sec

    Videos News RefurbNew Build More

    Cellecta App

    Installation animations

    Technical data sheets & brochures

    Comprehensive product info

    Latest Cellecta news

    CAD Drawings

    New

    Cellecta &

    The Environment

    Global

    Warming

    Potential

  • Part E Acoustic Building Regulations

    Cellectas refurbishment and conversion solutions guide demonstrates how a

    number of commonly found separating floor and wall constructions can have

    their acoustic performance upgraded with proven, cost effective treatments that

    will exceed the demanding acoustic legislative requirements.

    What do the Building Regulations require?

    To comply with current legislation, all separating floors and walls must be constructed in such a way as to

    achieve minimum prescribed acoustic values. Tests must be carried out by an accredited acoustic engineer

    to demonstrate compliance.

    Refurbishment and conversion projects

    Each construction element adopting exactly the same construction must be precompletion tested (PCT) by an

    accredited acoustician at a rate of 1:10.

    Building Regulation performance requirements

    New Build

    (1)

    Also relevant to Section 5 Noise of the Scottish Building Standards

    Airborne sound

    (Walls & floors)

    Impact sound

    (Floors)

    Change of use

    45 dB (D +C ) nT,w tr

    England & Wales

    Part requirements E E

    Historic Buildings

    With some historical buildings undergoing a material change of use it may not be practical to

    achieve the prescribed sound performance values. In these cases, Building Control bodies

    should be satisfied that everything reasonable has been done to improve the sound

    performance of the structure. PCT is normally required and the results submitted accordingly.

    Selecting the correct acoustic solution

    Each projects acoustic characteristics are different and should be assessed on an

    individual basis. Before a solution can be proposed, a number of important facts

    need to be established:

    Airborne sound tested to BS EN ISO 140-4 1998

    Impact sound tested to BS EN ISO 140-7 1998

    Precompletion testing (PCT)

    Once the information has been gathered, either select one of the solutions given on pages 4 16, or should

    the construction not be detailed, contact Cellectas technical team on 08456 717174 with the specific

    construction details.

    3

    Technical Advice 08456 71-71-74 [email protected]

    What element(s) are to be addressed: walls floors ceilings? 2

    What is the construction makeup of all the walls, floors and ceilings? 3

    4 Is the existing ceiling to be retained or upgraded?

    5 Are there restrictions on the height of the floor finish and ceiling depth?

    1 Is the proposed development deemed to be new build or change of use (including refurbishment)?

    New Build &

    conversionsTraditional buildings

    56 dB (D ) nT,w

    EScottish Building Standards

    Section 5: 2011

  • Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid on timber subfloor

    New ceiling fixed to resilient bars

    Item Material

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    1

    2

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Existing floorboards or new 18mm (min) tongue and groove chipboard floorboards screwed to joist

    200mm (min) timber floor joists at < 450mm centres

    Cell fon 50ecta Micro Slab sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    16mm metal resilient bar fixed perpendicular to floor joists at 400mm centres

    102

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the resilient bars

    Gaps filled with acoustic mastic sealant

    9

    11

    Cell fon 50ecta FS

    perimeter flanking strip, use to isolate plaster/plasterboard and the skirting from the YELO

    acoustic floorboard 6mm x 50mm x 30mm x 2000mm

    floating acoustic floorboard laid on a timber subdeck 28mm x 600mm x 1200mm Cell dB 28ecta Scree oard

    52dB

    Typical airborne(1)

    performance

    54dB

    (3)

    Fire resistance

    60min

    Typical impact(2)

    performance

    1

    2

    4

    5

    6

    7

    8

    9

    10

    11

    3

    5mm (min) gap between ceramic floor tiles and skirting board filled with flexible mastic3

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide, to ensure Building Regulations are achieved refer, to plasterboard manufacturers specifications.n,w tr

    NO

    SCREW

    S

    4

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    CellectaR

    4

    5

    6

    7

    8

    RF.01

  • Separating timber floors with brick or aggregate block masonry walls

    Resilient layer laid on a timber subfloor

    Underfloor heating system installed under low resistance floorboards

    New ceiling fixed to resilient bars

    Item Material

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Cell fon 8ecta

    high performance, acoustic fleece loose laid on subdeck 8mm x 600mm x 1200mm FIBRE

    Cell fon 50ecta Micro Slab

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    16mm metal resilient bar fixed perpendicular to floor joists at 400mm centres 10

    2

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the resilient bars 11

    Cell fon 50ecta FS

    perimeter flanking angle, use to isolate plaster/plasterboard and the skirting from the YELO

    acoustic floorboard 6mm x 50mm x 30mm x 2000mm

    low thermal resistance floorboard laid on a timber subdeck 20mm x 600mm x 1200mm Cell dB 20ecta Scree oard

    52dB

    Typical airborne(1)

    performance

    54dB

    (3)

    Fire resistance

    60min

    Typical impact(2)

    performance

    1

    2

    4

    5

    8

    9

    11

    12

    3

    5mm (min) gap between ceramic floor tiles and skirting board filled with flexible mastic

    NO

    SCREW

    S

    5

    Technical Advice 08456 71-71-74 [email protected]

    Side view

    6

    7

    10

    Gaps filled with acoustic mastic sealant12

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    Existing floorboards or new 18mm (min) tongue and groove chipboard flooring screwed to 200mm (min) timber joists

    Underfloor heating system routed or moulded insulation board loose laid on acoustic fleece

    1

    2

    4

    5

    6

    7

    8

    9

    3

    RF.02

  • Separating timber floors with aircrete block masonry walls

    Acoustic wall lining and acoustic floorboards laid on timber subfloor

    New ceiling fixed to deep resilient bars

    Cell fonecta Baffle stripsFIBRE

    (15mm x 75mm x 1200mm), stuck horizontally to the head and foot of the wall

    & vertically 600mm centres vertically with grab adhesive

    Existing floorboards or new 18mm (min) chipboard floorboards screwed to joist

    200mm (min) timber floor joists at < 450mm centres

    Cell 30ecta HP 30mm deep metal resilient bar fixed perpendicular to floor joists at 600mm (max) centres

    10

    2

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the resilient bars

    Gap filled with acoustic mastic sealant

    1

    9

    11

    floating acoustic floorboard laid on a timber subdeck 28mm x 600mm x 1200mm Cell dB 28ecta Scree oard

    Cell fon 50ecta FS perimeter flanking angle, used to isolate plaster/plasterboard and the skirting from the YELOacoustic floorboard 6mm x 50mm x 30mm x 2000mm

    3

    100mm (min) thick aircrete block wall (min 600Kg/m )

    3

    4

    5

    7

    8

    9

    10

    11

    2

    Cell fon 50ecta Micro Slab

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    50dB

    Typical airborne(1)

    performance

    53dB

    (3)

    Fire resistance

    60min

    Typical impact(2)

    performance

    Cell fon 30ecta TMFIBRE

    acoustic wall lining (30mm x 1200mm x 2400mm) fixed to wall with H GYPi

    acoustic fixings (8 x 105mm) at 600mm centres fixings Cell 105ecta AF

    2

    1

    6Side view

    CellectaR

    Item Material

    4

    5

    6

    7

    8

    3

    2

    NO

    SCREW

    S

    RF.03

  • Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid on timber subfloor

    New ceiling fixed to resilient bars

    ]

    1

    2

    3

    4

    5

    6

    7

    10

    Existing floorboards or new 18mm (min) tongue and groove chipboard floor boards, screwed to floor joist

    200mm (min) timber floor joists at < 450mm centres

    1

    2

    Cell fonecta

    perimeter flanking strip used to isolate plasterboard and skirting from the acoustic floor boardYELO

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    Cell fon 50ecta Micro Slab sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    Floating acoustic floorboard options (all installed on a timber subdeck):2

    17mm x 600mm x 2400mm (7.45kg/m ) + perimeter flanking strip17 fon 5/60 T ESYELO2

    26mm x 600mm x 2400mm (13.40kg/m )+ perimeter flanking angle T FS3026 fonYELO2

    30mm x 600mm x 2400mm (16.20kg/m )+ perimeter flanking angle T FS30 30 fonYELO

    Cellecta

    DECKfon

    16mm metal resilient bar fixed perpendicular to floor joists at 400mm centres

    9

    2

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the resilient bars

    Gap filled with acoustic mastic sealant

    8

    10

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    60min

    (3)

    Fire resistance

    17T 50dB

    26T 51dB

    30T 51dB

    Typical airborne(1)

    performance

    17T 56dB

    26T 57dB

    30T 56dB

    Typical impact(2)

    performance

    8

    9

    7

    Side view

    Technical Advice 08456 71-71-74 [email protected]

    CellectaR

    Item Material

    3

    4

    5

    6

    7

    RF.04

  • ]Existing floorboards or new 18mm (min) tongue and groove chipboard floorboards, screwed to floor joist

    200mm (min) timber floor joists at < 450mm centres

    2

    Metal frame (MF) ceiling system, 2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards

    1

    2

    5

    6

    7

    9

    perimeter flanking strip, used to isolate plaster and the skirting from the acoustic floorboardCell fonecta YELO

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid on timber subfloor

    Existing ceiling retained and new suspended ceiling added

    Service void

    60min

    1

    2

    4

    3

    8

    9

    6

    7

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    Existing plaster and lath ceiling, with any holes filled with suitable material

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)Cell fon 50ecta Micro Slab FIBRE

    Acoustic floorboard options (all installed on a timber subdeck):2

    28mm x 600mm x 1200mm (26.00kg/m ) + perimeter flanking angle

    Scree oard FSdB 28 fon 50 YELO

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    5

    (3)

    Fire resistance

    SB28 54dB

    17T 52dB

    26T 53dB

    30T 53dB

    Typical airborne(1)

    performance

    SB28 52dB

    17T 54dB

    26T 55dB

    30T 54dB

    Typical impact(2)

    performance

    8

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    100mm (min)

    CellectaR

    Item Material

    4

    3

    8

    Cellecta

    DECKfon

    2 17mm x 600mm x 2400mm (7.45kg/m ) + perimeter flanking strip17 fon 5/60 T ESYELO

    2 26mm x 600mm x 2400mm (13.40kg/m )+ perimeter flanking angle 26 fon 30T FSYELO

    2 30mm x 600mm x 2400mm (16.20kg/m )+ perimeter flanking angle 30 fon 30T FS YELO

    RF.05

  • Existing floorboards or new 18mm (min) tongue and groove chipboard floorboards, screwed to floor joist

    200mm (min) timber floor joists at < 450mm centres

    2

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards

    1

    2

    5

    6

    7

    9

    perimeter flanking strip, used to isolate plaster and the skirting from the acoustic floorboardCell fonecta YELO

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid on timber subfloor

    New suspended ceiling hung off floor joists

    60min

    1

    2

    4

    3

    8

    9

    6

    7

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    Metal frame (MF) ceiling system hung off floor joists. 100mm (min) below joists

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)Cell fon 50ecta Micro Slab FIBRE

    Acoustic floorboard options (installed on a timber subdeck):2

    28mm x 600mm x 1200mm (26.00kg/m ) + perimeter flanking angle

    Scree oard FSdB 28 fon 50 YELO

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved refer, to plasterboard manufacturers specifications.n,w tr

    5

    (3)

    Fire resistance

    SB28 53dB

    26T 52dB

    Typical airborne(1)

    performance

    SB28 53dB

    26T 56dB

    Typical impact(2)

    performance

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    100mm (min)

    CellectaR

    Item Material

    4

    3

    8

    2

    26mm x 600mm x 2400mm (13.40kg/m )+ perimeterCell fon 26 fon 30ecta T FSDECK YELOflanking angle

    9

    RF.06

  • Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid directly on timber subdeck

    Existing ceiling not disturbed

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (min 8kg/m )

    Cell fon 50ecta Micro Slab sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE2

    Existing plaster and lath ceiling (min 16kg/m ) or similar weight in plasterboards to provide fire integrity, fixed to the

    joists in a staggered formation.

    1

    Cell fon 15ecta Ultramat

    acoustic mat laid on existing floor boards 15mm x 1000mm x 1200mmDECK

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    1

    2

    4

    5

    3

    6

    45dB

    Typical airborne(1)

    performance

    59dB

    (3)

    Fire resistance

    30min

    Typical impact(2)

    performance

    Existing or new floorboards screwed to timber floor joists set at < 450mm centres

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    ! Do not secure the floating floor treatment to the deckCaution

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    CellectaR

    Item Material

    6

    2

    3

    4

    5

    10

    RF.07

  • 3

    100mm (min) thick masonry wall (min 1350Kg/m )

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (min 8kg/m )

    Cell fon 37ecta T structural acoustic floating floorboard laid directly on joists 37mm x 600 x 2400DECK

    Cell fon 50ecta Micro Slab

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    16mm metal resilient bar fixed perpendicular to floor joists at 400mm centres

    8

    2

    2 layers of 15mm sound block (12.5kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the resilient bars

    Acoustic mastic sealant

    1

    2

    7

    9

    Cell fon 5/100ecta ES perimeter flanking strip, use to isolate plaster/plasterboard and skirting from the YELOacoustic floorboard

    200mm (min) timber floor joists at < 450mm centres

    2

    3

    4

    5

    9

    6

    7

    8

    52dB

    Typical airborne(1)

    performance

    53dB

    (3)

    Fire resistance

    60min

    Typical impact(2)

    performance

    1

    Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid directly on timber floor joists

    New ceiling fixed to resilient bars

    ! Do not secure the floating floor treatment to the joistsCaution

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    Technical Advice 08456 71-71-74 [email protected]

    Side view

    CellectaR

    Item Material

    3

    4

    5

    6

    11

    RF.08

  • 213mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    1

    2

    Cell fon 5/120ecta ES

    perimeter flanking strip, used to isolate plaster/plasterboard and skirting from the YELO

    acoustic floorboard

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid directly on timber floor joists

    Existing ceiling not disturbed joist fire resistance upgraded

    1

    2

    3

    4

    5

    8

    9

    7

    6

    ! Do not secure the floating floor treatment to the joistsCaution

    Cell fon 50ecta Micro Slab

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    92

    Existing plaster and lath ceiling (min 16kg/m ) or similar weight in plasterboards to provide fire integrity,

    fixed to the joists in a staggered formation.

    100mm wide strips of 12.5mm glass reinforced gypsum board fire protection strips mechanically fixed to both

    sides of the floor joists

    Sheet of 12.5mm glass reinforced gypsum board cut to suit gap between joists, laid on fire protection strips

    200mm (min) timber floor joists at < 450mm centres

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    (3)

    Fire resistance

    60min

    Q39 49dB

    Q45 49dB

    Typical airborne(1)

    performance

    Q39 59dB

    Q45 58dB

    Typical impact(2)

    performance

    12

    structural acoustic floating floorboard laid directly on joists39mm x 600 x 2400Quattro 39f

    structural acoustic floating floorboard laid directly on joists45mm x 600 x 2400Quattro 45f

    Cell fonecta DECK

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    CellectaR

    Item Material

    3

    7

    8

    5

    6

    4

    RF.09

  • Item Material

    2

    13mm thick plaster or 12.5mm plasterboard on dabs (8kg/m )

    Cell fon 5/120ecta ES

    perimeter flanking strip, use to isolate plaster/plasterboard and skirting fromYELO

    acoustic floorboard

    3

    100mm (min) thick masonry wall (min 1350Kg/m )

    Separating timber floors with brick or aggregate block masonry walls

    Acoustic floorboards laid directly on timber floor joists

    Existing ceiling not disturbed

    1

    2

    3

    4

    5

    6

    (3)

    Fire resistance

    60min

    ! Do not secure the floating floor treatment to the joistsCaution

    7

    98

    Existing plaster and lath ceiling

    Cell fon 50ecta Micro Slab

    sound absorption material fitted between floor joists 50mm (t) x 400mm (w)DECK

    200mm (min) timber floor joists at < 450mm centres

    (1) (2) (3)

    L value. Rw + C value. Fire resistance stated is given as a guide. To ensure Building Regulations are achieved, refer to plasterboard manufacturers specifications.n,w tr

    2

    2 layers of 12.5mm fire boards (9.8kg/m each) or similar plasterboards to provide fire integrity, fixed in a

    staggered formation to the floor joists

    Galvanised chicken wire mechanically fixed to the underside of the existing ceiling

    9

    Q39 49dB

    Q45 49dB

    Typical airborne(1)

    performance

    Q39 59dB

    Q45 58dB

    Typical impact(2)

    performance

    Cell fonecta DECK

    Technical Advice 08456 71-71-74 [email protected]

    CellectaR

    structural floating floor treatment laid directly on joists 39mm x 600 x 2400Quattro 39f

    structural floating floor treatment laid directly on joists 39mm x 600 x 2400Quattro 45f

    1

    2

    3

    4

    7

    8

    5

    6

    13

    RF.10

  • 21

    Item Material

    15mm thick service void

    Cell fonecta Baffle Strips sound absorption strips 15mm x 75mm x 1200mmFIBRE

    2

    12.5mm (8kg/m ) plasterboard on dabs

    1

    2

    6

    7

    Cell fonecta TM 2

    composite acoustic wall lining 30mm x 1200mm x 2400mm (15.00kg/m )FIBRE H GYPi 30

    3

    100mm (min) thick masonry wall brick, concrete block or aircrete block (min 600Kg/m )

    13mm (min) plaster finish

    Wall floor junction detail Wall ceiling junction detail

    100 100100mm 10045 4545 100 100100 45

    MW.1 MW.3 MW.4

    Brick, aggregate or aircrete block separating/partition walls

    Semiindependently fixed composite acoustic wall lining

    2

    Acoustic wall lining secured to the wall with acoustic fixings (8mm x 105mm) 12 per sheet (min)Cell 105ecta AF

    6 7 2

    13 13252525

    Cell 38ecta AT acoustic edge strip used to isolate wall lining from adjoining floor, walls and ceiling

    CellectaR

    4

    5

    3 331

    52dB

    46dB

    10dB

    50dB

    43dB

    7dB

    51dB

    44dB

    8dB

    50dB

    43dB

    7dB

    Rw

    R + Cw tr

    38dB

    36dB

    BaseMW.1 MW.2 MW.3 MW.4partition

    Typical airborne performance

    Improvement over

    base partition R + Cw tr

    Technical Advice 08456 71-71-74 [email protected]

    1

    Base wall

    Patent Pending Acoustic System

    7116 26

    5

    4

    5

    4

    5

    4

    5

    4

    3

    8

    3

    8888

    14

    MW.2

  • Item Material

    89mm (min) x 38mm timber stud wall set at 600mm (max) vertical centres

    Cell fonecta TM 2 composite acoustic wall lining 30mm x 1200mm x 2400mm (15.00kg/m )FIBRE H GYPi 30

    16mm thick metal resilient bar fixed to metal studs at 600mm (max) horizontal centres

    1

    2

    Cell fon 15ecta Micro Slab 15mm x 600mm x 1200mmFIBRE

    2

    12.5mm (min) thick plasterboard (8Kg/m )

    Cell 38ecta AT acoustic edge strip used to isolate wall lining from adjoining floor, walls and ceiling

    Wall floor junction detail Wall ceiling junction detail

    4 4 2

    7

    TW.3 TW.4

    Timber stud separating/partition walls

    Semiindependently fixed composite acoustic wall lining

    4689114mm 114 126 8946 4646 46 46

    1 2 1 2

    7

    41 2 4 4 2 41

    Sound absorption material fitted between timber studs:

    2550mm mineral wool acoustic partition roll (APR)

    Cell fon 15ecta Micro Slab fitted between resilient bars 15mm x 600mm x 1200mmFIBRE

    Cell fon 50ecta Micro Slab sound absorption material fitted between floor joists 50mm (t) x 400mm (w)FIBRE

    54dB

    45dB

    14dB

    58dB

    49dB

    18dB

    60dB

    52dB

    20dB

    56dB

    49dB

    16dB

    Rw

    R + Cw tr

    40dB

    35dB

    BaseTW.1 TW.2 TW.3 TW.4

    30 minutes

    30 minutes

    30 minutes

    30 minutes

    30 minutes

    Fire resistance

    partition

    Typical airborne performance

    Fire resistance

    Improvement over

    base partition R + Cw tr

    CellectaR

    7

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    Base wall TW.1 TW.2

    66 85 65 6 6 68

    7

    3

    4

    5

    6

    7

    8

    15

    333

  • 95mm 82 70 3030 30 70 4625 70 3042

    Wall floor junction detail Wall ceiling junction detail

    SW.1 SW.3 SW.4

    1

    Metal frame separating/partition walls

    Directly/semiindependently fixed composite acoustic wall lining

    5

    Item Material

    70mm (min) metal C studs set at 600mm (max) vertical centres

    Cell fonecta TM 2 composite acoustic wall lining 30mm x 1200mm x 2400mm (15.00kg/m )FIBRE H GYPi 30

    16mm thick metal resilient bar fixed to metal studs at 600mm (max) horizontal centres

    1

    2

    FIBREfon 15 15mm x 600mm x 1200mmMicro Slab

    2

    12.5mm (min) thick plasterboard (8Kg/m )

    Cell 38ecta AT acoustic edge strip used to isolate wall lining from adjoining floor, walls and ceiling

    Sound absorption material fitted between metal studs:

    25 mineral wool acoustic partition roll (APR)

    Standard

    partition

    1 2 1 2 222

    66 6

    48dB

    45dB

    5dB

    55dB

    46dB

    12dB

    55dB

    46dB

    12dB

    53dB

    45dB

    10dB

    Rw

    R + Cw tr

    43dB

    34dB

    BaseSW.1 SW.2 SW.3 SW.4

    30 minutes

    30 minutes

    30 minutes

    30 minutes

    30 minutes

    Fire resistance

    partition

    Typical airborne performance

    Fire resistance

    Improvement over

    base partition R + Cw tr

    Technical Advice 08456 71-71-74 [email protected]

    SW.2

    CellectaR

    3

    4

    5

    6

    31 4 4 4 4 44 3333

    16

  • Lightweight partitions built off the

    floor joistsStairwell/

    communal area

    Bath and shower trays Sanitary ware Metal frame partition built off the

    structural floor

    Timber stud partition 3 31b

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    Lightweight internal walls built off the structural

    floor must be isolated from the acoustic

    floorboards with YELOfon ES or FS strip.

    Leave a 510mm expansion gap between the habitable area acoustic floorboards and the communal area floor treatment.

    Door thresholds

    Baths and shower trays should be built off a

    structural floor and MUST be isolated from the

    acoustic floorboards and any floor finished. Any

    gaps should be sealed with a suitable mastic.

    Sanitary ware should be built off a structural floor

    and MUST be isolated from the acoustic

    floorboards and any floor finished. Any gaps should

    be sealed with a suitable mastic.

    Lightweight internal walls built off the floor joists

    MUST be isolated from the acoustic floorboards

    with YELOfon ES or FS strip.

    Wall treatments MUST be isolated from the

    acoustic floorboards with YELOfon ES or FS strip,

    and all gaps sealed with a suitable mastic.

    Wall treatments MUST be isolated from the

    acoustic floorboards with YELOfon ES or FS strip,

    and all gaps sealed with a suitable mastic. .

    Lightweight internal walls should be built off the

    structural floor deck and MUST be isolated from

    the acoustic floorboards with YELOfon ES or FS

    strip.

    1a

    YELOfon ES or FS flanking strip

    MUST be placed around floor

    perimeter, including around all

    walls that are built off the

    structural floor

    Stairwell /

    communal

    area

    Wall treatment installed before the

    floor treatment

    Wall treatment installed after the

    floor treatment

    The acoustic performance of the floor structure will be compromised if the acoustic floorboard is not completely

    isolated from the timber joists, subfloor, services, door frames, surrounding walls and their treatments. To address

    this risk, each potential problem area needs to be detailed accordingly.

    Design & installation details CellectaR

    31b 31b32

    353531b3431b33

    353831b37336

    1

    2

    8

    3

    4

    5

    67

    17

    CellectaR

    I N N O V A T I O N I N I N S U L A T I O N

    ScreedBoard 28 Acoustic...

    3min 43sec

    ScreedBoard 20 Overlay...

    3min 27sec

    TETRiS Structural Flooring..

    5min 14sec

    Videos News RefurbNew Build More

    Cellecta App

    Installation animations

    Technical data sheets & brochures

    Comprehensive product info

    Latest Cellecta news

    CAD Drawings

    New

  • Scree oard dB 28

    ScreedBoard 28 is the ultimate acoustic overlay treatment. Its

    high density and unique resilient layer provides outstanding

    acoustic performance.

    lOnly 28mm thick

    lHard wearing looks and feels like screed

    lInterlocking edges no need for screws

    lEasy to cut to size and install

    lAccepts ceramic tiles*

    Overall board thickness:

    Facing thickness:

    Resilient layer thickness:

    Board dimensions:

    Edge Profile:

    Weight:

    Fixings required:

    Jointing adhesive:

    Perimeter edge strip:

    28mm

    20mm ScreedBoard

    8mm 70% recycled polyester (PES)

    600mm x 1200mm

    Interlocking tongue & groove2

    18.62kg per sheet 26kg/m

    None2

    SB adhesive (33m per 1Ltr bottle)

    YELOfon FS50

    High Density Acoustic Floorboard

    Scree oard dB 20

    ScreedBoard 20's high density and very low thermal resistance

    give it a quick heat response time, making it the ideal floorboard

    for underfloor heating systems.

    lOnly 20mm thick

    lHard wearing looks and feels like screed

    lInterlocking edges no need for screws

    lExceptionally low thermal resistance

    lAccepts ceramic tiles*

    Board thickness:

    Board dimensions:

    Edge Profile:

    Weight:

    Thermal resistance:

    Fixings required:

    Jointing adhesive:

    Perimeter edge strip:

    Associated resilient layer:

    20mm

    600mm x 1200mm

    Interlocking tongue & groove2

    18.00kg per sheet 25kg/m2

    0.04m /kW

    None

    SB adhesive 2

    (33m per 1Ltr bottle)

    YELOfon FS50

    FIBREfon 8 8mm x 600mm x

    1200mm >70% recycled PES

    High Density, Low Thermal Resistance Floorboard

    Made from recycled &

    Recyclable Materials

    Global

    Warming

    Potential0

    Recycled &

    Recyclable Material

    Global

    Warming

    Potential0

    Product Information

    *Screedboards should be sealed with SB Primer prior to adhering ceramic tilesFIBRE

    fon fon H GYPi TM30

    FIBREfon HiGYP 30TM high density acoustic wall boards dramatically

    reduce airborne sound transmission through all types of existing and

    new build timber stud, metal frame and masonry walls.

    lOnly 30mm thick

    lExcellent acoustic performance

    lHigh density plasterboard facing

    lEasy to cut to size and install

    Made from

    Recyclable Materials

    Global

    Warming

    Potential0

    Board dimensions:

    HiGYP thickness:

    Absorption layer thickness:

    Edge profile:

    Weight:

    Fixing required:

    30mm x 1200mm x 2400mm

    15mm

    15mm

    Square edge (SE) or tapered edge (TE)2

    10.74kg per sheet 7.45kg/m

    Cellecta AF/105 acoustic fixings

    (8mm x 105mm) 12per sheet (min)

    Acoustic Wall Lining FIBRE

    fon fon Baffle Strips

    FIBREfon patent pending Baffle Strips are used to isolate FIBREfon

    HiGYP 30TM acoustic boards from the structure wall and absorb

    airborne sound within the service cavity.

    lOnly 15mm thick

    lExcellent acoustic performance

    lProduce cavity to run services

    Easy to cut to size and install

    Made from

    Recyclable Materials

    Global

    Warming

    Potential0

    Baffle size:

    Composition:

    Fixing adhesive:

    15mm (t) x 75mm (w) x 1200mm (l)

    Recyclable wood fibre board

    Acoustic mastic or grab adhesive

    Acoustic Baffle Strips

    CellectaR

    NO

    SCREW

    SNO

    SCREW

    S

  • DECKfonfonUltramat 15

    DECKfon Ultramat 15 high performance underlay is a quick and

    easy to lay treatment that will improve the airborne and impact

    performance of a floor where there is limited room height.

    Only 15mm thick

    Easy to cut to size with a sharp knife

    Overall matt thickness:

    Facing:

    Resilient core thickness:

    Matt dimensions:

    Weight:

    Perimeter edge strip:

    15mm

    Rubberised polymer with fillers

    9mm

    1000mm x 1200mm2

    12.00kg per sheet 10kg/m

    None required

    High Density Acoustic Mat

    FIBREfon Micro Slabs unique soft touch microfibres give the

    product very high sound absorption properties. It will be fitted

    between joists, in ceiling cavities and partition voids.

    Available in two thickness: 15 & 50mm

    Only half the thickness required compared to traditional

    mineral wool to achieve the same acoustic performance

    Itchfree fibres

    Supplied precut to suit each application

    Made from 70%

    Recycled Materials

    Global

    Warming

    Potential0

    Thickness available:

    Slab dimensions:

    Composition:

    15mm & 50mm

    15 600mm x 1200mm

    50mm 400mm x 7.20m (3 slabs per pack)

    70% (min) recycled polyester micro fibres

    High Performance Sound Absorbing Slab

    FIBREfonfon Micro Slab 15 50&

    itch

    free

    Made from

    Recycled Materials

    Global

    Warming

    Potential0

    Technical Advice: 08456 71-71-74 [email protected]

    19

    DECKfon fon 17 26 30T T T, &

    DECKfon overlay treatments are designed to improve the acoustic

    performance of a decked timber floor where a new ceiling is to

    installed.

    lThree thickness available: 17, 26 & 30mm

    lMoisture resistant floorboard

    lEasy to cut to size and install

    Overall board thickness:

    Facing thickness:

    Resilient layer thickness:

    Board dimensions:

    Edge Profile:

    Weight:

    Perimeter edge strip:

    17mm, 26mm & 30mm

    17T: 9mm MR MDF,

    26T: 18mm P5 Chipboard.

    30T: 22mm P5 chipboard

    8mm open cell polyurethane

    600mm x 2400mm

    Tongue & groove2

    17T: 10.74kg per sheet 7.45kg/m 2

    26T: 19.29kg per sheet 13.40kg/m 2

    30T: 23.32kg per sheet 16.20kg/m

    17T: YELOfon ES5/60

    26T & 30T: YELOfon FS30

    Acoustic Overlay Floorboards

    DECKfon fon 37 39 45T Quattro , &

    DECKfon structural treatments are designed to be laid directly on

    the floor joists. 37T will improve the acoustic performance for

    timber floor where a new ceiling is to be installed and Quattro 39

    or 45 where an existing ceiling is to be retained.

    lThree thickness available: 37, 39 & 45mm

    lMoisture resistant chipboard

    lEasy to cut to size and install

    Overall board thickness:

    Facing thickness:

    Board dimensions:

    Edge Profile:

    Weight:

    Perimeter edge strip:

    37mm, 39mm & 45mm

    37T: 22mm P5 Chipboard

    Q38 & Q45: 18mm P5 Chipboard

    600mm x 2400mm

    Tongue & groove2

    37T: 24.76kg per sheet 17.20kg/m 2

    Q39: 27.64kg per sheet 19.20kg/m 2

    Q45: 28.80kg per sheet 20.00kg/m

    37T: YELOfon ES5/100

    Q39 & Q45: YELOfon ES5/120

    Structural Deck Acoustic Floorboards

    Made from recycled &

    Recyclable Materials

    Global

    Warming

    Potential0

    Made from recycled &

    Recyclable Materials

    Global

    Warming

    Potential0

    CellectaR

  • 20

    Technical Advice 08456 71-71-74 www.cellecta.co.uk

    ! Failure to install a perimeter flanking strip correctly will result in acoustic failureCaution

    The acoustic efficiency of the floor or wall will be adversely affected should acoustic bridging between the

    acoustictreatment and the surrounding structures occur (known as flanking transmission).

    All floor finishes must be isolated from the surrounding walls (including plaster finish and skirting boards), door

    linings, services and other structural elements.

    To address acoustic flanking, Cellecta manufactures an extensive range of flexible extruded polyethylene

    edge strips to suit each specific treatment.

    Eliminating Acoustic Flanking

    Acoustic treatment Flanking strip required Flanking strip dimensions

    YELOfon 5/100ES

    YELOfon 5/60ES

    YELOfon 5/120ES

    YELOfon 30FS(Profiled flanking strip)

    YELOfon 50FS(Profiled flanking strip)

    Cell 38ecta AT

    (Self adhesive acoustic tape)

    5mm (t) x 100mm (h) x 50m (L)

    5mm (t) x 60mm (h) x 50m (L)

    5mm (t) x 120mm (h) x 50m (L)

    6mm (t) x 30mm (w) x 30m (h) x 2000mm (L)

    6mm (t) x 50mm (w) x 30m (h) x 2000mm (L)

    2.5mm (t) x 38mm (w) x 40m (L)

    DECKfon 37T

    DECKfon 17T

    DECKfon 26T

    DECKfon 30T

    Scree oard dB 28

    H GYPi 30TM

    Note. All Cellecta edge strips have a global warming potential (GWP) of

  • Tools & Accessories

    ScreedBoard Fixing Batten

    ScreedBoard Pull Bar

    SB Adhesive 1 litre bottle2

    Coverage: 33m /ltr of ScreedBoard

    Cellecta fon Adhesive 1 litre bottle2

    Coverage: 33m /ltr of acoustic boards

    ScreedBoard Primer 5 litre bottle

    Use to seal the Screedboards prior to

    adhering ceramic tiles

    Cellecta HP30 Deep Resilient Bar

    Size: 30mm deep x 3000mm long

    Installation centres: > 600mm centres

    The resistance to airborne sound depends mainly on the mass per unit area of the structural floor and supporting

    walls, and partly on the ceilings construction. It is therefore important to choose a ceiling treatment that

    complements the performance of the chosen structural floor, to produce an overall structure that exceeds the

    required values. Decoupling the ceiling from the structural floor is an effective way of reducing the contact path

    that impact sound can follow. Adding mass in the way of plasterboard to the floor structure and filling the ceiling

    void with a mineral wool will also improve the acoustic performance of the structure.

    Detailed below are for four types of ceiling treatments available in order of performance:

    Ceiling Treaments

    Notes. Further guidance is given in Approved Document E and the manufacturer of the proposed ceiling system. Professional advice should be sought

    to ensure the overall floor construction complies with current fire regulations.

    2: Proprietary metal frame suspended ceiling system

    Cavity filled with 50mm FIBREfon Micro Slab 50 or3

    100mm mineral wool (45kg/m ).

    1: Independent ceiling

    Cavity filled with 50mm FIBREfon Micro Slab 503

    or 100mm mineral wool (45kg/m ).

    3: Plasterboard on Cellecta HP30 deep resilient bars

    Cavity filled with 50mm FIBREfon Micro Slab 503

    or 100mm mineral wool (45kg/m ).

    4: Plasterboard on proprietary shallow resilient bars

    Cavity filled with 50mm FIBREfon Micro Slab 50 or 3

    100mm mineral wool (45kg/m ).

    Up to 450mm centres

    Up to 600mm centres

    Technical Advice 08456 71-71-74 [email protected]

    CellectaR

    21

  • Construction Information & Notes

    Further Information CellectaR

    External wall type:

    New Build Refurbishment/conversionType of project: Mixed development

    Brick/ dense block with cavity Brick/aircrete block with cavity Solid 9" Brick/dense block

    Other (details)

    Internal wall type: Brick/ dense block Timber stud Metal frame

    Floor type: Solid timber joists Other (details)

    Ceiling: Existing ceiling to be retained New ceiling to be installed

    Proposed ceiling construction:

    Further information:

    Floor depth: mm

    Aircrete block

    Wall finish: Plastered None Other (details)Plasterboard on dabs

    Installation

    Cellecta acoustic insulation products are supplied with

    detailed fixing instructions. For further assistance contact

    Cellectas technical team on Tel. 08456 717174.

    Architectural Drawings

    Architects and designers can quickly and easily insert

    Cellectas insulation products into their drawings by

    downloading the specific FASTRACK detail in dwg CAD

    format from Cellectas website.

    Specification Clauses

    Specifiers can quickly and easily insert Cellectas

    insulation products into their specification document by

    downloading the relevant RIBA NBS Plus clause from

    Cellectas website (www.cellecta.co.uk).

    Health and Safety

    Copies of COSHH data for all Cellecta products are

    available upon request.

    Packaging

    Cellecta acoustic boards are strapped and shrink

    wrapped on wooden pallets with corner protectors. Micro

    slabs are suppled in polythene bags.

    Onsite handling & storage

    Cellecta acoustic boards must be stored on level ground, in a

    dry environment, undercover and not sheeted outside.

    Technical Advice 08456 71-71-74 [email protected]

    Notes

    Cellecta reserves the right to amend product specifications without prior notice. Colours shown are for illustration purposes and are subject to production

    variation. Product technical data stated is typical. The information included in this guide is based on Cellectas experience and is believed to be reliable. dB values

    quoted and applications illustrated are typical, however, each sites characteristics are different and as a result, reliance should not be solely placed upon the

    recommendations detailed.

    Cellecta, as the manufacturer, has no control over the installation of its products. The purchaser should evaluate the product's suitability and is responsible for

    adhering to any laws or regulations in this respect, making the purchaser also liable for observing any third party rights.

    22

  • Other Products Available From Cellecta

    Technical Advice 08456 71-71-74 [email protected]

    23

    YELO 10fon fon HD + System

    YELO HD10+ is the acclaimed high density, closedcell resilient layer system (YELO HD10+, fon fon

    Estrip and Jstrip) that carries its own proprietary Robust detail EFC5. The lightweight, easy to

    install system delivers unrivalled acoustic performance when used to isolate a floating screed from

    a structural concrete separating floor.

    Superior impact sound deadening properties

    Suitable for all types of concrete floors and screeds

    Lightweight, easy to cut and install rolls

    Robust detail treatment (EFC5) 2

    Over 5,000,000m successfully installedRecyclable Material

    Global

    Warming

    Potential

  • Technical Helpline:Technical, installation advice,

    site surveys and takeoff service

    T: 08456 717174

    F: 08456 717172

    E: [email protected]

    Unit D Norman Close

    Rochester

    Kent

    ME2 2JU

    T. 08456 717174

    F. 08456 717172

    E: [email protected]

    www.cellecta.co.uk

    CellectaI N N O V A T I O N I N I N S U L A T I O N

    R

    ARB/612/V2

    FASTRACKCADARCHITECTURAL CAD DATABASES

    R

    Plus