ceiling fixer note - joondalup.wa.gov.au
TRANSCRIPT
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:SHEET: 1 of 7
© copyright
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING:
48.80%
R20/25
SITE AREA: 350m²
Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:1, 1:100, 1:200
21003
28x
1450
2434x3610 Stacking Door
28x2410
8x1
450
F 8
x301
0 F
9x1
810
820Alum.
6x2
410
28c-7.5b A
28x
610
F
1200 alum.
20x
850
F 2
0x85
0 F
6x7
30 A
OBS
integr/hood
gas hpubo
1 2 3 4 5 6 7 8
91011
1213
UP
Remote controlSectional door
ManualRoller door
820
820
720wc
720720wc
720
720
f/wall lintelBWK @ 28c
720
720
28c
high
slid
ers
w/-
bul
khea
d ov
er
WM
MH
Gas/ElecComb m/box
PCD
fw
fwfw
1,500 30 12,160 1,4002,160 600 4,270 4,530 600
350 1,810 600 425 3,845sl.door
1,060 2,410win
1,060 600
1,500 30 12,160 1,400960 6,300 1,300 3,000 600
960 590 5,120garage door
590 1,260 40 595 1,810win
595 600
5,00
019
,750
1,00
0
5,00
019
,750
1,00
050
03,
090
15,1
6599
5
500
340
2,41
0w
in34
04,
580
1,09
01,
650
win
865
3,01
0w
in1,
150
1,81
0w
in1,
010
690
305
500
1,00
05,
090
1,99
01,
540
590
5,64
52,
400
995
500
1,00
05,
090
1,99
01,
450
win
9059
039
073
0w
in
420
850
win
1,92
585
0w
in48
02,
400
690
305
E2
E3
E4
E1
inst.hwu inrecessed box
plumbing ductswith access panels
plumbing ductswith access panels
230w 'T' lintel@ 26c
spandrel end
190w 'T' bar @ 25c
line of upperfloor over
recessed shr. floor
prelay conduit
lintel @ 27c
alcor flashing topier closing cavity
alcor flashing topier closing cavity
lintel @ 27c
handrail &balustradeto NCC
drywall
a/c peno. above
a/c peno. above
insect proof wall ventsfor exhaust fans
insect proof wall ventsfor exhaust fans
framed b'head@ 2400afl
drywall
1600 x 600concrete a/cplinth @ -1c
beam as pereng. details
RWH w/- o'flow
'T' bar @ 28c'T' bar @ 28c
'T' bar @ 28c
SC
SC'T' lintel to eng.details
beam
665x565lockable MH
810x110a/c vent
GARAGE
ENT
POR
GUESTBED
OFFICE
sh &
rail 28c CL
31c CL
31c CL
30c CL
downturn beam to eng.details
28c bulkhead
L'DRY31c CL
WIL
SCULL.
fr rec
4x shelves
4x shelves
KITCHEN
DINING31c CL
LIVING31c CL
ALFRESCO
ENS 2
PDR
tiled
tiled tiled
28c CL
28c CL
27c dropped CL
recessed sill
31c CL
31c CL
tap
tap-1c b'paved
30c CL
dw
grano @ -01c
-01c b'paved
3c slab
over
34c
gutte
r on
2c fa
cebr
ick b
ound
ary
wall w
/-ph
ysica
l ter
mite
bar
rier
PWP
PWP
PWPs
beam
beam
beam
STR
2c conc.plinth
Area Calc......
PORCHALFRESCOBALCONYGARAGEUPPER FLOORGROUND FLOOR
1.6314.6912.8742.30106.31129.57307.37 m²
W
S
E
N
GROUND FLOOR PLAN1:100 TOTAL
CEILING FIXER NOTE- Square set cornice to areas with 28c CL to suit 2340 internal door frames
NOTE- Internal doors to2340mm high U.O.N.
OPEN SPACE
SITE AREA: 350m2HOUSE FOOT PRINT: 170.79m2
OPEN SPACE: 51.20%
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:SHEET: 2 of 7
© copyright
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING:
48.80%
R20/25
SITE AREA: 350m²
Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:100, 1:1, 1:200
21003
3 4 5 6 7 8
91011
1213141516DN
9x610 F2400x2890SD
28x
SP A
20x850 A 2400x2170SD
17x
1570
15x
1210
OBS
9x6
10 A
OBS
9x8
50 F
20x
850
A
9x1690
9x3
010
9x6
10 F
9x2
290
F 9
x217
0820
820
820
720
820
720wc
F/H
slid
ers
toco
rnic
e so
ffit
720wc
720
F/H sliders tocornice soffit
9x610 AOBS
16x1570OBS
fw
fw
fw
fw
MH
E2
E3
E4
E1
3,00
014
,000
8,75
0
3,00
014
,000
8,75
0
1,500 2,790 8,800 2,000
1,500 2,790 8,800 2,000
4,170 4,630
1,012win
738 2,170sl.door
250 3,055sl.door
803 772win
1,00
02,
140
10,8
60
1,00
02,
140
win
1,01
2w
in2,
508
850
win
535
610
win
675
1,21
0w
in94
51,
570
win
945
1,00
013
,000
1,00
077
2w
in3,
293
2,29
0w
in49
03,
010
win
3,14
5
8,800
1,125 1,690win
2,535 610win
1,040 1,570win
230
3,00
0
2,000
8,75
0
2,790
handrail &balustradeto NCC
handrail &balustradeto NCC
struct.column
struct.column
struct.column
handrail &balustrade
to NCC
100x100 SHS
recessedshr. floor
recessedshr. floor
pitching beamspitching beam
POP overflow
190wparapet@ 40c
190wparapet@ 37c
550x550 wall peno.into lower roof space
extent of lower floor
drywall
roof vent
roofvent
roof vent
roof vent
RWH w/- o'flow
RWH w/-o'flow
struct.column
100x100 SHS
sh & rail
4x sh
elves
WIL
BED 3 sh &
rail
31c CL
BED 2
SITTING
BED 1
WIR
WC
ENS
BATH
BALCONY31c CL
tiled 32c
tiled
tiled
tiled
tiled
sh & rail
a/c
1165 x 565frame-out in ceilingfor a/c return air
2000x2000x600fan coil clearancein roof
a/c31c CL
31c CL
31c CL
31c CL
31c CL31c CL
31c CL
31c CL
beam
beam
beam
beam
beam
beam
beam
PWP
PWP
PWP
2000h x 650wtiled wall
Area Calc......
PORCHALFRESCOBALCONYGARAGEUPPER FLOORGROUND FLOOR
1.6314.6912.8742.30106.31129.57307.37 m²
TRTF[[
10.0010.00
]]
Top RetainingTop Fence
W
S
E
N
FIRST FLOOR PLAN1:100
TOTALNOTE- Internal doors to
2340mm high U.O.N.
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:
© copyright
SHEET: 3 of 7Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:100
21003
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING: R20/25
SITE AREA:
48.80%
350m²
10.22
10.43
9.90
9.91
NGL
2657
F.L 0c
171
C.L 31c
2692
F.L 33c
C.L 64c+ PLATE
26c
40c
61c
52c 52c
37c 30c 32c
30c
40c
52c
41c
52c
61c
balustrade &handrail to NCC
metal roof sheetingat 24°43' pitch
contrastingcolour
'T' lintel @ 26c
100x100 SHScap flashing
cap flashing
shelf lintel @ 30cto engineers details
100x100 SHS
render
auto sectional door
9.76
9.69
9.87
9.74
9.7510.43
2657
F.L 0c
171
C.L 31c
2692
F.L 33c
C.L 64c+ PLATE
9c 3c
15c
18c
28c
61c
31c 30c
61c
37c
33c
52c
28c 28c
0c
inst. HWU inrecessed box plumbing ducts with access panels
metal roof sheetingat 20°49' pitch
metal roof sheetingat 24°43' pitch
metal roof sheetingat 3°26' pitch
spandrel endraking barge & capping
cap flashing
renderedbrick pier
flashing'V' groove
render
render
pcd
NGL
E1 FRONT ELEVATION1:100
E2 SIDE ELEVATION1:100
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:
© copyright
SHEET: 4 of 7Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:100
21003
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING: R20/25
SITE AREA:
48.80%
350m²
9.76
9.76
9.71 NGL
2657
F.L 0c
171
C.L 31c
2692
F.L 33c
C.L 64c+ PLATE 61c
40c
28c
61c
25c 28c
31c
metal roof sheetingat 20°49' pitch
raking barge& capping
flashing
metal roof sheetingat 24°43' pitch
renderedbrick pier
renderedbrick pier manual roller door
'T' bar @ 25c
'T' bar @ 28c
rwh w/- o'flow
cap flashingflashing
obs obs
render
render
9.72
9.71
9.75
9.76
9.75 NGL
2657
F.L 0c
171
C.L 31c
2692
F.L 33c
C.L 64c+ PLATE 61c
40c
30c 28c
8c 0c
61c
34c 33c
31c 28c
18c
3c
15c
28c
0c
8c
32c
52c
28c
plumbing ductswith access panels
metal roof sheetingat 20°49' pitch
metal roof sheetingat 24°43' pitch
metal roof sheetingat 3°26' pitch
renderedbrick pier
'T' bar @ 28c
100x100 SHS
comb. gas/elec. meterbox
cap flashing
balustrade &handrail to NCC
shelf lintel @ 30cto engineers details
insect proof wall ventsinsect proof wall vents
contrasting colour
obs obs
flashing
2c face brick to boundary wallrender
obs
'V' groove
E
G
E3 REAR ELEVATION1:100
E4 SIDE ELEVATION1:100
PROPOSED RESIDENCE ADDRESS:
FOR:
AMENDMENTS:
CONTRACT NO:
SIGNATURES:
OWNER:
OWNER: _____________________
BUILDER:
DATE:
_____________________
_____________________
H:\_OneDrive\OneDrive\03. WORK\CONTRACT WORK\COAST HOMES\Coast Homes WORK\VARIATIONS\Roebuck\21003 Roebuck Contract Drawings.pln
SCALE:DATE:DRN:SHEET: #LayNoInSubset of 15_____________________
© copyright
Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR
12/08/2021
1:100
21003
28x
1450
2434x3610 Stacking Door
28x2410
8x1
450
F 8
x301
0 F
9x1
810
820Alum.
6x2
410
28c-7.5b A
28x
610
F
1200 alum.
20x
850
F 2
0x85
0 F
6x7
30 A
OBS
47.1
5
90 °0 '0 "
15.0990 °0
'0 "
47.1
5
9.7
4
9 .79
9 .76
9.76
9.6
91
0.1
7
9.74
9 .76
9 .87
9 .78
9 .74
9 .74
9 .75
9.9
8
9 .76
9.73
9.7
4
9.77
10 .22 1 0 .4
3
10
.54
1 0 .57
1 0 .07
1 0 .22
9 .90
9.72
9.839 .85
9 .71
9.6
9
9.7
29 .6
1
9.699 .70
9.76
11.51
9.7
1
9.1
09
.08
9.7
5
9 .03
9 .06
9 .33
9 .91
9 .94
Power
Pole
(top&
gl)
(top&
gl)
(top&
gl)
9.7
6
Bric
k R
et. W
all
(top&
gl)
TR[ ]
TF[ ]
11.41TF[ ]
(top&
gl)
9.7
5Fi
bro
Fenc
e (F
air C
ond.
)
On
Bric
k R
et. W
all
10.93TR[ ]
11.41TF[ ]
Limestone
Ret. Wall
WMeter
(top&
gl)
Closest Wire To Boundary
Pergola
10
.48
C
PEG
GONE
PEG
GONE
10.5
10.0
Galv.
Carport
Remote controlSectional door
ManualRoller door
Medium size treeRefer 13.1 &figure 3.3b
paving
paving
paving
AREA: 8.690where shown
hatched(min dim 1.5m)
AREA: 35.23where shown
hatched(min dim 1.5m)
AREA: 33.70where shown
hatched(min dim 1.5m)AREA: 33.86
where shownhatched
(min dim 1.5m)
Possible
2 Storey
Ocean Views
CHINESE ELM'Ulmas parvifolia'
DWARF MAGNOLIA (LITTLE GEM)'Magnolia grandiflora'
BLUE FESCUE'Festuca glauca'
COASTAL NATIVE ROSEMARY'Westringia fruticosa'
SIR WALTER BUFFALO GRASS
KANGAROO PAW LILAC QUEEN'Anigozanthos flavidus'
PLANT LEGENDNOTE: JUNGLE MULCH TO ALL
GARDEN BEDS TO BE 75mm THICK
VERBURNUM TINUS'Laurustinus'
REFER 11.1landscaping gardening area:(min dim 1.5m)8.690m235.22m233.70m233.86m2TOTAL: 111.47m2(min required 70m2)
REFER 11.4landscaping area: 154.08m2(min dim 1.5m)paving area: 42.80m2PERCENTAGE PAVING = 27.78%(max required 30%)
REFER 11.6Area of front setback = 81.62m2Paving + house = 36.43m2 (44.63%)Landscaping garden = 43.91m2 (53.80%)
LANDSCAPING PLAN1:100
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:SHEET: 6 of 7
© copyright
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING:
48.80%
R20/25
SITE AREA: 350m²
Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:1, 1:200, 1:500
21003
25,7
5021
,400
15,090
47,1
50
1,500 13,590
proposedaccess leg
PROPOSEDLOT 1
PROPOSEDLOT 2361m2
350m2
47.1
5
90 °0 '0 "
15.0990 °0'0 "
47.1
5
90 °0 '0 "
15.09
90 °0'0 "
10.1311.1111.03
10.9011.01
11.0511.06
10
.83
10
.53
10
.44
10.1110.19
9 .94
9.05
9.069.13
9.29 9.40
9 .80
1 0 .0 9
9 .48
9 .67
9.7
1
9 .72
9.7
5
9 .7 9
9.779.7 4
9.7
1
9.74
9.7
4
9 .73
9 .70
10
.26
9 .8 7
12.4910
.28
9.7
4
9 .85
10
.45
9 .85
9 .79
9 .80
9 .76
9 .75
9.76
9.6
91
0.1
7
9.74
9 .76
9 .87
9 .78
9 .74
9 .74
9 .75
9.9
8
9 .769.73 9
.74
9.77
10 .22
1 0 .43 1
0.5
4
1 0 .57
11.08
11.14
11.0
8
11 .0 210.94
1 0 .8 51 0 .7 8
10.64
10.5810.381 0 .4 510.39
10 .07
1 0 .22
9 .90
9.72
9.839 .85
9 .71
9.6
9
9.7
29 .6
1
9.699 .70
9.76
8.7
0
9.7
0
8.7
5
9 .11
11.51 9.7
19
.10
9.0
89
.75
9 .03
9 .06
9 .33
9 .91
9 .94
9 .91
10.0610.03
PowerPole
TreeØ 0.2mHt 5.0m
(top&
gl)
(top&
gl)
(top&
gl)
9.7
6
Bric
k R
et. W
all
Brick & Galv.On Slab
(top&
gl)
Col
orbo
nd F
ence
(Goo
d C
ond.
) On
L/St
one
Ret
. Wal
l
(top&
gl)
TR[ ]
TF[ ]
11.41TF[ ]
(top&
gl)
9.7
5Fi
bro
Fenc
e (F
air C
ond.
)O
n Br
ick
Ret
. Wal
lTF[ ]
10
.88
11.53TF[ ]
9.7
1TR[
]
Fibro & Galv.On Stumps
#9 10.93TR[ ]
12.70TF[ ]
10
.83
Fibr
o Fe
nce
(Cap
ped,
Poo
r Con
d.)
11.41TF[ ]
LimestoneRet. Wall
Ref Nail At Base Of KerbAssumed Datum 10.00 m
WMeter
(top&
gl)
Street Sign
Sewer M/SApprox. 21.12m(12.86) >>>>>>
.
1:200cJ/N: DATE: DRAWN:SCALE:
Licensed Surveyors
87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998
Email : [email protected] Website: www.cottage.com.au
Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.
Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.
Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.
Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
SEC DomePower PolePhone Pits
LEG
END
T C
TP10.00TWTRTF
[[[[
10.0010.0010.00
]]]]
Top Pillar/PostTop WallTop RetainingTop Fence
W Water Conn.
to be repegged and exact offsets provided to yourdesigner/architect before any plans are producedand before any work is started on site.
Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and wallswhich may not be on the correct alignment. Anydesign that involves additions to any structuresshown or portion of structures remaining afterany demolition has taken place requires boundaries
DISCLAIMER:
High StreetBitumen
Mountable
Nil
OLDAREA
0 2 4 6 8
W
S
E
N
SOIL DESCRIPTIONSandRefer to Survey
490771 22 Jan 21 J.Genovese
Builder : Coast Homes WA Pty LtdCLIENT : Roebuck and ParkerLOT 258 #11 High Street, Sorrento
Plan2820
R . O . W(Bitumen)
NOTE/BEWARE:ADVISE TRADESO/Head power lines
Closest Wire To Boundary
NilConc.Conc.
Conc.Nil
Mountable
Nil
Mountable
MountableNil
NilConc.
Brick & Galv.Garage
Brick Paved
2-Storey Weatherboard/Brick & Galv. On Slab
Brick &Galv.
Pergola
Firs
t Flo
or
Gro
und
Floo
r
Balcony
Weatherboard& Galv.
Approx. F/LAt Porch
10.57
Approx. F/LAt Porch
9.46
Galv.Pergola
Concrete
Brick PavedCrossover Brick Paved
Crossover
10
.48
Sewer JunctionIn: 3.7 Up: 1.2Inv: 6.9 Depth: 1.3NOTE: UP
C
PEGGONE
PEGGONE
PEGGONE
PEGGONE
10.09.
5
10.5 11.0
10.0
10.5
10.0
11.0
Galv.Carport
10.5
6.10
0
NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.
Gas/ElecComb m/box PCD
5,00
018
,755
1,99
5
5,00
018
,755
1,99
5
1,900 2,190 10,000 1,400
2,000
1,400
5,00
0
5,50
0
1,500 30
1,530
1,00
0
4,500
proposed location ofnew power dome
distribution boxby owner
strip drainconnectedto soakwell proposed panel &
post retaining wallTOW @ 10.200
colorbond boundaryfence & plinths by
owner after handover
paved crossoverby owner after
handover tocouncil specs.
proposed panel &post retaining wall
TOW @ 10.500
1600 x 600concrete a/cplinth @ -1c
1200Ø x 1200Dsoakwell
1200Ø x 1500Dsoakwell
Possible2 Storey
Ocean Views
PROPOSEDRESIDENCEFFL AT 9.90upper floor areashown hatched
GARAGEFFL 9.814-1c conc
hwu
ALFRESCOpaved -1cRL 9.814
tap
tap
PORCpaved -1cRL 9.814
pavedd'way
STRATA PLAN1:500
SITE PLAN - PROPOSED1:200
PROPOSED RESIDENCE TO BE ERECTED ON:
FOR:
AMENDMENTS:
CONTRACT NO:SCALE:DSN:DATE:DRN:SHEET: 7 of 7
© copyright
LOCAL AUTHORITY: City of Joondalup
SALES CONSULTANT:
SITE COVER:
ZONING:
48.80%
R20/25
SITE AREA: 350m²
Lot 258 (#11) High StreetSorrento
Mr L.Roebuck & Mrs C.Parker
A3 SHEET14/7/21 GM various amendments 09/08/21 CW Planning amendment
JR12/08/2021
1:200
21003
47.1
5
90 °0 '0 "
15.0990 °0'0 "
47.1
5
90 °0 '0 "
15.09
90 °0'0 "
10.1311.1111.03
10.9011.01
11.0511.06
10
.83
10
.53
10
.44
10.1110.19
9 .94
9.05
9.069.13
9.29 9.40
9 .80
1 0 .0 9
9 .48
9 .67
9.7
1
9 .72
9.7
5
9 .7 9
9.779.7 4
9.7
1
9.74
9.7
4
9 .73
9 .70
10
.26
9 .8 7
12.4910
.28
9.7
4
9 .85
10
.45
9 .85
9 .79
9 .80
9 .76
9 .75
9.76
9.6
91
0.1
7
9.74
9 .76
9 .87
9 .78
9 .74
9 .74
9 .75
9.9
8
9 .769.73 9
.74
9.77
10 .22
1 0 .43 1
0.5
4
1 0 .57
11.08
11.14
11.0
8
11 .0 210.94
1 0 .8 51 0 .7 8
10.64
10.5810.381 0 .4 510.39
10 .07
1 0 .22
9 .90
9.72
9.839 .85
9 .71
9.6
9
9.7
29 .6
1
9.699 .70
9.76
8.7
0
9.7
0
8.7
5
9 .11
11.51 9.7
19
.10
9.0
89
.75
9 .03
9 .06
9 .33
9 .91
9 .94
9 .91
10.0610.03
PowerPole
TreeØ 0.3mHt 4.0m
TreeØ 0.3mHt 4.0m
TreeØ 0.2mHt 4.0m
BushØ 0.2mHt 3.0m
TreeØ 0.2mHt 5.0m
Brick & TileOn Slab
#11
Approx. F/L AtFront Door On
Brick 9.80
Approx. F/L AtRear Door On
Brick 9.78
(top&
gl)
(top&
gl)
(top&
gl)
9.7
6
Bric
k R
et. W
all
Brick & Galv.On Slab
(top&
gl)
Col
orbo
nd F
ence
(Goo
d C
ond.
) On
L/St
one
Ret
. Wal
l
(top&
gl)
TR[ ]
TF[ ]
BrickWall
11.41TF[ ]
(top&
gl)
9.7
5Fi
bro
Fenc
e (F
air C
ond.
)O
n Br
ick
Ret
. Wal
l
Tap
TF[ ]
10
.88
11.53TF[ ]
9.7
1TR[
]
10
.39
TF[]
Colorbond Fence(Good Cond.) OnFibro Ret. Wall
Fibro & Galv.On Stumps
#9 10.93TR[ ]
12.70TF[ ]
10
.83
Fibr
o Fe
nce
(Cap
ped,
Poo
r Con
d.)
11.41TF[ ]
LimestoneRet. Wall
Ref Nail At Base Of KerbAssumed Datum 10.00 m
WMeter
(top&
gl)
Bric
k R
et. W
all
Street Sign
Sewer M/SApprox. 21.12m(12.86) >>>>>>
Meter Box(Elec.)M
Meter Box(Gas)
G
.
1:200cJ/N: DATE: DRAWN:SCALE:
Licensed Surveyors
87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998
Email : [email protected] Website: www.cottage.com.au
Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.
Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.
Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.
Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
DISCLAIMER:
SEC DomePower PolePhone Pits
LEG
END
T C
TP10.00TWTRTF
[[[[
10.0010.0010.00
]]]]
Top Pillar/PostTop WallTop RetainingTop Fence
W Water Conn.
to be repegged and exact offsets provided to yourdesigner/architect before any plans are producedand before any work is started on site.
Due to lack of survey marks/pegs, all building offsetdimensions & features are approximate only andpositioned from existing pegs/fences and wallswhich may not be on the correct alignment. Anydesign that involves additions to any structuresshown or portion of structures remaining afterany demolition has taken place requires boundaries
DISCLAIMER:
High StreetBitumen
Mountable
Nil
OLDAREA
0 2 4 6 8
W
S
E
N
SOIL DESCRIPTIONSandRefer to Survey
490771 22 Jan 21 J.Genovese
Builder : Coast Homes WA Pty LtdCLIENT : Roebuck and ParkerLOT 258 #11 High Street, Sorrento
Plan2820
R . O . W(Bitumen)
NOTE/BEWARE:ADVISE TRADESO/Head power lines
Closest Wire To Boundary
Cons
umer
Ove
rhea
d
Powe
r Cab
le
NilConc.Conc.
Conc.Nil
Grass
Grass
Grass
Concrete
Concrete
Concrete
Sand
Concrete StepsFibroShed
SandGate
Mountable
Nil
Mountable
MountableNil
NilConc.
Brick & Galv.Garage
Brick Paved
2-Storey Weatherboard/Brick & Galv. On Slab
Brick &Galv.
Pergola
Firs
t Flo
or
Gro
und
Floo
r
Balcony
Weatherboard& Galv.
Approx. F/LAt Porch
10.57
Approx. F/LAt Porch
9.46
Galv.Pergola
Concrete
Concrete Slabs
Con
cret
e
Car
port
UM
RO
n C
oncr
ete
ConcreteDriveway
ConcreteCrossoverBrick Paved
Crossover Brick PavedCrossover
10
.48
Sewer JunctionIn: 3.7 Up: 1.2Inv: 6.9 Depth: 1.3NOTE: UP
C
BrickL/Box
PEGGONE
PEGGONE
PEGGONE
PEGGONE
10.09.
5
10.5 11.0
10.0
10.5
10.0
11.0
Galv.Carport
10.5
BrickWall
6.10
0
NOTE:Approx. Sewer Clearance Line(This line is NOT an easement)Setbacks MUST be confirmedby Water Corp. before anydesign work is undertaken.This line is NOT definitive.
existing crossoverto be removed
(kerb reinstated)
existing treesto be removedexisting treesto be removedexisting treesto be removed
Possible2 Storey
Ocean Views
existing treesto be removed
SITE PLAN - EXISTING1:200