    Technical Description

    General Information

    CCIs Multi-Carrier Cell Extender System breaks

    with traditional integration concepts and sets a

    new direction with our seamlessly integrated di-

    rect mounting systems. Derived from our SCPA

    product line, our MCPA hanging cabinets and en-

    closures require no dedicated pad space, saving

    valuable deployment time and cost. The system

    employs a new highly efficient MCPA design that isan integral part of CCIs complete turn-key MCPA

    system. High power density of the MPCA module

    and power plant create a powerful compact pack-

    age. The MCPA system supports multiple simulta-

    neous formats such as GSM/EDGE, CDMA1X/DO,

    and UMTS. Multiple radios are combined on high

    capacity sites to reduce the required number of

    feeders without impacting coverage. CCIs MCPA

    is a key element in upgrading or cositing existing

    (growth) or new base stations. Optional N+1 re-

    dundancy configurations and integrated VSWR

    monitoring with I/P addressability are available.

    General Info 1

    Technical Description 1

    Electrical Specifications 2

    Mechanical Specifications 3

    Module Locations 5

    Block Diagrams & ModuleConfigurations

    14 -

    Outdoor Cabinet Outline 21

    Ordering Information 21

    Indoor Rack Outline 22

    Secondary Modules 10 -

    MCPA Specifications 4

    Duplexer/Attenuator Tech-nical Description & Specs.

    6-9

    Contents

    CCIs MCPA employs a high efficiency Feed Forward design that works with multi-

    ple modulation formats simultaneously. Multi-Loop architecture reduces the num-

    ber of components and increases reliability. An internal microprocessor circuit

    controls all functions, maintains long term (thermal) and short term (distortion)

    functions, and generates status and alarms. An auto-reboot feature will automati-

    cally restart the MCPA module in case of power interruptions. Fans are alarmedand hot swappable, requiring only common tools to change. Module efficiency is

    greater than 16% due to an advanced Doherty type architecture which also reduces

    current consumption during low traffic periods. Intermodulation distortion is ex-

    tremely low, better than 65 dBc typical, due to a custom pre-linearizer circuit. Dry

    contact alarms are also provided for simple interface to existing base station alarm

    reporting circuits.

    Model CE-1819-200MC

    CCI Confidential

    Mult i-Carr ier Cell Extender System

    With PCS 200 Watt MCPA

    Conf igu rat ion and Speci f ications

    CDMA PCS Edition

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    2/22

    2

    Multi-Carrier Cell Extender System Level Specifications

    Description Typical Specifications

    Electrical Forward Link (Downlink) Reverse Link (Uplink)

    Frequency range of operation 1930 -1990 MHz 1850 - 1910 MHz

    Composite Output Power (per Sector) 200 Watts

    System Gain

    12 dB Nominal, adjustable from10 dB to 24 dB - AISG PCS TwinTMA

    12 dB - Standard PCS Full BandTwin TMA,14 dB - Standard PCS Twin TMA(with High Gain (-HG) Option)

    Gain Variation 0.5 dB Max. 0.5 dB Max.

    Output Third Order IM3 @ 1.98 MHz Offset -55 dBc/30 kHz N/A

    Harmonics and Out of Band Spurious -13 dBm Max. N/A

    System Group Delay 180 nSec Max.

    Input/Output VSWR 1.5:1 Max. 1.5:1 Max.

    Up-Link-Down-Link Isolation 90 dB

    Uplink Noise Figure1.6 dB Midband; 2.0 dB Band Ed

    (AISG DTMA) - other DTMAs Av

    Power Supply Voltage

    Indoor: +27 VDC PDU (+26 to +28 VDC)

    Outdoor:220 VAC (AC PPS)2-4 Hours Battery Backup (Optio

    Power Consumption 1.5 KW Max. per Sector @ 27 VDC (46A DC @ +27 VDC/Amplifier)

    Adjustable to 13 dB in 1 dB steps

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    3/22

    3

    Multi-Carrier Cell Extender System Level Specifications (Cont.)

    Description Typical Specifications

    Mechanical

    RF Connectors

    Input from BTS: N-Female

    Output to Hardline: 7/116 DIN-Female

    Tower Top Amplifier: 7/16 DIN-Female

    AC PPS Input Connectors 4 Position (1/4-20 Stud, 7/16 Nut) terminal block

    AC PPS Battery Backup Connectors 3 Position (#8 Screw) terminal block

    DC PDU Input Connectors One pair of terminals with 3/8-16 threaded studs with 5/8 nuts

    Dimensions

    TTA - 14.3 H x 8.4 W x 3.2 D (AISG or Std. DTMA with Brackets)

    Outdoor Cabinet - 71.1 H x 22.5 W x 25 D (with Battery Backup Copartment)

    Outdoor Cabinet - 47.5 H x 22.5 W x 25 D (without Battery BackupCompartment)

    40U Indoor Rack - 78.75 H x 24 W x 24 D (without Plinth)

    Weight

    TTA

    Outdoor Cabinet *

    1 Sector Single - 300 Lbs. Max.

    2 Sector Single - 350 Lbs. Max.

    3 Sector Dual - 850 Lbs. Max

    Indoor Rack

    1 Sector Single - 225 Lbs. Max.

    2 Sector Dual - 325 Lbs. Max

    3 Sector Dual - 575 Lbs. Max

    Environmental

    Enclosure

    TTA - IP65 (Unit Body), IP67 (Connector)

    Outdoor Cabinet NEMA 3R

    Indoor 19 Rack

    Operating Temperature Range -25 C to +50 C

    14.3 Lbs. Max.;Lightweight - 12.6 Lbs. Max.

    1 Sector Dual - 350 Lbs. Max

    2 Sector Dual - 450 Lbs. Max

    3 Sector Single - 400 Lbs. Max.

    1 Sector Dual - 250 Lbs. Max

    2 Sector Single - 250 Lbs. Max.

    3 Sector Single - 300 Lbs. Max.

    * Outdoor Cabinet Weights do not include Backup Batteries, but do include Backup Battery Compartment

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    4/22

    4

    200 Watt Multi-Carrier Power Amplifier Module (MCPA)

    Description Typical Specifications

    Frequency range of operation 1930-1990 MHz

    Operating Bandwidth 40 to 60 MHz

    Output Power 200 Watts

    Gain 63 dB

    Gain variation over temperature 0.75 dB

    Passband flatness 1.0 dB

    Module Efficiency 16.5%

    Module Current Draw 46 Amps

    Operating Voltage 26 to 28 VDC

    Out of Band Spurious Meets FCC

    Input return loss (VSWR) > 15 dB (1.4:1)

    Output Return Loss (VSWR) > 15 dB (1.4:1)

    Dimensions 3.9 x 13.4 x 17.5

    Weight 30 Pounds

    Operating Temperature Range -25 C to +65 C

    Operating Relative Humidity 0% to 99%

    Operating Altitude Up to 13,000 FT

    * Note: with 8 GSM and 1 UMTS carriers

    Features & Benefits

    Low IMD Products - 65 dBc Hot Swappable Fans

    Works with all Modulations

    High Efficiency

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    5/22

    5

    Module locations

    AC Rectifier / PDU

    with N+1 Redundancy

    Optional PDU for TMAs with

    Antenna VSWR Monitoring

    200W Feed Forward

    MCPA Modules

    4 modules max

    per sub-rack

    Combiner/Duplexer

    Modules

    Auto sensing

    Bypass module

    SECTOR 1

    (Inputs)SECTOR 2

    (Inputs)SECTOR 3

    (Inputs)

    SECTOR 1

    (Outputs)

    SECTOR 2

    (Outputs)SECTOR 3

    (Outputs)

    AC JUNCTIONBOX

    ACTO

    PPS(3-W

    ire)

    TOBATT.PO

    S.(1Wir

    e)

    TOBATT.

    NEG

    .(1Wire

    )

    TX4

    TX1/RXATX2/RXBTX1/RXATX2/RXBTX1/RXATX2/RXB

    TX3TX3TX4TX3TX4

    ANT AANTBANTAANTBANTAANT B

    TX5TX6TX5TX6TX5TX6

    INPUT01

    OUTPUT01

    DATA

    ATTEN01

    PWR/ALM

    INPUT02

    OUTPUT02

    ATTEN 02

    DUALATTENUATOR

    MODULE

    LOCREM

    1 dB

    2 dB4 dB

    8 dB16dB

    TOTALATTEN42 dB

    +

    LOCREM

    1 dB2 dB4 dB

    8 dB

    16dB

    TOTALATTEN42 dB

    +

    TX

    TX

    TX

    /

    RX

    TX

    /

    RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXERMODULE

    TX

    TX

    TX

    /

    RX

    TX

    /

    RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXERMODULE

    INPUT01

    OUTPUT01

    DATA

    ATTEN 01

    PWR/ALM

    INPUT02

    OUTPUT 02

    ATTEN02

    DUALATTENUATO RMODULE

    LOCREM

    1dB

    2dB4dB

    8dB16 dB

    TOTALATTEN42 dB

    +

    LOCREM

    1dB

    2dB4dB

    8dB16 dB

    TOTALATTEN42 dB

    +

    TX

    TX

    TX

    /

    RX

    TX

    /

    RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXER MODULE

    TX

    TX

    TX

    /

    RX

    TX

    /

    RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXER MODULE

    MCPA BYPASS MODULE

    AMP 1 AMP 4AMP 3AMP 2

    MODEL # BYP-MCPB-200

    DC INPWR BP3BP4PWR BP1BP2

    Alarms

    RESET/STROBE

    Power Distribution Unit

    +-

    654321

    DC INPUT

    (EITHER POLARITY)

    PSU

    ON

    1

    0OFF

    10

    ON

    1

    0

    OFF

    10

    BATT

    ON

    MODFA

    IL

    ACPWRON

    1 432

    5

    606

    606060

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    6/22

    6

    Input /Output Duplexer Module

    CCIs Input/Output (or Transmit) Duplexer is a

    high Q design optimized for low insertion loss with

    high power handling Operating in conjunction withthe Cell Extenders PA and LNA, the duplexer pro-

    vides a high rejection high performance filter to

    separate transmit and receive signals for the Cell

    Extender System. No additional system filtering is

    required.

    This unit is in full compliance with FCC emission re-

    quirements with particular attention to design to

    minimizing passive intermodulation products. It is

    modular by design in order to accommodate alter-

    nate site and radio count requirements.

    CommonSpecificationsImpedance 50 Ohms

    DC Pass Current 3 Amps

    Temperature Range -20 to +70 deg C.

    Weight 9.75 Pounds MaximumEnvironmental Protection Indoor

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    7/22

    7

    Input / Output Duplexer Module

    Description Typical Specifications

    Input Tx Path

    Passband 1930 MHz -1990 MHz

    Insertion Loss 0.5 dB

    Amplitude Ripple 0.4 dB Max / 3.84 MHz Band

    Group Delay 40 nSec Max / 3.84 MHz Band

    Phase Ripple 75 Deg Max / 3.84 MHz Band

    Return Loss 15 dB Minimum

    Power Handling 100 W Average, 1KWatt Peak

    Rx Band Rejection 60 dB Minimum (1850 MHz-1910 MHz)

    Output Tx PathPassband 1930 MHz -1990 MHz

    Insertion Loss 0.5 dB

    Amplitude Ripple 0.3 dB Max / 3.84 MHz Band

    Group Delay 30 nSec Max / 3.84 MHz Band

    Phase Ripple 75 Deg Max / 3.84 MHz Band

    Return Loss 15 dB Minimum

    Power Handling 200 W Average, 5KWatt Peak

    Rx Band Rejection 86 dB Minimum (1850-1910 MHz)IMD within Rx Band -150 dBc min (2 x 100 Watt tones)

    Passband 1850 MHz -1910 MHz

    Insertion Loss 0.5 dB

    Amplitude Ripple 0.25 dB Max / 3.84 MHz Band

    Group Delay 25 nSec Max / 3.84 MHz Band

    Phase Ripple 60 Deg Max / 3.84 MHz Band

    Return Loss 15 dB MinimumTx Band Rejection 60 dB Minimum (1930 MHz-1990 MHz)

    Rx Path

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    8/22

    8

    Dual Attenuator Module

    CCIs Dual Attenuator Module is used to set the correct

    system gain for one or two channels (active Antennas)

    per sector as required. The Dual Attenuator Module isavailable in either the PCS or Cellular frequency bands.

    Overall system gain is adjustable with this module. CCIs

    Dual Attenuator Module provides two pairs of Input (01

    and 02) and Output (01 and 02) ports with attenuation

    values ranging from 42 dB (when no additional internal

    attenuation is set) to 73 dB (when all attenuation is set

    to ON) in 1 dB increments. Attenuator value can be

    set for either Local or Remote operation. Local opera-

    tion of each attenuator is performed by setting the LOC/

    REM switch on the DIP Switch to the LOC position, andthen selecting the value of attenuation required at the

    DIP switch. Remote operation is performed through

    input to the DATA (RJ45) port via Ethernet connection

    to the Dual Attenuator Module. The LOC/REM and at-

    tenuation switches can be Hot Switched (i.e. switched

    while power is applied). DC Connection is at the rear of

    the module via a header which connects to the DCA

    chassis (tray) and provides power for fan operation, re-

    mote attenuator control, alarm circuitry and LED status

    indicators. Dry contact alarms are provided via the

    DATA RJ45 connector for simple interface to CCIs

    Alarm Board typically located below the Bypass Module

    at the bottom of the Cell Extender Outdoor Cabinet, or

    behind the DCA Tray near the top of the Cell Extender

    Indoor Rack.

    Fan

    Connector

    DC Input(-)

    (+)

    Front View Rear View

    Dual Attenuator Module Block Diagram

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    9/22

    9

    Dual Attenuator Module

    Description Typical Specifications

    Electrical

    Operating Frequency Band 1930 MHz -1990 MHz

    Nominal Input/Output Impedance 50 Ohm

    Attenuation at 0 dB Setting 42 dB 1.5 dB

    Normalized Attenuation Range 0 - 31 dB in 1 dB steps

    Port Return Loss 15 dB Minimum

    Power Handling 100W Average, 1 KW Peak

    DC Supply Voltage 30 VDC Max., 22-30 VDC

    DC Supply Current 650 mA Max.

    Indicators

    Green Power Supply OK

    Red Fan Alarm

    Mechanical

    Number of Inputs/Outputs 2 Inputs / 2 Outputs

    RF Connectors

    2 x SMA-Female - OUTPUT 01 &OUTPUT 02 (Tx Out to MCPA)

    2 x N-Female - INPUT 01 &INPUT 02 (Tx In to I/O Duplexer)

    DC Power Connector Type

    2 pin Tyco header Type MTA-100(0.025 Sq. pins on 0.100 Centers)

    Fan Connector Type3 pin Tyco header Type MTA-100(0.025 Sq. pins on 0.100 Centers)

    Remote Interface/Alarm (Data) Connector RJ45 (Alarm & RS485 Signal Lines)

    Attenuator Control 6 position DIP Switch

    Dimensions 10.5 H x 1.75 W x 5.5 D

    Weight 2.5 Lbs. Max

    Environmental

    Operating Temperature -20 to +70 deg C.

    Environmental Protection Indoor

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    10/22

    10

    Secondary Cell Extender Modules

    Duplexer Combiner Attenuator ModuleP/N DCA-1819-XX

    CCIs Duplexer-Combiner-Attenuator (DCA) module utilizes the latest filter

    technology to achieve full compliance with FCC emission requirements

    with particular attention to minimizing passive intermodulation products.

    A block diagram of the module is provided (see figure 1). The Duplexer-

    Combiner-Attenuator (DCA) module is modular by design in order to ac-

    commodate alternate site and radio count requirements. The DCA is able

    to operate with all common modulation types, CDMA, W-CDMA, UMTS,

    GSM and EDGE and most likely with other types of modulation needed for

    future formats

    Bypass ModuleP/N BYP-0821-200-X-Y

    The optional bypass module utilizes the latest high power switching technology to

    achieve full bypass functionality of up to six MCPA modules in the event of an

    MCPA failure or power outage. The BPM is rated for the full peak output power of

    the MCPAs and is able to operate with all common modulation types, CDMA, W-

    CDMA, UMTS, GSM and EDGE. Six MCPA Modules are only utilized when a 3-Sector

    Dual MCPA is requested, otherwise three or four MCPAs are typically utilized.

    Note: X = the number of RF Switches utilized, and Y=O for Outdoor, or I for

    Indoor configuration. Also note: RF Switches for the Indoor configuration are ro-

    tated 180 from the Outdoor configuration, due to the point of cable entry.

    These additional modules each have a function within the cell extender for a

    specific configuration, and may or may not be required for an application.

    Additional detailed specifications are available

    1

    2

    3

    4

    1

    2

    3

    4

    1

    2

    3

    4

    1

    2

    3

    4

    1

    2

    3

    4

    1

    2

    3

    4

    INPUT 01

    OUTPUT

    01

    DATA

    ATTEN 01

    PWR/ALM

    INPUT 02

    OUTPUT 02

    ATTEN 02

    DUAL ATTENUATOR

    MODULE

    LOCREM

    1 dB2 dB

    4 dB

    8 dB

    16 dB

    TOTALATTEN

    42 dB

    +

    LOCREM

    1 dB2dB4dB

    8 dB16 dB

    TOTALATTEN

    42 dB

    +

    TX

    TX

    TX

    /

    RX

    TX/

    RX

    FROMMCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXER MODULE

    TX

    TX

    TX

    /

    RX

    TX/

    RX

    FROMMCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMIT DUPLEXER MODULE

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    11/22

    11

    N+1 Redundancy Switch Module - MCPA-RDD

    CCIs N+1 Redundancy Switch (a matrixed switch array) provides a means of redi-

    recting (re-routing) the RF signals from the input and output of a failed MCPA Mod-ule to the input and output of a Spare MCPA Module. This allows the amplified

    signal to continue to be available in the event of an MCPA failure. When a failure

    of one of the MCPAs occurs, the operation of CCIs CDMA Cell Extender System is

    transparent to the BTS as long as the remaining MCPAs continue to operate. Indi-

    cation of the Alarm status will be transmitted to the BTS thereby allowing the Car-

    rier (Provider) to request repair/replacement of the failed MCPA. DC Input connec-

    tion is made at the rear of the N+1 Redundancy Switch. The N+1 Redundancy re-

    quires DC input in order to provide power for alarm circuitry, LED status indicators

    and to power the multiple RF Switches that switch the RF signal path in the

    event of an MCPA failure. Similarly, dry contact alarms are also provided at therear of the N+1 Redundancy Switch for simple interface to CCIs Alarm Board typi-

    cally located below the Bypass Module at the bottom of the Cell Extender Outdoor

    Cabinet, or behind the DCA Tray near the top of the Cell Extender Indoor Rack.

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    12/22

    12

    Converts 220VAC into 28VDC for MCPA and other

    modules. Consists of two primary and a third redun-

    dant (N+1) plug-in. The entire Cell Extender is pow-

    ered by the two primary modules, the third serves as

    a backup in case of loss of either of the two primary

    units. The PPS also includes provisions for optionalbattery back-up solutions and is available in two ver-

    sions in order to accommodate the various options

    available. This unit is available with or without bat-

    tery charging circuitry

    AC Power System with RectifiersP/N PPS-200A-28V-PPS

    The optional VPDU collects VSWR data and provides remote highly accurate

    VSWR alarming of the antenna system. The system consists of VSWR meas-

    uring Bias-Ts and the PDU unit, located at the BTS.

    VSWR Monitor / TMA Power Distribution Unit (VPDU)

    Bias-T / VSWRMonitor Unit

    (BTV)

    MODEL#REC-100A-28V

    SN:

    MODEL#REC-100A-28V

    SN:

    MODEL#REC-100A-28V

    SN:

    BATT

    ON

    MODFAIL

    ACPWR

    ON

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    13/22

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    14/22

    14

    System Block Diagram - 3 Sector Single MCPA with Bypass

    O

    T

    M

    A

    TX/RX

    MAINANTENNA

    T

    M

    A

    RX

    DIVERSITYANTENNA

    S

    E

    C

    T

    O

    R

    1

    BT

    S

    TX + RXMAIN

    RX

    DIVERSITY

    TX + RX

    MAIN

    RXDIVERSITY

    TX + RXMAIN

    RX

    DIVERSITY

    S

    E

    C

    T

    O

    R

    1

    SEC

    T

    O

    R

    2

    S

    E

    C

    T

    O

    R

    3

    C

    1

    2

    C1

    2

    BYPASS

    MCPA

    T

    M

    A

    TX/RX

    MAIN

    ANTENNA

    T

    M

    A

    RX

    DIVERSITYANTENNA

    C

    1

    2

    C1

    2

    BYPASS

    MCPA

    T

    MA

    TX/RXMAIN

    ANTENNA

    T

    MA

    RX

    DIVERSITYANTENNA

    C

    1

    2

    C1

    2

    BYPASS

    MCPA

    BIAS-T

    BIAS-T

    BIAS-T

    BIAS-T

    BIAS-T

    BIAS-T

    PDU to Power Bias-Ts

    INPUTDUPLEXER

    OUTPUT

    DUPLEXER

    RX RX

    HIGH POWER

    ATTENUATOR

    DCBYPASS

    TX TX

    INPUTDUPLEXER

    OUTPUTDUPLEXER

    RX RX

    HIGH POWERATTENUATOR

    DC

    BYPASS

    TX TX

    INPUTDUPLEXER

    OUTPUTDUPLEXER

    RX RX

    HIGH POWER

    ATTENUATOR

    DCBYPASS

    TX TX

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    15/22

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    16/22

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    17/22

    17

    System Block Diagram - N+1 Redundancy

    S

    E

    C

    T

    O

    R

    2

    S

    E

    C

    T

    O

    R

    3

    T

    M

    A

    TX/RX

    MAIN

    ANTENNA

    T

    M

    A

    RX

    DIVERSITY

    ANTENNA

    S

    EC

    T

    O

    R

    1

    B

    T

    S

    TX + RX

    MAIN

    RX

    DIVERSITY

    TX + RX

    MAIN

    RX

    DIVERSITY

    TX + RXMAIN

    RX

    DIVERSITY

    S

    E

    C

    T

    O

    R

    1

    SE

    C

    T

    O

    R

    2S

    E

    C

    TO

    R

    3

    C

    1

    2

    C1

    2

    MCPA

    T

    M

    A

    TX/RX

    MAINANTENNA

    T

    M

    A

    RX

    DIVERSITYANTENNA

    C

    1

    2

    C1

    2

    MCPA

    T

    M

    A

    TX/RX

    MAIN

    ANTENNA

    T

    M

    A

    RX

    DIVERSITY

    ANTENNA

    C

    1

    2

    C1

    2

    MCPA

    C

    1

    2

    3

    4

    C

    1

    2

    3

    4

    SPARE

    MCPA

    N+1 REDUNDANCY

    BIAS-T

    BIAS-T

    BIAS-T

    BIAS-T

    INPUTDUPLEXER

    OUTPUTDUPLEXER

    RX RX

    HIGH POWERATTENUATOR

    DCBYPASS

    TX TX

    INPUTDUPLEXER

    OUTPUTDUPLEXER

    RX RX

    HIGH POWERATTENUATOR

    DC

    BYPASS

    TX TX

    BIAS-T

    BIAS-T

    PDU to Power Bias-Ts

    INPUTDUPLEXER

    OUTPUTDUPLEXER

    RX RX

    HIGH POWER

    ATTENUATOR

    DCBYPASS

    TX TX

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    18/22

    18

    3 Sector with N+1 Redundancy - Module Configuration

    SECTOR 1

    (Inputs)SECTOR 2

    (Inputs)SECTOR 3

    (Inputs)

    SECTOR 1

    (Outputs)

    SECTOR 2

    (Outputs)SECTOR 3

    (Outputs)

    AC JUNCTION BOX

    ACTO

    PPS(3-W

    ire)

    TOBA

    TT.PO

    S.(1W

    ire)

    TOBATT.

    NEG.(

    1Wire)

    TX4

    TX1/RXATX2/RXBTX1/RXATX2/RXBTX1/RXATX2/RXB

    TX3TX3TX4TX3TX4

    ANT AANT BANT AANT BANT AANT B

    TX5TX6TX5TX6TX5TX6

    INPUT 01

    OUTPUT

    01

    DATA

    ATTEN01

    PWR/ALM

    INPUT02

    OUTPUT02

    ATTEN 02

    DUAL ATTENUATOR

    MODULE

    LOCREM

    1dB2dB4dB

    8dB16dB

    TOTALATTEN42dB

    +

    LOCREM

    1dB2dB4dB

    8dB16dB

    TOTALATTEN42dB

    +

    TX

    TX

    TX/RX

    TX/RX

    FROMMCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXER MODULE

    INPUT01

    OUTPUT

    01

    DATA

    ATTEN01

    PWR/ALM

    INPUT 02

    OUTPUT02

    ATTEN 02

    DUAL ATTENUATOR

    MODULE

    LOCREM

    1dB2dB4dB

    8dB16dB

    TOTALATTEN42 dB

    +

    LOCREM

    1dB2dB4dB

    8dB16dB

    TOTALATTEN42 dB

    +

    TX

    TX

    TX/RX

    TX/RX

    FROMMCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXER MODULE

    REDUNDANCY SW

    A

    C

    B

    SEC

    OUT SWSEC-A/IN OUT SW SEC-B/IN OUT SW SEC-C/IN OUT SWSPARE/IN

    IN SW SEC-A/OUT IN SW SEC-B/OUT IN SW SEC-C/OUT IN SWSPARE/OUT

    OUT SW SEC-A/OUT OUT SW SEC-B/OUT OUT SW SEC-C/OUT

    IN SW SEC-C/ININSW SEC-B/ININ SW SEC-A/IN

    INPUT 01

    OUTPUT01

    DATA

    ATTEN

    01

    PWR/ALM

    INPUT02

    OUTPUT 02

    ATTEN 02

    DUAL ATTENUATOR

    MODULE

    LOCREM

    1dB2dB4dB

    8dB16dB

    TOTALATTEN42dB

    +

    LOCREM

    1dB

    2dB4dB

    8dB16 dB

    TOTALATTEN42dB

    +

    TX

    TX

    TX/RX

    TX/RX

    FROMMCPA

    TOATTEN

    BTS

    ANT

    TRANSMITDUPLEXER MODULE

    Alarms

    RESET/STROBE

    Power Distribution Unit

    +-

    654321

    DC INPUT

    (EITHER POLARITY)

    PSU

    ON1

    0

    OFF

    10

    ON1

    0

    OFF

    10

    BATT

    ON

    MOD

    FAIL

    ACPW

    RON

    1 432

    5

    606

    606060

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    19/22

    19

    System Block Diagram - 3 Sector Dual MCPA with Bypass

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    20/22

    20

    2 Sector Dual MCPA with Bypass Module Configuration*

    * Note:

    1. Only a 2-Sector Dual MCPA w/Bypass (as shown) can be achieved in a single Outdoor Cabinet (due to space limita-

    tions).

    2. The 3-Sector Dual MCPA w/Bypass can only be achieved in either a 2nd Outdoor Cabinet or an optional taller Cabinhowever, a second AC PPS or DC PDU will be required, as they can only supply DC Power to a maximum of four

    MCPA Modules each.

    3. The 3-Sector Dual MCPA w/Bypass can be achieved in the Indoor Rack , however, a second AC PPS or DC PDU will

    be required, as they can only supply DC Power to a maximum of four MCPA Modules each.

    SECTOR1(Inputs)

    SECTOR 2(Inputs)

    SECTOR 3(Inputs)

    SECTOR 1

    (Outputs)

    SECTOR2(Outputs)

    SECTOR3(Outputs)

    AC JUNCTION BOX

    ACTO

    PPS(3

    -Wire)

    TOBATT

    .POS.

    (1Wire)

    TOBA

    TT.NE

    G.(1W

    ire)

    TX4

    TX1/RXATX2/RXBTX1/RXATX2/RXBTX1/RXATX2/RXB

    TX3TX3TX4TX3TX4

    ANT AANT BANT AANT BANT AANT B

    TX5TX6TX5TX6TX5TX6

    INPUT 01

    OUTPUT

    01

    DATA

    ATTEN01

    PWR/ALM

    INPUT 02

    OUTPUT 02

    ATTEN 02

    DUAL ATTENUATORMODULE

    LOCREM

    1 dB2 dB4 dB

    8 dB16 dB

    TOTALATTEN42dB

    +

    LOCREM

    1dB2 dB4 dB8 dB16dB

    TOTALATTEN42dB

    +

    TX

    TX

    TX

    /

    RX

    TX

    /RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXERMODULE

    TX

    TX

    TX

    /

    RX

    TX

    /RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXERMODULE

    MCPA BYPASS MODULE

    AMP 1 AMP 4AMP 3AMP 2

    MODEL # BYP-MCPB-200

    DC INPWR BP3 BP4PWR BP1BP2

    Alarms

    RESET/STROBE

    Power Distribution Unit

    +-

    654321

    DC INPUT

    (EITHER POLARITY)

    PSU

    ON1

    0

    OFF

    10

    ON1

    0OFF

    10

    BATT

    ON

    MODFAIL

    ACPW

    RON

    1 432

    5

    606

    606060

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    OUTIN

    1900 MHz MCPA

    ACT

    ALMON

    OFF

    INPUT 01

    OUTPUT

    01

    DATA

    ATTEN 01

    PWR/ALM

    INPUT 02

    OUTPUT 02

    ATTEN 02

    DUAL ATTENUATORMODULE

    LOCREM

    1 dB2 dB4 dB8 dB16 dB

    TOTALATTEN42dB

    +

    LOCREM

    1dB2 dB4 dB8dB16dB

    TOTALATTEN42dB

    +

    TX

    TX

    TX

    /

    RX

    TX

    /RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXER MODULE

    TX

    TX

    TX

    /

    RX

    TX

    /RX

    FROM

    MCPA

    TO

    ATTEN

    BTS

    ANT

    TRANSMITDUPLEXER MODULE

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    21/22

    21

    47

    24

    22.7526.25

    Outdoor Three Sector Cabinet Mechanical Specification

    No HVAC Required Flexible Mounting Options:

    1. Can be saddle mounted to side of BTS

    or other existing cabinet

    2. Can be mounted on optional Base

    Unit as a free standing unit

    Low Maintenance Design

    All Aluminum Construction

    Powder Coated Finish Weatherproof Construction

    Features & Benefits

    Options

    -1S: Single Sector

    -2S: Two Sector

    -3S: Three Sector

    -1A: Single Active Antenna

    (all carriers on one antenna)

    -2A: Two Active Antennas

    (carriers are distributed between two antennas)

    -4: By-Pass Option

    -5: Redundant Amplifier (N+1) Option

    -I: Indoor Rack

    -O: Outdoor Cabinet

    Model CE1819-200MC XS-YA-Z-*SWhere:

    X = Number of Sectors Required (1, 2 or 3)

    Y = Number of Active Antennas per Sector Required (1 or 2)

    Z = 4 for Bypass Option, or 5 for Redundant Amplifier Option

    * = I for Indoor Rack Mounted, or O for Outdoor Cabinet Mounted - 200W CDMA Cell Extender

    Ordering Information

  • 7/28/2019 CCI 200W Cell Extender System - 1900 - CDMA PCS Edition V1 1

    22/22

    Indoor Three Sector Rack Mechanical Specification