caterpillar - coolon · caterpillar 6060 lighting design simulation report this report is compiled...
TRANSCRIPT
CATERPILLAR6060
Lighting Design Simulation Report
This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application.
Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
SIMULATIONCATERPILLAR 6060OPTION A
CATERPILLAR 6060Lighting Design Simulation Report
2This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
LUMINAIRE SCHEDULE
OPTION A
Model No. Luminaire Optic Type QuantityCP24-L25 CP24 Flood Light L25 - Medium Optics 9
CP24-O209 CP24 Flood Light O209 - Oval Optics 1
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 270°
MODEL CP24OPTIC O209ANGLE 75°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 70°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 160°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 200°
MODEL CP24OPTIC L25ANGLE 65°
DIRECTION 90°
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
3This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
Total LLF: 0.7
ISOLINE VIEW
OPTION A
-80
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
80
0m
10
100
50
25
25
10
10
10
10
5
5
5
5
5
1
1
1
1
1
1
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
4This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
OPERATOR’S VIEW
OPTION ACATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
5This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
SIMULATION
OPTION BCATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
6This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
LUMINAIRE SCHEDULE
OPTION B
Model No. Luminaire Optic Type QuantityCP24-L25 CP24 Flood Light L25 - Medium Optics 2
CP56-L25 CP56 Flood Light L25 - Medium Optics 7
CP56-O209 CP56 Flood Light O209 - Oval Optics 1
CATERPILLAR 6060
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 270°
MODEL CP56OPTIC O209ANGLE 75°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 0°
MODEL CP24OPTIC L25ANGLE 45°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 70°
DIRECTION 0°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 160°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 200°
MODEL CP56OPTIC L25ANGLE 65°
DIRECTION 90°
CATERPILLAR 6060Lighting Design Simulation Report
7This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
ISOLINE VIEW
OPTION B
Total LLF: 0.7
-80
-70
-60
-50
-40
-30
-20
-10
20
30
40
50
60
70
80
0m
10
100
100
100
50
50
50
50
50
25
25
25
25
25
25
10
10
10
10
10
10
5
5
5
5
5
5
1
1
1
1
1
1
1
1
1
CATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
8This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.
OPERATOR’S VIEW
OPTION BCATERPILLAR 6060
CATERPILLAR 6060Lighting Design Simulation Report
9This report is compiled to provide illustrations of product use for a particular application. It is created for evaluation purposes only. Individual machines may vary in configuration, hence affecting results. Please contact us to request a specific design for your application. Coolon recommends that all system upgrades are carried out by a qualified auto electrician.