4 POLE ALTERNATORS

Three-phase brushless synchronous alTernaTors wiTh aVr e1X13/4 - slT - pro18 - pro22 - pro28 - pro35 6

4 pole Three-phase alTernaTors eFFiciency Table 8

sinGle-phase brushless synchronous alTernaTors wiTh aVr e1X13/4 - sls - pro18 - pro22 9

Technical FeaTures e1X/4 - sl - pro 10

accessories For e1X/4 - sl - pro 11

Three-phase synchronous alTernaTors wiTh brushes e1s13/4 12

sinGle-phase brushless synchronous alTernaTors wiTh capaciTor e1c13/4 13

sinGle-phase brushless synchronous alTernaTors wiTh capaciTor For liGThinG Towers aluMen 14

General FeaTures 15

connecTions To The TerMinal board 16

2 POLE ALTERNATORS

sinGle-phase brushless synchronous alTernaTors wiTh capaciTor sp10 - e1c10 - e1c11 - e1c13/2 20

Technical FeaTures sp10-e1c 21

sinGle-phase brushless synchronous alTernaTors wiTh aVr e1X13/2 22

Three-phase brushless synchronous alTernaTors wiTh aVr e1X13/2 23

Technical FeaTures e1X/2 24

Three-phase synchronous alTernaTors wiTh brushes e1s10- e1s11 - e1s13/2 25

Three-phase synchronous alTernaTors wiTh brushes, coMpound and aVr e1s10/Ke - e1s11/Ke 26

General FeaTures 27

TECHNICAL DRAWINGS AND DIMENSIONS 29

TABLE OF CONTENTS

THE COMPANY

linZ elecTric s.p.a., part of the pedrollo Group of companies, is specialized in the production of alternators and rotating welders. it was founded in 2002 and became in few years one of the major players in the sector. The knowledge and long experience of its designers together with the strong propensity for innovation and a natural tendency for investment has quickly led to the development of a full range of products whose high quality standards are recognized and appreciated worldwide by the most important gen-sets manufacturers. in accordance with its deep values the main focus of linz electric has always been the customer satisfaction by controlling the key points of the production through a strong vertical integration, a constant focus on the product Quality and a quick and complete service.

linZ elecTric lands in the states, with a new subsidiary, linZ elecTric inc. based in northbrook, illinois. it is an important step for the company, which will offer to us customers an optimized pre- and after-sales service, quick deliveries and customer support, thanks to the proximity to the market and to the competence that always distinguishes linz electric and its people.

arcole, Verona, italy

northbrook, il, usa

4 POLE ALTERNATORS

6 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH AVR

• 60Hz /1800 RPM - 4 POLES • 0.8 Power Factor • Class H Insulation• 12 Leads (*6 Leads)

model

3 Phase277/480V - High WYe 138/240V - low WYe

kVA

3 Phase 240/416V - High WYe 120/208V - low WYe

kVA

Single Phase120/240V - Series Parallel

kVANet weight SAe

(lbs)

150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40

e1X1

3/4

E1X13S A/4 9 8 7.5 6.5 8 7.5 6.5 5.5 5 5 4.5 4 140

E1X13S B/4 10.5 10 9.5 8.5 9.5 9 8.5 7.5 6 6 5.5 5 154

E1X13S C/4 13 12 11 9.5 12.5 11 10.5 9 8 7 7 6 169

E1X13M E/4 18 17 15.5 13.5 14.5 14 13 11.5 9.5 9 8.5 7.5 212

E1X13M F/4 21 19 17.5 15.5 18.5 17 15.5 13.5 12 11 10 8.5 221

SlT SLT18 MC 19 18 17 15 16.5 16 15 13 11 10.5 10 8.5 251

SLT18 MD 26 24 22 19 24 21 20 17.5 15.5 13.5 13 11.5 256

PRo1

8

PRO18S A/4 26 24 22 19 24 21 20 17.5 15.5 13.5 13 11.5 267

PRO18S B/4 32 30 27.5 24 28.5 26 24 21 18.5 17 15.5 13.5 297

PRO18S C/4 38 36 33.5 29 36 34 32 28 23.5 22 21 18.5 331

PRO18M D/4 45 42 38.5 33.5 40 38.5 36 31.5 26 25 23.5 20.5 375

PRO18M E/4 55 50 47 41 50 48 45 39.5 32.5 31 29.5 26 441

PRO18L F/4 64 60 54 47 58 56 48 42 38 36.5 31 27 522

PRO18L G/4 76 72 66 57.5 62 60 50 43.5 40.5 39 32.5 28.5 590

PRo2

2

PRO22S A/4 83 75 70.5 61.5 71 65 61 53.5 46 42.5 39.5 34.5 581

PRO22S B/4 95 90 83 72.5 86 81 75 65.5 56 52.5 49 43 651

PRO22S C/4 110 100 95 83 100 94 88 77 65 61 57 50 697

PRO22S D/4 130 120 111.5 97.5 118 110 101 88 76.5 71.5 69.5 57 781

PRO22M E/4 167 155 145 126.5 148 139 129 113 96 90.5 84 73.5 957

PRO22M F/4 195 180 167.5 146 162 150 139 121 105 97.5 90.5 79 1046

PRO22M G/4* 210 190 176 153.5 180 165 150 131 117 107 97.5 85 1046

• ip23 proTecTion deGree• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• wiTh auXliary windinG (see page 10)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating

Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian electrical code, part ii)

• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements, ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage30to34

INSULATION SYSTEM 250H

PRO18

7For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH AVR

• 60Hz /1800 RPM - 4 POLES • 0.8 Power Factor • Class H Insulation• 12 Leads (* 6 Leads)

model

3 Phase277/480V - High WYe 138/240V - low WYe

kVA

3 Phase 240/416V - High WYe 120/208V - low WYe

kVA

Single Phase120/240V - Series Parallel

kVANet weight SAe

(lbs)

150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40

PRo2

8

PRO28S A/4 234 215 192 168 213 196 175 153 138 127 114 100 1243

PRO28S B/4 260 240 210 183 245 225 200 175 159 146 130 113 1303

PRO28S C/4 305 270 240 209 290 260 225 196 188 169 146 127 1473

PRO28S D/4 320 300 250 218 310 290 240 209 201 188 156 136 1611

PRO28M E/4 370 360 300 262 345 335 277 242 224 218 180 157 1838

PRo28m F/4 435 420 360 314 400 390 335 292 260 253 218 190 2092

PRO28L G/4* 490 480 430 375 435 430 386 337 283 279 251 219 2280

PRo3

5

PRO35S B/4 575 540 485 423 520 480 440 384 338 312 286 250 2610

PRO35S C/4* 635 600 540 471 575 550 495 432 374 357 322 281 2783

PRO35S D/4 695 660 590 515 615 580 510 445 400 377 331 289 2960

PRO35M E/4* 760 720 660 576 680 640 590 515 442 416 383 334 3294

PRO35M F/4* 840 800 730 637 750 715 650 567 487 465 422 368 3308

PRO35M G/4 920 870 780 681 830 785 700 611 539 510 455 397 3656

PRO35L H/4* 1040 960 935 816 915 870 860 759 595 565 559 493 4116

• ip23 proTecTion deGree• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• wiTh auXliary windinG (see page 10)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating

Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian electrical code, part ii)

• Foroveralldimensionsseefrompage35to36

INSULATION SYSTEM 250H

PRO35

8 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

4 POLE THREE-PHASE ALTERNATORS EFFICIENCY TABLE

model leads

3 Phase277/480V - High WYe 138/240V - low WYe

60 Hz - 1800 rpm - cosφ = 0.8125/40

kVA eff.%

e1X1

3/4

E1X13S A/4 12 8 81E1X13S B/4 12 10 83E1X13S C/4 12 12 84.6E1X13M E/4 12 17 86E1X13M F/4 12 19 86.4

SlT SLT18 MC 12 18 87.4

SLT18 MD 12 24 87.8

PRo1

8

PRO18S A/4 12 24 87.8PRO18S B/4 12 30 88.2PRO18S C/4 12 36 88.8PRO18M D/4 12 42 90.4PRO18M E/4 12 50 91.1PRO18L F/4 12 60 91.2PRO18L G/4 12 72 91.4

PRo2

2

PRO22S A/4 12 76 90.4PRO22S B/4 12 90 90.4PRO22S C/4 12 102 90.6PRO22S D/4 12 120 90.9PRO22M E/4 12 156 92.5PRO22M F/4 12 180 92.8PRO22M G/4 6 192 93.5

PRo2

8

PRO28S A/4 12 215 92.5PRO28S B/4 12 240 92.5PRO28S C/4 12 270 92.7PRO28S D/4 12 300 93.2PRO28M E/4 12 360 93.3PRo28m F/4 12 420 94PRO28L G/4 6 480 94.2

PRo3

5

PRO35S B/4 12 540 95.5PRO35S C/4 6 600 95.9PRO35S D/4 12 660 95.9PRO35M E/4 6 720 95.7PRO35M F/4 6 804 95.4PRO35M G/4 12 870 96.2PRO35L H/4 6 960 96.5

SLT18

INSULATION SYSTEM 250H

9For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

SINGLE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH AVR • 60Hz / 1800 RPM - 4 POLES• 1 Power Factor• Class H Insulation

modelSingle Phase

120/240V - Series ParallelkVA

Net weight SAe(lbs)

eff%cosφ = 1

150/40 125/40 105/40 80/40

e1X1

3/4

E1X13S A/4 6.5 6 5.5 4.8 140 81

E1X13S B/4 7.5 7 7 6 154 82

E1X13S C/4 9.5 9 8 7 169 84.5

E1X13M E/4 13 12.5 11.5 10 212 85.5

E1X13M F/4 15.5 14 13 11.5 221 86

SlS SLS18 MC 13 12 11 9.5 247 85.8

SLS18 MD 18.5 18 16.5 14.5 254 87

PRo1

8

PRO18S A/4 18.5 18 16.5 14.5 267 87

PRO18S B/4 23.5 22 20 17.5 297 87

PRO18S C/4 28 26.5 24.5 21.5 331 88.2

PRO18M D/4 33 30.5 28 24.5 375 90

PRO18M E/4 40 36.5 34.5 30 441 90.6

PRO18L F/4 46.5 44 39.5 34.5 522 90.8

PRO18L G/4 55.5 52.5 48 42 590 92

PRo2

2

PRO22S A/4 58 54 50 44 581 90

PRO22S B/4 69 65 60 55 651 90.2

PRO22S C/4 76 72 67 60 697 90

PRO22S D/4 91 86 80 72 781 90.5

PRO22M E/4 118 112 103 95 957 92

PRO22M F/4 130 125 118 110 1046 92.1

• ip23 proTecTion deGree • coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• wiTh auXliary windinG (see page 10)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials -

General csa-c22.2 no. 0, appendix b, General requirements - canadian electrical code, part ii)• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators,

ul1004-1 2nd ed. rotating electrical Machines–General requirements, ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage30to34INSULATION SYSTEM 250H

E1X13

10 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

MECHANICAL CHARACTERISTICSe1X, sl and pro series are compact, durable and mechanically resistant. The casing, front and rear shields are made of vibration resistant aluminium alloy and steel. The shafts are made of high resistant steel and the bearings are lifelong lubricated. rotors are extremely strong in order to resist the escape velocity of the drive engines and they are equipped with a damping cage to ensure excellent performance even during single-phase distorting and unbalanced three-phase loads.all standard motor couplings used in the market are available.

ELECTRICAL FEATuRESThe rotor and stator insulation is made of class h materials and the winding is tropicalised. The magnetic lamination is low loss rate to ensure maximum performance.

WINdINGS: all windings are all made of class h materials. The quality of the copper undergoes a double check to guarantee the very best standard in the market.Three-phase 12 leads windings are wound to 2/3 pitch to reduce the total harmonic voltage distortion by keeping it constantly within 3% during all electrical function conditions.

dAmPING CAGe: every model in the e1X, sl and pro series has a damping cage as standard which allows the alternator to work in parallel stand-alone or connected to the grid and operating with single-phase distorting and unbalanced three-phase loads. The damping cage on all the models provides added value since the market for applications using electronic loads is growing rapidly (ups , inverter, chopper and switching power supply units). These loads need to be managed by power switching devices with a good quality voltage wave form even when loaded.

AUXIlIARY PoWeR WINdING: The important aim of the auxiliary winding function is to guarantee that the power supply to the electronic regulator is not affected by the load connected to the generator. This winding ensures that the regulator operates perfectly whatever the load type, even with a severe non-linear load.The auxiliary winding is galvanically insulated and independent of the main windings. it has been dimensioned to guarantee a permanent short-circuit current equal to 3 times the rated current for at least 10 seconds, thus providing optimal function during heavy start-up transients of asynchronous motors.This auxiliary winding is the technological answer to the pMG (permanent magnet generator) power supply system, used in the past to support short circuit current, a function that this special auxiliary winding now carries out perfectly.

oVeRloAdS ANd SHoRT CIRCUIT CURReNT: overload of 10% of the rated power for 1 hour every 6 hours is allowed.in case of a three-phase symmetric short circuit, the permanent current is, on average, 300% of the rated current. This value can be sustained for 10 seconds.

THd (ToTAl HARmoNIC dISToRTIoN): with linear and balanced load is less than 3% with or without load (l-l and l-n)

eleCTRoNIC ReGUlAToRS: The voltage regulators are designed, manufactured and tested entirely in our factories. They are made with state-of-the-art electronic components and technologies that ensure reliability and sturdiness under any generator working conditions. Two models are available: single phase voltage reference model hVr-11 and three-phase voltage reference hVr-30 with three separate entrances. The standard e1X-sl-pro alternators series include the following electronic regulators: hVr-11 on e1X, sl, pro18 and pro22 (hVr30 is supplied on request) and hVr-30 on pro28, pro35.

main features of the regulators- Voltage adjustment within the limit of ±1%- stability control adjustment to guarantee the best dynamic response for any situation (type of drive motor or alternator size) - output voltage adjustment - adjustment of the low frequency protection - adjustment of the over-excitation protection setting caused by abnormal loads- remote potentiometer inlet - 50hz or 60hz working possibility- parallel operation with a specific kit (dp01) all adjustments are made with multi-turn trimmers that allow an extremely accurate setting.

TECHNICAL FEATuRES E1X-SL-PRO

11For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

Pd (PARAllel deVICe/dRoP deVICe): This device is recommendend for paralleling two or more alternators. Furthermore, our aVr are equipped with a (0-5)Vdc input to connect external governors running parallel operation. ANTI-CoNdeNSATIoN HeATeRS: anti-condensation heaters, specifically made to apply onto the main stator during the winding final stage production, are available for the entire pro series.

ImPReGNATIoNS FoR mARINe USe: The main stator of all e1X, sl and pro alternators undergoes a standard treatment with a red paint: a protective class F high temperature insulating enamel phenolic resin that can be applied to all the generator wound parts forming a flexible film with excellent mechanical, heat and chemical resistance. it is suggested for use in high humidity or salinity environments.

Characteristics of red insulator:• Excellentchemicalresistancetowater,saltmineralandacids• Oilandmoisturerestistant• Thermalclass:175°C• Excellentheatresistance

PolYBUTAdIeNe ComPoUNd: anytime a better waterproof protection is required, a polybutadiene resin is also available for application onto the main stator.

THeRmAl PRoBeS: on request, thermal capsules with an nc switch (normally closed) and pT100 probes can be fitted into the windings. The pro35 series comes complete with bimetallic thermal protectors.

GeAR BoXeS: The e1X, pro18 and pro22 series can be supplied with gear box for pTo drive.

SUPPReSSIoN oF RAdIo INTeRFeReNCe: all our products comply with the en55014-1, en55011 and Vde0875 directives, guaranteeing a grade G and n level. Moreover, radio interference filters are available in order to match the requirements of the most restrictive norms.

ACCeSSoRIeS e1X13 SlS-SlT PRo18 PRo22 PRo28 PRo35

b3/b14 mounting form • • • • •

Gear box • • •

impregnation for marine environment • • • • • •

polybutadiene compound • • • • • •

regulator hVr30 • • std. std.

ip44 protection filters • •

device for parallel operations • • • std.

eMi filter • • • • • std.

anticondensation heaters • • • • • •

bimetallic thermal protections - pT100 for windings • • • • • std.

pT100 for bearings • • • • • •

ACCESSORIES FOR E1X-SL-PRO

12 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE BRuSHES SYNCHRONOuS ALTERNATORS

• 60Hz / 1800 RPM - 4 POLES• 0.8 Power Factor• Class H Insulation• 6 Leads

model

3 Phase 127/220V or 220/380V

kVANet weight SAe

(lbs)eff%

cosφ = 0.8150/40 125/40 105/40 80/40

e1S1

3/4

E1S13S A/4 10.3 9.6 9 8 128 81.4

E1S13S B/4 13 12 11 9.6 142 83.5

E1S13M D/4 16.5 16 14.5 12.6 171 85

E1S13M E/4 21 19 17.5 15 200 86.3

E1S13M F/4 26 24 22 19 207 86.5

TECHNICAL FEATuRES

VolTAGe: standard 220/380V or 127/220 V at 60 hz . special voltage on request.VolTAGe ACCURACY: ± 4% from no load to full load, cosφ = 0.8 at constant rotation speed.

SHoRT CIRCUIT CURReNT: in case of short circuit the permanent current is 350% of the rated current. This value can be sustained for 10 seconds.

oVeRloAd: 10% overload for one hour every 6 hours is accepted. short overloads can be very high (three times the rated current).

ASYNCHRoNoUS moToRS STARTING: 1 hp per kVa of the generator can be started.

oUTPUT VolTAGe WAVe FoRm: The low harmonic content (<5%) allows supplying any type of load, including distorting loads.

• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• hiGh sTarTinG capaciTy oF inducTiVes loads• hiGh eFFiciency• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)

• Foroveralldimensionsseefrompage38to39

INSULATION SYSTEM 250H

E1S13

13For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

SINGLE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH CAPACITOR

• 60Hz / 1800 RPM - 4 POLES• 1 Power Factor• Class H Insulation

• Mechanically resisTanT • MiniMuM MainTenance• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements,

ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage38to39

model

Single Phase120/240V - Series Parallel

kVANet weight SAe

(lbs)eff%

cosφ = 1150/40 125/40 105/40 80/40

e1C1

3/4

E1C13S A/4 7.5 7 6.5 5.5 113 81.7

E1C13S B/4 9.3 8.5 7.5 6.5 127 82

E1C13S C/4 10.5 9.75 8.8 7.5 141.5 82.6

E1C13S D/4 12 11 10 8.5 151 82.8

E1C13M E/4 14.5 14 12.5 11 184.5 83

E1C13M F/4 16 15 13 11.5 192 83.2

TECHNICAL FEATuRES

e1c13/4 series are single-phase 4 poles brushless alternators with an auxiliary winding loaded onto highly insulated dielectric capacitors regulating the voltage. This series has been designed for application in single-phase generating sets and lighting towers.

VolTAGe ACCURACY: ± 5% from no load to full load, cosφ =1 at constant rotation speed.

SHoRT CIRCUIT CURReNT: in case of short circuit the permanent current exceeds rated current by three times, ensuring the correct operation of protections.

oVeRloAd: a 10% overload for one hour every 6 hours is accepted.

TRANSIeNT VolTAGe dIP AT RATed loAd INSeRTIoN: The voltage dip when the load is inserted is lower than 10% at cosφ =1 and nominal rpm.

INSULATION SYSTEM 250H

E1C13

14 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

SINGLE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS FOR LIGTHING TOWERS

• 60Hz / 1800 RPM - 4 POLES• 1 Power Factor• Class H Insulation

model

Single Phase120/240 V- Series Parallel

kVANet weight SAe

(lbs)150/40 125/40 105/40 80/40

AlUm

eN

ALuMEN SB 4.5 4.2 3.8 3.4 69

ALuMEN MD 6.5 6 5.5 4.8 90.5

ALuMEN LE 8.8 8 7.5 6.5 104.5

ALuMEN LF 11 10 9.2 8 122

• sinGle, all-in-one aluMiniuM alTernaTor• coMpacT and easy To asseMble• FleXible desiGn (w/o capacitor box, damping cage, terminal board)• easy MainTenance• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems

of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian electrical code, part ii)

• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements, ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseepage37

TECHNICAL FEATuRES

aluMen series is a set of single-phase 4 poles brushless alternators with an auxiliary winding loaded onto highly insulated dielectric capacitors, regulating the voltage. This series has been specifically designed for application in lighting towers with metal halide, halogen or led lamps. alumen is compact, easy to assemble thanks to an all-in-one frame design and low-maintenance thanks to accessible and screwed diodes. it has a flexible and customizable design to fit all needs: w/o capacitor box and damping cage, with cables direct output or with terminal board.

VolTAGe ACCURACY: ± 5% from no load to full load, cosφ =1 at constant rotation speed.

SHoRT CIRCUIT CURReNT: in case of short circuit the permanent current exceeds rated current by three times, ensuring the correct operation of protections.

oVeRloAd: a 10% overload for one hour every 6 hours is accepted.

TRANSIeNT VolTAGe dIP AT RATed loAd INSeRTIoN: The voltage dip when the load is inserted is lower than 10% at cosφ =1 and nominal rpm.

INSULATION SYSTEM 250H

kVA

Eff%cosφ = 1

ALuMEN ALuMEN-Xwithout damping cage

4.2 75.8 78.4

6 81.4 82.5

8 82.3 84.5

10 82.6 84.1

EFFICIENCY TABLE

ALuMEN

REFERENCE STANDARDSour alternators series are built in accordance with the provisions specified in the :• en 60034-1, en 60204-1, en61000-6-2, en61000-6-4, en 55014-1, en 55011 standards • 2006/95/ce and 2004/108/ce directives• curus - recognized insulation system under ul1446 standard (file number e481753)

e1X, sl, pro18,pro22, e1c13/4 and aluMen series are listed by csa Group as certified (ccsaus - can/csa - c22.2 no.100-14 ) and are also built in accordance with ul 1004-1 and ul1004-4 (file number 260717)

OPERATING CONDITIONSThe performance data reported in the present catalogue are valid for operation at an altitude not exceeding 1000m (3300 ft) and ambient temperature not exceeding 40°c (104°F). if operation takes place in different conditions, consult the table below.

15For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

Power variation according to temperature and altitude

AlTITUde m / ft

Ambient temperature25°C/77°F 40°C/104°F 45°C/113°F 50°C/122°F 55°C/131°F

< 1000 / 3300

1.09 1 0.96 0.93 0.91

1000-1500 / 3300-4900

1.01 0.96 0.92 0.89 0.87

1500-2000 /4900-6600

0.96 0.91 0.87 0.84 0.83

2000-3000 / 6600-9900

0.9 0.85 0.81 0.78 0.76

GENERAL FEATuRES

16 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

series high wye (series star)

parallel low wye (parallel star)

series delta

parallel delta

Zig-Zag

double delta (single phase connection)

12 wires

CONNECTIONS TO THE TERMINAL BOARD

hz l-n l-l

60 240 - 415

254 - 440

266 - 460

277 - 480

50 220 - 380

230 - 400

240 - 415

254 - 440

hz l-n l-l

60 120 - 208

127 - 220

133 - 230

139 - 240

50 110 - 190

115 - 200

120 - 208

127 - 220

hz l-n l-l

60 240

254

266

277

50 220

230

240

254

hz l-n l-l

60 120

127

133

139

50 110

115

120

127

hz l-n l-l

60 208 - 360

220 - 380

230 - 400

240 - 415

50 191 - 330

200 - 346

208 - 360

220 - 380

hz l-M l-l

60 120 - 240

127 - 254

133 - 266

139 - 277

50 110 - 220

115 - 230

120 - 240

127 - 254

17For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

CONNECTIONS TO THE TERMINAL BOARD

series high wye (series star)

series delta

6 wires

hz l-n l-l

60 240 - 415

254 - 440

266 - 460

277 - 480

50 220 - 380

230 - 400

240 - 415

254 - 440

hz l-n l-l

60 240

254

266

277

50 220

230

240

254

2 POLE ALTERNATORS

20 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

SINGLE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH CAPACITOR • 60Hz / 3600 RPM- 2 POLES• 1 Power Factor• Class H Insulation

model

Single Phase120/240V - Series Parallel

kVANet weight

(lbs)eff%

cosφ = 1150/40 125/40 105/40 80/40

SP10

SP10S A 2.2 2 1.8 1.6 25 73.5

SP10S B 3 2.7 2.4 2.1 29.8 74.5

SP10S C 3.5 3.2 2.9 2.5 33 75.5

SP10S D 4 3.7 3.3 2.9 36 76

SP10S E 4.7 4.3 3.9 3.4 39 76.5

SP10M F 5.5 5 4.7 4.1 43.6 77

SP10M G 6.6 6 5.5 4.8 46.3 77.5

model

Single Phase120/240V - Series Parallel

kVANet weight

(lbs)eff%

cosφ = 1150/40 125/40 105/40 80/40

e1C1

0

E1C10S B 3 2.7 2.4 2.1 34.8 74.5

E1C10S D 4 3.7 3.3 2.9 39.7 76

E1C10S E 4.7 4.3 3.9 3.4 44 76.5

E1C10S F 5.5 5 4.7 4.1 47 77

E1C10S G 6.6 6 5.5 4.8 50.7 77.5

E1C10M H 7.9 7.25 6.8 6 64.6 79

E1C10M I 9.3 8.5 8 7 71.2 80.5

E1C10M L 10.5 9.75 9 7.8 81.0 79.5

e1C1

1 E1C11M B 13.7 12.5 11.5 10 105.4 80

E1C11M C 16.4 15 13 11.5 115 80.5

e1C1

3/2 E1C13M D/2 20 18 17 15 170.6 81.5

E1C13M E/2 24 22 20 17.5 195 82.1

• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements,

ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage38to44

INSULATION SYSTEM 250H

INSULATION SYSTEM 250H

SP10

E1C10

21For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

VolTAGeS: For sp and e1c standard 120/240V, 60hz. special voltages on request.

VolTAGe ACCURACY: For sp and e1c series ± 5% from no load to full load, cosφ =1 at constant rotation speed.

SHoRT CIRCUIT CURReNT: For sp and e1c series in case of short circuit the permanent current exceeds rated current by three times, ensuring the correct operation of protections.

oVeRloAd: a 10% overload for one hour every 6 hours is accepted.

oUTPUT VolTAGe WAVe FoRm: The low harmonic content (<5%) allows supplying any type of single-phase load: therefore electrical appliances with electronic regulation, computers, motors, TV sets, etc. can be used.

TRANSIeNT VolTAGe dIP AT RATed loAd INSeRTIoN: The voltage dip when the load is inserted is lower than 10% at cosφ =1 and nominal rpm.

TECHNICAL FEATuRES SP10-E1C

22 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

SINGLE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH AVR

• 60Hz /3600 RPM - 2 POLES • 1 Power Factor• Class H Insulation

model

Single Phase120/240V - Series Parallel

kVANet weight SAe

(lbs)eff%

cosφ = 1150/40 125/40 105/40 80/40

e1X1

3/2

E1X13S A/2 8 7.5 7 6.5 134 80.5

E1X13S B/2 9.7 9 8.4 7.8 145.5 81.5

E1X13S C/2 13 12 11 10 161 84.2

E1X13M D/2 16 15 14 13 198.5 86

E1X13M E/2 21.5 20 18.5 17.5 222.5 86.8

• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• wiTh auXliary windinG (see page10)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements,

ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage30to31

INSULATION SYSTEM 250H

E1X13

23For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE BRuSHLESS SYNCHRONOuS ALTERNATORS WITH AVR

• 60Hz /3600 RPM - 2 POLES • 0.8 Power Factor• Class H Insulation• 12 Leads

model

3 Phase277/480V - High WYe 138/240V - low WYe

kVA

3 Phase 240/416V- High WYe 120/208V - low WYe

kVA

Single Phase120/240V - Series Parallel

kVANet weight SAe

(lbs)

150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40 150/40 125/40 105/40 80/40

e1X1

3/2

E1X13S A/2 11 10 9.2 8 9.8 9 8.2 7.5 6.3 5.5 5 4.5 134

E1X13S B/2 13.5 12.5 11.5 10 12 11 10 8.7 7.5 7 6.5 5.7 145.5

E1X13S C/2 16.4 15 14 12 14 13 12 10.5 9 8.5 8 7 161

E1X13M D/2 21 19.5 18 16 18.2 17 15.5 14 11.5 11 10 9 198.5

E1X13M E/2 28 26 24 21 24.5 23 21 18.5 16 15 13.7 12 223

• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• MiniMuM MainTenance• hiGh eFFiciency• wiTh auXliary windinG (see page 10)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)• cCSAus CERTIFICATION (standards: can/csa –c22.2 no. 100-14 (r2009) Motors and Generators, ul1004-1 2nd ed. rotating electrical Machines–General requirements,

ul1004-4 2nd ed. electric Generators)

• Foroveralldimensionsseefrompage30to31

MODEL Leads

3 Phase277/480V - High WYe

138/240 - low WYe60 Hz - 1800 rpm - cosφ = 0.8

125/40kVA eff.%

E1X13S A/2 12 10 80.6

E1X13S B/2 12 12.5 82

E1X13S C/2 12 15 83.4

E1X13M D/2 12 19.5 85.5

E1X13M E/2 12 26 86.2

EFFICIENCY TABLE

24 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL FEATuRES E1X/2

VolTAGe: e1X alternators are equipped with a 12 terminal winding leading to an operating voltages as reported at page 16. special voltage on request.

WINdING: double layer with shortened 2/3 pitch (shortening factor=0,866) to ensure low harmonic content.

VolTAGe ACCURACY: ± 1% from no load to full load with cosφ ranging from 0.8 to 1 and constant rotation speed.

SHoRT CIRCUIT CURReNT: in case of a three-phase symmetric short circuit, the permanent current is, on average, 300% of the rated current. This value can be sustained for 10 seconds.

oVeRloAd: 10% overload for 1 hour every 6 hours is normally accepted. short overloads can be very high (3 times the rated current).

SINGle-PHASe oPeRATING: The single-phase output power is 40% of the three-phase rated power when using just one phase with a y connection or 65% of the three-phase rated power when using a delta connection.

eleCTRoNIC ReGUlATIoN : The e1X series is equipped with the last generation of the hVr11 electronic regulation. all adjustments are made with multi-turn trimmers that allow an extremely accurate setting. The main features of the regulator are:- output voltage adjustment within the limit of ±1%- stability control adjustment to guarantee the best dynamic response for any situation (type of drive motor or alternator size) - adjustment of the low frequency protection - adjustment of the over-excitation protection setting caused by abnormal loads- remote potentiometer inlet - 50hz or 60hz working possibility.

VolTAGe WAVe FoRm: The wave form of the no-load line voltage or applying a balanced linear three-phase load is sinusoidal with an harmonic residual less than 4%.

25For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE SYNCHRONOuS ALTERNATORS WITH BRuSHES

• 60Hz / 3600 RPM- 2 POLES• 0.8 Power Factor• Class H Insulation

model

3 Phase 127/220V or 220/380V

kVANet weight

(lbs)eff%

cosφ = 0.8150/40 125/40 105/40 80/40

e1S1

0

E1S10M G 7.7 7 6.5 5.7 63.3 79

E1S10M H 9.3 8.5 8 7 73 81

E1S10M I 12 11 10 9 81.4 82.5

E1S10L L 13 12 11 9.7 91.3 82.7

e1S1

1 E1S11M AS 15 14 13 11.5 100 83.5

E1S11M B 18 16.5 15.5 13.6 113.5 84

e1S1

3 E1S13S C/2 21 19.2 17.5 15.5 134.5 85.5

E1S13M D/2 28 26.4 24 21 170.6 86.5

E1S13M E/2 35 32.4 29.5 26 195 87.5

• coMpacT and Mechanically resisTanT • eXcellenT waVe ForM• hiGh sTarTinG capaciTy oF inducTiVes loads• hiGh eFFiciency• wiTh auXliary windinG (see page 7)• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)

• Foroveralldimensionsseepages38,39,45and46

TECHNICAL FEATuRES E1S

VolTAGe: standard 220/380 or 127/220 at 60hz. special voltage on request.

VolTAGe ACCURACY: ± 4% for e1s and ±1% for e1s-Ke from no load to full load, cosφ = 0.8 at constant rotation speed.

SHoRT CIRCUIT CURReNT: in case of short circuit the permanent current is 350% of the rated current. This value can be sustained for 10 seconds.

oVeRloAd: 10% overload for one hour every 6 hours is accepted. short overloads can be very high (three times the rated current).

ASYNCHRoNoUS moToRS STARTING: 1 hp per kVa of the generator can be started.

oUTPUT VolTAGe WAVe FoRm: The low harmonic content (<5%) allows supplying any type of load, including distorting loads.

INSULATION SYSTEM 250H

E1S13

26 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

THREE-PHASE ALTERNATORS WITH BRuSHES, COMPOuND AND AVR

• 60Hz / 3600 RPM- 2 POLES• 0.8 Power Factor• Class H Insulation

model

3 Phase127/220V or 220/380V

kVANet weight

(lbs)eff%

cosφ = 0.8150/40 125/40 105/40 80/40

e1S1

0 - Ke

E1S10M G-KE 6 5.4 5 4.7 63.3 79

E1S10M H-KE 7.5 7 6.3 5.8 73 81

E1S10M I-KE 9.3 8.5 7.8 7 81.4 82.5

E1S10L L-KE 12 11 10 9 92.8 82.8

e1S1

1-Ke E1S11M AS-KE 13.2 12.5 11.5 10.5 100 83.7

E1S11M B-KE 15 14 12.8 11.8 113.5 84

AdVANTAGeS oF THe “Ke“ ReGUlATIoNThe “Ke” system, envisaging the combined use of a particular compound and an electronic regulation, solves the typical inconveniences of an exclusively compound or electronic regulation. The electronic regulator has an ad-hoc delayed load insertion time to allow the compound to act during the transient voltage dip. after that period of time, the electronic regulation resumes the operations by correcting the output voltage. The generator can operate with both the compound regulation alone and the electronic regulation alone, increasing the reliability of the machine in case of failure of one of the two systems.

• coMpacT and Mechanically resisTanT• eXcellenT waVe ForM• hiGh sTarTinG capaciTy oF inducTiVes loads and ±1% VolTaGe reGulaTion• hiGh eFFiciency• uL RECOGNIZED INSuLATION SYSTEM (standards: ul 1446, systems of insulating Materials - General csa-c22.2 no. 0, appendix b, General requirements - canadian

electrical code, part ii)

• Foroveralldimensionsseefrompage45to46

INSULATION SYSTEM 250H

E1S10

27For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

GENERAL FEATuRES

MECHANICAL SPECIFICATIONSThe sp and e1 series are manufactured by means of advanced technology and high quality materials. The frame is made of vibration-resistant aluminium alloy. The shaft is in high tensile steel. The rotor is designed to resist the runaway speed of the traction motors, and comes with a damping cage allowing correct operation also in case of distorted loads. The bearings are life-long lubricated. axial ventilation is ensured with intake from the side opposite to the coupling. both rotation directions are possible.all the motor coupling standards available on the market are supported.

ELECTRICAL FEATuRESinsulation is obtained with h class material for both stator and rotor and the windings are tropicalized. low-loss lamination is used.

REFERENCE STANDARDSour alternators series are built in accordance with the provisions specified in the :• en 60034-1, en 60204-1, en61000-6-2, en61000-6-4, en 55014-1, en 55011 standards • 2006/95/ce and 2004/108/ce directives• curus - recognized insulation system under ul1446 standard (file number e481753)

sp, e1c and e1X13/2 series are listed by csa Group as certified (ccsaus - can/csa - c22.2 no.100-14 ) and are also built in accordance with ul 1004-1 and ul1004-4 (file number 260717).

OPERATING CONDITIONSThe performance data reported in the present catalogue are valid for operation at an altitude not exceeding 1000m (3300 ft) and ambient temperature not exceeding 40°c (104°F). if operation takes place in different conditions, consult the table below.

Power variation according to temperature and altitude

AlTITUde m / ft

Ambient temperature25°C/77°F 40°C/104°F 45°C/113°F 50°C/122°F 55°C/131°F

< 1000 / 3300

1.09 1 0.96 0.93 0.91

1000-1500 / 3300-4900

1.01 0.96 0.92 0.89 0.87

1500-2000 /4900-6600

0.96 0.91 0.87 0.84 0.83

2000-3000 / 6600-9900

0.9 0.85 0.81 0.78 0.76

TECHNICAL DRAWINGS

TECHNICAL DRAWINGS AND DIMENSIONS E1X13S

30 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1X13M

31For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS SLS-SLT

32 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS PRO18

33For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS PRO22

34 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS PRO28

35For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS PRO35

36 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS ALuMEN

37For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1C13S-E1S13S

38 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1C13M-E1S13M

39For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS SP10

40 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS SP10

41For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1C10S

42 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1C10M

43For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1C11

44 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1S10M-L

45For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

TECHNICAL DRAWINGS AND DIMENSIONS E1S11

46 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

The features and specifications herein stated are in no way binding for linZ elecTric s.p.a. linZ elecTric s.p.a. is free to modify the product at any time without previous notice.

48 For more information and support contact: T.+1 (847) 595 1473 - [email protected] - www.linzelectric.us

Find us on:distributor:LINz ELECTRIC INC.3005 commercial ave.northbrook, il 60062 - usaT.+1 (847) 595 [email protected]

manufacturer:LINz ELECTRIC S.P.A. Viale del lavoro 3037040, arcole (Verona), italy T.+39 (045) 7639 [email protected]