catalogue 2012 - ekotermija.lvekotermija.lv/attachments/article/33/ecoflam catalogue 2012.pdf ·...

60
www.ecoflam-burners.com Customised soluons for all types of applicaon CATALOGUE 2012 A complete range of burners for all fuels MONOBLOCK 20 - 17000 kW DUOBLOCK 350 - 25000 kW GAS BURNERS LIGHT OIL BURNERS HEAVY OIL BURNERS GAS/LIGHT OIL BURNERS GAS/HEAVY OIL BURNERS DUOBLOCK BURNERS

Upload: nguyenque

Post on 30-May-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

www.ecoflam-burners.com

Customised solutions for all types of application

CATALOGUE 2012

A complete range of burners for all fuelsMONOBLOCK 20 - 17000 kWDUOBLOCK 350 - 25000 kW

GAS BURNERS

LIGHT OIL BURNERS

HEAVY OIL BURNERS

GAS/LIGHT OIL BURNERS

GAS/HEAVY OIL BURNERS

DUOBLOCK BURNERS

3www.ecoflam-burners.com

COMPANY PROFILE

Ecoflam Bruciatori S.p.A. is a specialist in combustion technologies and a worldwide brand recognised for the reliability of its burners, the competence of its technical team and the wide offer of customised solutions for heating and industry applications.

Ecoflam was established in 1973 in Castelfranco Veneto, near Venice in the North East of Italy. Throughout the time Ecoflam has continued to develop products with constant devotion and determination addressing:Technological Research, Ecology, Energy Saving and Safety.

Ecoflam Bruciatori S.p.A. since 2005 has been incorporated into the Burners Division of Ariston Thermo Group and today takes advantage of the group synergies and offers a full range of blown air pressure jet burners for all fuels in monoblock and duoblock version up to 25 MW.

Ecoflam burners guarantee high efficiency and reliable operation combined with functional features that reduce installation time and maintenance. Manufacturing is carried out in the factory of Resana (Treviso - Italy) in accordance with ISO 9001:2008 and products are distributed worldwide thanks to its network of partners.

BURNER APPLICATIONS

Heating applications

Metal industry applications

Asphalt plants and building industry applications

Incinerators applications and waste industry

Modernisation of plants and other applications

Agriculture applications

Food industry applications

Textile, glass and ceramic industry applications

Chemical and petrolchemical industry applications

Wood and solid fuel applications

www.ecoflam-burners.com4

INDEX

RANGE OF PRODUCTS 5-7

Designation 8-9Ecoflam range - modular delivery system 10-11

CATALOGUE STRUCTURE 12-13

Gas train composition - EN676 configurations and export 14Gas train - Kit - Accessories assembly to the burner 15Electronic version with Burner Management System 16-17TS range - Duoblock burners 16-17

LIGHT OIL BURNERS 18

MAX 19-20MAIOR 21-22

HEAVY OIL BURNERS 23

MAXFLAM 24OILFLAM 24-25Forced oil preparation ring 26

GAS BURNERS 27

MAX GAS 28-32BLU 33-40

DUAL FUEL BURNERS (GAS/LIGHT OIL) 41

MULTICALOR 42-47

DUAL FUEL BURNERS (GAS/HEAVY OIL) 48

MULTIFLAM 49-51

GAS TRAIN - KITS - ACCESSORIES

Gas train: MAX GAS 52Gas train - GTCP: BLU - MULTICALOR - MULTIFLAM 53Accessories for gas 54KIT - ACS for gas 55KIT - ACS: Load controller - Probe 56Silencer 56KIT - ACS: Oil options 57Diagnostic tool for Thermowatt control 57

BURNER SELECTION FORM 58-59

5www.ecoflam-burners.com

MAIOR P 1800.1

MAIOR P 1500.1

MAIOR P 1200.1

MAIOR P 1000.1

MAIOR P 800.1

MAIOR P 700.1

MAIOR P 600.1

MAIOR P 500.1

MAIOR P 400.1

MAIOR P 300.1

MAIOR P 200.1

MAIOR P 150.1

MAIOR P 120

MAIOR P 80

MAIOR P 60

0 1000 2000 3000 4000 5000 6000 kW

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW

415 710

830 1423

592 1780

2417 7500

2750 8500

3300 10500

4367 12500

5000 15000

5700 17000

710 2372

1000 3000

1300 3900

1578 5000

1795 5800

474 949

MAX P 35

MAX P 45

MAX P 25

MAX P 15

MAX P 12

MAX 30

MAX 20

MAX 15

MAX 12

MAX 8

MAX 4 Low NOx

MAX 4

MAX 1 Low NOx

MAX 1 41,4

20 59

22,5

0 100 200 300 400 500 600 kW

47,4

17,6

17,6

35,5

47 105

60 130

60 130

73,4 190

77 190

102 300

166 427

202 546

86,4 237

110 319

MAXFLAM 50 AB

MAXFLAM 30

MAXFLAM 20

MAXFLAM 10 68 136

170 340

205 410

205 570

227108

464 930

1700

2093

682

682

30001000

39001300

50001578

58001795

75002417

85002750

105003300

125004367

150005000

170005700

682 1395

MAXFLAM 30 AB

0 100 200 300 400 500 600 kW

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW

OILFLAM 1800.1

OILFLAM 1500.1

OILFLAM 1200.1

OILFLAM 1000.1

OILFLAM 800.1

OILFLAM 700.1

OILFLAM 600.1

OILFLAM 500.1

OILFLAM 400.1

OILFLAM 300.1

OILFLAM 200.1

OILFLAM 170.1

OILFLAM 120.1

OILFLAM 80.1

LIGHT OIL RANGE

HEAVY OIL RANGE

www.ecoflam-burners.com6

DUAL FUEL (GAS/LIGHT OIL) RANGE

700270

1770

2150

342

414

3000630

3900875

50001200

58001500

75001500

85002000

105002500

130002700

150003690

170004000

875280

1200260

1100290

1550300

245 970

0 200 400 600 800 1000 1200 1400 1600 1800 2000 kW

BLU 700.1 Low NOx

BLU 1000.1

BLU 1000.1 Low NOx

BLU 1200.1

BLU 1200.1 Low NOx

BLU 1500.1 Low NOx

BLU 18000.1

BLU 15000.1

BLU 12000.1

BLU 10000.1

BLU 8000.1

BLU 7000.1

BLU 6000.1

BLU 5000.1

BLU 4000.1

BLU 3000.1

BLU 2000.1

BLU 1700.1

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW

MULTICALOR 140 PR

MULTICALOR 140 AB

MULTICALOR 100 PR-AB

MULTICALOR 100 AB

MULTICALOR 70 PR-AB

MULTICALOR 70 AB

MULTICALOR 45 AB700250

1770

2150

342

414

3000630

3900875

50001200

58001500

75001500

85002000

105002500

130002700

150003690

170004000

1000300

1000200

1300400

1300250

190 700

190 500

0 200 400 600 800 1000 1200 1400 1600 1800 2000 kW

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW

MULTICALOR 1800.1

MULTICALOR 1500.1

MULTICALOR 1200.1

MULTICALOR 1000.1

MULTICALOR 800.1

MULTICALOR 700.1

MULTICALOR 600.1

MULTICALOR 500.1

MULTICALOR 400.1

MULTICALOR 300.1

MULTICALOR 200.1

MULTICALOR 170.1

MAX GAS 500

MAX GAS 350

MAX GAS 250

MAX GAS 170

MAX GAS 120 PAB

MAX GAS 120

MAX GAS 105

MAX GAS 70

MAX GAS 40 17 48

34 70

49 108

49 120

55 170

55 240

100 350

120 500

40 120

0 100 200 300 400 500 600 kW

GAS RANGE

7www.ecoflam-burners.com

DUOBLOCK RANGE

414 2150

3900

5000

875

1200

58001500

75001500

85002000

105002500

130002700

150003690

170004000

630 3000

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 kW

MULTIFLAM 1800.1

MULTIFLAM 1500.1

MULTIFLAM 1200.1

MULTIFLAM 1000.1

MULTIFLAM 800.1

MULTIFLAM 700.1

MULTIFLAM 600.1

MULTIFLAM 500.1

MULTIFLAM 400.1

MULTIFLAM 300.1

MULTIFLAM 200.1

PLATFORM 260

PLATFORM 280

PLATFORM 320

PLATFORM 380

PLATFORM 630

PLATFORM 710

PLATFORM 800

Min VSD

Min kW

Max kW

Oil 120 300 450 1400

Gas 1500.1 250 300 1550

Min VSD

Min kW

Max kW

Oil 200.1 500 710 2372

Gas 2000.1 350 414 2150

Min VSD

Min kW

Max kW

Oil 400.1 700 875 3900

Gas 4000.1 500 875 3900

Min VSD

Min kW

Max kW

Oil 600.1 1050 1500 5800

Gas 6000.1 725 1500 5800

Min VSD

Min kW

Max kW

Oil 1800.1 3200 5700 17000

Gas 18000.1 2100 4000 17000

Min VSD

Min kW

Max kW

Oil 800.1 1600 2000 8500

Gas 8000.1 1050 2000 8500

Oil 1200.1 2400 2700 13100

Gas 1200.1 1600 2700 13100

Min VSD

Min kW

Max kW

Oil 2500.1 5000 7000 25000

Gas 25000.1 3200 6000 25000

2000 40000 3000 5000 kW1000

2000 40000 3000 5000 kW1000

0 2000 40003000 5000 kW1000

0 10000 15000 kW5000

1000050000 15000 kW

0 10000 2000015000 25000 kW5000

0 10000 2000015000 25000 kW5000

Note: Oil/Gas indicates the output range for light oil, heavy oil, gas and dual fuel burners.

DUAL FUEL (GAS/HEAVY OIL) RANGE

www.ecoflam-burners.com8

BURNER DESIGNATION

ELECTRICAL POWER SUPPLY230-50 230 V, 50 Hz230-50-60 230 V, 50-60 Hz230-400-50 230/400 V, 50 Hz110-50-60 110 V, 50-60 Hz

FUEL- Gas / Light oil / Heavy oilLPG Liquid gasBIOGAS BiogasKER KeroseneB10 Biodiesel

HEAD TYPETC Short headTL Long head

OPERATION TYPE- 1 stage R 1 stage with pre-heaterP 1 stage - soft startPAB 2 stages gas - soft startP 120 AB 2 stages light/heavy oil 120 kg/h - soft startP 120 AB HS 2 stages oil hydraulic system 120 kg/h - soft startZ3 / S3 2 stages with 3 nozzles / 3 stages with 3 nozzlesPR 2 stages progressive mechanicalPR-PAB 2 stages progressive mechanical gas / 2 stages oilMD 2 stages modulating mechanical with PIDE 2 stages modulating electronic

EMISSIONSLN - Low NOx Low NOx Class 3 - GAS EN676 (<80 mg/kWh)- Standard Class 2 - GAS EN676 (<120 mg/kWh)MAX Low NOx Low NOx Class 3 yellow flame (<120 mg/kWh)MAX Standard Class 2 - OIL EN267 (<185 mg/kWh)MAIOR Standard Class 1 - OIL EN267 (<250 mg/kWh)

MODEL SIZE (gas: kW; oil: kg/h)MAX 4 4 kg/h MAIOR 120 120 kg/h MAX GAS 40 40 kWBLU 1200.1 1200 kWMULTICALOR 300.1 300 kg/h - 3000 kW

RANGE NAME + TS Duoblock burner

CONFIGURATION / ADDITIONAL INFOHT High temperatureD D pump version for light oil (max visc. 5°E at 20°C)SGT Separate gas trainNS Without silencer

ELECTRICAL EQUIPMENT (CONTROL BOX)TW ThermowattLFL.../LAL.../LGK... SiemensLMV... Siemens electronicETO Lamtec Etamatic OEMBT3 Lamtec BT300

RANGE NAME BY FUEL TYPEMAX GAS Gas natural - LPGBLU Gas natural - LPGMAX Light oilMAIOR Light oilMAXFLAM Heavy oil (max visc. 50°E at 50°C)OILFLAM Heavy oil (max visc. 50°E at 50°C)MULTICALOR Dual fuel: gas/light oilMULTIFLAM Dual fuel: gas/heavy oil (max visc. 50°E at 50°C)

BLU 1200.1 LN PAB TL SGT 230-50 TW

9www.ecoflam-burners.com

GAS TRAIN DESIGNATION

GAS TRAIN VALVE MANUFACTURERD DungsK KromschröderS Siemens - LandisH HoneywellB Brahma

GAS TRAIN MATCHING BURNERMAXGAS40-120 Model matching MAX GAS 40-120BLU/MULTI Model matching BLU-MULTICALOR-MULTIFLAM rangeMAXGAS40-120SX Left side connection for MAX GAS 40-120

VALVE NOMINAL DIAMETERRP15 Rp. 1/2" Threaded connectionRP20 Rp. 3/4" Threaded connectionRP25 Rp. 1" Threaded connectionRP32 Rp. 1"1/4 Threaded connectionRP40 Rp. 1"1/2 Threaded connectionRP50 Rp. 2" Threaded connectionDN40 DN40 Flanged connectionDN50 DN50 Flanged connectionDN60 DN60 Flanged connectionDN80 DN80 Flanged connectionDN100 DN100 Flanged connectionDN125 DN125 Flanged connection

MODEL TYPEMBC120 MultiBloc model MBC120MBDLE403 MultiBloc model MBDLE403MBZRDLE410 MultiBloc 2 stages valve model MBZRDLE410VGD20503 Siemens Landis model VGD20503VCS240 Kromschröder model VCS240EG12L Brahma model EG12L

OPERATION TYPE1 1 stage or 2 stages with butterfly valve2 2 stages solenoid valve3 2 stages pneumatic4 2 stages electronic5 2 stages mechanical

KITTC-VPS504VCS

GT - S2 - VGD40 - DN80 - BLU/MULTI

KIT - ACS DESIGNATION

PROBE-WATER130CGTCP-DN80-260/280/320

Kit tightness control VPS504 for VCS gas valve

Water probe up to 0÷130° С

Connection pipe for gas train DN80 platform 260/280/320

OPT / STD / ACS Optional / Standard / Accessory

www.ecoflam-burners.com10

ECOFLAM RANGE

Ecoflam burners have been designed and built in compliance with all current regulations and directives. All burners comply to the safety and energy saving operation regulations withinthe standard of their respective performance range. The quality is guaranteed by a quality and management system certified in accordance with ISO 9001:2008.

GAS BURNERS AND DUAL FUEL BURNERS

Ecoflam gas and dual fuel burners are delivered in compliance to the applicable standards. All burners from 3 MW are supply by default with silencer. Gas train is delivered separately with different configurations. Kits and accessories shall be included in the gas train and in the burner as described in the Catalogue Structure (scope of supply) in accordance to the instruction and local safety regulations and codes of practise.

GAS TRAIN - GTCP - KITS - ACCESSORIESAll gas and dual fuel burners gas trains are delivered separately in different models and configuration. Export configuration gas train completion are available but it is mandatory for the local installer in this case to comply to the local safety regulations. For burners over 1700 kW gas train connection pipe must be ordered.Kits and accessories are managed and delivered separately.

All gas burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kit and accessories that shall complete the gas train or the burner according to the applicable standard.Kit and accessories are delivered separately.

All dual fuel burners are delivered in separate set/box, i.e. burner body including combustion head and separate gas train with separate additional kit and accessories that shall complete the gas train or the burner according to the applicable standard.Kit and accessories are delivered separately.

Configurated and special version on request with burner selection form.

ISO9001:2008

COMPONENT TYPE

CB Complete Burner (for light oil / heavy oil)

BBCH Burner Body with Combustion Head (without gas train)

BB Burner Body

CH Combustion HeadGTCP Gas Train Connection Pipe

GT Gas Train (delivered separately)

SV Separate Ventilator for duoblock burner

11www.ecoflam-burners.com

BURNER SELECTION: Type of operation and configuration must be done by professional personnel in order to grant correct working of the burner. Installation, start-up and maintenance must be carried out by authorised specialists andall applicable guidelines and regulations (including local safety regulations and codes of practise) must be observed.

LIGHT OIL AND HEAVY OIL BURNERS

Ecoflam oil burners are delivered in compliance to the applicable standards. All burners from 3 MWare supplied by default with silencer. Additional accessories and options shall be installed by the installer in accordance to the instruction and local safety regulations and codes of practise.

All light oil burners are delivered complete in one single packaging including filter and flexible hoses up to 6 MW.

All heavy oil burners are delivered with electrical pre-heater preassembled into the burner body, including filter and flexible hoses up to 6 MW.

Configurated and special version on request with burner selection form.

DUOBLOCK BURNERS

Ecoflam offers selected models/outputs in duoblockversion for all the fuels that can be delivered based on the configuration requested (mechanical or electronic) from the client in order to better fit into the application and provide a customised and more cost effective solution.

ECOFLAM RANGE

!

www.ecoflam-burners.com12

CATALOGUE STRUCTURE

BURNER COMPOSITION - Scope of supply for all burners include the following parts:

BBCHBURNER BODYwith COMBUSTION HEAD

Light oilHeavy oil

BBCH is delivered in one single boxAdditional KIT-ACS to be ordered and delivered separately

GasDual fuel

BBCH - GT - ACS are delivered in separate boxesAdditional KIT-ACS to be ordered and delivered separately

DuoblockBBCH - GT - ACS are delivered in separate boxesSV and additional KIT-ACS to be ordered and deliveredseparately

Electronic versionwith BMS

BBCH - GT - ACS are delivered in separate boxesAvailable from 2 MW with loosen electrical panel or separate electrical or switch cabinet

SILENCERUp till 2 MW platform 280

From 3 MW platform 320

Silencer is complementary and can be ordered as aseparate KITSIL-…

Silencer is included by default for Monoblock burners

GTCPGAS TRAINCONNECTION PIPE

Size Gas train vs Diameter Connection

To be included from the platform 280 (≈1700 kW)

WARNING: its size and fitting depends on the burner and the gas train selected

GTGAS TRAIN SEPARATE *

Export configurationEN676 completion

* Min working pressure = Pressure drop inlcudes “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676

MultiBlocMB

Gas MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switch

SiemensVGD

Double gas valves with actuators and regulator VGD Siemens and min pressure switch + ACS gas filterDefault blank spring: head pressure 0...22 mbar

WARNING: from BLU 3000.1 - MULTICALOR 300.1 - MULTIFLAM 300.1 change spring and damping

KromschröderVCS

Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filter

Export configuration Export completion gas train depending on the models shall be completed in compliance with local safety regulations.

GAS GOVERNOR& FILTER

GAS FILTER

FGDR / FS1BGas pressure governor and filter model FGDR,operating pressure range up to 500 mbar.FS1B up to 1 bar.

SPRING FGDRFGDR: default spring is neutral for outlet pressurerange 10-30 mbarFor different outlet setting range please change the spring according to our technical documentation

FILTERGas filter to complete VGD gas trains,operating pressure up to 1 bar.(Suggested as additional for all installations)

13www.ecoflam-burners.com

KIT - ACCESSORIES - CONFIGURATIONS

DIAGNOSTIC TOOL KITDT-TW Diagnostic tool for Thermowatt control box

TIGHTNESS CONTROL KITTC-...Gas leakage control device for gas trainsDifferent models depending on the type of gas trainCompulsory for EN676 over 1200 kW – 1032000 kcal/h

MAXIMUM GAS PRESSURE SWITCH KITPRES... Maximum gas pressure switch - kit

To be installed in order to comply local safety regulations

ADDITIONAL KITS ACCESSORIES KIT - ACS Additional kits and accessories

To be installed in order to comply local safety regulations

For full modulating version: BURNER BODY PR + PID REGULATOR & PROBE

PID CONTROLLER KITMD-...KITMD-RWF40

Modulation of burner can be done also from the PID of the boiler panel

MATCHING PROBE PROBE-... Matching probe for hot water - air - steam

Additional Kits & Accessories

KITS

KITLPG-...LPG transformation kit for gas burnerSee related models and technical documentation for operating gas pressure

KITADAPT-... Adaptor for gas train connectionMAX GAS range for LPG

KITPOT-... Kit Potentiometer

KITxx-... Other KITs: see related pages

ACCESSORIES

ACS Antivibration coupling

ACS Ball valve

ACS Manometer + Push button

ACS Magnetic + Selfcleaning oil filter

ACS Other ACS: see related pages

FLEXSHOP Configurations - Service

Configurations can be implemented in the factory from our internal FLEXSHOP

Swirl systemAvailable for different fuel burner headSwirls for blast tube that can reduce flame lenght up to 10-50% depending on fuel, backpressure and shape of combustion chamber

KITCV Continuous Ventilation Available for different burnerKit for burner with Thermowatt control box

Other Special configurations will be evaluated on request

AFTER SALE SERVICE CONTRACTS

Ecoflam Service Department can offer start up service contracts

SPARE PARTS Ecoflam original spare parts

CATALOGUE STRUCTURE

www.ecoflam-burners.com14

GAS TRAIN COMPOSITION - EN676 CONFIGURATIONS AND EXPORTEcoflam gas trains are delivered separately for all gas and dual fuel burners and are available in different configuration and models:

• EN676 standard gas train + kit/accessories in compliance with EN676;• Export configuration + others additional options to be added by instal-ler in compliance with local safety regulations and codes of practise;• KIT and accessories: shall be fitted by the installer in accordance to the instruction and local safety regulations and codes of practise.

PRESSURE DROP includes: “COMBUSTION HEAD + GAS TRAIN + GAS GOVERNOR & FILTER” as per EN676.Back pressure of boiler/application must be added/included in order to have the total min pressure drop.

Double solenoid valves VCS Kromschröder and min pressure switch + ACS gas governor & filterVCS 125 R/LW Rp 1” - VCS 240 R/LW Rp 1”1/2 - VCS 350 R/LW Rp 2” 1. Main gas pipe

2. Ball valve ACS3. Antivibrating coupling ACS4. Gas governor & filter ACS

EN67

65. Min. gas pressure switch

Expo

rt GAS TRAIN6. Safety gas valve

7. Working gas valve8. Gas leakage control KITTC *KIT - Max. gas pressure switch KITPRESACS - Gas train connection pipe GTCP **

1 2 3 4 78 65

MultiBloc Dungs: compact double solenoid valve with integrated filter, regulator and min pressure switchMB-DLE 407 - MB-DLE 410 - MB-DLE 412 - MB-DLE 415 - MB-DLE 420 1. Main gas pipe

2. Ball valve ACS3. Antivibrating coupling ACS5. Min. gas pressure switch

EN67

6 GAS TRAIN

EN67

66. Safety + Working gas valve7. Gas governor and filter included8. Gas leakage control KITTC *KIT - Max. gas pressure switch KITPRESACS - Gas train connection pipe GTCP **

1 2 3 865

7

** WARNING: From BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1, in order to fit the gas train, the corresponding connection pipe must be ordered (GTCP size and fitting depend on the burner and the gas train selected).

* EN676 CONFIGURATION: for gas train VCS include gas governor and filter and for VGD include filter.KITTC-... Tightness control device (VPS - VDK - LDU) must be included over 1200 kW according to EN676.

!

!

!

Double gas valves with actuators and regulator VGD Siemens and min pressure switch + ACS gas filterVGD 20.503 Rp 2” / VGD 40.065 - 40.080 - 40.100 - 40.125 1. Main gas pipe

2. Ball valve ACS3. Antivibrating coupling ACS5. Min. gas pressure switch

Expo

rt GAS TRAIN

EN67

66. Safety gas valve + 10. Actuator7. Working gas valve + 11. Actuator8. Gas leakage control KITTC *9. Gas filter ACSKIT - Max. gas pressure switch KITPRESACS - Gas train connection pipe GTCP **

1 2 3 9 118 105

67

Default blank spring: head pressure 0...22 mbar. Yellow spring: head pressure 15...120 mbar

From BLU 3000.1 - MULTICALOR 300.1 - MULTIFLAM 300.1 change spring and damping

15www.ecoflam-burners.com

GAS TRAIN - KIT - ACCESSORIES ASSEMBLY TO THE BURNER

HOW TO INSTALL THE GAS TRAIN INTO THE BURNER AND CALCULATE THE OVERALL DIMENSIONS

* WARNING: From BLU 1700.1 - MULTICALOR 170.1 - MULTIFLAM 300.1:in order to fit the gas train the corresponding connection pipe must be ordered.

KIT AND ACCESSORIES

WARNING: EN676 compulsory kit and accessories in order to comply to the safety regulations. Additional accessories and kits shall be installed by the installer in accordance to the local safety regulations and codes of practise.

MAX GAS 40 ÷ 250

Gas train withconnection on the top

MAX GAS 350 ÷ 500BLU 700.1 ÷ 1500.1MULTICALOR 45 ÷ 140 Gas train with right hand side connection

BLU 1700.1 ÷ 18000.1MULTICALOR 170.1 ÷ 1800.1MULTIFLAM 300.1 ÷ 1800.1

Gas train with connection at the bottom and right (or left with kit) hand side layout

DUOBLOCK

Gas train with connection at the bottom and right or left hand side layout

!

!

Gas governor / Filter Tightness control Modulation Kit Max Pressure switch LPG Transformation

FGDR - FILTER KITTC- Model KITMD-RWF40 KITPRES50 KITLPG-MAXGAS...

Compulsory EN676 Compulsory over 1200 kW PROBE-... KITPRES150 KITLPG-BLU...

www.ecoflam-burners.com16

ELECTRONIC VERSION WITH BURNER MANAGEMENT SYSTEM

CAN-Bus

PGASmin PGAS

LT

PAIR

TPPOILmax

POILmin

M

BUSmu l t i

TS RANGE - DUOBLOCK BURNERS

Available models for different fuels in standard progressive mechanical configuration with derivative electrical panel.

Electronic version with Burner Management System with separate switch cabinet on request.

Platform Max output range Light oil Heavy oil Gas Gas - Light oil Gas - Heavy oil260 0,8 ÷ 1,5 MW Maior 120 Oilflam 120.1 Blu 1500.1 Multicalor 140 Multiflam 120280 1,5 ÷ 2 MW Maior 200.1 Oilflam 200.1 Blu 2000.1 Multicalor 200.1 Multiflam 200.1320 3 ÷ 4 MW Maior 400.1 Oilflam 400.1 Blu 4000.1 Multicalor 400.1 Multiflam 400.1380 5 ÷ 6 MW Maior 600.1 Oilflam 600.1 Blu 6000.1 Multicalor 600.1 Multiflam 600.1630 7 ÷ 9 MW Maior 800.1 Oilflam 800.1 Blu 8000.1 Multicalor 800.1 Multiflam 800.1630 10 ÷ 13 MW Maior 1200.1 Oilflam 1200.1 Blu 12000.1 Multicalor 1200.1 Multiflam 1200.1710 15 ÷ 18 MW Maior 1800.1 Oilflam 1800.1 Blu 18000.1 Multicalor 1800.1 Multiflam 1800.1800 22 ÷ 25 MW Feasibility only on request

SELECTED OUTPUT TO MATCH MAIN BOILERSAND INDUSTRIAL APPLICATION

Ecoflam offers the electronic range with BMS from 2 MW up to 17 MW in monoblock and up to 25 MW in duoblock configuration with electrical panel assembled into the burner or on request with separate switch cabinet.

For all burners the delivery scope is in a modular system i.e.:

• BBCH: burner body with combustion head;• GT: gas train; • KIT - ACS: kits and accessories can complete the burner in order to comply to the local safety regulations and codes of practise;• Heavy oil and dual fuel gas-heavy oil are deli-vered with pre-heater assembled into the burner body or on request in a separate frame/skid;• SV: separate ventilator for duoblock version.

17www.ecoflam-burners.com

INVERTER SYSTEMVSD module is an extension to the BMS and is used for the control of a variable speed drive, that allows electrical comsumption saving, lower noise emission, gradual fan starting and reduction of mechanical stress.

O2-CO TRIM CONTROLO2-CO allows the control of the residual oxygen content in order to increase the boiler efficiency.

ModelTurndown ratio Kit Kit Additional

functionsstandard with inverter oil side VSD - inverter O2-CO trim

MAIOR 200.1-1800.1 1÷5 1÷5 1÷5 Kit Kit Flame monitoring

sensors

Communication interfaces

Display interface

OILFLAM 200.1-1800.1 1÷5 1÷5 1÷5 Kit KitBLU 2000.1-18000.1 1÷6 1÷8 - Kit KitMULTICALOR 200.1-1800.1 1÷6 1÷8 1÷5 Kit KitMULTIFLAM 200.1-1800.1 1÷6 1÷8 1÷5 Kit KitDUOBLOCK 1÷6 1÷8 1÷5 Kit Kit

Flamesensors

TemperaturePressuresensors

Communicationinterface

LeakageSystem

Display Actuators O2 Trim CO Trim VSD Inverter

MONITORING APPLICATIONReliable and safe flame detection system for single and multiple burner furnaces.

RANGE OF OUTPUT WITH BURNER MANAGEMENT SYSTEM

MONOBLOCK - DUOBLOCK RANGE WITH BMS

Electronic compound manager for burner has been introduced into Ecoflam range in order to improve performance and efficiency of modern firing installation. BMS is a compact powerful solution suitable for the control and supervision of single or dual fuel forced draft burners. This system is designed to be matched with an extensive range of components such as flame, temperature and pressure sensors, gas valves, variable speed fan motors and oxygen control that can be managed from different bus interfaces.

BMS solutions are meant to bring the main following benefits:

• significant energy saving in both fuel and electricity;• optimal process performance and minimise costs;• simple commissioning and operating in total safety;• integrated solution with a wide range of communications interfaces;• combustion optimisation with O2/CO control;• effective diagnostic and real time status information;• user interface easy to use and program.

www.ecoflam-burners.com18

MAX

- M

AIO

R -

M

ax v

isc.

1,5

° E a

t 20°

C

LIG

HT O

IL B

URN

ERS

MAX

rang

e fo

r lig

ht o

il co

mbi

nes a

hig

h effi

cien

cy fa

n ve

ntila

tion

syst

em (H

PV) w

ith fe

atur

es ra

ngin

g fr

om e

asy

mat

chin

g on

boi

lers

up

to e

asy

mai

nten

ance

and

set u

p.

The

rang

e is

avai

labl

e in

stan

dard

cla

ss 2

and

Low

NO

x em

issio

n cl

ass 3

yel

low

flam

e ac

cord

ing

to E

N26

7.

The

rang

e fit

s sta

ndar

d he

ating

and

ligh

t ind

ustr

y ap

plic

ation

s.

MAI

OR

rang

e fo

r lig

ht o

il ar

e av

aila

ble

in tw

o st

ages

with

hyd

raul

ic sy

stem

or s

ervo

mot

or

up to

350

kg/

h an

d fr

om th

e m

odel

MAI

OR

45 in

pro

gres

sive

oper

ation

that

can

be

turn

ed

in m

odul

ating

with

a P

ID re

gula

tor.

MAI

OR

mod

els o

ver 7

MW

are

offe

red

on re

ques

t bas

ed o

n th

e co

nfigu

ratio

n re

ques

ted

(mec

hani

cal o

r ele

ctro

nic)

in o

rder

to b

etter

fit i

nto

the

appl

icati

on a

nd p

rovi

de

a cu

stom

ised

and

mor

e co

st e

ffecti

ve so

lutio

n.

DUO

BLO

CK a

nd E

LECT

RON

IC v

ersio

ns a

re a

vaila

ble

on re

ques

t for

sele

cted

out

put

to m

atch

mai

n bo

ilers

and

indu

stry

app

licati

on.

KIT

- ACS

(see

ded

icat

ed p

ages

)•

KIT

Biod

iese

l•

KIT

Wie

land

plu

gs•

Ligh

t oil

pum

p un

it on

requ

est

• PI

D m

odul

ating

KIT

and

pro

be•

Diag

nosti

c to

ol fo

r TW

con

trol

box

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t•

CV: C

ontin

uous

ven

tilati

on v

ersio

n•

HT: H

igh

tem

pera

ture

ver

sion

• D

pum

p: li

ght o

il w

ith m

ax v

iscos

ity 5

°E a

t 20°

C•

OEM

and

spec

ial a

pplic

ation

ver

sion

only

on

requ

est

All l

ight

oil

burn

ers a

re d

eliv

ered

com

plet

e in

one

sing

le p

acka

ging

incl

udin

g fil

ter a

nd

flexi

ble

hose

s up

to 6

MW

.

19www.ecoflam-burners.com

MAX

LIG

HT O

IL B

URN

ERS

One

stag

e Lo

w N

Ox

clas

s 3 (N

Ox

< 12

0 m

g/kW

h) -

TW -

B10

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

axM

AX 1

R L

ow N

Ox

17,6

35,5

1,5

3TC

3142

713

MAX

4 R

Low

NO

x22

,547

,41,

94

TC31

4272

2

One

stag

e cl

ass 2

(NO

x <

185

mg/

kWh)

- TW

- B1

0

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

1

17,6

41,4

1,5

3,5

TC31

4270

9TL

3142

710

MAX

420

591,

75

TC31

4271

4TL

3142

715

MAX

847

105

48,

9TC

3142

716

TL31

4271

7

MAX

12

6013

05,

111

TC31

4271

8TL

3142

719

MAX

15

73,4

190

6,2

16TC

3142

729

TL31

4273

0

MAX

20

86,4

237

7,3

20TC

3142

731

TL31

4273

2

MAX

30

110

319

9,3

27TC

3142

733

TL31

4273

4

One

stag

e w

ith p

re-h

eate

r ver

sion

s (N

Ox

< 18

5 m

g/kW

h) -

TW -

B10

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

1 R

2039

1,5

3,5

TC31

4271

1TL

3142

712

MAX

4 R

2059

1,7

5TC

3142

720

TL31

4272

1

KIT

- ACC

ESSO

RIES

desc

riptio

nDi

agno

stic

tool

for T

W c

ontr

ol b

oxse

e ac

cess

orie

s pag

e

www.ecoflam-burners.com20

MAX

LIG

HT O

IL B

URN

ERS

Two

stag

es c

lass

2 (N

Ox

< 18

5 m

g/kW

h)

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

P 3

5 AB

166

427

1436

TC31

4229

9TL

3142

300

MAX

P 4

5 AB

202

546

1746

TC31

4230

3TL

3142

304

One

stag

e cl

ass 2

(NO

x <

185

mg/

kWh)

- TW

- B1

0

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

4 H

T20

591,

75

TC31

4272

4TL

3142

723

MAX

8 H

T47

105

48,

9TC

3142

726

TL31

4272

5

MAX

12

HT60

130

5,1

11TC

3142

728

TL31

4272

7

MAX

15

HT73

,419

06,

216

TC31

4273

5TL

3142

736

MAX

20

D HT

86,4

237

7,3

20TC

3142

737

TL31

4273

8

MAX

30

D HT

110

319

9,3

27TC

3142

739

TL31

4274

0

MAX

P 3

5 AB

HS

D HT

166

427

1436

TC31

4310

1TL

3143

102

MAX

P 4

5 AB

HS

D HT

202

546

1746

TC31

4310

3TL

3143

104

Two

stag

es h

ydra

ulic

syst

em c

lass

2 (N

Ox

< 18

5 m

g/kW

h) -

TW -

B10

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

P 1

2 AB

HS

6013

05,

111

TC31

2409

4TL

3124

095

MAX

P 1

5 AB

HS

7719

06,

516

TC31

2270

8TL

3122

709

MAX

P 2

5 AB

HS

102

300

8,6

25,4

TC31

2271

0TL

3122

274

MAX

P 3

5 AB

HS

166

427

1436

TC31

4230

1TL

3142

302

MAX

P 4

5 AB

HS

202

546

1746

TC31

4230

5TL

3142

306

D pu

mp:

max

visc

osity

5°E

at 2

0°C;

HT:

hig

h te

mpe

ratu

re; T

W: T

herm

owatt

con

trol

box

; B10

: oil

pum

p w

ith v

itton

seal

s for

bio

dies

el

21www.ecoflam-burners.com

MAI

OR

LIG

HT O

IL B

URN

ERS

Two

stag

es h

ydra

ulic

syst

em

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

ax

MAI

OR

P 60

AB

HS41

571

035

60O

PTTC

3140

151

TL31

4015

2

MAI

OR

P 60

AB

HS D

415

710

3560

OPT

TC31

4157

2TL

3141

571

MAI

OR

P 80

AB

HS47

494

940

80O

PTTC

3121

063

TL31

2106

4

MAI

OR

P 12

0 AB

HS

830

1423

7012

0O

PTTC

3121

065

TL31

2106

6

MAI

OR

P 15

0.1

AB H

S59

217

8050

150

OPT

TC31

2106

7TL

3121

068

MAI

OR

P 20

0.1

AB H

S71

023

7260

200

OPT

TC31

2106

9TL

3121

070

MAI

OR

P 30

0.1

AB H

S10

0030

0085

250

STD

TC31

4015

3TL

3140

154

MAI

OR

P 40

0.1

AB H

S Z3

1300

3900

110

350

STD

TC31

4015

5TL

3140

156

Two

stag

es

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

ax

MAI

OR

P 60

AB

415

710

3560

OPT

TC31

2101

6TL

3122

265

MAI

OR

P 80

AB

474

949

4080

OPT

TC31

2101

8TL

3122

266

MAI

OR

P 12

0 AB

830

1423

7012

0O

PTTC

3121

020

TL31

2226

9

MAI

OR

P 15

0.1

AB59

217

8050

150

OPT

TC31

2102

2TL

3121

021

MAI

OR

P 20

0.1

AB71

023

7260

200

OPT

TC31

2102

4TL

3121

023

MAI

OR

P 30

0.1

AB10

0030

0085

250

STD

TC31

2102

6TL

3122

272

MAI

OR

P 40

0.1

AB Z

313

0039

0011

035

0ST

DTC

3121

028

TL31

2102

7

www.ecoflam-burners.com22

MAI

OR

LIG

HT O

IL B

URN

ERS

Two

stag

es p

rogr

essi

ve m

echa

nica

l

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

axM

AIO

R P

45 P

R29

653

225

45O

PTTL

on re

ques

tM

AIO

R P

60 P

R41

571

035

60O

PTTL

on re

ques

tM

AIO

R P

80 P

R47

494

940

80O

PTTL

on re

ques

tM

AIO

R P

120

PR83

014

2370

120

OPT

TLon

requ

est

MAI

OR

P 15

0.1

PR59

217

8050

150

OPT

TLon

requ

est

MAI

OR

P 20

0.1

PR71

023

7260

200

OPT

TLon

requ

est

MAI

OR

P 30

0.1

PR10

0030

0085

250

STD

TC31

2104

5TL

3121

046

MAI

OR

P 40

0.1

PR13

0039

0011

035

0ST

DTC

3121

047

TL31

2104

8

MAI

OR

P 50

0.1

PR15

7850

0013

442

2ST

DTC

3121

049

TL31

2105

0

MAI

OR

P 60

0.1

PR17

9558

0015

349

0ST

DTC

3121

051

TL31

2105

2

Two

stag

es p

rogr

essi

ve m

echa

nica

l

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

axM

AIO

R P

700.

1 PR

2417

7500

205

634

STD

TC

-M

AIO

R P

800.

1 PR

2750

8500

234

718

STD

TC

-M

AIO

R P

1000

.1 P

R33

0010

500

281

887

STD

TC

-M

AIO

R P

1200

.1 P

R43

6712

500

371

1053

STD

TC

-M

AIO

R P

1500

.1 P

R50

0015

000

422

1265

STD

TC

-M

AIO

R P

1800

.1 P

R57

0017

000

481

1433

STD

TC

-

KIT

- ACC

ESSO

RIES

desc

riptio

nSi

lenc

erse

e ac

cess

orie

s pag

eM

odul

ation

kit

see

acce

ssor

ies p

age

Prob

ese

e ac

cess

orie

s pag

ePu

mpi

ng u

nit

see

acce

ssor

ies p

age

Kit W

iela

nd p

lugs

see

acce

ssor

ies p

age

MAI

OR

- DU

OBL

OCK

AN

D EL

ECTR

ON

IC B

URN

ERS

Vers

ions

from

2 to

25

MW

are

ava

ilabl

e on

requ

est f

or se

lect

ed o

utpu

t to

mat

ch m

ain

boile

rs a

nd in

dust

ry a

pplic

ation

.

23www.ecoflam-burners.com

MAX

FLAM

- O

ILFL

AM -

Max

vis

c. 5

0° -

100°

E at

50°

C

HEAV

Y O

IL B

URN

ERS

MAX

FLAM

and

OIL

FLAM

rang

e w

ork

with

hea

vy o

il up

to 5

0°E

at 5

0°C

with

On/

Off

switc

h to

exc

lude

the

circ

uit h

eate

rs in

ord

er to

ope

rate

also

with

low

visc

osity

hea

vy o

il.

M10

0 co

nfigu

ratio

n fo

r hea

vy o

il up

to 1

00°E

at 5

0°C

is av

aila

ble

on re

ques

t.

OIL

FLAM

mod

els f

rom

300

.1 a

re su

pplie

d w

ith “G

EFRA

N”

digi

tal t

herm

o re

gula

tor i

nteg

rate

d on

the

fron

t pan

el fo

r gra

nting

tem

pera

ture

stab

ility

of f

uel.

Av

aila

ble

vers

ion

incl

udes

dou

ble

stag

e up

to 3

50 k

g/h

and

from

the

mod

el O

ILFL

AM 3

00.1

in

pro

gres

sive

oper

ation

that

can

be

turn

ed in

mod

ulati

ng w

ith a

PID

regu

lato

r.

Easy

mai

nten

ance

syst

em is

inte

grat

ed in

to th

e bu

rner

:•

HIN

GE F

LAN

GE S

YSTE

M fo

r OIL

FLAM

80.

1 to

200

.1 a

nd 1

500.

1 to

180

0.1

• SL

IDIN

G BA

R SY

STEM

for M

AXFL

AM 1

0 to

50

and

OIL

FLAM

300

.1 to

120

0.1

OIL

FLAM

mod

els o

ver 7

MW

are

offe

red

on re

ques

t bas

ed o

n th

e co

nfigu

ratio

n re

ques

ted

(mec

hani

cal o

r ele

ctro

nic)

in o

rder

to b

etter

fit i

nto

the

appl

icati

on a

nd p

rovi

dea

cust

omise

d an

d m

ore

cost

effe

ctive

solu

tion.

DUO

BLO

CK a

nd E

LECT

RON

IC v

ersio

ns a

re a

vaila

ble

on re

ques

t for

sele

cted

out

put

to m

atch

mai

n bo

ilers

and

indu

stry

app

licati

on

KIT

- ACS

(see

ded

icat

ed p

ages

)•

KIT

Wie

land

plu

gs•

KIT

mag

netic

+ se

lfcle

anin

g fil

ter

• PI

D m

odul

ating

KIT

and

pro

be

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t•

M10

0 ve

rsio

n fo

r hea

vy o

il up

to 1

00°E

at 5

0°C

• Fr

om O

ILFL

AM 3

00.1

pre

-hea

ter c

an b

e su

pplie

d se

para

tely

with

ext

ra c

ost

• Fo

rced

oil

prep

arati

on ri

ng sy

stem

on

requ

est

All h

eavy

oil

burn

ers a

re d

eliv

ered

with

ele

ctric

al p

re-h

eate

r pre

asse

mbl

edin

to th

e bu

rner

bod

y, in

clud

ing

filte

r and

flex

ible

hos

es u

p to

6 M

W.

www.ecoflam-burners.com24

MAX

FLAM

HEAV

Y O

IL B

URN

ERS

One

stag

e - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

FLAM

10

6813

66

12TC

3142

594

TL31

4259

5

MAX

FLAM

20

108

227

9,5

20TC

3142

596

TL31

4259

7

MAX

FLAM

30

170

340

1530

TC31

4259

8TL

3142

599

Two

stag

es -

50°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

blas

t tub

eco

dem

inm

axm

inm

ax

MAX

FLAM

30

AB

205

410

1836

TC31

4260

0TL

3142

601

MAX

FLAM

50

AB

205

570

1850

TC31

4260

2TL

3142

603

OIL

FLAM

Two

stag

es -

50°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

ax

OIL

FLAM

80.

1 AB

46

493

041

82O

PTTC

3142

604

TL31

4260

5

OIL

FLAM

120

.1 A

B 68

213

9560

122

OPT

TC31

4260

6TL

3142

607

OIL

FLAM

170

.1 A

B 68

217

0060

148

OPT

TC31

4260

8TL

3142

609

OIL

FLAM

200

.1 A

B 68

220

9360

184

OPT

TC31

4261

0TL

3142

611

OIL

FLAM

300

.1 A

B 10

0030

0088

,526

4ST

DTC

3142

612

TL31

4261

3

OIL

FLAM

400

.1 A

B Z3

1300

3900

115

343

STD

TC31

4261

4TL

3142

615

25www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

axO

ILFL

AM 8

0.1

PR

464

930

4182

OPT

TLon

requ

est

OIL

FLAM

120

.1 P

R 68

213

9560

122

OPT

TLon

requ

est

OIL

FLAM

170

.1 P

R 68

217

0060

148

OPT

TLon

requ

est

OIL

FLAM

200

.1 P

R 68

220

9360

184

OPT

TLon

requ

est

OIL

FLAM

300

.1 P

R 10

0030

0088

,526

4ST

DTC

3142

616

TL31

4261

7

OIL

FLAM

400

.1 P

R 13

0039

0011

534

3ST

DTC

3142

618

TL31

4261

9

OIL

FLAM

500

.1 P

R 15

7850

0014

044

0ST

DTC

3142

620

TL31

4262

1

OIL

FLAM

600

.1 P

R 17

9558

0015

951

0ST

DTC

3142

622

TL31

4262

3

Two

stag

es p

rogr

essi

ve m

echa

nica

l - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]flo

w ra

te [k

g/h]

silen

cer

blas

t tub

eco

dem

inm

axm

inm

axO

ILFL

AM 7

00.1

PR

2417

7500

214

660

STD

TC-

OIL

FLAM

800

.1 P

R 27

5085

0024

374

8ST

DTC

-O

ILFL

AM 1

000.

1 PR

33

0010

500

292

924

STD

TC-

OIL

FLAM

120

0.1

PR

4367

1250

038

610

97ST

DTC

-O

ILFL

AM 1

500.

1 PR

5000

1500

044

013

19ST

DTC

-O

ILFL

AM 1

800.

1 PR

57

0017

000

501

1495

STD

TC-

KIT

- ACC

ESSO

RIES

desc

riptio

nSi

lenc

erse

e ac

cess

orie

s pag

eM

odul

ation

kit

see

acce

ssor

ies p

age

Prob

ese

e ac

cess

orie

s pag

eHe

ating

and

pum

ping

uni

tse

e ac

cess

orie

s pag

eM

agne

tic +

self

clea

ning

filte

rse

e ac

cess

orie

s pag

e

Vers

ions

from

2 to

25

MW

are

ava

ilabl

e on

requ

est f

or se

lect

ed o

utpu

t to

mat

ch m

ain

boile

rs a

nd in

dust

ry a

pplic

ation

.

OIL

FLAM

- DU

OBL

OCK

AN

D EL

ECTR

ON

IC B

URN

ERS

OIL

FLAM

www.ecoflam-burners.com26

FORC

ED O

IL P

REPA

RATI

ON

RIN

G

All i

nsta

llatio

ns u

sing

heav

y oi

l bur

ners

hav

e to

be

com

plet

ed w

ith a

FO

RCED

OIL

PRE

PARA

TIO

N R

ING

in o

rder

to g

uara

ntee

oil

supp

ly

to th

e bu

rner

at s

uita

ble

tem

pera

ture

and

pre

ssur

e (te

mpe

ratu

re

+/- 8

0° C

, pre

ssur

e 3

bar)

.

For h

eavy

oil

with

mor

e th

an 5

0°E

at 5

0°C

Ecofl

am re

com

men

ds

to d

ecre

ase

the

max

imum

out

put o

f 10-

20%

and

wor

k in

ecc

ess o

f air

in o

rder

to g

rant

bett

er o

pera

tion

and

redu

ce m

aint

enan

ce.

STAN

DARD

SYS

TEM

CO

MPO

SITI

ON

FO

R LI

GHT

OIL

AN

D HE

AVY

OIL

HEA

TIN

G A

ND

PUM

PIN

G U

NIT

I. Fe

edin

g an

d fil

terin

g sy

stem

II. F

uel h

eatin

g sy

stem

for r

educ

ing

oil v

isco

sity

pl

us se

rvic

e ta

nk

III. F

orce

d oi

l sup

ply

syst

em “

RIN

G”

HEAV

Y O

IL P

REPA

RATI

ON

RIN

G -

SUG

GES

TED

SCHE

ME

PRE-

HEAT

ER U

NIT

Ecofl

am h

eavy

oil

burn

ers a

re d

eliv

ered

w

ith e

lect

rical

pre

-hea

ter a

ssem

bled

into

th

e bu

rner

bod

y or

in a

sepa

rate

skid

.Ad

ditio

nal F

orce

d sy

stem

“O

IL R

ING

” ca

n be

des

ign

and

deliv

ered

ass

embl

ed o

n sk

id/f

ram

e or

offe

red

as si

ngle

com

pone

nt.

ACCE

SSO

RIES

Serv

ice

tank

s + P

umps

uni

ts.

Quo

tatio

n on

requ

est d

epen

ding

on

outp

ut a

nd c

onfig

urati

on.

MAG

NET

IC +

SEL

F CL

EAN

ING

FILT

ERTh

e fil

terin

g sy

stem

ope

ratio

n: th

e fir

st m

agne

tic

filte

r allo

ws t

o se

para

te a

ll fe

rrou

s im

puriti

es

cont

aine

d in

the

oil a

nd th

e se

cond

lam

ella

r fil

ter a

llow

s the

fina

l filtr

ation

of a

ll im

puriti

es.

hot w

ater

pip

e / s

team

pip

e

hot w

ater

pip

e / s

team

pip

e

Retu

rn

sec�

on

oil p

ipe

oil p

ipe

elec

trica

l hea

�ng

cabl

ein

sula

�on

AA

TT

BB

11

8 7

12 13

55

33

4

6

79

10

1 1

sez.

:A-

AB-

B

2

LEG

ENDA

1. B

urne

rs2.

Ser

vice

tank

3. E

lect

ric h

eate

rs

4. S

afet

y an

d op

erati

on th

erm

osta

t 5.

Lev

el sw

itch

(wor

king

+ sa

fety

)6.

Hea

ting

coil

7. S

elf c

lean

ing

oil fi

lter

8. L

oad

pum

ps

9. R

ing

pum

ps10

. Oil

ring

cont

rol p

ress

ure

devi

ce11

. Hea

ting

cabl

e12

. Mai

n he

avy

oil s

tora

ge ta

nk13

. Hea

ting

coil

HEAV

Y O

IL W

ARN

ING

S!

27www.ecoflam-burners.com

GAS

BU

RNER

S

MAX

GAS

-

Low

NO

x cl

ass 3

(< 8

0 m

g/kW

h)

MAX

GAS

rang

e is

avai

labl

e in

the

follo

win

g ve

rsio

ns a

nd is

del

iver

ed in

a m

odul

ar sy

stem

of b

oxes

:•

P: 1

stag

e so

ft st

art

• PA

B: 2

stag

es•

PR: 2

stag

es p

rogr

essiv

e m

echa

nica

l

BBCH

: Bur

ner B

ody

with

Com

busti

on H

ead

→ T

C sh

ort h

ead

and

TL lo

ng h

ead

GT: G

as tr

ain

sepa

rate

→ E

N67

6 or

Exp

ort c

onfig

urati

onKI

T &

ACS

: Kits

and

acc

esso

ries a

ccor

ding

to lo

cal r

ules

inst

alla

tion

All M

AX G

AS a

re d

eliv

ered

for n

atur

al g

as a

nd c

an o

pera

te w

ith L

PG b

y ch

angi

ng th

e no

zzle

with

a k

it.M

AX G

AS tw

o st

ages

are

com

plet

e w

ith tw

o st

ages

Mul

tiBlo

c va

lves

MBZ

RDLE

for t

he m

odel

s 120

-250

w

here

mod

els 3

50-5

00 o

pera

te in

two

stag

e w

ith b

utter

fly v

alve

. Pr

ogre

ssiv

e ve

rsio

n ar

e av

ailb

le fo

r mod

els M

AX G

AS 3

50-5

00 a

nd c

an b

e tr

ansf

orm

ed in

to m

odul

ating

w

ith th

e PI

D KI

TMD-

RWF4

0.

EN67

6 co

nfigu

ratio

n:

• Ga

sMul

tiBlo

c Du

ngs:

com

pact

dou

ble

sole

noid

val

ve w

ith in

tegr

ated

filte

r, re

gula

tor a

nd m

in p

ress

ure

switc

h•

Doub

le so

leno

id v

alve

s VCS

Kro

msc

hröd

er: d

oubl

e so

leno

id v

alve

s inc

ludi

ng m

in g

as p

ress

ure

switc

h +

sepa

rate

gas

gov

erno

r an

d fil

ter F

GDR

EXPO

RT c

onfig

urati

on (o

ther

add

ition

al o

ption

s to

be a

dded

by

inst

alle

r in

com

plia

nce

with

loca

l saf

ety

regu

latio

ns):

• Do

uble

sole

noid

val

ves V

CS K

rom

schr

öder

: dou

ble

sole

noid

val

ves i

nclu

ding

min

gas

pre

ssur

e sw

itch

• Ga

sMul

tiBlo

c Du

ngs G

B-LE

055

Cla

ss B

: com

pact

dou

ble

sole

noid

val

ve w

ith in

tegr

ated

filte

r, re

gula

tor a

nd m

in p

ress

ure

switc

h

avai

labl

e fo

r MAX

GAS

40-

120

• Si

ngle

sole

noid

val

ve B

rahm

a E6

G*SR

P a

nd E

G12*

L fo

r MAX

GAS

40-

120

com

plet

e w

ith m

in g

as p

ress

ure

switc

h•

Sing

le so

leno

id v

alve

Kro

msc

hröd

er V

AS12

5 an

d VA

S240

for M

AX G

AS 1

70-2

50 c

ompl

ete

with

min

gas

pre

ssur

e sw

itch

Gas

trai

n m

atch

ing

tabl

e an

d pr

essu

re d

rop

diag

ram

s for

nat

ural

gas

/LPG

are

ava

ilabl

e in

the

gas t

rain

tech

nica

l doc

umen

tatio

n.

KIT

- ACS

(see

ded

icat

ed p

ages

)•

LPG

KIT

• KI

T W

iela

nd p

lugs

• PI

D m

odul

ating

KIT

and

pro

be•

Antiv

ibra

tion

coup

ling

and

ball

valv

e

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t•

CV: C

ontin

uous

ven

tilati

on v

ersio

n•

HT: H

igh

Tem

pera

ture

ver

sion

• O

EM a

nd sp

ecia

l app

licati

on v

ersio

n on

ly o

n re

ques

t

www.ecoflam-burners.com28

One

stag

e Lo

w N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

- TW

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

MAX

GAS

40

P17

48TC

3142

741

965

3141

885

MBC

65

DLE

1/2"

incl

uded

920

031

2394

4M

B-DL

E 40

3

TL31

4274

29

6531

4188

5M

BC 6

5 DL

E1/

2"in

clud

ed9

200

3123

944

MB-

DLE

403

MAX

GAS

70

P34

70

TC31

4274

3

1036

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed11

3141

886

MBC

120

DLE

1665

3141

885

MBC

65

DLE

1/2"

1820

031

2394

4M

B-DL

E 40

3

TL31

4274

4

1036

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed11

3141

886

MBC

120

DLE

1665

3141

885

MBC

65

DLE

1/2"

1820

031

2394

4M

B-DL

E 40

3

MAX

GAS

105

P49

108

TC31

4274

5

1636

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed18

3141

886

MBC

120

DLE

3465

3141

885

MBC

65

DLE

1/2"

3620

031

2394

4M

B-DL

E 40

3

TL31

4274

6

1636

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed18

3141

886

MBC

120

DLE

3465

3141

885

MBC

65

DLE

1/2"

3620

031

2394

4M

B-DL

E 40

3

MAX

GAS

120

P49

120

TC31

4274

7

1636

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed18

3141

886

MBC

120

DLE

3465

3141

885

MBC

65

DLE

1/2"

3620

031

2394

4M

B-DL

E 40

3

TL31

4274

8

1636

031

2356

0M

B-DL

E 40

53/

4"in

clud

ed18

3141

886

MBC

120

DLE

3465

3141

885

MBC

65

DLE

1/2"

3620

031

2394

4M

B-DL

E 40

3

GAS

BU

RNER

S

MAX

GAS

GAS

TRA

IN -

Expo

rt c

onfig

urati

onde

signa

tion

desc

riptio

nty

pe o

f bur

ner

Øco

deGT

-D1-

GBLE

055-

RP15

-MAX

GAS4

0-12

0M

ultiB

loc

clas

s B -

EN67

6 up

to 7

0 kW

40-1

201/

2"31

4202

7GT

-H1-

E6GS

RP-R

P15-

MAX

GAS4

0-12

0sin

gle

sole

noid

val

ve w

ith m

in g

as p

ress

ure

switc

h40

-120

1/2"

3141

888

GT-H

1-EG

12L-

RP15

-MAX

GAS4

0-12

0sin

gle

sole

noid

val

ve w

ith m

in g

as p

ress

ure

switc

h40

-120

1/2"

3141

887

GT-K

1-VA

S125

-RP2

5-M

AXGA

S170

-250

singl

e so

leno

id v

alve

with

min

gas

pre

ssur

e sw

itch

170-

250

1"31

4281

5GT

-K1-

VAS2

40-R

P40-

MAX

GAS1

70-2

50sin

gle

sole

noid

val

ve w

ith m

in g

as p

ress

ure

switc

h17

0-25

01"

1/2

3142

816

29www.ecoflam-burners.com

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

kit a

dapt

or

MAX

GAS

170

P55

175

TC31

4274

913

360

3123

947

MB-

DLE

410

1"in

clud

ed17

3123

525

MB-

DLE

407

3/4"

2631

2356

0M

B-DL

E 40

53/

4"31

2230

0

TL31

4275

013

360

3123

947

MB-

DLE

410

1"in

clud

ed17

3123

525

MB-

DLE

407

3/4"

2631

2356

0M

B-DL

E 40

53/

4"31

2230

0

MAX

GAS

250

P55

240

TC31

4275

1

15

360

3141

899

MB-

DLE

412

1"1/

4in

clud

ed17

3123

947

MB-

DLE

410

1"26

3123

525

MB-

DLE

407

3/4"

4031

2356

0M

B-DL

E 40

53/

4"31

2230

0

TL31

4275

2

15

360

3141

899

MB-

DLE

412

1"1/

4in

clud

ed17

3123

947

MB-

DLE

410

1"26

3123

525

MB-

DLE

407

3/4"

4031

2356

0M

B-DL

E 40

53/

4"31

2230

0

MAX

GAS

350

P10

035

0

TC31

4228

3

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4228

4

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

MAX

GAS

500

P12

050

0

TC31

4228

9

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4229

0

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

One

stag

e Lo

w N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

- VC

S ga

s tra

in v

ersi

ons -

TW

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MAX

GAS

170

P55

175

TC31

4274

920

500

3141

906

VCS-

125

1"31

4252

1FG

DR 1

"TL

3142

750

2050

031

4190

6VC

S-12

5 1"

3142

521

FGDR

1"

MAX

GAS

250

P

5524

0TC

3142

751

1550

031

4225

1VC

S-24

0 1"

1/2

3142

523

FGDR

1"1

/234

3141

906

VCS-

125

1"31

4252

1FG

DR 1

"

TL31

4275

215

500

3142

251

VCS-

240

1"1/

231

4252

3FG

DR 1

"1/2

3431

4190

6VC

S-12

5 1"

3142

521

FGDR

1"

MAX

GAS

350

P10

035

0TC

3142

283

1850

031

4237

5VC

S-24

0 35

0/50

01"

1/2

3142

523

FGDR

1"1

/254

3142

374

VCS-

125

350/

500

1"31

4252

1FG

DR 1

"

TL31

4228

418

500

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

5431

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

MAX

GAS

500

P12

050

0TC

3142

289

2450

031

4237

5VC

S-24

0 35

0/50

01"

1/2

3142

523

FGDR

1"1

/298

3142

374

VCS-

125

350/

500

1"31

4252

1FG

DR 1

"

TL31

4229

024

500

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

9831

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

www.ecoflam-burners.com30

Two

stag

es L

ow N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

kit a

dapt

or

MAX

GAS

120

PAB

4012

0TC

31

2395

416

360

3123

960

MB-

ZRDL

E 40

53/

4"in

clud

ed

TL31

2395

516

360

3123

960

MB-

ZRDL

E 40

53/

4"in

clud

ed

MAX

GAS

170

PAB

5517

5

TC31

2395

6

13

360

3123

962

MB-

ZRDL

E 41

01"

incl

uded

1731

2396

1M

B-ZR

DLE

407

3/4"

2631

2396

0M

B-ZR

DLE

405

3/4"

3122

300

TL31

2395

7

13

360

3123

962

MB-

ZRDL

E 41

01"

incl

uded

1731

2396

1M

B-ZR

DLE

407

3/4"

2631

2396

0M

B-ZR

DLE

405

3/4"

3122

300

MAX

GAS

250

PAB

5524

0

TC31

2395

8

15

360

3141

901

MB-

ZRDL

E 41

21"

1/4

incl

uded

1731

2396

2M

B-ZR

DLE

410

1"

2631

2396

1M

B-ZR

DLE

407

3/4"

4031

2396

0M

B-ZR

DLE

405

3/4"

3122

300

TL31

2395

9

15

360

3141

901

MB-

ZRDL

E 41

21"

1/4

incl

uded

1731

2396

2M

B-ZR

DLE

410

1"

2631

2396

1M

B-ZR

DLE

407

3/4"

4031

2396

0M

B-ZR

DLE

405

3/4"

3122

300

MAX

GAS

350

PAB

100

350

TC31

4228

5

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4228

6

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

MAX

GAS

500

PAB

120

500

TC31

4229

1

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4229

2

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

31www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l Low

NO

x cl

ass 3

(NO

x <

80 m

g/kW

h)

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

MAX

GAS

350

PR

100

350

TC31

4228

7

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4228

8

17

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

2031

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

3731

4266

5M

B-DL

E 41

0 35

0/50

01"

6031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

MAX

GAS

500

PR

120

500

TC31

4229

3

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

TL31

4229

4

20

360

3142

296

MB-

DLE

415

350/

500

1"1/

2

incl

uded

3531

4229

5M

B-DL

E 41

2 35

0/50

01"

1/4

5531

4266

5M

B-DL

E 41

0 35

0/50

01"

9031

4239

2M

B-DL

E 40

7 35

0/50

03/

4"

Two

stag

es L

ow N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

- VC

S ga

s tra

in v

ersi

ons

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MAX

GAS

350

PAB

100

350

TC31

4228

518

500

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

5431

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

TL31

4228

618

500

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

5431

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

MAX

GAS

500

PAB

120

500

TC31

4229

114

500

3142

376

VCS-

350

350/

500

2"31

4252

4FG

DR 2

"18

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

5431

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

TL31

4229

214

500

3142

376

VCS-

350

350/

500

2"31

4252

4FG

DR 2

"18

3142

375

VCS-

240

350/

500

1"1/

231

4252

3FG

DR 1

"1/2

5431

4237

4VC

S-12

5 35

0/50

01"

3142

521

FGDR

1"

KIT

- ACC

ESSO

RIES

desc

riptio

nTi

ghtn

ess c

ontr

ol

see

acce

ssor

ies p

age

Mod

ulati

on k

itse

e ac

cess

orie

s pag

ePr

obe

see

acce

ssor

ies p

age

LPG

kit

see

acce

ssor

ies p

age

Adap

tor k

it fo

r gas

trai

n se

e ac

cess

orie

s pag

eAd

ditio

nal g

as a

cces

sorie

sse

e ac

cess

orie

s pag

e

www.ecoflam-burners.com32

One

stag

e Lo

w N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

- LP

G v

ersi

ons -

TW

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

LPG

kit

adap

t. ki

tm

inm

ax

blas

t tub

eco

dem

inm

axco

dety

peØ

code

code

MAX

GAS

40

P 17

48TC

3142

741

765

3141

885

MBC

65

DLE

1/2"

3122

301

-TL

3142

742

MAX

GAS

70

P34

70TC

3142

743

1565

3141

885

MBC

65

DLE

1/2"

3122

301

-TL

3142

744

MAX

GAS

105

P

4910

8TC

3142

745

2465

3141

885

MBC

65

DLE

1/2"

3122

301

-TL

3142

746

MAX

GAS

120

P49

120

TC31

4274

724

6531

4188

5M

BC 6

5 DL

E1/

2"31

2230

1-

TL31

4274

8

MAX

GAS

170

P55

175

TC31

4274

923

360

3123

560

MB-

DLE

405

3/4"

3122

302

3122

300

TL31

4275

0

MAX

GAS

250

P

5524

0TC

3142

751

3436

031

2356

0M

B-DL

E 40

53/

4"31

2230

231

2230

0TL

3142

752

MAX

GAS

350

P10

035

0TC

3142

283

3336

031

2239

2M

B-DL

E 40

7 35

0/50

03/

4"31

4243

1-

TL31

4228

4

MAX

GAS

500

P12

050

0TC

3142

289

5236

031

2239

2M

B-DL

E 40

7 35

0/50

03/

4"31

4243

1-

TL31

4229

0

Two

stag

es L

ow N

Ox

clas

s 3 (N

Ox

< 80

mg/

kWh)

- LP

G v

ersi

ons

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

LPG

kit

adap

t. ki

tm

inm

ax

blas

t tub

eco

dem

inm

axco

dety

peØ

code

code

MAX

GAS

120

PAB

4012

0TC

3123

954

1536

031

2396

0M

B-ZR

DLE

405

3/4"

3122

301

-TL

3123

955

MAX

GAS

170

PAB

5517

5TC

3123

956

2336

031

2396

0M

B-ZR

DLE

405

3/4"

3122

302

3122

300

TL31

2395

7

MAX

GAS

250

PAB

5524

0TC

3123

958

3436

031

2396

0M

B-ZR

DLE

405

3/4"

3122

302

3122

300

TL31

2395

9

MAX

GAS

350

PAB

100

350

TC31

4228

533

360

3142

392

MB-

DLE

407

350/

500

3/4"

3142

431

-TL

3142

286

MAX

GAS

500

PAB

120

500

TC31

4229

152

360

3142

392

MB-

DLE

407

350/

500

3/4"

3142

431

-TL

3142

292

Two

stag

es p

rogr

essi

ve m

echa

nica

l Low

NO

x cl

ass 3

(NO

x <

80 m

g/kW

h) -

LPG

ver

sion

s

mod

elou

tput

[kW

]bu

rner

bod

ypr

essu

re [m

bar]

gas t

rain

LPG

kit

adap

t. ki

tm

inm

ax

blas

t tub

eco

dem

inm

axco

dety

peØ

code

code

MAX

GAS

350

PR

100

350

TC31

4228

733

360

3142

392

MB-

DLE

407

350/

500

3/4"

3142

431

-TL

3142

288

MAX

GAS

500

PR

120

500

TC31

4229

352

360

3142

392

MB-

DLE

407

350/

500

3/4"

3142

431

-TL

3142

294

33www.ecoflam-burners.com

GAS

BU

RNER

S

BLU

-

Low

NO

x cl

ass 3

(< 8

0 m

g/kW

h) a

nd c

lass

2 (<

120

mg/

kWh)

BLU

rang

e is

avai

labl

e in

the

follo

win

g ve

rsio

ns a

nd is

del

iver

ed in

a m

odul

ar sy

stem

of b

oxes

:•

PAB:

2 st

ages

• PR

: 2 st

ages

pro

gres

sive

mec

hani

cal

BBCH

: Bur

ner b

ody

with

com

busti

on h

ead

→ T

C sh

ort h

ead

and

TL lo

ng h

ead

SILE

NCE

R: in

clud

ed b

y de

faul

t fro

m B

LU 3

000.

1 an

d op

tiona

l on

smal

ler o

utpu

t KIT

SIL-

...GT

: Gas

trai

n se

para

te →

EN

676

or E

xpor

t con

figur

ation

GTCP

: Con

necti

on p

ipe

betw

een

burn

er a

nd g

as tr

ain

star

ting

from

mod

el 1

700.

1FG

DR: G

as g

over

nor a

nd fi

lter f

or d

oubl

e so

leno

id v

alve

s VCS

Kro

msc

hröd

erFI

LTER

: for

dou

ble

gas v

alve

s VGD

Sie

men

sKI

TTC-

...: T

ight

ness

con

trol

kit

to b

e in

clud

ed o

ver 1

200

kW a

ccor

ding

to E

N67

6KI

TPRE

S-...

: Max

imum

pre

ssur

e sw

itch

KIT

& A

CS c

an b

e ad

ded

acco

rdin

g to

loca

l rul

es in

stal

latio

ns (b

all v

alve

, anti

vibr

ation

cou

plin

g...)

EN67

6 co

nfigu

ratio

n:

• Ga

sMul

tiBlo

c Du

ngs:

com

pact

dou

ble

sole

noid

val

ve w

ith in

tegr

ated

filte

r, re

gula

tor a

nd m

in p

ress

ure

switc

h up

to m

odel

BLU

200

0.1

• Do

uble

sole

noid

val

ves V

CS K

rom

schr

öder

: dou

ble

sole

noid

val

ves i

nclu

ding

min

gas

pre

ssur

e sw

itch

+ se

para

te g

as g

over

nor a

nd fi

lter F

GDR

• Do

uble

gas

val

ves w

ith a

ctua

tors

and

regu

lato

r VGD

Sie

men

s§ + g

as fi

lter

• KI

TTC-

... T

ight

ness

con

trol

dev

ice

mus

t be

incl

uded

ove

r 120

0 kW

acc

ordi

ng to

EN

676

• KI

TPRE

S...

Max

imum

pre

ssur

e sw

itch

as o

ption

or i

n co

mpl

ianc

e w

ith lo

cal s

afet

y re

gula

tions

EXPO

RT c

onfig

urati

on (o

ther

s add

ition

al o

ption

s to

be a

dded

by

inst

alle

r in

com

plia

nce

with

loca

l saf

ety

regu

latio

ns):

• Do

uble

sole

noid

val

ves V

CS K

rom

schr

öder

: dou

ble

sole

noid

val

ves i

nclu

ding

min

gas

pre

ssur

e sw

itch

• Do

uble

gas

val

ves w

ith a

ctua

tors

and

regu

lato

r VGD

Sie

men

KIT

- ACS

(see

ded

icat

ed p

ages

)•

LPG

KIT

up to

Blu

200

0.1

• KI

T W

iela

nd p

lugs

• PI

D m

odul

ating

KIT

and

pro

be•

Antiv

ibra

tion

coup

ling

and

ball

valv

e

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t•

CV: C

ontin

uous

ven

tilati

on v

ersio

n•

OEM

and

spec

ial a

pplic

ation

ver

sion

only

on

requ

est

• KI

TSW

IRL:

Sw

irl sy

stem

for fl

ame

cust

omize

d in

our

FLE

XSH

OP

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

BLU

300

.1 c

hang

e sp

ring

and

dam

ping

(see

pag

. 53)

.

Gas

trai

n m

atch

ing

tabl

e an

d pr

essu

re d

rop

diag

ram

s for

nat

ural

gas

/LPG

are

ava

ilabl

e in

the

gas t

rain

tech

nica

l doc

umen

tatio

n.

www.ecoflam-burners.com34

GAS

BU

RNER

S

BLU

Two

stag

es L

ow N

Ox

(NO

x <

80 m

g/kW

h)

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

700

.1 P

ABLo

w N

Ox

270

700

TC31

2401

2O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

531

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

2401

3O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

531

4202

4VC

S 12

51"

3142

521

FGDR

1"

BLU

100

0.1

PAB

Low

NO

x28

087

5

TC31

4030

3O

PT-

3050

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

6031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

4030

4O

PT-

3050

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

6031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

BLU

120

0.1

PAB

Low

NO

x29

011

00

TC31

4030

9O

PT-

2060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"30

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"65

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

4031

0O

PT-

2060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"30

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"65

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

BLU

150

0.1

PAB

Low

NO

x30

015

50

TC31

4031

2O

PT

3141

842

3070

031

2411

0VG

D 40

.065

2"1/

231

2411

1Fi

lter 2

"1/2

3142

076

4060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

-60

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"13

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4031

3O

PT

3141

842

3070

031

2411

0VG

D 40

.065

2"1/

231

2411

1Fi

lter 2

"1/2

3142

076

4060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

-60

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"13

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

Two

stag

es

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

100

0.1

PAB

245

970

TC31

2401

4O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

5531

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

TL31

2401

5O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

5531

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

35www.ecoflam-burners.com

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

120

0.1

PAB

260

1200

TC31

2401

6O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

2401

7O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

BLU

170

0.1

PAB

342

1770

TC31

4032

6O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

074

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4032

7O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

074

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

BLU

200

0.1

PAB

414

2150

TC31

4033

0O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

074

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4033

1O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

074

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

Two

stag

es p

rogr

essi

ve m

echa

nica

l Low

NO

x cl

ass 3

(NO

x <

80 m

g/kW

h)

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

700

.1 P

RLo

w N

Ox

270

700

TC31

2403

0O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

531

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

2388

6O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

531

4202

4VC

S 12

51"

3142

521

FGDR

1"

BLU

100

0.1

PRLo

w N

Ox

280

875

TC31

4258

7O

PT-

3050

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

6031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"1

/2

TL31

4039

1O

PT-

3050

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

6031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"1

/2

BLU

120

0.1

PRLo

w N

Ox

290

1100

TC31

4039

6O

PT-

2060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"30

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"65

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

4039

7O

PT-

2060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"30

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"65

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

www.ecoflam-burners.com36

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

150

0.1

PRLo

w N

Ox

300

1550

TC31

2410

9O

PT

3141

842

3070

031

2411

0VG

D 40

.065

2"1/

231

2411

1Fi

lter 2

"1/2

3142

076

4060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

-60

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"13

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4040

0O

PT

3141

842

3070

031

2411

0VG

D 40

.065

2"1/

231

2411

1Fi

lter 2

"1/2

3142

076

4060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

-60

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"13

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

Two

stag

es p

rogr

essi

ve m

echa

nica

l

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

100

0.1

PR24

597

0

TC31

2403

1O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

5531

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

TL31

2403

2O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

5531

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

BLU

120

0.1

PR26

012

00

TC31

2403

3O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

2403

4O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

BLU

170

0.1

PR34

217

70

TC31

4040

1O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

074

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4040

2O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

074

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

BLU

200

0.1

PR41

421

50

TC31

4040

3O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

074

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4040

4O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

074

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

37www.ecoflam-burners.com

Two

stag

es -

Mul

tiBlo

c ga

s tra

in

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

BLU

700

.1 P

ABLo

w N

Ox

270

700

TC31

2401

2O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

TL31

2401

3O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

BLU

100

0.1

PAB

Low

NO

x28

087

5

TC31

4030

3O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4031

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

4030

4O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4031

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

BLU

120

0.1

PAB

Low

NO

x29

011

00

TC31

4030

9O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4531

4184

6M

B-DL

E 41

51"

1/2

8531

4184

5M

B-DL

E 41

21"

1/4

TL31

4031

0O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4531

4184

6M

B-DL

E 41

51"

1/2

8531

4184

5M

B-DL

E 41

21"

1/4

BLU

150

0.1

PAB

Low

NO

x30

015

50TC

3140

312

OPT

3142

076

6036

031

4184

7M

B-DL

E 42

02"

incl

uded

7031

4184

6M

B-DL

E 41

51"

1/2

TL31

4031

3O

PT31

4207

660

360

3141

847

MB-

DLE

420

2"in

clud

ed70

3141

846

MB-

DLE

415

1"1/

2

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

BLU

100

0.1

PAB

245

970

TC31

2401

4O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

2401

5O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

BLU

120

0.1

PAB

260

1200

TC31

2401

6O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

TL31

2401

7O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

BLU

170

0.1

PAB

342

1770

TC31

4032

6O

PT31

4207

460

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

TL31

4032

7O

PT31

4207

460

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

BLU

200

0.1

PAB

414

2150

TC31

4033

0O

PT31

4207

475

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

TL31

4033

1O

PT31

4207

475

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

www.ecoflam-burners.com38

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

BLU

100

0.1

PR24

597

0

TC31

2403

1O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

2403

2O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

BLU

120

0.1

PR26

012

00

TC31

2403

3O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

TL31

2403

4O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

BLU

170

0.1

PR34

217

70TC

3140

401

OPT

3142

074

6036

031

4184

7M

B-DL

E 42

02"

incl

uded

8531

4184

6M

B-DL

E 41

51"

1/2

TL31

4040

2O

PT31

4207

460

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

BLU

200

0.1

PR41

421

50TC

3140

403

OPT

3142

074

7536

031

4184

7M

B-DL

E 42

02"

incl

uded

100

3141

846

MB-

DLE

415

1"1/

2

TL31

4040

4O

PT31

4207

475

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

Two

stag

es p

rogr

essi

ve m

echa

nica

l

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

BLU

700

.1 P

RLo

w N

Ox

270

700

TC31

2403

0O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

TL31

2388

6O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

BLU

100

0.1

PRLo

w N

Ox

280

875

TC31

4258

7O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4031

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

4039

1O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4031

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B -D

LE 4

121"

1/4

BLU

120

0.1

PRLo

w N

Ox

290

1100

TC31

4039

6O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4531

4184

6M

B-DL

E 41

51"

1/2

8531

4184

5M

B -D

LE 4

121"

1/4

TL31

4039

7O

PT-

3536

031

4184

7M

B-DL

E 42

02"

incl

uded

4531

4184

6M

B-DL

E 41

51"

1/2

8531

4184

5M

B-DL

E 41

21"

1/4

BLU

150

0.1

PRLo

w N

Ox

300

1550

TC31

2410

9O

PT31

4207

660

360

3141

847

MB-

DLE

420

2"in

clud

ed70

3141

846

MB-

DLE

415

1"1/

2

TL31

4040

0O

PT31

4207

660

360

3141

847

MB-

DLE

420

2"in

clud

ed70

3141

846

MB-

DLE

415

1"1/

2

39www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

300

0.1

PR63

030

00

TC31

4040

5ST

D

314

2069

+31

4207

322

700

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

069

3531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

755

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4040

6ST

D

3142

069+

3142

073

2270

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

3531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

755

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

BLU

400

0.1

PR87

539

00

TC31

4040

7ST

D

3142

069+

3142

073

3070

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

5031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

790

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4040

8ST

D

3142

069+

3142

073

3070

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

5031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

790

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

BLU

500

0.1

PR12

0050

00

TC31

4041

0ST

D

3142

198

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

7531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4207

114

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

6531

4207

525

060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

TL31

4041

1ST

D

3142

198

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

7531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4207

114

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

6531

4207

525

060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"

BLU

600

0.1

PR15

0058

00

TC31

4041

3ST

D

3142

198

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

100

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

071

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4041

4ST

D

3142

198

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

100

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

071

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

BLU

300

0.1

chan

ge sp

ring

and

dam

ping

(see

pag

. 53)

!

www.ecoflam-burners.com40

Vers

ions

from

2 to

25

MW

are

ava

ilabl

e on

requ

est f

or se

lect

ed o

utpu

t to

mat

ch m

ain

boile

rs a

nd in

dust

ry a

pplic

ation

.

BLU

- DU

OBL

OCK

AN

D EL

ECTR

ON

IC B

URN

ERS

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

BLU

700

0.1

PR15

0075

00TC

31

4258

8ST

D

3142

422+

3142

425

60

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

7531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

031

4242

414

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4242

328

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

BLU

800

0.1

PR20

0085

00TC

3142

589

STD

3142

422+

3142

425

85

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

110

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

210

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

423

410

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

BLU

100

00.1

PR

2500

1050

0TC

3142

590

STD

3142

422+

3142

425

115

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

165

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

290

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

423

550

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

BLU

120

00.1

PR

2700

1300

0TC

3142

591

STD

3142

422+

3142

425

175

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

230

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

420

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

BLU

150

00.1

PR

3690

1500

0TC

3142

592

STD

3142

422+

3142

425

150

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

230

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

450

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

BLU

180

00.1

PR

4000

1700

0TC

3142

593

STD

3142

422+

3142

425

210

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

330

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

Two

stag

es p

rogr

essi

ve m

echa

nica

l - N

o si

lenc

er

mod

elou

tput

[kW

]bu

rner

bod

yN

Osil

ence

rm

inm

axbl

ast t

ube

code

BLU

300

0.1

PR63

030

00TC

31

4175

3N

STL

31

4175

4

BLU

400

0.1

PR87

539

00TC

3141

756

NS

TL31

4175

7

BLU

500

0.1

PR12

0050

00TC

31

4175

8N

STL

31

4175

9

BLU

600

0.1

PR15

0058

00TC

3141

761

NS

TL31

4176

2

KIT

- ACC

ESSO

RIES

desc

riptio

n

Tigh

tnes

s con

trol

se

e ac

cess

orie

s pag

e

Mod

ulati

on k

itse

e ac

cess

orie

s pag

e

Prob

ese

e ac

cess

orie

s pag

e

LPG

kit

see

acce

ssor

ies p

age

Adap

tor k

it fo

r gas

trai

n se

e ac

cess

orie

s pag

e

Addi

tiona

l gas

acc

esso

ries

see

acce

ssor

ies p

age

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

BLU

300

0.1

chan

ge sp

ring

and

dam

ping

(see

pag

. 53)

!

41www.ecoflam-burners.com

DUAL

FU

EL B

URN

ERS

(GAS

/LIG

HT O

IL)

MU

LTIC

ALO

R

MU

LTIC

ALO

R is

avai

labl

e in

the

follo

win

g ve

rsio

ns a

nd is

del

iver

ed in

a m

odul

ar sy

stem

of b

oxes

:•

AB: 2

stag

es g

as a

nd li

ght o

il / s

oft st

art l

ight

oil

• PR

-AB:

2 st

ages

pro

gres

sive

mec

hani

cal g

as /

2 st

ages

ligh

t oil

- soft

star

t lig

ht o

il•

PR: 2

stag

es p

rogr

essiv

e m

echa

nica

l gas

- oi

l

BBCH

: Bur

ner b

ody

with

com

busti

on h

ead

→ T

C sh

ort h

ead

and

TL lo

ng h

ead.

Easy

mai

nten

ance

syst

em w

ith h

inge

flan

ge fo

r mod

els 1

500.

1 - 1

800.

1.SI

LEN

CER:

incl

uded

by

defa

ult f

rom

mod

el 3

00.1

and

opti

onal

on

smal

ler o

utpu

t KIT

SIL-

...GT

: Gas

trai

n se

para

te →

EN

676

or E

xpor

t con

figur

ation

GTCP

: Con

necti

on p

ipe

betw

een

burn

er a

nd g

as tr

ain

star

ting

from

mod

el 1

70.1

FG

DR: G

as g

over

nor a

nd fi

lter f

or d

oubl

e so

leno

id v

alve

s VCS

Kro

msc

hröd

erFI

LTER

for d

oubl

e ga

s val

ves V

GD S

iem

ens

KITT

C-...

: Tig

htne

ss c

ontr

ol k

it to

be

incl

uded

ove

r 120

0 kW

acc

ordi

ng to

EN

676

KITP

RES.

..: M

axim

um p

ress

ure

switc

hKI

T &

ACS

can

be

adde

d ac

cord

ing

to lo

cal r

ules

inst

alla

tions

(bal

l val

ve, a

ntivi

brati

on c

oupl

ing.

..)

EN67

6 co

nfigu

ratio

n:

• Ga

sMul

tiBlo

c Du

ngs:

com

pact

dou

ble

sole

noid

val

ve w

ith in

tegr

ated

filte

r, re

gula

tor a

nd m

in p

ress

ure

switc

h up

to m

odel

MU

LTIC

ALO

R 20

0.1

• Do

uble

sole

noid

val

ves V

CS K

rom

schr

öder

: dou

ble

sole

noid

val

ves i

nclu

ding

min

gas

pre

ssur

e sw

itch

+ se

para

te g

as g

over

nor a

nd fi

lter F

GDR

• Do

uble

gas

val

ves w

ith a

ctua

tors

and

regu

lato

r VGD

Sie

men

s§ + g

as fi

lter

• KI

TTC-

... T

ight

ness

con

trol

dev

ice

mus

t be

incl

uded

ove

r 120

0 kW

acc

ordi

ng to

EN

676

• KI

TPRE

S...

Max

imum

pre

ssur

e sw

itch

as o

ption

or i

n co

mpl

ianc

e w

ith lo

cal s

afet

y re

gula

tions

EXPO

RT c

onfig

urati

on (o

ther

s add

ition

al o

ption

s to

be a

dded

by

inst

alle

r in

com

plia

nce

with

loca

l saf

ety

regu

latio

ns):

• Do

uble

sole

noid

val

ves V

CS K

rom

schr

öder

: dou

ble

sole

noid

val

ves i

nclu

ding

min

gas

pre

ssur

e sw

itch

• Do

uble

gas

val

ves w

ith a

ctua

tors

and

regu

lato

r VGD

Sie

men

Stan

dard

ver

sion

runn

ing

on m

anua

l fue

l sel

ectio

n m

ode

and

on re

ques

t kit

for a

utom

atic

fuel

cha

ngeo

ver.

The

auto

mati

c ch

ange

over

syst

em c

an b

e tr

igge

red

by a

gas

pre

ssur

e sw

itch

or b

y a

timer

.

KIT

- ACS

(see

ded

icat

ed p

ages

)•

LPG

KIT

up to

MU

LTIC

ALO

R 20

0.1

• KI

T au

tom

atic

fuel

cha

ngeo

ver

• PI

D m

odul

ating

KIT

and

pro

be•

KIT

Wie

land

plu

gs•

Antiv

ibra

tion

coup

ling

and

ball

valv

e

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t•

CV: C

ontin

uous

ven

tilati

on v

ersio

n•

OEM

and

spec

ial a

pplic

ation

ver

sion

only

on

requ

est

• KI

TSW

IRL:

Sw

irl sy

stem

for fl

ame

cust

omize

d in

our

FLE

XSH

OP

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar.

From

MU

LTIC

ALO

R 30

0.1

chan

ge sp

ring

and

dam

ping

(see

pag

. 53)

.

Gas

trai

n m

atch

ing

tabl

e an

d pr

essu

re d

rop

diag

ram

s for

nat

ural

gas

/LPG

are

ava

ilabl

e in

the

gas t

rain

tech

nica

l doc

umen

tatio

n.

www.ecoflam-burners.com42

DUAL

FU

EL B

URN

ERS

(GAS

/LIG

HT O

IL)

MU

LTIC

ALO

RTw

o st

ages

gas

/ T

wo

stag

es li

ght o

il

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIC

ALO

R 45

190

500

TC31

4042

9-

-17

500

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

9031

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

4042

8-

-17

500

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

9031

4202

4VC

S 12

51"

3142

521

FGDR

1"

MU

LTIC

ALO

R 70

250

700

TC31

4043

1O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

4043

0O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

MU

LTIC

ALO

R 10

030

010

00

TC31

4043

3O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

4031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

TL31

4043

2O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

4031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

MU

LTIC

ALO

R 14

040

013

00

TC31

4043

9O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

4043

8O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

MU

LTIC

ALO

R 17

0.1

342

1770

TC31

4262

8O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

075

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4262

9O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

075

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

MU

LTIC

ALO

R 20

0.1

414

2150

TC31

4263

0O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

075

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4263

1O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

075

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

43www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es li

ght o

il

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

pres

sure

[mba

r]ga

s tra

inga

s gov

erno

r and

filte

r

min

max

blas

t tub

eco

deco

dem

inm

axco

dety

peØ

code

type

MU

LTIC

ALO

R70

PR-

AB19

070

0

TC31

4263

2O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

TL31

4263

3O

PT-

1550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

3031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/217

031

4202

4VC

S 12

51"

3142

521

FGDR

1"

MU

LTIC

ALO

R10

0 PR

-AB

200

1000

TC31

4263

4O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

4031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

TL31

4263

5O

PT-

2550

031

4186

2VC

S 35

02"

3142

524

FGDR

2"

4031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/216

531

4202

4VC

S 12

51"

3142

523

FGDR

1"1

/2

MU

LTIC

ALO

R14

0 PR

-AB

250

1300

TC31

4263

6O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

TL31

4263

7O

PT-

2560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"35

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"80

3142

025

VCS

240

1"1/

231

4252

3FG

DR 1

"1/2

MU

LTIC

ALO

R17

0.1

PR-A

B34

217

70

TC31

4263

8O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

075

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4263

9O

PT

3142

069

2070

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

075

4560

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"65

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"15

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

MU

LTIC

ALO

R20

0.1

PR-A

B41

421

50

TC31

4264

0O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

075

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

TL31

4264

1O

PT

3142

069

2370

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

735

3124

110

VGD

40.0

652"

1/2

3124

111

Filte

r DN

65

3142

075

6060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

"90

500

3141

862

VCS

350

2"31

4252

4FG

DR 2

"22

031

4202

5VC

S 24

01"

1/2

3142

523

FGDR

1"1

/2

www.ecoflam-burners.com44

Two

stag

es g

as /

Tw

o st

ages

ligh

t oil

- Mul

tiBlo

c ga

s tra

in

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

MU

LTIC

ALO

R 45

190

500

TC31

4042

9O

PT-

15

360

3141

846

MB-

DLE

415

1"1/

2

incl

uded

3031

4184

5M

B-DL

E 41

21"

1/4

5031

4202

2M

B-DL

E 41

01"

8531

2352

5M

B-DL

E 40

73/

4"

TL31

4042

8O

PT-

15

360

3141

846

MB-

DLE

415

1"1/

2

incl

uded

3031

4184

5M

B-DL

E 41

21"

1/4

5031

4202

2M

B-DL

E 41

01"

8531

2352

5M

B-DL

E 40

73/

4"

MU

LTIC

ALO

R 70

250

700

TC31

4043

1O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

TL31

4043

0O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

MU

LTIC

ALO

R 10

030

010

00

TC31

4043

3O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

4043

2O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

MU

LTIC

ALO

R 14

040

013

00

TC31

4043

9O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

TL31

4043

8O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

MU

LTIC

ALO

R 17

0.1

342

1770

TC31

4262

8O

PT31

4207

560

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

TL31

4262

9O

PT31

4207

560

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

MU

LTIC

ALO

R 20

0.1

414

2150

TC31

4263

0O

PT31

4207

575

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

TL31

4263

1O

PT31

4207

575

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

45www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es li

ght o

il - M

ultiB

loc

gas t

rain

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

code

type

Ø

MU

LTIC

ALO

R70

PR-

AB19

070

0

TC31

4263

2O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

TL31

4263

3O

PT-

1736

031

4184

7M

B-DL

E 42

02"

incl

uded

2531

4184

6M

B-DL

E 41

51"

1/2

7531

4202

2M

B-DL

E 41

01"

MU

LTIC

ALO

R10

0 PR

-AB

200

1000

TC31

4263

4O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

TL31

4263

5O

PT-

2736

031

4184

7M

B-DL

E 42

02"

incl

uded

3531

4184

6M

B-DL

E 41

51"

1/2

7531

4184

5M

B-DL

E 41

21"

1/4

MU

LTIC

ALO

R14

0 PR

-AB

250

1300

TC31

4263

6O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

TL31

4263

7O

PT-

4036

031

4184

7M

B-DL

E 42

02"

incl

uded

5031

4184

6M

B-DL

E 41

51"

1/2

100

3141

845

MB-

DLE

412

1"1/

4

MU

LTIC

ALO

R17

0.1

PR-A

B34

217

70TC

3142

638

OPT

3142

075

6036

031

4184

7M

B-DL

E 42

02"

incl

uded

8531

4184

6M

B-DL

E 41

51"

1/2

TL31

4263

9O

PT31

4207

560

360

3141

847

MB-

DLE

420

2"in

clud

ed85

3141

846

MB-

DLE

415

1"1/

2

MU

LTIC

ALO

R20

0.1

PR-A

B41

421

50TC

3142

640

OPT

3142

075

7536

031

4184

7M

B-DL

E 42

02"

incl

uded

100

3141

846

MB-

DLE

415

1"1/

2

TL31

4264

1O

PT31

4207

575

360

3141

847

MB-

DLE

420

2"in

clud

ed10

031

4184

6M

B-DL

E 41

51"

1/2

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es p

rogr

essi

ve m

echa

nica

l lig

ht o

il - O

nly

body

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rm

inm

axbl

ast t

ube

code

MU

LTIC

ALO

R 70

PR

250

700

TLon

requ

est

OPT

MU

LTIC

ALO

R 10

0 PR

300

1000

TLon

requ

est

OPT

MU

LTIC

ALO

R 14

0 PR

400

1300

TLon

requ

est

OPT

MU

LTIC

ALO

R 17

0.1

PR34

217

70TL

on re

ques

tO

PTM

ULT

ICAL

OR

200.

1 PR

414

2150

TLon

requ

est

OPT

www.ecoflam-burners.com46

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es p

rogr

essi

ve m

echa

nica

l lig

ht o

il

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIC

ALO

R30

0.1

PR63

030

00

TC31

4264

2ST

D

3142

069+

3142

073

2270

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

3531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

755

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4264

3ST

D

3142

069+

3142

073

2270

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

3531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

755

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

MU

LTIC

ALO

R40

0.1

PR87

539

00

TC31

4264

4ST

D

3142

069+

3142

073

3070

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

5031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

790

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4264

5ST

D

3142

069+

3142

073

3070

031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

069

5031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4219

790

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

MU

LTIC

ALO

R50

0.1

PR12

0050

00

TC31

4264

6ST

D

3142

198

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

7531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4207

014

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

6531

4207

525

060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

''

TL31

4264

7ST

D

3142

198

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

7531

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4207

114

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

6531

4207

525

060

031

2386

0VG

D 20

.503

2"31

2138

4Fi

lter 2

''

MU

LTIC

ALO

R60

0.1

PR15

0058

00

TC31

4264

8ST

D

3142

198

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

100

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

071

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

TL31

4264

9ST

D

3142

198

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

070+

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

3142

070

100

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

071

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3142

075

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIC

ALO

R 30

0.1

chan

ge sp

ring

and

dam

ping

(see

pag

. 53)

!

47www.ecoflam-burners.com

Vers

ions

from

2 to

25

MW

are

ava

ilabl

e on

requ

est f

or se

lect

ed o

utpu

t to

mat

ch m

ain

boile

rs a

nd in

dust

ry a

pplic

ation

.

MU

LTIC

ALO

R - D

UO

BLO

CK A

ND

ELEC

TRO

NIC

BU

RNER

S

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIC

ALO

R70

0.1

PR15

0075

00TC

3142

650

STD

3142

422+

31

4242

560

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

7531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

031

4242

414

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

8031

4242

328

031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

MU

LTIC

ALO

R80

0.1

PR20

0085

00TC

3142

651

STD

3142

422+

31

4242

585

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

110

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

210

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

423

410

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

MU

LTIC

ALO

R 10

00.1

PR

2500

1050

0TC

3142

652

STD

3142

422+

31

4242

511

5

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

422

165

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

290

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

423

550

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

MU

LTIC

ALO

R 12

00.1

PR

2700

1300

0TC

3142

653

STD

3142

422+

31

4242

517

570

031

4266

6VG

D 40

.125

DN12

531

4220

6Fi

lter D

N12

5

3142

422

230

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

420

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

MU

LTIC

ALO

R 15

00.1

PR

3690

1500

0TC

3142

654

STD

3142

422+

31

4242

515

070

031

4266

6VG

D 40

.125

DN12

531

4220

6Fi

lter D

N12

5

3142

422

230

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

3142

424

450

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

MU

LTIC

ALO

R 18

00.1

PR

4000

1700

0TC

3142

655

STD

3142

422+

31

4242

521

070

031

4266

6VG

D 40

.125

DN12

531

4220

6Fi

lter D

N12

5

3142

422

330

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

KIT

- ACC

ESSO

RIES de

scrip

tion

Sile

ncer

see

acce

ssor

ies p

age

Tigh

tnes

s con

trol

see

acce

ssor

ies p

age

Mod

ulati

on k

itse

e ac

cess

orie

s pag

ePr

obe

see

acce

ssor

ies p

age

LPG

kit

see

acce

ssor

ies p

age

Addi

tiona

l gas

acc

esso

ries

see

acce

ssor

ies p

age

Auto

mati

c fu

el c

hang

eove

r kit

see

acce

ssor

ies p

age

Oil

pum

ping

uni

tse

e ac

cess

orie

s pag

e

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIC

ALO

R 30

0.1

chan

ge sp

ring

and

dam

ping

(see

pag

. 53)

!

www.ecoflam-burners.com48

DUAL

FU

EL B

URN

ERS

(GAS

/HEA

VY O

IL)

MU

LTIF

LAM

-

Max

vis

c. 5

0° -

100°

E at

50°

C

MU

LTIF

LAM

rang

e is

avai

labl

e in

the

follo

win

g ve

rsio

ns a

nd is

del

iver

ed in

a

mod

ular

syst

em o

f box

es:

• PA

B: 2

stag

es g

as a

nd h

eavy

oil

/ soft

star

t hea

vy o

il•

PR: 2

stag

es p

rogr

essiv

e m

echa

nica

l gas

- he

avy

oil

BBCH

: Bur

ner b

ody

with

com

busti

on h

ead

→ T

C sh

ort h

ead

and

TL lo

ng h

ead

in D

ver

sion

for h

eavy

oi

l with

max

visc

50°

E at

50°

C. E

lect

rical

pre

-hea

ter p

reas

sem

bled

into

the

burn

er b

ody.

Al

l bur

ners

bod

y in

clud

e sil

ence

r and

are

del

iver

ed w

ith sl

idin

g ba

r sys

tem

up

to m

odel

120

0.1

and

with

hin

ge fl

ange

for m

odel

s 200

.1 a

nd 1

500.

1 - 1

800.

1.SI

LEN

CER:

incl

uded

by

defa

ult f

rom

mod

el 3

00.1

and

opti

onal

on

smal

ler o

utpu

t KIT

SIL-

...GT

: Gas

trai

n se

para

te →

EN

676

or E

xpor

t con

figur

ation

GTCP

: Con

necti

on p

ipe

betw

een

burn

er a

nd g

as tr

ain

star

ting

from

mod

el 1

70.1

FG

DR: G

as g

over

nor a

nd fi

lter f

or d

oubl

e so

leno

id v

alve

s VCS

Kro

msc

hröd

erFI

LTER

for d

oubl

e ga

s val

ves V

GD S

iem

ens

KITT

C-...

: Tig

htne

ss c

ontr

ol k

it to

be

incl

uded

ove

r 120

0 kW

acc

ordi

ng to

EN

676

KITP

RES.

..: M

axim

um p

ress

ure

switc

hKI

T &

ACS

can

be

adde

d ac

cord

ing

to lo

cal r

ules

inst

alla

tions

(bal

l val

ve, a

ntivi

brati

on c

oupl

ing.

..)

EN67

6 co

nfigu

ratio

n:•

Doub

le g

as v

alve

s with

act

uato

rs a

nd re

gula

tor V

GD S

iem

ens§ +

gas

filte

r•

KITT

C-...

Tig

htne

ss c

ontr

ol d

evic

e m

ust b

e in

clud

ed o

ver 1

200

kW a

ccor

ding

to E

N67

6•

KITP

RES.

.. M

axim

um p

ress

ure

switc

h as

opti

on o

r in

com

plia

nce

with

loca

l saf

ety

regu

latio

ns

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIF

LAM

300

.1 c

hang

e sp

ring

and

dam

ping

(see

pag

. 53)

.

Gas

trai

n m

atch

ing

tabl

e an

d pr

essu

re d

rop

diag

ram

s for

nat

ural

gas

/LPG

are

ava

ilabl

e in

the

gas t

rain

tech

nica

l doc

umen

tatio

n.

Stan

dard

ver

sion

runn

ing

on m

anua

l fue

l sel

ectio

n m

ode

and

on re

ques

t kit

for a

utom

atic

fuel

cha

ngeo

ver.

The

auto

mati

c ch

ange

over

syst

em c

an b

e tr

igge

red

by a

gas

pre

ssur

e sw

itch

or b

y a

timer

.

KIT

- ACS

(see

ded

icat

ed p

ages

)•

KIT

auto

mati

c fu

el c

hang

eove

r•

PID

mod

ulati

ng K

IT a

nd p

robe

• KI

T W

iela

nd p

lugs

• An

tivib

ratio

n co

uplin

g an

d ba

ll va

lve

Avai

labl

e co

nfigu

ratio

ns o

n re

ques

t:•

CV: C

ontin

uous

ven

tilati

on v

ersio

n•

OEM

and

spec

ial a

pplic

ation

ver

sion

only

on

requ

est

• KI

TSW

IRL:

Sw

irl sy

stem

for fl

ame

cust

omize

d in

our

FLE

XSH

OP

49www.ecoflam-burners.com

DUAL

FU

EL B

URN

ERS

(GAS

/HEA

VY O

IL)

MU

LTIF

LAM

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es p

rogr

essi

ve m

echa

nica

l hea

vy o

il - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIF

LAM

300.

1 PR

630

3000

TC31

4265

6ST

D

3142

073

22

700

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

-35

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

5531

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4265

7ST

D

3142

073

22

700

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

-35

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

5531

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

MU

LTIF

LAM

400.

1 PR

875

3900

TC31

4265

8ST

D

3142

073

30

700

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

-50

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

9031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4265

9ST

D

3142

073

30

700

3141

869

VGD

40.1

00DN

100

3142

205

Filte

r DN

100

-50

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

9031

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

170

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

Two

stag

es g

as /

Tw

o st

ages

hea

vy o

il - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIF

LAM

200.

141

421

50

TC31

4266

9ST

D

-35

700

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

5531

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

TL31

4267

0ST

D

-35

700

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

5531

2411

0VG

D 40

.065

DN65

3124

111

Filte

r DN

65

3143

080

100

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2"

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIF

LAM

300

.1 c

hang

e sp

ring

and

dam

ping

(see

pag

. 53)

!

www.ecoflam-burners.com50

KIT

- ACC

ESSO

RIES de

scrip

tion

Sile

ncer

see

acce

ssor

ies p

age

Tigh

tnes

s con

trol

see

acce

ssor

ies p

age

Mod

ulati

on k

itse

e ac

cess

orie

s pag

ePr

obe

see

acce

ssor

ies p

age

LPG

kit

see

acce

ssor

ies p

age

Addi

tiona

l gas

acc

esso

ries

see

acce

ssor

ies p

age

Auto

mati

c fu

el c

hang

eove

r kit

see

acce

ssor

ies p

age

Oil

heati

ng p

umpi

ng u

nit

see

acce

ssor

ies p

age

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rco

nnec

tion

pipe

cod

epr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor a

nd fi

lter

min

max

blas

t tub

eco

dem

inm

axco

dety

peØ

code

type

MU

LTIF

LAM

500.

1 PR

1200

5000

TC31

4266

0ST

D

3143

105

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

-75

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

140

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3143

080

250

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

TL31

4266

1ST

D

3143

105

35

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

073

4531

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

-75

3142

026

VGD

40.0

80DN

8031

4208

8Fi

lter D

N80

3142

935

140

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3143

080

250

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

MU

LTIF

LAM

600.

1 PR

1500

5800

TC31

4266

2ST

D

3143

105

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

-10

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

935

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3143

080

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

TL31

4266

3ST

D

3143

105

50

700

3142

666

VGD

40.1

25DN

125

3142

206

Filte

r DN

125

3142

073

6031

4186

9VG

D 40

.100

DN10

031

4220

5Fi

lter D

N10

0

-10

031

4202

6VG

D 40

.080

DN80

3142

088

Filte

r DN

80

3142

935

180

3124

110

VGD

40.0

65DN

6531

2411

1Fi

lter D

N65

3143

080

340

600

3123

860

VGD

20.5

032"

3121

384

Filte

r 2''

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIF

LAM

300

.1 c

hang

e sp

ring

and

dam

ping

(see

pag

. 53)

!

51www.ecoflam-burners.com

Two

stag

es p

rogr

essi

ve m

echa

nica

l gas

/ T

wo

stag

es p

rogr

essi

ve m

echa

nica

l hea

vy o

il - 5

0°E

fuel

vis

cosi

ty a

t 50°

C

mod

elou

tput

[kW

]bu

rner

bod

ysil

ence

rpr

essu

re [m

bar]

gas t

rain

(§)

gas g

over

nor

and

filte

rm

inm

axbl

ast t

ube

code

min

max

type

Ø

MU

LTIF

LAM

700

.1 P

R15

0075

00TC

-ST

D

60

700

VGD

40.1

25DN

125

Filte

r DN

125

75VG

D 40

.100

DN10

0Fi

lter D

N10

0

140

VGD

40.0

80DN

80Fi

lter D

N80

280

VGD

40.0

65DN

65Fi

lter D

N65

MU

LTIF

LAM

800

.1 P

R20

0085

00TC

-ST

D

85

700

VGD

40.1

25DN

125

Filte

r DN

125

110

VGD

40.1

00DN

100

Filte

r DN

100

210

VGD

40.0

80DN

80Fi

lter D

N80

410

VGD

40.0

65DN

65Fi

lter D

N65

MU

LTIF

LAM

100

0.1

PR25

0010

500

TC-

STD

115

700

VGD

40.1

25DN

125

Filte

r DN

125

165

VGD

40.1

00DN

100

Filte

r DN

100

290

VGD

40.0

80DN

80Fi

lter D

N80

550

VGD

40.0

65DN

65Fi

lter D

N65

MU

LTIF

LAM

120

0.1

PR27

0013

000

TC-

STD

160

700

VGD

40.1

50DN

150

Filte

r DN

150

175

VGD

40.1

25DN

125

Filte

r DN

125

230

VGD

40.1

00DN

100

Filte

r DN

100

420

VGD

40.0

80DN

80Fi

lter D

N80

MU

LTIF

LAM

150

0.1

PR36

9015

000

TC-

STD

125

700

VGD

40.1

50DN

150

Filte

r DN

150

150

VGD

40.1

25DN

125

Filte

r DN

125

230

VGD

40.1

00DN

100

Filte

r DN

100

450

VGD

40.0

80DN

80Fi

lter D

N80

MU

LTIF

LAM

180

0.1

PR40

0017

000

TC-

STD

175

700

VGD

40.1

50DN

150

Filte

r DN

150

210

VGD

40.1

25DN

125

Filte

r DN

125

330

VGD

40.1

00DN

100

Filte

r DN

100

Vers

ions

from

2 to

25

MW

are

ava

ilabl

e on

requ

est f

or se

lect

ed o

utpu

t to

mat

ch m

ain

boile

rs a

nd in

dust

ry a

pplic

ation

.

MU

LTIF

LAM

- DU

OBL

OCK

AN

D EL

ECTR

ON

IC B

URN

ERS

§ VG

D Si

emen

s: d

efau

lt bl

ank

sprin

g, h

ead

pres

sure

0...

22 m

bar;

from

MU

LTIF

LAM

300

.1 c

hang

e sp

ring

and

dam

ping

(see

pag

. 53)

!

www.ecoflam-burners.com52

Confi

gura

tion

MB-

DLE

Mul

tiBlo

c Du

ngs M

AX G

AS 4

0-25

Code

EN67

6

Mul

tiBlo

c Du

ngs:

com

pact

dou

ble

sole

noid

val

ve w

ith

inte

grat

ed fi

lter,

regu

lato

r and

min

pre

ssur

e sw

itch.

WAR

NIN

G:

EN67

6 co

mpu

lsory

kit

and

acce

ssor

ies i

n or

der t

o co

mpl

y to

the

safe

ty re

gula

tions

. Add

ition

al a

cces

sorie

s and

kits

sh

all b

e in

stal

led

by th

e in

stal

ler i

n ac

cord

ance

to th

e lo

cal s

afet

y re

gula

tions

and

cod

es o

f pra

ctise

.

GT-D

1-M

BC65

DLE-

RP15

-MAX

GAS4

0-12

0RP

15

- 1/2

"31

4188

5GT

-D1-

MBC

120D

LE-R

P20-

MAX

GAS4

0-12

0RP

20

- 3/4

"31

4188

6GT

-D1-

MBD

LE40

3-RP

15-M

AXGA

S40-

120

RP 1

5 - 1

/2"

3123

944

GT-D

1-M

BDLE

405-

RP20

-MAX

GAS4

0-12

0RP

20

- 3/4

"31

2356

0GT

-D1-

MBD

LE40

7-RP

20-M

AXGA

S170

-250

RP 2

0 - 3

/4"

3123

525

GT-D

1-M

BDLE

410-

RP25

-MAX

GAS1

70-2

50RP

25

- 1"

3123

947

GT-D

1-M

BDLE

412-

RP32

-MAX

GAS1

70-2

50RP

32

- 1"1

/431

4189

9GT

-D1-

MBD

LE41

5-RP

40-M

AXGA

S170

-250

RP 4

0 - 1

"1/2

3123

969

MB-

ZRDL

E M

ultiB

loc

Dung

s MAX

GAS

40-

250

ØCo

deGT

-D2-

MBZ

RDLE

405-

RP20

-MAX

GAS4

0-12

0RP

20

- 3/4

"31

2396

0GT

-D2-

MBZ

RDLE

407-

RP20

-MAX

GAS1

70-2

50RP

20

- 3/4

"31

2396

1GT

-D2-

MBZ

RDLE

410-

RP25

-MAX

GAS1

70-2

50RP

25

- 1"

3123

962

GT-D

2-M

BZRD

LE41

2-RP

32-M

AXGA

S170

-250

RP 3

2 - 1

"1/4

3141

901

GT-D

2-M

BZRD

LE41

5-RP

40-M

AXGA

S170

-250

RP 4

0 - 1

"1/2

3123

879

MB-

DLE

Mul

tiBlo

c Du

ngs M

AX G

AS 3

50-5

00Ø

Code

GT-D

2-M

BDLE

407-

RP20

-MAX

GAS3

50-5

00RP

20

- 3/4

"31

4239

2GT

-D2-

MBD

LE41

0-RP

25-M

AXGA

S350

-500

RP 2

5 - 1

"31

4266

5GT

-D2-

MBD

LE41

2-RP

32-M

AXGA

S350

-500

RP 3

2 - 1

"1/4

3142

295

GT-D

2-M

BDLE

415-

RP40

-MAX

GAS3

50-5

00RP

40

- 1"1

/231

4229

6Co

nfigu

ratio

nVC

S Kr

omsc

hröd

er M

AX G

AS 1

70-2

50Ø

Code

Expo

rtEN

676

+ FG

DR

Doub

le so

leno

id v

alve

s VCS

Kro

msc

hröd

er

and

min

pre

ssur

e sw

itch

+ AC

S ga

s gov

erno

r & fi

lter

GT-K

1-VC

S125

-RP2

5-M

AXGA

S170

-250

RP 2

5 - 1

"31

4190

6GT

-K1-

VCS2

40-R

P40-

MAX

GAS1

70-2

50RP

40

- 1"1

/231

4225

1VC

S Kr

omsc

hröd

er M

AX G

AS 3

50-5

00Ø

Code

GT-K

2-VC

S125

-RP2

5-M

AXGA

S350

-500

/MU

LTI

RP 2

5 - 1

"31

4237

4GT

-K2-

VCS2

40-R

P40-

MAX

GAS3

50-5

00/M

ULT

IRP

40

- 1"1

/231

4237

5GT

-K2-

VCS3

50-R

P50-

MAX

GAS3

50-5

00/M

ULT

IRP

50

- 2"

3142

376

Confi

gura

tion

Expo

rt g

as tr

ains

MAX

GAS

40-

250

ØCo

de

Onl

y Ex

port

(not

EN

676)

GT-D

1-GB

LE05

5-RP

15-M

AXGA

S40-

120

RP 1

5 - 1

/2"

3142

027

GT-B

1-E6

GSRP

-RP1

5-M

AXGA

S40-

120

RP 1

5 - 1

/2"

3141

888

GT-B

1-EG

12L-

RP15

-MAX

GAS4

0-12

0RP

15

- 1/2

"31

4188

7GT

-K1-

VAS1

25-R

P25-

MAX

GAS1

70-2

50RP

25

- 1"

3142

815

GT-K

1-VA

S240

-RP4

0-M

AXGA

S170

-250

RP 4

0 - 1

"1/2

3142

816

GAS

TRA

IN: M

AX G

AS

53www.ecoflam-burners.com

GAS

TRA

IN -

GTCP

: BLU

- M

ULT

ICAL

OR

- MU

LTIF

LAM

GT C

onfig

urati

onDe

sign

ation

MB-

DLE

Mul

tiBlo

c Du

ngs

ØCo

de

EN67

6M

ultiB

loc

Dung

s: c

ompa

ct d

oubl

e so

leno

id v

alve

w

ith in

tegr

ated

filte

r, re

gula

tor a

nd m

in p

ress

ure

switc

h.

GT-D

2-M

BDLE

407-

RP20

-BLU

/MU

LTI

RP 2

0 - 3

/4"

3141

843

GT-D

2-M

BDLE

410-

RP25

-BLU

/MU

LTI

RP 2

5 - 1

"31

4202

2GT

-D2-

MBD

LE41

2-RP

32-B

LU/M

ULT

IRP

32

- 1"1

/431

4184

5GT

-D2-

MBD

LE41

5-RP

40-B

LU/M

ULT

IRP

40

- 1"1

/231

4184

6GT

-D2-

MBD

LE42

0-RP

50-B

LU/M

ULT

IRP

50

- 2"

3141

847

GT C

onfig

urati

onDe

sign

ation

VCS

Kro

msc

hröd

er

ØCo

deEx

port

/ EN

676

+ FG

DRDo

uble

sole

noid

val

ves V

CS K

rom

schr

öder

and

m

in p

ress

ure

switc

h +

ACS

gas g

over

nor &

filte

r

GT-K

2-VC

S125

-RP2

5-BL

U/M

ULT

IRP

25

- 1"

3142

024

GT-K

2-VC

S240

-RP4

0-BL

U/M

ULT

IRP

40

- 1"1

/231

4202

5GT

-K2-

VCS3

50-R

P50-

BLU

/MU

LTI

RP 5

0 - 2

"31

4186

2GT

Con

figur

ation

Desi

gnati

on V

GD

Siem

ens

ØCo

de

Expo

rt /

EN67

6 +

FGDR

Doub

le g

as v

alve

s with

act

uato

rs a

nd re

gula

tor

VGD

Siem

ens a

nd m

in p

ress

ure

switc

h +

ACS

gas

filte

r.De

faul

t bla

nk sp

ring:

hea

d pr

essu

re 0

...22

mba

r

WAR

NIN

G:

from

BLU

300

0.1

- MU

LTIC

ALO

R 30

0.1

-M

ULT

IFLA

M 3

00.1

cha

nge

sprin

g an

d da

mpi

ng

GT-S

2-VG

D20-

RP50

-BLU

/MU

LTI

Gas t

rain

sin

clud

e A

CTUA

TORS

RP 5

0 - 2

"31

2386

0GT

-S2-

VGD4

0-DN

65-B

LU/M

ULT

IDN

65

- 2" 1

/231

2411

0GT

-S2-

VGD4

0-DN

80-B

LU/M

ULT

IDN

80

- 3"

3142

026

GT-S

2-VG

D40-

DN10

0-BL

U/M

ULT

IDN

100

- 4"

3141

869

GT-S

2-VG

D40-

DN10

0+VD

K-BL

U/M

ULT

IDN

100

- 4"

+ V

DK31

4187

1GT

-S2-

VGD4

0-DN

125-

BLU

/MU

LTI

DN 1

25 -

5"31

4266

6GT

-S2-

VGD4

0-DN

125+

VDK-

BLU

/MU

LTI

DN 1

25 -

5" +

VDK

3141

872

Yello

w se

tpoi

nt sp

ring

for S

KP25

...He

ad p

ress

ure:

15.

..120

mba

r31

4220

4Da

mpi

ng th

rott

le fo

r SKP

25...

3142

207

GAS

TRA

IN C

ON

NEC

TIO

N P

IPE

Desc

riptio

nDe

sign

ation

Code

GTCP

RP5

0-DN

65 p

latfo

rm 2

60GT

CP-R

P50-

DN65

-260

3141

842

GTCP

RP5

0 pl

atfor

m 2

80GT

CP-R

P50-

280

3142

074

GTCP

RP5

0 pl

atfor

m 3

20/3

80GT

CP-R

P50-

320/

380

3142

075

GTCP

RP5

0 BL

U 1

500

with

MB4

15-4

20GT

CP-R

P50-

BLU

1500

-MB4

15-4

2031

4207

6GT

CP R

P50

adap

tor M

ultifl

amGT

CP-R

P50-

ADAP

TOR-

MU

LTIF

LAM

3143

080

GTCP

DN

65 p

latfo

rm 2

60/2

80/3

20

GTCP

-DN

65-2

60/2

80/3

2031

4219

7GT

CP D

N80

pla

tform

260

/280

/320

*GT

CP-D

N80

-260

/280

/320

3142

069

GTCP

DN

65 p

latfo

rm 3

80GT

CP-D

N65

-380

3142

071

GTCP

DN

80 p

latfo

rm 3

80 *

GTCP

-DN

80-3

8031

4207

0GT

CP re

duce

r fro

m D

N80

to D

N65

Mul

tiflam

GTCP

-RED

UCE

RDN

80TO

DN65

3142

935

GTCP

redu

cer f

rom

DN

100

to D

N80

pla

tform

320

/380

(*)

GTCP

-RED

UCE

RDN

100T

ODN

8031

4207

3GT

CP re

duce

r fro

m D

N12

5 to

DN

80 p

latfo

rm 3

20/3

80 (*

)GT

CP-R

EDU

CERD

N12

5TO

DN80

3143

105

GTCP

DN

125

platf

orm

380

GTCP

-DN

125-

380

3142

198

GTCP

DN

65 p

latfo

rm 6

30GT

CP-D

N65

-630

3142

423

GTCP

DN

80 p

latfo

rm 6

30/7

10GT

CP-D

N80

-630

/710

3142

424

GTCP

DN

100

platf

orm

630

/710

GTCP

-DN

100-

630/

710

3142

422

GTCP

DN

125

platf

orm

630

/710

Both

cod

es n

eces

sary

for

gas t

rain

DN

125

GTCP

-DN

125-

630/

710

3142

422

GTCP

redu

cer f

rom

DN

125

to D

N10

0GT

CP-R

EDU

CERD

N12

5TO

DN10

031

4242

5

WAR

NIN

G:

From

BLU

170

0.1

- MU

LTIC

ALO

R 17

0.1

- M

ULT

IFLA

M 2

00.1

, in

orde

r to

fit th

e ga

s tra

in,

the

corr

espo

ndin

g co

nnec

tion

pipe

mus

t be

orde

red

(GTC

P siz

e an

d fitti

ng d

epen

d on

the

burn

er a

nd th

e ga

s tra

in se

lect

ed)

SPRI

NG

DAM

PIN

G TH

ROTT

LE

www.ecoflam-burners.com54

ACCE

SSO

RIES

FO

R G

AS

GAS

GO

VERN

OR

and

FILT

ER F

GDR

Max

gas

pre

ssur

eCo

deRP

15

- 1/2

" *50

0 m

bar

3142

519

RP 2

0 - 3

/4" *

500

mba

r31

4252

0RP

25

- 1" *

500

mba

r31

4252

1RP

32

- 1" 1

/4 *

500

mba

r31

4252

2RP

40

- 1" 1

/2 *

500

mba

r31

4252

3RP

50

- 2" *

500

mba

r31

4252

4FS

1B R

P 50

- 2"

1 ba

r31

4205

1FS

1B D

N 6

5 - 2

" 1/2

1 ba

r31

4198

3FS

1B D

N 8

0 - 3

"1

bar

3142

538

FS1B

DN

100

- 4"

1 ba

ron

requ

est

FS1B

DN

125

- 5"

1 ba

ron

requ

est

* De

faul

t spr

ing

is n

eutr

al fo

r out

let p

ress

ure

rang

e 10

-30

mba

r

SPRI

NG

for G

AS G

OVE

RNO

R an

d FI

LTER

FG

DRGa

s pre

ssur

e ra

nge

Code

Gree

n sp

ring

FGDR

15-

20-2

55÷

15 m

bar

3142

547

Neu

tral

sprin

g FG

DR 1

5-20

-25

10÷3

0 m

bar

3142

548

Viol

et sp

ring

FGDR

15-

20-2

525

÷80

mba

r31

4254

9Br

own

sprin

g FG

DR 1

5-20

-25

70÷1

60 m

bar

3142

550

Blue

sprin

g FG

DR 1

5-20

-25

150÷

280

mba

r31

4255

1W

hite

sprin

g FG

DR 1

5-20

-25

270÷

350

mba

r31

4255

2Gr

een

sprin

g FG

DR 3

2-40

5÷15

mba

r31

4255

3N

eutr

al sp

ring

FGDR

32-

4010

÷25

mba

r31

4255

4Vi

olet

sprin

g FG

DR 3

2-40

20÷7

0 m

bar

3142

555

Brow

n sp

ring

FGDR

32-

4065

÷130

mba

r31

4255

6W

hite

sprin

g FG

DR 3

2-40

120÷

250

mba

r31

4255

7Bl

ack

sprin

g FG

DR 3

2-40

240÷

350

mba

r31

4255

8Gr

een

sprin

g FG

DR 5

05÷

15 m

bar

3142

559

Neu

tral

sprin

g FG

DR 5

010

÷35

mba

r31

4256

0Vi

olet

sprin

g FG

DR 5

030

÷80

mba

r31

4256

1Br

own

sprin

g FG

DR 5

070

÷220

mba

r31

4256

2Bl

ue sp

ring

FGDR

50

210÷

350

mba

r31

4256

3

GAS

FILT

ERCo

deRP

15

- 1/2

"31

4195

7RP

20

- 3/4

"31

4204

5RP

25

- 1"

3142

046

RP 3

2 - 1

"1/4

3141

961

RP 4

0 - 1

"1/2

3141

954

RP 5

0 - 2

"31

2138

4DN

65

- 2"1

/231

2411

1DN

80

- 3"

3142

088

DN 1

00 -

4"31

4220

5DN

125

- 5"

3142

206

ANTI

VIBR

ATIO

N C

OU

PLIN

GCo

deRP

15

- 1/2

"31

2232

1RP

20

- 3/4

"31

2232

2RP

25

- 1"

3122

323

RP 3

2 - 1

"1/4

3122

324

RP 4

0 - 1

"1/2

3122

325

RP 5

0 - 2

"31

2232

6DN

65

- 2"1

/231

4206

0DN

80

- 3"

3122

328

DN 1

00 -

4"31

2232

9DN

125

- 5"

3142

061

BALL

VAL

VECo

deRP

15

- 1/2

"31

4200

0RP

20

- 3/4

"31

4225

4RP

25

- 1"

3121

430

RP 3

2 - 1

"1/4

3142

253

RP 4

0 - 1

"1/2

3142

101

RP 5

0 - 2

"31

4210

2DN

65

- 2"1

/231

4206

2DN

80

- 3"

3121

435

DN 1

00 -

4"31

4199

7DN

125

- 5"

3141

998

55www.ecoflam-burners.com

KIT

- ACS

FO

R G

AS

TIG

HTN

ESS

CON

TRO

LG

as t

rain

Code

Kit ti

ghtn

ess c

ontr

ol V

PS50

4 fo

r VCS

gas

val

veKI

TTC-

VPS5

04-V

CS31

4192

9Ki

t tigh

tnes

s con

trol

VPS

504

LPG

for V

CS g

as v

alve

KITT

C-LP

GVPS

504-

VCS

3142

238

Kit ti

ghtn

ess c

ontr

ol V

PS50

4 fo

r MB

and

VGD6

5-80

val

veKI

TTC-

VPS5

04-M

B-VG

DDN

65-8

031

2230

3Ki

t tigh

tnes

s con

trol

VPS

504

LPG

for M

B an

d VG

D65-

80 v

alve

KITT

C-LP

GVPS

504-

MB-

VGDD

N65

-80

3142

190

Kit ti

ghtn

ess c

ontr

ol V

PS50

4 fo

r VGD

2050

3 va

lve

KITT

C-VP

S504

-VGD

2050

331

2230

5Ki

t tigh

tnes

s con

trol

VPS

504

LPG

for V

GD20

503

valv

eKI

TTC-

LPGV

PS50

4-VG

D205

0331

4268

8Ki

t tigh

tnes

s con

trol

VDK

for V

GD10

0-12

5KI

TTC-

VDK2

0031

4192

2Ki

t tigh

tnes

s con

trol

LDU

KITT

C-LD

U11

3142

314

Kit a

dapt

or fo

r kit

VPS

pilo

t gas

trai

n31

4275

4

MAX

IMU

M G

AS P

RESS

URE

SW

ITCH

Out

put r

ange

Gas

pre

ssur

eCo

de

KITP

RES5

010

0÷58

00 k

W2,

5÷50

mba

r31

4192

1

KITP

RES1

5070

00÷2

5000

kW

30÷1

50 m

bar

3142

033

MAN

OM

ETER

+ P

USH

BU

TTO

NG

as p

ress

ure

Code

Gas m

anom

eter

0…60

mba

r 1/2

"31

4205

6Ga

s man

omet

er0…

250

mba

r 1/4

"31

4205

5Ga

s man

omet

er0…

1000

mba

r 1/4

"31

4205

4Pu

sh b

utton

1/4

"Di

amet

er 1

/4"

3142

058

Push

butt

on 1

/2"

Diam

eter

1/2

"31

4205

7

KIT

LPG

/ K

IT G

NG

as tr

ain

Code

KITL

PG-M

AXGA

S40-

120

MAX

GAS

40-

120

3122

301

KITA

DAPT

OR-

MAX

GAS4

0-12

0M

AX G

AS 4

0-12

031

2229

9KI

TLPG

-MAX

GAS1

70-2

50M

AX G

AS 1

70-2

5031

2230

2KI

TADA

PTO

R-M

AXGA

S170

-250

MAX

GAS

170

-250

3122

300

KITL

PG-M

AXGA

S350

-500

MAX

GAS

350

-500

3142

431

KITL

PG-B

LU50

0.1

BLU

500

.131

2448

7KI

TLPG

-BLU

700.

1BL

U 7

00.1

3124

488

KITL

PG-B

LU10

00.1

-150

0.1

BLU

100

0.1-

1200

.1-1

500.

131

2448

9KI

TLPG

-BLU

1700

.1-2

000.

1BL

U 1

700.

1-20

00.1

3142

667

Oth

er m

odel

kit

on re

ques

t

www.ecoflam-burners.com56

KIT

- ACS

: LO

AD C

ON

TRO

LLER

- PR

OBE

MO

DULA

TIN

G P

ID C

ON

TRO

LLER

- KI

T FO

R PR

OG

RESS

IVE

VERS

ION

Code

KITM

D-RW

F40

KITM

D-RW

F40

3122

291

MAT

CHIN

G P

ROBE

FO

R FU

LL M

D VE

RSIO

NCo

deW

ater

pro

be u

p to

0÷1

30° С

PRO

BE-W

ATER

130C

3122

316

Stea

m p

robe

0÷2

bar

PRO

BE-S

TEAM

2BAR

3124

100

Stea

m p

robe

0÷4

bar

PRO

BE-S

TEAM

4BAR

3122

317

Stea

m p

robe

0÷1

0 ba

rPR

OBE

-STE

AM10

BAR

3122

318

Stea

m p

robe

0÷1

6 ba

rPR

OBE

-STE

AM16

BAR

3122

319

Stea

m p

robe

0÷4

0 ba

rPR

OBE

-STE

AM40

BAR

3122

320

Exte

rnal

pro

be fr

om -3

5° u

p to

50°

СPR

OBE

-EXT

ERN

AL50

C31

2231

5Ho

t air

or li

quid

pro

be u

p to

0÷4

50° С

PRO

BE-H

OTA

IR-L

IQU

ID45

0C31

2231

4

SILE

NCE

R

PLAT

FORM

GAS

LIG

HT O

ILHE

AVY

OIL

GAS

/LIG

HT O

ILG

AS/H

EAVY

OIL

KITS

IL-2

60BL

U 7

00.1

- 12

00.1

MAI

OR

45 -

120

OIL

FLAM

50.

1 - 1

20.1

MU

LTIC

ALO

R 45

- 14

0M

ULT

IFLA

M 5

0.1

- 120

.1KI

TSIL

-280

BLU

150

0.1

- 200

0.1

MAI

OR

150.

1 - 2

00.1

OIL

FLAM

170

.1 -

200.

1M

ULT

ICAL

OR

170.

1 - 2

00.1

MU

LTIF

LAM

170

.1 -

200.

1KI

TSIL

-320

BLU

300

0.1

- 400

0.1

MAI

OR

300.

1 - 4

00.1

OIL

FLAM

300

.1 -

400.

1M

ULT

ICAL

OR

300.

1 - 4

00.1

MU

LTIF

LAM

300

.1 -

400.

1KI

TSIL

-380

BLU

500

0.1

- 600

0.1

MAI

OR

500.

1 - 6

00.1

OIL

FLAM

500

.1 -

600.

1M

ULT

ICAL

OR

500.

1 - 6

00.1

MU

LTIF

LAM

500

.1 -

600.

1KI

TSIL

-630

BLU

700

0.1

- 120

00.1

MAI

OR

700.

1 - 1

200.

1O

ILFL

AM 7

00.1

- 12

00.1

MU

LTIC

ALO

R 70

0.1

- 120

0.1

MU

LTIF

LAM

700

.1 -

1200

.1KI

TSIL

-710

BLU

150

00.1

- 18

000.

1M

AIO

R 15

00.1

- 18

00.1

OIL

FLAM

150

0.1

- 180

0.1

MU

LTIC

ALO

R 15

00.1

- 18

00.1

MU

LTIF

LAM

150

0.1

- 180

0.1

DUO

BLO

CKSe

para

te v

entil

ator

sile

ncer

/ So

und

proo

f pla

tform

on

requ

est

PLAT

FORM

Code

KITS

IL-2

6031

4191

1KI

TSIL

-280

3122

298

KITS

IL-3

2031

4191

3KI

TSIL

-380

3141

914

KITS

IL-6

3031

4227

6KI

TSIL

-710

3142

668

57www.ecoflam-burners.com

KIT

- ACS

: OIL

OPT

ION

S

DIAG

NO

STIC

TO

OLS

FO

R TH

ERM

OW

ATT

CON

TRO

L

KIT

FOR

AUTO

MAT

IC F

UEL

SW

ITCH

GAS

/OIL

FO

R DU

AL F

UEL

BU

RNER

SDe

scrip

tion

Code

KIT-

AUTO

MAT

ICFU

ELSW

ITCH

-MU

LTI

MU

LTIC

ALO

R - M

ULT

IFLA

M31

4202

1

Stan

dard

ver

sion

runn

ing

on m

anua

l fue

l sel

ectio

n m

ode

and

with

the

auto

mati

c ch

ange

over

the

syst

em c

hang

e fu

el tr

igge

red

by a

gas

pre

ssur

e sw

itch

or b

y a

timer

KIT

BIO

DIES

EL

Desc

riptio

nCo

deKI

TBIO

DIES

EL-P

UM

P-AS

47M

AX 1

-30

and

MAX

P 2

5 AB

HS

3141

917

KITB

IODI

ESEL

-PU

MP-

AT2/

AT3

MAX

P 1

2-15

AB

HS31

2410

3

MAG

NET

IC +

SEL

FCLE

ANIN

G F

ILTER

Desc

riptio

nCo

deKI

TOIL

50KG

-MAG

NET

IC+S

ELFC

LEAN

ING-

FILT

ERM

AXFL

AM ra

nge

3142

092

KITO

IL25

0KG-

MAG

NET

IC+S

ELFC

LEAN

ING-

FILT

ERO

ILFL

AM ra

nge

3141

965

KIT

WIE

LAN

D PL

UG

SDe

scrip

tion

Code

KITW

P-M

AIO

R35-

300.

1PAB

MAI

OR

45 -

300.

131

4203

7KI

TWP-

BLU

500.

1-20

00.1

PAB

BLU

500

.1 -

2000

.1 P

AB31

4203

4KI

TWP-

BLU

/MU

LTIC

ALO

R-PR

/MD

BLU

- M

ULT

ICAL

OR

PR/M

D31

4193

2

SEPA

RATE

PRE

-HEA

TER

UN

ITFr

om O

ILFL

AM 3

00.1

pre

-hea

ter c

an b

e su

pplie

d se

para

tely

with

ext

ra c

ost

LIG

HT O

IL P

UM

PIN

G U

NIT

Sepa

rate

serv

ice

tank

s and

pum

p un

its

HEAV

Y O

IL H

EATI

NG

AN

D PU

MPI

NG

UN

IT“O

IL R

ING”

can

be

desig

n an

d de

liver

ed a

ssem

bled

on

skid

or o

ffere

d as

sing

le c

ompo

nent

SWIR

L SY

STEM

Avai

labl

e fo

r diff

eren

t fue

l bur

ner b

last

tube

Swirl

s for

bla

st tu

be th

at c

an re

duce

flam

e le

nght

up

to 1

0-50

% d

epen

ding

on

fuel

, ba

ckpr

essu

re a

nd sh

ape

of c

ombu

stion

cha

mbe

r

DIAG

NO

STIC

TO

OL

Code

E-BC

U D

iagn

ostic

tool

for 1

stag

e BC

U31

4293

1PC

inte

rfac

e fo

r BCU

3833

018

www.ecoflam-burners.com58

BURNER SELECTION FORMSECTION 1 - GENERAL INFORMATION

CUSTOMER - COUNTRY

REFERENCE SALES PERSON

REQUEST DATE

INSTALLATION LOCATION

SEGMENT heating bakery projectsheating OEM dryers other industry

SECTION 2 - BOILER INFORMATION

BOILER TYPE

three pass boilerreverse flame boilerwater tube boilerdiathermic boiler

APPLICATION TYPEincineratordryer / hot air generatoroven

HEAT TRANSFER MEDIUM

steam (saturated)STEAM

Steam capacity [TPH]

steam (superheated) Required steam pressure bar

hot water Steam temperature [°C]

salt / oilOTHER

Medium temperature [°C]

others Medium inlet temperature [°C]

POWER REQUIREMENT

Boiler Output [kW]

1 kW = 860 kcal/h

BOILER LOCATION outdoorBoiler Input [kW] indoorBoiler efficiency [%] HEIGHT ABOVE SEA LEVEL [m]

Burner power [kW]

FURNACE CHAMBER DATA

Backpressure [mbar] DIMENSIONS [mm]Inner diameter

Furnace position horizontal Lengthtop-down Return chamber lengthbottom-up Length

Height

Required blast tube Lenght

min [mm] Widthmax [mm]

ELECTRICAL SUPPLY DATA

Voltage single phase 110 V 220 V 230 V 240 VVoltage three phase 220 V 380 V 400 V 415 V 440 V 460 V 480 VFrequency 50 Hz 60 HzRequired IP factor IP40 IP54 other:

SECTION 3 - FUEL INFORMATION

LIGHT OIL - HEAVY OIL GAS / LPG BIOGAS-TOWNGAS (Max H2S<0,1%)

Type: …………………………............... Type: ……………………….............. Type: ………………………………………..................

Lower calorific value [kcal/kg] Lower calorific value [kcal/m3] Lower calorific value [kcal/m3]

Viscosity at 50°C [°E] Supply pressure [mbar] Supply pressure [mbar]

Required flowrate [kg/h] Required flowrate [m3/h] Required flowrate [m3/h]

Boiler brandBoiler modelBoiler manuf. year

59www.ecoflam-burners.com

BURNER SELECTION FORMSECTION 4 - BURNER

BURNER TYPE

Combustion air temperature [°C] (Max 200°C)

Monoblock Duoblock Heat exchanger pressure losses [mbar]

Current fan (if existing) flowrate: [m3/h]pressure: [mbar]

BURNER POWER refer to the field "burner power" in the section "power requirement"

NOMINAL TURNDOWN RATIO mechanical: 1:3 electronic with inverter: 1:8electronic: 1:6 electronic with inverter: 1:10

EMISSIONS LEVEL NOx: Gas: <120 mg/kWh <80 mg/kWh Light Oil: <250 mg/kWh <185 mg/kWh <120 mg/kWh

EN676Class 2 Class 3

EN267Class 1 Class 2 Class 3

CO: 0...100 mg/kWh 0...110 mg/kWh 0...60 mg/kWh

FUEL SUPPLYsingle fuel FUEL 1: Automatic fuel

changeovertwo fuels FUEL 2:three fuels FUEL 3:

CONTROL TYPE

1 stage2 stages2 stage progressive mechanicalmodulating mechanical with PIDmodulating electronic

OPTIONS FORELECTRONIC VERSION

inverter (modulating electronic only)O2 trim (modulating electronic only)CO trim (modulating electronic only)

ELECTRICALCONFIGURATION

standard electrical panelloosen form with derivative panelseparate switch cabinet

Other requirements: specify

SECTION 5 - GAS TRAIN CONFIGURATION

Gas governor and filter Tightness control Maximum pressure switch

Gas train type

Dungs MultiBloc FGDR Max 500 mbar VPS KITPRES50Siemens VGD FS1B Max 1 bar VDK up to 6 MWKromschröder VCS ST4B Max 4 bar LDU KITPRES150Honeywell Filter Max 1 bar Electronic up to 25 MW

Other requirements: specify

NOTES - ADDITIONAL INFORMATION

Ecoflam Bruciatori S.p.A.Via Roma, 64 - 31023 Resana (TV) - ItalyTel. +39 0423 719500Fax +39 0423 719580http://www.ecoflam-burners.come-mail: [email protected]à soggetta alla direzione e al coordinamento di Ariston Thermo S.p.A.Via A. Merloni, 45 - 60044 Fabriano (AN) - CF 01026940427

Version 1.3Date: 24/10/2012.Ecoflam Bruciatori S.p.A. reserves the right to make any adjustments, without prior notice, which is considered necessaryor useful to its products, without affecting their main features.