cat# 71554 30 watts 1/2 knuckle mount rohs phnrj3ey · 2016. 11. 3. · 71554. rohs. 82.5. qpl id #...

13
Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure Output Voltage Output Current Driver Efficiency LED Manufacturer LED Type LED Quantity LED Efficacy Color Temperature Photocell - Lifespan Warranty IP Rating Operating Temperature Storage Temperature.Humidity Safety Norms Withstand Voltage Grounding Resistance Electromagnetic Compatibility Dimension Pls refer to attached dimensional drawing Q'ty / Carton The above info is for reference only. 0.38A Max 29.62 W 3718 LM 125.52 LM/W OTHERS 8PCS SAFETY&EMC UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471 I/P-FG: 2121VDC ≤0.5Ω,OK EN55015, EN61000-2-3, EN61000-3-3, EN61547 LIFESPAN & ENVIRONMENT 50,000+ Hrs. IP65, Wet Locations -20℃—+55℃ -40℃—+80℃ , 10—90% RH 5 Years LED DRIVER LED 5000K Not Included 130 LM/W 18 PCS LUXEON 3030 Phillips LUMILED 89% Cat# 71554 30 Watts 1/2" Knuckle Mount 0.7A Model: OVERALL LAMP PARAMETERS 100-277VAC 50/60HZ PF ≥0.92 120 x 90° Aluminium + Tempered Glass 24-45VDC 71554 RoHS 82.5 QPL ID # PHNRJ3EY

Upload: others

Post on 18-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Input Voltage

    Input Current

    Input Power

    Power Factor

    Luminance

    Luminous Efficiency

    CRI

    Beam Angle

    Main Structure

    Output Voltage

    Output Current

    Driver Efficiency

    LED Manufacturer

    LED Type

    LED Quantity

    LED Efficacy

    Color Temperature

    Photocell -

    Lifespan

    Warranty

    IP Rating

    Operating Temperature

    Storage Temperature.Humidity

    Safety Norms

    Withstand Voltage

    Grounding Resistance

    Electromagnetic Compatibility

    Dimension Pls refer to attached dimensional drawing

    Q'ty / Carton

    The above info is for reference only.

    0.38A Max

    29.62 W

    3718 LM

    125.52 LM/W

    OTHERS

    8PCS

    SAFETY&EMC

    UL1598,UL8750, EN60598, EN61347-2-13, EN62031, EN62471

    I/P-FG: 2121VDC

    ≤0.5Ω,OK

    EN55015, EN61000-2-3, EN61000-3-3, EN61547

    LIFESPAN & ENVIRONMENT

    50,000+ Hrs.

    IP65, Wet Locations

    -20℃—+55℃

    -40℃—+80℃ , 10—90% RH

    5 Years

    LED DRIVER

    LED

    5000K

    Not Included

    130 LM/W

    18 PCS

    LUXEON 3030

    Phillips LUMILED

    89%

    Cat# 7155430 Watts

    1/2" Knuckle Mount

    0.7A

    Model:

    OVERALL LAMP PARAMETERS

    100-277VAC 50/60HZ

    PF ≥0.92

    120 x 90°

    Aluminium + Tempered Glass

    24-45VDC

    71554

    RoHS

    82.5

    QPL ID # PHNRJ3EY

  • STANDARD-TECH Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    1 / 11

    NVLAP LAB CODE 201011-0

    LM-79-08 Test Report

    For

    Morris Products Inc.

    53 Carey Rd. Queensbury, NY 12804

    Architectural Flood and Spot Luminaires

    Model name(s): 71532, 71804, 71805, 71806, 71554, 71822, 71555, 71556

    71581, 71861

    Representative (Tested) Model: 71532

    Model Different: All construction and rating are the same, except CCT

    Test & Report By: Review By:

    Johnson Sun Engineer: Johnson Sun Manager: Tommy Liang

    Update: Nov.03, 2016

    Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

    any agency of the Federal Government.

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    2 / 11

    1.1 Product Information:

    Organization Name Morris Products Inc.

    Brand Name MORRIS Model Number 71532SKU (if available) N/A

    Type of Luminaire (for integral lamps,

    list base type and lamp type) Architectural Flood and Spot Luminaires

    Rated Voltage / Frequency 100 -277Vac, 50/60 Hz

    Nominal Power 30W

    Rated Initial Lamp Lumen --

    Declared CCT 3000K,4000K,5000K

    LED Manufacturer Philips Lumileds

    LED Model L130-2780003000W21

    Sample Number GZE161105-AB1(3000K),AB2(5000K)

    Luminaire Aperture (for downlights) -- in.

    Luminaire Length -- mm

    Luminaires Width -- mm

    Number of Units (modular products) N/A s

    Photo

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    3 / 11

    1.2 Test Specifications:

    Date of Receipt : Oct.31,2016

    Date of Test : Nov.01,2016

    Test item

    1. Total Luminous Flux

    2. Luminous Distribution Intensity

    3. Luminous Efficacy

    4. Correlated Color Temperature

    5. Color Rendering Index

    6. Chromaticity Coordinate

    7. Electrical Parameters

    Reference Standard

    1. IES LM-79-2008 Electrical and Photometric Measurements of

    Solid-State Lighting Products

    2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid

    State Lighting Products

    3. CIE 13.3-1995 Method of Measuring and Specifying Colour

    Rendering Properties of Light Sources

    4. CIE 15-2004 Technical Report Colorimetry

    5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

    6. IESNA TM-16-05 Technical Memorandum on Light Emitting

    Diode (LED) Sources and Systems

    Reference Work Instruction QD25

    1.3 Test Methods

    1) Photometric and Light Distribution Measurement – Goniophotometer Method:

    Photometric parameters were measured using the goniophotometer and software. The ambient

    temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

    sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.

    It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

    calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

    2) Chromaticity Measurement – Sphere-Spectroradiometer Method:

    Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.

    The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

    measurements were made using a spectroradiometer connected by a fiber optic cable and detector

    through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,

    60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color

    temperature and color rendering index were calculated from the spectral power distribution taken at 5

    nm intervals over the range of 380 to 780 nm.

    3) Electrical Measurements:

    Electrical parameters were measured using power meters incorporated in goniophotometer or

    sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at

    25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before

    measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion

    were measured by and read from the power meter.

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    4 / 11

    2.1 Electrical, Photometric and Chromaticity Measurements

    (Refer to Work Instruction QD25)

    Test date 2016-11-01 Test Ambient: 25.2 º C

    Test Orientation As intended Stabilization Time (min) 90

    Model Number 71532

    Electrical Measurement :

    Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

    GZE161105-

    AB1

    120.0 60 0.2515 29.57 0.9797 15.97

    277.0 60 0.1150 29.40 0.9226 17.11

    DLC Pass Criteria >= 0.9(-3%) =1000 (-10%)

    Luminous Efficacy (lm/W) 116.78 115.56 Standard: >=

    90(-3%)

    Premium: >=

    110(-3%)

    Zonal lumens in the 0-90° zone (%) 99.9 -- >=85(-3)

    Beam Angle (°) 110.8 -- --

    Center Beam Candle Power (cd) 1131 -- --

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    5 / 11

    Zonal Lumen Tabulation

    Zonal Lumen Summary

    Zone Lumens % Luminaire

    0-30 857.7 24.8%

    0-40 1,452.3 42.1%

    0-60 2,774.1 80.4%

    60-90 674.5 19.5%

    70-100 258.6 7.5%

    90-120 0.8 0%

    0-90 3,448.7 99.9%

    90-180 3.8 0.1%

    0-180 3,452.5 100%

    Lumens Per Zone

    Zone Lumens % Total Zone Lumens % Total

    0-10 106.2 3.1% 90-100 0.5 0%

    10-20 296.3 8.6% 100-110 0.0 0%

    20-30 455.2 13.2% 110-120 0.2 0%

    30-40 594.7 17.2% 120-130 0.5 0%

    40-50 666.0 19.3% 130-140 0.7 0%

    50-60 655.8 19.0% 140-150 0.7 0%

    60-70 416.4 12.1% 150-160 0.6 0%

    70-80 192.9 5.6% 160-170 0.4 0%

    80-90 65.2 1.9% 170-180 0.1 0%

    Spectral Power Distribution & Chromaticity Diagram

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    6 / 11

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    7 / 11

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    8 / 11

    BUG Rating: B1-U1-G1

  • STANDARD-TECHNVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    9 / 11

    2.2 Electrical, Photometric and Chromaticity Measurements

    (Refer to Work Instruction QD25)

    Test date 2016-11-01 Test Ambient: 25.2 º C

    Test Orientation As intended Stabilization Time (min) 90

    Model Number 71532

    Electrical Measurement :

    Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

    GZE161105-

    AB2

    120.0 60 0.2520 29.62 0.9795 15.93

    277.0 60 0.1153 29.45 0.9221 17.07

    DLC Pass Criteria >= 0.9(-3%) =2000 (-10%)

    Luminous Efficacy (lm/W) 125.52 124.21 Standard: >=

    90(-3%)

    Premium: >=

    110(-3%)

  • STANDARD-TECH

    NVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    10 / 11

    Spectral Power Distribution & Chromaticity Diagram

  • STANDARD-TECH

    NVLAP LAB CODE 201011-0

    Report No.: GZE161105-AB

    Laboratory: Standard-Tech Co. Ltd Testing Center

    NVLAP CODE: 201011-0

    Report Format Number STD/QR4909-A/2

    Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

    Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

    11 / 11

    3. Test Equipment

    Equipment ID Equipment Name Last Calibration Date Next Calibration Date

    ST-R-336 2 meter Integrating Sphere 2016-07-01 2017-06-30

    ST-R-331 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30

    D204 Standard Lamp 2016-07-01 2017-06-30

    PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30

    EE-09 Goniophotometer system 2016-07-01 2017-06-30

    D908S Standard Lamp 2016-07-01 2017-06-30

    PF210 Power Meter for Goniophotometer 2016-07-01 2017-06-30

    ST-R-181A Temperature Tester 2016-07-01 2017-06-30

    Uncertainty:

    Photometric Measurement (Sphere):1.74%

    Chromaticity Measurement(Sphere):14.3K

    Photometric Measurement(Goniophotometer):1.62%

    ****** END OF REPORT ******