SPECIFICATION SUBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 1 12.12.18 Caséta Wireless Load Controls The Caséta Wireless family of dimmers, switches, and fan controls can be controlled directly and remotely when paired with Pico remote controls providing a system that delivers convenience and ease of installation. Caséta Wireless dimmers, switches, and fan controls use Lutron patented Clear Connect RF Technology which enables wireless communication with Pico remote controls and the Lutron Smart Bridge and Smart Bridge PRO. Features Works with Pico Remote Control Works with the Lutron App (via a Smart Bridge or Smart Bridge PRO) 1 Lutron patented Clear Connect RF Technology works through walls and floors Includes Front Accessible Service Switch (FASS) for safe lamp replacement Works with Lutron Radio Powr Savr occupancy and vacancy sensors in standalone applications (sensors do not work with Smart Bridge or Smart Bridge PRO) Caséta Wireless In-Wall Switches Caséta Wireless In-Wall Dimmers Caséta Wireless Plug-In Lamp Dimmer Caséta Wireless ELV+ Dimmer Caséta Wireless Fan Control 1 The Lutron App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The Lutron App is compatible with iOSR devices version 8.0 or later and AndroidT devices 4.0 or later. Note: Certain models or load types will require a neutral connection (see Load Types and Capacity sections).

Upload: others

Post on 01-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 1 12.12.18

Caséta Wireless Load ControlsThe Caséta Wireless family of dimmers, switches, and fan controls can be controlled directly and remotely when paired with Pico remote controls providing a system that delivers convenience and ease of installation.Caséta Wireless dimmers, switches, and fan controls use Lutron patented Clear Connect RF Technology which enables wireless communication with Pico remote controls and the Lutron Smart Bridge and Smart Bridge PRO.

Features

•Works with Pico Remote Control•Works with the Lutron App (via a Smart Bridge or

Smart Bridge PRO)1

•Lutron patented Clear Connect RF Technology works through walls and floors

•Includes Front Accessible Service Switch (FASS) for safe lamp replacement

•Works with Lutron Radio Powr Savr occupancy and vacancy sensors in standalone applications (sensors do not work with Smart Bridge or Smart Bridge PRO)

Caséta Wireless In-Wall Switches

Caséta Wireless In-Wall Dimmers

Caséta Wireless Plug-In Lamp Dimmer

Caséta Wireless ELV+ Dimmer

Caséta Wireless Fan Control

1 The Lutron App is required for setup and usage with the Smart Bridge and Smart Bridge PRO. The Lutron App is compatible with iOSR devices version 8.0 or later and AndroidT devices 4.0 or later.

Note: Certain models or load types will require a neutral connection (see Load Types and Capacity sections).

Page 2: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 2 12.12.18

SpecificationsRegulatory Approvals

• cULusListed• NOMCertified• FCCApproved.ComplieswiththelimitsforaClassB

digital device, pursuant to Part 15 of the FCC Rules• IndustryCanadaCertified• IFTELCertified• NEMA410(-5ANS, -6ANS,-5WS,-10NXD,-5NE)

PowerOperating voltage:

•120V~ 50/60 Hz: -3PCL, -6WCL, -10NXD, -6ANS, -5ANS,-5NE,-FSQN

•120/277V~50/60Hz:-5WS-DV

Key Design Features• Testedtowithstandelectrostaticdischargewithout

damage or memory loss, in accordance with IEC61000-4-2.

• Testedtowithstandsurgevoltageswithoutdamageorlossofoperation,inaccordancewithIEEEC62.41-1991 Recommended Practice on Surge VoltagesinLow-VoltageACPowerCircuits.

• Loadcontrolsalwaysoperatelocallyanddonotrequire system control.

• Powerfailurememory:shouldpowerbeinterrupted,the control will return to its previously set level prior to the interruption when power is restored.

• PD-5WS-DV,PD-5ANS, PD-6ANS, and PD-10NXD use conventional 3-way wiring.

• UsesLutronClarowallplatesordesigner-stylewallplates from other manufacturers. Wallplates are sold separately.

• LutronClarowallplatessnaponwithnovisiblemeans of attachment.

• Requiresa1-gangU.S.wallbox.31⁄2 in (89 mm) depth recommended, 21⁄4 in (57 mm) depth minimum1.

• GreenstatusLED(s)toindicateloadstatus.• PD-FSQNprovides4quietfanspeedsplusOFFfora

single ceiling fan.

System Communications and Capacity• CasétaWirelessin-wallswitches,dimmers,andfan

controls communicate with Pico remote controls and the Lutron Smart Bridge/Smart Bridge PRO through Radio Frequency (RF).

• TheCasétaWirelessin-wallswitches,dimmers,andfan controls communicate with Lutron Radio Powr Savr cccupancy and vacancy sensors in a standalone application. Sensors do not work with Smart Bridge or Smart Bridge PRO.

• TheCasétaWirelessin-wallswitches,dimmers,and fan controls must be located within 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls, of Pico remote controls and Lutron Smart Bridge devices.

Device limits• PicoremotecontrolsandRadioPowrSavr

occupancy sensors: up to 10 devices (total) may be paired to each Caséta Wireless in-wall switch/dimmer (with no Smart Bridge installed).

• SmartBridgeorSmartBridge PRO system: up to 50 total wireless devices (Caséta wireless dimmers/switches, Pico remote controls, and shades) are supported per system. Smart Bridge or Smart Bridge PRO counts as one device.

Environment• Ambientoperatingtemperature:32 °Fto104 °F

(0 °Cto40 °C),0%to90%humidity, non-condensing. Indoor use only.

• PD-5WS-DV,PD-5ANS, PD-6ANS, and PD-10NXD can be used with mechanical switch in 3-way applications.

1PD-FSQNrequires2` in minimum depth

Page 3: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 3 12.12.18

PRO Dimmer

PD-10NXD

Plug-In Dimmer PD-3PCL

In-Wall Dimmer

PD-6WCL

ELV+ Dimmer PD-5NE

2-wire Switch

PD-5WS-DV

Neutral Switch

PD-5ANS, PD-6ANS

Fan Control

PD-FSQN

Simple two-wire installation (no neutral wire required)

√ 1 √ √

Capable of dimming loads √ √ √ √

Favorite button (user defined one-touch preset level)

√ √

WorkswithHi-lume1%2-WireLEDDrivers (Forward-phase only)

√ √ √ √

WorkswithPowerInterfaces(PHPMandGRX-TVI)

√ √

WorkswithPowerInterfaces(PHPM-SW) √

No wiring required √

Controls speed of a single ceiling fan √

1 In some low-wattage applications the PD-10NXD will require a neutral wire connection.

Features

Page 4: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 4 12.12.18

Load Type and Capacity - Switches and Fan Control

Model Number Description Voltage Load Type Minimum LoadMaximum Load 3

Not Ganged End of Gang Middle of Gang

PD-5WS-DV1 Two-wire switch

120V~ Incandescent / Halogen 25 W 600 W 450 W 350 W

277V~ Incandescent / Halogen 25 W 1350 W 1100 W 800 W

120V~ MLV 25 W 600VA/475W 450VA/350W 350VA/275W277V~ MLV 25 W 1350VA/1075W 1100VA/875W 800VA/625W

120V~ GeneralPurpose Fan 0.4 A 3 A 3 A 3 A

120/277V~ LED UseLUT-MLC2 5 A 4 A 3 A120/277V~ Fluorescent UseLUT-MLC2 5 A 4 A 3 A120V~ ELV UseLUT-MLC2 600 W 450 W 350 W277V~ ELV UseLUT-MLC2 1350 W 1100 W 800 W

PD-5ANS

Neutral-wire switch (neutral connection required)

120V~

Incandescent / Halogen 10 W 600 W 600 W 600 W

MLV 10 W 600VA 600VA 600VAFan 0.1 A 3 A 3 A 3 ALED 1 bulb 5 A 5 A 5 AFluorescent 1 ballast 5 A 5 A 5 AELV 10 W 600 W 600 W 600 WPHPM-SW 1 interface 2 interfaces 2 interfaces 2 interfaces

PD-6ANS

Neutral-wire switch (neutral connection required)

120V~

Incandescent / Halogen 10 W 720 W 720 W 600 W

MLV 10 W 720VA 720VA 600VAFan 0.1 A 3.6 A 3.6 A 3.6 ALED 1 bulb 6 A 6 A 5 AFluorescent 1 ballast 6 A 6 A 5 AELV 10 W 720 W 720 W 600 WPHPM-SW 1 interface 3 interfaces 3 interfaces 3 interfaces

PD-FSQN4

Fan speed control (neutral connection required)

120V~

Ceiling Fan (Permanent split-capacitor motor)

0.1 A 1.5 A 1.5 A 1.5 A

1 No neutral wire required.2 ToensureproperoperationoftheswitchwithLED,fluorescent,andELVloads,aLUT-MLC(included)mayberequired,especiallyatlowerwattages.Ifthe

statusLEDontheswitchisflashingorsolidredincolor,aLUT-MLCmustbeinstalled.Toguaranteebestperformance,installingaLUT-MLCwiththeseloadtypesregardlessofwattageisrecommended.Rarely,someloadtypesmaystillflickerorglowintheoffstateevenwiththeLUT-MLCinstalled,inwhichcaseadifferentloadmayberequiredormorethanoneLUT-MLCisrequired.

3 See“GangingandDerating”section.4 Notforusewithfansthathaveintegratedfanspeedand/orlightcontrolmodules,DCmotorfans,fanswithremotecontrols,bathroomorkitchenexhaust

type fans.

Page 5: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 5 12.12.18

1 Cannot be ganged.2 NeedtochangeloadtypetoMLV.Seewww.casetawireless.com/change_phase3 See bulb list at www.lutron.com/led4 ForPD-10NXD,aneutralconnectionisrequiredforMLVloads,LEDdrivers,dimmableballasts,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).5 CompatibledimmableballastsincludeTu-Wire,MarkX,andPowerSenseR.6 These loads are best operated using a forward-phase control. Consult www.casetawireless.com/bulblist to ensure the appropriate phase for bulb models used.7 SSL7 compliant when in forward-phase. 8 Canadian packaged product.9 Available in WH only.10 Kit model number. Kit includes (1) PD-3PCL-WH, and (1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White).11 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(1)PD-3PCL-WH,(1)PJ2-3BRL-WH-L01R(3-buttonwith

raise/lowerPicowirelesscontrolinWhite)and(1)L-PED1-WH(SingletabletoppedestalinWhite).12 Kit model number. Kit includes (1) PD-6WCL-WH, (1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White), and (1) CW-1-WH (single-gang

faceplate in White).13 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(1)PD-6WCL-WH,(1)PJ2-3BRL-WH-L01R(3-buttonwith

raise/lower Pico wireless control in White), and (1) CW-1-WH (single-gang faceplate in White).14 Kitmodelnumber.Kitincludes(1)L-BDG2-WH(CasétaWirelessSmartBridgewithHomeKittechnology),(2)PD-6WCL-WH,(2)PJ2-3BRL-WH-L01R(3-buttonwith

raise/lowerPicowirelesscontrolinWhite),(2)L-PED1-WH(SingletabletoppedestalinWhite)and(2)CW-1-WH(single-gangfaceplateinWhite).15 PROKitmodelnumber.Kitincludes(1)L-BDGPRO2-WH(CasétaWirelessSmartBridgePROwithHomeKittechnology),(1)PD-6WCL-WH,

(1) PJ2-3BRL-WH-L01R (3-button with raise/lower Pico wireless control in White) and (1) CW-1-WH (single-gang faceplate in White).

Load Type and Capacity - Dimmers

Model Number Description Voltage Load Type Minimum Load

Maximum LoadNot Ganged End of Gang Middle of Gang

PD-10NXDPD-10NXD-XX-C 8

Wireless In-Wall Dimmer PRO (neutral connection required for certain load types)4

120V~

Incandescent / Halogen10 W with neutral (25 W without neutral)

1000 W 800 W 600 W

MLVHalogen 10 W 1000VA 800VA 600VAMLVLED See Application Note #559CFL/LED(120V~ Rated)3 1 bulb3 250 W 250 W 250 W

Hi-lume1%2-WireLEDdrivers 1 driver 13 drivers 13 drivers 13 drivers

Dimmable Ballasts5 1 ballast 1000VA 800VA 600VAPHPM-PA/3FandGRX-TVI4 1 interface 3 interfaces 3 interfaces 3 interfaces

PD-3PCL1, 9

PD-3PCL-WH-C 8P-PKG1P-WH9, 10

P-BDG-PKG2P9, 11

Wireless Plug-In Lamp Dimmer

120V~

Incandescent / Halogen 10 W 300 W N/A N/A

CFL/LED(120V~ Rated)3 1 bulb3 100 W N/A N/A

PD-5NEPD-5NE-XX-C8

Phase Selectable Dimmer (neutral connection required)

120V~

Incandescent / Halogen 10 W 500 W 400 W 300 WCFL/LED (120V~ Rated)3, 6, 7 1 bulb3 250 W 250 W 250 W

MLVHalogen 2, 6, 7 10 W 400VA 400VA 400VAELVHalogen 10 W 500 W 400 W 300 WHi-lume1%2-WireLEDdrivers 6, 7 1 driver 20 drivers 20 drivers 20 drivers

Dimmable Ballasts 5, 6, 7 1 ballast 400VA 400VA 400VAPHPM-PA/3FandGRX-TVI6, 7 1 interface 3 interfaces 3 interfaces 3 interfaces

ELVLED See Application Note #559MLVLED6, 7 See Application Note #559

PD-6WCLPD-6WCL-XX-C 8P-PKG1W-WH9, 12

P-BDG-PKG2W9, 13

P-BDG-PKG2W9, 14

P-BDGPRO-PKG1W9, 15

Wireless In-Wall Dimmer

120V~

Incandescent / Halogen 25 W 600 W 500 W 400 W

CFL/LED (120V~ Rated)3 1 bulb3 150 W 150 W 150 W

Page 6: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 6 12.12.18

Ganging and DeratingWhengangingwithotherswitches/dimmersinthesamewallbox,deratingisrequired.See“LoadTypeandCapacity”charts.

Eachswitch/dimmerhas inside fins removed

Middleofgangedswitches/dimmers have all fins removed

Do not remove outside fins on ends of ganged switches/dimmers

Do not remove outside fins on ends of ganged switches/dimmers

Eachswitch/dimmerhas inside fins removed

Middleofgangedswitches/dimmers have all fins removed

Page 7: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 7 12.12.18

Operation

FASS — Front Accessible Service SwitchImportant Notice: To service load, remove power by pulling out the FASS as far as possible. To restore power after servicing load, push the FASS back in completely.

FASS

TM • FAS

STM • FASSTM • FASSTM

• F

AS

STM

• F

ASSTM •

Status LEDIndicates load status; glows softly as night light when load is off

ELV+Dimmer and In-Wall Dimmers

FASS

TM • FAS

STM • FASSTM • FASSTM

• F

AS

STM

• FA

SSTM •

FASSFront Accessible Service Switch

FASSFront Accessible Service Switch

FASSFront Accessible Service Switch

On

Status LEDsIndicates load status; glows softly as night light when load is off

Off

Brighter

Darker

In-Wall Switches

Favorite (Userdefineslightlevel. OnlyavailableinPD-5NE)

On

Off

Plug-In Dimmer Fan Control

Status LEDIndicates load status; glows softly as night light when load is off

On

Off

Brighter

Darker

FASS

TM • FASS

TM • FASSTM • FASSTM

• F

ASS

TM • FA

SSTM •

High

Status LEDsIndicates load status; glows softly as a night light when the fan is off

Off

Faster

Slower

Favorite (Userdefinesfanspeed)

Page 8: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 8 12.12.18

Mounting

Wallplate Adapter / Wallplate purchased separately (Claro Wallplate [CW-1] shown)

Wallplate Adapter Wallplate

Wallbox

Switch/Dimmer

AdapterMountingScrews

Switch/DimmerMountingScrews

Page 9: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 9 12.12.18

DimensionsIn-Wall Switches and Dimmers Fan ControlFront View Side View

5/16 in(8 mm)

5/16 in(8 mm)

11⁄8 in(30 mm)

19⁄16 in(39 mm)

411⁄16 in(119 mm)

215⁄16 in(75 mm)

215⁄16 in(75 mm)

13⁄16 in(30 mm)

23⁄16 in(56 mm)

Front View Side View

31⁄8 in(79 mm)

Plug-In Dimmer

Front View Side View

411⁄16 in(119 mm)

2 9⁄16 in(65 mm)

Page 10: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 10 12.12.18

Wiring Diagrams - Switches

1 When using controls without a mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox

within the circuit. 3 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.

Single Location Installation

PD-5WS-DV

PD-5ANS, PD-6ANS

PD-5WS-DV

PD-5ANS or PD-6ANS

LUT-MLC2Load

Load

Line/Hot

Line/Hot

Neutral

Neutral

Green

Green

Ground

Ground

Black

Black

Black

Red 3

Blue 1

Blue 1

120/277V~ 50/60 Hz

120V~ 50/60 Hz

(continuedonnextpage…)

White

Page 11: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 11 12.12.18

Wiring Diagrams - Switches (cont.)3-Way Installation (with mechanical switch)

Option 1

PD-5WS-DV1Mechanical

Switch 1

BrassBrass

LUT-MLC2Load

Line/Hot

Location 1

Location 2

Neutral

Green

Ground

Ground

Black Black

Blue

120/277V~ 50/60 Hz

Black

Jumper wire

PD-5WS-DV (Load-side)

1 Location of Caséta Wireless in-wall switch and mechanical switch may be reversed.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionboxwithinthecircuit.

Line/Hot

Neutral

120/277V~ 50/60 Hz

MechanicalSwitch 1

PD-5WS-DV1Black

Location 1 Location 2

Ground

Green

Black

Blue

Brass

Black

Brass

Jumper wireGround

LUT-MLC2Load

PD-5WS-DV (Line-side)

(continuedonnextpage…)

Page 12: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 12 12.12.18

Wiring Diagrams - Switches (cont.)3-Way Installation (with mechanical switch)

Option 1 (cont.)

Location 2

Location 2

PD-5ANS or PD-6ANS 1

MechanicalSwitch 1

BrassBrass

Load

Line/Hot

Neutral

GreenWhiteGround

Ground

Black Red 2

Blue

120V~ 50/60 Hz

Black Jumper wire

PD-5ANS, PD-6ANS (Load-side)

Ground

GreenWhite

Line/Hot

Neutral

120V~ 50/60 Hz

Black Red 2

Blue Brass

Jumper wire

Black

Brass

Load

PD-5ANS or PD-6ANS 1

PD-5ANS, PD-6ANS (Line-side)

MechanicalSwitch 1

Ground

Location 1

Location 1

1 Location of Caséta Wireless in-wall switch and mechanical switch may be reversed.2 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.

Page 13: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 13 12.12.18

Wiring Diagrams - Switches (cont.)

1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox

within the circuit. 3 The mechanical switch will need to be removed so the Pico remote control can be installed.4 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.

3-Way Installation (with Pico remote controls)

Option2:PJ2-2B-xxandwallboxmountingadapters(PICO-WBX-ADAPT)

(continuedonnextpage…)

BlackBlack

PD-5WS-DV

Pico Remote

Control and WallboxMountingAdapter 3

LUT-MLC2Load

Line/Hot

Neutral

Green

Ground

Black

Blue1

120/277V~ 50/60 Hz

Travelers

PD-5WS-DVLocation 1 Location 2

Page 14: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 14 12.12.18

Wiring Diagrams - Switches (cont.)

Multi-location Installation (3 or more switches control the load)WithPicoremotecontrols(PJ2-2B-xx)andwallboxmountingadapters(PICO-WBX-ADAPT)

BlackBlack

PD-5ANS or PD-6ANS

Pico Remote

Control and WallboxMountingAdapter 3

Load

Line/Hot

Neutral

GreenWhite

Ground

Red4

Blue1

120V~ 50/60 Hz

Travelers

PD-5ANS, PD-6ANS

Location 1 Location 2

Page 15: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 15 12.12.18

Wiring Diagrams - Switches (cont.)

1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 ALUT-MLCensuresproperfunctionwhenLED,fluorescent,orELVloadsareused.InstalltheLUT-MLCinsidealoadfixtureorinaseparatejunctionbox

within the circuit. 3 The mechanical switch will need to be removed so the Pico remote control can be installed.4 The red wire must be connected to the load and the black wire must be connected to Line/Hot. The switch will not work if the wires are reversed.

Multi-location Installation (3 or more switches control the load)WithPicoremotecontrols(PJ2-2B-xx)andwallboxmountingadapters(PICO-WBX-ADAPT)

Pico Remote

Control and WallboxMountingAdapter 3

Pico Remote

Control and WallboxMountingAdapter 3

Pico Remote

Control and WallboxMountingAdapter 3

Pico Remote

Control and WallboxMountingAdapter 3

PD-5ANS or PD-6ANS

PD-5WS-DV

LUT-MLC2

Load

Load

Line/Hot

Line/Hot

Neutral

Neutral

GreenWhite

Green

Ground

Ground

Red 4

Black

Black

Black

Black

Black

Blue1

Blue1

120V~ 50/60 Hz

120/277V~ 50/60 Hz

Travelers

Travelers

Travelers

Travelers

PD-5WS-DV

PD-5ANS, PD-6ANS

Location 1 Location 2 Location 3

Location 1 Location 2 Location 3

Page 16: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 16 12.12.18

Wiring Diagrams - DimmersSingle Location Installation

Line / Hot

120V~ 50 / 60 Hz

Neutral

Black Red

Green

Ground

Load

Blue1, 5

White3,4

PD-10NXD or PD-5NE

PD-6WCL

1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of Caséta Wireless in-wall dimmer PRO and mechanical switch may be reversed.3 ForPD-10NXDonly,neutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 ForPD-5NE,neutralisrequired.5 Blue wire is only present on the PD-10NXD model.

Line / Hot

120V~ 50 / 60 Hz

Neutral

Black Black

Green

Ground

Load

In-Wall Dimmer

In-Wall Dimmer

Page 17: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 17 12.12.18

Multi-Location InstallationWithPicoremotecontrols(PJ2-XX-XX)andwallboxmountingadapters(PICO-WBX-ADAPT)PD-10NXD and PD-5NE

120V~ 50 / 60 Hz

Neutral

Red

Green

Ground

Load

Line / Hot

Black

Pico remote

control & wallbox

mounting adapter

Pico remote

control & wallbox

mounting adapter

In-Wall Dimmer

Black

Travelers

White3,4

Blue1, 5Travelers

120V~ 50 / 60 Hz

Neutral

Black

Green

Ground

Load

Line / Hot

Black

Pico remote

control & wallbox

mounting adapter

Pico remote

control & wallbox

mounting adapter

In-Wall Dimmer

Black

PD-6WCL

TravelersTravelers

Location 1 Location 2 Location 3

Wiring Diagrams - Dimmers (cont.)

1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of Caséta Wireless in-wall dimmer PRO and mechanical switch may be reversed.3 ForPD-10NXDonly,neutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 ForPD-5NE,neutralisrequired.5 Blue wire is only present on the PD-10NXD model.

Page 18: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 18 12.12.18

Wiring Diagrams - Dimmers (cont.)3-Way InstallationWith mechanical switch

In-Wall Dimmer2

MechanicalSwitch2

Brass

Brass

Load

Line/Hot

Neutral

GreenGround

Ground

Black

Red

Blue

120V~ 50/60 Hz

Black Jumper wire (included) White3

PD-10NXD

1 When using controls without mechanical 3-way switch, cap the blue terminal. Do not connect the blue wire to any other wiring or to ground.2 Location of in-wall dimmer and mechanical switch may be reversed.3 NeutralconnectionoptionalexceptforMLVloads,LEDdrivers,andpowermodules(PHPM-PA,PHPM-3F,andGRX-TVI).4 See Lutron P/Ns 369356 and 369355 for additional wiring diagrams.5 Blue wire is only present on the PD-10NXD model.

Installation with PHPM - Neutral required4

L/H

N

DH

In-Wall Dimmer

Neutral

Line/Hot

120V~ 60 Hz

Black Ground

GroundWhite

Green

Blue1, 5

RedPHPM

Load

Control NeutralZone In

PD-10NXD and PD-5NE

Location 1Location 2

Location 1

Page 19: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 19 12.12.18

Wiring Diagrams - Dimmers (cont.)Installation with GRX-TVI - Neutral required1

Installation with Hi-lume 1% 2-wire LED Drivers - Neutral required

L2/H

2 100

-277

V~

In-Wall Dimmer

Line/Hot

120V~ 60 Hz

Neutral

Neutral 2

Black

White

Blue 2

Ground

Green

Red

Ground

GRX-TVI

PD-10NXD and PD-5NE

PD-10NXD and PD-5NE

1 See Lutron P/N 369247 for additional wiring diagrams.2 Blue wire is only present on the PD-10NXD model.

In-Wall DimmerLine/Hot

Neutral

Black

WhiteWhite

Black

Black with White StripesGreen

Red

Red

Ground

Hi-lumeR1%2-wireLED

Driver

LEDLightEngine

Note:FormoreinformationonHi-lume1%2-wireLEDdrivers,seewww.lutron.com

Location 1

Blue 2

Page 20: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 20 12.12.18

Wiring Diagrams - Fan ControlsSingle Location Installation

PD-FSQN

PD-FSQN

Ceiling Fan

Line/Hot

Neutral

Green

Ground

Black Yellow

120V~ 50/60 Hz White

3-Way Installation (with Pico remote controls)

PJ2-2B-xxandwallboxmountingadapters(PICO-WBX-ADAPT)

BlackBlack

PD-FSQN

Pico Remote

Control and WallboxMountingAdapter 1

Ceiling Fan

Line/Hot

Neutral

GreenWhite

Ground

Yellow

120V~ 50/60 Hz

Travelers

PD-FSQNLocation 1 Location 2

1 The mechanical switch will need to be removed so the Pico remote control can be installed.

Page 21: Caséta Wireless Load Controls SPEC (369987) · ®SPECIFICATION SBMITTAL Page Job Name: Job Number: Model Numbers: Caséta Wireless Load Controls 369987d 3 12.12.18 PRO Dimmer PD-10NXD

® SPECIF ICAT ION SUBMITTAL Page

Job Name:

Job Number:

Model Numbers:

Caséta Wireless Load Controls

369987d 21 12.12.18

Colors and FinishesGloss Finishes

Due to printing limitations, colors and finishes shown cannot be guaranteed to perfectly match actual product colors.

WhiteWH

BlackBL

IvoryIV

Light AlmondLA

)Lutron,Lutron,Caséta,Pico,ClearConnect,Claro,Hi-lume,andTu-WirearetrademarksofLutronElectronicsCo.,Inc.,registeredintheU.S.andothercountries.