cast resin lv busway (ip68) taiwan busway company cast resin busway product... · tbc company...
TRANSCRIPT
TBC Company Overview
� Taiwan Busway Company, Ltd.
� Est. 2002; located in Taipei
� Brand: TBC
� Busway market leader in Taiwan, presence in China, Germany/Europe, USA. Now positioned to grow in APAC region through cooperation with EMAY International Marketing Ltd.
� Capabilities: � Experienced engineers and technical staff who participated in technical
development in Germany and the study of cast resin busway manufacturing.
� Production technicians have over 25 years experience in the manufacture of HV electrical equipment (69-345kV GIS) and LV cast resin transformers & busway.
� Participated in the research and development of insulation materials, <36kV cast resin transformers, and cast resin busway systems.
How is Cast Resin Busway different?
Conductor
Busbar Insulation & Housing = Cast Resin
Cast-resin busway
Conductor
Busbar Insulation
Housing
Sandwich busway
Advantages of Cast Resin Busway
� IEC 60529 Ingress protection rating to IP68 � Dust resistance: IP6x; Water resistance: IPx8
� IEC 60331 fire resistant rating, 750°C for 3 hours � IEC 60332 self-extinguishing insulation rating � CNS 12514 / JIS A1034 fire resistant certified – 840°C for 30 minutes � Ex.m.II.T5 explosion-proof classified to CNS 3376/IEC 60079 � High mechanical strength (IK10 impact test) to IEC 61439-1, clause 10.2.6 � Seismic certified to 0.8g � Chemical resistant
In addition to widely-known benefits of busway: � Low impedance & Low voltage drop � High short-circuit withstand strength � Compact dimensions offer substantial space savings � Easy to install & Maintenance-free � Customizable fittings available to meet special requirements
Product Overview
� Voltage: up to 1000V*
� Current ratings: � 600−6400A (Cu); � 600−4000A (Al)
� Conductor material: � Copper or Aluminum � Tin or Silver plated
� Insulation material: � Epoxy cast resin – Class F (155°C)
� IEC 60439-2 certified
* For Low Voltage (LV) range. Medium Voltage (MV) range up to 17.5kV is also available.
Product Overview
Standard bridge joint (with IP68 covers) Silicone casted joint
• casting done on site after installation
• x2 layers of IP68 (joint cover + casting)
• explosion-proof rated
� Two joint designs are available:
or
Product Features: IP68 Ingress Rating
� Meets IP68 dust-proof and water-proof requirements under IEC60529 standards.
� IP6x: Products are placed in a sealed testing chamber brought to a vacuity of 20mbar. Lime powder is then circulated in the chamber for eight hours, after which the busway and its internal connection parts show no sign of dust penetration/accumulation.
� IPx8: Products are subject to fixed power voltage and submerged with connection parts under 1M of water. Voltage pressure is steadily increased for one hour without short-circuit.
Product Features: Explosion & Impact Resistance
� Explosion-proof tested to CNS 3376.18 / IEC 60079-18 for Ex-m-II-T5 classification
� Suitable for use in hazardous application environments – � Class 1, Div 2
� IEC Zone 1 or Zone 2
� or equivalent
� Certified to IEC61439-1, clause 10.2.6 for Mechanical Impact strength IK10
Product Features: Fire Resistance
� IEC60331 � Operation for up to 3 hours at 750° C without short circuit.
� IEC60332 � self-extinguishing insulation rating
� CNS12514 & JIS A1034 � Resistance to 30 minutes of burning at 840° C without short
circuit;
� Dielectric withstand voltage test at 1.5kV/1 min, with insulation resistance test over 0.4 M-Ohm.
Classification (Peak Ground Acceleration, PGA)
5 strong 0.08g~0.25g 6 very strong 0.25g~0.4g 7 great Above 0.4g
Product Features: Seismic Certified to 0.8g
Wide Product Certifications for International Markets and Special Applications
� Busway standards:
� IEC 60439-2, IEC 60439-1, CNS 14286, JIS C8364
� China Compulsory Certification (CCC)
� Fire resistance testing:
� CNS 14286, CNS 12514, JIS C8364, JIS A1304
� Ex.m.II.T5 explosion-proof, IK10 impact test & Seismic
Vigorous Routine and In-Process Testing
• Temperature rise-testing equipment • Burning endurance testing facility • Waterproof testing equipment • Dielectric withstand voltage testing equipment • Impact testing equipment • Insulation resistance testing equipment • Thermal scans & Infrared temperature monitoring • Ultrasonic measuring equipment • Low resistance measurement • High resistance measurement • Conductivity measurement
High resistance meas. Temperature rise Low resistance meas. Dielectric withstand
Ultrasonic meas. Infrared monitoring
Thermal scans Conductivity
Infrared monitoring
Applications for Cast Resin Busway
Ideally suited for applications in harsh operating environments that require higher levels of protection.
Joint Casting Process
(1) Install joint cover
(2) Prepare casting materials (3) Pouring/casting (4) Curing & casting completed