caspa care residence, south melbourne
TRANSCRIPT
E
DN
DNUP
DN
BALC
SITTING
VOID
BED 5 BED 6 BED 7 BED 8
BED 10 BED 11 BED 12 BED 13
BED 4 BED 5 BED 6 BED 8
BED 11
BED 12
BED 13
BED 14
BED 10
BED 9
HOUSE 5
HLDGCHUTE
BED 1
BED 2
BED 3
BED 4
BED 9
ACTIVITY
OFF. TR
BED 1 BED 2 BED 3 BED 4 BED 5
DU
BED 7
BED 8 BED 9 BED 10 BED 11
BED 12 BED 13 BED 14 BED 15
HOUSE 6
HOUSE 4
WELLNESSCENTRE
LIVING
LIVING
CECI
L
STR
EET
RAGLAN STREET
NAPIER STREET
STORE
DU
EQ ST
MED
DIS.
SERV.
OFFICE
STORE
ACTIVITY
CINEMA/LIBRARY
DIS
ENS ENS ENS ENS ENS
SITTING
DINING
DINING
STORE LIFT
LIFT
PASSAGE
LOUNGE DINING
LIVINGPASSAGE
BALC
STAIR 2
STAIR 1
EXISTINGSTAIRS
ACT/PRIVATEDINING/
MEETING/BRD RM
NS
ENS
ENS ENS
ENS
ENS
ENS
ENS
ENS
ENS
ENS ENS ENS
ENS
ENS ENS ENS ENS
ENS
ENS
ENS ENS ENS ENS
ENS
ENS ENS
ENS ENS
CHUR
CH
S
TREE
T
HD CONS RM
BED 1 BED 2 BED 3
ENS ENS ENS
SERV.
OFF.
TREAT.
NSST
MED
ST
EQ. ST
BED 6
ENS
ACT
ENS
ST
SITTINGBALC
ENS ENS
ENS
LIFT LOBBY
BED 7
DIS WC
DIRTYUTILITY
CLEANLINEN
EQ ST
ST WC
PASSAGE
ENS
EXISTING FACADE
TEMPERENCEHALL
NAPIER STREETAGED CARE
MACKILLOPFAMILY
SERVICE
NOLAN COURT
3000
3000
1800
2480
SUNSHADINGSCREENS TO WESTFACING WINDOWS
SECTION OF EXISTINGHERITAGE BUILDING& FACADE TO BE RETAINED
DRIVEWAYBELOW
SUNSHADINGSCREENS TO WESTFACING WINDOWS
TOTAL SITE AREA
DEVELOPMENT SUMMARY4155 sq.m
EXISTING SITE COVERAGE (STRUCTURE)
EXISTING BUILDING- FLOOR AREA (TOTAL)- LEVEL: GROUND FLOOR- LEVEL: FIRST FLOOR
EXTERNAL PAVED SURFACES
43.0% of TOTAL SITE
3076 sq.m1785 sq.m1051 sq.m
1449 sq.m
EXISTING AREA OF SITE AVAILABLE TO PERMEABLE SURFACES 2368 sq.m
PROPOSED SITE COVERAGE 62.0 % of TOTAL SITEFLOOR AREAS
BASEMENT LEVEL (B1)- TOTAL AREA (B1)
LEVEL ONE (L1)- EXISTING HERITAGE BUILDING FRONTING NAPIER STREET- LINK STRUCTURE BETWEEN EX. NAPIER STREET BUILDING AND NEW FACILITY- NEW BUILDINGNOTE: 1050 sq.m of the 2695 sq.m is specifically bedroom accommodation.
- TOTAL AREA (L1)
LEVEL TWO (L2)- EXISTING HERITAGE BUILDING FRONTING NAPIER STREET- LINK STRUCTURE BETWEEN EX. NAPIER STREET BUILDING AND NEW FACILITY- NEW BUILDINGNOTE: 1075 sq.m of the 2670 sq.m is specifically bedroom accommodation.
- TOTAL AREA (L2)
LEVEL THREE (L3)- NEW BUILDINGNOTE: 760 sq.m of the 1670 sq.m is specifically bedroom accommodation.
- TOTAL AREA (L3)
LEVEL FOUR (L4)- NEW BUILDINGNOTE: 760 sq.m of the 1670 sq.m is specifically bedroom accommodation.
- TOTAL AREA (L4)
TOTAL FLOOR AREANOTE: 3635 sq.m – is bedroom accommodation.These calculations exclude balcony area calculations
EXTERNAL PAVED SURFACES
2300 sq.m
245 sq.m110 sq.m2340 sq.m
2695 sq.m
240 sq.m110 sq.m2320 sq.m
2670 sq.m
1670 sq.m
1670 sq.m
1635 sq.m
1635 sq.m
8670 sq.m
518 sq.m
ACCOMODATION BREAKDOWN- LEVEL ONE (L1)- LEVEL TWO (L2)- LEVEL THREE (L3)- LEVEL FOUR (L4)
TOTAL
43 BEDS44 BEDS30 BEDS29 BEDS
146 BEDS
PROPOSED AREA OF SITE AVAILABLE TO PERMEABLE SURFACES 1465 sq.mCARSPACE-ON SITE 46 CARSPACESTERRACE & BALCONY AREAS 700 sq.m
scale: date:job no: dwg no:@A1 @A3Asindicated
CaSPA Care residence, south melbourneDA110226.04.201211036
LEVEL 2 FLOOR PLAN1 : 250DA2000
1 PROPOSED LEVEL 2
PROPOSED LEVEL 1 9.94m
PROPOSED LEVEL 2 13.44m
PROPOSED BASEMENT 6.54m
PROPOSED LEVEL 3 16.94m
PROPOSED LEVEL 4 20.44m
TOP OF PARAPET WALL 23.94mTEMPERANCE HALL
MACKILLOPFAMILYSERVICES
CHURCH STREETCECIL STREET
NAPIER STREETAGED CARE DOUBLE STOREY
TERRACE HOUSE
PROPOSED SERVICES ENCLOSURE
NEW DOUBLE HEIGHT GLASS WALLSTRUCTURE TO NORTHEAST CORNER OFNAPIER STREET BUILDING. SETBACK FROMFRONT FACE OF EXISTING BUILDING
500MM HIGH CONCRETE RETAININGWALL / SEATING ELEMENT TOFRONT OF CAFE TERRACE AREA
PROPOSED STEEL FRAMED ENTRYCANOPY STRUCTURE
RETAIN EXISTING RENDERED FACADETO EXISTING NAPIER STREET BUILDING
MAKE GOOD EXISTING SLATEROOF STRUCTURE
PROPOSED AGED CAREBUILDING BEHIND EXISTINGNAPIER STREET BUILDING
PROPOSED LEVEL 1 9.94m
PROPOSED LEVEL 2 13.44m
PROPOSED BASEMENT 6.54m
PROPOSED LEVEL 3 16.94m
PROPOSED LEVEL 4 20.44m
TOP OF PARAPET WALL 23.94m
CECIL STREET CHURCH STREET
DOUBLE STOREYTERRACE HOUSE
DOUBLE STOREYTERRACE HOUSE
MACKILLOPFAMILYSERVICES
PLANT BEYOND
EXISTING ADJOININGTOWER STRUCTURE
REFRAME EXISTING HIPPEDROOF TO MATCH EXISTING
PERFORATED METALSCREENING BEHIND
EXISTING HERITAGE BUILDING & FACADETO BE RETAINED
METAL WALL CLADDING (COLORBOND)
STEEL FRAMED VERANDAH
STRUCTURES TO L3 & L4 TERRACES
PROPOSED LEVEL 1 9.94m
PROPOSED LEVEL 2 13.44m
PROPOSED BASEMENT 6.54m
PROPOSED LEVEL 3 16.94m
PROPOSED LEVEL 4 20.44m
TOP OF PARAPET WALL 23.94m
TEMPERANCE HALL
NAPIER STREET
RAGLAN STREET
DOUBLE STOREYTERRACE HOUSE
DOUBLE STOREYTERRACE HOUSE
RAGLAN STREET FRONTAGE
GRADUATED BUILDING FROMLEVEL 3 TO LEVEL 4 OF
SMOOTH & TEXTURED RENDEREDFINISHES TO MASONRY SURFACES
SMOOTH & TEXTURED RENDEREDFINISHES TO MASONRY SURFACES
DOTTED LINE INDICATEDS NAPIERSTREET BUILDING BEHIND
METAL WALL CLADDING
METAL SHADE DEVICES TO WINDOWLOCATION AS INDICATED
STEEL FRAMED ROOF STRUCTURE OVERLEVEL 4 SITTING ROOF & SIDE TERRACES
LIGHTWEIGHT INFILL BETWEEN WINDOWSAND COLORED EDGE OF SHADE DEVICE
STEEL FRAMED ROOF STRUCTURE
PLANT ENCLOSURE
scale: date:job no: dwg no:@A1 @A31 : 250
CaSPA Care residence, south melbourneDA200026.04.201211036
ELEVATIONS
1 : 250A10001 NORTH ELEVATION - NAPIER ST
1 : 250A10002 SOUTH ELEVATION - RAGLAN ST
1 : 250A10003 EAST ELEVATION - CHURCH ST