capacoustic melapor · 2020. 9. 3. · technical information no. 034 capacoustic melapor brekki...
TRANSCRIPT
Technical Information No. 034
CapaCoustic MelaporMelamine resin foam elements in different sizes,shapes and colours.
Product Description
Material DescriptionCapaCoustic Melapor elements consist of a thermosetting, flexible melamine resin foam with a filigreeopen-pored structure.
System DescriptionCapaCoustic Melapor panels may be bonded either directly as a wall covering or ceiling lining onto thestable substrate or may be positioned to the ceiling as a baffle or floating (suspended) ceiling panelusing standard T-shaped guide rails.CapaCoustic Melapor elements are excellently suitable for a later renovation, due to quick mountingand easy handling.
System Components
I. Direct bonding:
■ CapaCoustic Melapor-Kleber (Adhesive/Glue)Flexible and filled dispersion/emulsion adhesive (glue) for bonding CapaCoustic Melapor-Panels034/31-43. Product No.: 037/13, Packaging: 25 kg bucket
■ CapaCoustic Melapor-Panel The product range includes various standard formats and surfaces (see table).
Description
II. Suspended elements:
■ CapaCoustic Melapor-Baffle The product range includes various standard types (see table).
■ CapaCoustic Melapor Decken-Segel (Floating Ceiling Panel)The product range includes Concave and Convex types (see table).
■ CapaCoustic Abhang-Set (Suspension Set)Optional supplement for individual suspension of CapaCoustic Melapor Baffles.Product No.: 034/20
Technical Information No. 034
CapaCoustic Melapor Brekki (Degree of acoustic absorbtion αS / Frequency)
Type: Smooth Type: Wave
Frequency α s Third α p Octave α s Third α p Octave
100 0.08
0.20
0.04
0.10125 0.16 0.08
160 0.33 0.14
200 0.46
0.60
0.21
0.30250 0.55 0.28
315 0.82 0.45
400 0.86
0.90
0.58
0.70500 0.89 0.70
630 0.95 0.77
800 0.95
0.95
0.81
0.851000 0.97 0.88
1250 0.97 0.90
1600 0.99
1.00
0.92
0.952000 1.00 0.94
2500 1.01 0.97
3150 0.97
1.00
0.95
1.004000 0.96 0.98
5000 1.04 1.04
a w 0.90 0.60
Technical Information No. 034
CapaCoustic Melapor Panel (Degree of acoustic absorbtion αS / Frequency)
Type: Smooth Type: Wave
Frequency α s Third α p Octave α s Third α p Octave
100 0.08
0.20
0.04
0.10125 0.16 0.08
160 0.33 0.14
200 0.46
0.60
0.21
0.30250 0.55 0.28
315 0.82 0.45
400 0.86
0.90
0.58
0.70500 0.89 0.70
630 0.95 0.77
800 0.95
0.95
0.81
0.851000 0.97 0.88
1250 0.97 0.90
1600 0.99
1.00
0.92
0.952000 1.00 0.94
2500 1.01 0.97
3150 0.97
1.00
0.95
1.004000 0.96 0.98
5000 1.04 1.04
a w 0.90 0.60
Technical Information No. 034
CapaCoustic Melapor Baffle, centre distance 935 mm (Degree of acoustic absorbtion αS / Frequency)
Type: Rectangle Type: Round Type: Ellipse
Frequency α s Third α p Octave α s Third α p Octave α s Third α p Octave
100 0.07
0.10
0.06
0,10
0.05
0.10125 0.11 0.08 0.06
160 0.12 0.15 0.13
200 0.13
0.20
0.18
0,20
0.13
0.15250 0.20 0.17 0.17
315 0.32 0.23 0.22
400 0.35
0.45
0.31
0,30
0.24
0.30500 0.46 0.31 0.30
630 0.53 0.35 0.35
800 0.62
0.65
0.40
0,45
0.39
0.401000 0.62 0.45 0.44
1250 0.64 0.44 0.41
1600 0.62
0.65
0.45
0,45
0.44
0.402000 0.63 0.44 0.41
2500 0.63 0.44 0.41
3150 0.66
0.70
0.43
0,40
0.43
0.404000 0.67 0.41 0.41
5000 0.71 0.41 0.41
a w 0.30 0.30 0.30
Technical Information No. 034
CapaCoustic Melapor Baffle, centre distance 625 mm (Degree of acoustic absorbtion αS / Frequency)
Type: Rectangle Type: Round Type: Ellipse
Frequency α s Third α p Octave α s Third α p Octave α s Third α p Octave
100 0.08
0,15
0.09
0.15
0.07
0.15125 0.13 0.14 0.12
160 0.17 0.24 0.21
200 0.21
0,30
0.25
0.30
0.21
0.25250 0.30 0.29 0.30
315 0.41 0.35 0.31
400 0.49
0,60
0.43
0.45
0.35
0.45500 0.64 0.45 0.45
630 0.70 0.53 0.52
800 0.76
0,80
0.61
0.65
0.60
0.601000 0.82 0.65 0.60
1250 0.81 0.62 0.61
1600 0.82
0,80
0.64
0.65
0.62
0.602000 0.83 0.63 0.60
2500 0.81 0.63 0.61
3150 0.81
0,80
0.62
0.60
0.63
0.604000 0.81 0.62 0.60
5000 0.85 0.60 0.61
a w 0.30 0.30 0.30
Technical Information No. 034
CapaCoustic Melapor Decken-Segel / Floating Ceiling Panels, approx. 1000 mm suspendedfrom ceiling (Degree of acoustic absorbtion αS / Frequency)
Type: Concave Type: Convex
Frequency A Obj [m 2 ]Third
A Obj [m 2 ]Third
100 0.40 0.40
125 0.60 0.60
160 0.60 0.60
200 0.40 0.50
250 0.70 0.70
315 0.80 0.90
400 1.00 1.10
500 1.10 1.20
630 1.20 1.30
800 1.30 1.40
1000 1.50 1.50
1250 1.60 1.60
1600 1.60 1.70
2000 1.60 1.60
2500 1.60 1.60
3150 1.50 1.60
4000 1.50 1.50
5000 1.50 1.70
Technical Information No. 034
For rooms showing an intensive reverberation effect it is very often necessary to take reverberationregulating (suppressing) measures. In such cases the application of systems provided with sound-absorbing properties is used in order to reduce the reverberation time in all relevant rooms.For this purpose special open-porous and head-porous materials are used to reduce the penetratingsound energy.The sound energy reducing effect is achieved by the friction of air molecules (being set into oscillationby sound propagation) with pore sides within the open-pored structure.
Typical application areas are, e.g.:– Offices and call centres,– Showrooms,– Restaurants,– Schools and day-care centres,– Meeting rooms,– Training rooms or seminar rooms,– Machine shops and production halls,– Sound studios.
Field of Application
■ High sound absorption (see diagrams).■ Temperature resistance:
Long-term: -40 °C up to +180 °CShort-term: up to +200 °C
■ Heat conductivity: 0.035 W/(mK) according to DIN 52612.■ Fire behaviour classification: C-S1, d0, tested according to DIN EN 13501-1; corresponds to class
B1 according to DIN 4102-1 (with adhesive and paint coating, tested within the system).■ Bulk/green density: Approx. 10 kg/m³■ Free of mineral fibres and physiologically harmless.■ Colour: White. Coatable with CapaTrend, tinted according to Caparol 3D-plus colour fan deck
without any diminishing effect on absorption and fire behaviour.■ No electrostatic charge – does not absorb dust.
Material Properties
Product Range
I. Direct Bonding:
CapaCoustic Melapor PanelWhite or colourful coated sound absorbing element with a smooth/even or wavelike surface structure.These panels can be directly bonded onto stable substrates as wall coverings and ceiling liners.
Types that can be delivered
Type Product No.Dimensions (mm)
Units/Carton m 2 /CartonLength Width Thickness
Smooth with bevel
034/31034/32
6251250
625625
5050
16 8
Approx. 6.25Approx. 6.25
Wave
034/33 1250 625 45 22 Approx.17.19
Brekki
034/42034/43
Size M, approx. A=400/B=440Size L, approx. A=535/B=580
4024
Approx. 2.96Approx. 3.16
Technical Information No. 034
II. Suspended elements (hanging down from ceilings):
CapaCoustic Melapor BaffleWhite or colourful coated sound absorbing element in rectangular, round or elliptic shape, showing asmooth surface texture, provided with a prefab T groove. (Rails are not included in the scope ofdelivery.)
Type ProductNo.
Dimensions (mm) Units/Carton
AverageRow
Distance
m 2 /CartonLength Width Thickness
Round
034/21 1200 Ø 150 8 625 1.3
937.5 0.77
Ellipse
034/22 1200 B=172 A=110 8 625 1.3
937.5 0.77
Rectangle
034/23 1200 625 50 8 625 1.3
937.5 0.77
III. Suspended elements (hanging down from ceilings):
CapaCoustic Melapor BaffleWell-matched fixing elements for individual suspension of CapaCoustic Melapor Baffle.
Type ProductNo. Fixtures per Set Units/m 2
034/20
■ 1 unit T-shaped guide rail, length1190
■ 2 units fasteners for ceilings■ 2 units wire ropes with ballhead,
length 1500 mm■ 2 units wire rope fastener with height
adjustment and hook to hook in the T-shaped guide rail
8
IV. Suspended elements (hanging down from ceilings):
CapaCoustic Melapor Decken-Segel / Floating Ceiling PanelWhite, curved sound absorbing element, radius 2.500 mm, with a smooth surface texture,format 1020 x 1020 mm, thickness of 30 mm, fixtures included.
Type ProductNo.
Dimensions (mm)Fixtures per Panel Unit/
m 2 Length Width Thickne
ss
Concave
Fixtures for a continuously variablesuspension up to 4.5 m is includedin delivery. Perforated metal plate2 mm (aluminium) as carrier plate
on the reverse side.
1 034/51 1020 1020 Approx.
30
Convex 1
034/52 1020 1020 Approx.30
Technical Information No. 034Application
1. Substrate PreparationThe substrate must be even/planar, clean, dry, solid, sound/stable, free from all substances, that mayprevent good adhesion and should be slightly absorbent.Carefully remove dust, dirt/soiling and coats of flaking paint. Prime the substrate, if necessary.See Technical Information No. 160 for preparing suitable substrates.
2. Bonding of CapaCousticMelapor Panels
2.1 Preparation of Adhesive/GlueCapaCoustic Melapor-Kleber (adhesive/glue) is ready for use with notched trowels, without using anyfurther additives. Stir the product shortly with a suitable low-speed electric paddle (agitator). Adjust toapplication consistency with a small amount of tap (potable) water, if necessary. For lambskin rollerapplication adjust the application consistency with max. 2 % of tap water, if necessary.
2.2 Application of Adhesive/Glue
Notched trowel application:Apply an even layer of adhesive to the surface to be coated or onto the CapaCoustic Melapor Paneland then treat with a notched trowel (3x3 mm notching).
Roller application:Apply with a lambskin roller (13 mm pile height) and evenly spread to the surface to be coated or ontothe CapaCoustic Melapor Panels, until a uniform surface wetting is achieved. In both procedures theCapaCoustic Melapor Panels must be bonded without delay, when CapaCoustic Melapor adhesive(glue) is applied.Open time of adhesive (glue): Approx. 15 minutes at 20 °C.Diminished adhesion may occur with a higher substrate absorbency, higher temperature, humidity ormovement of the air due to accelerated drying of adhesive.
2.3 ConsumptionApprox. 1.5 kg/m2
2.4 Application TemperatureLower temperature limit during application and drying: +5 °C for product, substrate and ambient air.
2.5 BondingStick CapaCoustic Melapor Panels to the stable substrate. It is advisable to use a suitable pressureboard, e.g. large surface PU disc, to avoid punctiform loads which may cause partial damage ofpanels. Avoid soiling of fair-faced panels with adhesive mortar. Provide for a min. 20 mm wide shadowgap in order to achieve a convincing visual effect.
3. Suspension of Baffle Elements
3.1 CapaCoustic Melapor BafflesMounting parts (suspension attachment) for vertical or horizontal suspension from ceilings are notincluded in the scope of delivery, but are optionally deliverable. Product No.: 034/20
3.1.1 Mounting of CapaCoustic Melapor BafflesInsert the T-shaped guide rail of CapaCoustic Set 034/20 to the Baffle and suspend it from ceiling,using the wire ropes and fixing elements of the set.To avoid any slip out of position it is advisable to lock the Baffle element with a silicone blob, whenmounted.If required, the Baffles may also be suspended from the ceiling with customary T-shaped guide rails,e.g. made by USG/Donn, and using suitable fixtures (mounting accessories) and structures.
3.2 CapaCoustic Melapor Decken-Segel / Floating Ceiling PanelsThe floating ceiling panels are fixed to the ceiling at four anchorage points. Fixtures for a continuouslyvariable suspension (max. 4.5 m): Included in delivery.
4. Colour CoatingCapaCoustic Melapor elements can be coated (before or after mounting) with CapaTrend in thedesired colour shade. Preliminary sampling is required when the coat of paint should match an existingsurface in shade.
4.1 Preparation of PaintDilute CapaTrend with approx. 30 - 40 % of tap (potable) water.
Technical Information No. 034
4.2 Application of Paint CoatApply the paint coat only by high pressure or low pressure spraying method. Apply 2-3 mist coats ofdiluted paint crosswise in a distance of approx. 25 cm. Crosslinking of paint on the surface must beavoided. Airless application is not advisable.
4.3 ConsumptionApprox. 100 ml/m2 (undiluted)
4.4 Drying of ElementsAllow elements/panels to fully dry between working steps/operations. During the drying phase theyshould be supported on an even substrate or must be hung to keep shape.All elements must be thoroughly dry before they can be bonded or hung.Drying time: Min. 24 to 48 hrs., depending on temperature and relative humidity.
Advice
Workmanship:Wear clean gloves for bonding and mounting of CapaCoustic Melapor elements to avoid any soiling ofthe elements/panels.
Customization:CapaCoustic Melapor elements/panels can be cut to size with a sharp utility knife.
Dimensional Tolerances:Up to 250 mm: ± 3 mmOver 250 up to 1,000 mm: ± 5 mmOver 1,000 up to 2,000 mm: –5/+10 mm
Shrink Holes/Pores:The panels may have pores in various sizes (max. 15 mm) and frequency.
Colour Deviation:Uncoated elements may vary (slightly) in colour, due the manufacturing process.
■ CapaCoustic Melapor-Kleber (Adhesive/Glue):Keep out of reach from children. In case of contact with eyes, rinse immediately with plenty of water.Do not allow product to enter drains, waterways or soil.Further Information: See Material Safety Data Sheet (MSDS).
Please Note (Status as at Date ofPublication)
■ CapaCoustic Melapor-Kleber (Adhesive/Glue):Materials and all related packaging must be disposed of in a safe way in accordance with the fullrequirements of the local authority. Particular attention should be made to removing wastage fromsite in compliance with standard construction site procedures.In Germany: Only completely emptied containers should be given for recycling. Dispose liquidproduct residues as waste of water-soluble adhesives (glues), dried product as hardened adhesivesor via domestic waste.EWC 080410.
Disposal
■ CapaCoustic Melapor:Materials and all related packaging must be disposed of in a safe way in accordance with the fullrequirements of the local authority. Particular attention should be made to removing wastage fromsite in compliance with standard construction site procedures.In Germany: Materials and all related packaging must be disposed of in a safe way in accordancewith the full requirements of the local authority via e.g. suitable disposal site or approvedincineration plant.Panel and Baffle: EWC 120105Decken-Segel (floating ceiling panel): EWC 170904
■ CapaCoustic Melapor-Kleber (Adhesive/Glue):D1
Giscode
Tel.: (+49) 0 61 54 / 71 17 10Fax: (+49) 0 61 54 / 71 17 11e-mail: [email protected]
International Distribution: Please see www.caparol.com
Customer Service Centre
Technical Information No. 034 · Issue: December 2013All suggestions and application instructions herein are based on our latest technical experience. Due to the wide variety of individual project conditions, we cannot be held responsible for their content. These instructions do not release the purchaser/applicator from his responsibility to determine the suitability of the product in consideration of the project characteristics. These instructions are to be considered void when a new edition is released. Our general conditions of sale and delivery in theirlatest edition apply. This document is a translation of our German Technical Information No. 034 · CapaCoustic Melapor · Issued: January 2012
DAW International Business: DAW SE · P.O.B. 1264 · D-64369 Ober-Ramstadt · Tel. +49 6154 71-1274 · Fax +49 6154 71-1264 · Internet www.caparol.com