capacitacion troubleshooting pasolink
TRANSCRIPT
CAPACITACION
TROUBLESHOOTING
COMPATIBILIDAD FAMILIA PASOLINK
IDU ODU
V4
4PSK
Mx(850M)
4PSK,16Q
NEO
4-128Q/28M
XPIC/BB LRZ
IDU & ODU Compatibility
Module Replacement
IF Freq.
Mx(340M)
4PSK,16Q
NEO compact
4-16Q/28M1+0
1+1/1+0 exp.
(1)(3)
(2)(3)(4)
(1) Up to 40MB/16QAM
(2) Up to 80MB/16QAM
(3) without XPIC
(4) without BB LRZ
NEO compact
5E1-16E1
4-16Q
V3
V4
Mx
850MHz/
70MHz
Protocol
EHG
BB LRZPASO+
SDH/128Q
BB LRZ
PASO+
SDH/32Q
F/W version up
*)future release
NEO standard
5E1-STM-1
4-128Q
XPIC
INSTALACION RECOMENDADA
Recomendaciones de puestas a tierra
Puesta a tierra en la TRP
Puesta a tierra en la MDP
TROUBLE SHOOTING
DESCRIPCION GENERAL RADIOS
PASOLINK
PASOLINK V4
PASOLINK V4
CARACTERISTICAS
Ancho de banda total 34 MB.
Interfase para trafico ETHERNET.
Posibilidades de configuración 1+0 Y
1+1 (HS, SD, TP).
Modulación QPSK.
Bandas de operación
7,8,13,15,18,23,26 Y 38 Ghz.
Gestión por NMS.
Conexión de alarmas externas.
E1 a 75 O 120 OHM.
Potencia de TX ATPC O MTPC.
Fácil configuración.
PASOLINK V4
DEM invertida: Según la tabla anexa, el DEM debe ser configurado deacuerdo al tipo de ODU:
ALARMAS V4
PASOLINK MX
PASOLINK MX
CARACTERISTICAS
Ofrece capacidades de
transmisión de 5 hasta
40x2Mbps ó de 5 hasta
32x2Mbps más dos
señales 10/100 Base-
Tx. Al igual que el
equipo Pasolink V4, la
flexibilidad en su
configuración va desde
1+0 hasta 1+1 con las
opciones HS, TP y SD.
Normal Indication Values
7/8 GHz +27 to –3 dBm ±2.5 dB +21 to –3 dBm ±2.5 dB
13 GHz +25 to –5 dBm ±2.5 dB +19 to –5 dBm ±2.5 dB
15/18/23 GHz +23 to –7 dBm ±2.5 dB +17 to –7 dBm ±2.5 dB
26 GHz +20 to –10 dBm ±2.5 dB +14 to –10 dBm ±2.5 dB
38 GHz +15 to –15 dBm ±2.5 dB +9 to –15 dBm ±2.5 dB
RX Level *2
ODU PS MON *3 7-38 GHz
BER
RF BAND
TX Power *1
Item
–30 dBm
–43 V (–32 to –46 V DC)
less than 3.0E-4 to 3.0E-6
QPSK 16 QAM
PASOLINK MX
Valores típicos de enlace
*1:Depende del los valores de control de Tx.
*2:Varia dependiendo de el plan de desempeño y condiciones de
propagación.
*3:Depende de la longitud de el cable entre la IDU y la ODU
QPSK 16QAM
3.5 MHz - 10 Mbps
7 MHz 10 Mbps 20 Mbps
14 MHz 20 Mbps 40 Mbps
28 MHz 40 Mbps 80 Mbps
Frequency
Separation
Transmission Capacity
PASOLINK MX
Anchos de banda modulación y separación de canal.
PASOLINK MX
Curva de RSL para Pasolink MX
Configuración por PNMT
PASOLINK MX
PASOLINK MX
Link Performance Monitor
EB (Error Block). Se trata del número de bloques errados por
unidad de tiempo (1 seg). Se debe tener en cuenta que un código
del tipo BIP-8 constituye 1 único bloque y no 8 aislados. De este se
deriva la Tasa de Bloques Errados EBR (EB Rate).
ES (Error Second). Es un segundo donde al menos un bloques
tiene uno o más errores. Lo cual da lugar a la Tasa de segundos
con error ESR (ES Rate);
SES (Severaly Error Second). Es un segundo con más de 30% de
bloques con error o al menos un período SDP.
SDP (Severely Disturbed Period) es un período de 4 bloques
consecutivos con una BER>10-2. La persistencia de SDP durante
varios segundos puede producir la desconexión de canales
conmutados. Se desprende entonces la Tasa de segundos con
muchos errores SESR (SES Rate).
BBE (Background Block Error). Estos bloques con error no forman
parte de SES (inferior al 30%). Se obtiene la tasa de error de
bloque de fondo BBER (BBE Rate) (excluyendo los bloques con
SES y US).
US (Unavailability Second). Se cuenta desde 10 SES consecutivos
hasta 10 segundos seguidos sin SES. La indisponibilidad se
considera cuando ocurre el efecto en uno o ambos sentidos. Los
ESR, SESR o BBER solo se evalúan en estado de disponibilidad.
PASOLINK MX
Descarga de archivos de NMS y Equipment.
Login : Admin
Password : ********
12345678
PASOLINK MX
Conexión por LCT.
--- NEC PDH RADIO Ver.
1.0.27 ---
0. Logout
1. Alarm / Status
2. Performance Monitor
3. Provisioning Data
4. System Configuration
5. Inventory Data
6. Relay / House Keeping
7. Maintenance
Enter Selection :
PASOLINK MX
Configuración por LCT
--- RSL Monitor ---
08/15 15:05:01,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:02,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:03,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:04,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:05,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:06,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:07,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:08,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:09,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:10,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:11,-55,+14,-54,+14,1,1,1,0,0,0
08/15 15:05:12,-55,+14,-54,+14,1,1,1,0,0,0
PASOLINK MX
Monitoreo de RSL por LCT
Verificación de inventario por LCT
PASOLINK MX
MODULACIÓN DE
INICIACIÓNCONDICIÓN DE ALARMA
ALARMA INICIADA
INDICACIÓN DE LED EN IDU
RF CKT
Señal de entrada de FI desde IDU perdida.
IF INPUT ALM ODU
Potencia de RF de transmisión disminuye 3 a 6 dB desde nominal
TX PWR ALM ODU
ODU de 7/8/13/18/23/26/38 GHZ:
Bucle de APC del oscilador local de TX o Primer oscilador local para RX se desbloquea.
APC 1 ALMODU
ODU de 7/8/13/18/23/26/38 GHZ:
Bucle de APC del segundo oscilador local RX se desbloquea
APC 2 ALM ODU
El nivel de entrada de recepción disminuye del nivel preajustado desde el
nivel de silenciamiento.RX LEV ALM ODU
Falla la comunicación entre la IDU y ODU OPERATION ALM ODU
PASOLINK MX
PASOLINK MX
PASOLINK PLUS
PASOLINK PLUS
Descripción
El equipo Pasolink+
el cual ofrece 1 STM-
1 ó 2xSTM-1
utilizando la
transmisión co-canal
con doble
polarización y
equipado con XPIC
(Candelador de
Interferencia por
Polaridad Cruzada).
Rendimientos generales del sistema
PASOLINK PLUS
PASOLINK PLUS
Rendimientos generales del sistema
PASOLINK PLUS
IF Pasolink Plus
TIPOS DE TRPs PASOLINK PLUS
PASOLINK PLUS
Instalación de un radio Pasolink Plus Xpic (2STM1)
PASOLINK PLUS
Configuración Xpic con TP
PASOLINK PLUS
Curva de RSL típica para Pasolink Plus.
PASOLINK PLUS
Configuración y monitoreo por PNMT
--- SDH RADIO Ver. 1.4.6 ---
0. Logout
1. Alarm / Status
2. Performance Monitor
3. Provisioning Data
4. System Configuration
5. Inventory Data
6. Relay / House Keeping
7. Maintenance
PASOLINK PLUS
Configuración y monitoreo por LCT.
PASOLINK PLUS
Alarmas IF y MODEM Pasolink Plus
Alarmas MODEM y TRP
PASOLINK PLUS
PASOLINK NEOc
PASOLINK NEOc
Descripción general
Interfaces.
Modulación.
Temperatura de operación.
MDP Híbridos
TRPs
Hardware.
PASOLINK NEOc
Diagrama de flujo básico de la MDP.
PASOLINK NEOc
BW trafico TDM vs. LAN
PASOLINK NEOc
ALARM ODU ALARMS DETECTED
ODU CPU ALM /CBL Open ODU CPU Failure or IF cable open ODU
ODU ALM ODU Total alarm ODU
TX POWER ALM ODU Output power decreased ODU
TX INPUT ALM ODU TX IF Input level decreased ODU
APC ALM ODU Local Oscillator un-lock alarm ODU
RX LEVEL ALM ODU RX Level decreased ODU
LO REF ALM ODU LO reference signal loss ODU
Alarmas en la TRP
PASOLINK NEOc
Alarmas IF y MODEM.
PASOLINK NEOc
Alarm INTERFACE - PDH ALARMS
INTFC UNEQUIPPED Main interface is unequipped CTRL
TYPE MISMATCHMounted interface is different
from the configured CTRL
INTFC MODULE Main interface module failure INTFC
INPUT LOSS CH#Loss of E1 input or E3 input or WS
CH input INTFC
USAGE ERROR CH#E1 signal detected at the input of
“not used” Channel INTFC
AIS GENERATED CH# AIS generated and sent to MUX INTFC
AIS RECEIVED CH# AIS received form MUX INTFC
LAN LINK PORT1/2 LAN port Link status INTFC
LAN COLLISION PORT1/2 LAN collision occurred INTFC
LAN RDI ALM PORT 1/2 LAN RDI alarm received INTFC
Alarmas en la interfase PDH
PASOLINK NEOc
PASOLINK NEO std.
PASOLINK NEO std.
Características generales.
1 2 3 4 5 6 7 8 9 10 11 12 13
14
1. IF In/Out 5. DC 9. AUX/ALM 13. STATUS
2. XIF In/Out 6. Power Switch 10. SC IN/OUT 14. INT CARD
3. XPIC CTRL 7. LCT 11. EOW/CALL/PROTECT
4. Status LEDs 8. NMS 12. MMC
Descripción de la MDP
PASOLINK NEO std.
Descripción tarjeta CTRL y MODEM.
PASOLINK NEO std.
Diagrama de flujo de la MDP
PASOLINK NEO std.
340 MHz
140 MHz
IF Pasolink NEO std.
PASOLINK NEO std.
Baseband INT
PASOLINK NEO std.
Baseband INT
PASOLINK NEO std.
Baseband INT
PASOLINK NEO std.
Baseband INT
PASOLINK NEO std.
Upgrade NEO std.
PASOLINK NEO std.
Configuración Xpic 2xSTM1
PASOLINK NEO std.
Barra de titulo Barra de NEespecifico
Diagrama debloques
DataWindow
Login User
BarradeMenúcomún
Barradeherramientascomún
Administración y monitoreo por PNMT
PASOLINK NEO std.
Menú de aprovisionamiento del radio enlace
.
Frec. de TX y RX.
Potencia de TX.
Modulación e Interfase instalada.
Frame ID.
PASOLINK NEO std.
PASOLINK NEO std.
Menú Inventory.
PASOLINK NEO std.
Niveles RSL.
PASOLINK NEO std.
Menú Mantenance.
PASOLINK NEO std.
Menú Mantenance.
PASOLINK NEO std.
Menú de configuración.
PASOLINK NEO std.
Características de la configuración.
PASOLINK NEO std.
Umbral de Alarma de BER PDH.
Umbral de Alarma de BER SDH.
Umbrales de BER
PASOLINK NEO std.
Configuración de un puerto LAN.
PASOLINK NEO std.
Performance Monitor.
PASOLINK NEO std.
Lectura del EventLog.
PASOLINK NEO std.
Alarmas.
PASOLINK NEO std.
Indicadores interfase 48E1
PASOLINK NEO std.
Indicadores interfase 16E1+LAN.
PASOLINK NEO std.
Indicadores interfase STM1.
PASOLINK NEO std.
Alarmas generadas por la TRP.
PASOLINK NEO std.
Alarmas generadas por el MODEM.
PASOLINK NEO std.
Alarmas Interfase STM1.
PASOLINK NEO std.
Alarmas de la tarjeta CTRL.
PASOLINK NEO std.
• En los radios Nec Pasolink existen diversas versiones de Firmware que habilitan funcionalidades del radio de acuerdo con las necesidades del cliente por ejemplo versiones de Firmware para una determinada interfaz o para conectarse al gestor, un Software Key para habilitar la función XPIC en un equipo etc. De ahí la necesidad de interpretar el menú INVENTORY, para establecer si el equipo tiene habilitada o no la funcionalidad que se requiere, o si la versión de Firmware soporta la tarjeta conectada.
Versiones de Firmware y Software Key.
PASOLINK NEO std.
Visualización de versión de Firmware.
PASOLINK NEO std.
El Software Key define el
aprovisionamiento del radio y sus
aplicaciones habilitadas.
PASOLINK NEO std.
• Los puntos de posible falla se definen de acuerdo a la falla reportada
así:
• Fallas en Modulación-Demodulación.
• Fallas de Tributario, STM1 o Ethernet.
• Fallas en IF.
• Fallas en RF.
• De acuerdo a la falla reportada verificaremos la parte del enlace que
reporta el evento.
Resumen.
PASOLINK NEO std.
• Falla en Tributario, STM1 o Ethernet
• Tributario: Cuando se presentas AIS en los tributarios (AIS CH N) es necesario verificar la ruta física que los cables coaxiales conectados a la I/O Board, el equipo que genera la señal E1, generalmente es una alarma externa al radio por lo que se debe buscar externamente.
• STM1: En los STM1 las fallas mas frecuentes son LOF, LOS y E-BER es importante verificar si la alarma generada proviene del MUX (equipo de donde se origina el STM1) o de DMR (indica perdida en la sección de radio).
• Ethernet: Las alarmas LAN LINK (puerto Lan sin cable conectado), LAN COLLISION (generación de Broadcast excesivo) Y LINK LOSS FORWARDING (caída de conexión en uno de sus extremos) su origen y solución se pueden detectar fácilmente puesto que estas alarmas son locales.
Puntos de falla.
PASOLINK NEO std.
Puntos de falla.
• Fallas en IF
• Las fallas en IF se definen como problemas en la comunicación del
MODEM con la ODU y se pueden generar por los siguientes factores:
• Falla en el MODEM: Por corrosión, presencia de sulfato o daño por
descarga podremos ver en el Log del equipo alarmas relacionadas como
MODEM MODULE. Cuando el EventLog nos muestra la alarma IDU-ODU
LINK es necesario verificar la salida de voltaje DC del MODEM, pues si este
voltaje es cero debemos reemplazar el modulo.
PASOLINK NEO std.
Puntos de falla.
• Fallas en cable IF: Para identificar fallas en el cable IF debemos aclarar que la alarma que define esta falla es IDU-ODU LINK, cuando esta alarma se presenta y hemos descartado el MODEM como fuente de la misma ubicaremos su origen verificando lo siguiente:
• Conectores tipo N o TNC según el caso
• Verificar que los conectores de los extremos del cable IF no presenten cortos ya sea por humedad o por mal ensamblaje de los mismos, o que se encuentren los conectores aislados del cable.
• Cable RG8
• Verificar el correcto encintado de los conectores para que no se conviertan en punto de falla al ingresar agua al conector o al cable IF, de igual manera verificar los puntos donde el cable IF se aterriza en la torre pues debido a que se encuentra vertical es donde el encintado falla frecuentemente permitiendo el paso de agua.
PASOLINK NEO std.
Puntos de falla.
• Fallas en RF
• Se define como fallas en RF las fallas que se presentan entre la TRP del sitio
A y la TRP del sitio B incluyendo los Jumpers, Híbridos y feeder en los dos
extremos. Es importante definir por quien realiza el mantenimiento cual es la
etapa afectada pues en RF una alarma se puede presentar por varios
orígenes, por ejemplo:
• HIGH BER-LOW BER: Esta alarma indica un nivel bajo de RX que se puede
presentar por Jumpers en mal estado, Hibrido o Feeder con Humedad, TRP
atenuada, radio enlace desalineado, interferencia o desvanecimiento por
causas atmosféricas. Las alarmas RX LEVEL y THRESHOLD se pueden
originar por las mismas causas.
PASOLINK NEO std.
• La interferencia es la recepción de una señal de radio indeseada que impide el
normal funcionamiento de un canal de comunicaciones.
• La prueba mas utilizada para la detección de una interferencia en radio
Pasolink se realiza apagando uno de los extremos del punto a punto, y
conectados al radio que no se apaga en el modo LCT, monitoreamos el nivel
segundo a segundo, buscando encontrar una señal no deseada en RX, luego
se invierte apagando el extremo contrario.
Fallas por Interferencia.
PASOLINK NEO std.
GRACIAS