  • Cantilever/Gravity Walls

    Bar lists and estimates from standard design sheet

    *

  • Cantilever/Gravity WallsCantilever walls have footings forward/back of the wall (wall is essentially a cantilevered structureGravity walls have no footings *http://content.answers.com/main/content/img/McGrawHill/atchitecture/f0169-02.pnghttp://www.gravesconcrete.com/allaboutretainingwalls.htm

  • Precast*http://www.humes.com.au/ProdsServices/PrecastConcrete/PC_StorageWalls.shtml

  • Standard Design Sheets-CIP

    Cantilever/Gravity Wall Standard

    Note: Not to be used for design!!!! Handouts are old, rescinded standard sheets given solely for the educational purpose of looking at details and deriving bar lists.

    *

  • Some assumptions used for std. design

    Unit wt of earth 120 pcfUnit wt of concrete 150 pcfActive earth pressure of soil behind wall 30 psf (level surcharge)A one-ft depth of surcharge was applied above the toe of the footing.Earth fill behind the wall was assumed w/ the top of finished grade 0.75 feet below wall coping

    *

  • All retaining walls are structures -----possible failure modesOverturningSlidingEccentricity (footing can lift)Bearing pressure (footing can burrow into the soil)Rotational stabilitySettling

    *

  • Retaining Wall Failureshttp://www.youtube.com/watch?v=EXjVXaqWDLo *

  • ExampleGiven:Stem 8Min. Allowable soil pressure=1 Ton/sq ftDesign friction coefficient= 0.5Wall is 40 long*

  • ExampleFrom Design Std:Footing width: 5-2Toe Projection: 1-8T Bars #5@18H Bars #5@18D Bars #5@18B Bars #5@18Concrete Unit Quantity: 0.88 cy/lf*

  • *

  • Drawing/Bar MarksBar marks different than shown on standard drawingsE indicates epoxy coated bars*

  • *

    ************