flexible solutions

CALPEX®

The simple solution for district andlocal heating networks and efficienttransport of fluids

2nd Issue

Page 2: CALPEX Brochure

flexible solutionsflexible solutions

Your contact

3General/Benefits

4–5

6Pressure Loss

7–13Range Heating

– Dimension Pipe Heating UNO/DUO– House entry bend– Forked pipe– Fittings

14 –18Range Sanitary

– Dimension Pipe Sanitary UNO/DUO– House entry bends– Fittings

19–21Combination Range

– Dimension Pipe Heating/Sanitary QUADRIGA– House entry bends– Fittings

22–23Range T-branch

24–26Sockets Range Heating

26–28Sockets Range Sanitary

28–29Sockets without Insul.Mat.

30–32Sockets CALPEX®-

33Accessories

40–42Installation Instructions

– Stripping, pipe-preparation– Beulco-screw joint– REHAU-press connection– Fitting instruction T-piece– Fitting instruction shaft

– Installation tools, Transport, Storage– Trench dimensions, Laying, Aligning – Laying instructions, Building entry– House connection

ISO 9001ISO 14001

BRUGG Rohrsysteme GmbHAdolf-Oesterheld-Strasse 31D-31515 WunstorfTelefon +49 (0)50 31170-0Telefax +49 (0)50 [email protected]

Brugg Rohrsystem AGIndustriestrasse 39CH-5314 KleindöttingenTelefon +41 (0)56 268 78 78Telefax +41 (0)56 268 78 [email protected] der Gruppe BRUGG

System Description

34Checklist

35–39Handling

43Request per Fax

Heating/Sanitary

Plastic sheath pipe

Contents

Page 3: CALPEX Brochure

Narrow pipe trenches

As compared with plastic casing pipes,CALPEX® district heating pipes onlyrequire 60% of the previous line width.

Narrow bending radii

CALPEX® district heating pipe is fle-xible, so it can easily be adapted to vir-tually all line conditions. CALPEX® cancross over or under existing supplypipes.

Simple to lay

CALPEX® can be laid and installed in avery short time by two fitters, with noneed for special tools.

Normal commercialconnectors/compatibility

Our range of accessories offers a hugeselection, with guaranteed solutionsfor every situation. CALPEX® districtheating pipes can easily be connectedto existing district heating networks.

Composite system

CALPEX® pipes are produced in a conti-nuous length. The PUR foam and thePEX pipes form a composite which pre-vents any water from spreading alongthe medium pipe.

Specially developed forlow-temperature applications

Heating supplies, drinking water trans-port systems, waste water systems, ref-rigerating units, swimming pool tech-nology and agricultural applicationsare some of the many examples fromour comprehensive list of references.

CALPEX®versus plastic casing pipes

As compared with conventional metalpipe systems, CALPEX® offers higherresistance to chemicals; it is corrosion-free and tested for compatibility withfoods. CALPEX® has a PEXa inner pipewhich is ten times less rough thansteel, resulting in lower pressure los-ses. This means that you can selectsmaller dimensions for higher flowspeeds, so expenditure on materialsand trench costs are reduced.

No underground connections

CALPEX® district heating pipes can besupplied in rings of up to 760 m in onepiece, largely eliminating the need forconnection points underground.

3General/Benefits

Utilize your advantages:

Page 4: CALPEX Brochure

System Description

CALPEX® UNO

with heating cable channel Sanitary max. 95 °C (fluctuating) PN 10

PEXa-medium pipe

with EVOH-barrier

Corrugated polyethylene protective

sheathing

CFC-free polyurethane-foam

System Description

CALPEX® UNO

Heating/SanitaryHeating max. 95 °C (fluctuating) PN 6Sanitary max. 95 °C (fluctuating) PN 10

CALPEX® DUO

Heating/SanitaryHeating max. 95 °C (fluctuating) PN 6Sanitary max. 95 °C (fluctuating) PN 10

CALPEX® QUADRIGA

Heating/Sanitary QUADRIGA max. 95 °C (fluctuating) Heating PN 6, Sanitary PN 10

4

Page 5: CALPEX Brochure

System Description

Ref.temp. °C

20

80

20

80

20

100

20/40/60

Value

938–940 kg/m3

0,38 W/mK

26–30 N/mm2

18–20 N/mm2

600–900 N/mm2

300–400 N/mm2

1,4 ·10 E-4 1/K

2,0 ·10 E-4 1/K

130–136 °C

Better than PE-HD

Exam. norm

DIN 53479

DIN 52612

DIN 53455

DIN 53455

DIN 53457

DIN 53457

DIN 8075 B.1

Density

Thermal conductivity

Tensile strength

Tensile strength

Moduls of elasticity

Moduls of elasticity

Linear coefficient of exp.

Linear coefficient of exp.

Crystallite melting range

Chemical resistance

Carrier pipeMaterial: Cross-linked polyethylene PEX,

Basic material PE-HD,

according to DIN 16892/16893

Linking method: Peroxid (Procedure “Engel”),

term: PEXa

Life expectancy: 50 years at 70 °C permanent temperature

and permanent pressure of 7,1 bar

Oxygen-

diffusion barrier: Organic (EVOH),

< 0,10 g/m3d according to DIN 4726

Characteristics: Insensitive to aggressive water, low

pressure loss, very good resistance to

chemicals.

Pipe series according to

DIN 16893: Serie 1: PN 12,5 (at 20 °C) for Heating

Serie 2: PN 20 (at 20 °C) for Sanitary

InsulationCALPEX Heating: CFC-free, cyclopentan-blown polyurethan-

foam (PUR), with λ-value ≤ 0.0255 W/mK.

CALPEX Sanitary: CFC-free, 100 % CO2-blown polyurethan-foam (PUR),

with λ-value ≤ 0.032 W/mK.

Value

928–938 kg/m3

0,43 W/mK

Exam.norm

DIN 53479

DIN 52612

Density

Thermal conductivity

CasingMaterial: Low density polyethylene, PE-LD

seamless extruded

Task: Protection against mechanical influence

and moisture.

5

Service

Ref.temp °C

50

CALPEX Heating

value

> 60 kg/m3

≤ 0,0255 W/mK

≥ 90 %

≤ 10%

Examination

norm

DIN 53420

DIN 52612

EN 253

Density

Thermal conductivity

Closed cellular structure

Water absorption after 24 hrs.

CALPEX sanitary

value

> 60 kg/m3

≤ 0,032 W/mK

≥ 90 %

≤ 10%

Page 6: CALPEX Brochure

Range Heating

2000

100040

0

600

800

300

200

150

10020 40 60 80

1500

Druckverlust ∆p ( Pa / m )

Durc

hflu

ss m

( k

g / h

)dé

bit

( kg

/ h )

80°C

4000

030

000

2000

010

000

5000

3000

2000

1000

50020

2010

30

3050

50

100

100

200

300

300

200

500

500

1000

300

∆t 3

0°C

∆t 2

0°C

110 / 90(DN 100)

90 / 73,6(DN 80)

75 / 61,4(DN 65)

63 / 51,6(DN 50)

50 / 40,8(DN 40)

40 / 32,6(DN 32)

32 / 26,2(DN 25)

25 / 20,4(DN 20)

3,00 m / s2,00 m

/ s1,50 m / s1,00 m

/ s0,75 m / s0,50 m

/ s

0,40 m / s

0,30 m / s

Wassergeschwindigkeit

2000

100040

0

600

800

300

200

150

10020 40 60 80

1500

Druckverlust ∆p ( Pa / m )

Durc

hflu

ss m

( k

g / h

)dé

bit

( kg

/ h )

60°C

4000

030

000

2000

010

000

5000

3000

2000

1000

50020

2010

30

3050

50

100

100

200

300

300

200

500

500

1000

300

∆t 3

0°C

∆t 2

0°C

22 / 16.0(DN 16, 5/8’’)

28 / 20.0(DN 20, 3/4”)

32 / 23.3(DN 25, 1’’)

40 / 29.0(DN 32, 1 1/4’’)

50 / 36,2(DN 50, 1 1/2’’)

63 / 45.6(DN 50, 2’’)

2,00 m / s1,50 m

/ s

0,75 m / s

0,50 m / s

0,40 m / s0,30 m

/ s

1,00 m / s

3,00 m / s

Wassergeschwindigkeit

Heating

Sanitary

Pressure Loss

6

Water Velocity

Pressure Loss

Water Velocity

Pressure Loss

Flo

w R

ate

Flo

w R

ate

Page 7: CALPEX Brochure

Range Heating 7

CALPEX®-District heating pipe, Heating standard + PLUS,suitable up to 95°C and 6 bar, comprising carrier pipe of cross-linked polyethylene(PE-X) with oxygen diffusion barrier (EVOH), insulation of continuously producedCFCfree, Pentan-blown flexible polyurethane hard foam, PE-layer and a sinusoidalcorrugated, seamless extruded polyethylene (PE-LD) outer sheath, including workstesting. Supplied on drums or in coils of individual lengths up to 760 m.

Art.-Nr.

23913

23914

23915

23916

23917

Dimensions in mm

25 + 25/91

32 + 32/111

40 + 40/126

50 + 50/162

63 + 63/182

Dimensions in mm

25/ 76

32/ 76

40/ 91

40/111 Plus

50/111

63/126

75/142

90/162

110/162

110/182 Plus

Art.-Nr.

23900

23901

23903

23904

23905

23906

23907

23908

23909

23910

Dim.of coils (m)

520/760

520/760

377/560

271/380

271/380

192/280

143/220

92/144

92/144

86

Dim.of coils (m)

377/560

271/380

192/280

92/144

86

kg/m

0.90

1.00

1.39

1.90

1.97

2.60

3.39

4.56

5.69

6.38

kg/m

1.34

1.87

2.48

3.96

5.28

Single-line pipe CPX-UNO

DN

20

25

32

32

40

50

65

80

100

100

Dimensions in mm

25/ 76

32/ 76

40/ 91

40/111 Plus

50/111

63/126

75/142

90/162

110/162

110/182

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

CALPEX®-Bend 90° Heating UNO

Art.-Nr.

18623

63106

63108

24880

63110

63112

63114

63116

63466

17991

Twin-line pipe CPX-DUO

Bend CPX-UNO

Range Heating

DN

20

25

32

32

40

50

65

80

100

100

Inches 3⁄4"

1"

11⁄4"

11⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

4"

DN

20 + 20

25 + 25

32 + 32

40 + 40

50 + 50

Inches

2 x 3⁄4"

2 x 1"

2 x 11⁄4"

2 x 1 1⁄2"

2 x 2"

Inches 3⁄4"

1"

1 1⁄4"

1 1⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

4"

CALPEX®-House entry bend 90 °, Limb length 1,1 x 1,6 m Carrier pipe of cross-linked PE-X polyethylene with oxygen diffusion barrier (EVOH),insulation of 100% CFC-free polyurethane hard foam, PE-layer and PE-HDprotective sheath.

Page 8: CALPEX Brochure

Range Heating8

DN

20 + 20

25 + 25

32 + 32

40 + 40

50 + 50

Inches

2 x 3⁄4"

2 x 1"

2 x 1 1⁄4"

2 x 1 1⁄2"

2 x 2"

CALPEX®-Bend 90° Heating DUO

CALPEX®-Bend 90° Heating DUO

CALPEX®-Bend 90° Heating DUO

CALPEX®-Bend 90° Heating DUO

CALPEX®-Bend 90° Heating DUO

Art.-Nr.

24881

63124

63127

63130

17992

Bend CPX-DUO

Dimensions in mm

25 + 25/91

32 + 32/111

40 + 40/126

50 + 50/162

63 + 63/182

CALPEX®-Forked pipe, Pre-insulated connecting element between two single-line pipes and a CALPEX®-DUO-Medium pipe (PEX). Lenght 2240 mm.

PEX carrier pipe

PEX carrier pipe

PEX carrier pipe

PEX carrier pipe

PEX carrier pipe

PEX carrier pipe

2 x UNO-Pipe

25/ 76

32/ 76

40/ 91

40/111

50/111

63/126

DUO-Rohr

25 + 25/ 91

32 + 32/111

40 + 40/126

40 + 40/126 Plus

50 + 50/162 Plus

63 + 63/182 Plus

Art.-Nr.

10941

63135

63137

74652

63139

17993

Forked pipe CPX-CPXCALPEX®-UNO to CALPEX®-DUO PEX carrier pipe, suitable for

Forked pipe KMR-CPX Plastic sheathed pipe to CALPEX®-DUO St 37.0 steel carrier pipe, suitable for

Dimensions in mm

Outer diameter CALPEX® 76

Outer diameter CALPEX® 91

Outer diameter CALPEX® 111

Outer diameter CALPEX® 126

Art.-Nr.

68765

68766

68767

68768

Dimensions in mm

Outer diameter CALPEX® 142

Outer diameter CALPEX® 162

Outer diameter CALPEX® 182

Art.-Nr.

68769

68770

18075

Dimensions in mm

Outer diameter CALPEX® 76

Outer diameter CALPEX® 91

Outer diameter CALPEX® 111

Outer diameter CALPEX® 126

Art.-Nr.

67127

67129

67130

67131

Dimensions in mm

Outer diameter CALPEX® 142

Outer diameter CALPEX® 162

Outer diameter CALPEX® 182

Aquagard-Set (Primer)

Art.-Nr.

67132

67133

67128

59627

Sealing ring CPXcomprising a special section neoprene ring, suitable for

Sealing ring DOYMApressure water tight up to > 0,3 bar, comprising 1 piece DOYMA-sealing ring

type C40 for breakthrough bored or pipe liner, suitable for

DN

20

25

32

32

40

50

Inches 3⁄4"

1"

1 1⁄4"

1 1⁄4"

1 1⁄2"

2"

Steel carrier pipe

Steel carrier pipe

Steel carrier pipe

Steel carrier pipe

Steel carrier pipe

2 x UNO-Pipe

26.9/110

33.7/110

42.4/125

48.3/125

60.3/140

DUO-Pipe

26.9 + 26.9/110

33.7 + 33.7/110

42.4 + 42.4/125

48.3 + 48.3/160

60.3 + 60.3/180

Art.-Nr.

63141

63142

63144

63146

17995

DN

20

25

32

40

50

Inches 3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

In addition we advise the sealing ring DOYMA Type A40 for centering.

Page 9: CALPEX Brochure

Range Heating 9

DN

20

25

32

32

40

50

65

80

100

100

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

Art.-Nr.

69617

69624

69625

69626

69626

69627

69628

69629

69630

18078

End cap CPX for above ground connectionsas termination for house connections, comprising PE-LD

end cap for CALPEX®-UNO, suitable for

Dimensions in mm

25/76

32/76

40/91

40/111 Plus

50/111

63/126

75/142

90/162

110/162

110/182 Plus

End cap for CALPEX®-DUO, suitable for

End cap shrinking CPX for below ground connectionsheat shrinking, as termination for house connections, comprising polymerised and modi-

fied polyolefin, coated with sealing adhesive resistant to temperatures up to 125 °C.

Including temperature measuring tapes and grinding belt.

End cap for CALPEX®-UNO, suitable for

Shrinking-End cap for CALPEX®-DUO, suitable for

Inches 3⁄4"

1"

1 1⁄4"

1 1⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

4"

DN

20

25

32

32

40

50

65

80

100

100

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

Art.-Nr.

63023

61031

86300

86300

86326

86326

86326

60999

63340

63340

Dimensions in mm

25/76

32/76

40/91

40/111 Plus

50/111

63/126

75/142

90/162

110/162

110/182 Plus

Inches 3⁄4"

1"

1 1⁄4"

1 1⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

4"

DN

20 + 20

25 + 25

32 + 32

40 + 40

50 + 50

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

Art.-Nr.

69637

69634

69635

69636

18079

Dimensions in mm

25 + 25/ 91

32 + 32/111

40 + 40/126

50 + 50/162

63 + 63/182

Inches

2 x 3⁄4"

2 x 1"

2 x 1 1⁄4"

2 x 1 1⁄2"

2 x 2"

DN

20 + 20

25 + 25

32 + 32

40 + 40

50 + 50

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

PEX 6 bar

Art.-Nr.

63025

59450

59450

63424

18080

Dimensions in mm

25 + 25/ 91

32 + 32/111

40 + 40/126

50 + 50/162

63 + 63/182*

* Rubber-Endcap (not shrinkable)

Inches

2 x 3⁄4"

2 x 1"

2 x 1 1⁄4"

2 x 1 1⁄2"

2 x 2"

Page 10: CALPEX Brochure

Range Heating

Connection piece CPX, screw fitting (nut + ring type)of brass for connection to continuation pipes

PEX-Connection piece of brass with external thread, suitable for

External thread

in Inches3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

Art.-Nr.

55281

55283

55284

55285

55286

55287

55288

63320

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.9

Art.-Nr.

55294

55296

55297

55298

55299

55300

55301

63321

PEX-Connection piece with weld-on end St. 37.0 steel, suitable for

Weld-on end

in mm

26.9 x 2.65

33.7 x 2.3

42.4 x 2.6

48.3 x 2.6

60.3 x 2.9

76.1 x 3.2

88.9 x 3.2

114.3 x 3.6

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

Art.-Nr.

55310

55313

55316

55318

55320

55322

55324

63323

Coupling CPX, screw connecting piece (nut + ring type)of brass for connecting two CALPEX®-district heating pipes (without insulating material),

suitable for

Coupling CPX, reduced, screw connecting pieceof brass for connecting two CALPEX®-district heating pipes (without insulating material),

suitable for

on PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

PEX-Pipe

in mm

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

Art.-Nr.

55315

55317

55319

55321

55323

55325

63322

on PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

10

For sockets in the earth we recommend press connections.

For sockets in the earth we recommend press connections.

Page 11: CALPEX Brochure

Range Heating

Art.-Nr.

68671

68672

68673

68674

68675

68676

68677

68678

Connecting Piece CPX, Press fitting (sliding sleeve type)for connection to continuation pipes PEX-connecting piece with male thread, suitable for

PEX-connection piece with weld-on end, suitable for

Male thread

in Inches3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

2 1⁄2"

3"

4"

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

Art.-Nr.

68688

68690

68692

68694

68696

68698

68700

68702

Weld-on end

in mm

26.9 x 2.65

33.7 x 2.3

42.4 x 2.6

48.3 x 2.6

60.3 x 2.9

76.1 x 3.2

88.9 x 3.2

114.3 x 3.6

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

11

Art.-Nr.

68703

68704

68706

68708

68710

68712

68714

68716

Coupling CPX, Press fitting (sliding sleeve type)for connection two CALPEX®-district heating pipes (without insulating material),

suitable for

Coupling CPX, reduced, Press fitting (sliding sleeve type)for connection two CALPEX®-district heating pipes (without insulating material),

suitable for

PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

on PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

Art.-Nr.

68705

68707

68709

68711

68713

68715

68717

PEX-Pipe

in mm

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

110 x 10.0

on PEX-Pipe

in mm

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.7

75 x 6.8

90 x 8.2

Page 12: CALPEX Brochure

Range Heating

40

55369

55381

55386

55395

55401

55414

55421

55430

55438

63547

63556

50

55380

55394

55400

55413

55420

55429

55437

63546

63555

63

55393

55412

55419

55428

55436

63545

63554

75

55411

55427

55435

63544

63553

90

55426

63543

63552

110

63542

40

68059

68069

68074

68081

68087

68095

68102

68111

68119

68129

68138

50

68068

68080

68086

68094

68101

68110

68118

68128

68137

63

68079

68093

68100

68109

68117

68127

68136

75

68092

68108

68116

68126

68135

90

68107

68125

68134

110

68124

13

T-Piece CPX-UNO, screw connecting piecefor PEX-Pipes (without insulation) with up to multi-stage reductions, suitable for

d1/d3

22/ 22

25/ 25

28/ 28

32/ 32

32/ 28

32/ 25

40/ 40

40/ 32

50/ 50

50/ 40

63/ 63

63/ 50

75/ 75

75/ 63

90/ 90

90/ 75

110/110

110/ 90

d2: 22

55360

55366

55373

55377

55385

55418

55425

55434

55442

63551

63560

25

55362

55365

55368

55372

55376

55384

55389

55417

55424

55433

55441

63550

63559

28

55361

55364

55367

55371

55375

55383

55388

55416

55423

55432

55440

63549

63558

32

55363

55370

55374

55382

55387

55396

55402

55415

55422

55431

55439

63548

63557

Range Heating

d3

d1

d2Dimensions in mm

T-Piece CPX-UNO, screw fittingfor PEX-Pipes (without insulation) up to multi-stage reductions, suitable for

d1/d3

22/ 22

25/ 25

28/ 28

32/ 32

32/ 28

32/ 25

40/ 40

40/ 32

50/ 50

50/ 40

63/ 63

63/ 50

75/ 75

75/ 63

90/ 90

90/ 75

110/110

110/ 90

d2: 22

68050

68056

68063

68067

68073

68078

68085

68091

68099

68106

68115

68123

68133

68142

25

68051

68055

68058

68062

68066

68072

68077

68084

68090

68098

68105

68114

68122

68132

68141

28

68052

68054

68057

68061

68065

68071

68076

68083

68089

68097

68104

68113

68121

68131

68140

32

68053

68060

68064

68070

68075

68082

68088

68096

68103

68112

68120

68130

68139

d3

d1

d2

Dimensions in mm

12

For T-pieces in the earth we recommend press connections.

Page 13: CALPEX Brochure

Range Sanitary

CALPEX®-District heating pipe,suitable up to 95°C and 10 bar, comprising carrier pipe of cross-linked polyethylene(PE-X), insulation of continuously produced CFC-free, CO2- blown flexiblepolyurethane hard foam, PE-layer and a sinusoidal corrugated, seamless extrudetpolyethylene (PE-LD) outer sheath, including works testing. Supplied on drums orin coils.

22/ 76

28/ 76

32/ 76

40/ 91

50/111

63/126

Art.-Nr.

59820

59821

59805

59806

59807

59808

Length of coils (m)

360/520*

360/520*

360/520*

245/370*

200/260*

160/190*

kg/m

0.96

1.06

1.12

1.56

2.25

3.06

Lenght of coils (m)

245/370*

200/260*

160/190*

160/190*

kg/m

1.47

1.95

2.60

2.92

Single-line pipe CPX-UNO

Single-line pipe CPX-UNOwith heating tape

Twin-line pipe CPX-DUO

CALPEX®-District heating pipe, Sanitary with integral trace heating tapesuitable up to 95°C and 10 bar, comprising carrier pipe of cross-linkedpolyethylene (PE-X), self regulating integral heating tape, insulation ofcontinuously produced CFC-free, CO2-blown flexible polyurethane hard foam,PE-layer and a sinusoidally corrugated, seamless extruded polyethylene (PE-LD)outer sheath, including works testing. Supplied on drums or in coils.

Range Sanitary

Inches5⁄8"3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

DN

16

20

25

32

40

50

Nominal diameter

Dimensions in mm

28 + 22/ 91

32 + 22/111

40 + 28/126

50 + 32/126

Art.-Nr.

59809

59810

59811

59812

Inches3⁄4" + 5⁄8"

1" + 5⁄8"

1 1⁄4" + 1 3⁄4"

1 1⁄2" + 1

DN

25 + 16

32 + 16

40 + 20

50 + 25

Nominal diameter

PEX 10 bar

PEX 10 bar

PEX 10 bar

Dimensions in mm

32/111

40/126

50/126

Art.-Nr.

68004

69251

68002

Inches

1"

1 1⁄4"

1 1⁄2"

DN

25

32

40

Nominal diameter

14

* on request

* on request

* on request

Lenght of coils (m)

200/260*

160/190*

160/190*

kg/m

1.83

2.49

2.76

Page 14: CALPEX Brochure

Bend CPX-DUO

Range Sanitary 15

Bend CPX-UNO

CALPEX®-House entry bend 90°, Limb length 1.1 x 1.6 m, Carrier pipe of cross-linked polyethylene (PE-X), insulation of 100% CFC-free, polyurethane hardfoam, PE-layer and PE-HD protective sheath.

CALPEX®-Bend 90° Sanitary UNO

CALPEX®-Bend 90° Sanitary UNO

CALPEX®-Bend 90° Sanitary UNO

CALPEX®-Bend 90° Sanitary UNO

CALPEX®-Bend 90° Sanitary UNO

CALPEX®-Bend 90° Sanitary UNO

Dimensions in mm

22/ 76

28/ 76

32/ 76

40/ 91

50/111

63/126

Art.-Nr.

63103

63105

63132

63470

63471

63472

Inches5⁄8"3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

DN

16

20

25

32

40

50

Nominal diameter

Inches3⁄4" + 5⁄8"

1" + 5⁄8"

1 1⁄4" + 3⁄4"

1 1⁄2" + 1"

CALPEX®-Bend 90° Sanitary DUO

CALPEX®-Bend 90° Sanitary DUO

CALPEX®-Bend 90° Sanitary DUO

CALPEX®-Bend 90° Sanitary DUO

Art.-Nr.

63123

63126

63129

63131

DN

20 + 16

25 + 16

32 + 20

40 + 25

Nominal diameter

Dimensions in mm

Outer diameter CALPEX® 76

Outer diameter CALPEX® 91

Outer diameter CALPEX® 111

Outer diameter CALPEX® 126

Art.-Nr.

68765

68766

68767

68768

Sealing ring CPXcomprising a special section neoprene ring, suitable for

Dimensions in mm

Outer diameter CALPEX® 76

Outer diameter CALPEX® 91

Outer diameter CALPEX® 111

Outer diameter CALPEX® 126

Aquagard-Set (Primer)

Art.-Nr.

67127

67129

67130

67131

59627

Sealing ring DOYMApressure water tight up to > 0,3 bar, comprising 1 piece DOYMA-sealing ring

type C40 for carottage or pipe liner, suitable for

Less Civil Earthworks

For centering we advise supplementary the sealing ring DOYMA Type A40.

Dimensions in mm

28 + 22/ 91

32 + 22/111

40 + 28/126

50 + 32/126

Page 15: CALPEX Brochure

Heat shrinkable - end cap CPX for dry roomsheat shrinking, as termination for house connections, comprising polymerised and modi-

fied polyolefin, coated with sealing adhesive resistant to temperatures up to 125° C.

Including temperature measuring tapes and grinding belt.

End cap for CALPEX®-UNO, suitable for

Heat shrinkable - end cap for CALPEX®-DUO, suitable for

Range Sanitary16

Inches5/8"3/4"

1"⁄

1 1/4"

1 1/2"

2"

Dimensions in mm

22/ 76

28/ 76

32/ 76

40/ 91

50/111

63/126

Art.-Nr.

63023

61031

61031

86300

86326

86326

Nominal diameter

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

16

20

25

32

40

50

Inches3/4" + 5/8"

1" + 5/8"

1 1/4" + 1 3/4"

1 1/2" + 1"

Dimensions in mm

28 + 22/ 91

32 + 22/111

40 + 28/126

50 + 32/126

Art.-Nr.

63025

59450

59450

59450

Nominal diameter

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

20 + 16

25 + 16

32 + 20

40 + 25

Inches5⁄8"3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

Art.-Nr.

69616

69617

69624

69625

69626

69627

End cap CPX for dry roomsas termination for house connections, suitable for: PE-LD end cap

for CALPEX®-UNO, suitable for

Dimensions in mm

22/ 76

28/ 76

32/ 76

40/ 91

50/111

63/126

End cap CALPEX®-DUO, suitable for

Inches

1"

1 1⁄4"

1 1⁄2"

Dimensions in mm

32/111

40/126

50/126

Art.-Nr.

69619

69620

69621

End cap for CALPEX®-UNO with heating tape channel, suitable for

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

16

20

25

32

40

50

Nominal diameter

Inches3⁄4" + 5⁄8"

1" + 5⁄8"

1 1⁄4" + 1 3⁄4"

1 1⁄2" + 1"

Art.-Nr.

69639

69640

69641

69642

Dimensions in mm

28 + 22/ 91

32 + 22/111

40 + 28/126

50 + 32/126

PEX 10 bar

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

20 + 16

25 + 16

32 + 20

40 + 25

Nominal diameter

Nominal diameter

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

25

32

40

Page 16: CALPEX Brochure

Range Sanitary 17

Inches

1"

1 1⁄4"

1 1⁄2"

Dimensions in mm

32/111

40/126

50/126

Art.-Nr.

86300

86300

86326

Shrinkable End cap for CALPEX®-UNO with heating band channel, suitable for

PEX 10 bar

PEX 10 bar

PEX 10 bar

DN

25

32

40

Nominal diameter

External thread

Inches3⁄4"3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Art.-Nr.

55280

55282

55289

55290

55291

55292

Connection piece CPX, screwfor connection to continuation pipes

PEX-connection piece of brass with external thread, suitable for

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

Art.-Nr.

55293

55295

PEX-Connection piece with weld-on end St. 37.0 steel, suitable for

Weld-on end

in mm

26.9 x 2.65

26.9 x 2.65

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Art.-Nr.

55309

55311

55326

55328

55330

55332

Coupling CPX, equal, screw connecting pieceof brass for connecting two CALPEX® district heating pipes (without insulating material),

suitable for

PEX-Pipe

in mm

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Art.-Nr.

55312

55327

55329

55331

55333

Coupling CPX, reduced, screw connecting pieceof brass for connecting two CALPEX® district heating pipes (without insulating material),

suitable for

Application: For use sanitary pipes in the range of heating.

on PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

on PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

For sockets in the earth we advise press connections.

For sockets in the earth we advise press connections.

Page 17: CALPEX Brochure

External thread

Inches3⁄4"3⁄4"

1"

1 1⁄4"

1 1⁄2"

2"

Art.-Nr.

68679

68680

68681

68682

68683

68684

Connection piece CPX, press connectionfor connection to continuation pipes

PEX-connection piece with external thread, suitable for

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

Weld-on end

in mm

26.9 x 2.65

26.9 x 2.65

Art.-Nr.

68685

68686

PEX-connection piece with weld-on end, suitable for

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Art.-Nr.

68718

68719

68721

68723

68725

68727

Coupling CPX, equal, press connectionfor connecting two CALPEX®-district heating pipes (without insulating material), suitable for

PEX-Pipe

in mm

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Art.-Nr.

68720

68722

68724

68726

68728

Coupling CPX, reduced, press connectionfor connecting two CALPEX®-district heating pipes (without insulating material), suitable for

Range Sanitary18

Application: For use sanitary pipes in the range of heating.

on PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

on PEX-Pipe

in mm

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

Page 18: CALPEX Brochure

Quatro Range Heating/Sanitary 19

Art.-Nr.

71900

70870

71901

71902

Delivery length (m)

110/140*

110/140*

110/140*

80/ 90*

kg/m

3.25

3.39

3.41

4.15

Quadro pipeline CPX-QUADRIGA

CALPEX®-District heating pipe Heating and Sanitary, suitable up to max. 95 °C(fluctuating) and 6 bar (Heating), 10 bar (Sanitary), suitable for:Medium Pipe of cross-linked polyethylene (PEX) with oxygen-diffusion barrier(heating), insulation of continuously produced CFC-free, CO2 blown flexible poly-urethane-hard foam, PE-layer and a sinusoidal corrugated, seamless extruded poly-ethylene (PE-LD) outer sheath, including works testing. Supplied on drums or incoils.

Combi-Set Heating/Sanitary

Bend CPX-QUADRIGACALPEX®-Bend 90° Heating and Sanitary QUADRIGA

CALPEX®-House entry bend 90°, limb length 1,1 x 1,6 m, carrier pipe of cross-linked PEX polyethylene with oxygen diffusion barrier (heating), insulation of100% CFC-free, polyurethane hard foam, PE-layer and PE-HD protective sheath.

Dimensions in mm

Outer diameter CALPEX® 142

Outer diameter CALPEX® 162

Art.-Nr.

68769

68770

Sealing ring CPXcomprising a special section neoprene ring, suitable for

Dimensions in mm

Outer diameter CALPEX® 142

Outer diameter CALPEX® 162

Aquagard-Set (Primer)

Art.-Nr.

67132

67133

59627

Sealing ring DOYMApressure water tight up to > 0,3 bar, comprising a special section neoprene ring and two

clamping clips, suitable for

Nominal diameter

DN

H = 20 + 20, S = 20 + 16

H = 25 + 25, S = 20 + 16

H = 25 + 25, S = 25 + 16

H = 32 + 32, S = 32 + 20

Dimensions in mm

H = 25 + 25, S = 28 + 22, A = 142

H = 32 + 32, S = 28 + 22, A = 142

H = 32 + 32, S = 32 + 22, A = 142

H = 40 + 40, S = 40 + 28, A = 162

Inches

H = 3⁄4"+ 3⁄4", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 1"+ 5⁄8"

H = 1 1⁄4"+ 1 1⁄4", S = 1 1⁄4"+ 3⁄4"

Art.-Nr.

72400

72401

72402

72403

Nominal diameter

DN

H = 20 + 20, S = 20 + 16

H = 25 + 25, S = 20 + 16

H = 25 + 25, S = 25 + 16

H = 32 + 32, S = 32 + 20

Dimensions in mm

H = 25 + 25, S = 28 + 22, A = 143

H = 32 + 32, S = 28 + 22, A = 143

H = 32 + 32, S = 32 + 22, A = 143

H = 40 + 40, S = 40 + 28, A = 163

Inches

H = 3⁄4"+ 3⁄4", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 1"+ 5⁄8"

H = 1 1⁄4"+ 1 1⁄4" S = 1 1⁄4"+ 3⁄4"

In addition we advise the sealing ring DOYMA Type A40

Page 19: CALPEX Brochure

Heating page10, Sanitary page 17

Heating page 11, Sanitary page 18

Quatro Range Heating/Sanitary

Shrink-end cap CPX for below ground connectionsheat shrinking, as termination for house connections, comprising polymerised and modi-

fied polyolefin, coated with sealing adhesive resistant to temperatures up to 125 °C.

Including temperature measuring tapes and grinding belt.

End cap for CALPEX®-QUADRIGA, suitable for

PEX-Connection piece with external thread

PEX-Connection piece with weld-on end St. 37.0 steel

Connecting piece CPX, compression (nut + ring type)for connection to continuation pipes

20

PEX-Connection piece with external thread

PEX-Connection piece with weld-on fitting St. 37.0 steel

Connection piece CPX, press connection (sliding sleeve type)for connection to continuation pipes

S = 10 bar

S = 10 bar

S = 10 bar

S = 10 bar

Art.-Nr.

73840

73841

73842

73843

PEX H = 6 bar

PEX H = 6 bar

PEX H = 6 bar

PEX H = 6 bar

Nominal diameter

DN

H = 20 + 20, S = 20 + 16

H = 25 + 25, S = 20 + 16

H = 25 + 25, S = 25 + 16

H = 32 + 32, S = 32 + 20

Dimensions in mm

H = 25 + 25, S = 28 + 22, A = 142

H = 32 + 32, S = 28 + 22, A = 142

H = 32 + 32, S = 32 + 22, A = 142

H = 40 + 40, S = 40 + 28, A = 162

Inches

H = 3⁄4"+ 3⁄4", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 1"+ 5⁄8"

H = 1 1⁄4"+ 1 1⁄4", S = 1 1⁄4"+ 3⁄4"

End cap CPX for above ground connectionsas termination for house connections, comprising PE-LD

End cap for CALPEX®-QUADRIGA, suitable for

Dimensions in mm

H = 25 + 25, S = 28 + 22, A = 142

H = 32 + 32, S = 28 + 22, A = 142

H = 32 + 32, S = 32 + 22, A = 142

H = 40 + 40, S = 40 + 28, A = 162

Nominal diameter

DN

H = 20 + 20, S = 20 + 16

H = 25 + 25, S = 20 + 16

H = 25 + 25, S = 25 + 16

H = 32 + 32, S = 32 + 20

Inches

H = 3⁄4"+ 3⁄4", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 3⁄4"+ 5⁄8"

H = 1"+ 1", S = 1"+ 5⁄8"

H = 1 1⁄4"+ 1 1⁄4", S = 1 1⁄4"+ 3⁄4"

S = 10 bar

S = 10 bar

S = 10 bar

S = 10 bar

Art.-Nr.

73780

73781

73782

73783

PEX H = 6 bar

PEX H = 6 bar

PEX H = 6 bar

PEX H = 6 bar

Page 20: CALPEX Brochure

Quatro Range Heating/Sanitary 21

CALPEX®-Coupling, equal

CALPEX®-Coupling, reduced

Coupling CPX, equal/reduced, press connectionfor connecting two CALPEX® district heating pipes (without insulating material)

For the system CALPEX®-QUADRIGA we advise connection-pieces

and couplings with press connection.

Heating page 10, Sanitary page 17

Heating page 11, Sanitary page 18

CALPEX®-Coupling, equal

CALPEX®-Coupling, reduced

Coupling CPX, equal/reduced, screwof brass for connecting two CALPEX® district heating pipes (without insulating material)

Customised Pipe lengths

For sockets in the earth we advise press connections.

Page 21: CALPEX Brochure

CPX-T-piece installation setInsulating material: PUR-foam package, CALPEX®-UNO (DUO with press connection) T-piece-

set with GFK-hemispheres, comprising: two GFK-hemispheres of fracture-proof fibre-glass

polyester compound (inc. reducing rings at the relevant reductions), brass screw valve,

installation seal, set of screws and a PUR-foam-cartridge, suitable for outer

diameters:

d1/d3

76/ 76

91/ 91

91/ 76

111/111

111/ 91

126/126

126/111

142/142

142/126

162/162

162/142

162/126

182/182

182/162

182/142

d2: 76

63009

63013

63014

63016

63018

63021

63024

63045

63049

63033

63037

91

63010

63017

63019

63020

63022

63044

63048

63032

63036

67992

18005

18011

18017

111

63029

63027

63028

63043

63047

63031

63035

67991

18004

18010

18016

126

63026

63042

63046

63030

63034

67990

18003

18009

18015

162

63050

18001

18007

18013

182

18000

18006

18012

142

63053

63051

63052

18002

18008

18014

Range T-branch

d1

d3

d2

22 Range T-branch

Dimensions in mm

More dimensions of T-pieces on request.

Page 22: CALPEX Brochure

Range T-branch 23

CPX-T-piece installation setCALPEX®-T-piece installation set, without insulating material, CALPEX®-UNO (DUO with

press connection) T-piece installation set with GFK-hemispheres suitable for: two GFK-

hemispheres of fracture-proof fibre-glas polyester compound (incl. reducing rings at the

relevant reductions), brass screw valve, seal tape and screw valve, suitable for outer dia-

meters:

d1/d3

76/ 76

91/ 91

91/ 76

111/111

111/ 91

126/126

126/111

142/142

142/126

162/162

162/142

182/182

182/162

182/142

d2: 76

63430

63432

63433

63436

63438

63442

63445

63450

63454

63460

63465

91

63431

63435

63437

63441

63444

63449

63453

63459

63464

18023

18029

18035

111

63434

63440

63443

63448

63452

63458

63463

18022

18028

18034

126

63439

63447

63451

63457

63462

18021

18027

18033

162

63455

18019

18025

18031

182

18018

18024

18030

142

63446

63456

63461

18020

18026

18032

Modular system

Dimensions in mm

Page 23: CALPEX Brochure

Socket Range Heating

Dimensions in mm

25/ 76 auf 25/ 76

25/ 76 auf 32/ 76

25/ 76 auf 32/ 91

32/ 76 auf 32/ 76

32/ 76 auf 40/ 91

32/ 91 auf 32/ 91

32/ 91 auf 40/111

40/ 91 auf 32/ 76

40/ 91 auf 40/ 91

40/ 91 auf 50/111

40/111 auf 40/111

40/111 auf 50/111

50/111 auf 40/ 91

50/111 auf 50/111

50/111 auf 63/126

63/126 auf 63/126

63/126 auf 75/142

75/142 auf 75/142

75/142 auf 90/162

90/162 auf 90/162

90/162 auf 110/162

110/162 auf 110/162

110/162 auf 110/182

110/182 auf 110/182

Art.-Nr.

63218

63218

63223

63218

63223

63205

63207

63223

63205

63207

63206

63206

63207

63206

63209

63208

63213

63212

63215

63214

63214

63214

63397

18100

Connecting socket-Set CPX-CPX for CALPEX®-Uno Heating with PUR-foam package, suitable for

CALPEX®-Connecting socket, type CALPEX®-CALPEX®

for pipes 6 bar, with insulating material: foam package of polyurethane foam orPE-foam, comprising: PEH-socket pipe (reduced at one side for reducing sockets),two PE-shrinking hoses, foam package of polyurethane foam or PE-foam and agrinding belt.

24 Socket Range Heating

Page 24: CALPEX Brochure

Socket Range Heating 25

Dimensions in mm

2 x 25/ 91 auf 2 x 25/ 91

2 x 25/ 91 auf 2 x 32/111

2 x 32/111 auf 2 x 32/111

2 x 32/111 auf 2 x 40/126

2 x 32/111 auf 2 x 28/111

2 x 40/126 auf 2 x 40/126

2 x 40/126 auf 2 x 50/162

2 x 50/162 auf 2 x 50/162

2 x 50/162 auf 2 x 63/182

2 x 63/182 auf 2 x 63/182

Art.-Nr.

63205

63207

63206

63209

63206

63208

63291

63214

63397

18100

Connecting socket-set CPX-CPX for CALPEX®-Duo Heating with PUR-foam, suitable for

Dimensions in mm

25/ 76 auf 25/ 76

25/ 76 auf 32/ 76

25/ 76 auf 32/ 91

32/ 76 auf 32/ 76

32/ 76 auf 40/ 91

32/ 91 auf 32/ 91

32/ 91 auf 40/111

40/ 91 auf 32/ 76

40/ 91 auf 40/ 91

40/ 91 auf 50/111

40/111 auf 40/111

40/111 auf 50/111

50/111 auf 40/ 91

50/111 auf 50/111

50/111 auf 63/126

63/126 auf 63/126

63/126 auf 75/142

75/142 auf 75/142

75/142 auf 90/162

90/162 auf 90/162

90/162 auf 110/162

110/162 auf 110/162

110/162 auf 110/182

110/182 auf 110/182

Art.-Nr.

63171

63171

63175

63171

63175

63155

63177

63175

63174

63177

63176

63176

63177

63176

63179

63178

63181

63180

63183

63166

63531

63530

18105

18106

Connecting socket-set CPX-CPX for CALPEX®-Uno Heating with PE-foam, suitable for

Page 25: CALPEX Brochure

Dimensions in mm

22/ 76 to 22/ 76

28/ 76 to 28/ 76

28/ 76 to 32/ 76

32/ 76 to 32/ 76

32/ 76 to 40/ 91

40/ 91 to 40/ 91

40/ 91 to 50/111

50/111 to 50/111

50/111 to 63/126

63/126 to 63/126

Art.-Nr.

63218

63218

63218

63218

63223

63205

63207

63206

63209

63208

Connecting socket-set CPX-CPX for CALPEX®-Uno Sanitary with PUR-foam package, suitable for

CALPEX®-Connecting socket-set, type CALPEX®-CALPEX®

for pipes 10 bar, with insulating material: foam package of polyurethane or PE-foam, suitable for: one PEH-socket pipe (reduced at one side for reducingsockets), two PE-shrinking hoses, foam package of polyurethane foam or PE-foam and a grinding belt.

Dimensions in mm

22/ 76 to 22/ 76

28/ 76 to 28/ 76

28/ 76 to 32/ 76

32/ 76 to 32/ 76

32/ 76 to 40/ 91

40/ 91 to 40/ 91

40/ 91 to 50/111

50/111 to 50/111

50/111 to 63/126

63/126 to 63/126

Art.-Nr.

63168

63170

63172

63171

63175

63174

63177

63176

63179

63178

Connecting socket-set CPX-CPX for CALPEX®-Uno Sanitary with PE-foam, suitable for

Socket Range Sanitary

Socket Range Heating/Sanitary26

Dimensions in mm

2 x 25/ 91 to 2 x 25/ 91

2 x 25/ 91 to 2 x 32/111

2 x 32/111 to 2 x 32/111

2 x 32/111 to 2 x 40/126

2 x 32/111 to 2 x 28/111

2 x 40/126 to 2 x 40/126

2 x 40/126 to 2 x 50/162

2 x 50/162 to 2 x 50/162

2 x 50/162 to 2 x 63/182

2 x 63/182 to 2 x 63/182

Art.-Nr.

63264

63266

63255

63259

63255

63258

63261

63250

18107

18108

Connecting socket-set CPX-CPX for CALPEX®-Duo Heating with PE-foam, suitable for

Page 26: CALPEX Brochure

Socket Range Sanitary 27

Art.-Nr.

63205

63207

63206

63209

63208

63208

63208

Connecting socket-set CPX-CPXfor CALPEX®-Duo Sanitary with PUR-foam package, suitable for

Art.-Nr.

63264

63266

63265

63268

63267

63270

63269

Connecting socket-set CPX-CPXfor CALPEX®-Duo Sanitary with PE-foam, suitable for

Dimensions in mm

32/111 to 32/111

32/111 to 40/126

40/126 to 40/126

40/126 to 50/126

50/126 to 50/126

Art.-Nr.

63206

63209

63208

63208

63208

Connecting socket-set CPX-CPXfor CALPEX®-Uno Sanitary with heating cable channel and PUR-foam package, suitable for

Dimensions in mm

28 + 22/ 91 to 28 + 22/ 91

28 + 22/ 91 to 32 + 22/111

32 + 22/111 to 32 + 22/111

32 + 22/111 to 40 + 28/126

40 + 28/126 to 40 + 28/126

40 + 28/126 to 50 + 32/126

50 + 32/126 to 50 + 32/126

Dimensions in mm

28 + 22/91 to 28 + 22/ 91

28 + 22/91 to 32 + 22/111

32 + 22/111 to 32 + 22/111

32 + 22/111 to 40 + 28/126

40 + 28/126 to 40 + 28/126

40 + 28/126 to 50 + 32/126

50 + 32/126 to 50 + 32/126

Page 27: CALPEX Brochure

Art.-Nr.

63156

63159

63158

63161

63160

Connecting socket-set CPX-CPXfor CALPEX®-Uno Sanitary with heating cable channel and PE-foam, suitable for

Ø Casing in mm

76 to 76

76 to 91

91 to 91

91 to 111

111 to 111

111 to 126

126 to 126

126 to 142

142 to 142

142 to 162

162 to 126

162 to 162

162 to 182

182 to 182

Art.-Nr.

63079

63090

63080

63092

63081

63095

63082

63098

63083

63089

63099

63084

63242

18109

Connecting socket-set CPX-CPXfor CALPEX®-Uno Heating/Sanitary without insulating material, suitable for

Dimensions in mm

32/111 to 32/111

32/111 to 40/126

40/126 to 40/126

40/126 to 50/126

50/126 to 50/126

High Economy

Sockets without Insulating MaterialCALPEX®-Connecting socket-set, type CALPEX®-CALPEX®

for pipes 6 and 10 bar, without insulating material, comprising: one PEH-socketpipe (reduced at one side for reducing sockets), two PE-shrinking hoses and agrinding belt.

Socket Range Sanitary/without Insulating Material28

Page 28: CALPEX Brochure

Sockets Range without Insulating Material 29

Ø Casing in mm

91 to 91

91 to 111

111 to 111

111 to 126

126 to 126

126 to 142

142 to 142

142 to 162

162 to 126

162 to 162

162 to 182

182 to 182

Art.-Nr.

63080

63092

63081

63095

63082

63098

63083

63089

63099

63084

63242

18109

Connecting socket-set CPX-CPXfor CALPEX®-Duo Heating/Sanitary without insulating material, suitable for

Rapid Installation

Page 29: CALPEX Brochure

Angaben in mm

CALPEX® 22/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 22/ 76 to plastic sheath pipe 26.9/110

CALPEX® 22/ 76 to plastic sheath pipe 26.9/125

CALPEX® 25/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 25/ 76 to plastic sheath pipe 26.9/110

CALPEX® 25/ 76 to plastic sheath pipe 26.9/125

CALPEX® 28/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 28/ 76 to plastic sheath pipe 26.9/110

CALPEX® 28/ 76 to plastic sheath pipe 26.9/125

CALPEX® 32/ 76 to plastic sheath pipe 33.7/ 90

CALPEX® 32/ 76 to plastic sheath pipe 33.7/110

CALPEX® 32/ 76 to plastic sheath pipe 33.7/125

CALPEX® 32/ 91 to plastic sheath pipe 33.7/ 90

CALPEX® 32/ 91 to plastic sheath pipe 33.7/110

CALPEX® 32/ 91 to plastic sheath pipe 33.7/125

CALPEX® 40/ 91 to plastic sheath pipe 42.4/110

CALPEX® 40/ 91 to plastic sheath pipe 42.4/125

CALPEX® 40/ 91 to plastic sheath pipe 42.4/140

CALPEX® 40/111 to plastic sheath pipe 42.4/110

CALPEX® 40/111 to plastic sheath pipe 42.4/125

CALPEX® 40/111 to plastic sheath pipe 42.4/140

CALPEX® 50/111 to plastic sheath pipe 48.3/110

CALPEX® 50/111 to plastic sheath pipe 48.3/125

CALPEX® 50/111 to plastic sheath pipe 48.3/140

CALPEX® 63/126 to plastic sheath pipe 60.3/125

CALPEX® 63/126 to plastic sheath pipe 60.3/140

CALPEX® 63/126 to plastic sheath pipe 60.3/160

CALPEX® 75/142 to plastic sheath pipe 76.1/140

CALPEX® 75/142 to plastic sheath pipe 76.1/160

CALPEX® 75/142 to plastic sheath pipe 76.1/180

CALPEX® 90/162 to plastic sheath pipe 88.9/160

CALPEX® 90/162 to plastic sheath pipe 88.9/180

CALPEX® 90/162 to plastic sheath pipe 88.9/200

CALPEX® 110/162 to plastic sheath pipe 114.3/200

CALPEX® 110/162 to plastic sheath pipe 114.3/225

CALPEX® 110/162 to plastic sheath pipe 114.3/250

CALPEX® 110/182 to plastic sheath pipe 114.3/200

CALPEX® 110/182 to plastic sheath pipe 114.3/225

CALPEX® 110/182 to plastic sheath pipe 114.3/250

Art.-Nr.

63223

63398

63414

63223

63398

63414

63223

63398

63414

63223

63398

63414

63205

63207

63402

63207

63402

63418

63206

63209

63419

63206

63209

63419

63208

63213

63291

63212

63215

63421

63214

63397

63413

63413

63538

63539

18111

18112

18113

Connecting socket-set CPX-KMRfor CALPEX®-Uno Heating/Sanitary with PUR-foam package, suitable for

Sockets CALPEX®-Plastic SheathCALPEX®-connecting socket-set, type CALPEX®-plastic sheath pipe (KMR)for pipes 6 and 10 bar, with insulating material: foam package of polyurethane foamor PE-foam, comprising: one PEH-socket pipe (reduced at one side for reducingsockets), two PE-shrinking hoses, foam package of polyurethane foam or PE-foamand a grinding belt.

30 Muffen zu Kunststoffmantelrohr

Page 30: CALPEX Brochure

Range Sanitary 31

Pipe

Dimensions in mm

CALPEX® 22/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 22/ 76 to plastic sheath pipe 26.9/110

CALPEX® 22/ 76 to plastic sheath pipe 26.9/125

CALPEX® 25/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 25/ 76 to plastic sheath pipe 26.9/110

CALPEX® 25/ 76 to plastic sheath pipe 26.9/125

CALPEX® 28/ 76 to plastic sheath pipe 26.9/ 90

CALPEX® 28/ 76 to plastic sheath pipe 26.9/110

CALPEX® 28/ 76 to plastic sheath pipe 26.9/125

CALPEX® 32/ 76 to plastic sheath pipe 33.7/ 90

CALPEX® 32/ 76 to plastic sheath pipe 33.7/110

CALPEX® 32/ 76 to plastic sheath pipe 33.7/125

CALPEX® 32/ 91 to plastic sheath pipe 33.7/ 90

CALPEX® 32/ 91 to plastic sheath pipe 33.7/110

CALPEX® 32/ 91 to plastic sheath pipe 33.7/125

CALPEX® 40/ 91 to plastic sheath pipe 42.4/110

CALPEX® 40/ 91 to plastic sheath pipe 42.4/125

CALPEX® 40/ 91 to plastic sheath pipe 42.4/140

CALPEX® 40/111 to plastic sheath pipe 42.4/110

CALPEX® 40/111 to plastic sheath pipe 42.4/125

CALPEX® 40/111 to plastic sheath pipe 42.4/140

CALPEX® 50/111 to plastic sheath pipe 48.3/110

CALPEX® 50/111 to plastic sheath pipe 48.3/125

CALPEX® 50/111 to plastic sheath pipe 48.3/140

CALPEX® 63/126 to plastic sheath pipe 60.3/125

CALPEX® 63/126 to plastic sheath pipe 60.3/140

CALPEX® 63/126 to plastic sheath pipe 60.3/160

CALPEX® 75/142 to plastic sheath pipe 76.1/140

CALPEX® 75/142 to plastic sheath pipe 76.1/160

CALPEX® 75/142 to plastic sheath pipe 76.1/180

CALPEX® 90/162 to plastic sheath pipe 88.9/160

CALPEX® 90/162 to plastic sheath pipe 88.9/180

CALPEX® 90/162 to plastic sheath pipe 88.9/200

CALPEX® 110/162 to plastic sheath pipe 114.3/200

CALPEX® 110/162 to plastic sheath pipe 114.3/225

CALPEX® 110/162 to plastic sheath pipe 114.3/250

CALPEX® 110/182 to plastic sheath pipe 114.3/200

CALPEX® 110/182 to plastic sheath pipe 114.3/225

CALPEX® 110/182 to plastic sheath pipe 114.3/250

Art.-Nr.

63332

63348

63364

63332

63348

63364

63334

63350

63366

63335

63351

63367

63325

63341

63357

63336

63352

63368

63326

63342

63358

63337

63353

63369

63338

63354

63370

63339

63355

63371

63331

63347

63363

63534

63535

63536

18117

18118

18119

Connecting socket-set CPX-KMRfor CALPEX®-Uno Heating/Sanitary with PE-foam, suitable for

Page 31: CALPEX Brochure

ø Casing in mm

CALPEX® 76 to plastic sheath pipe 90

CALPEX® 76 to plastic sheath pipe 110

CALPEX® 76 to plastic sheath pipe 125

CALPEX® 91 to plastic sheath pipe 90

CALPEX® 91 to plastic sheath pipe 110

CALPEX® 91 to plastic sheath pipe 125

CALPEX® 91 to plastic sheath pipe 140

CALPEX® 111 to plastic sheath pipe 90

CALPEX® 111 to plastic sheath pipe 110

CALPEX® 111 to plastic sheath pipe 125

CALPEX® 111 to plastic sheath pipe 140

CALPEX® 126 to plastic sheath pipe 110

CALPEX® 126 to plastic sheath pipe 125

CALPEX® 126 to plastic sheath pipe 140

CALPEX® 126 to plastic sheath pipe 160

CALPEX® 142 to plastic sheath pipe 125

CALPEX® 142 to plastic sheath pipe 140

CALPEX® 142 to plastic sheath pipe 160

CALPEX® 142 to plastic sheath pipe 180

CALPEX® 162 to plastic sheath pipe 140

CALPEX® 162 to plastic sheath pipe 160

CALPEX® 162 to plastic sheath pipe 180

CALPEX® 162 to plastic sheath pipe 200

CALPEX® 162 to plastic sheath pipe 225

CALPEX® 162 to plastic sheath pipe 250

CALPEX® 182 to plastic sheath pipe 160

CALPEX® 182 to plastic sheath pipe 180

CALPEX® 182 to plastic sheath pipe 200

CALPEX® 182 to plastic sheath pipe 225

CALPEX® 182 to plastic sheath pipe 250

Art.-Nr.

63196

63243

63308

63189

63199

63260

63311

63190

63219

63262

63312

63191

63234

63263

63313

63193

63235

63271

63314

63194

63195

63242

63293

63540

63541

63242

18109

18120

18121

18122

Connecting socket-set CPX-KMR for CALPEX®-Uno Heating/Sanitary, without insulating material, suitable for

CALPEX®-Connecting socket-set, type CALPEX®-plastic sheath pipe (KMR)for pipes 6 and 10 bar, without insulating material, comprising: one PEH-socket pipe(reduced at one side for reducing sockets), two PE-shrinking hoses and a grindingbelt.

Sockets for plastic sheath pipes32

High Bending Capacity

Page 32: CALPEX Brochure

Accessories Heating/Sanitary

Accessories

Connecting chamber

Art.-Nr.

69783

Connecting chambercomprising a chamber, cap, screws, subject disks, nuts and

assembly instruction

Dimensions in mm

for outer diameter CALPEX® 76

for outer diameter CALPEX® 91

for outer diameter CALPEX® 111

for outer diameter CALPEX® 126

for outer diameter CALPEX® 142

for outer diameter CALPEX® 162

for outer diameter CALPEX® 182

Art.-Nr.

69790

69789

69788

69787

69786

69785

18270

Entry sealingfor connecting chamber comprising shrinking hoses, grinding belt to the dimensions with

outer diameter 76, 91 and 126 with centering ring

Warning tape (Length customized)

Art.-Nr.

35702

Manual press tool DN 16–32 (5⁄8 –1 1⁄4")

Art.-Nr.

68729

Leasable tool kits for press connectingcomprising tool box (expansion tool & press tool)

Trench warning tape CPXwith imprint «Achtung Fernwärmeleitung»

Hydraulic expansion tool DN 40–100 (11⁄2 – 4")

Hydraulic press yoke DN 40–100 (11⁄2 – 4")

Art.-Nr.

63593

68740

33

Both tool boxes are necessary.

Page 33: CALPEX Brochure

Checklist34

Checklist

With CALPEX®-UNO

Quantity

2

4

4

4

4

4

4

1

Material

Single-line pipe

CPX-UNO

Sealing rings CPX

or

Sealing rings DOYMA

End caps CPX

for dry rooms or

shrinking end caps CPX

for wet rooms

Connection pieces CPX,

screw connection or

Connecting pieces CPX,

press connection

Trench warning tape

With CALPEX®-DUO

Quantity

1

2

2

2

2

4

4

1

Material

Twin-line pipe

CPX-DUO

Sealing rings CPX

or

Sealing rings DOYMA

End caps CPX

for dry rooms or

shrinking end caps CPX

for wet rooms

Connection pieces CPX,

screw connection or

Connection pieces CPX,

press connection

Trench warning tape

Example 1: House-House Connection

With CALPEX®-UNO

Quantity

6

6

6

6

6

6

6

2

2

1

1

Material

Single-line pipes

CPX-UNO

Sealing rings CPX

or

Sealing rings DOYMA

End caps CPX

for dry rooms or

shrinking end caps CPX

for wet rooms

Connection pieces CPX,

screw connection or

Connection pieces CPX,

press connection

T-pieces CPX-UNO,

press connection

Montage CPX T-piece

or

Connecting chamber

shrinking hoses

Trench warning tape

With CALPEX®-DUO

Quantity

3

3

3

3

3

6

6

2

1

1

1

Material

Twin-line pipes

CPX-DUO

Sealing rings CPX

or

Sealing rings DOYMA

End caps CPX

for dry rooms or

shrinking end caps CPX

for wet rooms

Connection pieces CPX,

screw connection or

Connection pieces CPX,

press connection

T-pieces CPX-UNO,

press connection

Montage CPX T-piece

or

Connecting chamber

shrinking hoses

Trench warning tape

Exemple 2: House-House-Connection with branch line

Page 34: CALPEX Brochure

Installation Tools/Transport/Storage 35

Installation Tools

Transport

Storage

Basic tool

Saw

Sharp knife

Plastic- or rubber mallet

Gas burner

Cleaning agent and cloth

2 adjustable spanners

Drill machine & pin drill

Gloves

Goggles

Working steps

Cutting the sheathed pipe and insulation

Removing the insulation

Auxiliary tool

For all shrinking tasks

Cleaning the casing

Tightening the cap nut/holding of the connections in case of PEX-screw

connections

When operating with sockets, drilling the hole where to fill in the foam

When operating with gas burner

Protection of the eyes while operating with PUR-foam cartridge

Max. delivery height 2800 mm

Max. delivery width 800/1200 mm

Max. Delivery length up to 760 m depending upon dimension

Delivery Weight 1–6.38 kg/m

Accessories cardboard-packs

When using a fork-lift to unload the rings, the forks should be protected in order to avoid cutting

into the pipe casing.

Before laying, pipes must be stored at min. 10°C.

Do not remove protective caps before laying.

Store dry cardboard with accessories.

The installation instruction is one of the most important tools!

Page 35: CALPEX Brochure

Trench dimensions/Laying/Aligning the pipe ends

Trench space dimensions

36

LayingDo NOT roll the CALPEX® ring out over edges, and do NOT pull the unrolled pipe over long distances on the asphalt. This can cause damage to

the protective polyethylene casing. Damaged points on the casing can be repaired, using the shrink socket.

Aligning the pipe endsIf necessary (e.g. if the laying temperature is low, or the pipe diameter is large) curved pipe ends can be bent straight with the help of an aligning rail.

Dimensions in mm

1 Trench warning tape

2 Excavated material

3 Sand washed, grain size 0– 3⁄4 mm

Covering hight: Max.covering hight: 2.6 m, the higher covering needs advise from Brugg Rohrsysteme. SLW

30 =̂ 300kN wheel load DIN 1072; for bigger loads (z.B. SLW 60) a load distribution superstructure accor-

ding RSt075 is required. Without traffic load the minimum covering hight may be reduced by 20 cm.

Trench sectionAny projecting stones and rocks in the trench must be removed.

1

Fix the CALPEX® pipe to one end ofthe rail, using the tensioning belt.

2

Fix the CALPEX® pipe to the other endof the rail.

3

Use hot air or hot water to heat themedium pipe; let it cool - and the jobis finished.

.

. ..

..

.

..

... .

.

.

.

.

..

..

.

...

. .

.. ..

..

..

.

.

..

.

. .. .

.

.

D10

.

.

10 1010 D D

*60

10

30

UNO 1 2 3

. ..

.

.

.

.

.. . .

.

.

.. .

.

.

.

.

.

...

.

..

D10

10 D

*60

10

30

10

. . ..

.

DUO, QUADRIGA 1 2 3

1

Place the CALPEX® ring at the start ofthe line, and cut the outermost fixingtape.

2

Unroll the ring as far as the next fixingtape; only now should you cut thenext fixing tape.

3

Repeat this procedure until the ringhas been unrolled.

Important! CALPEX® rings are under tension! Under no circumstances must you cut all the fixing tapes together. Uncontrolled release of the ten-

sion in the rings is DANGEROUS (spring effect).

Page 36: CALPEX Brochure

Connection CALPEX®-KMR

1 Transit from T-piece 2 Transition with fixed point

3 Transition with Z elbow 4 Transition with expansion elbow

Laying instruction for transition CALPEX® on plastic sheath pipe (KMR)

Laying Instructions 37

DS = Expansion leg ∆l = Expansion FP = Plastic sheath pipe-fixed point DK = Expansion pads All dimensions in m

The lateral expansion ∆l must only be sufficient for theexpansion to be absorbed by the T-branch DS and byCALPEX® district heating pipes.

min. 1.0 DS ≤ 2.0

≤ 2.0 KMR

KMR

GFK Shell

FP

FP

DK KMR

KMR

DKSocket

1.0 m DS ≤ 2.5

∆l

∆l

L

KMR

DKSocket

1.0 m DS ≤ 2.5

∆l L

∆l

∆l< 2.0 m

Pipe joint

Muffe

DK

Rmin

Rmin

The expansion ∆l, owing to increase of temperature,must not be compensated by the CALPEX® district heating pipes.Installation of a fixed point.

Laying of Z elbow according of the expansion ∆l.which must be compensated by section DS.

If pipe length L resp. ∆l is > than permitted, a fixedpoint should be included to allow exact check of theexpansions.

• Design of expansion elements • Location of expansion pads according to chapter plastic sheath pipe of the main catalogue.

Min. Bending radius (m)

at CALPEX®-Outer diameter 76 mm 0.7

at CALPEX®-Outer diameter 91 mm 0.8

at CALPEX®-Outer diameter 111 mm 0.9

at CALPEX®-Outer diameter 126 mm 1.0

at CALPEX®-Outer diameter 142 mm 1.1

at CALPEX®-Outer diameter 162 mm 1.2

at CALPEX®-Outer diameter 182 mm 1.4

Min. Bending radius

Page 37: CALPEX Brochure

Building Entry38

Building Entry

Core drilling

Prerequisites for installation are perfect drill holes. Since hairline cracks can exist in concrete or can arise as a result of the work,

we recommend sealing the hole over the entire length with a sealant (e.g. AQUAGARD).

Wall breakthrough

Core drilling

Wall entry DOYMA

L min

450

500

500

550

600

650

670

H

250

250

300

300

350

350

400

Protective sheath Ø D

78

93

113

128

143

163

183

D1 min

180

200

220

240

260

280

300

A

210

230

250

270

290

310

330

Protective sheath Ø D

78

93

113

128

143

163

183

D Pipe liner

Core drilling

Ø

150

150

200

200

250

250

300

DOYMA sealing set C40

DOYMA sealing set type A40

Ø D inside

78

93

113

128

143

163

183

Casing

PE Ø

76

91

111

126

142

162

182

Tightness can only be guaranteed if this recommendation is followed.

L

H

80 80100D D

A

Out

side

Base

men

t si

de

(Insi

de) 1 CALPEX® district heating pipe

2 DOYMA sealing set C40 double-sealing, width 2x40 mm, Shore hardness 35

3 DOYMA sealing set type A40 (centring), width 1 x 20 mm

4 Pipe liner made of fibre cement or coated core bore

D1

30

3 24

1

R D

All dimensions in mm

All dimensions in mm

All dimensions in mm

Ø D outside

150

150

200

200

250

250

300

Page 38: CALPEX Brochure

House-Connection 39

House-ConnectionConnection with male thread

Connection with weld-on end

Resulting fix point forces for CALPEX® pipe

ca. 80

ca. 80

*80

All dimensions in mm

* Dimensions may be reduced by max. 60 mm when end-cap is walled in.

* Dimensions may be reduced by max. 60 mm when end cap CPX is used for

dry rooms.

All dimensions in mm

Length A with

Press connection

260

260

270

270

320

320

330

340

260

260

260

270

270

270

Length A with

Screw connection

210

220

220

220

230

235

260

270

210

210

220

220

220

230

Heating, 6 bar

Dim. PEX-Pipe

25 x 2.3

32 x 2.9

40 x 3.7

50 x 4.6

63 x 5.8

75 x 6.8

90 x 8.2

110 x 10.0

Sanitary, 10 bar

22 x 3.0

28 x 4.0

32 x 4.4

40 x 5.5

50 x 6.9

63 x 8.7

Length B with

Press connection

250

250

260

270

310

310

310

310

Length B with

Screw connection

340

340

340

360

340

340

410

450

Heating, 6 bar

Dim. PEX-Pipe

25 x 2.3

32 x 2.9

40 x 2.9

50 x 4.6

63 x 5.8

75 x 6.8

90 x 8.2

110 x 10.0

CALPEX® Heating, 6 bar

Max. resulting fix point forces for each pipe at:

TB = 90 °C, pB = 6 bar

Type DN Fmax (N)

25/ 70 20 925

32/ 76 25 1495

40/111 32 2365

50/111 40 3685

63/126 50 5785

75/142 65 8205

90/162 80 11860

110/162 100 17675

TB = 60 °C, pB = 6 bar

Type DN Fmax (N)

25/ 76 20 755

32/ 76 25 1225

40/111 32 1940

50/111 40 3015

63/126 50 4740

75/142 65 6720

90/162 80 9720

110/162 100 14480

Fixed point

Fixed point Shrinkable end cap for wet rooms

Wall sealing ringCALPEX®-Heating pipe

PEX-connection piecewith male thread Press-

or screwconnection

Shrinkableend cap forwet rooms

PEX-connection piecewith weld end Press- or screw

connection

CALPEX® Sanitary, 10 bar

Max. resulting fix point forces for each pipe at:

TB = 60 °C, pB = 10 bar

Type DN Fmax (N)

22/ 76 16 820

28/ 76 20 1350

32/ 76 25 1730

40/ 91 32 2700

50/111 40 4230

63/126 50 6715

*80

max

.100

*A

*B

with press- or screw connection

Page 39: CALPEX Brochure

Installation Instruction CALPEX®40

REHAU-Press connection

UNO DUO QUADRIGADN 16– 40: X = 140 mmDN 50–100:X = 180 mm

DN 16– 40: Y, Z = 140 mm

Y = Z =140 mm

Installation Instructions CALPEX®

Beulco-Screw connection

Stripping, pipe-preparation

1

Mark the distance x, (y) +1 cm fromthe end of the pipe.

2

Cut the jacket with a pipe-cutter or asaw at the distance X,(Z) from theend of the pipe.

3

Open the jacket longitudinally.Knife max. 5 mm deep into foam.

4

Remove jacket5

Cut back insulation over the distancex, (y). Attention: Service-pipe withbarrier of EVOH! Be careful!

7

Grinde protective sheath.

6

Mount the wall seal. Stretch the clip(if existing)

9

Cut the PEX-Pipe square to its axis(max.1 cm).

8

Carefully put end cap CPX for belowground onto the pipe according tothe enclosed Raychem DHEC installa-tion instruction or attach end capCPX for above ground.

DN 16–65: X = 90 mmDN 80, 100:X = 140 mm

UNO DUO QUADRIGADN 16– 40: Y = 80 mmDN 16–40:Z = 180 mm

Y = Heating =110 mmZ = Sanitary =200 mm

Page 40: CALPEX Brochure

Installation Instruction CALPEX®

REHAU-press-type joint

Beulco screw joint

1

Put the union nut and theclamping ring onto thepipe.

2

Heat PEX-pipe up to 60 C.3

Push the muff as far asthe base of the recess.

4

Move the union nut, theclamping ring and the mufftogether, and tighten themadequately.Caution: do not overtighten!

5

Heat the Beulco fitting to60–80 °C again.

6

Re-tighten the fitting.Caution: do not overtighten!

7

The job is finished!

1

Push the sliding sleeveover the pipe; the innerridge must point to theend of the pipe (with theconical end of the slidingsleeve towards the end ofthe pipe).

2

Widen the pipe twice,with a 30° offset; the sli-ding sleeve must not belocated in the widenedzone.

3

Insert the fitting in thepipe, and the fitting will“sit” firmly in the pipeafter a short while(memory effect).

4

Apply the tool; do not tilt.

5

Move the selector buttonto the slide position.

6

With levering movements,push the slider sleeve asfar as the collar of the fit-ting.

7

Move the selector buttonto the reset position.

8

Press the levers togetheragain, then swivel themovable lever upwards by90° to move the tool intoits initial position.

9

The job is finished!

41

Page 41: CALPEX Brochure

Fitting instructions - chamber

Fitting instructions for T-piece

1

Connect the pipes to theT-piece as described in thefitting instructions for theREHAU press-type joint.

2

If necessary, cut thereduction to size with ametal cutting saw.

3

Place the sealing tape inthe joints (by the ends onboth shells) and applygentle pressure.

4

If necessary, place thereduction ring around thepipe and wrap sealingtape around it (wind around twice). Place theT-piece with the pipesinto the open shell.

pushed up by the foam(the nylon thread showsthis), fit the sealing capwith the seal.

4

Grind the shaft mouths.

5

Using a torque wrench,evenly screw the shellstogether clockwise (maxi-mum torque: 10.5 Nm).Wait for 10 minutes; thentighten the screws.

6

Perform an air pressuretest (maximum: 0.3 bar)and then foam the shells,holding the foam packingover (not in) the hole.Wear safety googles!

7

Fit the sealing screwimmediately, making surethat the sealing ring fitsproperly. As soon as theball in the sealing screw is

1

Saw the shaft mouth tomatch the outer diameterof the pipe - Ø 136, 166or 186 mm are possible.

2

Pull the shrink hose overthe pipe ends.

3

Fit the two-section redu-cer ring (only needed forCPX dimensions 76, 91and 126 mm).

5

Remove the protective filmfrom the shrink hose andheat-shrink. Filling/insulati-on material:- polystyrene fragments- Armaflex or Tubolit

6

Screw the shaft togetherwith the cover, includingthe sealing ring (screws,washers and nuts are sup-plied).

7

A pressure distributionplate must be used whe-rever there could bepublic traffic.

The maximum surfaceload must not exceedq = 153 kN/m2

(SLW 60 to DIN 1055).

CALPEX® Fitting Instructions42

Page 42: CALPEX Brochure

Request per Fax 43

Have you got projects where you can use CALPEX® ? Then copy this page, fill it in and fax it to us. There are many other pipe solutions available on request.

Request per Fax

Medium:(pipe contents) Temperature:

Pressure: Flow quantity: ∆ T

Product specification: Laying:

❏ pre-insulated ❏ in the earth

❏ with leak detection ❏ in the house

❏ with heating cable ❏ in the installation channel

❏ with explosion protection ❏ under the bridge

❏ double-walled ❏ in the tunnel

Remarks/Sketch:

Brugg Rohrsystem AGFernwärme- und Flüssigkeitstransport-Leitungen

CH-5314 KleindöttingenIndustriestrasse 39Postfach 99Telefon +41 (0)56-268 78 78

Fax +41 (0)56-268 78 79

Telefax from: To:

Page 43: CALPEX Brochure

The pipe systemprofessionals

Profitability and save

operation with efficient

pipe systems

Your partner for pipe systems

We are the people you should talk to when you need

to find efficient solutions for transporting liquid mate-

rials. With our project engineers, our Development

Department, our in-house production unit and our pro-

fessional team of fitters, we have the know-how and

the resources to look after your projects competently

and reliably. For all types of heating systems, petrol sta-

tion construction, industrial plant construction and

domestic engineering.

Online documentation

You can call up detailed product documentation in pdf

format at www.pipesystems.com or www.brugg.de.

Customer-specific solutions

Brugg Pipe Systems offer a full range of single-walled,

double-walled and heat-insulated pipe systems. Thanks

to our know-how in this sector, we can manufacture

special project-based products. Please call us – our

engineers will be glad to advise you and to devise a

tailor-made solution.

BRUGG Rohrsysteme GmbH

Adolf-Oesterheld-Strasse 31

D-31515 Wunstorf

Telefon +49 (0)50 31 170-0

Telefax +49 (0)50 31 170-170

www.brugg.de

[email protected]

Brugg Rohrsystem AG

Industriestrasse 39

CH-5314 Kleindöttingen

Telefon +41 (0)56 268 78 78

Telefax +41 (0)56 268 78 79

www.pipesystems.com

[email protected]

Ein Unternehmen der Gruppe BRUGG

www.pipesystems.com

www.brugg.de

ISO 9001ISO 14001

flexible solutionsflexible solutions