call us first! do not return to storeheartlandind.com/wp-content/uploads/2015/08/... · stratford...
TRANSCRIPT
![Page 1: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/1.jpg)
STOP!STOP!
Call Us First!DO NOT RETURN TO STORE.
For immediate help with assembly or product information
call our toll-free number:
or email:
Our staff is ready to provide assistance.
April through October M - F 8:00 AM to 7:00 PM EST
Saturday 8:30 AM to 4:30 PM EST
November through March M - F 8:00 AM to 5:00 PM EST
1-800-577-9663
16665
![Page 2: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/2.jpg)
(This page intentionally left blank.)
![Page 3: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/3.jpg)
A Backyard Products Company
10/30/2012
KEEP THIS MANUAL FOR FUTURE REFERENCE
ACTUAL FLOOR SIZE IS 141 x 96" (358 x 244 cm) STRATFORD 12' x 8' (366 x 244 cm)
ASSEMBLY MANUAL
BEFORE YOU BEGIN
VALUE SERIES
16665
IMPORTANT!READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY.
- CUSTOMER SERVICE -Call: 1-800-577-9663 email: [email protected]
• BUILDING RESTRICTIONS AND APPROVALS Be sure to check local building department and homeowners association for specific restrictions and/ or requirements before building
. • ENGINEERED DRAWINGSContact our Customer Service Team if engineered drawings are needed to pull local permits.
• SURFACE PREPARATION To ensure proper assembly you must build your shed on a level surface. Recommended methods and materials to level your shed are
listed on page 4.
• CHECK ALL PARTSInventory all parts listed on pages 4 - 6. Contact our Customer Service Team if any parts are missing or damaged.
• ADDITIONAL MATERIALSYou will need additional materials to complete your shed. See page 3 for required and optional materials and quantities. .
![Page 4: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/4.jpg)
2
FINISH
BEGIN
1̧
� 3/8" Drill Bit
� Square
� Utility Knife
TOOLS
Safety! Always use approved safety glasses during assembly.
OptionalRequired
HELPFUL REMINDER SYMBOLSLook for these symbols for helpful reminders throughout this manual.
ORIENT LUMBER AND TRIM FOR BEST APPEARANCE
= Assistance Required; two or more people.
= Ensure squareness.
= Important required step or operation.
= Helpful assembly hint.
= Mark part with pencil.
= Beginning of steps for assembly or installation.
= You have fi nished the assembly or installation.
= Level
� Gloves
Framing lumber is graded for structural strength and not appearance. Exterior trim is graded for one good side.
Always install the material leaving the best edge and best surface visible. Please remember that these blemishes in no waynegatively affect the strength or integrity of our product. (See Fig. A, B, C.)
� Safety Glasses
� Tape Measure
� Paint Tools
� Ladder
� Caulk Gun
�Hammer
� Level
� Pencil
� Phillips Screwdriver
� Drill / Driver
� #2 Philips Drive Bit
� Tool Belt/ Nail Pouch
� Chalk Line
� Nail Gun
• gun nails
� Tin Snips (for drip edge)
or
� Shingle Blades
A B C
![Page 5: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/5.jpg)
3
FOUNDATION OR FLOOR MATERIALS
ADDITIONAL MATERIALS
DRIP EDGE ..................... 30 Feet #15 ROOFING FELT To cover 114 Sq. Ft. of roof area.
1" GALVANIZED ROOFING NAILS.........1/4 LbFor roofing felt.
x6
x20
2 x 4 x 8' (5 x 10 x 244 cm) Treated Lumber Cut to (5) 2 x 4 x 93" (5 x 10 x 236,2 cm) ea. 3" (7,6 cm) Hot Dipped Galvanized Nails
Optional 12" (30 cm) spacing
Standard 24" (60 cm) spacing
• This shed kit includes a complete wood fl oor frame system. It does not include floor panels.• It does not include ANY leveling materials.
• See the FLOOR LEVELING section on page 8 for recommended methods and suggested materials to properly level your fl oor, as this will vary depending on your specifi c site.
REINFORCED WOOD FLOOR FRAME (OPTIONAL)IMPORTANT! The included fl
fi c use you may want to construct a fl oor frame by adding additional fl
COMPLETING YOUR SHEDYou will need these additional materials:
OPTIONAL MATERIALS
3-TAB SHINGLES ............................ 5 Bundle s
PAINT FOR SIDING .......................... 2 GallonsUse 100% acrylic latex exterior paint. (2) coats r ecommended.
CAULK ................................................. 3 Tube sUse acrylic latex exterior caulk that is paintable.
s1" GALVANIZED ROOFING NAILS.... 2 LbFor shingles.
PAINT FOR TRIM .............................1 QuartUse 100% acrylic latex exterior paint.
WOOD GLUE ....................... Exterior Rated
FLOOR PANELS (NOT INCLUDED)
REFER TO THE BACK OF THIS MANUAL AND THE MANUFACTURER’S INSTRUCTIONS FOR INSTALLATION OF SHINGLES, DRIP EDGE AND FELT.
x2 x13/4 x 48 x 96"(1,9 x 122 x 244 cm)
3/4 x 45 x 96"(1,9 x 114 x 244 cm)
Floor Panels are3/4" (1,9 cm) thick
![Page 6: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/6.jpg)
4
RS RS
3/4"(19 mm)
1" x 4".................3/4" x 3-1/2" (1,9 x 8,9 cm )
2" x 4"..............1-1/2" x 3-1/2" (3,8 x 8,9 cm )
2" x 3"..............1-1/2" x 2-1/2" (3,8 x 6,3 cm )
1" x 3".................3/4" x 2-1/2" (3,8 x 6,3 cm )
x9x2
2 x 4 x 93" (5 x 10 x 236 cm)
2 x 4 x 48" (5 x 10 x 122 cm)
2 x 3 x 24-1/16" (5 x 7,6 x 61 cm)
2 x 3 x 7-7/8" (5 x 7,6 x 20 cm) 1 x 3 x 5" (2,5 x 7,6 x 12,7 cm)Gauge Block for 3/4" (19 mm)measurement
2 x 3 x 14-1/2" (5 x 7,6 x 36,8 cm)
2 x 3 x 66-1/2" (5 x 7,6 x 169 cm)
2 x 3 x 29-1/2" (5 x 10 x 75 cm)
2 x 3 x 32-1/2" (5 x 10 x 83 cm)
2 x 3 x 46-1/2" (5 x 7,6 x 118 cm)
2 x 3 x 94-1/2" (5 x 7,6 x 240 cm)
2 x 3 x 96" (5 x 7,6 x 244 cm)
2 x 3 x 13" (5 x 7,6 x 33 cm)
2 x 3 x 68" (5 x 7,6 x 173 cm)
FL
x2 x1x1
x1
x5x1 2 x 3 x 62-1/2" (5 x 7,6 x 158,8 cm)
x3
x3
x3x6x7
x5
x1
FN
GAADY
FZ
KK
KZ
2 x 3 x 22-1/2" (5 x 7,6 x 57 cm) x2 LV
2 x 3 x 21-1/2" (5 x 7,6 x 55)x2 LF
NF
PR
PT
RK
OT
2 x 4 x 65-5/8" (5 x 10 x 167 cm) Rafter
2 x 4 x 46-13/16" (5 x 10 x 119 cm) Rafter
ADNU
x5x5
8 x 24" (20 x 61 cm) Gusset
5/8 x 3 x 25" (1,6 x 7,6 x 63,5 cm)
5/8 x 3 x 8" (1,6 x 7,6 x 20 cm)
5/8 x 3 x 72-3/8" (1,6 x 7,6 x 184 cm)
2 x 3 x 70-1/2" (5 x 7,6 x 179 cm)
2 x 3 x 65" (5 x 7,6 x 165 cm)
x6x4x2
x2
x2
x2
KW
KV
ZZ
KX
KY
MM
NO
NR
NQ
3/8 x 5-3/8 x 5-1/2" (1 x 13,6 x 14 cm) 1 Left / 1 Rightx2
x2x2
2 x 3 x 46-7/8" (5 x 7 x 119 cm)
5/8 x 3 x 14" (1,6 x 7,6 x 35,5 cm)
2 x 3 x 76-1/4" (5 x 7,6 x 194 cm)
x8
WOODSIZECONVERSIONCHARTNominalBoardSize ActualSize
PARTS IDENTIFICATION AND SIZESF
LOO
RR
AF
TE
RS
TR
IMW
ALL
S
Part identification is stamped on some parts.
• Check these locations for Part stamps
Treated lumber is stamped:
Treated lumber is stamped:
PARTS LISTINVENTORY YOUR PARTS before you begin. We suggest sorting parts by the category they are listed in.
BJ
5/8 x 3 x 21-3/4" (1,6 x 7,6 x 55 cm)
x10
![Page 7: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/7.jpg)
5
x1x2 x2
x3 x1x2 x1 x1 x1 x1
7/16 x 18 x 96”(1,1 x 46 x 244 cm)
x17/16 x 18 x 48”(1,1 x 46 x 122 cm)
7/16 x 48 x 96"(1,1 x 122 x 244 cm)
7/16 x 47-7/8 x 48"(1,1 x 122 x 122 cm)
x1 x1 3/8 x 7-7/8 x 94-1/2" (0,9 x 20 x 240 cm)
3/8 x 48 x 72" (1 x 122 x 183 cm)
3/8 x 15-7/8 x 72" (1 x 40 x 183 cm)
3/8 x 7-7/8 x 46-1/2" (0,9 x 20 x 118 cm)
Roof Panels are7/16" (11 mm) thick
WALL PANEL & DOOR PARTS LIST
ROOF PANELS
Left Door Right Doorx1 x1
2 x 3 x 69" (5 x 7,6 x 175,3 cm)x2OO
5/8 x 3-7/8 x 96" (1,6 x 9,8 x 244 cm)x1
NOTES
![Page 8: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/8.jpg)
6
5/8 x 20 x 96"(1,6 x 51 x 244 cm)
7/16 x 11-3/4 x 96"(1,1 x 30 x 244 cm)
1 x 3 x 96"(2,5 x 7,6 x 244 cm)
Window
23-7/8 x 96"(61 x 244 cm) Peg Board
x1 x2
x1
x1
x1
x30
x74
x36
x2Boxes
x6Boxes
x112
x112
x25
x75
3" (7,6 cm)
3" (7,6 cm)
2" (5,0 cm)
2" (5,0 cm)
2" (5,0 cm)
1-1/4" (3,2 cm)
1-1/2" (3,8 cm)
1" (2,5 cm)
3/4" (19 mm)
SHELF & WINDOW PARTS LIST
FASTENERS / HARDWARE BAG (Shown actual size)
NAIL BOXES (Shown actual size)
DOOR HARDWARE (Not actual size)
BE
3/4" (19 mm) 3/4" (19 mm) 3/4" (19 mm)
64" Metal Threshold
Bagged seperately / special coating
x2
x8
x1 x1
x7 x11
![Page 9: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/9.jpg)
7
BUILDING ANATOMY
1. Sub-assembled doors with attached hinges.
2. 2x3 wall studs have been engineered to support roof load and to meet demanding wind loads.
3. Sidewall top and bottom plates tie wall studs together and provide nailing support for top and bottom edge of siding.
4. Rafters line up over wall studs to effectively transfer roof load to the floor and eliminate need for double top plate. Oversized wood gussets at peak provide a strong connection for rafter halves.
5. Treated siding overhangs the wall framing and floor to keep the elements out.
6. Collar tie and over-door header maintains door frame integrity. 7. Corner studs & end rafters are positioned to the outside of the siding where they serve the dual purpose of framing and trim.
8. The EZ Frame design transfers the roof load to the front and back walls allowing for reduced framing at the side walls.
9. Includes treated floor frame.
This building has been designed using our patented EZ Frame construction method. EZ Frame is a unique construction method which has been engineered to use fewer framing members. This reduces assembly time and cost by as much as 30% compared to conventional construction methods. EZ Frame patent no. 5,666,766
All of our buildings have been engineered to withstand demanding wind and snow loads. If you live in an area with extreme wind/snow load requirement, contact
us and we can assist with engineering to meet your local codes.
1
2
3
4
5
6
7
8
9
9
7
3
2
6
85
4
1
![Page 10: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/10.jpg)
8
FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below.
Leveling materials are not included in this kit.
PREFERRED METHOD - 4x4 TREATED RUNNERS
Measurementstocentersof4x4's.
• 3" Screws angled into 4x4.
• (2) at each point frame• and 4x4 touch.
12"(30,5 cm)
12"(30,5 cm)
• Level under 4x4 runners only.• Locate leveling material 12" from ends of runners and no more than 48" apart.• Asphalt shingles should be used between 4x4 runners and blocks or treated lumber. Never use shingles in direct contact with ground.• For best results and aiding in water drainage use gravel under each concrete block.
LEVELINGMETHODS
• If you are building your shed on a concrete foundation see the following page.
CONCRETE
MATERIALREQUIRED
x2 4" x 4" x 12' (10 x 10 x 366 cm)Treated Lumber
FastenersforFrameto4"x4".(3" Screws shown as one option.) Minimum (28) 3" screws / exterior grade.
Useonlywoodtreatedforgroundcontactandfastenersapprovedforusewithtreatedwood.
Alwayssupportframeseams.
Levelinghigherthan16"notrecommended.
LEVELINGMATERIALSGravel
2x4 Treated Lumber
Solid Masonry Blocks in 1", 2", 4" or 8" thickness
Asphalt Shingles
8" Block
4" BlockGravelGravel
Do not exceed 16".
4x4 Runner
Shingle
ShingleMaximum between leveling
material locations.48"
12"
2x4 Treated Lumber
2" Block
Level
12"
![Page 11: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/11.jpg)
9
A
B C
4"(10 cm)
3-1/2"(8,9 cm)
DOOR
2" x 4" x 12' (5 x 10 x 366 cm)
2" x 4" x 8' (5 x 10 x 244 cm)
Caulk
Requires:
x2
x2
x1
MUST be treated lumber.
MUST be treated lumber.
96" (244 cm)141" x 96" (358 x 244 cm) 89" (226 cm)12'x 8' (366 x 244 cm) 141" (358 cm)
AActual Size B CBuilding Size
CONCRETE FOUNDATION Your kit contains all materials to construct a wooden floor frame. If you choose to install your kit
on a concrete slab refer to the diagram below.
• A treated 2 x 4" (5 x 10 cm) sill plate is required when installing your shed on concrete. Hint: Use treated lumber in your kit or purchase full length treated lumber. • Use a high quality exterior grade caulk beneath all sill plates. • Fasten 2 x 4" (5 x 10 cm) sill plates to slab using approved concrete anchors (fasteners not included). • Check local code for concrete foundation requirements.
NOTES
Treated Sill Plate
Caulk between sill plate and concrete.
Allow new concrete slabs to cure for at least seven (7) days.
![Page 12: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/12.jpg)
10
93"(236 cm)
96"(244 cm)
141”(358 cm)
117”(297 cm)
93”(236 cm)
93”(236 cm)
70-1/2”(179 cm)
48”(122 cm)
24”(61 cm
48”(122 cm)
93”(236 cm)
OffsetSeam
OffsetSeam
x323" (7,6 cm)
x9
x2
2 x 4 x 93" (5 x 10 x 236 cm)
2 x 4 x 48" (5 x 10 x 122 cm)
PARTSREQUIRED:
FINISH
3 You have fi nished your Floor Frame.
Use two 3" nails at each mark.
Orient parts as shown on fl at surface. Measure and mark.
Somemeasurementsnottypical24"spacing
Centeronmarks
FLOOR FRAME
Flush
Flush
Look for StampTREATED
2
BEGIN
1̧
HINT:Foreasiernailingstandonframe.
![Page 13: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/13.jpg)
11
First,secureatendswithonefastener.
Second,secureatendswithonefastener.
170-9/16"(433,3 cm)
170-9/16"(433,3 cm)
Fig.A
FINISH
5
LEVEL AND SQUARE FLOOR FRAMEBefore attaching fl oor decking, it is important to level and square the fl oor frame.
A level and square fl oor frame is required to correctly construct your shed.
BEGIN
1̧
2
3
4
1
Use level and check the frame is level before applying fl oor panels.
Check for frame squareness by measuring diagonally across corners. If the measurements are the same, the frame is square. The diagonal measurement will be approximately 170-9/16" (433,3 cm).
When the frame is level and square secure one side of frame to the 4x4 runners using one fastener at ends of each runner. Move to the opposite end of the frame. Secure the frame to 4x4 runners with one fastener at ends of each runner making sure the frame remains square (Fig.A).
Once the fl oor frame is level and square fasten the frame to the x4 runners at each point the frame contacts the 4x4 runners.
See page 8 for the preferred fl oor leveling method.
![Page 14: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/14.jpg)
12
48"(122 cm)
141"(358 cm)
6"(15 cm)
PARTS REQUIRED:
x1
x55
3/4 x 48 x 96"(1,9 x 122 x 244 cm)
Grid lines up
12" (30 cm)
2" (5 cm)
Flush
Flush
Flush
(2) Nails
(2) Nails
FLOOR PANELS (NOT INCLUDED)
3/4" (1,9 cm)
170-9/16" (433,3 cm)
170-9/16" (433,3 cm)
Attach the 3/4 x 48 x 96" panel with the rough side up (painted-grid lines side) with the 48" edge and corner flush to the floor frame (Fig A). Secure panel with two 2" nails in the corners.
Move to the opposite side. Using the long edge of the panel as a lever, move thepanel side-to-side until the top corner is flush to the floor frame (Fig. B).Secure panel with two 2" nails in the corners.
2
BEGIN¸11
3
4 Continue attaching the panel using 2" nails 6" apart on edges and 12" apart inside panel. Use a chalk line or use pre-painted grid lines to nail into joists under panel.
Ensure your floor frame is square by installing one paneland squaring frame.
Fig. A
Fig. B
Fig. C
Check the floor frame is square by measuring diagonally across the frame corners. If the measurements are the same your floor frame is square. The measurement will be approximately 170-9/16" (433,3 cm) (Fig. C).
Floor Panels not includedSee page 3 for panel sizes
and quantities.
![Page 15: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/15.jpg)
13
45"(114 cm)
48"(122 cm)
141"(358 cm)
6"(15 cm)
12"(30) cm
PARTS REQUIRED:
x1 3/4 x 45 x 96"(1,9 x 114 x 244 cm)
FINISH7 You have fi nished attaching your fl oor panels.
Continue installing panels with rough side up (painted grid lines).
Use grid lines on panel for 2" nails 6" apart on edges, and 12" apart inside panels.
5
76
x1 3/4 x 48 x 96"(1,9 x 122 x 244 cm)
Grid lines up
x1102" (5 cm)
FLOOR PANELS (NOT INCLUDED)
Flush
FlushFlush
45" Panel
![Page 16: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/16.jpg)
14
DOOR
Backwall
FrontwallSidewall
SideWall
Checkthefloorframeislevelafterinstallingfloorpanels.Re-levelifneeded.
•Thefloorshouldbeusedasalevelworksurfaceforwallconstruction.
• Organizeyourwallsectionsduringsub-assembly toavoidover-handlingofthewalls.HINT:
IMPORTANT!
![Page 17: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/17.jpg)
15
PARTSREQUIRED:
x12 x 3 x 76-1/4" (5 x 7,6 x 194 cm)
x1
MM
Flush
Primedsidedown
Fig.B
Fig.A
6"(15 cm)
2-1/2"(6,4 cm)
76-1/4"(194 cm)
76-1/4"(194 cm)
Checkforcorrectpanelshape.
2
3
Edges of panel should be flush to MM.
Use 1-1/4" (3,2 cm) screws spaced 6" (15 cm) apart as shown.
BEGIN
1̧ Orient parts on the flat on floor as shown(Fig.A,B).
Panel should be primed side down(Fig.B).
x131-1/4" (3,2 cm)
LEFT WALL
MM
![Page 18: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/18.jpg)
16
LEFT WALL
x1
Checkforcorrectpanelshape.
x121-1/4" (3,2 cm)
PARTSREQUIRED:
x1
5
4
6
Edges of panel should be fl ush to NO.
Use 1-1/4" (3,2 cm) screws spaced 6" (15 cm) apart as shown.
Orient parts on the fl at on fl oor as shown(Fig.A,B).
Panel should be primed side down(Fig.B).
Flush
6"(15 cm)
NO70-1/2"
(179 cm)
2 x 3 x 70-1/2" (5 x 7,6 x 179 cm)NO
FINISH
7 You have fi nished building your two Left Wall Assemblies.
Primedsidedown Fig.B
2-1/2"(6,4 cm)
Fig.A
70-1/2"(179 cm)
![Page 19: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/19.jpg)
17
1"(2,5 cm)
2-1/2"(5,4 cm)
33-1/2"(85 cm)
1-1/4"(3,2 cm)
33-1/2"(85 cm)
2-1/2" (6,4 cm)
Flush
Flush12"
(30 cm)
6"(15 cm)
KZ
PT
PTtemporarysupport
RKtemporarysupport
x121-1/2" (3,8 cm)
PARTSREQUIRED:
3
2
4
Nail KZ first, 1" (2,5 cm) from panel bottom.
Use 1-1/2" (3,8 cm) nails only 6" (15 cm) apart.
Place PT flush to KZ and edge of panel. Hold the 33-1/2" (85 cm) measurement and nail with 1-1/2" (3,8 cm) 12" (30 cm) apart.
Orient KZ and PT on flat on floor as shown.
Place panel on KZ and PTwith primed side up.
Primedsideup
Useonly1-1/2"(3,8cm)longnails
x1
x1x2
LEFTWALLREARASSEMBLY
2 x 3 x 32-1/2" (5 x 10 x 83 cm)
2 x 3 x 96" (5 x 7,6 x 244 cm)
KZ
PT
2 x 3 x 13" (5 x 7,6 x 33 cm) x1 RK
BEGIN
1̧
LEFT WALL
Donotnailingroove.
![Page 20: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/20.jpg)
18
58-1/4"(148 cm)
S
5/8"(16 mm)
2-1/2"(6,4 cm) Use
as spacer
Use Gauge Bloc kas spacer 3/4"
(19 mm)
Flush
58-1/4"(148 cm)
21-1/2"(54,6 cm)
29-1/2"(75 cm)
Flush
1-1/4"(3,2 cm)
2-1/2"(6,4 cm)
1-1/4"(3,2 cm)
12"(30 cm)
6"(15 cm)
BJ
Flush
LF
PT
RKtemporarysupport
x171-1/2" (3,8 cm)
PARTSREQUIRED:
7
5
6
8
9
Use 1-1/2" (3,8 cm) nails only 6" (15 cm) apart.
Place PT flush toLF and panel edge. Hold the 58-1/4" (148 cm) measurement and nail with 1-1/2" (3,8 cm) nails 12" (30 cm) apart.
Place the 5/8" (16mm) spacer on PT.
Place BJ flush to spacer and nail.
Place 3/4" gauge block on PT.
Place LF flush on gauge block and nail.
Useonly1-1/2"(3,8cm)longnails
x12 x 3 x 96" (5 x 7,6 x 244 cm)
PT
2 x 3 x 29-1/2" (5 x 10 x 75 cm) BJx1
2 x 3 x 21-1/2" (5 x 7,6 x 55)x1 LF
5/8 x 3 x 14" (1,6 x 7,6 x 35,5 cm)3/4"GAUGE
BLOCKTEMPORARYSPACERx1
LEFT WALL
Donotnailingroove.
![Page 21: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/21.jpg)
19
1"(2,5 cm)
33-1/2"(85 cm)
58-1/4"(148 cm)
1"(2,5 cm)
1-1/2"(3,8 cm)
1-1/2"(3,8 cm) Flush
Flush
2-3/4"(7 cm)
2-3/4"(7 cm)
1"(2,5 cm)
2-1/2"(6,4 cm)
x331-1/2" (3,8 cm)
PARTSREQUIRED:
11
12
10
Nail using 1-1/2" (3,8 cm) nails 6" (15 cm) apart on edges, and 12" apart inside panel.
Nail RK using three 1-1/2" (3,8 cm) nails (Fig.A).
Place panel onto frame primed side up.
You have fi nished your left wall. Proceed to build your right wall.
FINISH
13
LEFTWALLFRONTASSEMBLY
x1
Primedsideup
RK
Fig.A RK
2 x 3 x 13" (5 x 7,6 x 33 cm) x2 RK
LEFT WALL
Donotnailingroove.
Useonly1-1/2"(3,8cm)longnails
![Page 22: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/22.jpg)
20
Checkforcorrectpanelshape.
PARTSREQUIRED:
x12 x 3 x 76-1/4" (5 x 7,6 x 194 cm)
x1
2
3
Edges of panel should be flush to MM.
Use 1-1/4" (3,2 cm) screws spaced 6" (15 cm) apart as shown.
BEGIN
1̧ Orient parts on the flat on floor as shown(Fig.A,B).
Panel should be primed side down(Fig.B).
x131-1/4" (3,2 cm)
Flush
6"(15 cm)
MM76-1/4"
(194 cm)
Primedsidedown
Fig.B
RIGHT WALL
2-1/2"(6,4 cm)
Fig.A
76-1/4"(194 cm)
MM
![Page 23: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/23.jpg)
21
Primedsidedown
Fig.B
x1
x121-1/4" (3,2 cm)
PARTSREQUIRED:
x1
5
4
6
Edges of panel should be fl ush to NO.
Use 1-1/4" (3,2 cm) screws spaced 6" (15 cm) apart as shown.
Orient parts on the fl at on fl oor as shown (Fig.A,B).
Panel should be primed side down(Fig.B).
2 x 3 x 70-1/2" (5 x 7,6 x 179 cm)NO
FINISH
7 You have fi nished building your two right wall assemblies.
Checkforcorrectpanelshape.
Flush
6"(15 cm)
NO70-1/2"
(179 cm)
RIGHT WALL
2-1/2"(6,4 cm)
Fig.A
70-1/2"(179 cm)
![Page 24: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/24.jpg)
22
1"(2,5 cm)
33-1/2"(85 cm)
1-1/4"(3,2 cm)
2-1/2"(6,4 cm)
33-1/2"(85 cm)
2-1/2" (6,4 cm)
Flush
Flush12"
(30 cm)
6"(15 cm)
KZ
PT
PTtemporarysupport
RKtemporarysupport
x121-1/2" (3,8 cm)
PARTSREQUIRED:
3
2
4
Nail KZ first, 1" (2,5 cm) from panel bottom.
Use 1-1/2" (3,8 cm) nails 6" (15 cm) apart.
Place PT flush to KZ and edge of panel. Hold the 33-1/2" (85 cm) measurement and nail with 1-1/2" (3,8 cm) 12" (30 cm) apart.
Orient KZ and PT on the flat on floor as shown.
Place panel on KZ and PT with primed side up.
Primedsideup
x1
x1x2
RIGHTWALLREARASSEMBLY
2 x 3 x 32-1/2" (5 x 10 x 83 cm)
2 x 3 x 96" (5 x 7,6 x 244 cm)
KZ
PT
2 x 3 x 13" (5 x 7,6 x 33 cm) x1 RK
BEGIN
1̧
Useonly1-1/2"(3,8cm)longnails
RIGHT WALL
Donotnailingroove.
![Page 25: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/25.jpg)
23
33-1/2"(85 cm)
S
5/8"(16 mm) Use
as spacer
Flush
32-1/2"(82,5 cm)
Flush
1-1/4"(3,2 cm)
2-1/2"(6,4 cm)
21-1/2"(54,6 cm)
1-1/4"(3,2 cm)
2-1/2"(6,4 cm)
6"(15 cm)
LF
KZ
PT
RKtemporarysupport
x101-1/2" (3,8 cm)
PARTSREQUIRED:
7
5
6 Place the 5/8" (16 mm) spacer on KZ
Place LF flush to spacer and nail with 1-1/2" (3,8 cm) nails 6" (15 cm) apart.
Place KZ flush on PT and nail with 1-1/2" (3,8 cm) nails 6" (15 cm) apart.
x1
2 x 3 x 21-1/2" (5 x 7,6 x 55)x1 LF
5/8 x 3 x 14" (1,6 x 7,6 x 35,5 cm)x1
2 x 3 x 32-1/2" (5 x 10 x 83 cm)KZ
RIGHT WALL
Useonly1-1/2"(3,8cm)longnails
Donotnailingroove.
TEMPORARYSPACER
![Page 26: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/26.jpg)
24
1"(2,5 cm)
33-1/2"(85 cm)
1"(2,5 cm)
1-1/2"(3,8 cm)
1-1/2"(3,8 cm) Flush
Flush
2-3/4"(7 cm)
2-3/4"(7 cm)
12"(30 cm)
6"(15 cm)
x281-1/2" (3,8 cm)
PARTSREQUIRED:
RIGHTWALLFRONTASSEMBLY
x1
Primedsideup
RK Fig.A
2 x 3 x 13" (5 x 7,6 x 33 cm) x2 RK
RIGHT WALL
9
1010
8
Nail using 1-1/2" (3,8 cm) nails 6" (15 cm) apart on edges, and 12" apart inside panel.
Nail RK using three 1-1/2" (3,8 cm) nails (Fig.A).
Place panel onto frame primed side up.
You have fi nished your right wall.FINISH
11
Donotnailingroove.
Useonly1-1/2"(3,8cm)longnails
RK
1"(2,5 cm)
2-1/2"(6,4 cm)
![Page 27: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/27.jpg)
25
141"(358 cm)
118-1/2"(301 cm)
94-1/2"(240 cm)
94-1/2"(240 cm)
70-1/2"(179 cm)
46-1/2"(118 cm)
22-1/2"(57 cm)
66-1/2"(169 cm)
94-1/2" 46-1/2"(240 cm) (118 cm)
1-1/2"(3,8 cm)
1-1/2"(3,8 cm)
1-1/2"(3,8 cm)
PARTSREQUIRED:x5
x2
x2
x243" (7,6 cm)2 x 3 x 66-1/2" (5 x 7,6 x 169 cm)
2 x 3 x 46-1/2" (5 x 7,6 x 118 cm)
2 x 3 x 94-1/2" (5 x 7,6 x 240 cm)
FZ
NF
PR
2 Attach with 3" (7,6 cm) nails, two at each connection.
BEGIN
1̧ Orient parts on edge on floor as shown. Measure and mark.
PROFFSETSEAM
OFFSETSEAM
FZx5
PR
NF
NF
Centeron marks
BACK WALL
HINT:Foreasiernailingstandonframe.
![Page 28: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/28.jpg)
26
48"(122 cm)
3/4"(1,9 cm)
1-1/2"(3,8 cm)
3/4"(1,9 cm)
12"(30) cm
6"(15 cm)
Forsquareness,maintain3/4"and1-1/2"measurementalongpaneledges.
4
5
3
PARTSREQUIRED:
x1
x342" (5 cm)
3/8 x 48 x 72"(1 x 122 x 183 cm)
BEGINHERE
HINT:UseRKas1-1/2"gauge
2 x 3 x 13" (5 x 7,6 x 33 cm) as spacerx1 RK3/4"GAUGE
BLOCK
Therewillbeanoverhangattopandbottom
BACK WALL
Donotnailingroove.
Primedsideup
Fig.B
Fig.A
1-1/2" (3,8 cm)
1-1/2" (3,8 cm)
3/4" (1,9 cm)
3/4" (1,9 cm)
2Nails
2Nails
SQUAREEDGE
3/4"GAUGEBLOCK
Place the 48x72" panel onto wall frame with primed side up as shown. Note the lip and square edges.
Use the gauge block to mark the 3/4" measurement on the wall stud. Use RK as a 1-1/2" gauge block at top. Secure panel with two 2" nails in the corners (Fig.A).
Nail the panel using 2" nails 6" apart on edges and 12" apart inside panel.
Ensureyourwallframeissquarebyinstallingonepanelandsquaringframe.
Move to the opposite end. Using the long edge of the panel as a lever move the panel side-to-side until you have a 3/4" measurement on the wall stud. Secure corner with two 2" nails (Fig.B).
![Page 29: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/29.jpg)
27
1-1/2"(3,8 cm)
3/4"(19 mm)
48"(122 cm)
12"(30 cm)
6"(15 cm)
Flush
1-1/2"(3,8 cm)
48"(122 cm)
12"(30 cm)
6"(15 cm)
Flush
PARTSREQUIRED:
x2
x1922" (5 cm)
3/8 x 48 x 72" (1 x 122 x 183 cm)
2 x 3 x 13" (5 x 7,6 x 33 cm) as spacerx1 RK
HINT:UseRKas1-1/2"gauge
HINT:UseRKas1-1/2"gauge
3/4"GAUGEBLOCK
Therewillbeasideoverhang
attopandbottom
BACK WALL
LIPEDGE
SQUAREEDGE
LIPEDGE
Place center 48" panel on frame as shown with primed side facing up.NOTETHESQUAREANDLIPEDGES.
Nail using 2" nails 6" apart on edges and 12" apart inside panel.
6
Donotnailingroove.
Place end 48" panel on frame as shown with primed side facing up.NOTETHESQUAREANDLIPEDGES.
Nail using 2" nails 6" apart on edges and 12" apart inside panel.
7
You have fi nished building your back wall.FINISH
8
Primedsideup
Primedsideup
Forsquarenessmaintainflushand1-1/2"measurementalongpaneledges.
Forsquarenessmaintainflushand1-1/2"measurementalongpaneledges.
![Page 30: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/30.jpg)
28
22-1/2"(57 cm)
13-3/4"(35 cm)
46-1/2"(118 cm)
94-1/2"(240 cm)
61-3/4"(157 cm)
64"(162,5 cm)
68"(172,7 cm)
65-1/2"(166,3 cm)
Dimensions are to center of studs
Maintain dimension between studs
62-1/2"(158,8 cm)
14-1/2"(36,8 cm)
Flush
Flush
PARTSREQUIRED:x1
x1
x4
x1
x1
x183" (7,6 cm)
2 x 3 x 46-1/2" (5 x 7,6 x 118 cm)
2 x 3 x 94-1/2" (5 x 7,6 x 240 cm)
NF
PR
2 Nail using two 3" (7,6 cm) nails at each connection.
BEGIN
1̧ Orient parts on edge on floor as shown. Measure and mark.
2 x 3 x 14-1/2" (5 x 7,6 x 36,8 cm) FL
2 x 3 x 62-1/2" (5 x 7,6 x 158,8 cm)FN
2 x 3 x 68" (5 x 7,6 x 173 cm) OT
PRNF
FN FL
OTx4
FRONT WALL
HINT:Foreasiernailingstandonframe.
![Page 31: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/31.jpg)
29
Flush
94-1/2"(240 cm)
46-1/2"(118 cm)
7-7/8"(20 cm)
2-1/2"(6,4 cm)
2-1/2"(6,4 cm)
Flush
7-7/8"(20 cm)
PARTSREQUIRED: x4
OVERHANG PANELS
2 x 3 x 7-7/8" (5 x 7,6 x 20 cm) x2
x1
x1
3/8 x 7-7/8 x 94-1/2" (0,9 x 20 x 240 cm)
3/8 x 7-7/8 x 46-1/2" (0,9 x 20 x 118 cm)
Orient two overhang panels with the primed side up.
Attach panels flush to 2 x 3 x 7-7/8" (5 x 7,6 x 20 cm) using two 1-1/4" (3,2 cm) screws as shown.
4
3
Primedsideup
1-1/4" (3,2 cm)
![Page 32: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/32.jpg)
30
PARTSREQUIRED:
6
5
Screw into top plate using (14) 1-1/4"(3,2 cm) screws.
You have fi nished attaching your overhang.
Place overhang on wall panel, fl ush to back side and ends.
Place overhang fl ush to 2 x 3" (Fig.A.)
Keep overhang fl ush to 2 x 3" (Fig.B.)
Makesureoverhangsareflushto2x3"theentirelength
SeamFlush
x1
x1
Overhang
Overhang
Flush
DOOROPENING
Fig.AFig.B
FINISH
7
Flush
Flush
Approximately 10" (25,4 cm)
Approximately 9" (22,9 cm)
94-1/2"(240 cm)
46-1/2"(118,1 cm)
Two screws near seams
FRONT WALL
x161-1/4" (3,2 cm)
DOOROPENING
![Page 33: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/33.jpg)
31
3/4"(1,9 cm)
6" (15 cm)
Flush
48"(122 cm)
3/4"(1,9 cm)
12"(30 cm)
PARTSREQUIRED:
x1
x342" (5 cm)
FRONT WALL
Forsquareness,maintainflushand3/4"measurementalongpaneledges.
BEGINHERE
3/4"GAUGEBLOCK
3/4"GAUGEBLOCK
Therewillbeanoverhang
attopandbottom
Flushpanelunderoverhang
Fig.A.
2
3
1Donotnailingroove.
Primedsideup
Place the panel onto wall frame flush under overhang with primed side up as shown (Fig.A).
Use the gauge block to mark the 3/4" measurement on the wall stud. Secure panel with two 2" nails in the corners (Fig.B).
Nail the panel using 2" nails 6" apart on edges and 12" apart inside panel.
Ensureyourwallframeissquarebyinstallingonepanelandsquaringframe.
Move to the opposite end. Using the long edge of the panel as a lever move the panel side-to-side until you have a 3/4" measurement on the wall stud (Fig.C). Secure corner with two 2" nails.
Fig.C
Fig.B
3/4" (1,9 cm)
3/4" (1,9 cm)
2Nails
Flush
2Nails
![Page 34: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/34.jpg)
32
6"(15 cm)
64"(163 cm)
Flush
PT
Flush
3"(7,6 cm) Screws
Use one (1) PT across door openingto maintain 64" dimension
PARTSREQUIRED:
x2
x1
x49
x22" (5 cm)
3" (7,6 cm)
FRONT WALL
FINISH
7 You have fi nished attaching your front wall panels. Proceed to erect your walls.
Use PT as a brace to maintain 64" (163 cm) opening. Use two 3" screws to attach.
Continue installing panels primed side up fl ush under overhang (Fig.A).Note 1/4" (6,4 mm) offset on right panel.
Use 2" nails 6" apart on edges, and 12" apart inside panel.
4
76
5
2 x 3 x 96" (5 x 7,6 x 244 cm)
PT
3/8 x 15-7/8 x 72" (1 x 40 x 183 cm)
Therewillbeanoverhang
attopandbottom
Flushpanelsunderoverhang
Fig.A
LIPEDGE1/4"
(6 mm)
10 to12"
SQUAREEDGE
1/4"(6 mm)
Donotnailingroove.
Primedsideup
![Page 35: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/35.jpg)
33
PARTSREQUIRED:
x1
x6
x4
3" (7,6 cm)
3" (7,6 cm)
LEFT WALL INSTALLATION
2 x 3 x 96" (5 x 7,6 x 244 cm) PT
3" Nails(7,6 cm)
(2)3" Screws(7,6 cm)
6"(15 cm)
2" Nails(5 cm)
x18
LEFT
RK
PT
Fig.A
Fig.B
Angletohitfloorframe.
Nail2"nailsfirst.
2" (5 cm)
Attach RK, using three 3" (7,6 cm) nails as shown. Angle nails to hit fl oor frame (Fig.A).
First, nail lower edge of panel to fl oor frame using 2" nails 6" apart Angle nail to hit fl oor frame (Fig.A).
3
Secure back wall uprights to fl oor using two 3" screws (Fig.B).
4
5
You have fi nished standing your left wall.
FINISH
6
Center left wall assembly on the 96" (244 cm) fl oor dimension.
Use PT as a temporary brace. Secure with two 3" screws.
2
BEGIN
1
Donotnailingroove.
(2) 3" Screws(7,6 cm)
96"(244 cm)
![Page 36: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/36.jpg)
34
CENTER
PARTSREQUIRED:
x12
x2
BACK WALL INSTALLATION
x39
3" (7,6 cm)
3" (7,6 cm)
2" (5 cm)
FINISH
4
Nail down the bottom plate using two 3" nails between the wall studs.
Screw through the backwall trim into the top and bottom plates using one 3" screw (Fig.D,E).
Stand Back Wall Assembly on Floor. 1-1/2"(3,8cm)Paneloverhangisattop.
It is important to secure the Back Wall in the following order.
Nail the lower back wall corner to the side wall trim with one 2" (5 cm) nail (Fig.A).
Center back wall on fl oor, side-to-side.
Be sure the measurement between the panel edge and the trim is the same along the entire length. Then secure with one 2" nail in the upper corner (Fig.B).
Nail along the panel edge into the trim using 2" nails spaced 6" apart.
Nail along bottom of panel using 2" nails 6" apart. Angle nail to hit fl oor frame (Fig.C).
You have fi nished standing your Back Wall. Proceed to stand the Right Wall.
1
2
3
BEGIN¸
2"(5cm)Nail
1-1/2"(3,8cm)
2"(5cm)Nail
3"(7,6cm)Screw
6"(15 cm)
6"(15 cm)
3" (7,6 cm)nails
TrimPanel
Fig.A
Trim
Fig.C
Fig.B
Fig.D
Fig.E
SameMeasurement
3"(7,6cm)Screw
Trim
![Page 37: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/37.jpg)
35
6"(15 cm)
PARTSREQUIRED:
x6
x4
RIGHT WALL INSTALLATION
x31
3" (7,6 cm)
3" (7,6 cm)
2" (5 cm)
FINISH
4
Nail down RKusing three 3" nails on each as shown and secure center wall frame using two 3" screws (Fig.D).
Screw through the right wall trim into the top and bottom plates using 3" screws (Fig.E,F).
Stand right wall assembly on fl oor. It is important to secure the right wall in the following order.
Nail the lower back wall corner to the right wall trim. Secure with one 2" (5 cm) nail (Fig.A).
Center right wall on fl oor, side-to-side.
Be sure the measurement between the panel edge and the trim is the same along the entire length. Then secure with one 2" nail in the upper corner (Fig.B).
Nail along the panel edge into the trim using 2" nails spaced 6" apart.
Nail along bottom of panel using 2" nails 6" apart. Angle nail to hit fl oor frame (Fig.C).
You have fi nished standing your right wall. Proceed to stand the front Wall.
1
2
3
BEGIN¸
2"(5cm)Nail
Fig.A
Trim
CENTER
2"(5cm)Nail
3"(7,6cm)Screw
Trim Fig.B
Fig.E
Fig.F
SameMeasurement
6"(15 cm)
3" (7,6 cm)nails
BackPanel
Fig.C
Fig.D RK
(2)3"(7,6cm)
Screws
3"(7,6cm)Screw
Trim
![Page 38: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/38.jpg)
36
6"(15 cm)
6"(15 cm)
64"(162,6 cm)
Nail down the bottom plate using two 3" nails between the wall studs. (Fig.D). Screw through the front wall trim into the top and bottom plates using one 3" screw (Fig.E,F).
Repeat process to secure the left side of the front wall.
You have finished standing your front wall.4
x8 x4
x41
6"(15cm)
2"(5cm)Nail
Fig.B
Trim
Fig.A
CENTER
2"(5cm)Nail
TrimFig.C
Fig.D
SameMeasurement
2"(5cm)Nail
3"(7,6cm)Screw
PanelFig.E
3"(7,6cm)Screw
3"(7,6cm)Nails
Fig.F
Center front wall on floor side-to-side.
Check the 64" door opening is held before nailing. Nail the front wall flush to the floor using 2" nails 6" apart. Angle nails to hit floor frame (Fig.A).
Nail the lower side wall corner to the side wall trim with one 2" nail (Fig.B).
1
2
BEGIN
1̧
2" (5 cm) x26
3" (7,6 cm) 3" (7,6 cm)
FRONT WALL INSTALLATION
Be sure the measurement between the panel edge and the trim is the same along the entire length. Then secure with one 2" nail in the upper corner (Fig.C).
Nail along the panel edge into the trim using 2" nails spaced 6" apart.
3
Stand front wall on floor. It is important to secure the front wall in the following order.
![Page 39: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/39.jpg)
37
Flush toopening1-1/2"
(3,8 cm)
PARTSREQUIRED: x8
LV
3" (7,6 cm)
FRONT WALL
2 x 3 x 22-1/2" (5 x 7,6 x 57 cm) x2 LV
3" (7,6 cm) nails(2) at each connection
On inside of front wall attach LV flush to window opening using 3" (7,6 cm) nails as shown.
5
![Page 40: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/40.jpg)
38
PARTSREQUIRED: x4
FRONT WALL
3" (7,6 cm)
2 x 3 x 13" (5 x 7,6 x 33 cm)
2 x 3 x 68" (5 x 7,6 x 173 cm)
x1
x1
RK
OT
Angle 3"(7,6 cm)screw
Two 3"(7,6 cm) screw
Remove
OT
RK
Fig.A
Assemble RK to OT with one 3" (7,6 cm) screw (Fig.A).
Use OT and RK as a temporary brace to support top plate.Screw securely in place.
Remove temporary support in door opening.
One 3"(7,6 cm)screw
1-1/2"(3,8 cm)
6
7
FINISH
8
![Page 41: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/41.jpg)
39
x23" (7,6 cm)
x3
x1 3/8 x 5-3/8 x 5-1/2" (1 x 13,6 x 14 cm)
2 x 3 x 13" (5 x 7,6 x 33 cm) RK
101-3/8"(257,5 cm)
Importantmeasurement
DOOR
RAFTER JIG
FINISH
4
Make a rafter jig to make sure all rafters are assembled the same.
Measure from corner of backwall and RK (already installed) as shown.
Secure RK on the fl at square to back wall at measurement usingtwo 3" (7,6 cm) screws.
Attach a second RK on edge and 3/8" thick angle trim piece as shown (Fig.A).
You have fi nished building your rafter jig.
Requiredbecauserafterisunevenatbottom
2
3
BEGIN
1̧
PARTSREQUIRED:
RK
End Cap3/8 x 5-3/8 x 5-1/2"(1 x 13,6 x 14 cm)
3" (7,6 cm) screwmust drive in all the way
2-1/2"(6,4 cm)
RK
Fig.A
RK
![Page 42: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/42.jpg)
40
101-3/8”257,5 cm
NU
GLUE
2 x 4 x 65-5/8" (5 x 10 x 167 cm) Rafter
2 x 4 x 46-13/16" (5 x 10 x 119 cm) Rafter
ADx5
x10
x5
8 x 24" (20 x 61 cm) Gusset2" (5 cm)
x120
Shortedgetometalplateside
Shortedgetothisside
Endstouch
FINISH
6
You will assemble (5) rafters. Place rafter parts on Jig as shown.
You have fi nished building your rafters.
BEGIN
1̧
PARTSREQUIRED:
NU
NU
GussetAD
AD
RAFTERS
Apply glue to rafters where the gusset will fi t. Note short side of gusset. (Fig.A)2
Ends of rafters must touch together at the peak. Nail gusset to rafters using twelve 2" nails in pattern shown.
3
Flip over rafter assembly and repeat STEPS2-3 to attach second gusset to other side.4
Repeat STEPS1-4 to build FOUR additional rafter assemblies.5
Fig.A1/4" Gap(6 mm)
![Page 43: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/43.jpg)
41
Flush
Flush Flush
Flush
PARTSREQUIRED:
TRIM CAPS
x2
Attach primed side out and fl ush with soffi t, using two 1-1/4" (3,2 cm) screws on both sides, as shown.
2-5/8 x 5-3/8 x 5-1/2" (6,6 x 13,6 x 14 cm) 1 Left / 1 Right
x41-1/4" (3,2 cm)
You have fi nished your trim caps.
LEFTSIDE RIGHTSIDE
Install with primed side facing out
FINISH
2
BEGIN
1̧
![Page 44: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/44.jpg)
42
Install the back trim first, flush to back panel, trim, and panel edge as shown.
Secure using eight 1-1/4" (3,2 cm) screws 9" apart from inside shed.2
2 x 3 x 65" (5 x 7,6 x 165 cm)NRx2
Flush
Flush on trim
Flush to panel
NR
Flush to panel edge
PARTS REQUIRED: x161-1/4" (3,2 cm)
Flush
TRIM
BEGIN¸1
9" (22,9 cm)approximately
![Page 45: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/45.jpg)
43
Install the front trim, fl ush to peak and panel edge as shown.
Secure using six 1-1/4" (3,2 cm) screws from inside shed.
Repeat Steps for opposite Side Wall.
4
3
5
NQx22 x 3 x 46-7/8" (5 x 7 x 119 cm)
Flush to panel
Flush
NQ
Flush to peak
PARTS REQUIRED: x121-1/4" (3,2 cm)
TRIM
FINISH
6 You have fi nished attaching your Trim. Proceed to installing your Rafters.
9" (22,9 cm)approximately
![Page 46: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/46.jpg)
44
22-1/2"(57 cm)
24"(61 cm)
24"(61 cm)
24"(61 cm)
24"(61 cm)
22-1/2"(57 cm)
Dimensions are to center of rafters
Dimensions are from inside of panel
Flus h
DOOR
PARTSREQUIRED:
3" (7,6 cm)x20
FINISH
7
Mark top of wall frames to measurement shown.
Hold rafter end fl ush to back wall and overhang. Secure from under overhang using two 2" (5 cm) screw. (Fig.A)
Locate Rafter centered on marks.
Secure opposite end through panel into rafter end using one 2" (5 cm) screw (Fig.B)
Screw rafters at each end using two 3" (7,6 cm) screws as shown. (Fig.B,C)
Repeat steps to attach 5 rafters.
At each end(2) 3" (7,6 cm) screws
angle into 2 x 3"
2"(5 cm) Screw
Two 2"(5 cm)Screws
Fig.A
Fig.C Fig.B
You have attached your rafters. Proceed to attaching your soffi t trim.
3
2
4
5
6
BEGIN
1̧
ROOF
x15 2" (5 cm)
![Page 47: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/47.jpg)
45
72-3/8"(184 cm)
PARTSREQUIRED:2" (5 cm)
x16
5/8 x 3 x 72-3/8" (1,6 x 7,6 x 184 cm)
x2 KY
FINISH
3
2
Orient parts as shown and attach to ends of rafters, using two 2" (5 cm) fi nish nails (Fig.A).
You have fi nished your soffi t trim.
Trim is fl ush at ends to sidewall trim.
BEGIN
1̧
Flush
Fig.A
TRIM
KYFlushtotrimatends
![Page 48: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/48.jpg)
46
PARTSREQUIRED:2" (5 cm)
x22
x15/8 x 3-7/8 x 96" (1,6 x 9,8 x 244 cm)
FINISH
4
Position support fl ush with bottom edge of top plate and side wall panel and attach with 2" (5 cm) nails as shown.
Remove temporary brace after support is installed.
Use exterior-rated wood glue behind support. Apply to top plate and end of rafter
You have fi nished your door frame support.
2
3
BEGIN
1̧
Dooropening
RemoveAfter door
Frame supportIs attached
Flush
Glue
FlushFlush
DOOR SUPPORT
6"(15,2 cm)
![Page 49: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/49.jpg)
47
1/4"(6 mm)
20"(51 cm)
PARTSREQUIRED:2" (5 cm)
x10
5/8 x 20 x 96" (1,6 x 51 x 244 cm)
2 x 3 x 96" (5 x 7,6 x 244 cm)
x1
x1 PT
FINISH
3
Attach with 2" (5 cm) nails as shown.
Position bench top to PT fl ush at ends and maintaining 1/4" (6 mm) overhang, as shown (Fig.A).
You have fi nished building your workbench top.
2
BEGIN
1̧
PT
Fig.A
2x3temporarysupport
Flush at ends
5/8"(15,9 mm)
Flushatends
10-1/2"Approximately
WORKBENCH
2-1/2"(6,4 cm)
![Page 50: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/50.jpg)
48
1/4"(6 mm)
11-3/4"(30 cm)
PARTSREQUIRED:2" (5 cm)
x10
2 x 3 x 96" (5 x 7,6 x 244 cm)
x2
x27/16 x 11-3/4 x 96" (1,1 x 30 x 244 cm)
PT
Fig.A
Flush at ends
Flushatends
FINISH
3
Attach with 2" (5 cm) nails as shown. Repeat steps to build second shelf.
You will build two shelves. Position shelf to PT fl ush at ends and maintaining 1/4" (6 mm) overhang, as shown (Fig.A).
You have fi nished building your shelves.
2
BEGIN
1̧
SHELVES
7/16"(11,1 mm)
2-1/2"(6,4 cm)
PT
10-1/2"Approximately
![Page 51: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/51.jpg)
49
Fig.A
PARTSREQUIRED:3/4" (19 mm)
x13
1 x 3 x 96" (2,5 x 7,6 x 244 cm)
x1
x1
23-7/8 x 96" (61 x 244 cm) Peg Board
Flushatends
Flushatends
Flush
FINISH
3
Attach with 3/4" (19 mm) screws as shown.
Roughsideup
Roughsideup
Position pegboard to 1 x 3" fl ush at ends and edge, as shown (Fig.A).
You have fi nished building your pegboard.
2
BEGIN
1̧
PEGBOARD
8"Approximately
![Page 52: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/52.jpg)
50
20"(51 cm)
PARTSREQUIRED:
Place workbench into gap in side wall upright. Nail using 2" (5 cm) nails, as shown.
Level and attach KK to upright and workbench, using four 3" (,6 cm) screws as shown (Fig.A).
You will secure your workbench ends later. Proceed to attach your pegboard.
2
3" (7,6 cm)
x10
x1
x1
x4
2 x 3 x 24-1/16" (5 x 7,6 x 61 cm)KK
2" (5 cm)
BEGIN
1̧
Window
FINISH
3
Workbench2" (5 cm)
Nails
WORKBENCH
3" (7,6 cm)screws
KK
Fig.A
20"(51 cm)
10-1/2"Approximately
Angle top screwto hit KK
![Page 53: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/53.jpg)
51
2-1/2"(6,4 cm)
PARTSREQUIRED:
Attach RK at back corner of workbench into outside trim, using 3" (7,6 cm) screws, as shown.
Attach pegboard at top using (13) 1" (25 mm) screws as shown.
Place pegboard onto workbench with 1 x 3 Trim to bottom, facing out.
Anchor bottom of pegboard, using one 2" (5 cm) screw at center, and 3" (7,6 cm) screws at lower corners.
You have fi nished your pegboard. Proceed to attach your shelf .
3
2
4
3" (7,6 cm)x4
x2
x1
x13
x12" (5 cm)
BEGIN
1̧
Window
Flush
Window
2 x 3 x 13" (5 x 7,6 x 33 cm) RK 1" (25 mm)
3" (7,6 cm)
FINISH
5
2" (5 cm)Screw
1 x 3Trim to bottom
(13) 1" (2,5 cm)Screws across top
3" (7,6 cm)Screws
8"Approximately
RK
PEGBOARD
![Page 54: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/54.jpg)
52
11-3/4"(30 cm)
Window
Shelf
PARTSREQUIRED: x102" (5 cm)
You will screw the ends of workbench and shelf from outside of shed.2
BEGIN
1̧ Place shelf into gap in side wall upright. Attach using 2" (5 cm) nails, as shown.
x1
11-3/4"(30 cm)
10-1/2"Approximately
SHELVES
![Page 55: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/55.jpg)
53
59"(150 cm)
1"(2,5 cm)
12-5/8"(32 cm)
Measure fromcorner trim
Outside bottom ofwall panel
20-7/8"(53 cm)
34-1/4"(87 cm)
1"(2,5 cm)
3" (7,6 cm)Nail
PARTSREQUIRED: x83" (7,6 cm)
Measure and mark outside nail locations for workbench and shelf on back wallas shown.
Nail through marks on wall panel into ends of workbench and shelf supports. Repeat procedure at opposite ends of shelf and workbench.
Assistance may be required to hold shelf and workbench level.4
3
FINISH
5
SHELVES
![Page 56: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/56.jpg)
54
11-3/4"(30 cm)
PARTSREQUIRED: x6
x4
x2
1-1/4" (3,2 cm)
3" (7,6 cm)
3" (7,6 cm)
FINISH
4
2
3
BEGIN
1̧
Place shelf into gap in side wall upright. Attach using 1-1/4" (3,2 cm) screws from underneath, as shown.
From outside shed, nail through the wall panel into end of shelf using two 3" (7,6 cm) nails.
You have fi nished installing your shelf. Proceed to building your roof.
Install RK fl ush against top plate and outer wall panel. Attach using 3" (7,6 cm) screws, as shown (Fig.A).
Install RK in corner fl ush against top plate and outer wall panel.
RK
Fig.A
(3)1-1/4" screw
(3,2 cm)
(3)1-1/4" screw
(3,2 cm)
3" (7,6 cm) nails
Shelf
Gap
x1 2 x 3 x 13" (5 x 7,6 x 33 cm) RK
x1
11-3/4"(30 cm)
Youaneasilylocatenailslookingoverwall.
3" (7,6 cm)Screws
SHELVES
![Page 57: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/57.jpg)
55
ROOF PANELS
48"(122 cm)
PARTSREQUIRED: x42" (5 cm)
x1
2
3
BEGIN
1̧
3/4"GAUGEBLOCK
7/16 x 48 x 96"(1,1 x 122 x 244 cm)
Move to the opposite end. Using the long edge of the panel as a lever move the panel side-to-side until the top corner is flush to the peak (Fig.C) and there is 3/8" measurement to the gable trim (Fig.D). You may need to move your sidewall to get the 3/8" measurement. Secure panel with two 2" nails in the corners.
You must square the roof by attaching one panel fist. You will use the panels’ long edge as a lever to bring your roof into square. Commonly known as “racking”.
Roofpanelsmaycauseseriousinjuryuntilsecurelyfastened.
Attach the 48x96" panel with the rough side up (painted-grid lines side) with a 3/4" measurement on the rafter (FigA) and the panel flush at the peak (Fig.B). Secure panel with two 2" nails in the corners.
3/8"(9,5 mm)
GableTrim
Fig.D
Fig.C
TwoNails
3/4" (1,9 cm)
Fig.A
GaugeBlock
Flushatpeak
Flushatpeak
Fig.B
![Page 58: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/58.jpg)
56
22-1/2"(57 cm)
24"(61 cm)
24"(61 cm)
24"(61 cm)
24"(61 cm)
22-1/2"(57 cm)
3/8"(9,5 mm)
3/8"(9,5 mm)
12"(30,5 cm)
6"(15 cm)
PARTSREQUIRED:
x2
7/16 x 47-7/8 x 48"(1,1 x 122 x 122 cm)
x1082" (5 cm)
3/4"GAUGEBLOCK
x1
7/16 x 48 x 96"(1,1 x 122 x 244 cm)
Keep spacing between the center of the rafters at the lower edge of the panel and secure with one 2" nail into each rafter (Fig.E). Move to the top of the panel and keep spacing between the center of the rafters. Secure with one 2" nail into each rafter (Fig.E). Nail the roof panel using 2" nails 6" apart on edges and 12" apart inside panel. Attach 47-7/8x48" roof panel flush to first panel, flush at peak and with the 3/8" measurement on trim (Fig.F,G).
4
Move to the opposite side of the roof and repeat this process installing a 48 x 96” and 47-7/8 x 48” panel.
Note the panels edges are offset from the first panels installed.
Make sure panels are flush at the peak (FigH) and there is a 3/8” measurement at the gable trims (Fig.J).
Nail the roof panel using 2” nails 6” apart on edges and 12” apart inside panel.
5
GableTrim
NOTE: Measurements from inside of panels
Fig.F
Fig.H
Fig.J
Fig.G
Fig.E
2"NailsFlushatpeak
Flushatpeak
Flush
96"
48"
ROOF PANELS
![Page 59: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/59.jpg)
57
3/8"(9,5 mm)
3/8"(9,5 mm)
3/4"(19 mm)
PARTSREQUIRED:
x1
x1
7/16 x 18 x 96” (1,1 x 46 x 244 cm)
7/16 x 18 x 48" (1,1 x 46 x 122 cm)
x282" (5 cm)
3/4"GAUGEBLOCK
Attach 18x96" panel as shown fl ush to panels and 3/4" on rafter (Fig.A) and with 3/8" at the gable trim (Fig.B). Attach 18x48" roof panel fl ush to panels and with the 3/8" measurement on trim (Fig.B) and with 3/8" at the gable trim (Fig.C).
Nail the roof panels using 2" nails 6" apart on edges and 12" apart inside panel.
6
FINISH
7 You have fi nished installing your roof panels.
Fig.A
Fig.C
Fig.B
Flush
Flush
96"
48"
Flush
ROOF PANELS
![Page 60: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/60.jpg)
58
2 x 3 x 68" (5 x 7,6 x 173 cm) OT
2 x 3 x 69" (5 x 7,6 x 175,3 cm)
x1
x1
OO
OO
OT
Makesurespacerisattached.
Tightenscrewssecurely.
OFFSET
3"(7,6cm)screws
Bottomedgesflush
3/8"(1 cm)3/8"
(1 cm)
3/8"(1 cm)
3/8"(1 cm)
OFFSET
GREEN RED
Orient parts as shown on flat surface. 3/8"offsetistotop.Lookforred(right)andgreen(left)onhingeboard.
PARTSREQUIRED:
x1x1Left Door Right Door
BEGIN
1̧1
DOORS
3" (5 cm) x8
2 Attach temporary supports OO and OT with 3" screws in middle and at ends. Tighten securely.
HINT:Lookfor3/8"SPACER
attachedtodoors.
![Page 61: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/61.jpg)
59
PARTSREQUIRED: x133" (7,6 cm)
OO2 x 3 x 69" (5 x 7,6 x 175,3 cm)
OO
72"fromoverhang
OO
Fig.A
Center doors on mark as shown (Fig.B).4
Checkhingeboardisflushunderoverhang(Fig.C).
Remove temporary supports and check doors open properly.6
FINISH
7 You have fi nished installing your doors.
Screw hinge boards into wall supports and fl oor using ten 3" screws as shown. Makesurescrewsgointoframingandfloor (Fig.D,E).
5
3"(7,6cm)Screwsintothewall
supportandfloorframe.
Fig.B
Center3/8"measurementonmark.
Fig.D
Fig.C
3/8"(1 cm)
Fig.E
Angle3"(7,6cm)Screw
Flush
Attach temporary support OO as a ledger board for doors to rest on, using three 3" screws. Measure 72" down from underside of overhang (Fig.A).
Locate center of door opening and mark.
72"(182,9cm)frombottomofoverhangtotopofledgerboard
x1
3
DOORS
![Page 62: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/62.jpg)
60
CENTER CENTER
3/4" (1,9 cm)
Remove 3/8" spacers from doors.
Reinforce the door trim using 3/4" screws through door panel into trim (Fig.A).Locate screws as shown (Fig.B). Use two screws at seams.
Fig.B
Screwintoframing.
TwoScrews
DoorTrim
HingeBoard
Fig.A
DoorPanel
You have fi nished securing your door trim. FINISH
4
BEGIN
2
1
DOOR
PARTSREQUIRED: x42
Center metal threshold between doors and secure using eleven 3/4" special coating screws into fl oor as shown (Fig,C).
3
Fig.C
x11Bagged separately/special coating64" Metal Threshold
x1
(11)Specialcoatingscrews
![Page 63: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/63.jpg)
61
OO
Screws2"
(5cm)
x14
1"(2,5 cm)
OFFSETScrews
2"(5cm)
1"(2,5 cm)
OFFSET
Secure OO using seven 3" screws through outside trim into OO (Fig.B)2
Fig.A Fig.B Fig.C
CenterOOindooropening.
11" (28 cm)Approximately
PARTSREQUIRED:
2 x 3 x 69" (5 x 7,6 x 175 cm)x2
x142" (5 cm)
DOOR WEATHERSTRIP
OO
You have fi nished installing your door weatherstrips.
BEGIN
With left door closed, center a weatherstrip OO vertically on the left door in the door opening (Fig.A). OO will offset the left door 1" OUT past the door trim 1" (Fig.B).
1
FINISH
5
On right door center OO vertically in door opening (Fig.A). OO will offset the right door 1" IN from the door trim (Fig.C).
3
Secure OO using seven 3" screws through outside trim into OO (Fig.C).4
![Page 64: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/64.jpg)
62
PARTSREQUIRED:
DOOR HARDWARE
x2
3/4" (1,9 cm) x8
35-1/2"(90 cm)
Installonrightdoor.
x1
3/4" (1,9 cm) x7
Fig.B
3/4"(1,9cm)Screwx7
3/8" (9 mm) Drill Bit
OO
OO
Fig.A
Fig.B
FlushonOO.
FlushonOO
Drill3/8"holein-linewithbolt.
Drill3/8"holein-linewithbolt.
LEFTDOOR
BEGIN
With door closed mark hole locations for bolts to extend into.
HINT: Extend bolts to leave marks in wood. Tap bolts with hammer. Drill 3/8" holes deep enough for each bolt to slide into.
3
2
Mount one barrel bolt fl ush at top of OO on left door using 3/4" screws as shown (FigA).
Mount the second barrel bolt fl ush at bottom of OO on left door using 3/4" screws as shown (FigB).
1
HINT: With door closed extend bolt and tap with hammer to leave a mark in wood for drilling.
Secure hasp and latch as shown using 3/4" screws. You have fi nished mounting your door hardware.
FINISH
4
![Page 65: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/65.jpg)
63
LevelFlush
Flush
Glue
Rafter centeredover door opening.
Glue
ROOF
PARTSREQUIRED: x63" (7,6 cm)
x12 x 3 x 68" (5 x 7,6 x 173 cm)
OT
FINISH
3
2
BEGIN
1̧ Position and level OT on rafter that is centered over door opening.
Glue OT and attach with 3" (7,6 cm) nails as shown.
You have fi nished your roof. Proceed to attaching your doors.
OT
![Page 66: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/66.jpg)
64
1/4"(6,4 mm)
3-1/2"(8,9 cm)
3-1/2"(8,9 cm)
1" (25 mm)
PARTSREQUIRED:
FINISH
4
BEGIN
1̧ Position parts primed side-down on fl oor, as shown. You will build two shutters the same.
You have fi nished building your window shutters. Proceed to install your window.
Installwithprimedsidefacingdown
5/8 x 3 x 25" (1,6 x 7,6 x 63,5 cm)
5/8 x 3 x 8" (1,6 x 7,6 x 20 cm)
x6x4
KW
KV
KVx2KWx3
Flush
Flushbothsides
Flushbothsides
2
3
Attach using 1" (25 mm) screws as shown.
Repeat steps to build your second shutter.
Primedsidedown
WINDOW SHUTTERS
x12
![Page 67: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/67.jpg)
65
CENTER
CENTER
CENTER
CENTER
WINDOW SHUTTERS
1-1/4" (3,2 cm)
PARTSREQUIRED:
BEGIN
1̧ Seal windowwith high-quality exterior-grade caulk.
2
3
Attach window using four 1-1/4" (3,2 cm) screws as shown.
Mark center of window frame as shown.
Window23-3/4" x 16-1/2"(63 x 42 cm)
x1x4
HINT: Caulk behind frame near edge before installing.
![Page 68: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/68.jpg)
66
KX
KX
WINDOW SHUTTERS
3/4" (19 mm)
CENTER
Flush Flush
Flush
2" Finish nails
2" Finish nailsinto wall frame
3/4" Screws from inside
Flush
Mark
Mark
FINISH
7
PARTSREQUIRED:
Locate one shutter centered on marks as shown.
x6
x20
5
6
4
First, attach shutter using a 2" fi nish nail at "dot". Nail into wall frame inside.
Then, from INSIDE of the shed, use three 3/4" screws to secure the shutter indicated at "X".
Repeat steps to attach shutter on opposite side.
Locate KX centered on mark and fl ush to shutters as shown. Attach using 2" fi nish nails. Nail into window frame inside.
You have fi nished installing your window and shutters.
2" (5 cm)
5/8 x 3 x 21-3/4" (1,6 x 7,6 x 55 cm)x2 KX
x2
8-3/8"(21,3 cm)
8-3/8"(21,3 cm)
12-1/2"(31,8 cm)
12-1/2"(31,8 cm)
![Page 69: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/69.jpg)
67
DOOR TRIM
PARTSREQUIRED:
5/8 x 3 x 14" (1,6 x 7,6 x 35,5 cm)x8
x163/4" (19 mm)
BEGIN
1̧ Position parts on lower pane of Door Panel, as shown.
2 Attach each using two 3/4" (19 mm) screws as shown.
![Page 70: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/70.jpg)
68
• Install felt flush to all roof edges overlapping 3". Use minimal amount of roofing nails to hold in place.
OK to overlap at ridge.3"OVERLAP
Flush
Flush
PARTSREQUIRED:
• Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim.
• Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: • Bottom edge of all siding and trim • Inside of doors and all 4 edges
Note: Prime all un-primed exterior wood before painting. (Follow directions provided by manufacturer.)
PAINT & CAULK- NOT INCLUDED -
ROOF FELT- NOT INCLUDED -
DRIP EDGE- NOT INCLUDED -
Snip bottom side of drip edge andbend over to other side of roof.
(Follow directions provided by manufacturer.)
• Install drip edge over roof felt on gable side and under roof felt on eave side (Fig.A).• Do not use nails on side of drip edge that hangs over side of building. • Only nail top of drip edge as shown.
Edgeflushtotrim.
Fig.A
Dripedge Dripedge
Rooffelt
![Page 71: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/71.jpg)
69
•Followdirectionsprovidedbymanufacturerandtheseinstructions.
SHINGLES - NOT INCLUDED -
Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle. Starterrowmustbestraightandlevelallthewayacrosswithloweredgeofroofdeck.NOTE: If you have installed drip edge install shingles flush to drip edge.
BEGIN
1
TABSUP
Shingleoverlapsroofdecking.
1"(2,5cm)overhangpastroofdeck.
1"(2,5cm)overhangorflushwithdripedge.
(4)Nails
BACKOFSHED
FRONTOFSHED
NEVERDRIVEFASTENERSINTOORABOVESEALINGSTRIPS.
Familiarizeyourselfwitha3-TabShingle.
SHINGLE NAIL PATTERN
1"(2,5 cm)
NAILS
Sealing Strip 1"(2,5 cm)
1/2"(1,3 cm)
Full Rain Slot
Half A Rain Slot
NotchNotch
![Page 72: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/72.jpg)
70
SHINGLES continued...
Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge.22
FRONTOFSHED
BACKOFSHED
Notch-or-
DripEdge
Notch
RoofDeck
1"(2,5 cm)
Flush with starter row.
Flush with starter row.
Continue installing rows of shingles by staggering at front.
4
Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row.
3
1"(2,5 cm)
1"(2,5 cm)
BACKOFSHED
FRONTOFSHED
FRONTOFSHED
Flushwithrainslots. Flushwithrainslots.
Notch
Notch
![Page 73: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/73.jpg)
71
You have fi nished shingling your roof. Proceed to capping the ridge.FINISH
9
Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife.
Repeat steps 1 - 7 to shingle the opposite side of your roof. Trim shingles at ridge.
Once both sides are shingled you need to trim ends. Strike a chalk line 1" from edge.
Using your shingle hooked blade carefully cut shingles along chalk line.
5
6
7
8
SHINGLEScontinued...
•Ifmorethan5"torainslotyoumustinstallanotherrowofshingles.
5"(12,7 cm)or less.
5"(12,7 cm) MAX.
Topofrainslot.
CutOff.CUT
![Page 74: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/74.jpg)
72
SHINGLES - RIDGE CAP
• You will finish off the top of the roof with a ridge cap made from shingles.
Note: • You will need about 29-31 cut pieces.
Cut shingles into THREE pieces. Hint: Use cut-off pieces first.
Scoreshingle,thensnap-offangledcut.
Install first ridge cap flush to shingles at front, as shown.
Install second ridge cap 5" back, as shown.
2
BEGIN
1
2" (5 cm)
2" (5 cm)
2" (5 cm)
2" (5 cm)
2" (5 cm)
2" (5 cm
Topofslot.WeatherSeal
Flush
(1)Nailpersidethroughweatherseal.
(1)Nailpersidethroughweatherseal.
5" 12,7 cm
FRONTOFSHED
Flush
29to31Pieces
3
![Page 75: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/75.jpg)
73
SHINGLES - RIDGE CAPcontinued...
Continue installing ridge cap to back of roof.
Make sure there is 4" between the shingle-color and edge of shingles.
When you have 4" minimum of shingle color cut one piece to cap your roof.
Install fl ush to shingles.
4
5
6
7
(2)Nailsperside.
You have fi nished your ridge cap.FINISH
8
Cutattopofrainslot.
Flushtoshingles
Trimcapoffflushtoshingles
Cap
4"(10 cm)
![Page 76: Call Us First! DO NOT RETURN TO STOREheartlandind.com/wp-content/uploads/2015/08/... · STRATFORD 12' x 8' (366 x 244 cm) ASSEMBLY MANUAL BEFORE YOU BEGIN VALUE SERIES 16665 ... To](https://reader035.vdocuments.us/reader035/viewer/2022070805/5f03957c7e708231d409c55c/html5/thumbnails/76.jpg)
74
WARRANTYBackyard Storage Solutions, LLC warrants the following:1. Every product is warranted from defects in workmanship and manufacturing for one year.2. All hardware and metal components are warranted for two years.3. Trim is warranted for 10 years.4. Waferboard siding and sheathing is warranted for two years.5. SmartSide™ siding is warranted for 10 years on all Marco series buildings and 15 years on all Premier Series buildings.6. Timber series buildings’ siding and trim are warranted for 10 years.7. Solar Shed windows are warranted for 1 year.8. Cedar lumber is warranted for 15 years.9. Cedar doors and Cedar Garden Center are warranted for 10 years.10. Metal roof is warranted for 25 years.
Backyard Storage Solutions, LLC will repair, replace or pay for the affected part. In no event shall Backyard Storage Solutions, LLC paythe cost of labor or installation or any other costs related thereto. All warranties are from date of purchase. If a cash refund is paid on anaffected part, it will be prorated from the date of purchase.
CONDITIONSThe warranty is effective only when:1. The unit has been erected in accordance with the assembly instructions.2. The unit has been properly shingled and painted or stained and reasonably and regularly maintained thereafter.3. The failure occurs when the unit is owned by the original purchaser.4. Backyard Storage Solutions, LLC has received the warranty registration card within thirty (30) days of purchase and notification
of the failure in writing within the warranty period specified above.5. Backyard Storage Solutions, LLC has had reasonable opportunity during the sixty (60) days following receipt of notification
to inspect and verify the failure prior to commencement of any repair work.
REQUIREMENTSStorage Buildings & Pla yhouse sTo validate your warranty, it is necessary to properly maintain your Backyard Storage Solutions, LLC unit; shingle the roof and paint or solid-colored stain the siding using 100% acrylic latex exterior product with a minimum of two (2) coats within thirty (30) days of assembly;
above all doors and all horizontal and vertical trim boards; paint and seal all exposed edges, sides and faces of SmartSide™ andwaferboard siding to include all exterior walls and all sides and all edges of doors.
Gazebos, Pergolas & Timber BuildingsTo validate your warranty, it is necessary to properly maintain your Backyard Storage Solutions, LLC unit. This includes treating all of theexposed cedar and pine surfaces on your gazebo or timber building with an exterior grade wood preservative, an exterior oil-basedsemi-transparent stain, an acrylic latex exterior paint or an acrylic latex solid color exterior stain within 30 days of assembly and as neededthereafter to maintain your warranty.
Keep vegetation trimmed away from building and make sure siding panels and trim do not come in contact with masonry or cement. Theminimum ground clearance for siding must be one half inch (½ inch) from concrete slab or two and one half inches (2 ½”) from the groundwhen building is erected or constructed on a treated wood floor kit. Water from sprinklers must be kept off unit. In no event will Backyard
events, acts or omissions beyond our control including, but not limited to, misuse or improper assembly, improper maintenance (whichleads to rot or decay) and acts of God. Backyard Storage Solutions, LLC will not be held responsible for any labor costs incurred
to construct your unit. This warranty gives you certain specific rights that vary from state to state.
CLAIM PROCEDURETo make a claim under this warranty, you can either call 1-888-827-9056 or prepare a letter. Please have ready the information below whenyou call or include the information when writing:1. The model and size of the product.2. A list of the part(s) for which the claim is made.3. Proof of purchase of the Backyard Storage Solutions, LLC item, as shown on the original invoice.4. Run code, as listed on the yellow warranty card enclosed in the product package.
Mail the above information to: Backyard Storage Solutions, LLC Attn: Customer Service 1000 Ternes Monroe, MI 48162
Limited ConditionalWarranty *
*WARRANTY TERMS MAY VARY OUTSIDE THE U.S.A.IMPORTANT: This is y our warranty cer tificate.Please complete and mail your warranty card to pr operl y validate y our warranty .
Storage Solutions, LLC be responsible for any indirect, incidental, consequential or special damages nor for failure(s) that are caused by
eventually
caulk