2002.10.10 / UNIQ-GB 1
CALIBRATOR UNIQ Technical FactorsWeighing technique W signals :
1,67 / 1.000.000 V/Kg (1,67 µV/Kg)
Uploading 50 times / sek.6 Tons load cell divided into 110.000 units, identical to 55 gram/ unitLoad cell physical bending: 2/10 mm / 6.000 Kg. (0,00003333 mm/Kg)
Automatic temperature correction from -20ºC to +70ºC
Reg. technique Actuator control :Thermal protection against overload and over current. CALIBRATOR UNIQ HW dimensioned to maximum long time current of 39 API controlled actuator / never goes too far / deceleration at end goal.
Trend Integrated intelligence :Integrated CAN-bus controller built in . Bosch developer to car industryAutomatic fault corrections by ex. electrical noisePrepared for adding extra equipment ex. Extra actuator etc.
Communication Electronic:RS 232 seriel communication w/ 2 times serial ports, integrated in one plugRS 232 plug w/ 1 stk. integrated CAN bus communicationAMP 4 pol f/ CAN communication – f/ ex. ISO 11783
Power System flexibility : Wide power area with wide intervals – stabil supply: 10 – 16 VTemperature area: -20º C / +70º CSW-programmable digital inputs (Speed, PTO, Tank and Flow)Very fast adapted inputs – speed up to ”MACH 2,5”When booting the system automatically optimizes all internal power suppliesInternal 2 Mb ramRISC 32-bit processor (Automotiv app.), 512 Kb flash, 32 Kb F-ram (logfile)
2002.10.10 / UNIQ-GB 2
①CALIBRATOR UNIQ System - complete
⑩
⑥
AL TEKNIK6 Ton
AL TEKNIK6 Ton
Red AMP no. 18 Power (-)Yellow AMP no. 19 Power (-)White AMP no. 20 Power (+)Green AMP no. 21 Power (+)Brown AMP no. 08 POT BBlue AMP no. 09 POT WBlack AMP no. 10 POT T
⑩
Yellow AMP no. 12 W-Signal (-)Brown AMP no. 11 W-Power (+)White AMP no. 17 W-Signal (+)Green AMP no. 06Shield AMP no. 13
Brown AMP no. 16 PTO (+)White AMP no. 15 Trend (-)/PTO (-)Green AMP no. 01 Trend (+)Yellow AMP no. 22 Trend-SignalPink AMP no. 14 Tank- ReferenceGrey AMP no. 03 Tank-SignalBlue AMP no. 07 Free ⑥
Green AMP no. 01Grey AMP no. 03Green AMP no. 06Blue AMP no. 07Brown AMP no. 08Blue AMP no. 09Black AMP no. 10Brown AMP no. 11Yellow AMP no. 12Shield AMP no. 13Pink AMP no. 14White AMP no. 15Brown AMP no. 16White AMP no. 17Red AMP no. 18Yellow AMP no. 19White AMP no. 20Green AMP no. 21Yellow AMP no. 22
②③
④
⑤
⑨
⑧
⑤
Reg. Actuator, LA 32⑩
Load cell 6 Ton⑨
PTO-sensor – Reedw/ magnetic sensing⑧
Trend Actuator, LA 12Trend UNIQ w/ CAN-comm.⑦
Connectionboxw/ 9 + 1 connections⑥
AMP 22 pol – Femalew/ Fix screw⑤
AMP 22 pol – Malew/ bracket and lid④
Speed Sensor – Induktivw/ Ferredic iron sensing③
Fuse part w/ 8 Amp. fuse± 12 V (Min. 10 V – Max. 14 V)
②
CALIBRATOR UNIQ①PARTPOS
⑦
2002.10.10 / UNIQ-GB 3
CALIBRATOR UNIQ Connection-box
Load cell(s)
PTO
Trend
Tank
1
6
Shield
2
3
4
5
7
89
W-Power (-)Green
W-Signal (+)White
W-Power (+)Brown
W-Signal (-)Yellow
PTO-Signal (+)Brown
PTO-Signal (-)Blue
Trend-signalBlack
AMP no. 6Green
AMP no. 17White
AMP no. 11Brown
AMP no. 12Yellow
AMP no. 16Brown
AMP no. 15White
AMP no. 1Green
AMP no. 22Yellow
Trend (-)White
Tank (-)Blue
Trend (+)Red
Tank (+)Brown Tank-Signal
BlackAMP no. 14PinkAMP no. 3Gray
Shield