cable lists for rnc2600_ru20

42
DN70539915 Issue 2-0 © Nokia Siemens Networks 1 (42) WCDMA RNC Cable Lists for RNC2600

Upload: bdtptit

Post on 01-Jun-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 1/42

DN70539915Issue 2-0

© Nokia Siemens Networks 1 (42)

WCDMA RNC

Cable Lists for RNC2600

Page 2: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 2/42

Cable Lists for RNC2600

2 (42) © Nokia Siemens Networks DN70539915Issue 2-0

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or 

transmitted in any form or means without the prior written permission of Nokia SiemensNetworks. The documentation has been prepared to be used by professional and properlytrained personnel, and the customer assumes full responsibility when using it. Nokia SiemensNetworks welcomes customer comments as part of the process of continuous developmentand improvement of the documentation.

The information or statements given in this documentation concerning the suitability, capacity,or performance of the mentioned hardware or software products are given “as is” and allliability arising in connection with such hardware or software products shall be definedconclusively and finally in a separate agreement between Nokia Siemens Networks and thecustomer. However, Nokia Siemens Networks has made all reasonable efforts to ensure thatthe instructions contained in the document are adequate and free of material errors andomissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks,explain issues which may not be covered by the document.

Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NOEVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THISDOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TOSPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESSINTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THEUSE OF THIS DOCUMENT OR THE INFORMATION IN IT.

This documentation and the product it describes are considered protected by copyrights andother intellectual property rights according to the applicable laws.

The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademarkof Nokia Corporation. Siemens is a registered trademark of Siemens AG.

Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

Copyright © Nokia Siemens Networks 2009. All rights reserved.

Page 3: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 3/42

Contents

DN70539915Issue 2-0

© Nokia Siemens Networks 3 (42)

Contents

1 About Cable lists for RNC2600............................................................ 51.1 Related documentation .......................................................................... 5

2 Identifying subracks, connectors and cables.................................... 62.1 Numbering system of the subrack shelves and cable connectors........... 62.1.1 Locking pegs.......................................................................................... 82.2 Categories of cables .............................................................................. 82.2.1 Interconnection cables ........................................................................... 82.2.2 Site cables ............................................................................................. 92.3 Identifying cables ................................................................................. 102.4 Cabling lists ......................................................................................... 12

3 Intracabinet cables for the RNAC cabinet ........................................ 133.1 RNAC power cables............................................................................. 133.2 RNAC control and bus cables .............................................................. 143.3 RNAC LVDS cables ............................................................................. 183.3.1 RNAC synchronization and LVDS cables............................................. 183.4 RNAC LAN cables ............................................................................... 203.5 RNAC alarm and synchronization cables ............................................. 223.6 RNAC protection switch cables ............................................................ 24

4 Intracabinet cables for the RNBC cabinet ........................................ 264.1 RNBC power cables............................................................................. 264.2 RNBC control and bus cables .............................................................. 274.3 RNBC protection switch cables ............................................................ 28

5 Intercabinet cables from RNBC to RNAC ......................................... 315.1 Intercabinet HMS and timing cables..................................................... 315.2 Intercabinet SWU LAN cables .............................................................. 345.3 Intercabinet SFU LVDS lines................................................................ 35

6 Physical cable equipping positions and SW portconnection coordinates..................................................................... 39

Page 4: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 4/42

Cable Lists for RNC2600

4 (42) © Nokia Siemens Networks DN70539915Issue 2-0

Summary of changes

Issue 2-0

Figure 4 Routing of line timing cables CA_060 – CA_062 and CA_067 –CA_069  updated.

Issue 1-0

First issue.

Page 5: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 5/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 5 (42)

1   About Cable lists for RNC2600

This document provides a list of all the intercabinet and intracabinetcabling installed in the RNAC and RNBC cabinets in RNC2600.

1.1 Related documentation

Hardware configuration manual

For more detailed information on RNC cabinet mechanics, seeEquipment Lists for RNC2600 .

Engineering description

For basic information on, for example, RNC installation planning, seeWCDMA RNC Engineering Description.

Installation manual

For detailed information on RNC hardware installation, see  Installing theMGW and RNC .

Page 6: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 6/42

Page 7: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 7/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 7 (42)

IPA2800 RNC / MGW cabinet,

seen from the front

Slot position number 

CA_020 OMU 0 1.0B 16.4X DU 0-0 1.0B 17.3H CJA002 SCSI bus 0

CA_021 OMU 0 1.0B 16.5D DU 0-0 1.0B 17.3O CJB002 SCSI bus 0

FU Connector FU Connector Type Use

Equip No.   CABLE FROM CABLE TO

Connector Type ACE

1.0B 16.4X

1   2   3F = FRONTB = BACK   4

DN05158647

Subrack in position 1 seen from the rear 

 A

C

E

G

J

L

N

P

R

T

V

X

Z

Z ABCDEF

3

1

2

3

4

5

B

 A

B

 A

B

Connector Type BDF

B

D

F

H

K

M

O

Q

S

U

Y

Z ABCDEF

4

12345678910111213141516171819

2

Note

1

Figure 1 Notations used in the cabling lists

Page 8: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 8/42

Cable Lists for RNC2600

8 (42) © Nokia Siemens Networks DN70539915Issue 2-0

2.1.1 Locking pegs

Each connector is provided with locking devices (for example locking

pegs or screws) that fasten the cable connector securely to the subrack.The connector locking pegs are placed in the same positions in eachsubrack type, regardless of the subrack's position in a given cabinet. If the subrack includes supplementary locking pegs, they can be used asspare parts.

1

2

3

4

5

12345678910111213141516171819

XXX

X

XXXXX

XXX

XXXXXX

XXXXX

XXXXX

XXXXX

XX

X

X

X

XXXXX

XXXXX

XXXX

XXXXX

XXXXX

XXXXX

X XX

X   XXXXX

X

XXX X

XX

XXX

XXX

XX

X X   X X

XXXXX

XXXXX

XXXXX

XXXXXXXXXX

XXXXX

XXXXX

XX

XXXXXXXXXX

XXXXXXXXXX

XXXXXXXXXX

XXXXX

XXXXX

XX

X

XXXXX

XXX

XX

XXXXX

XX

Figure 2 Locking pegs’ positions

2.2 Categories of cables

The cabling of an exchange consists of interconnection cables(intermediate cables) and site cables (outgoing cables) as describedbelow.

2.2.1 Interconnection cables

The interconnection cables comprise all the cables inside each cabinetand between the cabinets which form a single exchange. The

Page 9: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 9/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 9 (42)

interconnection cables are cut to length and equipped with connectors.They include:

  Power distribution cables

  ATM connection cables

  Hardware Management Bus cables

  Synchronization and timing cables

  SCSI cables between storage units and their master units

  LAN/Ethernet cables

Intracabinet cables

The interconnection cables between different subracks located in the

same cabinet run from one subrack to another along the walls andcabling shelves of the cabinet. These cables are delivered completelyinstalled in the cabinets.

Intercabinet cables

The interconnection cables running between different cabinets are leddirectly from one cabinet to another on cable shelves located behind thecabinets. These cables must be installed at the site. The interconnectioncables are delivered as prefabricated cable sets.

2.2.2 Site cables

The site (outgoing) cables are all the cables that leave the exchange.They include:

  Trunk circuit cables from the network interfaces

  Power supply cables

  Grounding cables

  I/O cables

  TCP/IP cables to the Network Management system

The site cables are connected directly to the plug-in units, or to the backinterface units located at the rear of the cabinets. These cables must beinstalled at the site.

The site cables can be routed to the environment through the opening atthe bottom (raised floor installations) or top plate (normal installation) of the EC216. These cables must be installed at the site.

Page 10: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 10/42

Cable Lists for RNC2600

10 (42) © Nokia Siemens Networks DN70539915Issue 2-0

 All the cables entering the cabinet(s), except for the DC power feedcables, must have protective wires which are grounded to the frame of the exchange at the connectors in the cabling cabinets.

The site cables are not delivered in sets and vary in length depending onthe delivery. They must be ordered separately and are designed for each delivery. They are not included in the standard documentation.

2.3 Identifying cables

The equipping reference is located on the Cable Identification Label (b inFigure 3 Example of the marking system for the cables below).

The first part of the equipping reference specifies the cable list where thecable is mentioned. The second part gives the sequence number withinthat list.

The equipping reference of the cables is based on the cabinet (type)name in which the cable is connected. There are two main groups:

1. Cables whose both ends are connected in the same cabinet(intracabinet cables).

The equipping information is expressed: [Cabinet type_sequencenumber].”CA_123”. There may be several identical cables of this type ina single Network Element, but only one within the same cabinet.

2. Cables which originate from one cabinet and end in another (intercabinet cables).

The equipping information is expressed: [Cabinet type, cabinet index_ sequence number].”CBn_123”. There may be only one of eachindividual cable of this type in a single Network Element.

 All intercabinet cables connect from RNBC to RNAC.

The cabinet, where the cable starts in, determines the [cabinet type,cabinet index] part of the equipping reference.

Page 11: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 11/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 11 (42)

DN99632985

b) Cable identification label

) A letter 'C' after the number indicates centimetres (cm) instead of decimetres (dm).

Example

a) Equipping number of cable, e.g.

Sequential number 

ITEM NAME:CJA002 LOT ID: 3G9912

 Alias name

Fixed length (dm)Item identifier 

Separators

Factory symbol

Year / Week

Interchangeability / version

C19179 .......... A01

CA-020

CA_020

a)

b)

CA_020

a)

Figure 3 Example of the marking system for the cables

Page 12: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 12/42

Page 13: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 13/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 13 (42)

3   Intracabinet cables for the RNACcabinet

This chapter presents the intracabinet cabling for the RNAC cabinet inRNC2600.

Single cabinet figures show the RNAC cabinet. Two-cabinet figuresshow the RNAC and RNBC cabinets from left to right, unless otherwiseindicated.

Tip

The lengths of intracabinet cables in deliveries may be different fromthose given in this document.

3.1 RNAC power cables

Table 2 RNAC CPD120-A power cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_001 A CPD120 UB2 0.10B P1 A PD30 0 1.0B 10_PP2 CVXB004 POWER

CA_002 A CPD120 UB1 0.0B P1 A PD30 0 1.0B 10_PP1 CVXB004 POWER

CA_003 A CPD120 UB2 0.10B P2 A PD30 1 2.0B 10_PP2 CVXB015 POWER

CA_004 A CPD120 UB1 0.0B P2 A PD30 1 20B 10_PP1 CVXB015 POWER

CA_005 A CPD120 UB2 0.10B P3 A PD30 2 3.0B 10_PP2 CVXB020 POWER

CA_006 A CPD120 UB1 0.0B P3 A PD30 2 3.0B 10_PP1 CVXB020 POWER

CA_007 A CPD120 UB2 0.10B P4 A PD30 3 4.0B 10_PP2 CVXB027 POWER

CA_008 A CPD120 UB1 0.0B P4 A PD30 3 4.0B 10_PP1 CVXB027 POWER

Page 14: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 14/42

Cable Lists for RNC2600

14 (42) © Nokia Siemens Networks DN70539915Issue 2-0

3.2 RNAC control and bus cables

Table 3 RNAC control cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_010 A FTRA 1 1.0B A PD30 0 1.0B 10_P1 CXVB18C CONTROL

CA_011 A FTRA 2 2.0B A PD30 1 2.0B 10_P1 CXVB18C CONTROL

CA_012 A FTRA 3 3.0B A PD30 2 3.0B 10_P1 CXVB18C CONTROL

CA_013 A FTRA 4 4.0B A PD30 3 4.0B 10_P1 CXVB18C CONTROL

Table 4 RNAC OMU and OMS SCSI bus 0/1 cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_075 A OMU 0 1.0B 16.4P A WDU 0 (OMU) 1.0B 14.2P CHS006 SCSI bus 0

CA_076 A OMU 0 1.0B 16.4V A WDU 0 (OMU) 1.0B 14.2V CHS006 SCSI bus 0

CA_077 A OMU 0 1.0B 16.5B A WDU 0 (OMU) 1.0B 14.3B CHS006 SCSI bus 0

CA_078 A WDU 0 (OMU) 1.0B 14.3H A OMU 1 2.0B 16.4P CHS012 SCSI bus 0CA_079 A WDU 0 (OMU) 1.0B 14.3O A OMU 1 2.0B 16.4V CHS012 SCSI bus 0

CA_080 A WDU 0 (OMU) 1.0B 14.3U A OMU 1 2.0B 16.5B CHS012 SCSI bus 0

CA_081 A OMS 1.0B 6.4P A HDD 0 (OMS) 1.0B 14.4P CHS005 SCSI bus 0

CA_082 A OMS 1.0B 6.4V A HDD 0 (OMS) 1.0B 14.4V CHS005 SCSI bus 0

CA_083 A OMS 1.0B 6.5B A HDD 0 (OMS) 1.0B 14.5B CHS005 SCSI bus 0

CA_084 A OMU 0 1.0B 16.5H A WDU 1 (OMU) 2.0B 14.2P CHS012 SCSI bus 1

CA_085 A OMU 0 1.0B 16.5O A WDU 1 (OMU) 2.0B 14.2V CHS012 SCSI bus 1

CA_086 A OMU 0 1.0B 16.5U A WDU 1 (OMU) 2.0B 14.3B CHS012 SCSI bus 1

CA_087 A OMU 1 2.0B 16.5H A WDU 1 (OMU) 2.0B 14.3H CHS006 SCSI bus 1

CA_088 A OMU 1 2.0B 16.5O A WDU 1 (OMU) 2.0B 14.3O CHS006 SCSI bus 1

CA_089 A OMU 1 2.0B 16.5U A WDU 1 (OMU) 2.0B 14.3U CHS006 SCSI bus 1

CA_090 A OMS 1.0B 6.5H A HDD 1 (OMS) 2.0B 14.4P CHS012 SCSI bus 1

CA_091 A OMS 1.0B 6.5O A HDD 1 (OMS) 2.0B 14.4V CHS012 SCSI bus 1

CA_092 A OMS 1.0B 6.5U A HDD 1 (OMS) 2.0B 14.5B CHS012 SCSI bus 1

Page 15: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 15/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 15 (42)

Table 5 RNAC HMS bus cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_040 A OMU 0 1.0B 16.3F A TBU 0 1.0B 19.2A CHZ006 HMS bus 0

CA_041 A OMU 1 2.0B 16.3F A TBU 0 2.0B 19.2A CHZ006 HMS bus 0

CA_042 A TBU 0 1.0B 19.2B A TBU 0 2.0B 19.2B CHZ011 HMS bus 0

CA_043 A TBU 0 2.0B 19.2C A TBU 0 3.0B 19.2A CHZ012 HMS bus 0

CA_044 A TBU 0 3.0B 19.2B A TBU 0 4.0B 19.2A CHZ012 HMS bus 0

CA_046 A TBU 0 4.0B 19.2C A TBU 0 4.0B 19.2D CHZ001   HMS bus 0term.

CA_047 A OMU 0 1.0B 16.3G A TBU 1 1.0B 38.5A CHZ005 HMS bus 1

CA_048 A OMU 1 2.0B 16.3G A TBU 1 2.0B 38.5A CHZ005 HMS bus 1

CA_049 A TBU 1 1.0B 38.5B A TBU 1 2.0B 38.5B CHZ009 HMS bus 1

CA_050 A TBU 1 2.0B 38.5C A TBU 1 3.0B 38.5A CHZ010 HMS bus 1

CA_051 A TBU 1 3.0B 38.5B A TBU 1 4.0B 38.5A CHZ010 HMS bus 1

CA_053 A TBU 1 4.0B 38.5C A TBU 1 4.0B 38.5D CHZ001   HMS bus1term.

CA_054 A TBU 0 1.0B 19.1Z A TBU 1 2.0B 38.4Z CHZS010 HMS bus

Note: For information on terminating cables, see Table 19 Intercabinet HMS and timing cables from RNBC to RNAC.

Table 6 RNAC timing bus cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_063 A TBU 0 1.0B 19.2M A TBU 0 2.0B 19.2K CHZ011 TIMING bus 0

CA_064 A TBU 0 2.0B 19.2L A TBU 0 3.0B 19.2K CHZ012 TIMING bus 0

CA_065 A TBU 0 3.0B 19.2L A TBU 0 4.0B 19.2K CHZ012 TIMING bus 0

CA_066 A TBU 0 4.0B 19.2L A TBU 0 4.0B 19.2E CHZ001   TIMING bus 0term.

CA_070 A TBU 1 2.0B 38.5M A TBU 1 1.0B 38.5K CHZ009 TIMING bus 1

CA_071 A TBU 1 1.0B 38.5L A TBU 1 3.0B 38.5K CHZ015 TIMING bus 1

CA_072 A TBU 1 3.0B 38.5L A TBU 1 4.0B 38.5K CHZ010 TIMING bus 1

CA_073 A TBU 1 4.0B 38.5L A TBU 1 4.0B 38.5E CHZ001   TIMING bus 1term.

Page 16: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 16/42

Cable Lists for RNC2600

16 (42) © Nokia Siemens Networks DN70539915Issue 2-0

Table 7 RNAC default line timing cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_060 A NPS1/NPS1P 2 3.0B 16.4V A TBU 0 1.0B 19.2G CHZ028 TIMING ref. 1   1) Default linetiming

CA_061 A NPS1/NPS1P 3 4.0B 16.4V A TBU 0 1.0B 19.2H CHZ028 TIMING ref. 2   1) Default linetiming

CA_062 A NPS1/NPS1P 4 3.0B 18.4V A T BU 0 1.0B 19.2J CHZ028 TIMING ref. 3   1) Default linetiming

CA_067 A NPS1/NPS1P 2 3.0B 16.4X A TBU 1 2.0B 38.5G CHZ028 TIMING ref. 1   1) Default linetiming

CA_068 A NPS1/NPS1P 3 4.0B 16.4X A TBU 1 2.0B 38.5H CHZ028 TIMING ref. 2   1) Default linetiming

CA_069 A NPS1/NPS1P 4 3.0B 18.4X A T BU 1 2.0B 38.5J CHZ028 TIMING ref. 3   1) Default line

timing1) These cables must be installed last. They are bundled separately from other cables for easier modification.

Page 17: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 17/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 17 (42)

Figure 4 Routing of line timing cables CA_060 – CA_062 and CA_067 –CA_069

Page 18: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 18/42

Cable Lists for RNC2600

18 (42) © Nokia Siemens Networks DN70539915Issue 2-0

3.3 RNAC LVDS cables

3.3.1 RNAC synchronization and LVDS cables

Table 8 RNAC SFU LVDS cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_200 A   SFU 0 /

BISFD

1.0B 1.B00 A   MXU 0 /

BISFB

1.0B 9.B00 CSB007 LVDS lines 3)

CA_201 A   SFU 0 /BISFD

1.0B 1.B01 A   MXU 1 /BISFB

1.0B 11.B00 CSB009 LVDS lines 3)

CA_202 A   SFU 0 /BISFD

1.0B 1.B02 A   MXU 2 /BISFB

2.0B 9.B00 CSB012 LVDS lines 3)

CA_203 A   SFU 0 /BISFD

1.0B 1.B03 A   MXU 3 /BISFB

2.0B 11.B00 CSB013 LVDS lines 3)

CA_204 A   SFU 0 /BISFD

1.0B 1.B04 A   MXU 4 /BISFB

3.0B 9.B00 CSB017 LVDS lines 3)

CA_205 A   SFU 0 /BISFD

1.0B 1.B05 A   MXU 5 /BISFB

3.0B 11.B00 CSB018 LVDS lines 3)

CA_206 A   SFU 0 /BISFD

1.0B 1.B06 A   MXU 6 /BISFB

4.0B 9.B00 CSB022 LVDS lines 3)

CA_207 A   SFU 0 /

BISFD

1.0B 1.B07 A   MXU 7 /

BISFB

4.0B 11.B00 CSB023 LVDS lines 3)

CA_210 A   SFU 0 /BISFA

1.0B 2.B16 A   NPGE/NPGEP 0 /NP1S/NPS1P 0

BISFC

1.0B 17.B00 CSB009 LVDS lines 3)

CA_211 A   SFU 0 /BISFA

1.0B 2.B17 A   NPGE/NPGEP 1 /NP1S/NPS1P 1BISFC

2.0B 17.B00 CSB014 LVDS lines 3)

CA_216 A   SFU 0 /BISFA

1.0B 2.B18 A NPGE/NPGEP 2

BISFC

1.0B 18. B00 CSB009 LVDS lines   1) 3) Default:connected

CA_217 A   SFU 0 /BISFA

1.0B 2.B19 A NPGE/NPGEP 3

BISFC

2.0B 18. B00 CSB014 LVDS lines   2) 3) Default:connected

CA_212 A   SFU 0 /BISFA

1.0B 2.B20 A   NPGE/NPGEP 4 /NP1S/NPS1P 2

BISFC

3.0B 15.B00 CSB019 LVDS lines 3)

CA_213 A   SFU 0 /BISFA

1.0B 2.B21 A   NPGE/NPGEP 5 /NP1S/NPS1P 3BISFC

4.0B 15.B00 CSB025 LVDS lines 3)

CA_214 A   SFU 0 /BISFA

1.0B 2.B22 A   NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC

3.0B 17.B00 CSB019 LVDS lines 3)

CA_215 A   SFU 0 /BISFA

1.0B 2.B23 A   NPGE/NPGEP 7 /NP1S/NPS1P 5BISFC

4.0B 17.B00 CSB025 LVDS lines 3)

Page 19: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 19/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 19 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CA_220 A   SFU 1 /BISFD

2.0B 1. B00 A   MXU 0 /BISFB

1.0B 9.B02 CSB012 LVDS lines 3)

CA_221 A   SFU 1 /BISFD

2.0B 1. B01 A   MXU 1 /BISFB

1.0B 11.B02 CSB013 LVDS lines 3)

CA_222 A   SFU 1 /BISFD

2.0B 1. B02 A   MXU 2 /BISFB

2.0B 9.B02 CSB007 LVDS lines 3)

CA_223 A   SFU 1 /BISFD

2.0B 1. B03 A   MXU 3 /BISFB

2.0B 11.B02 CSB008 LVDS lines 3)

CA_224 A   SFU 1 /BISFD

2.0B 1. B04 A   MXU 4 /BISFB

3.0B 9.B02 CSB012 LVDS lines 3)

CA_225 A   SFU 1 /BISFD

2.0B 1. B05 A   MXU 5 /BISFB

3.0B 11.B02 CSB013 LVDS lines 3)

CA_226 A   SFU 1 /

BISFD

2.0B 1. B06 A   MXU 6 /

BISFB

4.0B 9.B02 CSB017 LVDS lines 3)

CA_227 A   SFU 1 /BISFD

2.0B 1. B07 A   MXU 7 /BISFB

4.0B 11.B02 CSB018 LVDS lines 3)

CA_230 A   SFU 1 /BISFA

2.0B 2. B16 A   NPGE/NPGEP 0 /NP1S/NPS1P 0 /BISFC

1.0B 17.B02 CSB014 LVDS lines 3)

CA_231 A   SFU 1 /BISFA

2.0B 2. B17 A   NPGE/NPGEP 1 /NP1S/NPS1P 1BISFC

2.0B 17.B02 CSB008 LVDS lines 3)

CA_236 A   SFU 1 /BISFA

2.0B 2.B18 A NPGE/NPGEP 2

BISFC

1.0B 18.B02 CSB015 LVDS lines   1) 3) Default:connected

CA_237 A   SFU 1 /BISFA

2.0B 2.B19 A NPGE/NPGEP 3

BISFC

2.0B 18.B02 CSB008 LVDS lines   2) 3) Default:connected

CA_232 A   SFU 1 /BISFA

2.0B 2. B20 A   NPGE/NPGEP 4 /NP1S/NPS1P 2BISFC

3.0B 15.B02 CSB014 LVDS lines 3)

CA_233 A   SFU 1 /BISFA

2.0B 2. B21 A   NPGE/NPGEP 5 /NP1S/NPS1P 3BISFC

4.0B 15.B02 CSB019 LVDS lines 3)

CA_234 A   SFU 1 /BISFA

2.0B 2. B22 A   NPGE/NPGEP 6 /NP1S/NPS1P 4 /BISFC

3.0B 17.B02 CSB014 LVDS lines 3)

CA_235 A   SFU 1 /BISFA

2.0B 2. B23 A   NPGE/NPGEP 7 /NP1S/NPS1P 5BISFC

4.0B 17.B02 CSB019 LVDS lines 3)

1) Default: Connected when NPGE/NPGEP 2 is in configuration.

Optional: Removed when NPS1/NPS1P 0 is in configuration.

2) Default: Connected when NPGE/NPGEP 3 is in configuration.

Optional: Removed when NPS1/NPS1P 1 is in configuration.

3) Cables are connected after the BISFA, BISFB, BISFC and BISFD back interface units have been installed. Insert the back interface unitcarefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.

Page 20: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 20/42

Cable Lists for RNC2600

20 (42) © Nokia Siemens Networks DN70539915Issue 2-0

Table 9 TSS3 synchronization cable

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_305 A TSS3 1.0B 19.1X A TSS3 2.0B 38.4X CHE011 Sync

3.4 RNAC LAN cables

Table 10 RNAC SWU (ESA24) LAN cables with one SWU pair (SWU0/1)

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_132 A SWU 0 1.0B 5.4G A OMS 1.0B 6.3B CHES006 LAN

CA_131 A SWU 0 1.0B 5.4E A OMU 1 2.0B 16.3B CHES013 LAN

CA_130 A SWU 0 1.0B 5.4C A OMU 0 1.0B 16.3B CHES006 LAN

CA_145 A SWU 0 1.0B 5.5D A NPGE/NPGEP 7 /

NPS1/NPS1P 5BISFC

4.0B 17.4E CIBS027 LAN

CA_144 A SWU 0 1.0B 5.5B A NPGE/NPGEP 6 /

NPS1/NPS1P 4BISFC

3.0B 17.4E CIBS021 LAN

CA_143 A SWU 0 1.0B 5.4Z A NPGE/NPGEP 5 /

NPS1/NPS1P 3BISFC

4.0B 15.4E CIBS027 LAN

CA_172 A SWU 0 1.0B 5.4X A NPGE/NPGEP 4 /

NPS1/NPS1P 2BISFC

3.0B 15.4E CIBS021 LAN

CA_147 A SWU 0 1.0B 5.4V A   NPGE/NPGEP 3BISFC

2.0B 18.4E CIBS013 LAN   2) Default:connected

CA_146 A SWU 0 1.0B 5.4T A   NPGE/NPGEP 2BISFC

1.0B 18.4E CIBS007 LAN   1) Default:connected

CA_171 A SWU 0 1.0B 5.4R A NPGE/NPGEP 1 /

NPS1/NPS1P 1BISFC

2.0B 17.4E CIBS013 LAN

CA_140 A SWU 0 1.0B 5.4P A NPGE/NPGEP 0 /

NPS1/NPS1P 0

BISFC

1.0B 17.4E CIBS007 LAN

Page 21: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 21/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 21 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CA_134 A SWU 1 2.0B 5.4J A SWU 0 1.0B 5.4J CHES017 LAN   3) Default:Notconnected

CA_133 A SWU 1 2.0B 5.4G A OMS 1.0B 6.3D CHES016 LAN

CA_139 A SWU 1 2.0B 5.4E A OMU 1 2.0B 16.3D CHES007 LAN

CA_138 A SWU 1 2.0B 5.4C A OMU 0 1.0B 16.3D CHES014 LAN

CA_155 A SWU 1 2.0B 5.5D A NPGE/NPGEP 7 /

NPS1/NPS1P 5BISFC

4.0B 17.4G CIBS021 LAN

CA_154 A SWU 1 2.0B 5.5B A NPGE/NPGEP 6 /

NPS1/NPS1P 4BISFC

3.0B 17.4G CIBS021 LAN

CA_153 A SWU 1 2.0B 5.4Z A NPGE/NPGEP 5 /

NPS1/NPS1P 3BISFC

4.0B 15.4G CIBS021 LAN

CA_152 A SWU 1 2.0B 5.4X A NPGE/NPGEP 4 /

NPS1/NPS1P 2BISFC

3.0B 15.4G CIBS014 LAN

CA_149 A SWU 1 2.0B 5.4V A   NPGE/NPGEP 3BISFC

2.0B 18.4G CIBS007 LAN   2) Default:connected

CA_148 A SWU 1 2.0B 5.4T A   NPGE/NPGEP 2BISFC

1.0B 18.4G CIBS013 LAN   1) Default:connected

CA_151 A SWU 1 2.0B 5.4R A NPGE/NPGEP 1 /

NPS1/NPS1P 1BISFC

2.0B 17.4G CIBS007 LAN

CA_150 A SWU 1 2.0B 5.4P A NPGE/NPGEP 0 /

NPS1/NPS1P 0BISFC

1.0B 17.4G CIBS013 LAN

1) Default: Connected at factory. Connected when NPGE/NPGEP 2 is in configuration.Optional: Removed when NPS1/NPS1P 0 is in configuration.

2) Default: Connected at factory. Connected when NPGE/NPGEP 3 is in configuration.Optional: Removed when NPS1/NPS1P 1 is in configuration.

3) Default: Redundancy cable is not connected at the factory.Optional: The cable is connected only when the Rabid Spanning Tree Protocol (RSTP) is enabled in the LAN sub network. Before

connecting the cable, activate STP/RSTP/MSTP according to the planned resiliency method.

Page 22: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 22/42

Cable Lists for RNC2600

22 (42) © Nokia Siemens Networks DN70539915Issue 2-0

Table 11 Address setting modules

Position ID Name Use Note

1.0B 5.1S C108585 ADMOD01 SW U Cabinet address setting module1.0B 5.1U C108585 ADMOD01 SW U Subrack address setting module

2.0B 5.1S C108585 ADMOD01 SW U Cabinet address setting module

2.0B 5.1U C108690 ADMOD02 SW U Subrack address setting module

3.5 RNAC alarm and synchronization cables

Table 12 RNAC alarm and synchronization cables to rear panels CPSY- A, CPSY-B and CPAL-A

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_300 A CPAL-A 2.0B 1.A A EHU 3.0B 5.4G CJA016 ALARM

CA_301 A CPAL-A 2.0B 1.G A EHU 3.0B 5.4P CHQ016 ALARM

CA_302 A CPAL-A 2.0B 1.P A EHU 3.0B 5.4X CHM016 ALARM

CA_015 A CAIND 0.0B 1 A EHU 3.0B 5.4E CID030 ALARM

1.0B 1.C 1) Default1.0B 1.G 2) Optional

1.0B 1.L 3) Optional

CA_303 A CPSY-A

1.0B 1.P

 A TSS3 1.0B 19.1V CHE010 SYNC

4) Optional

1.10B 1.A 1) Default

1.10B 1.E 2) Optional

1.10B 1.J 3) Optional

CA_304 A CPSY-B

1.10B 1.N

 A TSS3 2.0B 38.4V CHE010 SYNC

4) Optional

CA_298 A SWU 0 1.0B 5.5Y A CPSY-A 1.0B 1.1V CHE012 ETHERNET

CA_299 A CPSY-A 1.0B 1.1R A CPSY-B 1.10B 1.1T CHE005 SYNC

CA_297 A CPSY-A 1.0B 1.1T A CPSY-B 1.10B 1.1R CHE005 SYNC

1) BNC IN, BNC OUT, Default2) BNC IN, RJ 45 OUT, Optional3) RJ 45 IN, BNC OUT, Optional4) RJ 45 IN, RJ 45 OUT, Optional

Page 23: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 23/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 23 (42)

1 9 18 1 7 1 6 15 1 4 1 3 12 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 18 1 7 1 6 15 1 4 1 3 12 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 18 1 7 1 6 15 1 4 1 3 12 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 18 1 7 1 6 15 1 4 1 3 12 1 1 1 0 9 8 7 6 5 4 3 2 1

38

CPSY-A

CPAL-A

CPSY-B

DN05160803

Figure 5 CPSY-A, CPSY-B and CPAL-A panel positions in RNAC

Page 24: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 24/42

Cable Lists for RNC2600

24 (42) © Nokia Siemens Networks DN70539915Issue 2-0

3.6 RNAC protection switch cables

Table 13 MSP1+1, PIU_OK, PAIR_OK and switchover cables for RNAC

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CA_370 A NPS1P 0 1.0B 18.4T A NPS1P 1 2.0B 18.4T CIBS010   MSP1+1ProtectionSwitch

1) Default:notconnected

CA_375 A NPS1P 0 1.0B 18.4R A NPS1P 1 2.0B 18.4R CIBS010   LVDS linesProtectionSwitch

1) Default:notconnected

CA_374 A NPS1P 0 1.0B 18.4P A NPS1P 1 2.0B 18.4P CIBS010   LVDS linesProtectionSwitch

1) Default:notconnected

CA_165 A NPGEP 2 1.0B 18.4L A NPGEP 3 2.0B 18.4L CHZS010 Switchover  

NPS1P 0 NPS1P 1   MSP1+1ProtectionSwitch

CA_373 A

NPGEP 2

1.0B 18.4J A

NPGEP 3

2.0B 18.4J CIBS010

PIU_OK/PAIR_OK

CA_372 A NPS1P 0 1.0B 18.4G A NPS1P 1 2.0B 18.4G CIBS010   MSP1+1ProtectionSwitch

1) Default:notconnected

CA_371 A NPS1P 0 1.0B 18.4E A NPS1P 1 2.0B 18.4E CIBS010   MSP1+1ProtectionSwitch

1) Default:notconnected

CA_163 A NPGEP 0 /

NPS1P 0

1.0B 17. 4L A NPGEP 1 /

NPS1P 1

2.0B 17.4L CHZS010 Switchover 

CA_164 A NPGEP 0 /

NPS1P 0

1.0B 17.4K A NPGEP 1 /

NPS1P 1

2.0B 17.4K CHZS010   PIU_OK/PAIR_OK

1) Default: Not connected at the factory. The cable is tied to the SRB1-C side plate near these equipping positions. Optional: Cables areconnected to these equipping positions when NPS1P 0 and NPS1P 1 pair are equipped.

CA_358 A NPS1P 2 3.0B 16.4T A NPS1P 3 4.0B 16.4T CIBS010   MSP1+1ProtectionSwitch

CA_361 A NPS1P 2 3.0B 16.4R A NPS1P 3 4.0B 16.4R CIBS010   LVDS linesProtectionSwitch

CA_360 A NPS1P 2 3.0B 16.4P A NPS1P 3 4.0B 16.4P CIBS010   LVDS linesProtectionSwitch

CA_351 A NPS1P 2 3.0B 16.4J A NPS1P 3 4.0B 16.4J CIBS010   MSP1+1ProtectionSwitch

CA_359 A NPS1P 2 3.0B 16.4G A NPS1P 3 4.0B 16.4G CIBS010   MSP1+1ProtectionSwitch

CA_350 A NPS1P 2 3.0B 16.4E A NPS1P 3 4.0B 16.4E CIBS010   MSP1+1ProtectionSwitch

Page 25: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 25/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 25 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CA_161 A NPGEP 4 /

NPS1P 2

3.0B 15.4L A NPGEP 5 /

NPS1P 3

4.0B 15.4L CHZS010 Switchover 

CA_162 A NPGEP 4 /

NPS1P 2

3.0B 15.4K A NPGEP 5 /

NPS1P 3

4.0B 15.4K CHZS010   PIU_OK/PAIR_OK

CA_354 A NPS1P 4 3.0B 18.4T A NPS1P 5 4.0B 18.4T CIBS010   MSP1+1ProtectionSwitch

CA_357 A NPS1P 4 3.0B 18.4R A NPS1P 5 4.0B 18.4R CIBS010   LVDS linesProtectionSwitch

CA_356 A NPS1P 4 3.0B 18.4P A NPS1P 5 4.0B 18.4P CIBS010   LVDS linesProtectionSwitch

CA_353 A NPS1P 4 3.0B 18.4J A NPS1P 5 4.0B 18.4J CIBS010   MSP1+1ProtectionSwitch

CA_355 A NPS1P 4 3.0B 18.4G A NPS1P 5 4.0B 18.4G CIBS010   MSP1+1ProtectionSwitch

CA_352 A NPS1P 4 3.0B 18.4E A NPS1P 5 4.0B 18.4E CIBS010   MSP1+1ProtectionSwitch

CA_156 A NPGEP 6 /

NPS1P 4

3.0B 17.4L A NPGEP 7 /

NPS1P 5

4.0B 17.4L CHZS010 Switchover 

CA_157 A NPGEP 6 /

NPS1P 4

3.0B 17.4K A NPGEP 7 /

NPS1P 5

4.0B 17.4K CHZS010   PIU_OK/PAIR_OK

Page 26: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 26/42

Cable Lists for RNC2600

26 (42) © Nokia Siemens Networks DN70539915Issue 2-0

4   Intracabinet cables for the RNBCcabinet

This chapter presents the intracabinet cabling for the RNBC cabinet inRNC2600.

Tip

The lengths of intracabinet cables in deliveries may be different thanthose given in this document.

4.1 RNBC power cables

Table 14 RNBC CPD120-A power cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB_001 B CPD120 UB2 0.10B P1 B PD30 0 1.0B 10_PP2 CVXB004 POWER

CB_002 B CPD120 UB1 0.0B P1 B PD30 0 1.0B 10_PP1 CVXB004 POWER

CB_003 B CPD120 UB2 0.10B P2 B PD30 1 2.0B 10_PP2 CVXB015 POWER

CB_004 B CPD120 UB1 0.0B P2 B PD30 1 2.0B 10_PP1 CVXB015 POWER

CB_005 B CPD120 UB2 0.10B P3 B PD30 2 3.0B 10_PP2 CVXB020 POWER

CB_006 B CPD120 UB1 0.0B P3 B PD30 2 3.0B 10_PP1 CVXB020 POWER

CB_007 B CPD120 UB2 0.10B P4 B PD30 3 4.0B 10_PP2 CVXB027 POWER

CB_008 B CPD120 UB1 0.0B P4 B PD30 3 4.0B 10_PP1 CVXB027 POWER

Page 27: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 27/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 27 (42)

4.2 RNBC control and bus cables

Table 15 RNBC control cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB_010 B FTRA 1 1.0B B PD30 0 1.0B 10_P1 CXVB18C CONTROL

CB_011 B FTRA 2 2.0B B PD30 1 2.0B 10_P1 CXVB18C CONTROL

CB_012 B FTRA 3 3.0B B PD30 2 3.0B 10_P1 CXVB18C CONTROL

CB_013 B FTRA 4 4.0B B PD30 3 4.0B 10_P1 CXVB18C CONTROL

Table 16 RNBC HMS bus cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB_020 B TBU 0 1.0B 19.2B B TBU 0 2.0B 19.2A CHZ011 HMS bus 0

CB_021 B TBU 0 2.0B 19.2B B TBU 0 3.0B 19.2A CHZ011 HMS bus 0

CB_022 B TBU 0 3.0B 19.2B B TBU 0 4.0B 19.2A CHZ011 HMS bus 0

CB_023 B TBU 0 4.0B 19.2C B TBU 0 4.0B 19.2D CHZ001 HMS bus 0term

CB_024 B TBU 1 1.0B 38.5B B TBU 1 2.0B 38.5A CHZ009 HMS bus 1

CB_025 B TBU 1 2.0B 38.5B B TBU 1 3.0B 38.5A CHZ009 HMS bus 1

CB_026 B TBU 1 3.0B 38.5B B TBU 1 4.0B 38.5A CHZ009 HMS bus 1

CB_027 B TBU 1 4.0B 38.5C B TBU 1 4.0B 38.5D CHZ001 HMS bus 1term

Table 17 RNBC timing bus cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB_030 B TBU 0 1.0B 19.2L B TBU 0 2.0B 19.2K CHZ011 TIMING bus 0

CB_031 B TBU 0 2.0B 19.2L B TBU 0 3.0B 19.2K CHZ011 TIMING bus 0

Page 28: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 28/42

Cable Lists for RNC2600

28 (42) © Nokia Siemens Networks DN70539915Issue 2-0

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB_032 B TBU 0 3.0B 19.2L B TBU 0 4.0B 19.2K CHZ011 TIMING bus 0

CB_033 B TBU 0 4.0B 19.2L B TBU 0 4.0B 19.2E CHZ001 TIMING bus 0term

CB_034 B TBU 1 1.0B 38.5L B TBU 1 2.0B 38.5K CHZ009 TIMING bus 1

CB_035 B TBU 1 2.0B 38.5L B TBU 1 3.0B 38.5K CHZ009 TIMING bus 1

CB_036 B TBU 1 3.0B 38.5L B TBU 1 4.0B 38.5K CHZ009 TIMING bus 1

CB_037 B TBU 1 4.0B 38.5L B TBU 1 4.0B 38.5E CHZ001 TIMING bus 1term

4.3 RNBC protection switch cables

Table 18 RNBC protection switch cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB_354 B NPS1P 6 1.0B 16.4T B NPS1P 7 2.0B 16.4T CIBS013 MSP1+1ProtectionSwitch

CB_371 B NPS1P 6 1.0B 16.4E B NPS1P 7 2.0B 16.4E CIBS013 LVDS linesProtectionSwitch

CB_370 B NPS1P 6 1.0B 16.4J B NPS1P 7 2.0B 16.4J CIBS013 LVDS linesProtectionSwitch

CB_357 B NPS1P 6 1.0B 16.4R B NPS1P 7 2.0B 16.4R CIBS013 MSP1+1ProtectionSwitch

CB_356 B NPS1P 6 1.0B 16.4P B NPS1P 7 2.0B 16.4P CIBS013 MSP1+1ProtectionSwitch

CB_355 B NPS1P 6 1.0B 16.4G B NPS1P 7 2.0B 16.4G CIBS013 MSP1+1ProtectionSwitch

CB_358 B NPS1P 8 1.0B 18.4T B NPS1P 9 2.0B 18.4T CIBS013 MSP1+1ProtectionSwitch

Page 29: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 29/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 29 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB_373 B NPS1P 8 1.0B 18.4E B NPS1P 9 2.0B 18.4E CIBS013 LVDS linesProtectionSwitch

CB_372 B NPS1P 8 1.0B 18.4J B NPS1P 9 2.0B 18.4J CIBS013 LVDS linesProtectionSwitch

CB_361 B NPS1P 8 1.0B 18.4R B NPS1P 9 2.0B 18.4R CIBS013 MSP1+1ProtectionSwitch

CB_360 B NPS1P 8 1.0B 18.4P B NPS1P 9 2.0B 18.4P CIBS013 MSP1+1ProtectionSwitch

CB_359 B NPS1P 8 1.0B 18.4G B NPS1P 9 2.0B 18.4G CIBS013 MSP1+1ProtectionSwitch

CB_362 B NPS1P 10 3.0B 16.4T B NPS1P 11 4.0B 16.4T CIBS013 MSP1+1ProtectionSwitch

CB_375 B NPS1P 10 3.0B 16.4E B NPS1P 11 4.0B 16.4E CIBS013 LVDS linesProtectionSwitch

CB_374 B NPS1P 10 3.0B 16.4J B NPS1P 11 4.0B 16.4J CIBS013 LVDS linesProtectionSwitch

CB_365 B NPS1P 10 3.0B 16.4R B NPS1P 11 4.0B 16.4R CIBS013 MSP1+1ProtectionSwitch

CB_364 B NPS1P 10 3.0B 16.4P B NPS1P 11 4.0B 16.4P CIBS013 MSP1+1ProtectionSwitch

CB_363 B NPS1P 10 3.0B 16.4G B NPS1P 11 4.0B 16.4G CIBS013 MSP1+1ProtectionSwitch

CB_366 B NPS1P 12 3.0B 18.4T B NPS1P 13 4.0B 18.4T CIBS013 MSP1+1ProtectionSwitch

CB_377 B NPS1P 12 3.0B 18.4E B NPS1P 13 4.0B 18.4E CIBS013 LVDS lines

ProtectionSwitch

CB_376 B NPS1P 12 3.0B 18.4J B NPS1P 13 4.0B 18.4J CIBS013 LVDS linesProtectionSwitch

CB_369 B NPS1P 12 3.0B 18.4R B NPS1P 13 4.0B 18.4R CIBS013 MSP1+1ProtectionSwitch

CB_368 B NPS1P 12 3.0B 18.4P B NPS1P 13 4.0B 18.4P CIBS013 MSP1+1ProtectionSwitch

Page 30: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 30/42

Cable Lists for RNC2600

30 (42) © Nokia Siemens Networks DN70539915Issue 2-0

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB_367 B NPS1P 12 3.0B 18.4G B NPS1P 13 4.0B 18.4G CIBS013 MSP1+1ProtectionSwitch

CB_380 B NPGEP 8 /

NPS1P 6

1.0B 15.4K B NPGEP 9 /

NPS1P 7

2.0B 15.4K CHZS015 PIU_OK

PAIR_OK

CB_381 B NPGEP 10 /

NPS1P 8

1.0B 17.4K B NPGEP 11 /

NPS1P 9

2.0B 17.4K CHZS015 PIU_OK

PAIR_OK

CB_382 B NPGEP 12 /

NPS1P 10

3.0B 15.4K B NPGEP 13 /

NPS1P 11

4.0B 15.4K CHZS015 PIU_OK

PAIR_OK

CB_383 B NPGEP 14 /NPS1P 12

3.0B 17.4K B NPGEP 15 /NPS1P 13

4.0B 17.4K CHZS015 PIU_OKPAIR_OK

CB_390 B NPGEP 8 /

NPS1P 6

1.0B 15.4L B NPGEP 9 /

NPS1P 7

2.0B 15.4L CHZS015 Switchover 

CB_391 B NPGEP 10 /

NPS1P 8

1.0B 17.4L B NPGEP 11 /

NPS1P 9

2.0B 17.4L CHZS015 Switchover 

CB_392 B NPGEP 12 /

NPS1P 10

3.0B 15.4L B NPGEP 13 /

NPS1P 11

4.0B 15.4L CHZS015 Switchover 

CB_393 B NPGEP 14 /

NPS1P 12

3.0B 17.4L B NPGEP 15 /

NPS1P 13

4.0B 17.4L CHZS015 Switchover 

Page 31: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 31/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 31 (42)

5   Intercabinet cables from RNBC to RNAC

This chapter presents cabling from the RNBC cabinet to the RNACcabinet in RNC2600.

5.1 Intercabinet HMS and timing cables

Table 19 Intercabinet HMS and timing cables from RNBC to RNAC

CABLE FROM CABLE TO

Equip.No

      C     a

      b      i     n     e      t

FU Position

      C     a

      b      i     n     e      t

FU Position  Type Use Note

 A 3.0B 19.2E 1) Timing

bus 0 term.CB0_050

B

TBU 0

1.0B 19.2K

 A TBU 0 1.0B 19.2N CHZ020 TIMING bus 0

2) Timing

bus 0 to

B-cabinet

 A 3.0B 38.5E   1) Timing bus1 term.CB0_051

B

TBU 1

1.0B 38.5K

 A TBU 1 2.0B 38.5N CHZ020 TIMING bus 1

2) Timing

bus 1 to

B-cabinet

 A 3.0B 19.2D 1) HMS term.

CB0_040   B   TBU 0   1.0B 19.2A   A TBU 0 1.0B 19.2C CHZ020 HMS bus 0   2) HMS to

B-cabinet

 A 3.0B 38.5D 1) HMS term.

CB0_041   B   TBU 1   1.0B 38.5A   A TBU 1 1.0B 38.5C CHZ020 HMS bus 1   2) HMS to

B-cabinet

Page 32: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 32/42

Cable Lists for RNC2600

32 (42) © Nokia Siemens Networks DN70539915Issue 2-0

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

1) Default: Connected at factory. Connect the terminating cables to subrack 3 if RNBC cabinet is not in the configuration.

2) Optional: If RNBC cabinet is in the configuration, these cables are moved to RNBC subrack 1.

Note that if there is no RNBC cabinet in the configuration, all of these cables are in the RNAC cabinet.

Page 33: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 33/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 33 (42)

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

RNBC RNAC

DN05160893

= HMS bus 0 / Timing bus 0= HMS bus 1 / Timing bus 1

Figure 6 Routing of HMS cables CB0_040 – CB0_041 and timing cablesCB0_050 – CB0_051

Page 34: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 34/42

Cable Lists for RNC2600

34 (42) © Nokia Siemens Networks DN70539915Issue 2-0

5.2 Intercabinet SWU LAN cables

Table 20 Intercabinet SWU LAN cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB0_107 B NPGE/NPGEP 15 /

NPS1/NPS1P 13BISFC

4.0B 17.4E A SWU 0 1.0B 5.5U CIBS027 LAN 1)

CB0_106 B NPGE/NPGEP 14 /

NPS1/NPS1P 12BISFC

3.0B 17.4E A SWU 0 1.0B 5.5S CIBS021 LAN 1)

CB0_105 B NPGE/NPGEP 13 /

NPS1/NPS1P 11BISFC

4.0B 15.4E A SWU 0 1.0B 5.5Q CIBS027 LAN 1)

CB0_104 B NPGE/NPGEP 12 /

NPS1/NPS1P 10BISFC

3.0B 15.4E A SWU 0 1.0B 5.5O CIBS021 LAN 1)

CB0_103 B NPGE/NPGEP 11 /

NPS1/NPS1P 9BISFC

2.0B 17.4E A SWU 0 1.0B 5.5M CIBS018 LAN 1)

CB0_102 B NPGE/NPGEP 10 /

NPS1/NPS1P 8BISFC

1.0B 17.4E A SWU 0 1.0B 5.5K CIBS014 LAN 1)

CB0_101 B NPGE/NPGEP 9 /

NPS1/NPS1P 7BISFC

2.0B 15.4E A SWU 0 1.0B 5.5H CIBS018 LAN 1)

CB0_100 B NPGE/NPGEP 8 /

NPS1/NPS1P 6BISFC

1.0B 15.4E A SWU 0 1.0B 5.5F CIBS014 LAN 1)

CB0_115 B NPGE/NPGEP 15 /

NPS1/NPS1P 13BISFC

4.0B 17.4G A SWU 1 2.0B 5.5U CIBS021 LAN 1)

CB0_114 B NPGE/NPGEP 14 /

NPS1/NPS1P 12BISFC

3.0B 17.4G A SWU 1 2.0B 5.5S CIBS018 LAN 1)

CB0_113 B NPGE/NPGEP 13 /

NPS1/NPS1P 11BISFC

4.0B 15.4G A SWU 1 2.0B 5.5Q CIBS021 LAN 1)

CB0_112 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

3.0B 15.4G A SWU 1 2.0B 5.5O CIBS018 LAN 1)

CB0_111 B NPGE/NPGEP 11 /

NPS1/NPS1P 9BISFC

2.0B 17.4G A SWU 1 2.0B 5.5M CIBS014 LAN 1)

CB0_110 B NPGE/NPGEP 10 /

NPS1/NPS1P 8BISFC

1.0B 17.4G A SWU 1 2.0B 5.5K CIBS018 LAN 1)

Page 35: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 35/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 35 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB0_109 B NPGE/NPGEP 9 /

NPS1/NPS1P 7BISFC

2.0B 15.4G A SWU 1 2.0B 5.5H CIBS014 LAN 1)

CB0_108 B NPGE/NPGEP 8 /

NPS1/NPS1P 6BISFC

1.0B 15.4G A SWU 1 2.0B 5.5F CIBS018 LAN 1)

1) Cables are connected before the BISFC back interface unit has been installed.

5.3 Intercabinet SFU LVDS lines

Table 21 Intercabinet SFU LVDS cables

CABLE FROM CABLE TO

Equip.No

      C     a      b      i     n     e      t

FU Position

      C     a      b      i     n     e      t

FU Position  Type Use Note

CB0_200 B MXU 8 /

BISFB

1.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B08 CSB018 LVDS lines 1)

CB0_201 B MXU 9 /

BISFB

1.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B09 CSB021 LVDS lines 1)

CB0_202 B MXU 10 /

BISFB

2.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B10 CSB022 LVDS lines 1)

CB0_203 B MXU 11 /

BISFB

2.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B11 CSB024 LVDS lines 1)

CB0_204 B MXU 12 /

BISFB

3.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B12 CSB028 LVDS lines 1)

CB0_205 B MXU13 /

BISFB

3.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B13 CSB030 LVDS lines 1)

CB0_206 B MXU 14 /

BISFB

4.0B 9.B00 A SFU 0 /

BISFA

1.0B 2.B14 CSB032 LVDS lines 1)

CB0_207 B MXU 15 /

BISFB

4.0B 11.B00 A SFU 0 /

BISFA

1.0B 2.B15 CSB032 LVDS lines 1)

CB0_208 B NPGE/NPGEP 8 /

NPS1/NPS1P 6

BISFC

1.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B24 CSB019 LVDS lines 1)

CB0_209 B NPGE/NPGEP 9 /

NPS1/NPS1P 7

BISFC

2.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B25 CSB025 LVDS lines 1)

Page 36: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 36/42

Cable Lists for RNC2600

36 (42) © Nokia Siemens Networks DN70539915Issue 2-0

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB0_210 B NPGE/NPGEP 10 /

NPS1/NPS1P 8

BISFC

1.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B26 CSB019 LVDS lines 1)

CB0_211 B NPGE/NPGEP 11 /

NPS1/NPS1P 9

BISFC

2.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B27 CSB025 LVDS lines 1)

CB0_212 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

BISFC

3.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B28 CSB031 LVDS lines 1)

CB0_213 B NPGE/NPGEP 13 /

NPS1/NPS1P 11

BISFC

4.0B 15.B00 A SFU 0 /

BISFA

1.0B 2.B29 CSB034 LVDS lines 1)

CB0_214 B NPGE/NPGEP 14 /NPS1/NPS1P 12

BISFC

3.0B 17.B00 A SFU 0 /BISFA

1.0B 2.B30 CSB031 LVDS lines 1)

CB0_215 B NPGE/NPGEP 15 /

NPS1/NPS1P 13

BISFC

4.0B 17.B00 A SFU 0 /

BISFA

1.0B 2.B31 CSB034 LVDS lines 1)

CB0_216 B MXU 8 /

BISFB

1.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B08 CSB022 LVDS lines 1)

CB0_217 B MXU 9 /

BISFB

1.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B09 CSB024 LVDS lines 1)

CB0_218 B MXU 10 /

BISFB

2.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B10 CSB018 LVDS lines 1)

CB0_219 B MXU 11 /BISFB

2.0B 11.B02 A SFU 1 /BISFA

2.0B 2.B11 CSB021 LVDS lines 1)

CB0_220 B MXU 12 /

BISFB

3.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B12 CSB022 LVDS lines 1)

CB0_221 B MXU 13 /

BISFB

3.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B13 CSB024 LVDS lines 1)

CB0_222 B MXU 14 /

BISFB

4.0B 9.B02 A SFU 1 /

BISFA

2.0B 2.B14 CSB028 LVDS lines 1)

CB0_223 B MXU 15 /

BISFB

4.0B 11.B02 A SFU 1 /

BISFA

2.0B 2.B15 CSB030 LVDS lines 1)

CB0_224 B NPGE/NPGEP 8 /

NPS1/NPS1P 6

BISFC

1.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B24 CSB025 LVDS lines 1)

CB0_225 B NPGE/NPGEP 9 /

NPS1/NPS1P 7

BISFC

2.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B25 CSB019 LVDS lines 1)

CB0_226 B NPGE/NPGEP 10 /

NPS1/NPS1P 8

BISFC

1.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B26 CSB025 LVDS lines 1)

CB0_227 B NPGE/NPGEP 11 /

NPS1/NPS1P 9

BISFC

2.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B27 CSB019 LVDS lines 1)

Page 37: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 37/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 37 (42)

CABLE FROM CABLE TO

Equip.No

      C

     a      b      i     n     e      t

FU Position

      C

     a      b      i     n     e      t

FU Position  Type Use Note

CB0_228 B NPGE/NPGEP 12 /

NPS1/NPS1P 10

BISFC

3.0B 15.B02 A SFU 1 /

BISFA

2.0B 2.B28 CSB025 LVDS lines 1)

CB0_229 B   NPGE/NPGEP 13 /NPS1/NPS1P 11BISFC

4.0B 15.B02 A   SFU 1 /BISFA

2.0B 2.B29 CSB031 LVDS lines 1)

CB0_230 B NPGE/NPGEP 14 /

NPS1/NPS1P 12

BISFC

3.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B30 CSB025 LVDS lines 1)

CB0_231 B NPGE/NPGEP 15 /

NPS1/NPS1P 13

BISFC

4.0B 17.B02 A SFU 1 /

BISFA

2.0B 2.B31 CSB031 LVDS lines 1)

1) Cables are connected after the BISFA, BISFB and BISFC back interface units have been installed. Insert the back interface unitcarefully. Check that the locking screws are closed properly, and that the back interface unit is in its place.

Page 38: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 38/42

Cable Lists for RNC2600

38 (42) © Nokia Siemens Networks DN70539915Issue 2-0

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

1 9 1 8 1 7 1 6 1 5 1 4 1 3 1 2 1 1 1 0 9 8 7 6 5 4 3 2 1

38

RNACRNBC

= LVDS lines / SFU 0

= LVDS lines / SFU 1

DN05160881

Figure 7 Routing of intercabinet LVDS cables CB0_001 – CB0_032

Page 39: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 39/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 39 (42)

6   Physical cable equipping positions andSW port connection coordinates

This section shows the physical cable equipping positions in the subrackand the corresponding SW port connection coordinates, used inhardware configuration management.

The cable connection coordinates are needed when creating internalport connections between plug-in units' ports. For more information, seeCreating connection descriptions  in  Hardware ConfigurationManagement .

For example, for a cable installed in position 1.0B 1.4A, the portconnection coordinate in hardware configuration management (WFcommands) is B76. See also Figure 8 Notations used in table Physical cable equipping positions and corresponding SW port connection

coordinates.

Page 40: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 40/42

Cable Lists for RNC2600

40 (42) © Nokia Siemens Networks DN70539915Issue 2-0

2A

C

E

G

J

L

N

P

R

T

X

Z

B

D

F

H

K

M

O

Q

S

U

3

B1B2

...

B25

B76

1

2

3

4

5

4A

...

...

B26

B51

B101

1 23

B76 4A

DN70206639

S H S H S H SW H SW HW

B1 1A B26 2A B51 3A B76 4A B101 5A

B2 1B B27 2B B52 3B B77 4B B102 5B

Slot position number 

Subrack seen from the rear 

1

2

3

4

5

12345678910111213141516171819

1

Figure 8 Notations used in table Physical cable equipping positions and corresponding SW port connection coordinates

Page 41: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 41/42

Cable Lists for RNC2600

DN70539915Issue 2-0

© Nokia Siemens Networks 41 (42)

Table 22 Physical cable equipping positions and corresponding SW portconnection coordinates

SW H SW HW SW HW SW HW SW HW

B1 1A B26 2A B51 3A B76 4A B101 5A

B2 1B B27 2B B52 3B B77 4B B102 5B

B3 1C B28 2C B53 3C B78 4C B103 5C

B4 1D B29 2D B54 3D B79 4D B104 5D

B5 1E B30 2E B55 3E B80 4E B105 5E

B6 1F B31 2F B56 3F B81 4F B106 5F

B7 1G B32 2G B57 3G B82 4G B107 5G

B8 1H B33 2H B58 3H B83 4H B108 5H

B9 1J B34 2J B59 3J B84 4J B109 5J

B10 1K B35 2K B60 3K B85 4K B110 5K

B11 1L B36 2L B61 3L B86 4L B111 5L

B12 1M B37 2M B62 3M B87 4M B112 5M

B13 1N B38 2N B63 3N B88 4N B113 5N

B14 1O B39 2O B64 3O B89 4O B114 5O

B15 1P B40 2P B65 3P B90 4P B115 5P

B16 1Q B41 2Q B66 3Q B91 4Q B116 5Q

B17 1R B42 2R B67 3R B92 4R B117 5R

B18 1S B43 2S B68 3S B93 4S B118 5S

B19 1T B44 2T B69 3T B94 4T B119 5T

B20 1U B45 2U B70 3U B95 4U B120 5U

B21 1V B46 2V B71 3V B96 4V B121 5V

B22 1W B47 2W B72 3W B97 4W B122 5W

B23 1X B48 2X B73 3X B98 4X B123 5X

B24 1Y B49 2Y B74 3Y B99 4Y B124 5Y

B25 1Z B50 2Z B75 3Z B100 4Z B125 5Z

Page 42: Cable Lists for RNC2600_RU20

8/9/2019 Cable Lists for RNC2600_RU20

http://slidepdf.com/reader/full/cable-lists-for-rnc2600ru20 42/42

Cable Lists for RNC2600