cable centriline celr 76426

Upload: melvin-castro

Post on 09-Jan-2016

68 views

Category:

Documents


0 download

DESCRIPTION

Cable ESP

TRANSCRIPT

Microsoft Word - 76426_2_5kv_DD13_LD_185_G_.375_G_R #2 Redondo con capilar.doc

CENTRILINE CELR with CAPILLARY ROUND SPECIFICATION

PART NUMBER:76426DESCRIPTION:2SOLBC 5KV DD13 LEAD 185 GALV 375 STNL TUBE GALV-R

1. CONDUCTOR:2AWG SOLID SOFT DRAWN BARE COPPER (SDBC)

DIA = .258"6.55 mm

2. INSULATION:EPDM DD13, 5KVDIA = .414 10.52 mmHIGH DIELECTRIC, OIL RESISTANT75 MIL NOMINAL THICKNESS68 MIL MINIMUM THICKNESS

3.LEAD SHEATH:LEAD, SPECIAL FATIGUE RESISTANTNOMINAL THICKNESS, 30MILDIA = .480 12.19 mm3A. BEDDING TAPE:Protection during cabling

4. JACKET:ENCAPSULATED EPDM FILLER JACKET, CL-185, OIL RESISTANT30 MIL NOMINAL THICKNESSNOMINAL DIAMETER OVER JACKET SPLINES=1.186 30.12 mm

5. INNER ARMOR:GALVANIZED STEEL ARMOR, 1/2" X .025"NOMINAL DIAMETER OVER ARMOR=1.336" 33.93 mm

6. TUBE:SPECIAL STAINLESS STEEL TUBE 3/8 x .049" WALL Internal working PSI = 4,900; burst PSI = 19,600

7. OUTER ARMOR:GALVANIZED STEEL ARMOR, 1/2" X .025" COATEDNOMINAL DIAMETER OVER ARMOR OVAL SHAPE =1.446 x 1.821"36.73 mm x 46.25 mmNOMINAL WEIGHT PER FOOT =3.26POUNDS4.85 kg/mMARKER:IDENTIFICATION TAPE PLACED PARALLEL UNDER ARMOR TEMPERATURE:TEMPERATURE RATING CENTRILINE =-40 C TO 260 C-400 F TO 5000 FTESTED:ICEA, IEEE 1018, AND CENTRILIFT SPECIFICATIONSMaterials and specifications are subject to change without notice.

126

54 3&3A7

Patented

76668CELR.doc, July 3, 2003, thw

This material contains Confidential Information of Baker Hughes, Inc. Unauthorized copying or dissemination of this Confidential Information is prohibited.