c10g-e067a shimadzu's total solutions for the hydrocarbon ... · gpa 2261, gpa 2177 gpa 2286,...
TRANSCRIPT
Shimadzu's Total Solutions for the H
ydrocarbon Processing Industry
C10G-E067A
www.shimadzu.com/an/
Analytical and Testing Instruments for the HPI Market
Shimadzu's Total Solutions for theHydrocarbon Processing Industry
© Shimadzu Corporation, 2019
For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “®”.Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
World Map of Shimadzu Sales, Service,Manufacturing, and R&D Facilities
Sales and Service
Manufacturing
R&D
Shimadzu's Total Solutionsfor the Hydrocarbon Processing Industry(Petrochemical, Chemical)
The Hydrocarbon Processing Industry (HPI), encompassing petroleum refining, gas
processing, petrochemical and chemical, is a foundational field for all industry. In the
HPI market, many kinds of analytical and measuring instruments are used for quality
control purposes and process management.
With a wide range of products, from GC and Elemental Analyzers to an On-line Water
Quality Analyzer, Shimadzu offers total support for laboratories in the HPI market.
From Upstream to Downstream, our rugged, high-quality products are perfectly suited
to meet the demands of your laboratory and contribute to your business success.
For more information about Shimadzu's solutions for the HPI market, visit our website at:https://www.shimadzu.com/an/industry/petrochemicalchemical/index.html
Developing, Extracting
Transporting, Storage
Exploration, Finding
Manufacturing, Refining
Supply, Trading
Upstream
Downstream
World Map of Shimadzu Sales, Service,Manufacturing, and R&D Facilities
Sales and Service
Manufacturing
R&D
Shimadzu's Total Solutionsfor the Hydrocarbon Processing Industry(Petrochemical, Chemical)
The Hydrocarbon Processing Industry (HPI), encompassing petroleum refining, gas
processing, petrochemical and chemical, is a foundational field for all industry. In the
HPI market, many kinds of analytical and measuring instruments are used for quality
control purposes and process management.
With a wide range of products, from GC and Elemental Analyzers to an On-line Water
Quality Analyzer, Shimadzu offers total support for laboratories in the HPI market.
From Upstream to Downstream, our rugged, high-quality products are perfectly suited
to meet the demands of your laboratory and contribute to your business success.
For more information about Shimadzu's solutions for the HPI market, visit our website at:https://www.shimadzu.com/an/industry/petrochemicalchemical/index.html
Developing, Extracting
Transporting, Storage
Exploration, Finding
Manufacturing, Refining
Supply, Trading
Upstream
Downstream
Shimadzu Customized GC Analyzers
Simulated Distillation AnalyzerTransformer Oil Gas Analyzer (TOGA)
Various Applications in the HPI Market
• Support third-party detectors, including a pulsed flame photometric detector (PFPD) and a pulsed discharge helium ionization detector (PDHID).
• Support third-party software for detailed hydrocarbon analysis (DHA) and Chrom Merge.
• Support liquefied petroleum gas (LPG) sampling devices and vaporizers.
• Complete application manual and methods
• Best-in-Class Sensitivity• Unmatched Stability performance • Excellent Maintainability• Automation Functions
Nexis GC-2030
Trace Sulfur Analysis GC System
• Comprehensive gasoline measurements determining bulk PIONA and specific oxygenate and BTEX compound content.
• Provides a lot of information in a fast, robust measurement.• Relatively simple instrumentation, setup, and analysis
procedures.
VUV PIONA+ Analysis GC System
Trace Moisture Analysis GC System
• Easily analyzes both liquid and gas samples
• Uses a variety of WatercolTM GC columns depending on the matrices
• Uses a simple, high-sensitivity, and very stable low-cost Barrier Ionization Discharge (BID) Detector
Analysis of Water in LPGNote: With baseline subtraction
uV BID
Water 25 ppm,
RT= 14.3 min, S/N=350+LPG(Main)
2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 min
0
2500
5000
7500
10000
12500
15000
Natural Gas Analyzers
ASTM D1945/D1946
GPA 2261, GPA 2177
GPA 2286, GPA 2186
ISO 6975Applicable Methods
Analysis
Features
C1-C6+ Hydrocarbons, Non Condensable gases O2, N2, CO, CO2 and H2S
Optional Hydrogen
Extended NGA C1-C14+
NGL, Dual Oven NGA
High Speed NGA
Analysis time 10 min.
UOP 539, ASTM D7833,
D 2163
C1-C6+ Hydrocarbons
saturates and unsaturates
H2S, Non Condensable gases O2, N2, CO, CO2 and H2
LPG Sampling
Vaporizer
Analysis time less than
6 min.
ASTM D1946
ASTM E1746
O2, N2, CO, CO2
Impurities in Chlorine
Special Hastelloy
Material for Chlorine Analyzer
ASTM D3612C
TOGA with Head Space
H2, O2, N2, CO, CO2, C1, C2's, C3's
High Sensitivity
Extension up to C4
ASTM
D6228
Trace Sulfur
PFPD for Sulfur
Refinery Gas Analyzer (RGA)
Process and Custom Gas Analyzers
Petrochemicals analyzer
TOGA/DGA Analyzer SimulatedDistillation
ASTM D7096, D7213, D3710, D2887, D6417, D6352, D7500, D5307, D7169, IP 480, ISO3924
Boiling Point Distribution
C1-C110 (As per method)
Fast Simdist
Correlations with D86 and D1160, Integrated Shimadzu Software
ASTM D5134, D6729, D6730, D6733, D8071
C1-C14 Hydrocarbons
PIONA Report
Tuned D6730 column
Fast DHA
Front End PIONA
Room Temperature
Database
VUV PIONA+
ASTM D4815,D7423
UOP 960
C1-C4 Alcohols
Use of N2 Carrier for D4815
ASTM D6228
ASTM D5504
ASTM D5623
ASTM D7011
Trace Sulfur Analysis Individual components
Use of FPD, PFPD or SCD Detectors
ASTM D3606, 5580
Aromatics
Combination model for D3606, D5580. D4815
DHA Analyzers Oxygenates Analyzers Aromatics AnalyzersSulfur Analyzers
Product Lineup
4Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 5
Rel
ativ
e R
esp
on
se F
acto
r
1.3
1.2
1.1
1.0
0.9
0.8
0.70 50 100 150 200 250 300 350 400
Analysis time (Hours) (Day 16)
1-Butanethiol b.p. 98℃Methyl disulfide b.p. 109℃Diethyl disulfide b.p. 152℃3-Methylbenzothiophene b.p. 273℃
Excellent Long-Term StabilityVUV Chromatogram of Gasoline Sample
* The VUV detector VGA-100 is a product of VUV ANALYTICS, INC.
Sulfur Chemiluminescence Detection Gas Chromatograph System
SCD-2030
Shimadzu Customized GC Analyzers
Simulated Distillation AnalyzerTransformer Oil Gas Analyzer (TOGA)
Various Applications in the HPI Market
• Support third-party detectors, including a pulsed flame photometric detector (PFPD) and a pulsed discharge helium ionization detector (PDHID).
• Support third-party software for detailed hydrocarbon analysis (DHA) and Chrom Merge.
• Support liquefied petroleum gas (LPG) sampling devices and vaporizers.
• Complete application manual and methods
• Best-in-Class Sensitivity• Unmatched Stability performance • Excellent Maintainability• Automation Functions
Nexis GC-2030
Trace Sulfur Analysis GC System
• Comprehensive gasoline measurements determining bulk PIONA and specific oxygenate and BTEX compound content.
• Provides a lot of information in a fast, robust measurement.• Relatively simple instrumentation, setup, and analysis
procedures.
VUV PIONA+ Analysis GC System
Trace Moisture Analysis GC System
• Easily analyzes both liquid and gas samples
• Uses a variety of WatercolTM GC columns depending on the matrices
• Uses a simple, high-sensitivity, and very stable low-cost Barrier Ionization Discharge (BID) Detector
Analysis of Water in LPGNote: With baseline subtraction
uV BID
Water 25 ppm,
RT= 14.3 min, S/N=350+LPG(Main)
2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 min
0
2500
5000
7500
10000
12500
15000
Natural Gas Analyzers
ASTM D1945/D1946
GPA 2261, GPA 2177
GPA 2286, GPA 2186
ISO 6975Applicable Methods
Analysis
Features
C1-C6+ Hydrocarbons, Non Condensable gases O2, N2, CO, CO2 and H2S
Optional Hydrogen
Extended NGA C1-C14+
NGL, Dual Oven NGA
High Speed NGA
Analysis time 10 min.
UOP 539, ASTM D7833,
D 2163
C1-C6+ Hydrocarbons
saturates and unsaturates
H2S, Non Condensable gases O2, N2, CO, CO2 and H2
LPG Sampling
Vaporizer
Analysis time less than
6 min.
ASTM D1946
ASTM E1746
O2, N2, CO, CO2
Impurities in Chlorine
Special Hastelloy
Material for Chlorine Analyzer
ASTM D3612C
TOGA with Head Space
H2, O2, N2, CO, CO2, C1, C2's, C3's
High Sensitivity
Extension up to C4
ASTM
D6228
Trace Sulfur
PFPD for Sulfur
Refinery Gas Analyzer (RGA)
Process and Custom Gas Analyzers
Petrochemicals analyzer
TOGA/DGA Analyzer SimulatedDistillation
ASTM D7096, D7213, D3710, D2887, D6417, D6352, D7500, D5307, D7169, IP 480, ISO3924
Boiling Point Distribution
C1-C110 (As per method)
Fast Simdist
Correlations with D86 and D1160, Integrated Shimadzu Software
ASTM D5134, D6729, D6730, D6733, D8071
C1-C14 Hydrocarbons
PIONA Report
Tuned D6730 column
Fast DHA
Front End PIONA
Room Temperature
Database
VUV PIONA+
ASTM D4815,D7423
UOP 960
C1-C4 Alcohols
Use of N2 Carrier for D4815
ASTM D6228
ASTM D5504
ASTM D5623
ASTM D7011
Trace Sulfur Analysis Individual components
Use of FPD, PFPD or SCD Detectors
ASTM D3606, 5580
Aromatics
Combination model for D3606, D5580. D4815
DHA Analyzers Oxygenates Analyzers Aromatics AnalyzersSulfur Analyzers
Product Lineup
4Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 5
Rel
ativ
e R
esp
on
se F
acto
r
1.3
1.2
1.1
1.0
0.9
0.8
0.70 50 100 150 200 250 300 350 400
Analysis time (Hours) (Day 16)
1-Butanethiol b.p. 98℃Methyl disulfide b.p. 109℃Diethyl disulfide b.p. 152℃3-Methylbenzothiophene b.p. 273℃
Excellent Long-Term StabilityVUV Chromatogram of Gasoline Sample
* The VUV detector VGA-100 is a product of VUV ANALYTICS, INC.
Sulfur Chemiluminescence Detection Gas Chromatograph System
SCD-2030
Aromatics AnalysisHPLC
Features
SwitchingValve
Configuration
SuperPerformance
andExpandability
PreciseSample
Injection
Furan AnalysisHPLC
Features
FullyIntegrated
System
NetworkConnectivity
HighSensitivityDetector
Applicable Methods ASTM D5837 Custom Methods
Analysis Subjects Components in transformer oil
15.0
12.5
10.0
7.5
5.0
2.5
0.0
PDA Ch1 Absorbance (220nm+/- 4nm) (+)mAV
Chromatogram View
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min
Furf
ury
alc
oh
ol/6
.452
/5.1
02
/7.2
33
/8.4
14
/9.3
78
Time Inten. 0.015Max Intensity : 7,116
0.000
15.0
12.5
10.0
7.5
5.0
2.5
0.0
PDA Ch2 Absorbance (282nm+/- 4nm) (+)mAV
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min
/7.2
33/7
.233
/8.4
14/8
.414
Time Inten. 0.029
Max Intensity : 14,654
2.044
5-h
ydro
xym
eth
yl-2
-fu
rald
ehyd
e/5.
102
5-h
ydro
xym
eth
yl-2
-fu
rald
ehyd
e/9.
388
2-fu
rald
ehyd
e/7.
233
2-fu
rald
ehyd
e/8.
414
Furan Chromatogram
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
00.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Applicable Methods ASTM D 6591, D6379, IP 391, IP 436, IP 548, IP590 Custom Methods
Analysis Subjects Aromatics in fuels Poly-aromatics in diesel
FAME in jet fuel
Aromatics Ref. Std. ASTMD6591
Non-Aromatics
Mono-Aromatics Di-Aromatics
Tri-Aromatics
LC / MS / MS
Features
VOCs AnalysisGC-MS
Features
LCMS-8060
High Speedand
High Sensitivity
Scan Speed30000u / sec
MRM555 Ch / Sec
Applicable Methods Custom Methods
Analysis Subjects Additives in polymers
MS Chromatograms of Polymer Additives
Analysis of Additives in Plastic
Applicable Methods EPA 8270B, TO -14, IP-585 Custom Methods
Analysis Subjects Volatile organic compounds Arsine phosphine in ethylene FAME in jet fuel
HS-20 Headspace Analysis System
TD-30 Thermal Desorption System
GCMS-QP2020 NX
Accessories HS,TD and P&T
High Sensitivityand Reduced
Cost
High EfficiencyMulticomponent
Analysis
6Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 7
Aromatics AnalysisHPLC
Features
SwitchingValve
Configuration
SuperPerformance
andExpandability
PreciseSample
Injection
Furan AnalysisHPLC
Features
FullyIntegrated
System
NetworkConnectivity
HighSensitivityDetector
Applicable Methods ASTM D5837 Custom Methods
Analysis Subjects Components in transformer oil
15.0
12.5
10.0
7.5
5.0
2.5
0.0
PDA Ch1 Absorbance (220nm+/- 4nm) (+)mAV
Chromatogram View
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min
Furf
ury
alc
oh
ol/6
.452
/5.1
02
/7.2
33
/8.4
14
/9.3
78
Time Inten. 0.015Max Intensity : 7,116
0.000
15.0
12.5
10.0
7.5
5.0
2.5
0.0
PDA Ch2 Absorbance (282nm+/- 4nm) (+)mAV
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 min
/7.2
33/7
.233
/8.4
14/8
.414
Time Inten. 0.029
Max Intensity : 14,654
2.044
5-h
ydro
xym
eth
yl-2
-fu
rald
ehyd
e/5.
102
5-h
ydro
xym
eth
yl-2
-fu
rald
ehyd
e/9.
388
2-fu
rald
ehyd
e/7.
233
2-fu
rald
ehyd
e/8.
414
Furan Chromatogram
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
00.0 2.5 5.0 7.5 10.0 12.5 15.0 17.5
Applicable Methods ASTM D 6591, D6379, IP 391, IP 436, IP 548, IP590 Custom Methods
Analysis Subjects Aromatics in fuels Poly-aromatics in diesel
FAME in jet fuel
Aromatics Ref. Std. ASTMD6591
Non-Aromatics
Mono-Aromatics Di-Aromatics
Tri-Aromatics
LC / MS / MS
Features
VOCs AnalysisGC-MS
Features
LCMS-8060
High Speedand
High Sensitivity
Scan Speed30000u / sec
MRM555 Ch / Sec
Applicable Methods Custom Methods
Analysis Subjects Additives in polymers
MS Chromatograms of Polymer Additives
Analysis of Additives in Plastic
Applicable Methods EPA 8270B, TO -14, IP-585 Custom Methods
Analysis Subjects Volatile organic compounds Arsine phosphine in ethylene FAME in jet fuel
HS-20 Headspace Analysis System
TD-30 Thermal Desorption System
GCMS-QP2020 NX
Accessories HS,TD and P&T
High Sensitivityand Reduced
Cost
High EfficiencyMulticomponent
Analysis
6Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 7
AA-7000
EDX-7000/8000/8100
Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
Features
ICP Atomic Emission Spectrometer (ICPE)
Features
Atomic Absorption Spectrophotometer (AAS)
Features
Energy DispersiveX-ray FluorescenceSpectrometer (EDX)
Features
Easy MethodDevelopment
LowestRunning Costs
High Stability,High Sensitivity
and LowInterference
Applicable Methods Customized
Analysis Subjects Trace elements in naphtha Determination of toxic arsenic species using LC-ICP-MS
Arsenic Chromatogram
AsVAsIII
DMAsAsB
Easy MethodDevelopment
Low ArgonConsumption
All WavelengthAcquisition
Applicable Methods Elemental Analysis ASTM D4951, D5184 ASTM D4951,D5184 UOP 389, UOP 303 UOP 714, APHA 3120, IFP 9507
Analysis Subjects All elements Lubricating oils Petroleum naphtha, gasoline Marine fuel, fuel oil, heavy oils
Cr in Naphtha with ISO Mist Kit
Cr 267.716Cond 2
Inte
nsity
Inte
nsity
ICPE-9800 Series
Applicable Methods ASTM D6595, D3237, D3567, D3605, D3635, D3831,
D3919, D4628, IFP9312, UOP946, D5863
Analysis Subjects Additives in polymers All elements Lubricating oil Petroleum oils Lead in gasoline
Abs=0.011100Conc+0.0043463 r=0.9989
0.000 5.000 10.000 15.000 20.000Conc(NONE)
0.000
0.100
0.200Abs
Arsenic in Vacuum Gas Oil (VGO)
Unique 3DDouble Beam
Optics
ComprehensiveSafety Functions
DualBackgroundCorrectionFunctions
Applicable Methods ASTM D5839, ASTM D4294, C114 ISO 8754
Analysis Subjects Sulfur in oil All elements
Zn in Lubricant Oil
10.0
8.0
6.0
4.0
2.0
0.0
002
001
003
004
Mea
sure
d In
ten
sity
(cp
s/u
A)
Standard Value (ppm)
0.0 50.0 100.0 150.0 200.0 250.0 300.0
High Sensitivity,High Speed andHigh Resolution
Large SampleChamber
Easy-To-UseOperation
8Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 9
AA-7000
EDX-7000/8000/8100
Inductively Coupled Plasma Mass Spectrometer (ICP-MS)
Features
ICP Atomic Emission Spectrometer (ICPE)
Features
Atomic Absorption Spectrophotometer (AAS)
Features
Energy DispersiveX-ray FluorescenceSpectrometer (EDX)
Features
Easy MethodDevelopment
LowestRunning Costs
High Stability,High Sensitivity
and LowInterference
Applicable Methods Customized
Analysis Subjects Trace elements in naphtha Determination of toxic arsenic species using LC-ICP-MS
Arsenic Chromatogram
AsVAsIII
DMAsAsB
Easy MethodDevelopment
Low ArgonConsumption
All WavelengthAcquisition
Applicable Methods Elemental Analysis ASTM D4951, D5184 ASTM D4951,D5184 UOP 389, UOP 303 UOP 714, APHA 3120, IFP 9507
Analysis Subjects All elements Lubricating oils Petroleum naphtha, gasoline Marine fuel, fuel oil, heavy oils
Cr in Naphtha with ISO Mist Kit
Cr 267.716Cond 2
Inte
nsity
Inte
nsity
ICPE-9800 Series
Applicable Methods ASTM D6595, D3237, D3567, D3605, D3635, D3831,
D3919, D4628, IFP9312, UOP946, D5863
Analysis Subjects Additives in polymers All elements Lubricating oil Petroleum oils Lead in gasoline
Abs=0.011100Conc+0.0043463 r=0.9989
0.000 5.000 10.000 15.000 20.000Conc(NONE)
0.000
0.100
0.200Abs
Arsenic in Vacuum Gas Oil (VGO)
Unique 3DDouble Beam
Optics
ComprehensiveSafety Functions
DualBackgroundCorrectionFunctions
Applicable Methods ASTM D5839, ASTM D4294, C114 ISO 8754
Analysis Subjects Sulfur in oil All elements
Zn in Lubricant Oil
10.0
8.0
6.0
4.0
2.0
0.0
002
001
003
004
Mea
sure
d In
ten
sity
(cp
s/u
A)
Standard Value (ppm)
0.0 50.0 100.0 150.0 200.0 250.0 300.0
High Sensitivity,High Speed andHigh Resolution
Large SampleChamber
Easy-To-UseOperation
8Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 9
10Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 11
DSC-60 PlusIRSpirit
UV-1900
Fourier Transform Infrared Spectrophotometer (FTIR)
Features
UV-VIS Spectrophotometer (UV-Vis)
Features
Thermal Analyzers
Features
Spectrofluorophotometer
Features
Space Efficient with High
Expandability
Dedicated IR Pilot Program
HighReliability
Applicable Methods D7371, EN 14078, D7575, D7678 Custom Methods
Analysis Subjects Fame in biodiesel Total petroleum hydrocarbons Additives in polymers Oil in water
Enlarged View of PeaksAround 2920 cm-1
27202740276027802800282028402860288029002920294029602980300030203040306030803100cm-1
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Abs
CSD1CSD2CSD3CSD4CSD5CSD6CSD7
Sample AbsorbanceConcentration
[ppm]
CSD1 0.0020 0.73
CSD2 0.026 4.54
CSD3 0.096 15.23
CSD4 0.28 40.56
CSD5 0.60 87.57
CSD6 0.87 127.55
CSD7 1.2 168.70
r=1.0
Height
Calibration Curve and StandardSample Concentrations
Analysis of Oil in Water
Easy Operation
Allows Obtaining AnswersRapidly
Advanced Regulatory Compliance
High Performance to Meet Diverse
Needs
Applicable Methods ASTM D1840, D2008 Custom Methods
Analysis Subjects Petroleum products Turbine fuels Mineral oils
Transmittance Spectra of Colored Cellophane Tape Chromaticity Diagram of XY Color System
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
100
80
60
40
20
0
0.00
380 500 600Wavelength (nm)
700 780
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80x
y
Tran
smit
tan
ce (
%)
Analysis of Colored Cellophane Tape
HighPerformance
DSC / TGA
DiverseMeasurements
by SimpleOperations
HighSensitivity
Applicable Methods ASTM D3417, D3418, D4419, D4591, D5483, ASTM D3850, D6370, D6375, Custom Methods
Analysis Subjects Thermal properties of polymers DSC, TGA, TG/DTA, TMA
DSC Curves of HDPE, PP, and Blend Sample
-0 50 100 150 200
135.5 °C
160.5 °C
20.00 °C
869.90 mJ
144.90 °C 175.00 °C
72.04 mJ
-203.67 J/g
132.9 °C
-95.46 J/g163.4 °C
20.00 °C 144.90 °C 175.00 °C
69.76 J/g
HDPE
PP
Blend (PE8-PP2)
mW
-0
10
20
30
40
Temp [°C]
DSC
High SensitivityHigh Stability
andHigh Speed
High Speed3D Scanning
FluorescenceQuantum Yield
and FluorescenceQuantumEfficiency
Measurement
RF-6000
Applicable Methods ASTM D5412, JPI-5S-71-2010 Custom Methods
Analysis Subjects Measuring oil in water Coumarin in diesel
Coumarin in DieselFl
uore
scen
ce In
tens
ity
150000.0
100000.0
50000.0
0.0390.0 450.0 500.0 550.0 600.0 630.0
nm
Calibration Curve
Concentration (mg/L)
Flu
ore
scen
ce In
tens
ity
10Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 11
DSC-60 PlusIRSpirit
UV-1900
Fourier Transform Infrared Spectrophotometer (FTIR)
Features
UV-VIS Spectrophotometer (UV-Vis)
Features
Thermal Analyzers
Features
Spectrofluorophotometer
Features
Space Efficient with High
Expandability
Dedicated IR Pilot Program
HighReliability
Applicable Methods D7371, EN 14078, D7575, D7678 Custom Methods
Analysis Subjects Fame in biodiesel Total petroleum hydrocarbons Additives in polymers Oil in water
Enlarged View of PeaksAround 2920 cm-1
27202740276027802800282028402860288029002920294029602980300030203040306030803100cm-1
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Abs
CSD1CSD2CSD3CSD4CSD5CSD6CSD7
Sample AbsorbanceConcentration
[ppm]
CSD1 0.0020 0.73
CSD2 0.026 4.54
CSD3 0.096 15.23
CSD4 0.28 40.56
CSD5 0.60 87.57
CSD6 0.87 127.55
CSD7 1.2 168.70
r=1.0
Height
Calibration Curve and StandardSample Concentrations
Analysis of Oil in Water
Easy Operation
Allows Obtaining AnswersRapidly
Advanced Regulatory Compliance
High Performance to Meet Diverse
Needs
Applicable Methods ASTM D1840, D2008 Custom Methods
Analysis Subjects Petroleum products Turbine fuels Mineral oils
Transmittance Spectra of Colored Cellophane Tape Chromaticity Diagram of XY Color System
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
100
80
60
40
20
0
0.00
380 500 600Wavelength (nm)
700 780
0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80x
y
Tran
smit
tan
ce (
%)
Analysis of Colored Cellophane Tape
HighPerformance
DSC / TGA
DiverseMeasurements
by SimpleOperations
HighSensitivity
Applicable Methods ASTM D3417, D3418, D4419, D4591, D5483, ASTM D3850, D6370, D6375, Custom Methods
Analysis Subjects Thermal properties of polymers DSC, TGA, TG/DTA, TMA
DSC Curves of HDPE, PP, and Blend Sample
-0 50 100 150 200
135.5 °C
160.5 °C
20.00 °C
869.90 mJ
144.90 °C 175.00 °C
72.04 mJ
-203.67 J/g
132.9 °C
-95.46 J/g163.4 °C
20.00 °C 144.90 °C 175.00 °C
69.76 J/g
HDPE
PP
Blend (PE8-PP2)
mW
-0
10
20
30
40
Temp [°C]
DSC
High SensitivityHigh Stability
andHigh Speed
High Speed3D Scanning
FluorescenceQuantum Yield
and FluorescenceQuantumEfficiency
Measurement
RF-6000
Applicable Methods ASTM D5412, JPI-5S-71-2010 Custom Methods
Analysis Subjects Measuring oil in water Coumarin in diesel
Coumarin in Diesel
Fluo
resc
ence
Inte
nsity
150000.0
100000.0
50000.0
0.0390.0 450.0 500.0 550.0 600.0 630.0
nm
Calibration Curve
Concentration (mg/L)
Flu
ore
scen
ce In
tens
ity
AG-Xplus Series
Total Organic Carbon (TOC) Analyzer
Features
On-line TOC Analyzer
Features
Testing Machines
Features
Particle Size Analyzer
Features
Applicable Methods ASTM D7573, EN 1484, EPA 415.1 APHA 5310B
Analysis Subjects TOC in various types of water, including high salt content water
TOC in Brine Solution
TOC-L Series
680 DegCCombustion
MethodHigh Salt Kit
StandaloneSystem
SuperiorSampling
Units
LowOperation
Costs
LowMaintenance
Costs
Applicable Methods Custom Methods
Analysis Subjects TOC in various types of water
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0,00
NPO
C in
mg
/I
Number of Measurements
1 20 39 58 77 96 115 134 153 172 191 210 229 248 267
TOC Analysis in Condensate SampleMean Value 0.208mg/L, SD 0.006mg/L, DL 0.05mg/L
Short TestCycle Time
UltrafastSampling Rate
Eight FoldHigh
Resolution
Applicable Methods ISO 6892, ISO 527, ASTM D638
Analysis Subjects Tensile properties of metals Tensile properties of plastics
Tensile Test of PP, PC, PVC
Applicable Methods Custom Methods
Analysis Subjects Various petrochemicals streams
Samples with Broad Distribution
Polystyrene Latex ○ : 50nm, ● : 100nm, △ : 50nm + 100nm
No
rmal
ized
Par
ticl
e A
mo
un
t
Particle Diameter (nm)
No
rmal
ized
Par
ticl
e A
mo
un
tParticle Diameter (nm)
SALD-2300
Wide Range17nm-2500um
Wide Rangeof Accessories
HighSensitivity / HighConcentration
12Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 13
0
10
20
30
40
50
60
70
80
90
100
010 20 30 40 50 60 70 80 90 100 110 120
Displacement (Strain) (%)
Stre
ss (N
/mm
2 )
PP_1PC_1PVC_1
AG-Xplus Series
Total Organic Carbon (TOC) Analyzer
Features
On-line TOC Analyzer
Features
Testing Machines
Features
Particle Size Analyzer
Features
Applicable Methods ASTM D7573, EN 1484, EPA 415.1 APHA 5310B
Analysis Subjects TOC in various types of water, including high salt content water
TOC in Brine Solution
TOC-L Series
680 DegCCombustion
MethodHigh Salt Kit
StandaloneSystem
SuperiorSampling
Units
LowOperation
Costs
LowMaintenance
Costs
Applicable Methods Custom Methods
Analysis Subjects TOC in various types of water
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0,00
NPO
C in
mg
/I
Number of Measurements
1 20 39 58 77 96 115 134 153 172 191 210 229 248 267
TOC Analysis in Condensate SampleMean Value 0.208mg/L, SD 0.006mg/L, DL 0.05mg/L
Short TestCycle Time
UltrafastSampling Rate
Eight FoldHigh
Resolution
Applicable Methods ISO 6892, ISO 527, ASTM D638
Analysis Subjects Tensile properties of metals Tensile properties of plastics
Tensile Test of PP, PC, PVC
Applicable Methods Custom Methods
Analysis Subjects Various petrochemicals streams
Samples with Broad Distribution
Polystyrene Latex ○ : 50nm, ● : 100nm, △ : 50nm + 100nm
No
rmal
ized
Par
ticl
e A
mo
un
t
Particle Diameter (nm)
No
rmal
ized
Par
ticl
e A
mo
un
t
Particle Diameter (nm)
SALD-2300
Wide Range17nm-2500um
Wide Rangeof Accessories
HighSensitivity / HighConcentration
12Shimadzu's Total Solutions for the Hydrocarbon Processing Industry
Analytical and Testing Instruments for the HPI Market 13
0
10
20
30
40
50
60
70
80
90
100
010 20 30 40 50 60 70 80 90 100 110 120
Displacement (Strain) (%)St
ress
(N/m
m2 )
PP_1PC_1PVC_1
The Next Industry Standard SCDThe Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system.
It has been developed to fulfill the unmet needs of laboratories the world over.
The dramatically enhanced sensitivity and reliability, the excellent maintainability,
and the automation functions, a first for the industry, will improve laboratory productivity.
Sulfur Chemiluminescence Detection Gas Chromatograph System
SCD-2030
The New Standard in Reliability
Dramatically Improved Productivity
Best-in-Class Sensitivity
*2 It is not necessary to install LabSolutions software on the client PC for terminal service.*3 When using an iPad, the installation of Citrix’s XenApp is required. iPad is a registered trademark of Apple Inc.
*1 The acquisition controller PC controls the analytical instruments. Analysis directions and re-analysis of data can be performed using a client PC.
Laboratory or office*2Client PC *3iPad LabSolutions server
*1***1Acquisition controller PC Acquisition controller PC
Shimadzu LC Shimadzu GC Shimadzu GCShimadzu LC Agilent GC Agilent GCAgilent LC Agilent LC
Controlling other vendor’s GC and HPLC using LabSolutions DB/CS
Simple User Interface
LabSolutions CS
Agilent LC method editing
Agilent GC method editing
Agilent LC batch editing Agilent LC analysis monitoring
Agilent GC batch editing Agilent GC analysis monitoring
Launcher window
Shimadzu Analytical Network Data System
14 15
The Next Industry Standard SCDThe Nexis SCD-2030 is a next-generation sulfur chemiluminescence detection system.
It has been developed to fulfill the unmet needs of laboratories the world over.
The dramatically enhanced sensitivity and reliability, the excellent maintainability,
and the automation functions, a first for the industry, will improve laboratory productivity.
Sulfur Chemiluminescence Detection Gas Chromatograph System
SCD-2030
The New Standard in Reliability
Dramatically Improved Productivity
Best-in-Class Sensitivity
*2 It is not necessary to install LabSolutions software on the client PC for terminal service.*3 When using an iPad, the installation of Citrix’s XenApp is required. iPad is a registered trademark of Apple Inc.
*1 The acquisition controller PC controls the analytical instruments. Analysis directions and re-analysis of data can be performed using a client PC.
Laboratory or office*2Client PC *3iPad LabSolutions server
*1***1Acquisition controller PC Acquisition controller PC
Shimadzu LC Shimadzu GC Shimadzu GCShimadzu LC Agilent GC Agilent GCAgilent LC Agilent LC
Controlling other vendor’s GC and HPLC using LabSolutions DB/CS
Simple User Interface
LabSolutions CS
Agilent LC method editing
Agilent GC method editing
Agilent LC batch editing Agilent LC analysis monitoring
Agilent GC batch editing Agilent GC analysis monitoring
Launcher window
Shimadzu Analytical Network Data System
14 15
Shimadzu's Total Solutions for the H
ydrocarbon Processing IndustryC10G-E067A
www.shimadzu.com/an/
Analytical and Testing Instruments for the HPI Market
Shimadzu's Total Solutions for theHydrocarbon Processing Industry
© Shimadzu Corporation, 2019
For Research Use Only. Not for use in diagnostic procedures. This publication may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation, its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether or not they are used with trademark symbol “TM” or “®”.Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.