c oxygen systems and vehicular equipment en 0611

10
C1 Oxygen Systems and Vehicular Equipment Oxygen Systems and Vehicular Equipment Reliable supply of oxygen

Upload: defensetechs

Post on 19-Feb-2015

268 views

Category:

Documents


19 download

DESCRIPTION

C1Oxygen Systems and Vehicular EquipmentOxygen Systems and Vehicular EquipmentReliable supply of oxygenOxygen Systems and Vehicular EquipmentC2A good outcome depends on the safe and exact dosage of oxygen in an emergency. Our products for your oxygen systems and emergency vehicles guarantee top quality that you can rely on 100%. A reliable supply of oxygen is ensured by our OXYWAY pressure reducers and flowregulators, oxygen cylinders, pressure reducer connectors and a broad range [email protected]

TRANSCRIPT

Page 1: C Oxygen Systems and Vehicular Equipment en 0611

C1 Oxygen Systems and Vehicular Equipment

Oxygen Systems and Vehicular Equipment

Reliable supply of oxygen

Page 2: C Oxygen Systems and Vehicular Equipment en 0611

Oxygen Systems and Vehicular Equipment C2

A good outcome depends on the safe and exact dosage of oxygen in an emergency. Our products for your oxygen

systems and emergency vehicles guarantee top quality

that you can rely on 100%. A reliable supply of oxygen

is ensured by our OXYWAY pressure reducers and flow

regulators, oxygen cylinders, pressure reducer connectors

and a broad range of accessories. We promise dependabil- ity for long-term oxygen supplies at the scene of an emer-

gency, during long transport routes and for simultaneous treatment of several patients.

Page 3: C Oxygen Systems and Vehicular Equipment en 0611

OXY

W 21,8/21,7“

cylinders. You

C3 Oxygen Systems and Vehicular Equipment

OXYWAY Pressure reducer and flow regulator You can rely on the accuracy of OXYWAY pressure reducers and flow regulators. For only the properly dosed supply of oxygen can achieve the desired effect in the ventilation of your patients. Our OXYWAY pressure reducers and flow regulators, which we offer in several variants, can be used in many different ways in

the practice of oxygen and emergency medicine. All are avail- able with up to two oxygen outlets (see page C4): flow outlet and pressure outlet. The former is used to supply oxygen di- rectly to the patient while the latter guarantees a safe supply of oxygen delivered via a ventilator and oxygen administrator.

1 Flow outlet U NF 9/16“ 2 Pressure outlet G 3/8“

and WAY Fast II

or

OXYWAY Fix OXYWAY Fine OXYWAY Fast I OXYWAY Click

OXYWAY Fix for permanently set oxygen flow of 4 l/min or 120 l/min for MEDUMAT-ventilators

Features:

OXYWAY Fine for infinitely adjustable oxy- gen flow of 0.5–3/1.5–8 / 3–15 l/min with contents and flow gauge

OXYWAY Fast for infinitely adjustable oxy- gen flow dosage in levels 1/ 2/3/4/5/6/9/12/15 l/min or 0.5/1/1.5/2/2.5/3/4/5/6 l/min

OXYWAY Click for flow dosage via a central gas system in rescue services and hospitals

Greatest level of operating safety with ultrasonic-tested high- pressure housing and dual sinter filter “Made in Germany“ quality– with more than 40 years of experience in the manufacture of pressure reducers Observance of all relevant safety standards and norms Flow levels that are easy to set and check Low maintenance: The interim maintenance after two years can be done by the user.

Country-specific threads for pressurized connections (e.g., PIN, Bullnose, DIN) Range of connection bolt lengths (15-140 mm) available; high-pressure connectors mounted left or right as required

Variability on device outlet (straight or angled connection nozzles, disposable or reusable humidifiers, flow meters, suction injector, administrators, country-specific standard couplings) Only with OXYWAY Fast and OXYWAY Click: flow setting can be read from both sides

International connections for pressure reducers and oxygen cylinders

Because international standards differ, some countries require different connections for pressure reducers and oxygen can acquire from us the commercially available international standard connections (see below) and customized connection variants.

NGO G 3/4“ G 5/8“ 90° Bullnose

G 5/8“ 72° Bullnose

G 5/8“ 60° Bullnose

PI N- Index

Page 4: C Oxygen Systems and Vehicular Equipment en 0611

Fi

Oxygen Systems and Vehicular Equipment C4

OXYWAY

- Order

number

- NSN1)

Outlet UNF 9/16“ Pressure outlet Gauge

Country-specific inlet connections2 )

Connection bolt length and position (option: right or left), connec- tion bolt length from 15 mm to 140 mm available)

Fix I 30051 - 1x UNF 9/16“

- 4 l/min - side

– Contents gauge G ¾“

(DE, CH, IL, AT)

- 30 mm - right

Fix III 30301 – - 1x G 3/8“ - 120 l/min - bottom

Contents gauge G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fix III 30421 – - 1x quick coupling as per DIN 13260

- 120 l/min - bottom

Contents gauge G ¾“ (DE, CH, IL, AT)

- 50 mm - right

Fine I 30501 - 1x UNF 9/16“

- infinitely adjustable - 3 – 15 l/min - bottom

– Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

ne II 30701 - 1x UNF 9/16“

- infinitely adjustable - 1.5 – 8 l/min - bottom

– Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fine III WM 30751 - 1x UNF 9/16“

- infinitely adjustable - 0,5 – 3 l/min - bottom

– Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast I WM 30801

NSN: 6680-12- 383-0781

- 1x UNF 9/16“ - dosage settings lock into

place at: 1/2/3/4/5/6/9/12/15 l/min

- bottom

– Contents gauge G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast II WM 308513) - 1x UNF 9/16“ - dosage settings lock into

place at: 1/2/3/4/5/6/9/12/15 l/min

- bottom Fast II WM 308413) - 1x UNF 9/16“

- dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min

- bottom

- 1x G 3/8“ - 90 l/min - bottom - 1x quick coupling

as per DIN 13260 - 90 l/min - bottom

Contents gauge G ¾“ (DE, CH, IL, AT)

Contents gauge G ¾“

(DE, CH, IL, AT)

- 30 mm - right - 30 mm - right

Fast II High Flow

WM 31891

NSN: 6680-12- 383-2243

- 1x UNF 9/16“ - dosage settings lock into

place at: 1/2/3/4/5/6/9/12/15 l/min

- top

- 1x G 3/8“ - free flow:

about 190 l/min - bottom

Contents gauge G ¾“ (DE, CH, IL, AT)

- 30 mm - left

Fast III WM 30601 - 1x UNF 9/16“ - dosage settings lock into

place at: 0.5/1/1.5/2/2.5/3/4/5/6 l/min

- bottom

– Contents gauge G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Click Flow dosage

Click Flow dosage

WM 31030 1x UNF 9/16“ - dosage settings lock into

place at: 1/2/3/4/5/6/9/12/15 l/min

- bottom WM 31040 1x UNF 9/16“

- dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min

- bottom

– – Plug complies with – DIN 13260 for central gas system

– – AGA plug for central –

gas system

1) NSN: NATO Stock Number 2) Ordering info: final digit of number refers to connector type, e.g.,

3) NOTE: WM 30851 and 30841 are not to be used with MEDUMAT Variable, MEDUMAT Control, MEDUMAT Compact and MEDUMAT Elektronik

WM 30301 = G ¾“ WM 30302 = G 5/8“, 60° Bullnose WM 30303 = G 5/8“, 72° Bullnose WM 30304 = W21,8/ 21,7

WM 30305 = NGO, CGA 540 WM 30306 = PIN Index WM 30307 = G 5/8, 90° Bullnose

Please note that the connection nozzles for all pressure reducers have to be ordered separately. Please ask our Customer Service for advice. N OT E : other country-specific connectors are available upon request

Page 5: C Oxygen Systems and Vehicular Equipment en 0611

2 3

C5 Oxygen Systems and Vehicular Equipment

Accessories

1 4

WM 31122 WM 31130 WM 31140 WM 1415

5 6 7 8

WM 1470 WM 22319 WM 1475 WM 2057

9 10 11 12

WM 22345 WM 22252 WM 22296 WM 22929

Accessories

Connect ion nozzles UN F 9/16“ 1 Straight nozzle

WM 31122 Ø 6 mm, with swivel nut UNF 9/16“, female threads (chrome-plated) and seal

2 90° Angle d nozzle WM 31130 Ø 6 mm, with swivel nut UNF 9/16“ female threads (chrome-plated) and seal

3 90° Angle d nozzle WM 31140 Ø 6 mm, with wing nut UNF 9/16“ female threads (chrome-plated) and seal

hose connection nozzle G 3/8“

4 Straight nozzle WM 1415 (NATO Stock Number 4730-12-368-4912) Ø 6,7 mm, with swivel nut G 3/8“ female threads (chrome-plated) and seal, suitable for hoses Ø 6 mm interior diameter (WM 1411)

5 Straight nozzle WM 1470 Ø 5,2 mm, with swivel nut(chrome-plated) G 3/8“ female threads and seal, suitable for hoses Ø 5 mm interior diameter (WM 2081)

6 90° Angle d nozzle WM 22319 Ø 5,2 mm, with swivel nut (chrome-plated) G 3/8“ female threads and seal

7 90° Angled nozzle WM 1475 Ø 5,2 mm, with wing nut (chrome-plated) G 3/8“ female threads and seal

Nozzle with two outlets (not shown) (not shown) WM 1472 Ø 5.2 mm, with wing nut (chrome-plated) G 3/8“ female threads and seal

Central gas supply connector for oxygen 8 Angled connector complies with DIN 13260

WM 2057

9 Angled connector, AGA WM 22345

10 Angled connector, bayonet (AFN O R) WM 22252

11 Straight connector, bayonet (AFNO R) WM 22296

Angled connector 45° complies with British Standard 5682 WM 28627 (not shown)

12 SIS screw connector, complies with AS 2896 WM 22929 for central gas system, complies with Australian norm

Page 6: C Oxygen Systems and Vehicular Equipment en 0611

Oxygen Systems and Vehicular Equipment C6

1 2 3 4 5

WM 3799 WM 3910 WM 1289 WM 8220

WM 3949

6 7 8 9 10

WM 3950

WM 1485 WM 1412 WM 22584

WM 1231

Additional accessories (e.g., administrators and adapters)

1 Connector for oxygen quick coupling WM 3799 (NATO Stock Number 6515-12-343-6142) angled 90° (accessory required for assembly: WM 2078) - oxygen cap (Walther), nominal size 4 mm, - hose connection Ø 6 mm

2 T-shaped distributor WM 3910 (NATO Stock Number 4730-12-323-8076) with swivel nut G 3/8“ female threads, G 3/8“ male threads and oxygen quick coupling (Walther)

3 T-shaped distributor WM 1289 (NATO Stock Number 4730-12-368-6643) with wing nut G 3/8“ female threads and 2x G 3/8“ male threads

4 T-shaped distributor with check valve WM 8220 with swivel nut G 3/8“ female threads, G 3/8“ male threads and oxygen quick coupling (Walther)

5 Adapter for connector, complies with DIN 13260 WM 3949 with swivel nut G 3/8“ female threads, 20 cm hose and hose coupling, complies with DIN 13260

6 Adapter for plug complies with DIN 13260 WM 3950 with swivel nut G 3/8“ female threads, 20 cm hose and hose coupling complies with DIN 13260

7 Adapter WM 1485 with swivel nut G 3/8“ female threads and oxygen quick coupling (Walther)

8 Screw nozzle WM 1412 with G 3/8“ male threads and hose connector Ø 4,4 mm

9 NIST Adapter WM 22584 with G 3/8“ female threads and NIST male threads for MEDUMATs, MODULs and OXY WAY pressure reducers

10 Screw-t ype blank cap with G 3/8“ WM 1231 with G 3/8“ female threads to seal connectors with G 3/8“ male threads (such as MEDUMAT Transport)

Page 7: C Oxygen Systems and Vehicular Equipment en 0611

e on Page A15.

r

C7 Oxygen Systems and Vehicular Equipment

1 2

WM 1929 WM 1925

3 4 WM 22210

WM 1921 WM 1429

WM 22200

MODUL Oxygen WM 22200, NATO Stock Number 6515-12-369-0636 Infinitely adjustable oxygen inhalation from 0 to 15 liters/min, with O2 quick coupling (Walther) and straight connection nozzle for inhalation hose.

MODUL Combi WM 22210, NATO Stock Number 6515-12-378-2376 Suction and oxygen inhalation from 0 to 15 liters/min, suction fixed at – 0,5 bar, with O2 quick coupling (Walther) and connection socket for inhalation hose and test pressure gauge

Note

Detailed descriptions of MODUL Combi and MODUL Oxygen a

They can be installed in an emergency vehicle and integrated on a LIFE-BASE portable system (see Section B).

Nasal cannula 1 Nasal cannula for babies, double lumen with

2.1-meter connection hose WM 1920 – Set I: 20 nasal cannula (20 x WM 1920) WM 15341 – Set II: 40 nasal cannula (40 x WM 1920) WM 15342 – Set III: 100 nasal cannula (100 x WM 1920) WM 15343

2 Nasal cannula for children, double lumen with 2.1-meter connection hose WM 1921 – Set I: 20 nasal cannula (20 x WM 1921) WM 15344 – Set II: 40 nasal cannula (40 x WM 1921) WM 15345 – Set III: 100 nasal cannula (100 x WM 1921) WM 15346

3 Nasal cannula for adults, double lumen with 1.5-meter connection hose WM 1925 – Set I: 20 nasal cannula (20 x WM 1925) WM 15251 – Set II: 40 nasal cannula (40 x WM 1925) WM 15252 – Set III: 100 nasal cannula (100 x WM 1925) WM 15222 Nasal cannula for adults, double lumen with earpiece and 1.5-meter connection hose (not shown) WM 1929 – Set I: 20 nasal cannula (20 x WM 1929) WM 15220 – Set II: 40 nasal cannula (40 x WM 1929) WM 15225 – Set III: 100 nasal cannula (100 x WM 1929) WM 15221

Inhalation masks

4 Oxygen inhalation masks, plastic with connection hose WM 1429 NATO Stock Number 6515-12-350-8835 – Set I: 6 oxygen inhalation masks

(6 x WM 1429) WM 15210 – Set II: 12 oxygen inhalation masks

(12 x WM 1429) WM 15215

Page 8: C Oxygen Systems and Vehicular Equipment en 0611

Oxygen Systems and Vehicular Equipment C8

WM 22303

Pressure hose

Hose of medical-grade PVC, white, 10 bar, internal diameter 5 mm, wall thickness 3 mm (WM 2081). Other hose lengths are available upon request.

Hose connector A Hose connector B Length Order Number

Swivel nut G 3/8“ female threads with angled connection nozzle Swivel nut G 3/8“ female threads with angled connection nozzle 35 cm WM 22315

Swivel nut G 3/8“ female threads with straight connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle 45 cm WM 22320

Swivel nut G 3/8“ female threads with angled connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle 47 cm WM 22367

Swivel nut G 3/8“ female threads with straight connection nozzle Swivel nut G 3/8“ female threads with straight connection nozzle 1 m WM 22301

Swivel nut G 3/8“ female threads with straight connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle 1 m WM 22302

Swivel nut G 3/8“ female threads with angled connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle 1 m WM 22305

Swivel nut G 3/8“ female threads with straight connection nozzle Screw nozzle with male threads G 3/8 1 m WM 22316

Swivel nut G 3/8“ female threads with angled connection nozzle

SIS-Screw connection for Australian central gas system ZGA (complies with AS 2896)

2 m WM 22000

Walther male connector Swivel nut G 3/8“ female threads with straight connection nozzle 3 m WM 22306

Walther male connector Swivel nut G 3/8“ female threads with angled connection nozzle 3 m WM 22307

O2 male connector (DIN 13260-compliant) for central gas supply outlet

Walther male connector 3 m WM 22303

O2 male connector (DIN 13260-compliant) for central gas supply outlet Swivel nut G 3/8“ female threads with angled connection nozzle 3 m WM 22312

O2 male connector (DIN 13260-compliant) for central gas supply outlet

Swivel nut G 3/8“ female threads with straight connection nozzle 3 m WM 22308

O2 male connector (bayonet AFNOR) for central gas supply outlet Walther male connector 3 m WM 22304

O2 male connector (bayonet AFNOR) for central gas supply outlet Swivel nut G 3/8“ female threads with straight connection nozzle 3 m WM 22311

O2 male connector (bayonet AFNOR) for central gas supply outlet Swivel nut G 3/8“ female threads with angled connection nozzle 3 m WM 22314

O2 male connector (bayonet AFNOR) for central gas supply outlet, O2 male connector (bayonet AFNOR) for central gas supply outlet straight

3 m WM 22371

O2 male connector (AGA) for central gas supply outlet Swivel nut G 3/8“ female threads with straight connection nozzle 3 m WM 22309

Page 9: C Oxygen Systems and Vehicular Equipment en 0611

9

C9 Oxygen Systems and Vehicular Equipment

Oxygen administrators Oxygen administrators deliver a flow of oxygen to patient(s). The functions inhalation, ventilation and suction can be set up

independent of each other but can be supplied by a single gas source.

1 5

WM 3720 WM 3740

2 6

WM 3820 WM 3743

3 7

WM 3730 WM 3750

4 8

WM 3832 WM 3880

Accessories

1 Oxygen administrator with two outlets WM 3720 Inlet: 1 x G 3/8“ wing nut, top Outlet: 2 x G 3/8“ male thread, free

WM 3714 (not shown) reverse screw-on type Inlet: 1 x G 3/8“ male thread, top Outlet: 2 x G 3/8“ male thread, free

2 Oxygen administrator with two outlets WM 3820 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min

1 x UNF 9/16“ male thread, 10 l/min

3 Oxygen administrator with three outlets WM 3730 Inlet: 1 x G 3/8“ wing nut, top Outlet: 3 x G 3/8“ male thread, free

WM 3834 (not shown) Inlet: 1 x G 3/8“ male thread, top Outlet: 3 x UNF 9/16“ male thread, 10 l/min,

incl. 3 x WM 31130 angled connector

4 Oxygen administrator with three outlets WM 3832 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min

2 x UNF 9/16“ male thread, 10 l/min

5 Oxygen administrator with four outlets WM 3740 Inlet: 1 x G 3/8“ wing nut, top Outlet: 4 x G 3/8“ male thread, free

6 Oxygen administrator with four outlets WM 3743 Inlet: 1 x G 3/8“ male thread, top Outlet: 3 x G 3/8“ male thread, free

1 x G 3/8“ male thread, secretion, 13 l/min

7 Oxygen administrator with four outlets WM 3750 Inlet: 1 x G 3/8“ wing nut, left Outlet: 3 x UNF 9/16“ male thread, 10 l/min

1 x G 3/8“ male thread, secretion, 13 l/min

8 Oxygen administrator with four dosage setting stops for outlets WM 3880 Outlet: 4 x UNF 9/16“ male thread, 0-15 l/min,

dosage clicks into place, incl. 4 x WM 31122 connection nozzle

Inlet / Outlet: 3 x G 3/8“ male thread, top, bottom, right

Cut-off valve

9 Cut-off valve with two outlets WM 3737 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min

1 x G 3/8“ male thread, free, closed with cap

Page 10: C Oxygen Systems and Vehicular Equipment en 0611

4

Oxygen Systems and Vehicular Equipment C10

1 2 3 5

WM 1818

WM 1814 WM 1822

WM 1805

WM 1885 WM 1825

Cylinder bracket WM 1885 Set of two for stationary O2 facilities in buildings or vehicles for two-liter and three-liter oxygen cylinders, Ø 100 mm (complies with Norm EN 1789)

WM 1889 (not shown) (NATO Stock Number 2590-12-368-6436) Set of two for stationary O2 facilities in buildings or vehicles for five-liter, 10-liter and 11-liter oxygen cylinders, Ø 140 mm (complies with Norm EN 1789)

Oxygen cylinder Empty, with G ¾“ connection thread* 1 WM 1818-02

0.8-liter x 200 bar, capacity = 160 liter O2

2 WM 1814-02

Lightweight oxygen cylinder of aluminum, 2-liter x 200 bar, capacity = 400 liter O2

3 WM 1822-02, NATO Stock Number 6505-12-362-1019

2-liter x 200 bar, capacity = 400 liter O2

4 WM 1805-02, NATO Stock Number 6505-12-382-2129

5-liter x 200 bar, capacity = 1000 Liter O2

5 WM 1825-02, NATO Stock Number 6505-12-321-1981

10-liter x 200 bar, capacity = 2000 liter O2, with safety cap and collar, integrated base

WM 1830-02 (not shown)

similar to WM 1825, but with 11 l x 200 bar, capacity = 2200 liter O2

[email protected]

* Different international connection threads are available upon request.