Page 1: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

BY-PASS CONTROL VALVES REFERENCES

Page 2: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

1

PROJECT: CHINA CHONGQING 800 KT/A METHANOL

850,000 tonne/year natural gas-based methanol plant at Chongqing in southwest China

CUSTOMER: TENGLONG AROMATIC HYDROCARBON (ZHANGZHOU) CO. LTD

COUNTRY: CHINA

VALVE MODEL: PRDV – INLINE PRESS REDUCTION VALVE

The installed valves are forged F304H in-line pressure reduction valve, flow to close, single cage, balanced

through a pilot plug. This allows to have a valve suitable for intermittent service and closed for the most part

of its life. The bonnet is bolted design.

The valves are equipped with VALVITALIA Linear Piston Actuators, Spring Return, Fail close. The accessories

control panel is complete with SMART Positioner and pneumatic booster to achieve a valve opening time of

less than 3 seconds.

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H PRDV – INLINE

PRESS REDUCTION

VALVE

DN 250 ANSI 2500

DN 250 ANSI 2500

112 bar 550°C

30 bar

321.000

PROJECT COMPLETION: 6 MONTHS

YEAR 2010

Page 3: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

2

PROJECT: PX AND PTA CHEMICAL PLANT, THAILAND

CUSTOMER: TENGLONG AROMATIC HYDROCARBON (ZHANGZHOU) CO. LTD

COUNTRY: CHINA

VALVE MODEL: PRDV – ANGLE HHP BY-PASS, PRDV – ANGLE HP BY-PASS, PRDV – ANGLE IP BY-

PASS

The supplied Bypass Stations are

comprised of qty 3 Steam pressure

reduction and steam conditioning

systems.

The first HP Bypass system includes

qty 2 Bypass Valves angle type, size

10" #2500 x #900 BW in A182 F22. The

trim is Extra Low Noise type, complete

with pilot plug.

Downstream the valve seat, directly

mounted into the injection chamber,

there is a double stages silencer to

reduce the noise generated from the

valve trim before the water injection.

The injection chamber is full integrated downstream the valve seat and is provided with a wall mounted desuperheating system made

up of water spray nozzles (variable area, spring type).

The HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators, fail last, sized for a quick opening/closing time

of less than 5 seconds in trip mode.

The second HP Bypass system includes qty 1 Bypass valve angle type, 10x16" #2500 x #600 in A182 F22.

Provided with Low Noise trim and pilot plug, the Bypass valve is designed with integrated double stage silencer and 16” injection

chamber. The desuperheating section, wall mounted on the injection chamber, is provided with variable area-spring assisted water

spray nozzles.

The Valvitalia Pneumatic Double Acting actuator guarantees 5 seconds quick opening/closing time.

The supplied IP Bypass system is made up of qty 2 Bypass Valves angle type 12x14" #600 x #300 BW in A105.

The valve trim is Low noise type and the steam conditioning is realized through the water spray nozzles wall mounted in the integrated

injection chamber (14”).

The valve is provided with Valvitalia Pneumatic Diaphragm actuator, spring return, with fail position “last”.

PROJECT COMPLETION: 8 MONTHS

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H

PRDV – ANGLE HHP BY-PASS

DN 250 ANSI 2500

DN 250 ANSI 900

150 bar 550° C

98 bar 340° C

248.000

PRDV – ANGLE HP BY-PASS

DN 250 ANSI 2500

DN 400 ANSI 600

150 bar 550° C

45 bar 380° C

270.000

PRDV – ANGLE IP BY-PASS

DN 300 ANSI 600

DN 350 ANSI 300

50 bar 385° C

23 bar 230° C

182.000

YEAR 2011

Page 4: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

3

PROJECT: SALAMANCA GTO POWER PLANT 866 MW

The thermoelectric power plant in Salamanca, Guanajuato, in the Bajio Region of Mexico, which started

operation in 1971 and has an effective installed generation capacity of 866 megawatts (MW), is one of the

oldest CFE’s electricity generation facilities in operation.

CUSTOMER: IBERDROLA

COUNTRY: SPAIN END USER: CFE

COUNTRY: MEXICO

VALVE MODEL: PRDV – INLINE STATIONS

The valves supplied for this project are in-line qty 2 Turbine By-Pass Valves size 20" rating 900# in A182 F91

and qty 2 Turbine By-Pass Valves size 12", rating 300# in A216 WCC.

Both the Bypass systems are provided with integrated downstream injection chamber.

The desuperheating section is made up by spray water multiple nozzles, probe mounted.

ACTUATOR: PNEUMATIC DOUBLE ACTING CYLINDER, PNEUMATIC DIAPHRAGM ACTUATOR

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H

PRDV – INLINE STATIONS

DN 500 ANSI 900

DN 500 ANSI 900

71 bar 500° C

65 bar 480° C

580.000

PRDV – INLINE STATIONS

DN 300 ANSI 300

DN 350 ANSI 300

25 bar 300° C

20 bar 280° C

85.000

PROJECT COMPLETION: 7 MONTHS

YEAR 2011

Page 5: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

4

PROJECT: DEAD SEA WORKS POWER STATION - GAS TURBINE 1 (DSWPP-GT1)

A new gas-fired co-generation power plant consisting of a Gas Turbine, Heat Recovery Steam Generator

Boiler and a Steam Turbine. The new Power Plant has a capacity of 220 MWh ton per hour low pressure

steam. The power Plant is located inside the Dead Sea Works industrial site at Sdom.

CUSTOMER: ABEINSA

COUNTRY: SPAIN

END USER: DEAD SEA WORKS

COUNTRY: ISRAEL

VALVE MODEL: PRDV – ANGLE IP BY-PASS TO CONDENSER

The scope of supply for this project includes a Bypass Valve size 10"x16", rating 300# x 150#, material SA105.

The trim is flow to close, single cage, balanced through a pilot plug, suitable for intermittent service and seat

leakage class V.

Downstream the valve seat, directly mounted into the injection chamber, there is a double stages silencer

and an integrated 16” injection chamber, with probe mounted desuperhater (variable area spring type

nozzles)

The valve is provided with Valvitalia Pneumatic Diaphragm actuator, spring return, with fail position “closed”.

The High Performance SMART Actuator ensure fast acting in modulating and quick opening/closing mode.

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H

PRDV – ANGLE IP

BY-PASS TO

CONDENSER

DN 250

ANSI 300

DN 400

ANSI 150

19 bar

300° C

7 bar

180° C

60.000

PROJECT COMPLETION: 7 MONTHS

YEAR 2013

Page 6: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

5

PROJECT: PERMSKAYA POWER PLANT 2400 MW

Perm TPP is a major supplier of electricity to Ural and Volga Regions of Russia and one of the largest

thermal power stations in Europe. Perm TPP is fueled by natural gas from Urengoy and Yamburg gas fields

delivered via branches connected to main pipelines. Perm TPP delivers electricity to Ural Energy System

over 220 and 500 kV transmission lines.

CUSTOMER: EMALLIANCE

COUNTRY: RUSSIA

END USER: MINISTRY OF ENERGY

COUNTRY: RUSSIA

VALVE MODEL: PRDV – ANGLE IP STATIONS (and SYSTEM BACKPRESSURE)

The installed valves are in-line PRDS Globe valves with Extra Low Noise trim to reduce the noise generated

from the steam pressure reduction. The valves for the auxiliary service on boiler feedwater and continuous

blowdown complete the scope of Supply.

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H

PRDV – ANGLE IP STATIONS (and SYSTEM BACKPRESSURE)

DN 200 ANSI 2500

DN 300 ANSI 300

130 bar 566° C

32 bar 365° C

274.000

ACTUATOR: ELECTRIC FAST STROKE ACTUATOR (SHIEBEL)

PROJECT COMPLETION: 8 MONTHS

YEAR 2013

Page 7: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

6

PROJECT: SREDNEURALSKAYA POWER PLANT (DH) 1650 MW

Thermal station supplying electricity and heat to Yekaterinburg and a part of Sverdlovsk Oblast

CUSTOMER: ENEL SERVIZI S.r.l.

COUNTRY: RUSSIA

END USER: OGK-5

COUNTRY: RUSSIA

VALVE MODEL: PRDV – ANGLE

The valves installed in the project are qty 3 Bypass Angle type valves, 12"x24”, rating 600#, in A217 WC6.

The valves are provided with Extra Low Noise Cage and Downstream Single Stage Silencer.

The injection chamber is full integrated downstream the valve seat and is provided with a wall mounted

desuperheating system made up of water spray nozzles (variable area, spring type).

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE KG/H

PRDV – INLINE STATIONS

DN 300 ANSI 600

DN 600 ANSI 600

35 bar 425° C

9,5 bar 270° C

200.000

PRDV – INLINE STATIONS

DN 250 ANSI 600

DN 400 ANSI 600

28 bar 360° C

8,5 bar 270° C

70.000

ACTUATOR: ELECTRIC ACTUATOR (AUMA)

PROJECT COMPLETION: 6 MONTHS

YEAR 2013

Page 8: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

7

PROJECT: ASSALUYEH POWER PLANT, IRAN

Assaluyeh power plant is a gas turbine power plant capable of being extended into combined cycle. This

power plant comprised of six units each with 159 MW capacity which upon complition and operation,

about 1000 MW will be added to the electric power generation capacity of Assaluyeh.

CUSTOMER: BRUNO PRESEZZI – FRANCO TOSI MECCANICA

COUNTRY: ITALY

END USER: FARAB

COUNTRY: IRAN

VALVE MODEL: PRDV – ANGLE HP BY-PASS, PRDV – ANGLE LP BY-PASS

The supplied Bypass Stations are comprised of qty 12 Steam pressure reduction and steam conditioning

systems (qty 6 for HP Steam and qty 6 for LP Steam)

The HP Bypass valves are angle type, 12”x40”, 1500#x300#, made in A 182 F22 Cl.3 x A 182 F11 Cl.2.

Provided with Extra Low Noise trim and pilot plug, the Bypass valve is designed with integrated double stage

silencer and 40” injection chamber. The desuperheating water spray nozzles are wall mounted on the

injection chamber.

The Valvitalia Pneumatic Diaphragm actuator are designed for a quick closing action of 1 second.

The LP Bypass Stations are made up of 10”x16” 150# angle type valves, in A105, including 16” injection

chamber for steam desuperheating.

A Valvitalia Pneumatic Diaphragm actuator guarantees the quick closing action in 1 second.

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE

PRDV – ANGLE HP BY-PASS

DN 300 ANSI 1500

DN 1000 ANSI 300

90 bar 520° C

3 bar 137° C

250.000

PRDV – ANGLE LP BY-PASS

DN 250 ANSI 150

DN 400 ANSI 150

9 bar 235° C

1,8 bar 130° C

50.000

PROJECT COMPLETION: 7 MONTHS

YEAR 2015

Page 9: BY-PASS CONTROL VALVES REFERENCES - Valve …valve-tec.fi/data/documents/BY-PASS-REFERENCE-LIST.pdfThe HP Bypass valves are equipped with Valvitalia Pneumatic Double Acting actuators,

8

PROJECT: MAPNA-TUGA 10MW PROJECT

Iran Power Plant Projects Management Company (MAPNA) plans to build 8 mini combined cycle power

plants across the country

CUSTOMER: BRUNO PRESEZZI – FRANCO TOSI MECCANICA

COUNTRY: ITALY

END USER: MAPNA - TUGA

COUNTRY: IRAN

VALVE MODEL: PRDV – ANGLE HP BY-PASS

The valves in the scope of supply are qty 2 Bypass valve, angle type, size 6"x 16", rating ANSI 600# x 150#;

valve material is A217 WC6.

The steam pressure reduction valves are flow to close, single cage, balanced through a pilot plug. The

injection chamber is integral part of the Bypass valves, and the water spray nozzles are housed in a wall

mounted desuperheating water circuit.

The valves are equipped with Valvitalia Diaphragm actuators, with pneumatic circuit designed to ensure a

quick closing action in 1 second.

TECHNICAL REMARKS:

VALVE MODEL INLET OUTLET P1/T1 P2/T2 FLOWRATE

PRDV – ANGLE HP BY-PASS

DN 150 ANSI 600

DN 400 ANSI 300

40 bar 469,9° C

3 bar 137,8° C

34.500

PROJECT COMPLETION: 7 MONTHS

YEAR 2015