BWRVIP Mitigation Committee Meeting
Plant Experience Report
Name: Perry
Utility: FENOC Plant/Unit: 1
Cycle Number: 16
Meeting Date: June 3-17, 2016
Meeting Location: San Antonio, TX
Mitigation Performance – Cycle to Date
CY16 started April 2015.
Mitigation PI – Green for cycle.
Cycle
Apr
2015
May
2015
Jun
2015
Jul
2015
Aug
2015
Sep
2015
Oct
2015
Nov
2015
Dec
2015
Jan
2016
Feb
2016
Mar
2016
Apr
2016
May
2016
Mitigation
PIgreen yellow white green green green green green yellow green white green green green green
• April 2015 – cycle start.
• November 2015 – ECP Monitor hours > -350 SHE. MMS skid
unavailability due to temperature differential >5°F between MMS
and RWCU.
• January 2016 – HWC ramp test and Maintenance outage.
Inspection Relief Status
Claim inspection relief based on HWC
for jet pump hold down beams.
Increased inspection interval from every 6
years to every 10 years.
Next hold down beam inspection in 1R17
(2019).
Notable Chemistry Transients or Mitigation
Performance Issues
Replacement of Dresser
globe valves in FW
injection lines with gate
valves in 1R15.
Could not establish DI
water injection at 90
ml/min.
Attempted injection at
50% flows – skid tripped
on high pressure.
October 2015 application
terminated after injection
of 138 g Pt.
OLNC feedwater injection lines blocked after valve
replacements in 1R15 (2015).
Alternate OLNC Injection Point
Alternate injection point identified as ¾” vent line into RWCU on the return to vessel after regenerative heat exchangers.
Ties into both FW lines downstream of normal injection points.
OLNC skid moved into containment to refuel floor to inject.
◦ Contaminated area
◦ Containment FME zone
◦ Rigging through airlock to refuel floor
Alternate OLNC Injection Point
Temporary modification provided for:
◦ DI water source
◦ Power
◦ Seismic evaluation
◦ Transient combustible loading
Temporary procedures for injection
Containment FME logs
Skid Migration into Containment
Skid Migration into Containment
Skid Migration into Containment
OLNC Skid on Refuel Floor
DI Water
Temp Power
Seismic
restraints
Connection point to RWCU
1G33F0524 below grating
Reactor Plant
Sample Panel
1G33F0524
1G33F0524 1G33F0524
OLNC Skid Issues Encountered
Computer slow response
◦ Defragmented hard drive
DI water pump drive assembly seizure
◦ Last day of injection
◦ Purchased replacement drive assembly
◦ Purchased backup DI water pump
Pressure indicator PI-1 and PI-2 failure
◦ Displays strobe then go blank
◦ Capacitor issue on PI boards
◦ Purchased one new, will refurb two installed, and keep extra in spares
March 2016 OLNC Results
March 2016 OLNC Results
March 2016 OLNC Results
March 2016 OLNC Results
March 2016 OLNC Results
March 2016 OLNC Results
Other
Effectiveness of new resin strategies for
cobalt removal – CoSeq trials
◦ Slightly better efficiency for Co-60 over time
◦ Shortened run lengths
21-26 days CoSeq
28-35 days 2110H
◦ Precoat fails rapidly with little warning
◦ Resin intrusions seen using manufacturer-
recommended resin underlay
Rx Chem after RWCU CoSeq BW/PC
CoSeq CoSeq2110H 2110H
Cost Comparison
CoSeq on RWCU A (2 bag overlay) 2110H on RWCU A
backwash frequency 3 weeks backwash frequency 4 weeks
backwashes per year 17.3 backwashes/year 13
cost of CG19H underlay $75.96 /ft3 cost of 2110H resin $73.50 /ft3
cost of CoSeq $6,750.00 /ft3
bags underlay 4
bags CoSeq overlay 2 bags 2110H 6
resin cost per backwash $13,803.84 resin cost per backwash $441.00
resin cost per year $239,266.56 resin cost per year $5,733.00
RWCU backwashes/HIC 9 RWCU backwashes/HIC 9
cost of RWCU HIC for disposal $350,000.00 cost of RWCU HIC for disposal $350,000.00
# HICs generated from RWCU A 1.93 # HICs generated from RWCU A 1.44
cost for disposal of RWCU A resin $674,074.07 cost for disposal of RWCU A resin $505,555.56
Total Cost per backwash $52,692.73 Total Cost per backwash $39,329.89
Total Annual Cost $913,340.63 Total Annual Cost $511,288.56
Other
Low power H2 injection implemented
2013 (1R14)
◦ Placed in service ~4% power
◦ MFP or one RFP in service
◦ SJAE in service
◦ One Hydrogen Analyzer in service
EHWC – not currently planned.
Requested to reduce H2 injection to
reduce costs.
Other
Issues with Water Chemistry Strategic Plan or
BWRVIP-190 Revision implementation
◦ none
Questions/problems with BWRVIA/ECP model
results
◦ none
Any current or planned deviation
◦ none
Other
Artifacts for CNC or OLNC Pt
Characterization
Perry has two MMS coupons that have seen
1 and 2 OLNC applications which
correspond to the in-vessel artifact scraping
from a capsule which has also seen the same
two OLNC applications. Coupons at
NWT/GEH now for analysis.