butler wall

Upload: sectiune79

Post on 30-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 Butler Wall

    1/4

    L i nd a b B ut l er m e t a l b u i l d i n g s y s t e m s

    www.lindab-butler.com

    DUISBURG

    GmbH

    Anerkannte Ausbildungs-, Prf-, berwachungs-und Zertifizierungsstelle

    Akkredititerte Prflaboratorien

    Building SystemsButler

    Wall Systems

    Lindab Butler Building SystemsService CentreHBV-Hallen + Bausysteme VertriebFranz-Kissing Str. 7.58 706 Menden, Germany

    Tel: +49 2373 926 130Fax: +49 2373 926 133Mobile: +49 172 77 52 175

    Butler Building SystemsEvans Business CentreMitchelston Industrial EstateMitchelston DriveKirkcaldy Fife

    Scotland, KY1 3UFTel: +44 (0) 1592 652 300Fax: +44 (0) 1592 653 135

    Lindab Butler Building SystemsRepresentative OfficeInternational Trade CenterBd. Al. Vlahuta 10. office No. F8Brasov

    2200 RomaniaTel: +40 268 324 618Fax: +40 268 326 431

    Lindab Butler Building SystemsDerkovits u. 106-108.Nyregyhza4400 HungaryTel: +36 (42) 501 310Fax: +36 (42) 312 029

    Representative Office:Alkots u. 39/cBudapest

    1123 Hungar yTel: +36 (1) 489 46 70Fax: +36 (1) 489 46 80

    Lindab Butler Building Systemsul. Kolejowa 311, Sadowa05-092 omianki, PolandTel: +48 (22) 751 88 90Fax: +48 (22) 751 96 67

    Office in Pozna:ul. w. Michaa 4361-119 Pozna

    PolandTel: +48 (61) 650 36 86Fax: +48 (61) 650 36 89

    Lindab Sp. z o.o.

    Lindab Butler Building SystemsLindab s.r.o.

    251 01 Czech Republic

    Tel: +420 323 627 111Fax: +420 323 637 463

    Zdbradsk 56any

    Butler Building Systems

  • 8/14/2019 Butler Wall

    2/4

    L i nd a b Bu t le r m e t a l b u i l d i n g s y s t e m s

    LVP 20 Liner 1000

    LVP 45

    LVP 38 LVP 38R

    1035

    115 65 2518

    65

    21.5

    1000

    38

    333.387.3123 123 333.3

    32 73

    333.3

    1000

    32

    87.3 123123

    73

    333.3

    38

    900

    180 77 47

    43

    1035

    115 65 2518

    LVP 38RCombines architectural aesthetics with

    exceptional energy efficiencyLVP 38R is a 1000 mm wide factory roll-formed panel

    with four 38 mm high major corrugations. The distance

    between major corrugations is 333 mm. The flat of the

    panel contains two additional minor vee corrugations.The panelthickness is0.5 mmor 0.6mm andis available

    in polyester pre-painted steel or Top Coat, high built

    polyester pre-painted steel. See Colour Chart for colour

    selection. Panelsare fixed tothe structure by self drilling

    screws.Torx head

    LVP 45Architecturally pleasingappearanceLVP 45 is a 900 mm wide factory roll-formed panel with five 45 mm high major corrugations. The distance between

    major corrugations is 180 mm. The panel thickness is 0.5 mm or 0.6 mm and is available in polyester pre-painted

    steel orTop Coat,highbuilt polyesterpre-paintedsteel.See Colour Chartfor colourselection.

    Panelsarefixedtothestructureby selfdrilling screws.Torx head

    LVP 20LVP 20 isa 1035mm wide factory roll-formedpanelwithnine18mm high major corrugations.The distance between

    majorcorrugationsis 115mm. Thematerialis 0.4 mmthick white (RAL9010) polyesterpre-paintedsteel.

    For greater sound reduction LVP 20 is available in 0.5 mm thick, 35% perforated material, providing up to 25.5 dB

    airborne soundinhibitionwith100 mmfiberglassinsulation.

    LVP 20D(optional)

    Liner 1000Liner 1000 is a 1000 mm wide factory roll-formed panel with three 19 mm high major corrugations. The distance

    betweenmajor corrugationsis 333mm. Thematerialis 0.4mm thickwhite(RAL9010)polyesterpre-painted steel.

    333.3 333.3

    64 26

    121.1 91.1 121.1

    19

    1000

    LVP 38Economy, energy efficiency and quality in

    every detailLVP 38 isa 1000 mmwidefactoryroll-formed panelwith

    four 38 mm high major corrugations. The distance

    between major corrugations is 333 mm. The flat of the

    panel contains two additional minor vee corrugations.The panelthicknessis 0.5mm or0.6 mmandis available

    in polyester pre-painted steel or Top Coat, high built

    polyester pre-painted steel. See Colour Chart for colour

    selection. Panelsare fixed tothe structureby self drilling

    Torxhead screws.

  • 8/14/2019 Butler Wall

    3/4

    L i nd a b B ut l er m e t a l b u i l d i n g s y s t e m s

    INSULATION

    UP TO 200 mm

    EXTERIOR

    PANEL

    TORX HEAD

    SCREWINTERIOR PANEL

    INSULATION

    BRIDGE

    FACED INSULATION

    UP TO 200 mm

    TORX HEAD

    SCREW

    EXTERIOR

    PANEL

    INSULATION

    BRIDGE

    INTERIORPANEL

    Liner panels installed on the inside of the girts creates a

    clean interior appearance. Liner options include LVP 20

    and Liner 1000.

    LVP 38, LVP 38R, LVP 45 or LVP 20 with liner panels

    installed on the outside of the girts. Liner options include

    LVP 20 and Liner 1000.

    Insulation (mm) 80 100 120 200

    U values (W/m K) 0.47 0.38 0.32 0.192

    Insulation (mm) 100 120 200U value ( 0.4 0.33 0.21W/m K)

    2

    Insulation 100 120 200

    U value 0.4 0.33 0.21

    (mm)

    (W/m K)2

    INSULATION

    BRIDGE

    TORXHEADSCREW

    ZED SPACER

    MINERAL WOOL OR

    FIBREGLASS INSULATION

    PLASTIC

    FERRULE

    EXTERIORPANEL

    Insulation 100 120

    U value 0.45 0.4

    (mm)

    (W/m K)2

    FACED INSULATION

    UP TO 200 mm

    TORX HEAD

    SCREW

    EXTERIOR

    PANEL

    FACED INSULATION

    80 mm

    TORX HEAD

    SCREW

    EXTERIOR

    PANEL

    U value = 0.63 W/m K2

    Exterior corner detail.Interior corner detail.

    Lindab Butler Wall Systems provide a variety of attractive, economical and energy efficient options for both

    the exterior and interior of your building.

    LVP 38, LVP 38R, LVP 45 and LVP 20 Wall Systems.

    Engineered to be energy efficient and economical to install and maintain.

    Fire rated wall system: Certified by Warrington Resource

    Centre (UK), Test result 300 minutes in accordance with

    BS 476.

    Lindab Butlers' insulation details comply with the most

    stringent building regulations in Europe.

  • 8/14/2019 Butler Wall