busbar chamber system

7
Busbar Chamber System Havells BUSBAR CHAMBER system is designed or sa e, reliable & economical distribution o power to various loads as per the requirements o the system.  The modular construction o the bus bar chamber provides or compact & easy add-on modules on the basic unit or system expansion (i the need be). These can be wall mounted and can also be made suitable or foor mounting by using optional pedestal set. Features: Read ymade &cu stomis edso lution forsa fepowerdi stridu tion Modular/compact design pro vides econo myof space and cost Simple and efc ients ystemcon guratio n Easy ,exible andt imesa vingin stallation Shock pr oof design Elegan t&sl eek inappearance Range :  The busbarchambers areavailable for 100A/200A, 250A/315A/400 A & 630A/800Acurrent ratingswith shortcircuitwithstandcapacityof25kA,35kA&50kA respectively.Theseareofferedin4way,6way&8way inFourPoleconguration. Specifcation : Fully application oriented as per IS:8623/IEC60439(Panelsubassemblies) IS:2147/IEC60529(Degreeforprotection)

Upload: bmsingh

Post on 07-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 1/6

Busbar Chamber System

Havells BUSBAR CHAMBER system is

designed or sae, reliable & economical

distribution o power to various loads

as per the requirements o the system.

 The modular construction o the bus

bar chamber provides or compact

& easy add-on modules on the basic

unit or system expansion (i the need

be). These can be wall mounted and

can also be made suitable or foor

mounting by using optional pedestal

set.

Features:• Readymade&customisedsolutionforsafepowerdistridution

• Modular/compactdesignprovideseconomyofspaceandcost

• Simpleandefcientsystemconguration

• Easy,exibleandtimesavinginstallation

• Shockproofdesign

• Elegant&sleekinappearance

Range : Thebusbarchambersareavailable for 100A/200A,

250A/315A/400A&630A/800Acurrent ratingswith

shortcircuitwithstandcapacityof25kA,35kA&50kA

respectively.Theseareofferedin4way,6way&8way

inFourPoleconguration.

Specifcation :Fully application oriented as per

IS:8623/IEC60439(Panelsubassemblies)

IS:2147/IEC60529(Degreeforprotection)

Page 2: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 2/6

 Application : Thebusbarchambersndwideapplicationinpowerdistributioninareasnamely:

• Constructionsite

• Shopoor

• Multi-storeyedcomplexes

• Buildinginstallationetc.

Page 3: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 3/6

212

Construction

 Thebusbarchamber is fabricatedusing sheet steel (CRCA) of 1.6mm thicknessand epoxy

powdercoatedtogivesuperior&lastingnish.ThebusbarsectionsaremadeofETPgrade

copper&dulltinplatedandthebusbarsupportsaremadeofDMC(Doughmouldingcompound).

 The neutral bus bar is ully rated.

Inbusbarchambersupto200A,thebusbarlayoutisinasinglelayer(i.e.onebythesideof

theother&dulyseparated/supportedonthebusbarsupport).Whereasinbusbarchambersof

250A/315A/400A/630A/800A,thebusbarlayoutisinformofstack(i.e.onebusbarbehind

theotherdulyseparated/supportedbybusbarsupport).Allhavedetachableendplatesenabling

them to be extended easily with the connection o another chamber. Full top and bottom end

plates are detachable.

Kitcomprisingofconnectingcopperlinksareavailableforextendingthebusbarsectioninthe

add on module.

100A / 200A 250A / 800A

Technical Inormation

Frame 200A 400A 800A

StandardConformity IEC-60439/IS-8623 IEC-60439/IS-8623 IEC-60439/IS-8623 

IEC-60529/IS-2147 IEC-60529/IS-2147 IEC-60529/IS-2147

IncomingCurrentRating(A) 100,200 250,315,400 630,800

OperationalVoltage-Frequency(V/Hz) 415-440/50 415-440/50 415-440/50

Insulation Voltage (V) 1000 1000 1000

Execution (No. of Poles) FP FP FP

ShortCircuitwithstandCapacity(1Sec.,KA) 25 35 50

Outgoing(No.ofWays) 4.6,8 4,6,8 4,6,8

DegreeofProtection IP-31 IP-31 IP-31

BusbarLayout Singlelayer(sidebyside) Stacklayer(onebehindtheother)

Page 4: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 4/6

213

Ordering Inormation

Front Connection

Current Rating No. of Cat. No.

ways Wall Mounted

100A 4way IHBB010004 

6way IHBB010006 

8way IHBB010008

200A 4way IHBB020004 

6way IHBB020006 

8way IHBB020008

250A 4way IHBB025004 

6way IHBB025006 

8way IHBB025008

315A 4way IHBB031504 

6way IHBB031506 

8way IHBB031508

400A 4way IHBB040004 

6way IHBB040006 

8way IHBB040008

630A 4way IHBB063004 

6way IHBB063006 

8way IHBB063008

800A 4way IHBB080004 

6way IHBB080006 

8way IHBB080008

*Accessories-connectingcopperlinkstoextendthebusbarsectionintheadd-onmodule.

Dimension (mm) Frame - 200A

No. of Ways Dimn. ‘A’ Dimn. ‘B’

4WayTPN 450 360

6WayTPN 630 540

8WayTPN 810 720

Page 5: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 5/6

214

Dimension (mm) Frame - 400A / 800A

Busbar Chamber - Main - 400A & O / G - 200A

No. of Ways Dimn. ‘A’ Dimn. ‘B’

4WayTPN 700 600

6WayTPN 950 850

8WayTPN 1200 1100

Page 6: Busbar Chamber System

8/3/2019 Busbar Chamber System

http://slidepdf.com/reader/full/busbar-chamber-system 6/6

215

Illustration

*Supply o Busbar Chamber is in our scope, the mounting shown are or illustration purpose only.