burnside enterprises, llc - colorado springs
TRANSCRIPT
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 1 of 9
Burnside Enterprises, LLC
4030 Zurich Drive
Colorado Springs, CO 80920
Phone: 719-596-4656
Website: www.LeadPaintColorado.com
Email: [email protected]
LIMITED ASBESTOS BUILDING INSPECTION
Prepared for : City of Colorado Springs
Housing Development Division
30 S Nevada Ave, Suite 604
Colorado Springs, CO 80903
Rosemary Dominguez
1165 W Nolte Dr
Colorado Springs, CO 80916
Property Address:
1165 W Nolte Dr
Colorado Springs, CO 80916
Inspection performed by:
John Burnside
Colorado Asbestos Building Inspector # 21520
Burnside Enterprises, LLC
Asbestos Consulting Firm license # ACF-21529
Inspection performed on June 2, 2015
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 2 of 9
TABLE OF CONTENTS
I Introduction & Summary
II Building Inventory
III Bulk Sampling Procedures and Location Selection
1. Determination of sampling location
2. Bulk sample analysis
IV Quantities of Asbestos Containing Material to be disturbed
1. Single family residential dwellings
2. All other areas that are not single family dwellings
ATTACHMENTS
A. Bulk Sample Log
B. Sketch
C. Lab Reports & Chain of Custody
D. Certifications
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 3 of 9
SECTION I. INTRODUCTION & SUMMARY
On June 2, 2015 Burnside Enterprises, LLC performed a limited asbestos building inspection on
the single-family residence located at 1165 W Nolte Dr, Colorado Springs, CO 80916. The
purpose of the inspection was to determine if Asbestos Containing Material (ACM) would be
disturbed/impacted during a planned renovation of the property. The area inspected for ACM
included the drywall & flooring surfaces. No other areas were inspected. Burnside Enterprises,
LLC utilized the scope provided by Paul Morrow with the City of Colorado Springs to develop a
sampling scheme that would include any possible ACM materials in the area disturbed in the
planned renovation.
John Burnside of Burnside Enterprises, LLC performed the asbestos building inspection.
Individual and firm certifications can be found in Attachment E.
The following table summarizes the sampled materials and how each tested for ACM:
Sample
No.
Description Location Friable/
Non-friable
%
Asbestos
Amount
of
Material
DW-01 Drywall Compound Bsmt Room 03 Friable ND 0% 900 sf
DW-02 Drywall Compound Bsmt Room 04 Friable ND 0%
DW-03 Drywall Compound Bsmt Room 05 Friable ND 0%
DW-04 Drywall Compound Ground Room 07 Friable ND 0% 900 sf
DW-05 Drywall Compound Ground Room 13 Friable ND 0%
DW-06 Drywall Compound Ground Room 08 Friable ND 0%
M-01 Flooring White Bsmt Room 04 Non-friable ND 0% 50 sf
M-02 Flooring adhesive exposed
on concrete
Bsmt Room 04 Friable ND 0% Unknown
M-03 Flooring Bsmt Room 03 Friable ND 0% 50 sf
CLG-01 Ceiling texture Room 07 Friable ND 0% 500 sf
CLG-02 Ceiling texture Room 08 Friable ND 0%
CLG-03 Ceiling texture Room 09 Friable ND 0%
CH – Chrysotile AM – Amosite Asbestos CR – Crocidolite ND – None Detected
SECTION II BUILDING INVENTORY
The property located at 1165 W Nolte Dr, Colorado Springs, CO 80916 is approximately 1000
SF and constructed in 1977. The structure is frame construction and has a forced air HVAC
system. The structure is in overall good condition. The specific area tested for the presence of
ACM includes the drywall & flooring surfaces. A sketch of the building floor plan is included in
Attachment B.
SECTON III BULK SAMPLING PROCEDURES AND LOCATION SELECTION
1. Determining Sampling Locations
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 4 of 9
Locations were selected for representative materials that will or may likely be disturbed by the
planned renovation. The EPA divides suspect ACM into three categories as follows:
Surfacing Material means material that is sprayed on, troweled on, or otherwise applied to
surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members,
or other materials on surfaces for acoustical, fireproofing, or other purposes.
Thermal System Insulation (TSI) means material applied to pipes, fittings, boilers, breeching,
tanks, ducts, or other interior structural components to prevent heat loss or gain, or water
condensation, or for other purposes.
Miscellaneous Material means interior building material on structural components, structural
members or fixtures, such as floor and ceiling tiles, and does not include surfacing material or
thermal system insulation.
Any samples taken at the site were categorized into one of these three categories. Representative
samples were taken from any of these groups of materials that might be impacted by the planned
renovation.
2. A total of 12 bulk samples were collected for this project. Samples were taken from
representative materials that are anticipated to be disturbed during the upcoming renovation
project. These samples were taken on June 2, 2015 and sent to an accredited lab for ACM
analysis.
IV QUANTITIES OF ASBESTOS CONTAINING MATERIAL TO BE DISTURBED
Prior to any renovation or demolition which may disturb greater than the trigger levels of
material identified as a suspect asbestos-containing material pursuant to the EPA "Green Book",
Managing Asbestos in Place, Appendix G (1990), the facility component(s) to be affected by the
renovation or demolition shall be inspected to determine if abatement is required.
Trigger levels means amounts of material as follows:
1. With regard to single-family residential dwellings, the trigger levels are 50 linear feet on
pipes, 32 square feet on other surfaces, or the volume equivalent of a 55-gallon drum.
2. With regard to all areas other than single-family residential dwellings, the trigger levels are
260 linear feet on pipes, 160 square feet on other surfaces, or the volume equivalent of a 55-
gallon drum.
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 5 of 9
Attachment A - Bulk Sample Log
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 6 of 9
Attachment B - Sketch
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 7 of 9
Attachment C - Lab Reports & Chain of Custody
EMSL Analytical, Inc.1010 Yuma Street, Denver, CO 80204Phone/Fax: (303) 740-5700 / (303) 741-1400http://www.EMSL.com [email protected]
221503106CustomerID: BURN34CustomerPO:ProjectID:
EMSL Order:
Attn: John BurnsideBurnside Enterprises4030 Zurich Dr.Colorado Springs, CO 80920
Received: 06/03/15 8:30 AM
1165 W Nolte, Colo Spgs
Fax: (719) 596-4656Phone: (719) 596-4656
Project:
6/4/2015Analysis Date:6/2/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
DW-01-Texture
221503106-0001
Drywall Compound White None Detected
HA: 1
Non-FibrousHomogeneous
Non-fibrous (other)100%
DW-01-Tape
221503106-0001A
Drywall Compound White None Detected
HA: 1
FibrousHomogeneous
Cellulose95% Non-fibrous (other)5%
DW-01-Joint Compound221503106-0001B
Drywall Compound White None Detected
HA: 1
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
DW-02
221503106-0002
Drywall Compound White None Detected
HA: 1
Non-FibrousHomogeneous
Non-fibrous (other)100%
DW-03-Texture
221503106-0003
Drywall Compound White None Detected
HA: 1
Non-FibrousHomogeneous
Non-fibrous (other)100%
DW-03-Drywall
221503106-0003A
Drywall Compound Brown/White None Detected
HA: 1
FibrousHomogeneous
Cellulose10% Gypsum50%Non-fibrous (other)40%
DW-04
221503106-0004
Drywall Compound White None Detected
HA: 2
Non-FibrousHomogeneous
Non-fibrous (other)100%
1Test Report PLM-7.28.9 Printed: 6/4/2015 8:52:00 AM
Barbara Shepherd, Laboratory Manageror other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 06/04/2015 08:52:00
Patricia Wood (19)
EMSL Analytical, Inc.1010 Yuma Street, Denver, CO 80204Phone/Fax: (303) 740-5700 / (303) 741-1400http://www.EMSL.com [email protected]
221503106CustomerID: BURN34CustomerPO:ProjectID:
EMSL Order:
Attn: John BurnsideBurnside Enterprises4030 Zurich Dr.Colorado Springs, CO 80920
Received: 06/03/15 8:30 AM
1165 W Nolte, Colo Spgs
Fax: (719) 596-4656Phone: (719) 596-4656
Project:
6/4/2015Analysis Date:6/2/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
DW-05
221503106-0005
Drywall Compound White None Detected
HA: 2
Non-FibrousHomogeneous
Non-fibrous (other)100%
DW-06-Texture
221503106-0006
Drywall Compound White None Detected
HA: 2
Non-FibrousHomogeneous
Non-fibrous (other)100%
DW-06-Tape
221503106-0006A
Drywall Compound White None Detected
HA: 2
FibrousHomogeneous
Cellulose95% Non-fibrous (other)5%
DW-06-Joint Compound221503106-0006B
Drywall Compound White None Detected
HA: 2
Non-Fibrous
Homogeneous
Non-fibrous (other)100%
M-01-Floor Tile
221503106-0007
Flooring White None DetectedNon-FibrousHomogeneous
Non-fibrous (other)100%
M-01-Mastic
221503106-0007A
Flooring Clear None DetectedNon-FibrousHomogeneous
Non-fibrous (other)100%
M-02
221503106-0008
Adhesive Yellow None DetectedNon-FibrousHomogeneous
Non-fibrous (other)100%
2Test Report PLM-7.28.9 Printed: 6/4/2015 8:52:00 AM
Barbara Shepherd, Laboratory Manageror other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 06/04/2015 08:52:00
Patricia Wood (19)
EMSL Analytical, Inc.1010 Yuma Street, Denver, CO 80204Phone/Fax: (303) 740-5700 / (303) 741-1400http://www.EMSL.com [email protected]
221503106CustomerID: BURN34CustomerPO:ProjectID:
EMSL Order:
Attn: John BurnsideBurnside Enterprises4030 Zurich Dr.Colorado Springs, CO 80920
Received: 06/03/15 8:30 AM
1165 W Nolte, Colo Spgs
Fax: (719) 596-4656Phone: (719) 596-4656
Project:
6/4/2015Analysis Date:6/2/2015Collected:
Sample Description Appearance % Type
AsbestosNon-Asbestos
% Fibrous % Non-Fibrous
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
M-03-Linoleum
221503106-0009
Flooring Gray/Tan None DetectedNon-FibrousHomogeneous
Non-fibrous (other)100%
M-03-Adhesive
221503106-0009A
Flooring Clear None DetectedNon-FibrousHomogeneous
Non-fibrous (other)100%
CLG-01
221503106-0010
Ceiling Texture White None Detected
HA: 3
FibrousHomogeneous
Cellulose10% Non-fibrous (other)90%
CLG-02
221503106-0011
Ceiling Texture White None Detected
HA: 3
FibrousHomogeneous
Cellulose15% Non-fibrous (other)85%
CLG-03
221503106-0012
Ceiling Texture White None Detected
HA: 3
FibrousHomogeneous
Cellulose15% Non-fibrous (other)85%
3THIS IS THE LAST PAGE OF THE REPORT.Test Report PLM-7.28.9 Printed: 6/4/2015 8:52:00 AM
Barbara Shepherd, Laboratory Manageror other approved signatory
Analyst(s)
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%Samples analyzed by EMSL Analytical, Inc. Denver, CO NVLAP Lab Code 200828-0
Initial report from 06/04/2015 08:52:00
Patricia Wood (19)
OrderID: 221503106
Page 1 Of 2
OrderID: 221503106
Page 2 Of 2
1165 W Nolte Dr, Colorado Springs, CO 80916 Page 8 of 9
Attachment D - Certifications