built-in series stainless flush inset installation
TRANSCRIPT
D E S I G N G U I D E
B U I L T- I N S E R I E SS T A I N L E S S F L U S H I N S E T I N S T A L L A T I O N
E F F E C T I V E 1 / 9 / 2 0 1 7
Features and specifications are subject to change at any time without notice. Visit subzerowolf.com.au for the most up-to-date information.
BUILT-IN REFRIGERATION
Built-In Refrigeration
Sub-Zero designers and engineers continue to perfect the built-in line. The addition of LED lighting throughout and several new models with internal water dispensers, along with the same advanced food preservation technology Sub-Zero is known for, make the built-in line nothing short of revolutionary.
BUILT-IN MODELS
ICBBI-36R ICBBI-36F ICBBI-36UID ICBBI-36UFDID
ICBBI-36S ICBBI-42S ICBBI-42SD ICBBI-48S ICBBI-48SID ICBBI-48SD
ICBBI-42UFDID
subzero-wolf.com.au
Built-In Refrigeration 3
Built-In Refrigeration 4
914 mm
2134mm
610 mm
102 mm
1873mm
606mm
946mm
432mm
606 mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
MODELS ICBBI-36R AND ICBBI-36F
Interior Capacity R (L) F (L)ALL REFRIGERATOR / ALL FREEZER MODELS ICBBI-36R 662
ICBBI-36F 640OVER-AND-UNDER MODELS ICBBI-30U 362 116 ICBBI-36U 451 149 SIDE-BY-SIDE MODELS ICBBI-36S 346 227 ICBBI-42S 455 227 ICBBI-42SD 453 230 ICBBI-48S 533 270 ICBBI-48SD 531 274
Shipping Weight kgALL REFRIGERATOR / ALL FREEZER MODELS ICBBI-36R 191 ICBBI-36F 184OVER-AND-UNDER MODELS ICBBI-30U 210 ICBBI-36U 234 SIDE-BY-SIDE MODELS ICBBI-36S 244 ICBBI-42S 264 ICBBI-42SD 276 ICBBI-48S 286 ICBBI-48SD 298
Shipping weights and overall dimensions are based on stainless steel models. For flush inset applications, add 13 mm to door clearance dimensions.
All Refrigerator / All Freezer ModelsOVERALL DIMENSIONS
Built-In ModelsSPECIFICATIONS
Built-In Refrigeration 5
762 mm
2134mm
610 mm
102 mm
1289mm
584mm
606mm
600mm 796
mm
368mm
606 mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
MODEL ICBBI-30U
914 mm
2134mm
610 mm
102 mm
1289mm
584mm
606mm
600mm 946
mm
432mm
606 mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
MODEL ICBBI-36UID
Over-and-Under ModelsOVERALL DIMENSIONS
subzero-wolf.com.au
Model ICBBI-36UFDID.
914 mm
2134mm
102 mm
1289mm
584mm
606mm
600mm
495mm
203mm
606 mmHEIGHT DIMENSIONS ± 13 mm
60 mm
665 mm
Overall Dimensions
OVER-AND-UNDER
Model ICBBI-42UFDID.
1067 mm
2134mm
102 mm
1289mm
584mm
606mm
565mm
229mm
606 mmHEIGHT DIMENSIONS ± 13 mm
60 mm
665 mm
600mm
Built-In Refrigeration 6
Built-In Refrigeration
Overall dimensions are based on stainless steel models. For flush inset applications, add 13 mm to door clearance dimensions.
1067 mm
2134mm
610 mm
102 mm
1873mm
606 mm
606mm
668mm
318mm
222mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
MODELS ICBBI-42S AND ICBBI-42SD
914 mm
2134mm
610 mm
102 mm
1873mm
606mm
565mm
216mm
260mm
606 mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
MODEL ICBBI-36S
Side-by-Side ModelsOVERALL DIMENSIONS
7
Built-In Refrigeration
1219 mm
2134mm
610 mm
102 mm
1873mm
606 mm
606mm
762mm
356mm
248mm
60 mm
HEIGHT DIMENSIONS ± 13 mm
Side-by-Side ModelsOVERALL DIMENSIONS
MODELS ICBBI-48S, ICBBI-48SD & ICBBI-48SID
8
Built-In Refrigeration
Electrical Requirements
Power Supply 220-240 V AC, 50/60 HzCircuit Breaker 10 ampReceptacle 3-prong grounding-type
Plumbing Requirements
Water Supply Line 6mm plastic lineWater Pressure 2.1–6.9 barWater line for Connection 5m
FRONT VIEW
1918 mmFROMFLOOR
178mm E
152mm
Freestanding location of power supply.
Built in. Alternative location of power & water supply depending on ease of access.
2,200 mmminimum
FROMFLOOR
1.
2.
2. Built in. Water supply besidefridge. Location of 6mmfl exible hose. Tape to wall andfl oor with pressure limitingvalve next to tap.
pressurelimiting valve
6mm flexi hose& tape to wall
& floor.
1.
2.
pressurelimiting valve
6mm flexi hose& tape to wall
& floor.
1. Built in. Water supply abovefridge. Location of 6mmfl exible hose. Tape to wall andfl oor with pressure limitingvalve next to tap.
pressurelimiting valve
6mm flexi hose& tape to wall
& floor.
1.
2.
pressurelimiting valve
6mm flexi hose& tape to wall
& floor.
Planning InformationELECTRICAL REQUIREMENTS
International models from the factory designed without a transformer require a 220-240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. If required by local or national codes, the power cord can be easily replaced using the power inlet device.
Built-in models should have the electrical supply either in the cabinet above the refrigerator a MINIMUM OF 2200MM ABOVE THE FLOOR or in the cabinet alongside. If freestanding then locate the power point as per the diagram below. A separate circuit servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
PLUMBING REQUIREMENTS
For built-in models with an automatic ice maker, a pressure limiting valve and 5 meters of fl exible 6mm pipe with fi ttings is included in the refrigerator carton. Connect the pressure limiting valve close to the water tap, CHECKING THE WATER FLOW IS IN THE RIGHT DIRECTION. Ensure water connection is ½” BSP male threaded outlet. Tape the 6mm water line to the wall and fl oor to ensure it isn’t squashed when the refrigerator is pushed into the cavity. Locate the water tap either in the cabinet above a minimum of 2200mm from the fl oor, or in the cabinet alongside. The water line must not interfere with installation of the anti-tip brackets.
IMPORTANT NOTE: A reverse osmosis system can be used provided there is constant water pressure of 2.1 bar to 6.9 bar supplied to the unit at all times.
9
Built-In Refrigeration
Stainless Flush Inset ApplicationIt is necessary to consider the following points when planning for a fl ush inset application:
• The fl ush inset depth is 56 mm deeper than thestandard opening depth.
• The fl ush inset width is 46 mm wider than thestandard opening width.
• The fl ush inset height is 22 mm higher than thestandard opening height.
• You must allow a 15 mm reveal around the perimeterof the unit and grille to allow for proper door swing andairfl ow.
IMPORTANT NOTE: The fl ush inset application is not a separate model. The same model is used in a standard or fl ush inset application of stainless steel fridge.
STANDARD INSTALLATION
620 mmminimumOPENING
DEPTH
675 mmminimum
FLUSHINSETDEPTH
56 mm 32 mm
TOP VIEWTOP VIEW
FLUSH INSET INSTALLATIONWITH 19 mm PANEL
620 mmminimumOPENING
DEPTH
Standard installation. Flush inset installation.
STANDARD INSTALLATION
620 mmminimumOPENING
DEPTH
675 mmminimum
FLUSHINSETDEPTH
56 mm 23 mm
TOP VIEWTOP VIEW
STAINLESS STEELFLUSH INSET INSTALLATION
620 mmminimumOPENING
DEPTH
10
Flush Inset Opening Widths A B
902 mm 948 mm902 mm 948 mm
1054 mm 1100 mm1252 mm
DETAIL A
DETAIL B
FRONT VIEW
AWIDTH TO CLEAT
BFLUSH INSET WIDTH
23mm
23mm
SIDE VIEW
2149mm
FLUSHINSET
HEIGHT
18 mm
620 mmminimum
DEPTH TO CLEAT
675 mmminimum
FLUSH INSET DEPTH
56mm
2127mm
HEIGHTTO CLEAT
620 mmminimum
DEPTHTO CLEAT
675mmminimum
FLUSHINSETDEPTH
TOP VIEW
56 mm
23mm CLEAT
CLEAT
Detail A
Detail B
23 mm
620 mmminimumOPENING
DEPTHTO CLEAT
CLEAT
TOP VIEW675mm
minimumFLUSHINSETDEPTH
56 mm
620 mmminimumOPENINGDEPTH TO
CLEAT
23 mm
56 mm
CLEAT
SHADEDAREA
MUST BEFINISHED
76 mmtypical
102mm
76 mmtypical
23 mm
620 mmminimumOPENING
DEPTHTO CLEAT
CLEAT
TOP VIEW675mm
minimumFLUSHINSETDEPTH
56 mm
620 mmminimumOPENINGDEPTH TO
CLEAT
23 mm
56 mm
CLEAT
SHADEDAREA
MUST BEFINISHED
76 mmtypical
102mm
76 mmtypical
Built-In ModelsFLUSH INSET INSTALLATION
Built-In Refrigeration
ICBBI-36R, ICBBI-36F
ICBBI-36UID, ICBBI-36UFDID, ICBBI-36S
ICBBI-42UFDID, ICBBI-42S, ICBBI-42SD
1206 mmICBBI-48S, ICBBI-48SID, ICBBI-48SD
11
749 mm 795 mmICBBW-30
Built-In Refrigeration
Dual InstallationSTAINLESS FLUSH INSET APPLICATION
Installing two built-in models side by side in a stainless fl ush inset application will require adjustments to the dimensions of your fi nished rough opening. It will also require a dual installation kit, avail able through your authorized Sub-Zero dealer.
* Dual installations without a fi ller strip can only be accom-plished using two units with opposite hinges as shownin illustration A below. The dual installations shown inillustrations B and C require a fi ller strip. Illustration Ais the only application that will accommodate the dualwide grille.
Illus. A
FILLER STRIP REQUIREDWITHOUT FILLER STRIP
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED
FILLER STRIP REQUIRED FILLER STRIP REQUIRED
FILLER STRIP REQUIREDWITHOUT FILLER STRIP
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED
FILLER STRIP REQUIRED FILLER STRIP REQUIRED
FILLER STRIP REQUIREDWITHOUT FILLER STRIP
WITHOUT FILLER STRIP
FILLER STRIP REQUIRED
FILLER STRIP REQUIRED FILLER STRIP REQUIRED
Illus. B Illus. C
12
Opening Widths A BTwo 762 mm Models 1518 mm 1564 mm762 mm and 914 mm Models 1670 mm 1716 mmTwo 914 mm Models 1822 mm 1868 mm
620 mmminimum
DEPTHTO CLEAT
675mm
minimumFLUSHINSETDEPTH
FRONT VIEW
TOP VIEW
56 mm
AWIDTH TO CLEAT
BFLUSH INSET WIDTH
23mm
23mm
SIDE VIEW
2149mm
FLUSHINSET
HEIGHT
18 mm
620 mmminimum
DEPTH TO CLEAT
675 mmminimum
FLUSH INSET DEPTH
56mm
2127mm
HEIGHTTO CLEAT
CLEAT
DETAIL A
DETAIL B
23 mmCLEAT
Detail A
Detail B
23 mm
620 mmminimumOPENING
DEPTHTO CLEAT
CLEAT
TOP VIEW675mm
minimumFLUSHINSETDEPTH
56 mm
620 mmminimumOPENINGDEPTH TO
CLEAT
23 mm
56 mm
CLEAT
SHADEDAREA
MUST BEFINISHED
76 mmtypical
102mm
76 mmtypical
23 mm
620 mmminimumOPENING
DEPTHTO CLEAT
CLEAT
TOP VIEW675mm
minimumFLUSHINSETDEPTH
56 mm
620 mmminimumOPENINGDEPTH TO
CLEAT
23 mm
56 mm
CLEAT
SHADEDAREA
MUST BEFINISHED
76 mmtypical
102mm
76 mmtypical
Dual InstallationSTAINLESS FLUSH INSET INSTALLATION
Built-In Refrigeration 13
Sub-Zero International Limited Warranty
FOR RESIDENTIAL USE
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, any part of the product that proves to be defec-tive in materials or workmanship. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Service will be provided during normal business hours.
FULL FIVE YEAR SEALED SYSTEM WARRANTY
For five years from the date of original installation, this Sub-Zero product warranty covers all parts and labor to repair or replace, under normal residential use, these parts that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Service will be provided during normal business hours.
For more information regarding your Sub-Zero product warranty, contact your authorized Sub-Zero dealer. Warranties must comply to all country, state, city, local and or ordinance.
*Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited60-day parts and labor warranty for cosmetic defects.
*Replacement water filters and air purification cartridges are not covered by the product warranty.
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design, are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries. All other trademarks are property of their respective owners in the United States and other countries.
S U B Z E R O - W O L F . C O M . A U
Bank House, 11 – 19 Bank Place.
Melbourne Victoria Australia 3000
Telephone 03 9600 2218