building wire 7-07-08
TRANSCRIPT
Building Wires & Interior Wires
An ISO 9001, ISO 14001 and OHSAS 18001 Certified Company
Phelps Dodge International (Thailand) Limited
Milestones 1968 EstablishedPhelpsDodgeThailandLimited
StartedproductionattheSamrongplant.
1992 StartedproductionattheBangpleeplant.
1993 Beganoperatingthestate-of-the-artVCVLine,toproduceExtraHighVoltagePowerCableforupto230kV.
1995 ObtainedtheISO9001fromBritishApprovals
ServiceforCables(BASEC)-firstinThailand.
1997 ObtainedanadditionalISO9001certificatefromtheThaiIndustrialStandardsInstitute.
1999 AchievedtheISO14001fromBritishApprovals
ServiceforCables(BASEC)
1999 StartedoperatingtheRayongBuildingWirePlant,andachievedISO9002fromUnderwritersLaboratoriesInc.(UL)
2000 TransferedtheISO9001andISO14001registrationsfromBritishApprovalsServiceforCables(BASEC)toUnderwritersLaboratoriesInc.(UL)
TransferedtheISO9001registrationfromThaiIndustrialStandardsInstitute(TISI)toManagementSystemCertification(Thailand)(MASCI)
2001 TheBangpleeplantobtaineditsOHSAS18001certificatefromUnderwritersLaboratories.(UL)
2002 TheBangpleeandRayongplantsobtainedISO9001Version2000fromUnderwritersLaboratories(UL)andManagementSystemCertification(Thailand)(MASCI)
2003 TheRayongplantobtaineditsISO14001andOHSAS18001certificatefromUnderwriterLaboratories(UL)
2005 Wonthe2005Chairman’sHealthandSafetyAwardinacategoryofLargefacility.Thisrewardispresentedannuallytothecompanywhichhasasafetyrecordthatstandsoutasbeingamongthebestinthecorporation
2007 BecomepartofGeneralCableCorporation.
2008 ChangeditsnametoPhelpsDodgeInternational(Thailand)Limited.
Company Profile Phelps Dodge International (Thailand) Limited is part ofGeneral Cable Corporation – the world’s second-largestmanufacturer of wires and cables with over 45 productionfacilities in 22 countries around the globe. The group’sstrength lies in its superior research and development,leading edge engineering and manufacturing operations, thebroadest product range in the industry, and highly-efficientlogistic capabilities. Plus, with a strong group of associatesseamlessly teaming up to satisfy customers worldwide, wireandcableproductsfromGeneralCableandPDTLhavebecometheundisputedpreferredchoiceamongcustomerworldwide.
The highest Quality and Reliability
Bangplee Plant: Phelps Dodge International (Thailand) Limited facility at Bangplee,Samutprakarn, is one of the most modern wire and cable plants inSoutheastAsiaprovidingworldclassmanufacturingcapabilities.Builtinresponsetotheincreaseindemandforwireandcableproducts,theplants incorporates the latest technology and highest quality controlstandardsthroughouttheproductionprocess.Atpresent,thecomplexfeaturesaverticalcontinuousvulcanization (VCV) tower,which is thefirst vertical crosslink high voltage insulating unit in southeast Asiaand one of the few of its kind in the world. The facility can alsoproduce low voltage power cables, internal and externaltelecommunicationscables,andlocalareanetworkcable.TheCompanyhas2moreHorizontalCVlineswithmostmodernHighVoltage Test Laboratory. Plant has been designed to take ultimatecare for dust free environment and production high quality MediumVoltage,HighVoltageandExtraHighVoltageXLPECables
Rayong Plant: Phelps Dodge International (Thailand) Limited facility at Rayongspecializes in automated, high-volume building wire production at aworld-class level. It will consolidate all Phelps Dodge International(Thailand)Limitedbuildingwiremanufacturingintoasingle,state-of-artfacility.ItwouldalsoenablePhelpsDodgeInternational(Thailand)Limited futureexpansion into flexiblecords (weldingcables,elevatorcables,etc.)andtheextrusionofmoreadvancedinsulationmaterials(flameretardant,lowhalogenemission,etc.).
Quality Policy & Assurance PhelpsDodgeInternational(Thailand)Limitedfollowscontinuousandstrict procedures throughout every production process. Our qualitycontrol begins with the careful scrutinization of raw materials andcontinuestothetestingoffinalproducts;whereeveryfinishedlengthofcablemustalsopassarigoroustesttomeetrequiredspecificationsbeforeitisshippedtoourcustomers.As part of our standard operating practice, these reliability tests, inmanycasessurpassgeneral industrystandard. Inordertocopewiththe volume and accuracy required of such units introduced inThailand.In fact, Phelps Dodge International (Thailand) Limited is the onlysupplierinThailandwithcompletein-housefacilitiesfortestingpowercableupto400kV.PhelpsDodgeInternational(Thailand)LimitedhasgotitscertificationtypetestfromInternationalIndependentLaboratoriessuchasKEMA,Cable Technology Lab, etc. For LSFOH Cable, Fire Resistant Cable,MediumVoltage,HighVoltageandExtraHighVoltageXLPECables.
Quality Policy ItisthepolicyofPhelpsDodgeInternational(Thailand)Limited.Tomanufactureandmarketproductswhichareofthehighestqualityand reliability. It is also a Phelps Dodge International (Thailand)Limited. Policy to comply with iso 9001, all applicable regulatoryrequirements, customer satisfaction and continually improve theeffectiveness of the quality management system by establishingandreviewingannualqualityobjectivesandtargets.
Product Lines 1. BareCopperandAluminumConductor2. BuildingWiresandInteriorWires3. TelecommunicationsCables4. High Voltage and Extra High Voltage Power
CablewithandwithoutLeadSheath5. LowVoltagePowerCablesandControlCables6. Low Smoke Zero Halogen and Fire Resistant
Cables
Our value customers Phelps Dodge International (Thailand) Limited iscapableofmanufacturingworldclassqualitywireand cable at competitive prices with strict globalstandards.Thecompany is trusted tosupplywireand cable to local state enterprises, distributorsandvariousreputablefirms.ElectricityGeneratingAuthorityofThailand(EGAT)ProvincialElectricityAuthority(PEA)MetropolitanElectricityAuthority(MEA)TOTPublicCompanyLimited(TOT)CATTelecomPublicCompanyLimited(CAT)PhelpsDodgeInternational(Thailand)LimitedhasbeenexportingitsqualitycabletotheU.S.,MiddleEast,AsiaandIndochinaformanyyears.
Production Facilities
ISO 9001 Certification (Maneeyaoffice,BangpleeandRayongPlant)In August 1995, Phelps Dodge International (Thailand)Limitedwasproudtobethefirstelectricwiresandcablefirm in Thailand to obtain the International ISO 9001quality standard certificate for all its factories. Thecompany received the ISO 9001 certificate from theBritish Approvals Services for Cables (BASEC), astandard accreditation authority which has been testingcablesforover20years.For another step of global competitiveness, inSeptember 2000, Phelps Dodge International (Thailand)Limited had accomplished ISO 9001 standard from UL(Underwriters Laboratories Inc.) in replacement of theformercertificatefromBASEC.WithstrictcompliancetotheregulatoryoutlinesandpracticeofUL,PhelpsDodgeInternational (Thailand) Limited committed to thecustomer satisfaction for every product and servicesoffered.Not only international accreditation, Phelps DodgeInternational (Thailand) Limited also obtained ISO 9001certification fromtheThai IndustrialStandards Institute(TISI)forthelocalapprovalinFebruary1997.InFebruary2000,TISIhadempoweredMASCI(ManagementSystemCertificationInstituteThailand)toevaluateandissueISOcertificate to the firms that have fullfilled therequirementsandregulations.
ISO 9001 Version 2000 Certification (Maneeyaoffice,BangpleeandRayongPlant)In order to improve the effectiveness of the qualitymanagementsystemandenhancecustomersatisfactionby meeting customer requirements, the qualitymanagement systems of Maneeya office, Bangplee andRayongPlantwereintegratedandupgradedtoISO9001version 2000. We, therefore, obtained ISO 9001 : 2000certification from Management System Certification(Thailand) (MASCI) and Underwriters Laboratories (UL)inMarchandApril2002respectively.Phelps Dodge International (Thailand) Limited isrecognized as the premier electric wires and cablesmanufacturer thatachievedboth localand internationalstandards.
Environmental, Occupational Health and Safety Policy At Phelps Dodge International (Thailand) Limited, as amanufacturerofwires&cables,•Webelievethatallinjuriesandoccupationalillnesscan
be prevented. Therefore, for the well being of allemployees,theeffectiveoccupationalhealthandsafetymanagementisabasisofthecompany’spolicy
•We believe and realize the importance of the world’senvironmentalprotectionthroughefficientutilizationofnatural resources and minimizing environmentalimpactwhilecontributingtosustainabledevelopment.
•Wealsobelieve thatenvironment,occupationalhealthand safety must be thoroughly integrated with oureffort to produce high quality products at competitiveprice.
PhelpsDodgeInternational(Thailand)Limited,therefore,has established and maintained an environmental,occupational health and safety management systemaccordingtoISO14001,OHSAS18001,TIS18000andBS8800andensurethatit1. complies with relevant environmental, occupational
healthandsafetylegislationandregulations,andwithotherrequirementstowhichthecompanysubscribes;
2.provides the frameworks for setting and reviewing
annual objectives and targets and is implementingprogramsto• continuously improve environmental, occupational
health and safety performance and prevention ofaccidentsandpollution.
• minimize process emissions, waste and improveresourceutilization.
• protectthehealthandsafetyofouremployeesandpeople who may be affected by the company’sactivities.
• devise technological solutions that are sound andcost effective for the environment, occupationalhealthandsafety.
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
Quick Guide to the selection of Building Wires & Interior Wires
PAGE
NO.
BUILDING WIRES AND
INTERIOR WIRES &
CABLES
PHELPS DODGE
TYPE LETTER
CODE NAMESTANDARD CABLE NAME APPLICATION
1 CSC TIS 64-2517 Bare copper stranded conductor (Hard Drawn)
Aerial power transmissionand distribution line
2 CSC TIS 11-2531 Bare copper stranded conductor (Soft Drawn)
Aerial power transmissionand distribution line
3 PD-IV TIS 11-2531table 1
300 V copper cdr., PVCinsulated cable
residential wiring
5 PD-VAF TIS 11-2531table 2
300 V copper cdr., PVCins., PVC jacketed cable(flat type)
residential surface wiring
8 PD-VVR TIS 11-2531table 3
300 V multicore copper cdr.,PVC ins., PVC jacketed cable
residential surface wiring
9 PD-THW TIS 11-2531table 4
750 V copper cdr., PVC ins., fixed wiring for large building and industry
11 PD-VV TIS 11-2531table 5
750 V copper cdr., PVC ins.,PVC jacketed cable
fixed installation
12 PD-VVF TIS 11-2531table 5
750 V copper cdr., PVC ins.,PVC jacketed cable(flat type)
fixed installation
13 PD-NYY TIS 11-2531table 6
750 V copper cdr., PVC ins.,PVC jacketed cable
fixed installation
19 PD-NYY TIS 11-2531table 7
750 V multicore copper cdr.,PVC ins., PVC inner jacket,PVC outer jacketed cable
feeder, branch circuit cable
21 PD-NYY-N TIS 11-2531table 8
750 V multicore copper cdr.,PVC ins., PVC inner jacket,PVC outer jacketed cablewith neutral
feeder, branch circuit cable(for 3 phase, 4 wire system)
25 PD-VCT TIS 11-2531table 9
750 V multicore copper cdr.,PVC ins., PVC inner jacket,PVC outer jacketed cable(flexible conductor)
mobile-electrical equipmentor machine tool wiring
26 PD-VTF TIS 11-2531table 10
300 V copper cdr., PVC ins.(twist type, flexible cdr.)
small indoor electricalappliance
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
Quick Guide to the selection of Building Wires & Interior Wires
PAGE
NO.
BUILDING WIRES AND
INTERIOR WIRES &
CABLES
PHELPS DODGE
TYPE LETTER
CODE NAMESTANDARD CABLE NAME APPLICATION
27 PD-VFF TIS 11-2531table 10
300 V copper cdr., PVCins. (flat twin, flexible cdr.)
small indoor electricalappliance
28 PD-VSF TIS 11-2531table 10
300 V copper cdr., PVCinsulated single core(flexible cdr.)
small electricalappliance
29 PD-VAF-G TIS 11-2531table 11
300 V copper cdr., PVCins. PVC jacketed cablewith ground (flat type)
residential surface wiring
33 PD-VVR-G TIS 11-2531table 12
300 V copper cdr., PVCins. PVC jacketed cablewith ground
fixed installation with ground system
34 PD-VVF-G TIS 11-2531table 13
750 V copper cdr., PVCinsulated, PVC jacketwith ground (flat type)
surface wiring on wallceiling or floor
35 PD-NYY-G TIS 11-2531table 14
750 V copper cdr., PVCins., PVC jacked cablewith ground
fixed installtion with ground system
41 PD-VCT-G TIS 11-2531table 15
750 V copper cdr., PVCinsulated. PVC inner andouter jacket with ground(flexible conductor)
mobile-electrical equipmentor machine tool wiring
44 PD-VFF-G TIS 11-2531table 16
300 V copper cdr., PVCins. with ground(flat type, flexible cdr.)
small indoor electrical appliance with ground system
45 PD-VAFF TIS 11-2531table 17
300 V copper cdr., PVCPVC jacketed cable(flat type, flexible cdr.)
For surface or above ceiling wiring or directembeded in plaster
47 XHHW-2 UL 44 600 V Aluminum Alloy cdr.,UL recognized cross-linkedpolyethylene ins.
general purpose buildingwire for installation in air,duct, conduit or other raceways.
48 XHHW,XHHW-2
UL 44 600 V copper cdr.,UL recognized cross-linkedpolyethylene insulated wire
general purpose buildingwire for installation in air,duct, conduit or other raceways.
49 THHN-THWN UL 83UL 758UL 1063
600 V copper cdr.,UL recognized thermoplastic insulated wire
general purpose buildingwire for services, feedersand branch circuit conduitand raceway
Quick Guide to the selection of Building Wires & Interior Wires
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 01
Application :Aerial power transmission and distribution line.
Reference Standard :TIS 64-2517
Conductor :Hard drawn copper wire, concentric stranded conductor Sizes 10 mm2 up to 500 mm2
R = Packing in reel
PHELPS DODGE CONDUCTOR TYPE CSC BARE COPPER STRANDED CONDUCTOR
HARD DRAWN COPPER WIRES
Nominal
Sectional
Area
mm2
1016253550507095120150185240300400500
Number &
Diameter
of Wire
No. / mm
7/1.357/1.707/2.147/2.527/3.0219/1.7819/2.1419/2.5219/2.8537/2.2537/2.5261/2.2561/2.5261/2.8561/3.20
Overall
Diameter
mm
4.055.106.427.569.068.9010.7012.6014.2515.7517.6420.2522.6825.6528.80
Maximum
Conductor
Resistance
at 20°C
/ km
1.805481.138570.718510.518150.358960.382520.264660.191830.149220.123840.098130.075280.060020.046920.03703
Breaking
Strength
(kgf)
438694
1,0761,4592,0952,0212,9213,9615,0676,2897,71310,36912,71716,26620,506
Allowable
Ampacities
In Free Air
(A)
90125160200250250310380440510585700800900
1,110
Cable
Weight
kg / km
90143227314452428618858
1,0971,3341,6732,2002,7603,3504,451
Standard
Packing
(m)
1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200802
Application :Aerial power transmission and distribution line.
Reference Standard :TIS 11-2531
Conductor :Soft drawn copper wire, concentric stranded conductor Sizes 10 mm2 up to 500 mm2
R = Packing in reel
PHELPS DODGE CONDUCTOR TYPE CSC BARE ANNEALED COPPER STRANDED CONDUCTOR
SOFT DRAWN (ANNEALED) COPPER WIRES
Nominal
Sectional
Area
mm2
10162535507095120150185240300400500
Number &
Diameter
of Wire
No. / mm
7/1.357/1.707/2.1419/1.5319/1.7819/2.1419/2.5237/2.0337/2.2537/2.5261/2.2561/2.5261/2.8561/3.20
Overall
Diameter
mm
4.055.106.427.658.9010.7012.6014.2115.7517.6420.2522.6825.6528.80
Maximum
Conductor
Resistance
at 20°C
/ km
1.831.150.7270.5240.3870.2680.1930.1530.124
0.09910.07540.06010.04700.0366
Allowable
Ampacities
In Free Air
A
90125160200250310380440510585700800900
1,110
Cable
Weight
(approx)
kg / km
90143227314428618858
1,0971,3341,6732,2002,7603,3504,451
Standard
Packing
m
1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R1,000/R
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 03
Application :Building wiring, for installation on insulator or in raceway, dry and wet location.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 1
Construction :Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 150 mm2
Insulation : Polyvinyl chloride (Any colour as requested)
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
0.5 PD-IV1 PD-IV1 PD-IV1.5 PD-IV1.5 PD-IV2.5 PD-IV2.5 PD-IV4 PD-IV4 PD-IV6 PD-IV10 PD-IV16 PD-IV25 PD-IV35 PD-IV50 PD-IV70 PD-IV95 PD-IV120 PD-IV150 PD-IV
Nominal
Sectional Area
mm2
0.511
1.51.52.52.5446
10162535507095120150
Overall
Diameter
mm
2.62.93.13.23.43.84.14.54.95.67.08.210.011.513.015.017.519.021.5
Allowable
Ampacities
Free Air
40°C
A91414181825253434446284113141171221271315365
Minimum
Insulation
Resistance
at 70°C
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00640.00530.00510.00430.00440.00370.00360.00320.0033
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.5319/1.7819/2.1419/2.5237/2.0337/2.25
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.81.01.01.21.21.41.41.61.61.8
Cable
Weight
(approx)
kg / km
8.5141419193131484870120180280380530720990
1,2301,510
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R500/R500/R500/R
PHELPS DODGE CONDUCTOR TYPE PD-IV 300 V 70oC PVC INSULATED, SINGLE CORE
Conductor PVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
Application : For surface or above ceiling wiring or direct embeded in plaster
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 2
Construction : Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
04
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
2 x 0.5 PD-VAF2 x 1 PD-VAF2 x 1 PD-VAF2 x 1.5 PD-VAF2 x 1.5 PD-VAF2 x 2.5 PD-VAF2 x 2.5 PD-VAF2 x 4 PD-VAF2 x 4 PD-VAF2 x 6 PD-VAF2 x 10 PD-VAF2 x 16 PD-VAF2 x 25 PD-VAF2 x 35 PD-VAF
Nominal
Sectional Area
mm2
0.511
1.51.52.52.5446
10162535
Overall
Dimension
mm
4.4x6.84.8x7.45.0x7.85.8x8.66.0x9.26.4x10.06.8x10.57.2x11.57.6x12.08.2x13.59.4x16.0
11.0x18.513.0x22.514.5x25.0
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.80.91.01.21.2
Thickness
of
Sheath
mm
0.90.90.91.21.21.21.21.21.21.21.21.21.41.4
Allowable
Ampacities
Free Air
40°C
A8
131317172323303040557497120
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R
Minimum
Insulation
Resistance
at 70°C
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00590.00530.00510.0043
Cable
Weight
(approx)
kg / km
3750507070100100140140200300440690900
PHELPS DODGE CONDUCTOR TYPE PD-VAF (MEA TYPE B) 300 V 70 oC PVC INSULATED AND SHEATHED FLAT TYPE, TWO CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
Application :Building wiring for installation on insulator or in raceway, dry and wet location.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 2
Construction :Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 16 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
05
PHELPS DODGE CONDUCTOR TYPE PD-VAF (MEA TYPE B) 300 V 70 oC PVC INSULATED AND SHEATHED FLAT TYPE, TWO CORE
PHELPS DODGE CONDUCTOR TYPE PD-VAF 300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, THREE CORE
PHELPS DODGE
TYPE LETTER
3 x 0.5 PD-VAF3 x 1 PD-VAF3 x 1 PD-VAF3 x 1.5 PD-VAF3 x 1.5 PD-VAF3 x 2.5 PD-VAF3 x 2.5 PD-VAF3 x 4 PD-VAF3 x 4 PD-VAF3 x 6 PD-VAF3 x 10 PD-VAF3 x 16 PD-VAF
Nominal
Sectional Area
mm2
0.511
1.51.52.52.54461016
Overall
Dimension
mm
4.4x9.04.8x10.05.0x10.55.8x11.56.0x12.56.4x13.56.8x14.57.2x16.07.6x16.58.2x18.59.4x22.011.5x26.5
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.70
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.80.91.0
Thickness
of
Sheath
mm
0.90.90.91.21.21.21.21.21.21.21.21.4
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R
Allowable
Ampacities
Free Air
40°C
A6.5
11.511.5151521212828365066
Minimum
Insulation
Resistance
at 70°C
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00590.0053
Cable
Weight
(approx)
kg / km
4155557777110110154154220363484
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200806
R = Packing in reel
Application : Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 3
Construction : Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE
TYPE LETTER
2 x 0.5 PD-VVR2 x 1 PD-VVR2 x 1 PD-VVR2 x 1.5 PD-VVR2 x 1.5 PD-VVR2 x 2.5 PD-VVR2 x 2.5 PD-VVR2 x 4 PD-VVR2 x 4 PD-VVR2 x 6 PD-VVR2 x 10 PD-VVR2 x 16 PD-VVR2 x 25 PD-VVR2 x 35 PD-VVR
Nominal
Sectional Area
mm2
0.511
1.51.52.52.5446
10162535
Overall
Dimension
mm
6.87.68.08.89.2
10.011.011.512.513.516.019.022.525.5
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.80.91.01.21.2
Thickness
of
Sheath
mm
0.90.90.91.21.21.21.21.21.21.21.21.41.41.4
Standard
Packing
(m)
500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A8
131317172323303040557497120
Minimum
Insulation
Resistance
at 70°C
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00590.00530.00510.0043
Cable
Weight
(approx)
kg / km
4865659090130130180180260390580870
1,130
PHELPS DODGE CONDUCTOR TYPE PD-VVR 300 V 70oC PVC INSULATED AND SHEATHED, TWO CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 07
Application :Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 3
Construction :Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
R = Packing in reel
PHELPS DODGE
TYPE LETTER
3 x 0.5 PD-VVR3 x 1 PD-VVR3 x 1 PD-VVR3 x 1.5 PD-VVR3 x 1.5 PD-VVR3 x 2.5 PD-VVR3 x 2.5 PD-VVR3 x 4 PD-VVR3 x 4 PD-VVR3 x 6 PD-VVR3 x 10 PD-VVR3 x 16 PD-VVR3 x 25 PD-VVR3 x 35 PD-VVR
Nominal
Sectional Area
mm2
0.511
1.51.52.52.544610162535
Overall
Dimension
mm
7.28.08.49.29.610.511.512.513.014.517.020.025.028.0
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.80.91.01.21.2
Thickness
of
Sheath
mm
0.90.90.91.21.21.21.21.21.21.21.21.41.81.8
Standard
Packing
(m)
500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A6.511.511.515152121282836506684104
Minimum
Insulation
Resistance
at 70°C
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00590.00530.00510.0043
Cable
Weight
(approx)
kg / km
558080110110160160230230330490740
1,1801,530
PHELPS DODGE CONDUCTOR TYPE PD-VVR 300 V 70oC PVC INSULATED AND SHEATHED, THREE CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
R = Packing in reel
Application :Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 3
Construction : Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black, Red and Blue colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
08
PHELPS DODGE
TYPE LETTER
4 x 0.5 PD-VVR4 x 1 PD-VVR4 x 1 PD-VVR4 x 1.5 PD-VVR4 x 1.5 PD-VVR4 x 2.5 PD-VVR4 x 2.5 PD-VVR4 x 4 PD-VVR4 x 4 PD-VVR4 x 6 PD-VVR4 x 10 PD-VVR4 x 16 PD-VVR4 x 25 PD-VVR4 x 35 PD-VVR
Nominal
Sectional Area
mm2
0.511
1.51.52.52.5446
10162535
Overall
Dimension
mm
7.88.69.0
10.010.511.512.513.514.015.519.022.027.530.5
Number &
Diameter
of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.60.60.60.60.60.70.70.80.80.80.91.01.21.2
Thickness
of
Sheath
mm
0.90.90.91.21.21.21.21.21.21.21.41.41.81.8
Standard
Packing
m
500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A6.5
11.511.515152121282836506684104
Minimum
Insulation
Resistance
M - km
0.01460.01150.01100.01000.00940.00920.00840.00860.00780.00660.00590.00530.00510.0043
Cable
Weight
(approx)
kg / km
65100100130130190190290290410640940
1,4901,950
PHELPS DODGE CONDUCTOR TYPE PD-VVR 300 V 70oC PVC INSULATED AND SHEATHED, FOUR CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
09
Application :Building wiring for installation on insulator or in raceway, dry and wet location.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 4
Construction : Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 500 mm2
Insulation : Heat resistance polyvinyl chloride (Any colour as requested)
PHELPS DODGE
TYPE LETTER
0.5 PD-THW1 PD-THW1 PD-THW1.5 PD-THW1.5 PD-THW2.5 PD-THW2.5 PD-THW4 PD-THW4 PD-THW6 PD-THW10 PD-THW16 PD-THW
Nominal
Aectional Area
mm2
0.511
1.51.52.52.5446
1016
Number &
Diameter of Wire
No. / mm
1/0.801/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.70
Thickness
of
insulation
mm
0.80.80.80.80.80.80.80.90.90.91.11.1
Overall
Diameter
mm
3.03.33.53.63.84.04.34.85.25.87.28.4
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C
Allowable
Ampacities
Free Air
40°C
A111616212129293939517096
Minimum
Insulation
Resistance
at 70°C
M - km
0.01750.01410.01350.01230.01160.01020.00930.00940.00850.00730.00690.0057
Cable
Weight
(approx)
kg / km
11171722223131505075120180
PHELPS DODGE CONDUCTOR TYPE PD-VVR 300 V 70oC PVC INSULATED AND SHEATHED, FOUR CORE
PHELPS DODGE CONDUCTOR TYPE PD-THW (MEA TYPE A) 750 V 70oC PVC INSULATED SINGLE CORE
Conductor PVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
10
PHELPS DODGE
TYPE LETTER
25 PD-THW35 PD-THW50 PD-THW70 PD-THW95 PD-THW120 PD-THW150 PD-THW185 PD-THW240 PD-THW300 PD-THW400 PD-THW500 PD-THW
Nominal
Sectional Area
mm2
2535507095120150185240300400500
Overall
Dimension
mm
10.511.513.515.518.019.521.524.027.030.033.538.0
Number &
Diameter
of Wire
No. / mm
7/2.1419/1.5319/1.7819/2.1419/2.5237/2.0337/2.2537/2.5261/2.2561/2.5261/2.8561/3.20
Thickness
of
Insulation
mm
1.31.31.51.51.71.71.92.12.32.52.73.1
Standard
Packing
m
100/C100/C500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A127157191244297345397453535617741854
Minimum
Insulation
Resistance
at 70°C
M - km
0.00540.00470.00460.00390.00380.00340.00340.00340.00330.00320.00300.0031
Cable
Weight
(approx)
kg / km
290380540720
1,0001,2401,5201,9002,4803,1003,9505,150
PHELPS DODGE CONDUCTOR TYPE PD-THW (MEA TYPE A) 750 V 70oC PVC INSULATED SINGLE CORE
Application :Building wiring for installation on insulator or in raceway, dry and wet location.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 4
Construction : Conductor : Annealed copper, solid or strandedSizes 0.5 mm2 up to 500 mm2
Insulation : Heat resistance polyvinyl chloride (Any colour as requested)
Conductor PVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 11
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
1 PD-VV1 PD-VV1.5 PD-VV1.5 PD-VV2.5 PD-VV 2.5 PD-VV4 PD-VV4 PD-VV6 PD-VV10 PD-VV16 PD-VV25 PD-VV35 PD-VV
Nominal
Sectional Area
mm2
11
1.51.52.52.544610162535
Overall
Dimension
mm
5.45.65.86.06.67.07.47.88.810.511.513.515.0
Number &
Diameter
of Wire
No. / mm
1/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.80.80.80.80.80.80.90.90.91.11.11.31.3
Thickness
of
Sheath
mm
1.01.01.01.01.21.21.21.21.41.41.51.51.6
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R
Allowable
Ampacities
Free Air
40°C
A1616212129293939517096127157
Minimum
Insulation
Resistance
at 70°C
M - km
0.01410.01350.01230.01160.01020.00930.00940.00850.00730.00690.00570.00540.0047
Cable
Weight
(approx)
kg / km
3535414160608080120170250360407
PHELPS DODGE CONDUCTOR TYPE PD-VV (MEA TYPE B) 750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Application : For fixed installation in wet or dry location. The cable is suitable for surface wiring or concealed wiring in wooden partition.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 5
Construction : Conductor : Annealed copper, solid or strandedSizes 1 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
12
PHELPS DODGE
TYPE LETTER
2 X 1 PD-VVF2 x 1 PD-VVF2 x 1.5 PD-VVF2 x 1.5 PD-VVF2 x 2.5 PD-VVF2 x 2.5 PD-VVF2 x 4 PD-VVF2 x 4 PD-VVF2 x 6 PD-VVF2 x 10 PD-VVF2 x 16 PD-VVF2 x 25 PD-VVF2 x 35 PD-VVF
Nominal
Sectional Area
mm2
11
1.51.52.52.5446
10162535
Overall
Diameter
mm
6.4 x 9.46.6 x 9.8
6.6 x 10.07.0 x 10.57.2 x 11.07.4 x 11.57.8 x 12.58.2 x 13.08.8 x 14.5
10.5 x 17.011.5 x 19.513.5 x 23.515.0 x 26.5
Number &
Diameter
of Wire
No. / mm
1/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.1419/1.53
Thickness
of
Insulation
mm
0.80.80.80.80.80.80.90.90.91.11.11.31.3
Thickness
of
Sheath
mm
1.41.41.41.41.41.41.41.41.41.51.51.61.7
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A131317172323303040557497120
Minimum
Insulation
Resistance
at 70°C
M - km
0.01410.01350.01230.01160.01020.00930.00940.00850.00730.00690.00570.00540.0047
Cable
Weight
(approx)
kg / km
75759090110110160160220340480720940
PHELPS DODGE CONDUCTOR TYPE PD-VVF 750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE
Application :For fixed installation in wet or dry location. The cable is suitable for surface wiring or concealed wiring in wooden partition.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 5
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
Application : For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 6
Construction : Conductor : Annealed copper, solid or strandedSizes 1 mm2 up to 500 mm2
Insulation : Heat resistance polyvinyl chloride (Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
C = Packing in coilR = Packing in reel
13
PHELPS DODGE
TYPE LETTER
1 PD-NYY1 PD-NYY1.5 PD-NYY1.5 PD-NYY2.5 PD-NYY2.5 PD-NYY4 PD-NYY4 PD-NYY6 PD-NYY10 PD-NYY16 PD-NYY25 PD-NYY
Nominal
Aectional Area
mm2
11
1.51.52.52.5446
101625
Number &
Diameter of wire
No. / mm
1/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.707/2.14
Thickness
of
Insulation
mm
1.51.51.51.51.51.51.51.51.51.51.51.5
Thickness
of
Sheath
mm
1.81.81.81.81.81.81.81.81.81.81.81.8
Overall
Diameter
mm
8.68.89.09.29.49.8
10.010.511.012.013.014.5
Standard
Packing
m
100/C100/C100/C100/C100/C100/C100/C100/C100/C500/R500/R500/R
Allowable
Ampacities
Free Air
40°C
A1616212129293939517096127
Minimum
Insulation
Resistance
at 70°C
M - km
0.02070.02000.01840.01750.01570.01460.01350.01240.01070.00880.00740.0061
Cable
Weight
(approx)
kg / km
80809090100100130130160210280390
PHELPS DODGE CONDUCTOR TYPE PD-VVF 750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
14
PHELPS DODGE
TYPE LETTER
35 PD-NYY50 PD-NYY70 PD-NYY95 PD-NYY120 PD-NYY150 PD-NYY185 PD-NYY240 PD-NYY300 PD-NYY400 PD-NYY500 PD-NYY
Nominal
Sectional
Area
mm2
35507095120150185240300400500
Number &
Diameter
of Wire
No. / mm
19/1.5319/1.7819/2.1419/2.5237/2.0337/2.2537/2.5261/2.2561/2.5261/2.8561/3.20
Thickness
of
Insulation
mm
1.51.51.51.71.71.92.12.32.52.73.1
Thickness
of
Sheath
mm
1.81.81.81.81.82.02.02.22.22.22.4
Standard
Packing
m
500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Overall
Diameter
mm
16.017.019.021.523.026.028.031.535.038.543.0
Allowable
Ampacities
Free Air
40°C
A157191244297345397453535617741854
Minimum
Insulation
Resistance
at 70°C
M - km
0.00530.00460.00390.00380.00340.00340.00340.00330.00320.00300.0031
Cable
Weight
(approx)
kg / km
500660850
1,1501,4001,7202,1302,7603,4004,2905,570
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND SHEATHED, SINGLE CORE
Application : For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 6
Construction : Conductor : Annealed copper, solid or strandedSizes 1 mm2 up to 500 mm2
Insulation : Heat resistance polyvinyl chloride (Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 15
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
2 x 1 PD-NYY2 x 1 PD-NYY2 x 1.5 PD-NYY2 x 1.5 PD-NYY2 x 2.5 PD-NYY2 x 2.5 PD-NYY2 x 4 PD-NYY2 x 4 PD-NYY2 x 6 PD-NYY2 x 10 PD-NYY2 x 16 PD-NYY
Nominal
Sectional
Area
mm2
11
1.51.52.52.54461016
Number &
Diameter
of Wire
No. / mm
1/1.137/0.401/1.387/0.501/1.787/0.671/2.257/0.857/1.047/1.357/1.70
Thickness
of
Insulation
mm
0.80.80.80.80.80.80.90.90.91.11.1
Thickness
of Inner
Sheath
mm
0.80.80.80.80.80.80.80.80.80.80.8
Thickness
of Outer
Sheath
mm
1.81.81.81.81.81.81.81.81.81.82.0
Standard
Packing
m
500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R500/R
Overall
Diameter
mm
12.012.512.513.013.514.015.015.517.019.522.5
Allowable
Ampacities
Free Air
40°C
A1313171723233030405574
Minimum
Insulation
Resistance
at 70°C
M - km
0.01410.01350.01230.01160.01020.00930.00940.00850.00730.00690.0057
Cable
Weight
(approx)
kg / km
160160180180210210280280370530720
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE
Application :For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction : Conductor : Annealed copper, solid or strandedSizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
16
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE
Application : For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction : Conductor : Annealed copper, solid or strandedSizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 17
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE
Application :For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
18
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE
Application :For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
19
Application :For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black Red and Blue colour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200820
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-NYY (MEA TYPE C) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE
Application :For installation exposed, or in raceway, wet or dry location, ordirect burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 7
Construction :Conducor : Annealed copper, solidor strandedSizes 1 mm2 up to 300 mm2
Insulation : Heat resistance polyvinylchloride (Gray, Black, Red and Bluecolour)
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistancepolyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
21
PHELPS DODGE CONDUCTOR TYPE PD-NYY-N (MEA TYPE C-N) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE PHASE WITH NEUTRAL
Application :For installation exposed, or in raceway, wet or dry location, or direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 8
Construction :Conducor : Annealed copper,concentric or strandedSizes 6 mm2 up to 300 mm2 (Phase)Sizes 4 mm2 up to 150 mm2 (Neutral)
Insulation : Heat resistance polyvinylchloride (Black, Red, and Blue)Phase, (Gray colour) Neutral.
Inner sheath : Heat resistancepolyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
PVC insulation
PVC inner sheath
PVC outer sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200822
C = Packing in coilR = Packing in reel
Application :For mobile-electrical equipmentused in mines, factories, farm orhousehold appliances. This cableis particularly suitable for use inchemical factories or in place where cables come in contact with oils.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 9
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 95 mm2
Insulation : Heat resistance polyvinyl chloride (Black colour)
sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-VCT 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE SINGLE CORE
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 23
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VCT 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE TWO CORE
Application :For mobile-electrical equipmentused in mines, factories, farm orhousehold appliances. This cableis particularly suitable for use inchemical factories or in places wherecables come in contact with oils.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 9
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinylchloride (Gray and Black colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200824
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VCT 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE
Application :For mobile-electrical equipmentused in mines, factories, farm orhousehold appliances. This cableis particularly suitable for use inchemical factories or in places wherecables come in contact with oils.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 9
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinylchloride (Gray, Black and Red colour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 25
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VCT 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE
PHELPS DODGE CONDUCTOR TYPE PD-VCT 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE FOUR CORE
Application :For mobile-electrical equipmentused in mines, factories, farm orhousehold appliances. This cableis particularly suitable for use inchemical factories or in places wherecables come in contact with oils.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 9
Construction :Conductor : Annealed copper, solidor strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinylchloride (Gray, Black, Red and Bluecolour)
Sheath : Heat resistance polyvinyl chloride (Black colour)
Conductor
PVC insulation
PVC sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200826
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VTF 300 V 70oC PVC INSULATED TWISTED, FLEXIBLE TWO CORE
Application :For used mainly for small indoorelectrical appliances such asdesk-lamp, radios, fans, electric hotplate etc.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 10
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 2.5 mm2
Insulation : Heat resistance polyvinylchloride (Gray and Black colour)
Conductor
PVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 27
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VFF 300 V 70oC PVC INSULATED FLAT TYPE, FLEXIBLE TWO CORE
Application :For used in dryroom for small indoorelectrical appliances such asdesk-lamp, radios, fans etc.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 10
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 2.5 mm2
Insulation : Heat resistance polyvinylchloride (Any colour as requested)
ConductorPVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
28
PHELPS DODGE CONDUCTOR TYPE PD-VSF 300 V 70oC PVC INSULATED, FLEXIBLE SINGLE CORE
Application :For making cross connection between terminals inside appliances,instruments or apparatus.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 10
Construction :Conductor : Annealed copper,bunch strandedSizes 0.5 mm2 up to 2.5 mm2
Insulation : Polyvinyl chloride (Any colour as requested)
ConductorPVC insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 29
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VAF-G (MEA TYPE B-GRD) 300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, TWO CORE WITH GROUND
Application :Surfaced wiring. Concealed wiringin wooden partition, or above ceiling.Embed in plaster
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 11
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Polyvinyl chloride (Grayand Black colour) Phase, (Greenwith Yellow Stripe colour) Ground
Sheath : Polyvinyl chloride (Whitecolour)
Phase Conductor
PVC Insulation
Ground Conductor
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coil
30
PHELPS DODGE CONDUCTOR TYPE PD-VAF-G 300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, THREE CORE WITH GROUND
Application :Surfaced wiring. Concealed wiringin wooden partition, or above ceiling.Embed in plaster.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 11
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 16 mm2 (Phase)Sizes 1 mm2 up to 6 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray, Black and Red colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance Polyvinyl chloride (White colour)
Phase Conductor
PVC Insulation
Ground Conductor
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
R = Packing in reel
31
PHELPS DODGE CONDUCTOR TYPE PD-VAF-G 300 V 70oC PVC INSULATED AND SHEATHED FLAT TYPE, THREE CORE WITH GROUND
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G 300 V 70oC PVC INSULATED AND SHEATHED, TWO CORE WITH GROUND
Application :Exposed wiring in air or in raceway.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 12
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray and Black colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
R = Packing in reel
32
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G 300 V 70oC PVC INSULATED AND SHEATHED, THREE CORE WITH GROUND
Application :Exposed wiring in air or in raceway.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 12
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray, Black and Red colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
PHELPS DODGE
TYPE LETTER
3 x 1/1 PD-VVR-G
3 x 1/1 PD-VVR-G
3 x 1.5/1 PD-VVR-G
3 x 1.5/1 PD-VVR-G
3 x 2.5/1.5 PD-VVR-G
3 x 2.5/1.5 PD-VVR-G
3 x 4/2.5 PD-VVR-G
3 x 4/2.5 PD-VVR-G
3 x 6/4 PD-VVR-G
3 x 10/4 PD-VVR-G
3 x 16/6 PD-VVR-G
3 x 25/6 PD-VVR-G
3 x 35/10 PD-VVR-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
6
10
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
7/1.04
7/1.35
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.2
1.2
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Insulation
Diameter Max
mm
8.6
9.0
10.0
10.5
11.5
12.5
13.5
14.0
15.5
18.5
22.0
27.5
30.5
Allowable
Ampacities
Free Air
40°C
A
11.5
11.5
15
15
21
21
28
28
36
50
66
84
104
Minimum
Insulation
Resistance
at 70°C
M - km
0.0115
0.0110
0.0100
0.0094
0.0092
0.0084
0.0086
0.0078
0.0066
0.0059
0.0053
0.0051
0.0043
Cable
Weight
(approx)
kg / km
95
95
130
130
180
180
260
260
370
530
800
1,220
1,610
Thickness
of
Sheath
mm
0.9
0.9
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.8
1.8
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
R = Packing in reel
33
PHELPS DODGE CONDUCTOR TYPE PD-VVR-G 300 V 70oC PVC INSULATED AND SHEATHED, FOUR CORE WITH GROUND
Application :Exposed wiring in air or in raceway.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 12
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray, Black Red and Blue colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
PHELPS DODGE
TYPE LETTER
4 x 1/1 PD-VVR-G
4 x1/1 PD-VVR-G
4 x 1.5/1 PD-VVR-G
4 x 1.5/1 PD-VVR-G
4 x 2.5/1.5 PD-VVR-G
4 x 2.5/1.5 PD-VVR-G
4 x 4/2.5 PD-VVR-G
4 x 4/2.5 PD-VVR-G
4 x 6/4 PD-VVR-G
4 x 10/4 PD-VVR-G
4 x 16/6 PD-VVR-G
4 x 25/6 PD-VVR-G
4 x 35/10 PD-VVR-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
6
10
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
7/1.04
7/1.35
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.2
1.2
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Insulation
Diameter Max
mm
9.2
9.8
11.0
11.5
12.5
13.5
14.5
15.5
17.0
20.5
24.5
30.0
33.5
Allowable
Ampacities
Free Air
40°C
A
11.5
11.5
15
15
21
21
28
28
36
50
66
84
104
Minimum
Insulation
Resistance
at 70°C
M - km
0.0115
0.0110
0.0100
0.0094
0.0092
0.0084
0.0086
0.0078
0.0066
0.0059
0.0053
0.0051
0.0043
Cable
Weight
(approx)
kg / km
110
110
150
150
220
220
330
330
470
700
1,030
1,570
2,070
Thickness
of
Sheath
mm
0.9
0.9
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.8
1.8
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200834
C = Packing in coilR = Packing in reel
PHELPS DODGE CONDUCTOR TYPE PD-VVF-G 750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE WITH GROUND
Application :For fixed installation in damplocation. The cable is suitable forsurface wiring or concealed wiringin wooden partition. The groundconductor accompany in the cablecaused the cable being suitable foruse in grounded electrical system.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 13
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray and Black colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (White colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
PHELPS DODGE
TYPE LETTER
2 x 1/1 PD-VVF-G
2 x 1/1 PD-VVF-G
2 x 1.5/1 PD-VVF-G
2 x 1.5/1 PD-VVF-G
2 x 2.5/1.5 PD-VVF-G
2 x 2.5/1.5 PD-VVF-G
2 x 4/2.5 PD-VVF-G
2 x 4/2.5 PD-VVF-G
2 x 6/4 PD-VVF-G
2 x 10/4 PD-VVF-G
2 x 16/6 PD-VVF-G
2 x 25/6 PD-VVF-G
2 x 35/10 PD-VVF-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
6
10
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
7/2.14
19/1.53
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
7/1.04
7/1.35
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.1
1.1
1.3
1.3
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Dimension
mm
6.4 x 12.0
6.6 x 12.5
6.6 x 12.5
7.0 x 13.0
7.2 x 14.0
7.4 x 14.5
7.8 x 15.5
8.2 x 16.5
8.8 x 18.5
10.5 x 21.5
11.5 x 24.5
13.5 x 28.0
15.0 x 32.0
Allowable
Ampacities
Free Air
40°C
A
13
13
17
17
23
23
30
30
40
55
74
97
120
Minimum
Insulation
Resistance
at 70°C
M - km
0.0141
0.0135
0.0123
0.0116
0.0102
0.0093
0.0094
0.0085
0.0073
0.0069
0.0057
0.0054
0.0047
Cable
Weight
(approx)
kg / km
100
100
120
120
150
150
210
210
290
420
590
840
1,120
Thickness
of
Sheath
mm
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.7
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
C = Packing in coilR = Packing in reel
35
PHELPS DODGE
TYPE LETTER
2 x 1/1 PD-NYY-G
2 x 1/1 PD-NYY-G
2 x 1.5/1 PD-NYY-G
2 x 1.5/1 PD-NYY-G
2 x 2.5/1.5 PD-NYY-G
2 x 2.5/1.5 PD-NYY-G
2 x 4/2.5 PD-NYY-G
2 x 4/2.5 PD-NYY-G
2 x 6/4 PD-NYY-G
2 x 10/4 PD-NYY-G
2 x 16/6 PD-NYY-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.1
1.1
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
12.5
13.0
13.0
13.5
14.0
15.0
15.5
16.5
18.0
19.5
22.5
Thickness
of Inner
Sheath
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
Thickness
of Outer
Sheath
mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
Allowable
Ampacities
Free Air
40°C
A
13
13
17
17
23
23
30
30
40
55
74
Minimum
Insulation
Resistance
at 70°C
M - km
0.0141
0.0135
0.0123
0.0116
0.0102
0.0093
0.0094
0.0085
0.0073
0.0069
0.0057
Cable
Weight
(approx)
kg / km
170
170
190
190
230
230
300
300
400
550
760
PHELPS DODGE CONDUCTOR TYPE PD-VVF-G 750 V 70oC PVC INSULATED AND SHEATHED, FLAT TYPE, TWO CORE WITH GROUND
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE PD-NYY-G) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE WITH GROUND
Application :Exposed wiring in air or use inraceway wet or dry location, directburial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray and Black colour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistancepolyvinyl chloride (Black colour)
Outer sheath : Heat resistancepolyvinyl chloride (Black colour)
PVC Insulation
Phase Conductor
Ground Conductor
PVC Inner Sheath
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200836
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
2 x 25/6 PD-NYY-G2 x 35/10 PD-NYY-G2 x 50/10 PD-NYY-G2 x 70/10 PD-NYY-G2 x 95/16 PD-NYY-G2 x 120/16 PD-NYY-G2 x 150/25 PD-NYY-G2 x 185/25 PD-NYY-G2 x 240/35 PD-NYY-G2 x 300/35 PD-NYY-G
Nominal
Sectional
Area
mm2
25
35
50
70
95
120
150
185
240
300
Nominal
Sectional
Area
mm2
6
10
10
10
16
16
25
25
35
35
Phase core
Number &
Diameter
of Wire
No. / mm
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
Ground core
Number &
Diameter
of Wire
No. / mm
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/2.14
7/2.14
19/1.53
19/1.53
Thickness
of
Insulation
mm
1.3
1.3
1.5
1.5
1.7
1.7
1.9
2.1
2.3
2.5
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
200/R
200/R
150/R
150/R
Overall
Diameter
mm
27.0
29.5
33.5
38.0
42.5
46.5
52.0
57.0
64.0
70.5
Thickness
of Inner
Sheath
mm
1.2
1.2
1.2
1.5
1.5
1.5
1.8
1.8
2.0
2.0
Thickness
of Outer
Sheath
mm
2.0
2.0
2.2
2.2
2.2
2.4
2.6
2.8
3.0
3.2
Allowable
Ampacities
Free Air
40°C
A
97
120
146
185
224
260
299
341
401
461
Minimum
Insulation
Resistance
at 70°C
M - km
0.0054
0.0047
0.0046
0.0039
0.0038
0.0034
0.0034
0.0034
0.0033
0.0032
Cable
Weight
(approx)
kg / km
1,110
1,410
1,900
2,430
3,230
3,920
4,870
5,940
7,680
9,350
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, TWO CORE WITH GROUND
Application :Exposed wiring in air or use inraceway wet or dry location, directburial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray and Black colour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistancepolyvinyl chloride (Black colour)
Outer sheath : Heat resistancepolyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Inner Sheath
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 37
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
3 x 1/1 PD-NYY-G3 x 1/1 PD-NYY-G3 x 1.5/1 PD-NYY-G3 x 1.5/1 PD-NYY-G3 x 2.5/1.5 PD-NYY-G3 x 2.5/1.5 PD-NYY-G3 x 4/2.5 PD-NYY-G3 x 4/2.5 PD-NYY-G3 x 6/4 PD-NYY-G3 x 10/4 PD-NYY-G3 x 16/6 PD-NYY-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.1
1.1
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
13.5
14.0
14.0
14.5
15.0
16.0
17.0
17.5
19.0
22.5
26.5
Thickness
of Inner
Sheath
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.2
Thickness
of Outer
Sheath
mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
Allowable
Ampacities
Free Air
40°C
A
11.5
11.5
15
15
21
21
28
28
36
50
66
Minimum
Insulation
Resistance
at 70°C
M - km
0.0141
0.0135
0.0123
0.0116
0.0102
0.0093
0.0094
0.0085
0.0073
0.0069
0.0057
Cable
Weight
(approx)
kg / km
200
200
220
220
270
270
360
360
490
690
1,010
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE WITH GROUND
Application :Exposed wiring in air or use inraceway wet or dry location, directburial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction :Conductor : Annealed copper, solidor strandedSizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinylchloride (Gray, Black and Redcolour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistancepolyvinyl chloride (Black colour)
Outer sheath : Heat resistancepolyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Inner Sheath
PVC Outer Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200838
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
3 x 25/6 PD-NYY-G3 x 35/10 PD-NYY-G3 x 50/10 PD-NYY-G3 x 70/10 PD-NYY-G3 x 95/16 PD-NYY-G3 x 120/16 PD-NYY-G3 x 150/25 PD-NYY-G3 x 185/25 PD-NYY-G3 x 240/35 PD-NYY-G3 x 300/35 PD-NYY-G
Nominal
Sectional
Area
mm2
25
35
50
70
95
120
150
185
240
300
Nominal
Sectional
Area
mm2
6
10
10
10
16
16
25
25
35
35
Phase core
Number &
Diameter
of Wire
No. / mm
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
Ground core
Number &
Diameter
of Wire
No. / mm
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/2.14
7/2.14
19/1.53
19/1.53
Thickness
of
Insulation
mm
1.3
1.3
1.5
1.5
1.7
1.7
1.9
2.1
2.3
2.5
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
300/R
300/R
300/R
300/R
300/R
200/R
200/R
150/R
150/R
Overall
Diameter
mm
31.0
34.0
36.0
40.5
46.0
50.5
56.0
61.5
69.0
76.0
Thickness
of Inner
Sheath
mm
1.2
1.2
1.5
1.5
1.5
1.8
1.8
2.0
2.0
2.2
Thickness
of Outer
Sheath
mm
2.0
2.0
2.2
2.2
2.4
2.6
2.8
3.0
3.2
3.4
Allowable
Ampacities
Free Air
40°C
A
84
104
125
160
194
225
256
297
351
404
Minimum
Insulation
Resistance
at 70°C
M - km
0.0054
0.0047
0.0046
0.0039
0.0038
0.0034
0.0034
0.0034
0.0033
0.0032
Cable
Weight
(approx)
kg / km
1,410
1,820
2,510
3,170
4,280
5,280
6,460
7,980
10,250
12,600
Application :Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Redcolour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE WITH GROUND
Phase Conductor
Ground Conductor
PVC Insulation
PVC Inner Sheath
PVC Outer Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 39
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
4 x 1/1 PD-NYY-G4 x 1/1 PD-NYY-G4 x 1.5/1 PD-NYY-G4 x 1.5/1 PD-NYY-G4 x 2.5/1.5 PD-NYY-G4 x 2.5/1.5 PD-NYY-G4 x 4/2.5 PD-NYY-G4 x 4/2.5 PD-NYY-G4 x 6/4 PD-NYY-G4 x 10/4 PD-NYY-G4 x 16/6 PD-NYY-G
Nominal
Sectional
Area
mm2
1
1
1.5
1.5
2.5
2.5
4
4
6
10
16
Nominal
Sectional
Area
mm2
1
1
1
1
1.5
1.5
2.5
2.5
4
4
6
Phase core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
1/2.25
7/0.85
7/1.04
7/1.35
7/1.70
Ground core
Number &
Diameter
of Wire
No. / mm
1/1.13
7/0.40
1/1.13
7/0.40
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/0.85
7/1.04
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.1
1.1
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
14.0
14.5
15.0
15.5
16.0
17.0
18.0
19.0
20.5
25.0
28.5
Thickness
of Inner
Sheath
mm
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.2
Thickness
of Outer
Sheath
mm
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
1.8
2.0
2.0
Allowable
Ampacities
Free Air
40°C
A
11.5
11.5
15
15
21
21
28
28
36
50
66
Minimum
Insulation
Resistance
at 70°C
M - km
0.0141
0.0135
0.0123
0.0116
0.0102
0.0093
0.0094
0.0085
0.0073
0.0069
0.0057
Cable
Weight
(approx)
kg / km
230
230
260
260
330
330
440
440
600
880
1,260
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, THREE CORE WITH GROUND
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE WITH GROUND
Application :Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray, Black, Red and Blue colour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Inner Sheath
PVC Outer Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200840
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
4 x 25/6 PD-NYY-G4 x 35/10 PD-NYY-G4 x 50/10 PD-NYY-G4 x 70/10 PD-NYY-G4 x 95/16 PD-NYY-G4 x 120/16 PD-NYY-G4 x 150/25 PD-NYY-G4 x 185/25 PD-NYY-G4 x 240/35 PD-NYY-G4 x 300/35 PD-NYY-G
Nominal
Sectional
Area
mm2
25
35
50
70
95
120
150
185
240
300
Nominal
Sectional
Area
mm2
6
10
10
10
16
16
25
25
35
35
Phase core
Number &
Diameter
of Wire
No. / mm
7/2.14
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
Ground core
Number &
Diameter
of Wire
No. / mm
7/1.04
7/1.35
7/1.35
7/1.35
7/1.70
7/1.70
7/2.14
7/2.14
19/1.53
19/1.53
Thickness
of
Insulation
mm
1.3
1.3
1.5
1.5
1.7
1.7
1.9
2.1
2.3
2.5
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
300/R
300/R
300/R
300/R
300/R
300/R
200/R
200/R
150/R
150/R
Overall
Diameter
mm
33.5
38.5
43.5
44.5
51.5
56.0
62.0
68.0
76.5
84.5
Thickness
of Inner
Sheath
mm
1.2
1.5
1.5
1.5
1.8
1.8
2.0
2.0
2.2
2.2
Thickness
of Outer
Sheath
mm
2.0
2.2
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.8
Allowable
Ampacities
Free Air
40°C
A
84
104
125
160
194
225
256
297
351
404
Minimum
Insulation
Resistance
at 70°C
M - km
0.0054
0.0047
0.0046
0.0039
0.0038
0.0034
0.0034
0.0034
0.0033
0.0032
Cable
Weight
(approx)
kg / km
1,790
2,390
3,180
4,060
5,550
6,770
8,340
10,240
13,230
16,280
PHELPS DODGE CONDUCTOR TYPE PD-NYY-G (MEA TYPE C-GRD) 750 V 70oC PVC INSULATED AND DOUBLE SHEATHED, FOUR CORE WITH GROUND
Application :Exposed wiring in air or use in raceway wet or dry location, direct burial in ground.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 14
Construction : Conductor : Annealed copper, solid or stranded Sizes 1 mm2 up to 300 mm2 (Phase)Sizes 1 mm2 up to 35 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray, Black, Red and Blue colour) Phase, (Green with Yellow Stripe colour) Ground.
Inner sheath : Heat resistance polyvinyl chloride (Black colour)
Outer sheath : Heat resistance polyvinyl chloride (Black colour)
Phase Conductor
Ground Conductor
PVC Insulation
PVC Inner Sheath
PVC Outer Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 41
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
2 x 1/1 PD-VCT-G2 x 1.5/1 PD-VCT-G2 x 2.5/1.5 PD-VCT-G2 x 4/2.5 PD-VCT-G2 x 6/4 PD-VCT-G2 x 10/4 PD-VCT-G2 x 16/6 PD-VCT-G2 x 25/6 PD-VCT-G2 x 35/10 PD-VCT-G
Nominal
Sectional
Area
mm2
1
1.5
2.5
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1.5
2.5
4
4
6
6
10
Phase core
Min Number &
Diameter
of Wire
No. / mm
32/0.21
30/0.26
50/0.26
56/0.31
84/0.31
80/0.41
126/0.41
196/0.41
276/0.41
Ground core
Number &
Diameter
of Wire
No. / mm
32/0.21
32/0.21
30/0.26
50/0.26
56/0.31
56/0.31
84/0.31
84/0.31
80/0.41
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.3
1.3
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
10.5
11.5
13.0
15.5
17.0
20.0
23.0
27.5
31.0
Thickness
of
Sheath
mm
1.2
1.4
1.4
1.6
1.6
1.8
2.2
2.4
2.6
Allowable
Ampacities
Free Air
40°C
A
13
17
23
30
40
55
74
97
120
Minimum
Insulation
Resistance
at 70°C
M - km
0.0127
0.0111
0.0092
0.0084
0.0071
0.0068
0.0050
0.0048
0.0041
Cable
Weight
(approx)
kg / km
110
130
170
250
320
520
730
1,030
1,410
Application :For mobile-electrical equipment used in mines, factories, farm or household appliances. Also for heavy-duty service such as heavy tools, garage portable lights, and battery chargers.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 15
Construction : Conductor : Annealed copper, bunch or strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray and Black colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE TWO CORE WITH GROUND
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200842
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
3 x 1/1 PD-VCT-G3 x 1.5/1 PD-VCT-G3 x 2.5/1.5 PD-VCT-G3 x 4/2.5 PD-VCT-G3 x 6/4 PD-VCT-G3 x 10/4 PD-VCT-G3 x 16/6 PD-VCT-G3 x 25/6 PD-VCT-G3 x 35/10 PD-VCT-G
Nominal
Sectional
Area
mm2
1
1.5
2.5
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1.5
2.5
4
4
6
6
10
Phase core
Min Number &
Diameter
of Wire
No. / mm
32/0.21
30/0.26
50/0.26
56/0.31
84/0.31
80/0.41
126/0.41
196/0.41
276/0.41
Ground core
Number &
Diameter
of Wire
No. / mm
32/0.21
32/0.21
30/0.26
50/0.26
56/0.31
56/0.31
84/0.31
84/0.31
80/0.41
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.3
1.3
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
11.5
12.5
14.5
17.0
19.0
23.5
27.5
32.5
36.5
Thickness
of
Sheath
mm
1.4
1.4
1.4
1.6
1.8
2.0
2.4
2.6
2.8
Allowable
Ampacities
Free Air
40°C
A
11.5
15
21
28
36
50
66
84
104
Minimum
Insulation
Resistance
at 70°C
M - km
0.0127
0.0111
0.0092
0.0084
0.0071
0.0068
0.0050
0.0048
0.0041
Cable
Weight
(approx)
kg / km
140
160
210
310
420
680
950
1,350
1,860
Application :For mobile-electrical equipment used in mines, factories, farm or household appliances. Also for heavy-duty service such as heavy tools, garage portable lights, and battery chargers.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 15
Construction : Conductor : Annealed copper, bunch stranded Sizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour) Phase, (Green with Yellow Stripe colour) Ground.
Sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE WITH GROUND
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 43
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
4 x 1/1 PD-VCT-G4 x 1.5/1 PD-VCT-G4 x 2.5/1.5 PD-VCT-G4 x 4/2.5 PD-VCT-G4 x 6/4 PD-VCT-G4 x 10/4 PD-VCT-G4 x 16/6 PD-VCT-G4 x 25/6 PD-VCT-G4 x 35/10 PD-VCT-G
Nominal
Sectional
Area
mm2
1
1.5
2.5
4
6
10
16
25
35
Nominal
Sectional
Area
mm2
1
1
1.5
2.5
4
4
6
6
10
Phase core
Min Number &
Diameter
of Wire
No. / mm
32/0.21
30/0.26
50/0.26
56/0.31
84/0.31
80/0.41
126/0.41
196/0.41
276/0.41
Ground core
Number &
Diameter
of Wire
No. / mm
32/0.21
32/0.21
30/0.26
50/0.26
56/0.31
56/0.31
84/0.31
84/0.31
80/0.41
Thickness
of
Insulation
mm
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.3
1.3
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Standard
Packing
m
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
500/R
Overall
Diameter
mm
13.0
13.5
16.0
18.5
21.0
26.0
30.5
36.0
40.5
Thickness
of
Sheath
mm
1.6
1.6
1.6
1.8
2.0
2.2
2.6
2.8
3.1
Allowable
Ampacities
Free Air
40°C
A
11.5
15
21
28
36
50
66
84
104
Minimum
Insulation
Resistance
at 70°C
M - km
0.0127
0.0111
0.0092
0.0084
0.0071
0.0068
0.0050
0.0048
0.0041
Cable
Weight
(approx)
kg / km
180
210
280
400
530
1,080
1,280
1,810
2,430
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE THREE CORE WITH GROUND
Application :For mobile-electrical equipment used in mines, factories, farm or household appliances. Also for heavy-duty service such as heavy tools, garage portable lights, and battery chargers.
Classification :Maximum conductor temperature 70oC Circuit voltage does not ex-ceed 750 volts.
Reference Standard :TIS 11-2531 TABLE 15
Construction : Conductor : Annealed copper, bunch or strandedSizes 1 mm2 up to 35 mm2 (Phase)Sizes 1 mm2 up to 10 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride (Gray, Black, Red and Blue colour) Phase, (Green with Yellow Stripe colour) Ground
Sheath : Heat resistance polyvinyl chloride (Black colour)
PHELPS DODGE CONDUCTOR TYPE PD-VCT-G 750 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE FOUR CORE WITH GROUND
Phase Conductor
Ground Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200844
C = Packing in coilR = Packing in reel
Application :In dry room for connection of portable appliance where mechanical stresses are low (e.g. radio sets etc.) not for heating appliances. The ground conductor is provided for grounding of those appliances with electrical supply system.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 16
Construction : Conductor : Annealed copper, bunch stranded Sizes 1 mm2 up to 2.5 mm2 (Phase)Sizes 1 mm2 up to 1.5 mm2 (Ground)
Insulation : Heat resistance polyvinyl chloride(Any colour as requested)
PHELPS DODGE CONDUCTOR TYPE PD-VFF-G 300 V 70oC PVC INSULATED FLAT TYPE, FLEXIBLE TWO CORE WITH GROUND
PHELPS DODGE
TYPE LETTER
2 x 1/1 PD-VFF-G2 x 1.5/1 PD-VFF-G2 x 2.5/1.5 PD-VFF-G
Nominal
Sectional
Area
mm2
1
1.5
2.5
Nominal
Sectional
Area
mm2
1
1
1.5
Phase core
Min Number &
Max Diameter
of Wire
No. / mm
32/0.21
30/0.26
50/0.26
Ground core
Min Number &
Max Diameter
of Wire
No. / mm
32/0.21
32/0.21
30/0.26
Thickness
of
Insulation
mm
0.8
0.8
0.8
Thickness
of
Insulation
mm
0.6
0.6
0.6
Standard
Packing
m
100/C
100/C
100/C
Overall
Diameter
mm
3.6 x 9.8
3.9 x 10.5
4.8 x 12.5
Allowable
Ampacities
Free Air
40°C
A
16
21
29
Minimum
Insulation
Resistance
at 70°C
M - km
0.0127
0.0111
0.0092
Cable
Weight
(approx)
kg / km
50
60
90
Phase Conductor
Ground Conductor
PVC Insulation
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 45
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
2 x 0.5 PD-VAFF2 x 0.5 PD-VAFF2 x 1 PD-VAFF2 x 1.5 PD-VAFF2 x 2.5 PD-VAFF2 x 4 PD-VAFF2 x 6 PD-VAFF2 x 10 PD-VAFF2 x 16 PD-VAFF2 x 25 PD-VAFF2 x 35 PD-VAFF
Nominal
Sectional
Area
mm2
0.5
0.5
1
1.5
2.5
4
6
10
16
25
35
Phase core
Min Number &
Max Diameter
of Wire
No. / mm
16/0.21
28/0.16
32/0.21
30/0.26
50/0.26
56/0.31
84/0.31
80/0.41
126/0.41
196/0.41
276/0.41
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.2
1.2
Standard
Packing
m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
100/C
500/R
500/R
Overall
Diameter
mm
4.7 x 7.2
4.7 x 7.2
5.2 x 8.0
6.2 x 9.4
7.2 x 11.5
8.0 x 13.0
8.8 x 14.5
10.5 x 17.5
12.0 x 20.5
14.5 x 25.0
16.0 x 28.0
Thickness
of
Sheath
mm
0.9
0.9
0.9
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
Allowable
Ampacities
Free Air
40°C
A
8
8
13
17
23
30
40
55
74
97
120
Minimum
Insulation
Resistance
at 70°C
M - km
0.0132
0.0133
0.0104
0.0090
0.0083
0.0076
0.0065
0.0057
0.0047
0.0045
0.0038
Cable
Weight
(approx)
kg / km
37
37
50
70
100
140
200
300
440
690
900
PHELPS DODGE CONDUCTOR TYPE PD-VFF-G 300 V 70oC PVC INSULATED FLAT TYPE, FLEXIBLE TWO CORE WITH GROUND
Application :For surface or above ceiling wiring or direct embeded in plaster.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 17
Construction : Conductor : Annealed copper, bunch strandedSizes 0.5 mm2 up to 35 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, and Black colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
PHELPS DODGE CONDUCTOR TYPE PD-VAFF 300 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE, FLAT TYPE, TWO CORE
Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200846
C = Packing in coilR = Packing in reel
PHELPS DODGE
TYPE LETTER
3 x 0.5 PD-VAFF3 x 0.5 PD-VAFF3 x 1 PD-VAFF3 x 1.5 PD-VAFF3 x 2.5 PD-VAFF3 x 4 PD-VAFF3 x 6 PD-VAFF3 x 10 PD-VAFF3 x 16 PD-VAFF
Nominal
Sectional
Area
mm2
0.5
0.5
1
1.5
2.5
4
6
10
16
Number &
Max Diameter
of Wire
No. / mm
16/0.21
28/0.16
32/0.21
30/0.26
50/0.26
56/0.31
84/0.31
80/0.41
126/0.41
Thickness
of
Insulation
mm
0.6
0.6
0.6
0.6
0.7
0.8
0.8
0.9
1.0
Standard
Packing
m
100/C
100/C
100/C
100/C
100/C
100/C
100/C
500/R
500/R
Overall
Diameter
mm
4.7 x 9.6
4.7 x 9.6
5.2 x 11.0
6.2 x 12.5
7.2 x 16.0
8.0 x 18.5
8.8 x 20.5
10.5 x 25.0
12.5 x 29.0
Thickness
of
Sheath
mm
0.9
0.9
0.9
1.2
1.2
1.2
1.2
1.2
1.4
Allowable
Ampacities
Free Air
40°C
A
6.5
6.5
11.5
15
21
28
36
50
66
Minimum
Insulation
Resistance
at 70°C
M - km
0.0132
0.0133
0.0104
0.0090
0.0083
0.0076
0.0065
0.0057
0.0047
Cable
Weight
(approx)
kg / km
41
41
55
77
110
154
220
363
484
Application :Building wiring, for installation on insulator or in raceway, dry and wet location.
Classification :Maximum conductor temperature 70oC Circuit voltage does not exceed 300 volts.
Reference Standard :TIS 11-2531 TABLE 17
Construction : Conductor : Annealed copper,bunch stranded Sizes 0.5 mm2 up to 16 mm2
Insulation : Heat resistance polyvinyl chloride (Gray, Black and Red colour)
Sheath : Heat resistance polyvinyl chloride (White colour)
PHELPS DODGE CONDUCTOR TYPE PD-VAFF 300 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE, FLAT TYPE, THREE CORE
Conductor
PVC Insulation
PVC Sheath
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 47
Application :general purpose building wire forinstallation in air, duct, conduit orother raceways.
Classification :600 V rating, maximum conductortemperature 90oC both wet anddry locations.
Reference Standard :UL 44
Construction : Conductor : Compact strandedaluminum alloy 800 series per ASTM B-801
Insulation : UL recognized cross-linked polyethylene
**Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30 C perTable 310-16 of the 1990 National Electrical Code (NFPA 70-1990).
O
XHHW-2
SIZE
(AWG
or kcmil)
6421
1/02/04/0250300350400500600750
1000
Conductor
diameter
mm
4.3
5.4
6.8
7.6
8.5
9.6
12.1
13.2
14.5
15.6
16.7
18.7
20.7
23.1
26.9
Insulation
thickness
mm
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
2.03
2.03
2.03
Approx.
Outside
Diameter
mm
6.8
7.9
9.3
10.7
11.6
12.6
15.2
16.8
18.1
19.2
20.3
22.3
25.2
27.6
31.4
Approx.
Cable
Weight
kg/km
63
91
133
172
209
253
380
456
535
614
691
848
1039
1270
1655
Ampacities**
60
75
100
115
135
150
205
230
255
280
305
350
385
435
500
PHELPS DODGE CONDUCTOR TYPE PD-VAFF 300 V 70oC PVC INSULATED AND SHEATHED, FLEXIBLE, FLAT TYPE, THREE CORE
Aluminum Alloy Conductor
UL Recognized Cross-Linked Polyethylene
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 200848
**Ampacities for not more than three conductors in raceway or cable or earth (directly buried), based on ambient temperature of 30 C perTable 310-16 of the 1990 National Electrical Code (NFPA 70-1990).
O
Application :General purpose building wire for installation in air duct, conduitor other raceways.
Classification :600 V rating, maximum conductortemperature 75
oC wet or 90
oC dry
location for XHHW and 90oC both
wet and dry location for XHHW-2
Reference :UL 44
Construction : Conductor : Solid or concentricstranded (class B) copper per ASTMB-3 or ASTM B-8 and UL 44
Insulation : UL recognized cross-linked polyethylene
XHHW , XHHW-2
SIZE
(AWG
or kcmil)
14121014121086421
1/02/04/0250300350400500600750
1000
No./Wire
Size
mm
1/1.63
1/2.05
1/2.59
7/0.62
7/0.77
7/0.98
7/1.24
7/1.56
7/1.96
7/2.47
19/1.69
19/1.89
19/2.12
19/2.68
37/2.09
37/2.29
37/2.47
37/2.64
37/2.95
61/2.52
61/2.82
61/3.25
Insulation
thickness
mm
0.76
0.76
0.76
0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.40
1.40
1.40
1.40
1.65
1.65
1.65
1.65
1.65
2.03
2.03
2.03
Approx.
Outside
Diameter
mm
3.3
3.7
4.3
3.5
4.0
4.6
6.2
7.2
8.4
9.9
11.5
12.5
13.7
16.5
18.3
19.7
20.9
22.1
24.3
27.1
29.8
33.7
Approx.
Cable
Weight
kg/km
30
40
60
30
45
65
105
155
235
360
450
560
695
1080
1280
1520
1765
2005
2485
2995
3715
4910
Ampacities**
Dry
90 C
15
20
30
15
20
30
55
75
95
130
150
170
195
260
290
320
350
380
430
475
535
615
oWet
75 C
15
20
30
15
20
30
50
65
85
115
130
150
175
230
255
285
310
335
380
420
475
545
o
Copper conductor
UL Recognized Cross-Linked Polyethylene
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008 49
Scope :This specification covers single conductor cables having polyvinylchloride (PVC) insulation with andoverall nylon jacket.
Cables conform to the following standards :UL-83 for Thermoplastic InsulatedWireUL-758 for Appliance Wiring MaterialsUL-1063 for Machine Tool Wire(stranded conductors only)Federal specifications J-C-30B
Application :- General purpose building wire for services, feeders and branch circuits- Conduit and raceways- 1/0 and larger for cable tray use
Product construction conductor :- Bare annealed copper per ASTM B-3 - Stranded conductors per ASTM B-8or 787
Insulation :- Color coded premium grade flameretardant PVC (polyvinyl chloride)
Jacket : - Tough polyamide nylon- Temperature rating not to exceed :THHN : 90oC dry, and drap, 600VTHWN : 75oC dry, wet or in oil, 600 VMTW : 90oC dry, 80oC in oil, 600 VAWM : 90oC dry, 80oC in oil, 1000 VAWM : 105oC dry, 75oC in oil, 600 V
Packaging : - 14 and 12 AWG : 4x500 in a cartonor 2500’ reels- 10 AWG : 2x500’ in a carton or 2500’reels , and cut to order- 1 AWG and larger : 500’ and 1000’reels, and cut to order.
Color: Black, white, red, green, yellow, blue, orange, gray, purple, pink, tan
TYPE THHN - THWN PVC INSULATION WITH NYLON JACKET14 AWG - 1000 MCM 600V GASOLINE AND OIL, RESISTANT VW-1
Solid or stranded bare copper
PVC Insulation
Nylon jacket
SIZE(AWG
ORMCM)
14
12
10
14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0
250
300
350
400
500
600
750
1000
solid
soild
soild
19
19
19
19
19
19
19
19
19
19
19
19
19
37
37
37
37
37
61
61
61
0.004
0.004
0.004
0.004
0.004
0.004
0.005
0.005
0.006
0.006
0.006
0.007
0.007
0.007
0.007
0.007
0.008
0.008
0.008
0.008
0.008
0.009
0.009
0.009
C
C
C
C
C
C
C
C
B
B
B
B
B
B
B
B
B
B
B
B
B
0.105
0.122
0.153
0.112
0.129
0.162
0.214
0.252
0.323
0.349
0.381
0.439
0.481
0.523
0.573
0.628
0.705
0.758
0.809
0.851
0.935
1.031
1.136
1.289
16
24
37
17
25
39
65
98
157
194
240
305
379
470
584
728
868
1030
1193
1354
1679
2023
2508
3242
0.015
0.015
0.020
0.015
0.015
0.020
0.030
0.030
0.040
0.040
0.040
0.050
0.050
0.050
0.050
0.050
0.060
0.060
0.060
0.060
0.060
0.070
0.070
0.070
Ampacity
15
20
30
15
20
30
50
65
85
100
115
130
150
175
200
230
255
286
310
335
380
420
475
545
15
20
30
15
20
30
65
75
95
110
130
150
170
195
225
280
290
320
350
380
430
475
535
615
-
-
-
16
20
30
40
55
70
80
95
110
125
145
165
185
215
240
280
280
320
355
400
455
S500/R2500
S500/R2500
S500/R2500
S500/R2500
S500/R2500
S500/R2500
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
R500/R1000
-
Strand
Class
NO.OFStrands
PVCInsulthick
(inches)
NylonJacketthick
(inches)
ApproxOutsideDiameter(inches)
THWN75 C
THHN90 C
MTW90 C
Approxweight100FTpound
Standard
PUT-UP
Phelps Dodge International (Thailand) LimitedManeeya Center Building, 16th Floor, 518/5 Ploenchit Rd., Lumpini, Pathumwan, Bangkok 10330 Telephone : (66 2) 680 5800 Fax : (66 2) 680 5896, 680 5898 Website : www.pdic.com
Building Wires and Interior WiringRevision 2 : July 16, 2008
AEIC ASSOCIATIONOFEDISONILLUMINATINGCOMPANIESAS/NZS AUSTRALIAN/NEWZEALANDSTANDARDANS/EIA AMERICANNATIONALSTANDARD ELECTRONICINDUSTRIESASSOCIATIONANSI/IEEE AMERICANNATIONALSTANDARD THEINSTITUREOFELECTRICALANDELECTRONICSENGINEERSANSI/TIA/EIA AMERICANNATIONALSTANDARD TELECOMMUNICATIONSASSOCIATION ELECTRONICINDUSTRIESASSOCIATIONAS AUSTRALIANSTANDARDASTM AMERICANSOCIETYFORTESTINGANDMATERIALSBELLCORE BELLCOREBS BRITISHSTANDARDDIN DEUTSCHERINSTRTUTFORNORMUNGEV.BERLINEGAT ELECTRICITYGENERATINGAUTHORITYOFTHAILANDFAA FEDERALAVIATIONADMINISTRATIONHK HONGKONGTELECOMMUNICATIONSICEA INSULATEDCABLESENGINEERSASSOCIATIONANSI/ICEA AMERICANNATIONALSTANDARD INSULATEDCABLESENGINEERSASSOCIATIONNEMA/ICEA NATIONALELECTRICALMANUFACTURERSASSOCIATION INSULATEDCABLESENGINEERSASSOCIATIONIPCEA INSULATEDPOWERCABLESENGINEERSASSOCIATIONIEC INTERNATIONALELECTRICALCOMMISSIONICEE THEINSTITUTEOFELECTRICALANDELECTRONICSENGINEERS,INC.ISO INTERNATIONALORGANIZATIONFORSTANDARDIZATIONJIS JAPANESEINDUSTRIALSTANDARDMEA METROPOLITANELECTRICITYAUTHORITYNEMA NATIONALELECTRICALMANUFACTURERSASSOCIATIONNFPA NATIONALFIREPROTECTIONASSOCIATIONPEA PROVINCIALELECTRICITYAUTHORITYREA RURALELECTRIFICATIONADMINISTRATIONSABS SOUTHAFRICANSTANDARDTIS THAIINDUSTRIALSTANDARDTOT TOTPUBLICCOMPANYLIMITEDUL UNDERWRITERSLABORATORIES
ALL WIRE & CABLES MANUFACTURED BY PHELPS DODGE INTERNATIONAL (THAILAND) LIMITED. ARE QUALITY TESTED & CONFORM WITH THE FOLLOWING STANDARDS:
50
Address and Contact PointSales and Executive Office:518/5 Maneeya Center Bldg., 16 Fl. Ploenchit Rd.,
Lumpinee, Pathumwan, Bangkok 10330 Thailand
Tel : (662) 680 5800
Fax : (662) 680 5896, 680 5898
Website: www.pdic.com
Bangplee Factory :159 Moo 10, Soi Watraburana, Theparak., Rd., Km. 17
Bangpla, Bangplee, Samut Prakarn 10540 Thailand.
Tel : (662) 769 2400
Fax : (662) 769 2440
Rayong Factory: 9/9 Moo4, Tambol Nikompattana,
Ampur Nikompattana, Rayong 21180 Thailand
Tel : (66) 038 877 155 (Auto 10 Lines)
Fax : (66) 038 877 166