buffalo data storage expansion june 2015 1. as organizations grow the amount of data storage...

38
Buffalo Data Storage Expansion June 2015 1

Upload: grace-hamilton

Post on 27-Dec-2015

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

Buffalo Data Storage Expansion

June 2015

1

Page 2: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

• As organizations grow the amount of data storage capacity required to support it grows as well• Increased data retention requirements• Increased headcount• New applications

• Adding on to an existing storage network should have minimal impact on the end user

• Mission critical data should have backups or redundancies in place in the event of an unforeseen disaster

2

Overview

Page 3: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

• The TeraStation™ line of network storage devices represents Buffalo's premier NAS and iSCSI unified storage solutions

• Designed to exacting standards and made for the demanding needs of today's businesses

• High availability storage technologies• RAID• Hot-spare

• In a Windows (Storage) Server 2012 environment, TeraStation™ is a cost-effective network storage expansion solution for businesses that value performance and reliability

3

Overview (cont.)

Page 4: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

• Single logical volume• Available redundancies • TeraStation™ RAID (1, 5, 6, 10, 51, 61)• Protects against physical HDD failures

• Microsoft Storage Services Virtual Disk Storage Layout (Mirror or Parity)• Protects against a chassis failure (ex. fire, flood, etc.)

4

D:/

Windows Server 2012 orWindows Storage Server 2012

Option 1 - Multiple layers of data protection

Switch (i.e. Buffalo BS-GUP)

Buffalo TeraStation™(i.e. TeraStation™ 7120r)

Page 5: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

D:/ E:/ F:/

Option 2 - Most storage capacity

• Multiple logical volumes• Available redundancies • TeraStation™ RAID (1, 5, 6, 10, 51, 61)• Protects against HDD drive failures

5

Buffalo TeraStation™(i.e. TeraStation™ 7120r)

Switch (i.e. Buffalo BS-GUP)

Windows Server 2012 orWindows Storage Server 2012

Page 6: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

The following procedure explains how to expand data storage capacity on an existing Windows (Storage) Server 2012 environment

by configuring multiple Buffalo Terastation™ into a single logical volume (Option 1)

6

Comments in blue are specific for configuring multiple Buffalo Terastation™ into multiple logical volumes (Option 2)

Page 7: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

7

• Create iSCSI targets• Connect iSCSI targets to Windows Server 2012• Add iSCSI targets to storage pool• Create a virtual disk from a storage pool• Create a logical volume from a logical disk

TeraStation™

Windows Server

Step 1

Page 8: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

http://buffalotech.com/support-and-downloads/faqs/creating-an-iscsi-target-on-a-buffalo-terastation

8

Creating a TeraStation™ iSCSI target

Page 9: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

9

• Create iSCSI targets• Connect iSCSI targets to Windows Server 2012• Add iSCSI targets to storage pool• Create a virtual disk from a storage pool• Create a logical volume from a logical disk

TeraStation™

Windows Server

Step 2

Page 10: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

1. In “Control Panel” open the “iSCSI Initiator”

10

2. Select iSCSI target then click “Connect”

Connecting iSCSI targets

Page 11: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

3. Check both check boxes, then click “OK”

11

4. iSCSI target status should now be “Connected”

Connecting iSCSI targets (cont.)

Page 12: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

5. Repeat connection process for all TeraStation™ iSCSI targets

12

Connecting iSCSI targets (cont.)

Page 13: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

13

• Create iSCSI targets• Connect iSCSI targets to Windows Server 2012• Add iSCSI targets to storage pool• Create a virtual disk from a storage pool• Create a logical volume from a logical disk

TeraStation™

Windows Server

Step 3

Page 14: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

1. Open “Sever Manager” then click “File and Storage Services”

14

2. Click “Storage Pools”

Adding iSCSI targets to storage pool

Page 15: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

15

3. Click “Storage Pools”

Adding iSCSI targets to storage pool

Page 16: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

16

Adding iSCSI targets to storage pool (cont.)

4. The iSCSI targets should be visible in the “Physical Disks” area

4a. If iSCSI targets are not seen under “Physical Disks” click the refresh icon

Page 17: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

17

Adding iSCSI targets to storage pool (cont.)

5. Right-click iSCSI target and select “New Storage Pool…”- This will open the “Storage Pool Wizard”

Page 18: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

7. Click “Next”

18

8. Specify pool name

9. Click “Next”

Adding iSCSI targets to storage pool (cont.)

Page 19: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

10. Select physical disks for storage pool

- For Option 2 (creating multiple logical volumes) select only one disk

19

11. Check properties then click “Create”

Adding iSCSI targets to storage pool (cont.)

Page 20: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

12. Check results then click “Close”

20

13. New storage pool is visible in the “Storage Pools” window

Adding iSCSI targets to storage pool (cont.)

Page 21: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

21

• Create iSCSI targets• Connect iSCSI targets to Windows Server 2012• Add iSCSI targets to storage pool• Create a virtual disk from a storage pool• Create a logical volume from a logical disk

TeraStation™

Windows Server

Step 4

Page 22: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

1. Select the new storage pool that was created

2. Right-click and select “New Virtual Disk”

- This will open the Virtual Disk Wizard

22

Creating virtual disk from storage pool

Page 23: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

2. Click “Next”

23

3. Select “Pool Name” then click “Next”

Creating virtual disk from storage pool (cont.)

Page 24: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

4. Create virtual disk name

24

5. Select storage layout type

- Refer to Appendix A

Creating virtual disk from storage pool (cont.)

Page 25: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

6. Select provisioning type

25

Creating virtual disk from storage pool (cont.)

7. Select size of virtual disk

Page 26: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

8. Check properties then click “Create”

26

9. Check results then click “Close”

Creating virtual disk from storage pool (cont.)

Page 27: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

27

10. Virtual disk created

Creating virtual disk from storage pool (cont.)

Page 28: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

28

• Create iSCSI targets• Connect iSCSI targets to Windows Server 2012• Add iSCSI targets to storage pool• Create a virtual disk from a storage pool• Create a logical volume from a logical disk

TeraStation™

Windows Server

Step 5

Page 29: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

1. Select the new Virtual Disk that was created

2. Right Click and select “New Volume…”

- New Volume Wizard will open

29

Creating a volume from a virtual disk

Page 30: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

3. Click “Next”

30

4. Select the new virtual disk that was just created

5. Click “Next”

Creating a volume from a virtual disk (cont.)

Page 31: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

6. Specify volume size

31

7. Select desired drive letter

Creating a volume from a virtual disk (cont.)

Page 32: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

8. Select desired file system

32

Creating a volume from a virtual disk (cont.)

9. Check settings then click “Create”

Page 33: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

10. Check results then click “Close”

33

11. Under “virtual disk” new drive letter will be available

Creating a volume from a virtual disk (cont.)

Page 34: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

• Logical volume created• New volume can be seen in Windows Explorer • For Option 2 (creating multiple volumes) repeat process from slide 16 for

other TeraStations (iSCSI targets), and assign new drive letter.

34

Creating a volume from a virtual disk (cont.)

Page 35: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

Future Expansion

35

Page 36: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

• Flexible future storage expansion

• Additional TeraStation™ can be added on • To increase capacity of an existing logical volume• As a new logical volume

36

Future Expansion

Page 37: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

Appendix

37

Page 38: Buffalo Data Storage Expansion June 2015 1. As organizations grow the amount of data storage capacity required to support it grows as well Increased data

38

Storage LayoutWhile creating a virtual disk based on a storage pool form Server Manager/File and Storage Services/Volumes/Storage Pools, there are three levels of software RAID available as illustrated below. These RAID settings are presented as options of Windows Server 2012 Storage Layout including:

• Simple - This is a stripe set without parity or mirroring by striping data across multiple disks, similar to RAID 0. Compared with a single disk, this configuration increases throughput and maximizes capacity. There is however no redundancy and it does not protect data from a disk failure.• Mirror - This is a mirror set without striping or parity by duplicating data on two or three disks, similar to RAID 1. It increases reliability with reduced capacity. This configuration requires at least two disks to protect data from a single disk failure, or at least five disks to protest from two simultaneous disk failure.• Parity - This is a striped set with distributed parity by striping data and parity information across multiple disks, similar to RAID 5. It increases reliability with reduced capacity. This configuration requires at least three disks to protect data from a single disk failure, and cannot be used in a failover cluster.

- See more at: http://blogs.technet.com/b/yungchou/archive/2012/08/31/windows-server-2012-storage-virtualization-explained.aspx#sthash.vQPhe9bM.dpuf

http://blogs.technet.com/b/yungchou/archive/2012/08/31/windows-server-2012-storage-virtualization-explained.aspx

Appendix A