BTS POWERSAFE

Using the Belotti BTS POWERSAFE solution your AC Connected units, such as rectifiers, Inverter and air condition units, will continue operating even during extreme mains voltage variation without need for the back-up generator to switch-on and, furthermore, thanks to the Galvanic Isolation provided by the Isolation transformer all the site will be totally protected from any Mains problem as well as protected from surges and spikes by our three poles Surge Protection. Working hours of back-up generators will dramatically decrease. Our Solution for Telecom is the result of the experience we gained in years of operation all over Africa working in partnership with the most important Telecom companies allowing our product to meet their stringent requirements in spite of the environmental difficulties. The solution briefly is the integration of three of our products: A) Belotti Voltage Stabiliser (AVR) B) Belotti Ultra-Isolation transformer C) Belotti Surge Protection (TVSS)

A Large voltage variations can be harmful to many ACunits, causing temporary or definite shut down and By-passing the Loads to the Back-Up Generator. Wit the Belotti Stabiliser it is not just possible to protect your connected units, but you will maintain full operation! B Ultra-Isolation Transformer D/Y (Dyn11) guarantee the Best electrical Protection and noise filtering for your BTS. Belotti transformer design gives: Galvanic Isolation and screen Pri/Sec Increased Voltage Phase Equilibration Generation of new, clean Neutral at Secondary avoiding all problems caused by the mains neutral. Clean neutral is essential for the correct operation of Single-phase loads. C Belotti Surge Protection Module SLP class C connected at the Mains entrance with its high discharge Power (40kA 8/20 s) and low residual Voltage is completing the protection of the installation. Higher Discharge Modules or combined (B+C) Modules are available for special locations. Components can be supplied also separately. We can customize our BTS POWERSAFE to meet your needs and requirement. Designed and Manufactured in Italy

MAINS FEATURES:Wide voltage regulation range : 160-290V(Phase-N) 10 to 200kVA, three-phase 400/230V or 208/120V 50/60Hz 3 to 200kVA single phase and three/mono Indoor IP21construction (Rack 19 space save) or Outdoor IP54 construction (Fibreglass). - Emergency By-pass - Customized project

IP54 FIBERGLASS OUTDOOR CASE - FAN ASSISTED

IP21 HEAVY METAL INDOOR CASE SMALL FOOTPRINT

A

VOLTAGE STABILISER (AVR) WIDE INPUT WINDOW

C

SURGE PROTECTION

B

ULTRA ISOLATION TRANSFORMER

The Belotti BTS Powersafe is supplied in three different configurations in order to satisfy the different Telecom requirements. The Standard Input window is +/-25% The Standard Output stability is +/-1% THREE-PHASE (BTS POWERSAFE 3/3) Indoor or Outdoor SINGLE-PHASE (BTS POWERSAFE 1/1) Indoor or Outdoor THREE-MONO (BTS POWERSAFE 3/1) Indoor or Outdoor Input Three-phase/ Output single-phase Common features: Isolation Transformer Surge protection class C Voltage Monitory Relay Fast Response Customized Input windowRTB

SINGLE-PHASE MODEL

US T A B IL IS E D OUTPUT

IN P U T

ISO

AT M CC

S SINGLE PHASE WIRING DIAGRAM

V

TB AT CC M ISO

BOOSTER TRANSFORMER VARIABLE AUTOTRANSFORMER SOLID STATE CONTROL CIRCUIT SERVOMOTOR INSULATION TRANSFORMER

THREE-PHASE MODEL WITH INDEPENDENT REGULATION ON EACH PHASE

THREE-MONO MODELis the latest version implemented to satisfy the needs of some of our client affected by phase missing problem during operation. It can guarantee supply (single-phase) to the BTS even when one or two phases are missing thanks to the Belotti patented Voltage PHASE SELECTOR.

A) SERVO-MECHANICAL VOLTAGE STABILISER (AVR)Independent control on each phase that guarantee +/-1% stability (Phase-N). Servo Mechanical design has low maintenance and fast response (70V/sec).

B) ULTRA ISOTRANSFORMERBelotti Ultra-Isolation Transformers guarantee the best Mains Input protection and noise filtering at BTS Powersafe Input. FEATURES: Galvanic Isolation Primary / Secondary Isolating Screen Dyn11 Design giving Phase Equilibration and Creation of a New Neutral Noise Filtration

C) SURGE PROTECTION SLP The SLP-275 V/3 three polearrester guarantee the protection of low-voltage network and connected appliances against surge voltage induced with a lightning strike, against surge voltage from manipulations and failures in high-voltage networks, and against industrial surge voltage (arrester of class II IEC 61643-1 (DIN VDE 0675-6).

SLP-275V/3 SPD type 2-surge arrester Replaceable varistor module, visual fault signallingTECHNICAL DATA Nominal Voltage Maximum operating Voltage Nominal Discharge current (8/20 s)/pole Maximum Discharge current (8/20 s)/pole Voltage Protection Level Response Time Maximum overcurrent protection Degree of Protection Range of Operating Temperatures Mounting on Fault Indication Meets the requirements of Standard Un Uc in lmax Up ta SLP-275 V/3 230V AC 275V AC/350V DC 20 kA 40 kA 0,9 kV 1,2 kV 25 ns 35 kA 160 A gL/gG IP 20 -40C +80C DIN rail 35 mm Red Indication Field EN 61643-11 +A11

Voltage Protection Level @ l = 5k A (8/20 s) Up

Short-circuit proof at maximum overcurrent protection

Stabilisers AVR for Telecom BST powersafe BST powersafe PWM BTS powersafe EB

Stabilisers AVR Servo mechanical BST Electronic BST- EB

Variable autotransformers

El Core transformers

20135 MILANO - ITALY - P.ZA TRENTO, 6 - PHONE +39.02.58306849-58306732-58308956 - FAX +39.02.58304722E-mail: [email protected] - http://www.belotti.it