Technical Sheet TS-023-VA-Bypass-eng-eu March, 2008 Brooks ® ByPass Flowmeters DESIGN FEATURES • Low cost and maintenance. • Lineair to flow and output signals. • Rangeability up to 10:1 • Continuous flow through bypass. • Over-ranging is harmless. • No seal pots, no mercury, no purge fluids. • No condensation chambers. DESCRIPTION Brooks ByPass flowmeters measure linear fluid flow rates in conjunction with an orifice plate. This provides an inexpensive method of measuring flow rates in pipes of two inch or larger using relatively low-cost orifice plates. The bypass flowmeter consits of a mainline orifice, a set of orifice flanges, a flowmeter, a secondary orifice and bypass piping. A size 1/2” Metal Tube MT 3809 or Glass Tube GT 1000 is used to measure flow regardless of main line pipe size. See figure 1. The purpose of the mainline orifice plate is to create the pressure differential. The secondary orifice is sized such that the total pressure drop though the bypass piping equals the pressure differential across the mainline orifice. Because the same pressure drop exists across each line, the 1/2” flowmeter in the bypass line gives an exact indication of flowrate in the mainline. The Brooks ByPass flow meter with its secondary orifice is calibrated as a unit. Main line differential pressure and orifice practica data is available from ASME, DIN and manufacturers of primary elements. Because the flow through the bypass line is controlled by the secondary orifice, a change in orifice diameter changes the differential ranges. Brooks ByPass flowmeter units are made for “standard” differential ranges with interchangeable orifices. MATERIALS OF CONSTRUCTION Metering tube: GT 1000: Borisilicate glass MT 3809: 316 Stn. Stl. (dual certified), Monel 500, Hastelloy C, Hastelloy B, Titanium Gr. II Float: GT 1000: 316L Stn. Stl. MT 3809: 316L Stn. Stl., Monel 500, Hastelloy C, Hastelloy B, Titanium Gr. II Fittings: GT 1000: Brass or 316L Stn. Stl. MT 3809: 316 Stn. Stl. (dual certified) O-rings: GT 1000: Viton, Buna, Kalrez or EPDM MT 3809: Viton, Teflon Range orifice: 316 Stn. stl., Monel 500, Hasttelloy C, Hastelloy B, Titanium Gr. II Figure 1 ByPass construction with model MT 3809 3809 MT MAINLINE ORIFICE 1/2" PIPE METAL TUBE MODEL 3806 SECONDARY ORIFICE

Upload: others

Post on 26-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Brooks ByPass Flowmeters...Metal Tube MT 3809 or Glass Tube GT 1000 is used to measure flow regardless of main 1/2" PIPEline pipe size. See figure 1. The purpose of the mainline orifice

Technical SheetTS-023-VA-Bypass-eng-euMarch, 2008

1

Brooks® ByPass Flowmeters

DESIGN FEATURES•Lowcostandmaintenance.•Lineairtoflowandoutputsignals.•Rangeabilityupto10:1•Continuousflowthroughbypass.•Over-rangingisharmless.•Nosealpots,nomercury,nopurgefluids.•Nocondensationchambers.

DESCRIPTIONBrooksByPassflowmetersmeasurelinearfluidflowratesinconjunctionwithanorificeplate.Thisprovidesaninexpensivemethodofmeasuringflowratesinpipesoftwoinchorlargerusingrelativelylow-costorificeplates.Thebypassflowmeterconsitsofamainlineorifice,asetoforificeflanges,aflowmeter,asecondaryorificeandbypasspiping.Asize1/2”MetalTubeMT3809orGlassTubeGT1000isusedtomeasureflowregardlessofmainlinepipesize.Seefigure1.Thepurposeofthemainlineorificeplateistocreatethepressuredifferential.Thesecondaryorificeissizedsuchthatthetotalpressuredropthoughthebypasspipingequalsthepressuredifferentialacrossthemainlineorifice.Becausethesamepressuredropexistsacrosseachline,the1/2”flowmeterinthebypasslinegivesanexactindicationofflowrateinthemainline.

TheBrooksByPassflowmeterwithitssecondaryorificeiscalibratedasaunit.MainlinedifferentialpressureandorificepracticadataisavailablefromASME,DINandmanufacturersofprimaryelements.Becausetheflowthroughthebypasslineiscontrolledbythesecondaryorifice,achangeinorificediameterchangesthedifferentialranges.BrooksByPassflowmeterunitsaremadefor“standard”differentialrangeswithinterchangeableorifices.

MATERIALS OF CONSTRUCTIONMeteringtube: GT1000:Borisilicateglass MT3809:316Stn.Stl.(dual

certified),Monel500, HastelloyC,HastelloyB,Titanium

Gr.IIFloat: GT1000:316LStn.Stl. MT3809:316LStn.Stl.,Monel500,

HastelloyC, HastelloyB,TitaniumGr.IIFittings: GT1000:Brassor316LStn.Stl. MT3809:316Stn.Stl.(dualcertified)O-rings: GT1000:Viton,Buna,Kalrezor

EPDM MT3809:Viton,TeflonRangeorifice: 316Stn.stl.,Monel500,HasttelloyC,

HastelloyB,TitaniumGr.II

Figure 1 ByPass construction with model MT 3809

3809MT

MAINLINEORIFICE

1/2" PIPE

METAL TUBEMODEL 3806

SECONDARYORIFICE

Page 2: Brooks ByPass Flowmeters...Metal Tube MT 3809 or Glass Tube GT 1000 is used to measure flow regardless of main 1/2" PIPEline pipe size. See figure 1. The purpose of the mainline orifice

2

FLOW CAPACITIES

Flowcapacitiesdependontheallowabledifferentialpressureandthetypeofprimaryelementsused.Table1belowshowtheflowswhenusedasprimaryunita,flatplateconcentricorificewithpipeorflangepresuretaps,standardpipeandisbasedonadiameterratio(diameterratioisorificeboredividedbypipediameter)of0.70.Forotherdiameter-ratio’sseetable2.Themaximumadvisedratiois0.75andtheminimum0.35,preferableisaratiobetween0.50and0.65,i.e.max.flowbetweenapprox.50%and80%fromthetablebelow.

Table 1 Maximum Capacities For Air And Water

Notes:1) Waterflowsaregivenat20°Candaviscosityof1cP.2) Airflowsaregivenwithasupplypressureat6bargageandtemperature20°C.

Forotherfluidsorconditionspleasecontactfactory.

Table 2 Max. Capacity Correction For Other Diameter Ratio’s

Table 3 Rangeability For Various Brooks Flowmeters

DIFFERENTIAL PRESSURE kPa Nominal diameter 12,5 25 50 100 mainline Water Air Water Air Water Air Water Air pipe(mm) m3/h m3n/h m3/h m3n/h m3/h m3n/h m3/h m3n/h 50 13 1185 19 1730 26 2520 38 3470 80 29 2130 41 3000 59 4260 83 6000 100 51 3630 71 5210 102 7260 143 10420 125 78 5680 111 8070 156 11370 222 16110 150 110 8210 156 11530 220 16430 310 23060 200 199 14370 280 20540 390 28750 560 41080 250 310 22750 440 31600 620 45500 880 63200 300 440 31600 620 44280 890 63200 1260 88480 350 600 38870 860 52900 1210 75100 1720 105800 400 790 49240 1130 69260 1580 97800 2270 13900 500 1240 77160 1770 110080 2490 155300 3540 221200

d/D % max. capacity as stated in table 1

< 0.34 notrecommended 0.35 22 0.40 29 0.50 46 0.60 47 0.70 100 0.75 118

Differential Model GT1000 with Model GT1000 with Model MT3809 pressure float8-RV-3 float8-RV-14 float8-V-51(A) kPa inches WC range scale range range scale range range scale range 12,5 50 10:1 10%-100% 3.3:1 30%-100% n.a. 25 100 10:1 10%-100% 4:1 25%-100% n.a. 50 200 10:1 10%-100% 5:1 20%-100% 4:1 25%-100% 100 400 10:1 10%-100% 10:1 10%-100% 5:1 20%-100%

Page 3: Brooks ByPass Flowmeters...Metal Tube MT 3809 or Glass Tube GT 1000 is used to measure flow regardless of main 1/2" PIPEline pipe size. See figure 1. The purpose of the mainline orifice

3

ByPassflowmetertypeGT1000andMT3809

MoreinformationregardingtheBrooksByPassflowmeterscanbefoundintheirProductDataSheets(PDS)

GT 1000

MT 3809

ByPass Accuracy Class2.5acc.VDE/VDI3513

Repeatability ±0.5%ofrate

Scale length 250mm

Scale inscription Milimeter,percentofmax.flowordirectreadingunitson

detachablealuminiumplate

Maximum operating pressure 20bar

Maximum operating temperature -18°Cupto121°C

Connections AccordingtoPDS

Weight Approx.2,8kgformodelGT1000

Approx.3kgformodelGT1000withalarm

ByPass Accuracy Class2.5acc.VDE/VDI3513

Repeatability ±0.25%ofrate

Scale Standard:detachablealuminiumplate(singleor

dualscales)

Optional:choiceofdirectreadingunitsorpercentage

ofmaximumflow

Maximum operating pressure 152bar

Maximum operating temperature 324°C

Connections AccordingtoPDS

Weight Approx.1,3kgformodelMT3809

BYPASS OPTIONS

Mainlineorifice

MT 3809

SECONDARYORIFICE

MAINLINEORIFICE

1/2" PIPE

GLASS TUBEMODEL 1024

SECONDARYORIFICE

Bypass construction with flanged MT 3809 Bypass construction with flanged GT 1000

Page 4: Brooks ByPass Flowmeters...Metal Tube MT 3809 or Glass Tube GT 1000 is used to measure flow regardless of main 1/2" PIPEline pipe size. See figure 1. The purpose of the mainline orifice

4

E-Mail [email protected]

E-Mail [email protected] E-Mail [email protected]

DIMENSIONALDRAWINGS(inmm)

1/2" NPT-FIN / OUTLET CONN.

fitting withsecondaryorifice

hex 46mm

45

410

500 ±1

105

90

34 88

72

1/2" NPT-F

1/2" NPT-F

108

260 ± 3

35

158fitting withsecondary

orifice

MT 3809 for bypass construction GT 1024 for bypass construction

BROOKS LOCAL AND WORLDWIDE SUPPORT Brooksiscommittedtoassuringallofourcustomersreceivetheidealflowsolutionfortheirapplication,alongwithoutstandingserviceandsupporttobackitup.Weoperatefirstclassrepairfacilitieslocatedaroundtheworldtoproviderapidresponseandsupport.Eachlocationutilizesprimarystandardcalibrationequipmenttoensureaccuracyandreliabilityforrepairsandrecalibration.TheprimarystandardcalibrationequipmenttocalibrateourflowproductsiscertifiedbyourlocalWeightsandMeasuresAuthoritiesandtraceabletotherelevantInternationalStandards.Visit www.BrooksInstrument.com to locate the service location nearest to you.

START-UPSERVICEANDIN-SITUCALIBRATIONBrooksInstrumentcanprovidestart-upservicepriortooperationwhenrequired.Forsomeprocessapplications,whereISO-9001QualityCertificationisimportant,itismandatorytoverifyand/or(re)calibratetheproductsperiodically.Inmanycasesthisservicecanbeprovidedunderin-situconditions,andtheresultswillbetraceabletotherelevantinternationalqualitystandards.

CUSTOMER SEMINARS AND TRAININGBrooksInstrumentcanprovidecustomerseminarsanddedicatedtrainingtoengineers,endusersandmaintenancepersons.Pleasecontactyournearestsalesrepresentativeformoredetails.

HELP DESKIncaseyouneedtechnicalassistance: Americas 1-888-554-FLOW Europe +(31)-318-549-290WithinNetherlands 0318-549-290 Asia +011-81-3-5633-7100

DuetoBrooksInstrument'scommitmenttocontinuousimprovementofourproducts,allspecificationsaresubjecttochangewithoutnotice.