INDOOR UNITS - CEILING CASSETTE TYPE 4-WAY AIRFLOW
P L F Y - P N C M U - ETHE NEW 4-WAY CASSETTE NBMU OFFERS
72 DIFFERENT AIRFLOW PATTERNS, MAKING
IT IDEAL FOR APPLICATIONS WITH CEILINGS
UP TO 13-13/16 FT (4.2 m) IN HEIGHT.
A U T O M A T I C A I R S P E E D A D J U S T M E N TA u t o - f a n - s p e e d m o d e e n a b l e s s p e e d y a n dc o m f o r t a b l e h e a t i n g d u r i n g h e a t i n g s t a r t u p .The Auto-fan-speed mode is added to the usual foursteps Low, Mid1, Mid2, High. The Auto-fan-speedmode enables speedy and comfortable air conditioningbecause the air flow speeds up when starting, and airflow slows down when the air conditioning becomes
stable. (PLFY-P NBMU-E ONLY)
D R A F T - L E S S A I R D I S T R I B U T I O NThe newly employed horizontal blow mode* suppliesairflow horizontally, not bringing cooled/warmed airdirectly to occupants, thus preventing discomfortsensation due to excessive cooling or direct exposing ofoccupants to the air blow. (PLFY-P NBMU-E ONLY)W I D E A I R F L O WC o o l i n g s o f t l y w i t h W i d e A i r F l o w .Discharge air reaches wider area and the fan speed isdecreased by 20% thanks to the new wide shape air outlet.7 2 p a t t e r n s o f a i r f l o w t o a c c o m m o d a t e a n yr o o m l a y o u t a r e a v a i l a b l e .The number of outlets can be set to 4, 3, or 2. Flexible
airflow is available by fixing the up-down airflow direction
of the outlet with a wired remote controller (or manually).
I - S E E S E N S O R i - s e e s e n s o r c a n b e u s e d w i t h c e i l i n g c a s s e t t et y p e 4 - w a y a i r f l o w u n i t . ( O p t i o n P A C - S A 1 M E - EP L F Y - N B M U o n l y )New 4-way Cassette PLFY-NBMU controls the temperaturedifference at the top and bottom in a room by checking the flootemperature with i-see sensor.Comfortable air conditionincan be realized smoothly with sensible temperature
control. (Option PAC-SA1ME-E, PLFY-NBMU only)P r e v e n t s o v e r c o o l i n g / o v e r h e a t i n g , a n d i m p r o v e sc o m f o r t / e n e r g y e f f i c i e n c y .* When using a wireless remote controller, initial settings are required.
*On the commercial air conditioners (accordingto the survey by Mitsubishi Electric)
INDUSTRY FIRST
x
=
Compact body to match with 2 feet (600 mm)
x 2 feet (600 mm) ceiling design (NCMU)
P L F Y - P N B M U - E
* Default
* The ceiling may be smudged at a spot where
the supplied airflow is seriously distributed.
-
7/29/2019 brochure_PLFY_4way_R410A.pdf
2/3
78www.CityMult i .ca
CEILING CASSETTE TYPE 4-WAY AIRFLOW - INDOOR UNIT
SPECIFICATIONS
f1 Cooling / Heating capacity indicates the maximum value at operation under the following condition.Cooling: Indoor 80F (26.7C) D.B. / 67F (19.4C) W.B., Outdoor 95F (35C) D.B.Pipe length 25 ft. (7.6 m),
Level difference 0 ft. (0 m)
Heating: Indoor 70F (21.1C) D.B., Outdoor 47F (8.3C) D.B. / 43F (6.1C) W.B.Pipe length 25 ft. (7.6 m),Level difference 0 ft. (0 m)
f2 Airflow rate / Sound pressure level are in (low-middle2-middle1-high) or (low-middle-high).
f3 It is measured in anechoic room.
OPTIONAL PARTS
-
7/29/2019 brochure_PLFY_4way_R410A.pdf
3/3
V/M
V/M
V/M
V/M2-5/32(55)
1-3/8(35
)
1-3/8(35) 2-5/32(55)
Air intake hole
Airintakehole
Airoutlethole
Air outlet hole
11-27/32(301)
11-27/32(301)
14-27/32(377)
14-27/32(377)
25-19/32(650)
25-19/32(650)
9-1/16(230)
9-1/4(235)
8-3/16(208)
7-19/32(193)
25/32(2
0)
3-21/32(93)
2-19/32(66)
4-3/4(121)
7-15/16(202)11/16 (17)
+35
-5
(187.5) (160)
(160)
(7.5)
(24)
(840)
(160)
(20~45)
to1-25/3
2
(620)
(605
)
-3/16
+1-3/8
(90)
(150)
(160)
(7.5)
(20~45)
1-25/32
Branch duct hole
Fresh airintake hole
Ceilinghole
Suspensionboltpitch
Suspension bolt pitch
Ceiling hole
(5/16)
(5/16)
23-13/16
24-13/32
6-5/16
6-16/5
6-5/16
33-1/16(840)
5-29/32
3-17/32
33-1/16
7-3/8
25/32~1-25/32(20~45) 33-27/32 to 35-13/16(860~910) 25/32 to 1-25/32(20~45)
31-7/8(810)
25/32to
33-27/32to35-13/16(860~910)
25/32
15/16
6-5/16
14-27/3211-3/162-3/8
+5
0
(35)
(17
)+3/16
0
(190)
(156)
(50~70)
(140)
(170)
(377)(284)(60)
1-31/32
to
2-3/4
5-1/2
6-11/16
1-3/8
11/16
4-1/8(105)
6-9/64
7-15/32 AB
(950)
(500)
(36)
(83)
(36)
(83)
(500)
(950)
(597)
(597)
Air intake
grille
Air outlet hole
Airoutlethole
Airintakehole
Air intake hole
19-11/16
19
-11/16
23-1/2
M
M
M
M
3-17/64
1-27/64
37-3/8
3-17/64
1-27/64
37-3/8
23-1/2
(298)11-3/4
(258)10-3/16
PLFY-P36NBMU-E 11-1/16(281)
(241)9-1/2
Models BA
PLFY-P1215182430NBMU-E
79
INDOOR UNITS - CEILING CASSETTE TYPE 4-WAY AIRFLOWP L F Y - P N B M U - E P L F Y - P N C M U - EPLFY-P12/15/18/24/30/36NBMU-E PLFY-P08/12/15NCMU-EUpper viewLower view
Side view
Lower view
Side view