Product Overview Emission MonitoringAmbient MonitoringEnvironmental and Process Data Management Systems

Introduction Monitor selection

The DURAG GROUP develops and manufacturesproducts in the field of environmental measur-ing technology for measuring and monitoring

● dust concentration and opacity

● total mercury concentration

● flue gas volume flow

as well as evaluation systems for the calculationof emissions.

The products are used worldwide in power gen-eration plants and the process industry, such ase.g. fossil fuel power stations, waste incinerationplants, refineries, chemical processing plants,cement works, the lime industry, the steel indus-try, filter and dust extraction plants as well as formonitoring ambient air.

The DURAG Group is known for its high stan-dards of quality. DURAG has been ISO 9001 cer-tified for a number of years and has fully imple-mented the corresponding requirements. Theproducts are manufactured to national, Euro-pean and international standards.The following are taken into account:

● VDI 2066 / VDI 3950 – German dust meas-urement standard

● EN 14181 – European quality assurance stan-dard for automatic measuring equipment

● EN 13284 – European standard for determin-ing small dust concentrations

● EN 14884 – European standard for determin-ing total mercury concentration

● EN 12341 – European standard for determin-ing PM10 airborne dust

● ISO 10473 – International standard for betaabsorption method

● ASTM D-6216.98 – American dust measure-ment standard.

DIN EN 14181

DIN EN 14181 defines three so-called quality as-surance levels (QAL) and an annual functionaltest (AST) for automatic measuring systems:

● QAL 1: Requirement for use of automaticmeasuring equipment that has had its suit-ability tested (the test complies with DIN ENISO 14956)

● QAL 2: Installation of automatic measuringsystem (AMS), calibration of AMS using thestandard reference method (SRM), determina-tion of measuring uncertainty / variability ofAMS and check for observance of presetmeasuring uncertainties

● QAL 3: Continuous quality assurance by theoperator (drift and precision of the AMS, veri-fication on control card)

● AST: Annual surveillance test including SRMmeasurements to check the uncertainty ofthe AMS values.

DIN EN 14181 prescribes which characteristicsautomatic measuring equipment must possess,and how they must be calibrated and main-tained. In addition to the calibration function,measurement inaccuracy - which plays a deci-sive role in the validation of the measured val-ues obtained during continuous monitoring - isalso determined from the data of the calibra-tion. In addition, the requirements for the un-certainty of the measured values obtained withthe measuring equipment, which are defined inthe EU directives relating to large combustionplants, waste incineration plants and waste co-incineration plants, are checked using a methoddescribed in the standard.

QAL 1 – Testing the suitability of theequipment technology

QAL 1 specifies the suitability of a measuringdevice by calculating the total measuring uncer-tainty according to EN ISO 14956 before installa-tion, by taking account of all potential influ-ences.

Devices that have passed the TÜV suitability testand have been established as suitable measur-ing devices generally fulfil the standards ofQAL 1.

QAL 2 – Installation and calibrationcheck Selection of the measuring location and correctinstallation of the measuring device. Calibrationof the device using a standard reference me-thod, min.15 measuring points distributed over3 days, determination of the calibration curve orcurves in different operating conditions (fuels,load, etc.) and definition of the area of validity ofthe calibration curve.

Calculation of the total measuring uncertaintyof the measuring device.

QAL 3 – Continuous monitoring

Regular checks of the zero and reference pointdrifts during the plant operation by the operat-ing personnel should ensure reliable and cor-rect operation of the measuring device.

AST – Annual inspection

The calibration curve found in QAL 2 must bechecked / confirmed annually by means of 5parallel measurements.

In addition to the general data, such as de-sired measurand or measuring range, specialaccount must be taken of the plant conditionsat the measuring location when selecting asuitable measuring device, especially in thecase of dust concentration measurement.

OpacityA light beam sent through a mixture of gas andparticles is attenuated by absorption and diffu-sion. The more particles are found in the lightbeam, the stronger the opacity. The ratio of re-ceived light to initial light is a measurement ofthe transmission or the reciprocal opacity.

Extinction By converting the transmission to extinctionand after a gravimetric comparison measure-ment the display is in mg/m3. For dust concen-trations this result is displayed in mg/Nm3 bycalculation with the reference units T, P, RF.

Scattered light A light source emits light which is diffused byparticles in the gas and recorded by a detector.The scattered light principle is suitable for smalldust loads to under 1 mg/m3. The relationshipbetween measured value display and dust loadis determined by means of gravimetric compa-rison measurement.

Smoke spot number (soot) Scattered light measurement with very lowmeasuring range.Smoke spot number 1 corres-ponds to approx. 100 µg/m3. A comparisonmeasurement determines the relationship bet-ween display and smoke spot number.

TriboelectricityTriboelectricity results from friction betweenbodies or particles. If these charged particlesstrike a measuring probe, an electron transfertakes place. The value of the charge is a measu-rement for the dust mass flow rate. The relati-onship between measured value display anddust concentration can be determined by agravimetric comparison measurement.

Dew point Every gas mixture contains a defined quantityof humidity. The maximum possible saturationhumidity is dependent on the temperature: ifair is continuously cooled, with constant abso-lute air humidity the relative air humidity in-creases up to 100%. If the air is further cooled,the humidity condenses as water drops and af-fects the measuring result in optical and triboe-lectric measuring procedures.

TemperatureThe ambient temperature of the measuringhead may be maximum 50°C. In optical sys-tems, the purge air is also used as cooling airand separates the hot exhaust gas through thepurge air buffer. In transmission systems, thestandard assembly connection can be used upto an exhaust gas temperature of 200°C. Beyond this, the connection must be extended(approx. 1 mm / 1°C).

Pressure The standard purge air blower can be used upto a channel overpressure of 20 hPa. Beyondthis, special blowers are available. A flap valveshould be used in the event of overpressures. 2

Measurment Opacity Dust / Opacity Dust Soot Dust Dust Dust Total Mercury

Ambient Dust

Measuringprinciple Transmission Scattered Light Forward

Scattering Tribo Beta UVPhotometer Beta

DURAG GroupDevice D-R 216 D-R 216 OD D-R 290 D-R 300-40 D-R 300 D-R 800 D-RX 250 F-904-20 HM-1400TR F-701-20

TÜV ● ● ● ● ●** ● ● ● ●**

US EPA ●

GOST ● ● ● ● ● ●

MCERTS ● ● ● ● ●

Korean ●** ●** ●**

in-situ ● ● ● ● ● ● ●

extractive ● ● ●

Automatic zeroand control point ● ● ● ● ● ● ● ●

Automatic soilingcorrection ● ● ● ● N/A N/A N/A N/A

Fail safe shutters ● ● ● ● ● N/A N/A N/A N/A

Range switching ● ● opt. ● ● ●

Remote controlunit ● ●

Calibratable in mg/m3

wet mg/m3 mg/m3

wetsmoke spot

numbermg/m3

wetmg/m3

wet mg/m3 mg/m3

wet mg/m3

Measuringranges 0-25...100% 0-0.2...1.6 Ext 0-0.1...1.6 Ext

0-20...100% 0-1...100 mg/m3* 3 RZ 0-10...200

mg/m30-2...100

mg/m3 wet0-1...0-1000

mg/m30-45…500

µg/Nm30-0.1…10

mg/m3

Detection limit@ stack Ø 1 m 20 mg/m3 10 mg/m3 0.01 mg/m3 0.06 RZ 0.2 mg/m3 0.01 mg/m3 0.5 µg/Nm3 N/A

Detection limit@ stack Ø 5 m 8 mg/m3 2 mg/m3 0.01 mg/m3 0.06 RZ 0.2 mg/m3 0.01 mg/m3 0.5 µg/Nm3 N/A

Sample collection/Heavy metal

analysis● ●

* with measuring range switching 1000 mg/m3

** test pending

Devices for measuring emissions and immissions

Comparison of emission dust monitors according to application criteria

3

Optical opacity meter

The reliable system for monitoringdust emissions on small plants.

Features

● In-situ measurement directly in the flue gasflow

● Digital operation with microprocessor

● Adjustable limit value

● Contact switch outputs for pre-alarm and auto-power off

● Switchable measuring value integral 8 / 64 seconds.

Applications

● Compact device for smaller plants

● Heating stations, power stations

● Boiler plants in industry, barracks, hospitals,schools

● Dust extraction and filter plants

● Control of processes in the chemical industry.

Approvals

● Suitability-tested by the TÜV Cologne, test report 936/804004

● Itemized in the list of suitable measuring devices for continuous emission measuring.

Options

● D-R 216-41 measuring head with integratedauto-power off for boiler plants that are oper-ated without supervision as per TRD 604(BoB)

● Measuring head with spread measuringranges 0–50% and 0–25% opacity

● D-R 216 OD with measuring results in extinc-tion (calibratable for concentration display inmg/m3 dust)

● Weather protection covers for measuringhead, reflector and purge air unit

● Quick-closing shutters to protect measuringdevice in the event of failure of the purge airsupply.

model automaticshut-off

measuringrange display

D-R 216-40 without 0–100% opacity

D-R 216-41 with 0–100% opacity

D-R 216-45 without 0–50% opacity

D-R 216-46 with 0–50% opacity

D-R 216-47 without 0–25%* opacity

D-R 216-48 with 0–25%* opacity

D-R 216 OD without

0–0.2*0–0.40–0.80–1.6

extinction

*measuring path max. 3 m

Measuring principle

The device operates using the double-passmethod according to the auto-collimation prin -ciple. The light beam traverses the measuringdistance twice. The attenuation of the lightbeam by the dust content in the measuring sec-tion is measured and evaluated.

System components

● D-R 216-40 measuring head

● Reflectors for measuring distances 0.4 to6.25 m

● Mounting flanges

● Connection terminal box

● Zero point reflector

● Purge air unit.

Models

measurements opacity,optional extinction detection limit <3% of measuring range

measuring ranges0–100% OPoptional measuring ranges seetable above

reference pointdrift <0.6% of measuring range/month

measuringprinciple transmission zero point drift <0.2% of measuring range/month

flue gastemperature

above dew point up to 200°C,optional up to 500°C, dependingon application

supply voltage 115 / 230 VAC, 50 / 60 Hz, 30 VA

flue gas pressure -50 up to +20 hPa,optional higher

dimensions (H x W x D)

measuring head 160 x 150 x 314 mm

duct diameter 400–6250 mm weight 7 kg

ambienttemperature -20 up to +50°C purge air supply

protection IP65 purge air quantity approx. 80 m3/h

measuring output 0 / 4–20 mA / 400 Ohm supply voltage 115/230 VAC, 50/60 Hz, 0.37 /0.43 kW

digital outputs 2 relay outputs, permissable load 250 V / 100 VA

dimensions (h x w x d) 350 x 550 x 500 mm

digital inputs NA weight 12 kg

accuracy <2% of measuring range protection IP54

purge air unit

optical measuringunit

reflector

4

measurements opacity, extinction detection limit <2% of measuring range

switchablemeasuring ranges

opacity: 0–20% ... 0–100%extinction: 0–0.1 ... 0–1.6dust: 0–100 mg/m3 ... 0–4000 mg/m3 1)

reference pointdrift <0.4% of measuring range/month

measuringprinciple transmission zero point drift <0.4% of measuring range/month

flue gastemperature

above dew point up to 250°C,optional up to 1000°C, dependingon application

supply voltage 95–264 VAC, 47–63 Hz, 30 VA

flue gas pressure -50 up to +20 hPa,optional higher

dimensions (h x w x d)

measuring head 363 x 185 x 398 mm

duct diameter 1 up to 12 m, optional up to 18 m weight 7 kg

ambienttemperature

-20 up to +50°C,optional higher remarks

1) with reference to one meter ofpath length after gravimetriccalibration

protection IP65, Ex optional purge air supply

measuringoutputs

2 x 0 / 4–20 mA / 500 Ohm,manual or automatic measuringrange switching, optional ModbusRTU (RS 485)

purge air quantity approx. 80 m3/h

digital outputs 6 programmable relay outputs, permissable load 250 V / 100 VA supply voltage 115/230 VAC, 50/60 Hz,

0.37 / 0.43 kW

digital inputs 6 programmable potential freeinputs

dimensions(h x w x d)

weight

350 x 550 x 500 mm

12 kg

accuracy <1% of measuring range protection IP54

Optical opacity /dustmonitor

Standard system for plants withconcentrations >50 mg/m3.

Features

● In-situ measuring procedure, continuousmeasurement

● Semi-conductor source with long service life

● Super-wide band diode (SWBD), which pro-vides more stable measuring results in com-parison to devices with conventional LEDs

● Powerful microprocessor technology

● Measured value display on LC display in opacity, extinction or in mg/m3

● Automatic function tests with correction ofmeasured values in relation to soiling

● Optics and electronics in a hermeticallysealed unit - no smoke gas can enter device

● Easy adjustment without additional equip-ment

● Low-maintenance thanks to optimal purge airconduction.

Applications

Plants in which the dust concentration quantityneeds to be measured, e.g.:

● Furnace plants with semi-anthracite coal,brown coal, fuel oil and combined heating

● Converter plants, asphalt mixing plants

● Plants for cement manufacture.

Approvals

● Suitability-tested by the TÜV Cologne, test report 936/801017

● Itemized in the list of suitable measuring devices for continuous emission measuring.

● MCERTS

Measuring principle

The device operates using the double-passmethod according to the auto-collimation prin -ciple. The light beam traverses the measuringdistance twice. The attenuation of the lightbeam by the dust content in the measuring sec-tion is measured and evaluated.

System components

● Mounting flanges

● Measuring head

● Reflector

● Control and display unit

● Purge air unit.

Options

● Bus interface, e.g. Modbus or similar

● Automatic quick-closing shutters to protect the measuring head and the reflector in the event offailure of the purge air

● Weather protection covers, for outdoor installation

● Explosion proof design for EEx p, Zone 1 or Zone 2

● With an additional display unit at the measuring location, the control and display unit can be in-stalled in up to 1000 m distance away

● Temperature compensation through additional analog input

● Special model for measuring distances up to 18 m with 2 purge air units

● Filter set for sensitivity and linearity control.

optical measuringunit

reflector

purge air unit

control anddisplay unit

5

Measuring device forsmoke spot number

Extremely sensitive device formeasuring smoke spot number.

Measuring principle

The D-R 300 meter operates according to thescattered light method. The modulated lightfrom a Halogen lamp illuminates the dust parti-cles in the exhaust duct. The scattered light re-flected from these particles is measured and as-sessed.

Specifications

● Measuring range: smoke spot number 0-3.Limit value II can be set as delayed discon-nected contact

● Calibration: VDI 2066, page 8.

System components

● Measuring head

● Mounting flange

● Control and display unit

● 2 light traps

● Purge air unit.

Options

● Weather protection covers

● Quick-closing shutter to protect measuringdevice in the event of failure of the purge airsupply

● Halar flange coating.

Features

● In-situ measurement directly in the flue gasflow

● Automatic system tests and correction ofmeasured values

● Self-calibration in 4-h cycle

● Optics and electronics in a hermeticallysealed unit - no smoke gas can enter device

● Maintenance-friendly, thanks to optimalpurge air conduction in front of the heatedoptical end plates

● Direct access to all parameters via the opera-tor display.

Applications

● Smoke spot number measurement in fur-naces designed for light fuel oil.

Approvals

● Suitability-tested by the TÜV Cologne, test report 936/800002

● Itemized in the list of suitable measuring devices for continuous emission measuring

● MCERTS pending.

light trap

quick-closingshutter (optional)

measuring head

control anddisplay unit

purge air unit

measurements smoke spot number detection limit <1% measuring range

measuring ranges smoke spot number 1–3 (5) reference pointdrift <0.2% of measuring range/month

measuringprinciple back scattering zero point drift <0.2% of measuring range/month

flue gastemperature

obove dew point up to 320°C,optional up to 600°C, dependingon application

supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA

flue gas pressure -50 up to +20 hPa dimensions (h x w x d)

measuring head 565 x 310 x 200 mm

duct diameter 0.3 to 4 m weight 18 kg

ambienttemperature -20 up to +50°C remarks 1) after gravimetric calibration

protection IP65 purge air supply

measuringoutputs

2 x 0/4–20 mA/500 Ohm, optionalmeasuring range switching purge air quantity approx. 80 m3/h

digital outputs 3 relay outputs, permissable load 250 V / 100 VA supply voltage 115 / 230 VAC, 50 / 60 Hz,

0.37 / 0.43 kW

digital inputs 1 potential free inputdimensions

(h x w x d)weight

350 x 550 x 500 mm12 kg

accuracy <1% of measuring range protection IP546

Measuring device fordust concentration

Especially sensitive measuring device for the smallest concentra-tion of dust, in particular in wasteincineration plants.

Measuring principle

The D-R 300-40 meter operates according tothe scattered light method. The modulated lightfrom a Halogen lamp illuminates the dust parti-cles in the exhaust duct. The scattered light re-flected from these particles is measured and as-sessed.

Specifications

● Minimum measuring range 0-1 mg/m3 dustconcentration. Other measuring ranges up to300 mg/m3 can be set (optional automaticswitching of measuring ranges 1:3:9)

● Calibration: VDI 2066, page 7.

System components

● Measuring head

● Mounting flange

● Control and display unit

● 1 light trap

● Purge air unit.

Options

● Automatic measuring range selection for dustmeasurement in accordance with 17. BImSchV

● Weather protection covers

● Quick-closing shutter to protect measuringdevice in the event of failure of the purge airsupply

● High temperature option up to 500°C withadditional redundant purge air units

● Halar flange coating for waste incinerationplants.

Features

● In-situ measurement directly in the flue gasflow

● Automatic system tests and correction ofmeasured values

● Self-calibration in 4-h cycle

● Optics and electronics in a hermeticallysealed unit - no smoke gas can enter device

● Maintenance-friendly, thanks to optimalpurge air conduction in front of the heatedoptical end plates

● Direct access to all parameters via the opera-tor display

● Automatic measuring range selection in ac-cordance with 17. BImSchV. in relation 1:3:9.

Applications

● Fine dust measurements in processes

● Waste incineration

● Filter monitoring and emission-value measur-ing in waste incineration and power plants.

Approvals

● Suitability-tested by the TÜV Cologne, test report 936/801004

● Itemized in the list of suitable measuring devices for continuous emission measuring

● MCERTS pending.

light trap

quick-closingshutter (optional)

measuring head

control anddisplay unit

purge air unit

measurements dust concentration detection limit <1% measuring range

measuring ranges0–1 mg/m3 ... 0–30 mg/m3 1),

optional 0–300 mg/m3 with rangeswitching

reference pointdrift <0.2% of measuring range/month

measuringprinciple back scattering zero point drift <0.2% of measuring range/month

flue gastemperature

above dew point up to 320°C,optional up to 600°C, dependingon application

supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA

flue gas pressure -50 up to +20 hPa dimensions (h x w x d)

measuring head 565 x 310 x 200 mm

duct diameter 0.3 bis 4 m weight 18 kg

ambienttemperature -20 up to +50°C remarks 1) after gravimetric calibration

protection IP65 purge air supply

measuringoutputs

2 x 0/4–20 mA/500 Ohm, optionalmeasuring range switching purge air quantity approx. 80 m3/h

digital outputs 3 relay outputs, permissable load 250 V / 100 VA supply voltage 115 / 230 VAC, 50 / 60 Hz,

0.37 / 0.43 kW

digital inputs 1 potential free inputdimensions

(h x w x d)weight

350 x 550 x 500 mm12 kg

accuracy <1% of measuring range protection IP547

Dust monitor

Innovative measuring device withlaser technology to monitor smallto medium dust emission accordingto the new European regulations.

Features

● Integrated display: Measuring value,threshold value, parameter in probe

● In-situ measuring procedure with continuousmeasurement

● High sensitivity

● Easy installation on one side of the duct

● Can also be deployed in thick-walledstone/insulated channels

● Long lifetime, as there are no moving partsinside the duct

● Hermetically sealed electronic housingagainst exhaust gas

● Parameterisation and operation with key-board plus easily readable display directly ondevice or via bus interface

● Automatic function test with soiling correc-tion

● Two analog outputs with adjustable measur-ing ranges

● Automatic switching of measuring rangesaccording to 17. BImSchV.

Applications

● Power stations

● Cement plants, the metallurgy and wood in-dustries, chemical industry etc.

● Waste incineration plants

● Monitoring of dust filter plants.

Approvals

● Suitability test and MCERTS via Technical Inspection Agency (TÜV) pending.

System components

● Measuring lance

● Supply unit with integrated purge air supply

● Mounting flange 130 / 240 / 500 mm.

Options

● Weather protection cover

● Temperature compensation through addi-tional analog input.

Measuring principle

The D-R 800 device works according to the prin-ciple of forward scattering. The concentratedand modulated light of a laser diode penetratesthe measuring volume. The forward-scatteredlight largely reflected from dust particles ismeasured and assessed.

measuring lance

evaluation unit

supply unit withintegrated purge air

supply

RS 485 andanalogcurrentoutput

measurements dust concentration accuracy <2% of measuring range

measuring ranges 0–10 mg/m3 ... 0–200 mg/m3 1) detection limit <2% of measuring range

measuringprinciple forward scattering reference point

drift <2% of measuring range/month

flue gastemperature above dew point up to 220 °C zero point drift <2% of measuring range/month

flue gas pressure -50 up to +10 hPa supply voltage 85–264 VAC, 47–63 Hz, 50 VA

duct diameter 1–8 m dimensions (h x w x d)

measuring lance: 160 x 160 x 600 / 1000 mmsupply unit: 380 x 300 x 210 mm

probe length(from flange) 473 / 787 mm weight measuring lance: 7 kg

supply unit: 13 kg

ambienttemperature -20 up to +50°C purge air supply integrated into supply unit

protection IP65

measuringoutputs

2 x 0 / 4–20 mA / 500 Ohm, Modbus RTU (RS485)

digital outputs 4 relay outputs, programmable, permissable load 24 V / 25 VA

digital inputs 2 potential free inputs,programmable remarks 1) after gravimetric calibration

*pending

*

*

*

8

Combined probe sensor

Single rod measurement probe forsimultaneous measurement of - Dust concentration [mg/Nm³]- Volume flow [Nm³/h]- Temperature [°C]- Absolute pressure [hPa].

Features

● Only one probe / installation opening in theexhaust gas channel

● Compact design, no moving parts, no con-sumable parts

● Continuous conversion to normalised dustconcentration in mg/Nm3 and to normalisedvolume flow in Nm3/h

● LCD display in mg/Nm3, Nm3/h, °C and hPa,one analog output for each measurement value

● Parameterization at the control unit withoutthe need of a PC or other tools

● Remote connection of control and evaluationunit via two-wire bus interface up to 1000 m.

Applications

● For measurements in accordance with TI Air(Technical Instructions for Maintaining Air Purity), 13., 17. and 27. BImSchV

✖ Not suitable for use behind electro static pre-cipitators. Please consult us.

Approvals

● Suitability-tested by the TÜV Cologne, test report 936/800006/A

● Itemized in the list of suitable measuring devices for continuous emission measuring

● MCERTS pending.

measurements dust concentration, volume flow,absolute pressure, temperature detection limit <2% of measuring range

measuring ranges

0–10 ... 0–500 mg/Nm³0–9,999,999 Nm³/h 1)

0–200°C, optional 0–350°C900–1,300 hPa

reference pointdrift <1% of measuring range/month

measuringprinciple

dust: tribo electricvolume flow: differential pressure zero point drift <1% of measuring range/month

flue gastemperature

above dew point up to 200°C,optional up to 350°C, flue gas humidity <80%

supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA

flue gas pressure -200 up to 200 hPadimensions

(h x w x d)probe length

probes: 180 x 180 x (340 + probelength) mm250, 400, 700, 1000 mm

duct diameter 0.3–4 m weight probe 9.5 kgelectronics 22 kg

ambienttemperature -20 up to +50°C probe back

purging (option) purge air supply 3 bar

protection IP65 insulator purging(option)

continuous purge air supplyapprox. 2 m3/h

measuringoutputs

4x 0 / 4–20 mA / 500 Ohm, Modbus RTU (RS485)

digital outputs 7 relay outputs, permissable load 250 V / 100 VA

digital inputs 6 potential free inputsremarks

1) flue gas velocity >5 m/sconcentration after gravimetriccalibrationaccuracy <2% of measuring range

Measuring principle

● The tribo probe measures the electric chargeof the incident particles.

● The measurement of the volume flow isbased on the mechanical action principle. Theprobe has two separate chambers, betweenwhich a differential pressure builds up underflow.

● The absolute pressure in the flue gas ismeasured by a pressure transmitter in onechamber of the probe.

● The temperature is measured directly in thecentre of the flue gas flow in a separate cham-ber within the probe with a temperature sen-sor.

● Dust concentration is calculated from the triboelectric measuring signal and the vol-ume flow. To this purpose in calibration, youreceive the necessary parameters for the rele-vant speed ranges, which form the basis forcalculating dust concentration. The raw datathat are also measured for gas temperatureand absolute pressure are used to calculatethe standard dust concentration and the stan-dard volume flow (wet).

probe transmitter differentialpressure

transducer

control andevaluation unit

System components

Options

● Weather protection cover

● Switch-over cock for back purging / zeropoint control

● Automatic cyclic probe back purging for highdust concentrations

● Hastelloy probes for corrossive gases

● Purge air connection at flange.

max. 1000 m

9

Filter monitor

Triboelectric filter monitor for efficiency monitoring after filterplants and for continuous dustmeasuring in dry emissions.

Features

● Compact and rugged design

● Good price/performance ratio

● Ideal for monitoring bag filters

● Minimal maintenance required

● Early detection of filter malfunctions

● Savings in cost, as no preventative filter ex-change is necessary.

Applications

● Power stations

● Bag filter plants of all types

● Dust extraction plants in the production in-dustry

● Waste incineration plants

● Crematoriums

✖ Not suitable for use directly behind electro -static precipitators.

Approvals

● Suitability-tested by the TÜV Hamburg, test report 98CU026

● Itemized in the list of suitable measuring devices for continuous emission measuring.

Measuring principle

The filter monitor uses the triboelectric effect todetermine dust loads in flowing gases. The elec-trical charge which the dust particles experi-ence due to friction is picked up by a probe pro-truding into the dust channel and converted in-to a measuring signal by electronics. Themeasuring signal is proportional to the dustconcentration and is calibratable at a constantgas speed.

System versions

D-FW 231 measuring probe

● With complete electronics in the probe

● Probe rod length 400 mm

● Fitted via 1“(G1) thread

D-FW 230 filter monitor

● D-FW 231 measuring probe Probe rod length400 mm

● D-FW 230-B control unit with digital display115/230V 50/60 Hz.

Options

● Measuring gas temperature up to 500°C

● Ex version D-FW 240/Ex

● Weather protection cover

● Various mounting options (flange, connectionpiece)

● Probe rod lengths 80, 250, 700 mm

probe control unit

measurements dust mass flow detection limit <2% of measuring range/month

measuring ranges 0–100%(flue gas velocity >5 m/s)

reference pointdrift <0.3% of measuring range/month

measuringprinciple tribo electric zero point drift <0.3% of measuring range/month

flue gastemperature

above dew point up to 200°C,optional up to 500°C, flue gas humidity <80%

supply voltage 24 VDC, 5 VA115 / 230 VAC, 50 / 60 Hz, 10 VA*

flue gas pressure -500 up to +500 hPadimensions

(h x w x d)probe length

probe: 180 x 80 x (270 + probelength) mm80, 250, 400, 700 mm

duct diameter 0.3–4 m weight probe: max. 4.5 kgcontrol unit: 3 kg

ambienttemperature -20 up to +50 °C

protection IP65

measuringoutputs 0 / 4–20 mA / 500 Ohm

digital outputs* 1 relay output, permissable load 250 V / 100 VA

digital inputs* 2 potential free inputs

accuracy <2% of measuring range remarks *D-FW 230 only10

Measuring principle

The filter monitor uses the triboelectric effect todetermine dust loads in flowing gases.

System components

● Filter monitor D-FW 231

● Three measuring probes, lengths 80 mm,250 mm and 400 mm

● Line recorder

● Accessories

● System container.

System versions

D-FW 235-21 measuring system

● with single-channel strip chart recorder, in-cluding an interface to a PC. The line recordercalculates and records min/max values andintegrated measured values and prints themout on paper

D-FW 235-34 measuring system

● with four-channel paperless recorder, colourscreen and data stor age options plus threeadditional current inputs for inclusion of oth-er measured values.

measurements dust mass flow detection limit <2% of measuring range/month

measuring ranges 0–100%(flue gas velocity >5 m/s) supply voltage 115 / 230 VAC, 50 / 60 Hz, 10 VA

measuringprinciple tribo electric dimensions probe

180 x 80 x (270 + probe length) mm80, 250, 400, 700 mm

flue gastemperature

above dew point up to 200°C,optional up to 500°C, flue gas humidity <80%

dimensionssystem container

(w x d x h)520 x 205 x 460 mm

flue gas pressure -500 up to +500 hPa weight probe: max. 4.5 kg

duct diameter 0.3–4 m weight systemcontainer 13.5 kg

ambienttemperature

probe: -20 up to +50°Csystem container: 0...50°C cable length connection cable probe / system

container: 5 m, mains cable: 2 m

protection IP54 lid closed

measuringoutputs 0 / 4–20 mA / 500 Ohm

accuracy <2% of measuring range

Mobile filter monitor

Mobile measuring system with triboelectric probe and integrateddata recording for efficiency moni-toring after filter plants.

Features

● Compact and rugged design

● Ideal for bag filter plant monitoring

● Early detection of filter malfunction

● Portable design for random inspection of en-tire filter plants

● Saves costs since preventive filter change isunnecessary.

Applications

● Power stations

● Bag filter plants of all types

● Dust extraction plants in the production in-dustry

● Waste incineration plants

● Crematoriums

● Sampling inspection in filter plants

● Acceptance reporting of filter plants

● Trouble shooting limit value exceedance in fil-ter plants

✖ Not suitable for use in plants with electro -static filters.

Approvals

● Suitability-tested by the TÜV Hamburg, test report 98CU026

● Itemized in the list of suitable measuring devices for continuous emission measuring.

Options

● Measuring gas temperature up to 500°C

● Other probe lengths

● Adaptor for 3“-flanges, DIN-flange and taperflange

● Longer connection cable between probe andsystem container.

probe system container with strip chart recorder and operation panel

11

sample probe, nozzlepressurized air

dilution gas control valve

Extractive beta gaugeparticulate monitor

Dust monitor especially for wet flues- emission temperature under dewpoint - and for the monitoring ofblast furnace gas.

Features

● Automatic zero correction

● Pre-calibrated, unaffected by particle size,colour or moisture

● Sample gas flow regulated at 1 - 3 m3/h

● Isokinetic sampling

● Optional dilution sample probe for high con-centrations or after wet scrubbers

● Heavy metal analysis possible

● Special model with measuring chamber purg-ing and CO-TLV monitoring during dust moni-toring of blast furnace gas.

Applications

● Coal and oil-fired power stations

● Waste incineration plants (municipal waste,industrial waste and hazardous waste)

● Sewage sludge incineration plants

● Emission dust measurement after wet scrub-bers or in very wet exhaust gases

● Heavy metal analysis

● Measurement of very low dust concentrationsin emissions

● Emission dust measurement in inaccessibleflues with small diameter

● Dust concentration measurements in processapplications.

Approvals

● Suitability-tested by the TÜV Essen, test report 3.5.2/209/88-338529

● Itemized in the list of suitable measuring devices for continuous emission measuring

● Type approval: HH 1/98

● PTB test certificate no. 6.22-R202.

Options

● Special design F-904-20/BFG for measurement of the dust concentration in toxic and explosiveblast-furnace gas with shut-off valves for the sample gas during filter transport and with purge gas(usually nitrogen) for line back purging. A CO detector is also provided, which closes all gauge con-nections to the process gas if the CO threshold limit value is exceeded and gives an alarm

● Filter tape printer and protective sheet for specimens in heavy metal analyses.

Measuring principle

Determination of the dust concentration bymeasuring the absorption of beta rays emittedby a radioactive emitter by particles collectedfrom an exhaust gas flow.

System components

● Heated sample probe (material 1.4571 or tita-nium), with or without dilution

● Heated sample line in 1.4571

● Filter tape in gas-tight filter holder

● C-14 emitter and detector (Geiger-Müllercounter)

● Sample gas cooler

● PLC control, also for calculating the concen-tration from the dust content.

counter tube

tape-filter printer(option)

C-14 source

filter adapter

supply reel

take-up reelfilter advancesteppingmotor

sample cooler withautomatic drain

4–20mASTATI

PLC

total flowvacuum pump

with bypasscontroller

total flowVenturinozzle

dilutiongas Venturi

nozzle

cover foil(Option)

measurements dust concentration detection limit <0.3 mg/Nm3

measuring ranges 0–1 ... 0–1000 mg/Nm3 reference pointdrift <1% of measuring range/month

measuringprinciple beta ray absorption zero point drift automatic zero point correction

flue gastemperature

0–250°C, optional up to 500°C supply voltage 115 / 230 VAC 50 / 60 Hz, 5 kVA

flue gas pressure -100 up to +100 hPa dimensions (h x w x d) 1600 x 800 x 800 mm

duct diameter >0.5 m weight 300 kg

ambienttemperature 0 up to +50°C, cooler optional purge air supply pressurized air 6–8 bar

protection IP43 (with filter blower), upgradable to IP54

measuringoutputs 2 x 0 / 4–20 mA / 450 Ohm

digital outputs 11 relay outputs, permissable load 24 V / 25 VA

digital inputs 2 potential free inputs

accuracy <5% of measuring range option dust monitoring of blast furnacegas12

Beta gauge particulatemonitor

A measuring device for the continu-ous monitoring of the smallest concentration of particles in the ambient air (fine dust).

Options

Further sample inlets:

● PM-2.5 (accordant EN 12341)

● PM-10 (according to EN 12341)

● Total dust (according to VDI 2463)

Measuring principle

The measuring principle of the F-701-20 am-bient dust monitor is based on the absorptionof the beta rays (electrons) emitted by a radio-active emitter through particles collected froman ambient air flow. In the F-701-20 the pulse rate of the unloaded filter tape is measured be-fore each collecting cycle, then dust is collectedon this precise filter spot over a pre-defined period, and finally the pulse rate of the loadedfilter tape is measured. The difference betweenthe two pulse rates is evaluated in the deviceand displayed as dust concentration in µg/m3.

measurements dust concentration accuracy <2% of measuring range

measuring ranges 0–0.1 ... 0–10 mg/m3 detection limit <0.001 mg/m3

measuringprinciple beta-ray absorption reference point

drift <1% of measuring range/month

ambienttemperature 0 up to +50°C zero point drift automatic zero point correction

protection IP20 supply voltage 230 VAC / 50 Hz, 110 V / 60 Hz, 400 VA

measuringoutputs 2 x 0 / 4–20 mA / 500 Ohm dimensions

(h x w x d)320 x 450 x 500 mm, 19“-rack mount / desk unit

digital outputs 8 relay outputs, permissable load 24 V, 12 VA weight 26 kg

digital inputs 3 potential free inputs probe tube length standard 2 m0.5–5 m possible

Features

● C-14 method, no measurable decrease in activity

● Lowest radioactivity of all beta gauges, usablewithout licence, or disclosure

● Automatic zero correction

● Pre-calibrated, no site-specific calibration required

● Mass-flow controlled sample flow 1m3/h

● Extraction of a constant sample flow, irrespec-tive of the ambient temperature

● Repeated collection on the same spot, col-lected particles available for heavy metalanalysis

● RS-232 interface and analog output, statussignals

Applications

● Immissions measuring systems for monitor-ing fine dust

● Mobile immissions-measuring

● Dust measurement in health and safety appli-cations

● Interior dust measurements

● Measurement and collection of dust particlesfor heavy metal analysis

● Long-term background studies in ambientdust concentration

● Dust measurement and collection at problemsites and repositories

● Dust measurement for secondary emission ofrepositories (e.g. coal).

● Dust measurement in supply air and exhaustducts.

Approvals

● Type-tested by TÜV.

sampling probe, sample inlet

counting tube

C-14 sourcefilter housing

supply reel

bypasscontrol valve

vacuumpumpsamplevolume flow

flow meter

secondary tubeheating (option)

protective foil(option)

filter tape printer(option)

stepper motorfor filter feed

evaluation, control

interface

Options

measuredvalue

printer

stripchart

recorder

PC: read/write datafrom/to instrument

13

Total mercury analyser

Measuring device for fully-automaticand continuous mercury analysis insmoke gas (without wet chemistry).

Features

● Maintenance-free (6 months) dry reactor

● High operational safety

● Easy maintenance

● Low cross sensitivities

● Easily legible LC display.

Applications

● Waste incinerations (municipal waste, indus-trial waste, hospital waste)

● Sewage sludge incineration

● Hazardous waste incineration

● Steel plants with scrap metal preparation

● Contaminated soil burning plants

● Crematoriums

● Mercury mines and refineries

● Fluorescent light bulb recycling plants.

Approvals

● Suitability-tested by the TÜV Hamburg, test report 00 CU 014

● Itemized in the list of suitable measuring devices for continuous emission measuring

● MCERTS pending.

Measuring principle

In the HM 1400 TR total mercury analyser thesample gas is converted into mercury vapour bya combination of thermal and dry chemicaltreatment. This is then continuously measuredin a photometer. The probe gas flow is meas-ured after a gas cooler at 2°C. The concentrationis calculated and displayed as „dry flue gas“.

Options

● Larger measuring range with dilution device

● Top-mounted cooling device

● Automatic probe back purging device, dilu-tion device for gas sample

● Integrated system to generate calibration gas.

System components

● sampling probe

● sampling line

● measuring device.

thermocatalyticreactor

zero gasfilter

heated sample probe

calibrationreactor

option

Hg-photometer

gas/liquidseparator

condensatecalibrationstandard

liquidwatchdog

pump

measurements total mercury detection limit <1 µg/Nm³

measuring ranges 0–45 ... 0–500 µg/Nm³ reference pointdrift <2% of measuring range/month

measuringprinciple UV-absorption zero point drift automatic zero correction

flue gastemperature 0–250 °C supply voltage

230 VAC, 50 Hz, 1200 VA, sample probe: 650 VA, sample line: 100 VA/m

flue gas pressure -50 up to +50 hPa dimensions (h x w x d)

cabinet1600 x 800 x 500 mm

duct diameter >0.5 m weight 220 kg

ambienttemperature +5 bis +30°C purge air supply pressurized air 3–6 bar

protection IP40 (IP55)

measuringoutputs 2 x 0 / 4–20 mA/500 Ohm

digital outputs 4 relay outputs, permissable load 250 V, 100 VA

digital inputs 1 potential free outputs

accuracy <1% of measuring range14

Volume flowmeasuring system

Measuring system to measure flowrate in dry emissions with a probeusing the differential pressure prin-ciple.

Features

● Measurement of emission speed

● Calculation of volume flow at standard condi-tions with the evaluation unit D-FL 100-10(optional)

● Adjustable parameters

● Automatic back purging device (optional)

● Versions with or without counter-support andfor point measurement.

Applications

● Volume flow measurement at high tempera-tures

● Plants with large or small flue cross-sections

● Volume flow measurement at high pressure.

Approvals

● Suitability-tested by the TÜV Hamburg,test report 128CU11650

● Itemized in the list of suitable measuring devices for continuous emission measuring.

● MCERTS pending.

differentialpressure

transducer

flow 4 ... 20 mA

4 ... 20 mA

absolutepressuretransducer(optional)

cross-overcock

flow probe

flow direction

temperaturetransducer(optional)

4 ... 20 mA

micropro -cessor

evaluation unit

Probes

● Probe 1: 0.4–2 m● Probe 2: up to 4 m● Probe 3: up to 8 m.

System components● Mounting flange ● Flow probe ● Counter-support ● Differential pressure transducer ● Cross-over cock ● Probe adapter.

Options● Microprocessor evaluation unit D-FL100-10 ● Absolute pressure transducer ● Temperature transducer ● Weather protection covers● Automatically controlled back purging device ● Special designs in other materials for applica-

tions with particularly aggressive exhaustgases or high gas temperatures

● dP-transducer in Ex-version.

Measuring principleThe D-FL 100 measuring system operates accor-ding to the differential pressure principle. Theprobe has two separate chambers, betweenwhich the flow builds up a differential pressure.Taking account of the other flow parameterssuch as, e.g. absolute pressure and temperature,the volume flow can be converted from opera-ting to standard conditions with the help of theD-FL 100-10 microprocessor evaluation unit.

Models

● D-FL 100 probe assembly with assembly of measuring transducer onthe probe (not for probe 3)

● D-FL 100 hose assembly with the measuring transducer connectionvia hose line.

measurements flue gas velocity, volume flow 1) accuracy <2% of measuring range

measuring ranges 0–3000000 m3/h / 3–40 m/s detection limit <3 m/s

measuringprinciple differential pressure reference point

drift <0.5% of measuring range/month

flue gastemperature

above dew point up to 400 °C,optional up to 800 °C zero point drift <0.5% of measuring range

flue gas pressure -700 up to 1000 hPa, optionalhigher supply voltage 14–45 VDC

115 / 230 VAC, 50 / 60 Hz, 50 VA 2)

duct diameter 0.4–8 m dimensions (h x w x d)

probe: 380 x 160 x (300 + probelength) mm

ambienttemperature -20 up to +50 °C weight 32 kg + 6,8 kg/m probe length

protection IP65, Ex optional purge air supply 6–8 bar for back purging ifneccessary

measuringoutputs 0 / 4–20 mA / 500 Ohm 2)

remarks1) optional pressure and

temperature correction2) only with evaluation unitdigital outputs 3 relay outputs,

permissable load250 V, 100 VA 2) 15

Volume flowmeasuring system

Measuring system for ultra-sonicmeasuring of velocity and volumeflow, especially for wet and aggres-sive smoke emissions (waste incin-eration).

Features

● In-situ measuring method

● Measurement possible below dew point andfor high dust concentrations

● Continuous measurement of normal volumeflow and gas velocity

● Automatic zero point and reference pointcontrol

● Direct connection for temperature and pres-sure correction

● Parameter input via keyboard or PC

● Continuous temperature measuring.

Applications

● Volume flow measuring at low speeds

● Plants with damp and/or aggressive exhaustgas, e.g. in waste incineration plants.

● Volume flow measurement at high dust con-tent.

Approvals

● Suitability-tested by the TÜV Hamburg, test report 99CU019

● Itemized in the list of suitable measuring devices for continuous emission measuring

● MCERTS pending.

measuring headtemperature

transducer(optional)

purge air

purge air

absolutepressure

transducer(optional)

evaluation unit

duct

Measuring principle

The D-FL 200measuringsystemworks ac-cording totheacoustictransit timedifferential method. Ultrasonic trans-ducers mutually send and receive shortpulses with and against the gas flow di-rectionwhich affects their transit time. Thevolume flow is calculated from the differ-ence of transit times.

System components

● 2 mounting flanges (Mat. 1.4571)

● 2 measuring heads

● Evaluation unit D-FL 200-10 with housing

● Purge air unit for cleaning and cooling thesensors.

measurements flue gas velocity, volume flow 1),temperature detection limit <0.3% of measuring range

measuring ranges 0–3000000 m3/h / 0–40 m/s0–400°C

reference pointdrift <0.3% of measuring range/month

measuringprinciple acoustic propagation delay zero point drift <0.2% of measuring range/month

flue gastemperature 0–200 °C, optional higher supply voltage 115 / 230 VAC, 50 / 60 Hz, 50 VA

flue gas pressure -50 up to +20 hPa, optional higher dimensions (h x w x d)

standard measuring head: 190 Ø x 570 mm

duct diameter 0.7–10 m, temperature dependent weight 17 kg

ambienttemperature -20 up to +50 °C remarks

1) optional pressure andtemperature correction

protection IP65 purge air supply

measuringoutputs

2 x 0 / 4–20 mA / 500 Ohm, optional Modbus RTU (RS 485) purge air quantity approx. 80 m3/h

digital outputs 3 relay outputs, permissable load 250 V, 100 VA supply voltage 115 / 230 V, 50 / 60 Hz,

0.37 / 0.43 kW

digital inputs none dimensions weight

350 x 550 x 500 mm12 kg

accuracy <2% protection IP54

Options

● Modbus interface

● Temperatue transducer

● Absolute pressure transducer

● Weather protection covers

● Purge air sensor with poten-tial free error contact.

16

Environmental andprocess data management system

Modular system for continuous ac-quisition, long-term storage, calcula-tion and visualisation of environ-mental and process data.

Features

● Instrument for monitoring legally prescribedlimit values and recording their observance

● Emission monitoring and remote data trans-mission to the authorities

● Adjustable to any plant size through to com-plete assessment of complex industrial sites

● Continuous monitoring of 1 to 320 compo-nents per system workstation

● Interconnection of any number of compo-nents via data networks.

Approvals

● Suitability-tested by the TÜV Munich, test report 24108990

● Itemized in the list of suitable systems for theevaluation of continuous emission measur-ing.

Measured data recording

● Analog/digital inputs - as sub-rack with intermediate data storage - or as local modules

● Data transmission via bus systems, Modbus,Profibus,TCP/IP or other interfaces.

Data sources

● Emission data

● Immission data

● Meteorological data

● Water data

● Process data.

Data export

● Data interface to MS-Excel with option of fur-ther measured data evaluation, e.g. for fulfill-ment of environmental protection officer’s re-porting duties

● Measured data can be transfered to authori-ties via standard remote communication orvia internet

● Merging of measured data e.g. for greenhoseemission trading

● Remote service interface for fast and cost ef-fective service.

Data security

● Paperless data storage to replace recordersand printers is possible through integrateddata security, which is guaranteed on severallevels in the system

● Intermediate storage of the raw input valuesat minute intervals in data communicationunit D-MS 500 KE

● Double data storage on two separate harddisks in a RAID1 set

● Storage of analog raw values at second inter-vals

● Data backup on external redundant drive.

Internet/Intranet connection

● Data transfer to an Internet server with HTMLstandard masks via standard software (MS-Internet-Explorer)

● Password-protected control of daily emissionvalues including classification records.

Visualisation

● Measured data recording according to officialregulations

● Classification tables, daily, monthly and annu-al records

● Representation of current, prognostic and his-toric measured data in bar/chart form

● Pollutant compensation, characteristics curveand correlation

● Automatic alarm and information system.

17

Features

● DURAG D-EMS 2000 Environment andProcess Data Management Systems Module

● No separate web server necessary

● Visualisation of all data with standard browserMS Internet Explorer

● High security levels through password protec-tion and ring memory

● Representation of protocols and tables in universal PDF format

● Authority and operator have the same protocols and tables

● Graphical/numerical representation of transmitted values

● Download for representation in MS Excel

● No operating and update costs for authorities.

Data transfer

● Data transfer occurs on a (half-) hourly basisso that authorities always have all values athand, including the last integral

● With the transfer of average values, theagreed events (e.g. excess ELV, breakdownARE) that occurred within the past 30 or 60minutes are also provided

● Comment option by the operator

● The protocols are generated on theoperator´s PC and transferred to the relevantInternet server in PDF format. This rendersparallel archiving on an official serverunnecessary

● All data are stored on an Internet server in dynamic ring memories over 24 months

● Visualisation and possible downloads arepassword-protected and free of charge forthe authorities.

Software module foremission remote datatransmission to theInternet

The state-of-the art online information platform for the relevant authorities.

Overview site athttp://www.durag.info

● Demonstration unit under „DURAG Demo“

● The installed password-protected operatorunits can be opened via appropriate logos

● Country-specific official sites can be creat-ed upon the authority´s request.

The class frequency distribution is transmitted daily aftermidnight in PDF format as copy of the protocol generated bythe operator.

Line diagrams can be called up for clearly visible representationof average values.

Protocols are generated automatically at the end of the day and stored on the server as PDF files.

Official (validated) half-hourly average values are listed in the daily protocol.

All daily average values are listed in the monthly protocol.

Data transfer to Internet:

after daily change: Official classification protocol, daily protocol, monthly protocols

(half-) hourly: Current (half-) hourly average values, events of the last 30 or 60 minutes

Immediate transfer: Events, comments, news

18

Features

● DURAG D-EMS 2000 Environment andProcess Data Management System Module,also available as a separate programme

● Drift and precision calculation for zero andAMS reference point

● Automatic import of current zero andreference point values of the AMS

● Manual input option for calculation of AMSrequired values without automatic zero andreference point control

● Automatic archiving and long-term storage ofall generated CUSUM control cards fordocumentation within the frame of functionaltesting

● Graphical/numerical representation of allinput data and calculations

● Complete AMS document managementaccording to EN 14181 point 9 Appendix D

- Identification of AMS (type, manufacturer,installation site, etc.)

- Connection entries (activities, events,personnel, etc.)

- Test reports

- Calibration reports

- Reports on interventions

- Drawings (gas operational plans,connections, etc.)

- Pictures (overall configuration,particularities, etc.)

- Procedural instructions

- Operating instructions

- Staff qualifications.

Software for completedocumentation ofAMS, drift andprecision (QAL3)according to EN 14181

Identification of the AMS

Creation of CUSUM control card

CUSUM control card with detailedinformation about precision anddrift as well as the decision forreadjustment

Spreadsheet and line diagramwith historical data

19

©DURAG GROUP 05/2006 · Änderungen vorbehalten · Subject to change without notice · Sous réserve de modification

DURAG GmbHKollaustrasse 105 · 22453 HamburgTel. +49 40 554 218-0 · Fax +49 40 584 154E-Mail: [email protected]

DVN - DURAG Vertrieb NordKollaustraße 105 · D-22453 HamburgTel. +49 40 554 218-0 · Fax +49 40 584 154E-Mail: [email protected]

DVO - DURAG Vertrieb OstMeißner Ring 4 ·D- 09599 FreibergTel: +49 3731 3004-0 · Fax: +49 3731 3004-22E-Mail: [email protected]

DVS - DURAG Vertrieb SüdWeidenweg 16 · D-73087 Boll Tel: +49 7164 91225-0 · Fax: +49 7164 91225-50 E-Mail: [email protected]

DVW- DURAG Vertrieb WestAn der Pönt 53a · D-40885 RatingenTel: +49 2102 7400-0 · Fax: +49 2102 7400 28E-Mail: [email protected]

DURAG France S.a.r.l.Parc GIP Paris Charles de Gaulle49, rue Léonard de Vinci95190 GOUSSAINVILLE, FranceTel.: +33 1 301 811 80 · Fax: +33 1 393 383 60E-Mail: [email protected]

DURAG UK Office12 Ashendene GroveHanford, Stoke on TrentStaffordshire, ST4 8NLGreat Britain Tel.: +44 1782 657 666 · Fax: +44 1782 646 020E-Mail: [email protected]

DURAG, Inc.Southridge Business Center, 1355 Mendota Heights Rd. #200Mendota Heights · Minnesota 55120, USATel. +1 651 451-1710 · Fax +1 651 457-7684E-Mail: [email protected]

Durag India Instrumentation Private Limited102, Sophia's Choice · St. Mark's RoadBangalore - 560 001 · IndiaTel. +91 80 4112 0223 · Fax +91 80 4112 0224E-Mail: [email protected]

DURAG ChinaRoom 708 · TSENG CHOW Commercial Mansion 1590 Yan An West RoadShanghai 200052 · P. R. ChinaTel.: +86 21 62808277 · Fax +86 21 62809236E-Mail: [email protected]

www.durag.de

Hegwein GmbHAm Boschwerk 7 · 70469 StuttgartTel. +49 711 135 788-0 · Fax +49 711 135 788-5E-Mail: [email protected]

VEREWA Umwelt- und ProzessmesstechnikGmbHKollaustrasse 105 · 22453 Hamburg,Tel. +49 40 554 218-0 · Fax +49 40 584 154E-Mail: [email protected]

ORFEUS Combustion Engineering GmbHKollaustrasse 105 · 22453 HamburgTel. +49 40 554 218-0 · Fax +49 40 584 154E-Mail: [email protected]