bro dvta10020 uk
TRANSCRIPT
-
8/10/2019 Bro Dvta10020 Uk
1/4
smart solutions for combustion and environment
Video and thermographyanalyzing systemfor cement plants
The information system for: Optimization of main burner operation Secondary fuel control Free lime prediction Stabilization of product quality Detection of "snowman" and "red river" Optimization of maintenance and repair cycles
-
8/10/2019 Bro Dvta10020 Uk
2/4
-
8/10/2019 Bro Dvta10020 Uk
3/4
Holcim Siggenthal, Switzerland W&P Wietersdorf, Austria Buzzi Unicem Vernasca, Italy
Video system PAL, picture elements:752(H) x 582(V), fixed focus
Thermographyfrom total radiation
Temperature range1000C 1800C
Optical alignment Sensor 0: axially-parallel tosensor axis,Sensor45: angled 45 tosensor axis
Optical field of view
Sensor 0:horizontal 72, vertical 54,diagonal 90;Sensor 45:horizontal 48, vertical 36,diagonal 60
Data interfaces onthe system PC
RS232, RS422, RS485:ASCII, MODBUS, Siemens RK512;Ethernet: TCP/IP: FTP, MODBUS
Auxiliary energy 230 V / 50 Hz, 500 VA
Gas temperature incombustionchamber
Water-cooled sensor
-
8/10/2019 Bro Dvta10020 Uk
4/4
DURAG Inc.
DURAG UK
DURAG France DURAG GmbH
DURAGIndia
DURAG GmbHKollaustrae 10522453 Hamburg, GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]
DVN DURAG Vertrieb/Service NordKollaustrae 10522453 Hamburg, GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]
DVO DURAG Vertrieb/Service OstMeiner Ring 409599 Freiberg, GermanyTel.+49 (0)3731 30 04-0Fax+49 (0)3731 30 04-22E-Mail: [email protected]
DVS DURAG Vertrieb/Service SdWeidenweg 16
73087 Bad Boll, GermanyTel.+49 (0)7164 912 25-0Fax+49 (0)7164 912 25-50E-Mail: [email protected]
DVW DURAG Vertrieb/Service WestAn der Pnt 53a40885 Ratingen, GermanyTel.+49 (0)2102 74 00-0Fax+49 (0)2102 74 00 28E-Mail: [email protected]
DURAG France S.a.r.l.Parc GIP Charles de Gaulle49, rue Lonard de Vinci, BP 7016695691 Goussainville CEDEX, FranceTel.+33 (0)1 301 811 80Fax+33 (0)1 393 383 60E-Mail: [email protected]
DURAG UK OfficeSuite 17, Brookside Business Park Cold Meece, Stone, StaffordshireST15 0RZ, United KingdomTel.+44 (0)1785 760 007Fax+44 (0)1785 760 014E-Mail: [email protected]
DURAG, Inc., USA1355 Mendota Heights Road Suite 200,Mendota Heights MN 55120, USATel.+1 651 451-1710Fax+1 651 457-7684E-Mail: [email protected]
DURAG India Instrumentation Ltd#143/16, Ground Floor, 4th Main Road
Industrial Town, RajajinagarBengalooru 560 044, IndiaTel.+91 (0)80 23 14 56 26Fax+91 (0)80 23 14 56 26 Ext. 30E-Mail: [email protected]
www.durag.de
DURAG data systems GmbHKollaustrae 105,22453 Hamburg, GermanyTel.+49 (0)3731 30 04-0Fax+49 (0)3731 30 04-22E-Mail: [email protected]
DURAG process & systems technology gmbhKollaustrae 10522453 Hamburg, GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]
Hegwein GmbHAm Boschwerk 770469 Stuttgart, GermanyTel.+49 (0)711 135 788-0Fax+49 (0)711 135 788-5E-Mail: [email protected]
Smitsvonk Holland B.V.P.O. Box 180, 2700 AD ZoetermeerLoodstraat 57, 2718 RV ZoetermeerNetherlandsTel.+31 (0)79 361 35 33Fax+31 (0)79 361 13 78E-mail: [email protected]
VEREWA Umwelt- und Prozessmesstechnik GmbHKollaustrae 10522453 Hamburg, GermanyTel.+49 (0)40 55 42 18-0Fax+49 (0)40 58 41 54E-Mail: [email protected]
smart solutions for combustion and environment
DURAG GROUP 10/2008 Subject to change without notice