brief history - microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h37/...(foam cable...
TRANSCRIPT
Brief HistoryEstablished as KWANG IL Electric
Factory Registration
Approved UL (UL Style No. 1007 Approval for 15 kinds FILE No. 150633)
Approved CSA
Technical Standards Manufacturing industry Registration (Insulation Wire and Cable)
Korean Technical Standards approval for 5 kinds
Incorporated as KWANG IL Electric Co., Ltd.
Korean Technical Standards make an addition approved (Neon Tube)
Moved to Byuk-Jae factory new construction
Made over corporation name as KWANG IL Electric Wire Co., Ltd
Make an addition approval CSA for 4 kinds
Make an addition approval UL (UL Style 1185, 2547 : FILE No. 150633)
Approval Quality Mamagement System Certificate KS A 9001: 2001 / ISO 9001:2000 (Production of Insulation Wire and Cable)
Safety Certification for Electirc and Electronic Appliance Approval Approval for 8kinds(PVC Sheathed Cable)
Safety Certification for Electirc and Electronic Appliance Approval Make an additionapproval for 3 kinds (KIV)
Approved Certificate of Information and Communication Equipment(Foam Cable 5C-HFBT/7C-HFBT)
Approval Quality Mamagement System Certificate KS A 9001: 2001 / ISO 9001:2000 conversion of certification state(Production of Insulation Wire and Cable)
Safety Certification for Electirc and Electronic Appliance Approval (Approval for CVV-SB)
Approved Korean Industrial Makrs (KS C 3304, 3325, 3610)
Make an addition approved Certificate of Information and Communication Equipment(Foam Cable 10C-HFBT)
Make an addition approved UL (UL Style 1571,2789,2969,2990,20276 : FILE No. 150633)
Make an addition approved UL (UL Style 2095 : FILE No. 150633)
Make an addition approved KS (KS C 3330, 3602)
Make an addition approved UL(UL Style 1095, 1569, 2448, 2668, 2725, 2851, 20379 : FILE No. 150633)
Faithful payment of taxes commendation awarding
Change of mark contents KS (KS C IEC 60227-3, 60227-5, 60502-1)
KS A 9001:2001/ISO 9001:2000 System renewal (Production of Insulation wire & Cable)
Approval UL RSCS System & Mark (About RoHS)
Make an addition approved UL (UL Style 1275, 1283 : FILE No. E150633)
Management renovation smaller enterprises Selection
Management renovation smaller enterprises Certification
Approval CCC Mark Certification
Approval Kyonggi-Do Promising Small and medium-sized Enterprise
Make an addition approved UL (UL Style 10483, 21098 : FILE No. 150633)
KS A 9001:2001/ISO 9001:2000 System Renewal (Production of Insulation wire & Cable)
Management renovation smaller enterprises SelectionApproval Environment Management System CertificationKS I ISO 14001:2009/ISO 14001:2004 (Production of Insulation Wire and Cable)
1984. 4. 11990. 12. 131994. 6. 31994. 7. 31995. 12. 291996. 7. 61999. 3. 222000. 1. 12001. 6. 22001. 6. 132003. 3. 162003. 3. 312003. 10. 21
2003. 10. 23
2004. 1. 16
2004. 7. 29
2004. 8. 31
2004. 11. 52005. 3. 3
2005. 4. 21
2005. 5. 6 2005. 6. 22 2005. 9. 142005. 9. 20
2006. 3. 32006. 5. 162006. 9. 202006. 10. 202006. 10. 312006. 11. 012006. 11. 12007. 12. 172008. 10. 132009. 3. 172009. 8. 272009. 10. 222011. 01. 31
UL Style No. 1007 PVC Insulation Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 4
UL Style No. 1015 PVC Insulation Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 5
UL Style No. 1275 Insulation Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 6
UL Style No. 1283 Poly Vinyl Chloride Insulated Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 7
UL Style No. 2464 PVC Jacketed Cable (AME-SB Core Type)₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 8
UL Style No. 2464 PVC Jacketed Cable (AME-SB Pair Type)₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩ 9
UL Style No. 2095 PVC Jacketed Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩10
UL Style No. 2468 Flat Ribbon-Type Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩11
UL Style No. 2919 Overall Shield Low Voltage Computer Cable AME-SB₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩12
UL Style No. 2919 Individual Shield Low Voltage Computer Cable AME-SB₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩13
UL Style No. 2969 Electronic Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩14
UL Style No. 2990 Electronic Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩15
UL Style No. 20276 Electronic Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩16
UL Style No. 21098 600V Jacketed Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩17
UL Style No. 20936 PUR Jacketed Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩18
KS C IEC 60227-5 Ordinary PVC Sheathed Cord₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩19
KS C IEC 60227-3 Heat-Resistant PVC Insulated Flexible Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩20
KS C IEC 60227-3 Insulated Flexible Wire₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩21
KS C IEC 60502-1 (CVV)0.6/1kV PVC Insulated PVC Sheathed Control Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩22
KS C IEC 60502-1 (VCT)0.6/1kV PVC Insulated PVC Sheathed Flexible Power Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩23
KS C 3610 Foam Braid Cable (PE Insulated Shield Type)₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩24
5C-HFBT Telecommunication Satellite Receive Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩25
7C-HFBT Telecommunication Satellite Receive Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩25
10C-HFBT Telecommunication Satellite Receive Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩25
Hoist Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩26
VCT-F Elevator PVC Insulated Complex Rubber Sheathed Flat Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩27
FA Cable₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩₩29
Contents
PVC Insulation Wire
Application of Product
·Internal Wiring of electrical and electronic equipment.
Characteristics of Product
·Rating:(UL) 300V 80·Flammability:VW-1, FT1 Satisfaction·Standard:UL Subject 758,1581·Cerification: Underwriters Laboratories Inc.(R)
Construction & Formation
E150633 AWM 1007 80 300V VW-1 24AWG UL-RoHS RS3674
4 www.kicable.com
UL Style No. 1007
Type
Stranded
3028262422201816
1.151.251.351.451.601.802.002.40
7/0.1027/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
0.4
376.96237.38148.9493.2555.0034.6021.8013.70
2,000
AWG Size ConstructionApprox.Diameter(mm)
Thickness
(mm)
Diameter
(mm)
Max. ConductorResistance at20 (Ω/km)
Min. InsulationResistance
(Ω/km)
DielectricWithstandingVolt. AC V/min
(V)
Conductor Insulation
0.310.380.480.610.760.951.211.53
15
Solid
3028262422201816
1.101.151.201.351.451.651.852.10
1/0.2601/0.3201/0.4041/0.5111/0.6431/0.8131/1.0241/1.290
0.4
361.13227.39142.7989.3954.3033.9021.4013.50
2,000
0.260.320.400.510.640.811.021.29
15
TA-SC(Hiwrap)
28262422
1.251.351.451.60
7/0.1277/0.1607/0.2037/0.260
0.4
222.33138.8885.4154.44
2,000
0.380.480.610.79
15
Conductor Insulation
AWM1007
148.9493.2555.0034.6021.8013.708.625.433.41142.7989.3954.3033.9021.4013.508.455.313.34138.8885.4154.44
5KWANG IL
PVC Insulation WireUL Style No. 1015
Application of Product·Internal Wiring of electrical and electronic equipment.
Characteristics of Product·Rating:(UL) 600V, 105·Flammability:VW-1, FT1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Construction & Formation
KI C
AB
LE
Stranded
262422201816141210
2.102.202.352.602.903.153.454.004.70
7/0.16011/0.16017/0.16021/0.18034/0.18026/0.26041/0.26065/0.260105/0.260
0.8 2,000
0.480.610.760.951.211.531.922.423.19
15
Solid
262422201816141210
2.002.102.302.402.602.903.253.704.20
1/0.4041/0.5111/0.6431/0.8131/1.0241/1.2901/1.6301/2.0501/2.600
0.8 2,000
0.400.510.640.811.021.291.632.052.60
15
TA-SC(Hiwrap)
262422
2.102.202.35
7/0.1607/0.2037/0.260
0.8 2,0000.480.610.79
15
E150633 AWM 1015 105 600V VW-1 24AWG UL-RoHS RS3674
Conductor InsulationAWM1015
TypeAWG Size Construction
Approx.Diameter(mm)
Thickness
(mm)
Diameter
(mm)
Max. ConductorResistance at20 (Ω/km)
Min. InsulationResistance
(Ω/km)
DielectricWithstandingVolt. AC V/min
(V)
Conductor Insulation
PVC Insulation WireUL Style No. 1275
Construction & Formation
6 www.kicable.com
Application of Product·Internal wiring of refrigerating equipment and where
exposed to oil at temperatures not exceeding 60 or 80 if applicable
Characteristics of Product·Rating:600V, 60 & 105·Flammability:VW-1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Type
Stranded
18
16
14
12
10
23.5
14.6
9.15
5.75
3.55
13
11
9
8
6
1.60
1.60
1.60
34/0.180
41/0.160
16/0.260
26/0.260
65/0.160
41/0.260
65/0.260
105/0.260
1.21
1.18
1.17
1.50
1.49
1.88
2.36
3.00
2.83
2.80
2.80
3.12
3.11
3.50
3.98
4.62
2,000
AWGSize Con.
Approx.Diameter
(mm)
Thickness
(mm)
Diameter
(mm)
Max. ConductorResistance at 20 (Ω/km)
Min. InsulationResistance(MΩ/km)
ACWithstandVoltage
(V)
Conductor Insulation
AWM1275
E150633 AWM 1275 60 600V VW-1 24AWG UL-RoHS RS3674
Conductor Insulation
7KWANG IL
KI C
AB
LE
PVC Insulated WireUL Style No. 1283
AWM1283
Construction & Formation
Application of Product·Internal wiring of appliances;or internal wiring of
appliances where exposed to oil at a temperatures not exceeding 60 or 80.
Characteristics of Product·Rating:600V, 105·Flammability:VW-1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Type
Stranded
8
6
4
2
2.23
1.41
0.882
0.555
8
7
6
5
1.65
7/24/0.254
7/38/0.254
7/60/0.254
19/35/0.254
4.41
5.55
6.97
8.88
7.71
8.85
10.30
12.20
3,000
4,000
AWGSize Con.
Approx.Diameter
(mm)
Thickness
(mm)
Diameter
(mm)
Max. ConductorResistance at 20(Ω/km)
Min. InsulationResistance(MΩ/km)
ACWithstandVoltage
(V)
Conductor Insulation
E150633 AWM 1283 105 600V VW-1 8AWG UL-RoHS RS3674
Conductor Insulation
PVC Jacketed Cable(AME-SB Core-Type)
Application of Product· Internal wiring of external interconnection
of electronic equipment. (Such as desk-type calculators, dictating machines, or X-ray equipment.)
Characteristics of Product·Insulation Stranded:UL Style 1061 and 1007 Type Use.·Flexible and electrical character is excellent.·Rating:300V, 80·Flammability:VW-1, FT1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Construction & Formation
Identification Marking:E150633 AWM 2464 80 300V VW-1 24AWG UL-RoHS RS3674
8 www.kicable.com
UL Style No. 2464
2826242220181628262422201816
2~50
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
Semi-RigidPVC 0.25
AL/ps
TapeMin. 70
Tin-coatedcopperstrandedwire
ExtrudedPVC 1.0
0.42
Tin-coatedcopperstrandedwire
1.0AL/ps
Tape2~50
HeatResistancePVC
Min. 70 ExtrudedPVC
AWG Size No. ofpcs
Construction
(mm)Material
Braid coverageof percent(%)
MaterialThickness
(mm)
Drain WireMaterial
Thickness
(mm)Material
Conductor Insulation Shield Sheath
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
AL Tape Sheath
Braid Shield
Drain Wire
Conductor
Insulation
AWM2464
9KWANG IL
PVC Jacketed Cable(AME-SB Pair-Type)UL Style No. 2464
Application of Product·Internal wiring of external interconnection
of electronic equipment. (Such as desk-typecalculators, dictating machines, or X-rayequipment.)
Characteristics of Product·Insulation Stranded:UL Style 1061 and 1007 Type Use.·Flexible and electrical character is excellent.·Rating:300V, 80·Flammability:VW-1, FT1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Construction & Formation
Identification Marking : E150633 AWM 2464 80 300V VW-1 24AWG UL-RoHS RS3674
KI C
AB
LE
2826242220181628262422201816
2~50
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
Semi-RigidPVC 0.25
AL/ps
TapeMin. 70
Tin-coatedcopperstrandedwire
ExtrudedPVC 1.0
0.42
Tin-coatedcopperstrandedwire
1.0AL/ps
Tape2~50
HeatResistancePVC
Min. 70 ExtrudedPVC
AWG Size No. ofpcs
Construction
(mm)Material
Braid coverageof percent(%)
MaterialThickness
(mm)
Drain WireMaterial
Thickness
(mm)Material
Conductor Insulation Shield Sheath
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
Sheath
Braid Shield
Conductor
InsulationAL Tape
Drain Wire
AWM2464
Application of Product·A signal transmission of electronic and electrical equipment.·Fire Alarm Sensor Cable
Characteristics of Product·Flexible is excellent.·Rating:300V, 80·Flammability:VW-1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
2826242220181628262422201816
2~50
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
Semi-RigidPVC 0.25
AL/ps
TapeMin. 70
Tin-coatedcopperstrandedwire
ExtrudedPVC 1.0
0.42
Tin-coatedcopperstrandedwire
1.0AL/ps
Tape2~50
HeatResistancePVC
Min. 70 ExtrudedPVC
AWG Size No. ofpcs
Construction
(mm)Material
Braid coverageof percent(%)
MaterialThickness
(mm)
Drain WireMaterial
Thickness
(mm)Material
Conductor Insulation Shield Sheath
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
AWM2095
UL Style No. 2095
www.kicable.com10
Construction & Formation
PVC Jacketed Cable
Sheath
AL Tape(Foil Shield)
Insulation
Drain WireConductor
E150633 AWM 2095 80 300V VW-1 18AWG UL-RoHS RS3674
KWANG IL 11
KI C
AB
LE
Application of Product·Internal wiring of Audio, Video equipment.
Characteristics of Product·Exactly the same TA copper use. Applicable to both pressure
processing is simplicity. Operation efficiency is excellent.·Flexible and practice area is small.
(Internal wiring of small equipment is facility.)·Rating:300V, 80·Flammability:VW-1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Flat Ribbon Type Cable
Construction & Formation
UL Style No. 2468
2826242220181628262422201816
2~50
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
Semi-RigidPVC 0.25
AL/ps
TapeMin. 70
Tin-coatedcopperstrandedwire
ExtrudedPVC 1.0
0.42
Tin-coatedcopperstrandedwire
1.0AL/ps
Tape2~50
HeatResistancePVC
Min. 70 ExtrudedPVC
AWG Size No. ofpcs
Construction
(mm)Material
Braid coverageof percent(%)
MaterialThickness
(mm)
Drain WireMaterial
Thickness
(mm)Material
Conductor Insulation Shield Sheath
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18026/0.260
P
PnT
W
Conductor
SheathE150633 AWM 2468 80 300V VW-1 24AWG UL-RoHS RS3674
AWM2468
12 www.kicable.com
Low Voltage Computer Cable(EIA RS-422/485 Type)
Application of Product·A signal transmission of electronic com-
puter and electric equipment. ·External interconnection in class 2 cir-
cuits of electronic equipment.·Remote control cord for VTR, TV, Stereo
receiver, etc.·Cord connecting VTR Camera, Viewfind-
er, Audio and Video equipment.
Characteristics of Product·Excellent flexibility·Rating:30V 80·Flammability:VW-1, FT1 Satisfaction·Standard:UL Subject 758,1581·Cerification: Underwriters Laboratories Inc.(R)
Construction & Formation
Identification Marking:E150633 AWM 2919 80 30V VW-1 24AWG UL-RoHS RS3674
UL Style No. 2919 Overall
Pair ofCore
1P2P3P4P6P8P10P15P
0 1.0ExtrudedPVC
RS-422 Type(0.40T)
RS-485Type(0.60T)
Al/psTape
PE&PVC
7/0.1611/0.1617/0.1621/0.1834/0.1826/0.260
Tin-coatedcopper wire
AWG Size ConstructionThickness
(mm)
Materialof TapeMaterial
Conductor Insulation
Drain wireMaterial
Coverage ofpercent % Material
Thickness
(mm)
Shield Sheath
Min. 70
Sheath AL Tape
Conductor
InsulationBraid Shield
Drain Wire
AWM2919
13KWANG IL
KI C
AB
LE
Low Voltage Computer Cable(EIA RS-422/485 Type)UL Style No. 2919 Individual
Construction & Formation
Identification Marking:E150633 AWM 2919 80 30V VW-1 24AWG UL-RoHS RS3674
Application of Product·A signal transmission of electronic computer and elec-
tric equipment. ·External interconnection in class 2 circuits of electronic
equipment.·Remote control cord for VTR, TV, Stereo receiver, etc.·Cord connecting VTR Camera, Viewfinder, Audio and
Video equipment.
Characteristics of Product·Excellent flexibility·Rating:30V, 80·Flammability:VW-1 FT1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Pair ofCore
234567910121618
24AWG(11/0.16TA)
22AWG(17/0.16TA)1.0Extruded
PVC
RS-422 Type(0.40T)
RS-485Type(0.60T)
Al/psTape
PE&PVC
Tin-coatedcopper wire
AWG SizeThickness
(mm)
Materialof TapeMaterial
Conductor Insulation
Drain wireMaterial
Coverage ofpercent % Material
Thickness
(mm)
Shield Sheath
Min. 70
AL Tape Conductor
Insulation
Sheath
Braid Shield
Drain Wire
AWM2919
Electronic CableUL Style No. 2969
Construction & Formation
14 www.kicable.com
Application of Product·A signal transmission of electronic computer and elec-
tric equipment. ·External interconnection of electronic equipment and
computer.·Remote control cord for VTR, TV, Stereo receiver, etc.·Cord connecting VTR Camera, Viewfinder, Audio and
Video equipment.
Characteristics of Product·Rating:30V, 80·Flammability:VW-1 Satisfaction.·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Identification Marking:E150633 AWM 2969 80 30V VW-1 24AWG UL-RoHS RS3674
Pair ofCore
567911151821232530
30AWG
(7/0.102TA)
~
24AWG
(11/0.16TA)
1.0 500Heat-
ResistancePVC
5
0.18
or
0.40
AL/psTape
Semi-RigidPVCorHeat-
ResistancePVC
Tin-Coatedcopperstrandedwire
AWG SizeThickness
(mm)
Materialof TapeMaterial
Conductor Insulation
Drain wireMaterial
Coverageof
percent %Material
Thickness
(mm)
Max.ConductorResistanceat 20(Ω/)
Min.InsulationResistance
(/)
Shield Sheath
Min. 70
Sheath
AL Tape
Conductor
Insulation
Braid Shield
Drain Wire
AWM2969
15KWANG IL
KI C
AB
LE
Electronic Cable
Construction & Formation
UL Style No. 2990
Application of Product·A signal transmission of electronic computer and electric
equipment. ·Interconnection of monitor and main body of computer.·Remote control cord for VTR, TV, Stereo receiver, etc.·Cord connecting VTR Camera, Viewfinder, Audio and
Video equipment.
Characteristics of Product·Rating:30V, 80·Flammability:VW-1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Identification Marking:E150633 AWM 2990 80 30V VW-1 26AWG UL-RoHS RS3674
Style/No. ofcores
AWGSize
Con.
(mm)
Approx.Dia.(mm)
MaterialApprox.Dia.(mm)
Wrapshielddia.
(mm)Material
Approx.Dia.(mm)
Assem-
bly
AL/psTapeThick.
(mm)
DrainWire
(No./mm)
Wireof Dia(mm)
Coverageof % Material
Approx.Dia.(mm)
UL Style1354×3C1533×3C
28 7/0.127 0.38 PE 0.50 0.12TA
Heat-Resis-tancePVC
0.33
9C
0.0257/0.16TA
0.12TA Min. 70
Heat-Resis-tancePVC
1.07/0.16 0.48SR-PVC
0.25 - - -
7/0.16 0.48SR-PVC
0.25 - - - 12C
26
26
UL Style1061×6C1571×6C
UL Style1061×9C1571×6C
Conductor Insulation Inner jacket Shield Sheath
Sheath
Insulation
AL TapeUL Style No. 1354 or 1533
UL Style No. 1061 or 1571
Conductor
Braid Shield
Braid Shield
Drain Wire
AWM2990
Electronic CableUL Style No. 20276
Construction & Formation
16 www.kicable.com
Application of Product·Internal wiring or external interconnection of electronic equip-
ment in Class 2 circuit.·LCD Monitor Cable.
Characteristics of Product·Rating:30V, 80·Flammability:VW-1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Pair ofCore
578910111215182125
30AWG(7/0.102TA)
~24AWG(11/0.16TA)
1.0 500PVC 50.10~0.25
AL/psTape
Semi-RigidPVCorHeat-
ResistancePVC
Tin-Coatedcopperstrandedwire
AWG SizeThickness
(mm)
Materialof TapeMaterial
Conductor Insulation
Drain wireMaterial
Coverageof
percent %Material
Thickness
(mm)
Max.ConductorResistanceat 20(Ω/)
Min.InsulationResistance
(/)
Shield Sheath
Min. 70
SheathAL Tape
ConductorBraid Shield
Insulation
E150633 AWM 20276 80 30V VW-1 30AWG UL-RoHS RS3674
AWM20276
17KWANG IL
KI C
AB
LE
600V PVC Jacketed CableUL Style No. 21098
Application of Product·External interconnection or internal wiring of
electronic equipment.
Characteristics of Product·Rating:600V, 90·Flammability:VW-1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
Identification Marking:E150633 AWM 21098 90 600V VW-1 24AWG UL-RoHS RS3674
Pair ofCore
28262422201816
2~50 Acc. tostandard
ExtrudedPVC
Acc. tostandard
Al/psTapePVC
7/0.1277/0.16011/0.16017/0.16021/0.18034/0.18054/0.180
Tin-coatedcopperstandardwire
AWG Size ConstructionThickness
(mm)MaterialMaterial
Conductor Insulation
Drain wireMaterial
Braid coverageof percent(%)
MaterialThickness
(mm)
Shield Sheath
Min. 70
Construction & Formation
AL Tape Sheath
Braid Shield
Drain Wire
Conductor
Insulation
AWM21098
PUR Jacketed Cable
Application of Product·Internal wiring or external interconnection of
electronic equipment.
Characteristics of Product·Rating:300V 80·Flammability:VW-1 Satisfaction·Standard:UL Subject 758, 1581·Cerification: Underwriters Laboratories Inc.(R)
18 www.kicable.com
UL Style No. 20936
Construction & Formation
(Filler Type) (AM-SB Type)
(Double Cover Type)
AL Tape
Sheath
Braid Shield
Conductor)
Insulation
Conductor
Sheath
1st.Sheath
Braid Shield
Conductor
Insulation
(2st.Sheath
Identification Marking:E150633 AWM 20936 80 300V VW-1 24AWG UL-RoHS RS3674
AWM20936
26.019.513.37.98
19KWANG IL
KI C
AB
LEKS C IEC 60227-5
Ordinary PVC Sheathed CordVCTF
Construction & Formation
NominalSectionalArea()
2×0.752×1.02×1.52×2.5
5
5.75.96.88.4
0.0110.0100.0100.009
0.210.210.260.26
0.60.60.70.8
0.80.80.81.0
7.27.58.610.6
26.720.013.78.21
ConductorClass
MaximumDiameterof Wire(mm)
Approx.Diameter
(mm)
InsulationThickness
(mm)
SheathThickness
(mm)MinimunValue
(mm)
MaximumValue
(mm)
Copper
(Ω/)
Tin-coatedcopper
(/)
70
(/)
Conductor Mean Overall Diameter Max. ConductorResistance at 20
InsulationResistance
3×0.753×1.03×1.53×2.5
5
6.06.37.49.2
0.0110.0100.0100.009
0.210.210.260.26
0.60.60.70.8
0.80.80.81.0
7.68.09.411.4
1.11.31.62.1
26.019.513.37.98
4×0.754×1.04×1.54×2.5
5
6.67.18.410.1
0.0110.0100.0100.009
0.210.210.260.26
0.60.60.70.8
0.80.80.81.0
8.39.010.512.5
26.720.013.78.21
1.11.31.62.1
26.019.513.37.98
5×0.755×1.05×1.55×2.5
5
7.47.89.311.2
0.0110.0100.0100.009
0.210.210.260.26
0.60.60.70.8
0.80.80.81.0
9.39.811.613.9
26.720.013.78.21
1.11.31.62.1
26.019.513.37.98
1.11.31.62.1
26.720.013.78.21
KS C 3304 60227 KS IEC 53 2.5×4C KWANG IL
Used ColorNo. of Core
1Core2Core3Core4Core5Core
Sky_BlueSky_Blue, BrownGreen/Yellow, Sky_Blue, BrownGreen/Yellow, Sky_Blue, Brown, BlackGreen/Yellow, Sky_Blue, Brown, Black, Dark_Brown
·Standard:KS C IEC 60227-5(Before : KS C 3304)·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
KSCIEC60227-5
Conductor
Insulation
Sheath
Application of Product·This cords is widely used in electrical,
electron, sound, lighting etc electrical homeapparatus under AC 300/500V.
Characteristics of Product·Rating:Volt.(max.) 300/500V,
Temp.(max.) 70·Core identification(According to C IEC 60227-1)
20 www.kicable.com
KS C IEC 60227-3
Heat-Resistant PVC Insulated Flexible Wire
Application of Product·This cords is Widely used in electrical home apparatus under
AC 300/500V for its flexibility, insulation easy colouring andbeautiful external appearance.
Characteristics of Product·Rating:Volt.(max.) 300/500V, Temp.(max.) 90·Insulation Color : Black, Yellow, Sky_Blue, Green, Brown·Standard:KS C IEC 60227-3(Before : KS C 3304)·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
Construction & Formation
VSF
NominalSectionalArea()
0.5
0.75
1.0
1.5
2.5
5
2.1
2.2
2.4
2.8
3.4
0.013
0.012
0.010
0.009
0.009
0.21
0.21
0.21
0.26
0.26
0.6
0.6
0.6
0.7
0.8
2.5
2.7
2.8
3.4
4.1
40.1
26.7
20.0
13.7
8.21
ConductorClass
MaximumDiameterof Wire(mm)
Approx.Diameter
(mm)
InsulationThickness
(mm)
MinimunValue
(mm)
MaximumValue
(mm)
Copper
(Ω/)
Tin-coatedcopper
(/)
90
(/)
Conductor Mean Overall Diameter Max. ConductorResistance at 20
InsulationResistance
0.9
1.1
1.3
1.6
2.1
39.0
26.0
19.5
13.3
7.98
KS C IEC 60227-3 VSF 90 2.5 KWANG IL
Conductor
Insulation
-3 VSF 90 2.5 KWANG IL
KS C IEC 60227
21KWANG IL
KI C
AB
LEKS C IEC 60227-3
Insulated Flexible Wire
Application of Product·This wire is suitable for wiring on switch on switch boards,
panel boards and control apparatus under AC 450/750V.
Characteristics of Product·Rating:Volt.(max.) 450/750V, Temp.(max.) 70·Insulation Color : Black, Yellow, Sky_Blue, Green, Brown·Standard:KS C IEC 60227-3(Before : KS C 3325)·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
Construction & Formation
KIV
NominalSectionalArea()
1.5
2.5
4.0
6.0
5
2.8
3.4
3.9
4.4
0.010
0.009
0.007
0.006
0.26
0.26
0.31
0.31
0.7
0.8
0.8
0.8
3.4
4.1
4.8
5.3
13.7
8.21
5.09
3.39
ConductorClass
MaximumDiameterof Wire(mm)
Approx.Diameter
(mm)
InsulationThickness
(mm)MinimunValue
(mm)
MaximumValue
(mm)
Copper
(Ω/)
Tin-coatedcopper
(/)
90
(/)
Conductor Mean Overall Diameter Max. ConductorResistance at 20
InsulationResistance
1.6
2.1
2.6
3.6
13.3
7.98
4.95
3.30
KS C IEC 60227-3 KIV 6.0 KWANG IL
Conductor
Insulation
KIV6.0
KWANGIL
KS C IEC 60227-3
22 www.kicable.com
0.6/1kV PVC Insulated PVC SheathedControl Cable
CVV
No. OfCores
2
1.52.54.06.010
0.80.81.01.01.0
3.52
1.592.012.553.124.05
1.8
12.17.414.613.081.83
NominalSectionalArea()
ConductorClass Construction
Approx.Diameter
(mm)
InsulationThickness
(mm)
SheathThickness
(mm)
MeanOverallDiameter
Max. ConductorResistanceat 20
(Ω/)
TestVoltage
(KV)
Conductor
7/0.537/0.677/0.857/1.047/1.35
11.012.014.015.017.0
3
1.52.54.06.010
0.80.81.01.01.0
3.52
1.592.012.553.124.05
1.8
12.17.414.613.081.83
7/0.537/0.677/0.857/1.047/1.35
11.512.514.516.018.0
4
1.52.54.06.010
0.80.81.01.01.0
3.52
1.592.012.553.124.05
1.8
12.17.414.613.081.83
7/0.537/0.677/0.857/1.047/1.35
12.513.516.017.019.5
Application of Product·This cable is used for control circuits in under-
ground duct, conduit and open air under 0.6/1kV.
Characteristics of Product·Rating:Volt.(max.) 0.6/1kV
Temp.(max.) 70
Construction & Formation
·Core identification
·Standard:KS C IEC 60502-1(Before : KS C 3330)·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
KS C IEC 60502-1 CVV 0.6/1KV 6.0 x 4C KWANG IL
Conductor
Insulation
PS Tape Sheath
KS CIEC60502-1
KS C IEC 60502-1
Used ColorNo. of Core
2Core3Core4Core
Black, WhiteBlack, White, RedBlack, White, Red, Green
23KWANG IL
KI C
AB
LEKS C IEC 60502-1 0.6/1kV PVC Insulated PVC Sheathed
Flexible Power Cable
Construction & Formation
VCT
NominalSectionalArea()
2×1.02×1.52×2.52×4.02×6.0
5 1.8 3.5
0.210.260.260.310.31
0.80.80.81.01.0
10.010.511.513.515.5
20.013.78.215.093.39
ConductorClass
MaximumDiameterof Wire(mm)
Approx.Diameter
(mm)
InsulationThickness
(mm)
SheathThickness
(mm)
MeanOverallDiameter
Copper
(Ω/)
Tin-coatedcopper
(/)
TestVoltage
(KV)
Conductor Max. ConductorResistance at 20 (Ω/)
1.31.62.12.63.6
19.513.37.984.953.30
3×1.03×1.53×2.53×4.03×6.0
5 1.8 3.5
0.210.260.260.310.31
0.80.80.81.01.0
10.511.012.014.016.0
20.013.78.215.093.39
1.31.62.12.63.6
19.513.37.984.953.30
4×1.04×1.54×2.54×4.04×6.0
5 1.8 3.5
0.210.260.260.310.31
0.80.80.81.01.0
11.012.013.015.017.5
20.013.78.215.093.39
1.31.62.12.63.6
19.513.37.984.953.30
Application of Product·This cable is generally used for connecting mo-
bile electric apparatus under AC 0.6/1kV aspower source lead wire in factory, mine areaand farm.
Characteristics of Product·Rating:Volt.(max.) 0.6/1kV, Temp.(max.) 70
Used ColorNo. of Core
2Core3Core4Core
Black, WhiteBlack, White, Red orBlack, White, GreenBlack, White, Red, Green
·Core identification
·Standard:KS C IEC 60502-1(Before : KS C 3602)·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
KS C IEC 60502-1 VCT 0.6/1KV 6.0 ×4C KWANG IL
SheathInsulation
Conductor
KSCIEC60502-1
24 www.kicable.com
Foam Braid Cable (PE Insulated Shield Type)
C 3610
Construction & Formation
Application of Product·This cable is generally used for inner wire, connection of high
frequency. An antenna input TV and CATV used.
Characteristics of Product·75ΩType. Signal distortion prevention excellent.·RF System suitability.·Standard:KS C 3610·Cerification: Korean Industrial Standards
Safety Certification for Electric and Elec-tronic Appliance
SymbolNo./
Approx.Dia.
()
Thick-ness
()
Approx.Dia.
()
Dia.eachline()
지 수 타 수
Pitch
()
Approx.Dia.
()
Thick-ness
()
Approx.Dia.
()
1.5C-2V
2.5C-2V
3C-2V
3C-2VCS
3C-2VS
5C-2V
7C-2V
10C-2V
1/0.26 0.26 0.67 1.6 0.10 5 16 16 2.1 0.4 2.9 2.9±0.4 968 69±4 96
1/0.4 0.4 1.0 2.4 0.12 6 16 20 3.0 0.5 4.0 4.0±0.5 145 69±4 52
1/0.5 0.5 1.3 3.1 0.14 3.8 0.8 5.4 5.4±0.5 91.4 67±3 42
1/0.5 0.5 1.3 3.1 0.14 3.8 0.8 5.4 5.4±0.5 256 67±3 42
7/0.18 0.54 1.28 3.1 0.14 3.8 0.8 5.4 5.4±0.5 100 67±3 48
1/0.8 0.8 2.05 4.9 0.14 5.6 0.9 7.4 7.4±0.5 35.9 67±3 27
7/0.4 1.2 3.05 7.3 0.18 8.2 1.1 10.4 10.4±0.5 20.7 67±3 22
7/0.5 1.5 3.95 9.4 0.20 10.4 1.3 13.0 13±0.6 13.1 67±3 18
Inner Conductor Insulation Sheath Ap-prox.overallDia.
()
(/)Attenu-ation(/20)
Maxi-mumConduc-torResis-tanceDC 20Ω/
Outer Conductor
5 24 268 16 265 24 268 16 265 24 268 16 267 24 4210 16 308 24 4510 16 2510 24 6010 16 22
KS C 3610 ECX 5C-2V KWANG IL
Insulation
Braid Shield Sheath
시스체(Sheath)
Conductor
5C-2V
25KWANG IL
KI C
AB
LETelecommunication satellite receive cable
Construction & Formation
5C, 7C, 10C-HFBT
Application of Product·Interconnection of Satellite Broadcast
television and attachmentmachines used to receive.·Reflection signal transmission system and
Data transmission etc are available.
Characteristics of Product·Vast Hi-Fi cable, character of low-loss.·Voltage standing wave ratio is excellent, transmission loss is
small.·The cables are estate wave rate excellent, transfer damage is
low and deformation is low.·Connect dealing with easy.·In accordance with double shield that microwave leakage is
nothing.·Cerification: Director General of Raidio Research Labo-
ratory Ministry of Information and Commu-nication Republic of Korea
Identification Marking: T-D41-04-0277 5C-HFBT KWANG ILT-D41-04-0276 7C-HFBT KWANG ILT-D41-05-0120 10C-HFBT KWANG IL
ProductName
TypeApprox.Dia.()
MaterialThick-ness()
Approx.Dia.()
Con-struction
Thick-ness()
250 770 Approx.Dia.()
Imped-ance(Ω)
Capaci-tance(/m)
Inner Conductor Outer Con.insulation Sheath Diminution Quantity
5C-HFBT solid 1.2 1.90 5.0 0.85 7.50 99 185
7C-HFBT solid 1.8 2.75 7.3 1.07 10.2 71 124
10C-HFBT solid 2.4 3.50 9.4 1.11 12.6 54 99
foaming
P E
AL/ps +B.S +AL/ps
75±3 55
Insulation
Conductor
Braid Shield
AL Tape
Sheath
5C-HFBT
26 www.kicable.com
Type
Hoist Cable (Electric Power Cable)Hoist Cable
Pair of
Core
3
4
5
6
7
8
10
12
15
10.0
10.5
11.0
12.5
12.5
13.0
14.5
15.0
16.0
NominalSectionalArea()
Construc-tion(No./)
Approx.Dia.()
Thickness()
Approx.Dia.()
Thick. ofSheath()
Approx.Overall Dia.()
ConductorResistanceDC 20(Ω/)
InsulationResistanceDC 20(/)
MessengerWire
()
Conductor Insulation
Application of Product
·The hoist wiring (typically below 600V) andthe power circuit of the moving parts.
Characteristics of Product·The reinforced wire is attached to it, so the
strength of it is increased, and it is sheathed by thePVC mixed with the synthetic rubber, so it has agood flexibility and bending-resistance.
Construction & Formation
1.25 50/0.18 1.5 0.6 2.7 2.5 15.1 50깡선와이어
1.65
Insulation
Massenger Wire
Sheath
Conductor
Paper Tape
KWANGIL KWANG
IL
KWANG IL HOIST CABLE
27KWANG IL
KI C
AB
LEElevator PVC Insulated Complex Rubber
Sheathed Flat Cable
VCT-F
Application of Product·For the place where take place much of rep-
etition of movement like elevator lightingequipment of stage superior in bending-re-sistance to disconnection resistance.
Characteristics of Product·Conductor:Annealed bunched copper wire·Insulation:VW-1, FT1 Satisfaction·Standard:PVC·Referenc Standard : KS C 3609
Construction & Formation
Insulation SheathConductor
VCT-F OSQ×OC KWANG IL RoHS -LF-
VCT-FKWANG
IL
VCT-FKWANG
IL
VCT-FKWANG
IL
28 www.kicable.com
7x327x4213x488x208x349x259x449x5510x3012x4015x46
8x34
12x42
12.5x44
10x38
12x45
12.5x47
7x327x4213x488x208x349x259x449x55
8x34
12x42
12.5x44
9.5x38
12x45
12.5x47
29KWANG IL
KI C
AB
LE
Product StanardConstruction()
Diameter()
First Conductor Second Conductor First Insulation Second InsulationConstruction()
Diameter()
Thickness()
Diameter()
Thickness()
Diameter()
Wire of di-ameter ()
단위 : mm
CoverageConstruction
Thickness()
Diameter()
Conductor Insulation Shield Sheath
60/0.08 0.71 40/0.08 0.58 0.29 1.30 0.26 1.00 0.12 7/16 1.10 7.50
60/0.08 0.71 40/0.08 0.58 0.29 1.30 0.26 1.00 0.12 8/16 1.10 7.50
21/0.18 0.95 11/0.16 0.61 0.25 1.45 0.26 1.10 0.12 9/16 1.10 8.20
40/0.08 0.58 - - 0.26 1.10 - - 0.12 7/24 1.25 10.00
40/0.08 0.58 - - 0.26 1.10 - - 0.12 0/24 1.40 12.50
40/0.08 0.58 - - 0.26 1.10 - - 0.12 8/16 1.20 8.00
7/14/0.08 1.05 - - 0.32 1.70 - - 편조 & 시스는선심별 구분.
7/20/0.08 1.25 - - 0.37 2.00 - - 편조 & 시스는선심별 구분.
UL 2969 HFRGOVV-SB0.3SQx5C+0.2SQx1P
UL 2969 HFRGOVV-SB0.3SQx5C+0.2SQx2P
UL 2969 HFRGOVV-SB0.5SQx6C+0.2SQx3P
UL 2969 HFRGOVV-SB0.2SQx10P
UL 2969 HFRGOVV-SB0.2SQx50C
UL 2969 HFRGOVV-SB0.2SQx5P
UL 2969 HFRGOVV-SB0.5SQx2~50C
UL 2969 HFRGOVV-SB0.75SQx2~50C
Wire & Cable
Flexible Non Shielded & Flexible Shielded
HFRCOVV (Series) & HFRGOVV (Series) /HFRROVV (Series)
Factory Automation
Application of Product· Used in fixed part and ultra-thin operation part assignal-transmit or motor-control of machines usedin factory automation.
· As a wire used in industry robot, power supply ofautomation machines and motor-control, suitablefor fixed wire or the less mobile wire and dividedinto signal-control
Characteristics of Product· An ultra-thin stranded wire is used as conductor.· A heat-resistant PVC in used for insulating material.· A good noise-resistance.· Flexibility and bending-resistance is good.· The soft PVC having a good oil-resistance is suitable for the sheath material. · Easy to handle with.· Endurable material characterizing supreme oil-resistance,wear-resistance and chemistry-resistance.
30 www.kicable.com
Material Symbol Material Name Material Symbol Material Name
V Poly Vinyl Chloride FH Flour
E Poly Ethylene T TPE
IRE Cross Poly Ethylene U Poly Urethane
HFPO Halogen Free Poly Ethylen HFU Halogen Free Urethane
About Factory Automation Wire & Cable
Robot cables that operate repetitively and are used for cables for sending signals be-tween management operation rooms and FA equipment
Summary of the Factory Automation Cable
Composite conductors using ultra fine lines are used to tolerate long-term repetitive move-ments. Since irradiation cross-linking is performed and highly functional materials are edand used, the durability of the insulation has been improved. The internal core of ROFHU ismade of Teflon, which has a high mechanical strength. The skin of ROFHU is made ofurethane, which also has high strength and is grease proof. Thus, it enables 10 millionrepetitive movements to ensure high quality.
Character of the Factory Automation Cable
Material of the Factory Automation Cable
• 90。Left & Right Bending TestCondition] Load weight = 500g // Bending radius(R) = Cable diameter x 10 // speed= 40 Cycle /minResult] Able to identify the time when thickness of 시스체 started to wear away
• U-Bending TestCondition] Stroke length = 1,500 // Bending radius(R) = Cable diameter x 6 // No.of Bedings = 60 Cycle / min
// Acceleration = 2G (20m/ s2) // Speed : 2.0 m/sResult] Able to identify the time when unevenness on the surface of wire or cablehappened.
• Torsion TestCondition] Load Weight = 250g // Torsion angle = ± 360o // Length = 1,000 //Speed = 60 Cycle /minResult] Able to identify the time when crack on wire or cable happened
Reliance of the Factory Automation Cable
31KWANG IL
KI C
AB
LE
About Factory Automation Wire & Cable
Use of the Factory Automation Cable
Item Use
Signal High-speed
Power High-speed
Signal Low-speed
Power Low-speed
Signal
Signal
Power
Signal
Power
Half fixed
Half fixed
Moving
Fixed
Fixed
Fixed
Fixed
ApplicationProperty
Recommended for Ultra-Proof-Bending-Character Cable or SpiralCable to tolerate strong stress by trosion or bending as movingpart
Recommended for Proof-Bending-Character Cable to tolerate lightstress
Recommend for cable requring flexiblity for use as lead wire con-troling operation
Recommend for fixed or moving cable as connecting cable foreach machinery or equipment
Recommend for wire or cable equipped inside control machinery
HFRROTV,HFRROTVUHFRROVV,HFRROTVHFRROTV,HFRROTVUHFRROVV,HFRROTVHFRGOVV,HFRROVVHFRROVVU,HFRROTVUUL 2464, 2969,HFRGOVVHFRROVVU,HFRROTVU
VCT, CV, CVV
PVC Cable
PVC Cable
PerqualificationStatements
33KWANG IL
Business License ……………………………………………………………… 34
Factory License ………………………………………………………………… 35
Kyonggi-Do Smaller Enterprise Certification………………… 36
KS Q ISO 9001:2009/ISO 9001:2008……………………………………… 37
KS I ISO 14001:2009/ISO 14001:2004……………………………………… 38
KS Mark indication Certification Product List………………… 39- KS C IEC 60227-3 (Before Standard : VSF, KIV)
- KS C IEC 60227-5 (Before Standard : VCTF))
- KS C IEC 60502-1 (Before Standard : CVV, VCT)
- KS C 3610 (ECX 5C-2V, 7C-2V, 10C-2V etc)
Electric Product Safe License List…………………………………… 43- VCT - 15 N-EV
- CV (Multi Core) - KIV
- CV (Single Core) - HIV
- CVV - IV
- TFR CVV - TFR CVV-SB
- VCTF
UL Product License List…………………………………………………… 54- (UL) AWM FUII License
- RSCS System & Mark License (About RoHS)
Certificate of Information and Communication Equipment………… 56- 5C-HFBT
- 7C-HFBT
- 10C-HFBT
The List of Certificate of Trademark Registration……………… 60- H.FRROVV
- H.FRROVVU
- H.FRROIREU
- H.FRROIREVU
- H.FRROFHV
- H.FRROFHU
- H.FRROFHVU
Contents