brick house brochure section 6 deep chamber
TRANSCRIPT
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
1/6
CI/SfB Xh(5-)
MAY 2008
STEELWAY
Brickhouse
P R O D U C T M A N U A L
Fabricated Steel
E X P E R T S I N S T E E L
INTERNAL RECESSED PRODUCTS / EXTERNAL RECESSED PRODUCTS / SOLID TOP PRODUCTS / SOLID TOP
HINGED PRODUCTS / DEEP CHAMBER PRODUCTS / LPCB APPROVED / HIGH SECURITY PRODUCTS / ACCESSORIES
KM36158 BS EN 124
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
2/6
39
Section 6 DEEP CHAMBER PRODUCTS
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
3/6
DEEP CHAMBER PRODUCTS GUARDSMAN
40
Key features of range:
External barrier (chain or solid)
Cable flap
Raised treadpattern
Slide out safety grid
During the cover opening sequence theoperative is:
i) Constantly shielded from theopen chamber
ii) Able to maintain a stable foot positioniii) Able to leave the safety barrier in place
during equipment maintenance
Equipment only needs to be hoisted300mm above the open chamber beforethe cover can be closed to provide a safeworking platform
Quick-assembly post and chain safety barrier
Solid barrier option available (Suffix ST)
When fully open the cover is retained in
position by a foot operated safety catch
Internal mechanisms, hinges etc, fordebris-free, tamper-proof performance
Power cables need to be isolated but notdisconnected during maintenance as an
integral flap in the frame allows the cablesto pass through when the cover is in aclosed position
Easy installation through built-in jackingpoints on the frame
Padlock facility as standard
GUARDSMANPRODUCT REGULATIONS
The GUARDSMAN successfully controls
almost all of the major hazards
associated with equipment retrieval
from the open chamber.
This was achieved by carrying out a
risk assessment analysis under The
management of Health and Safety at
Work Regulations, which requires all
employers to assess the risks to their
employees at work.
Steelway Brickhouse identified
the following hazards common with
this activity:
Falls from height
Lifting operations
Confined spaces
Trip hazards
Lifting Operations and Lifting EquipmentRegulations LOLER
The GUARDSMAN is believed to be the only cover
in its class to satisfy the LOLER code of practice for
working platforms.
Manual Handling Operation Regulations
The GUARDSMAN eliminates the need to
uncomfortably stoop or twist while operating
the cover.
Construction (Design and Management)
Regulations
The GUARDSMAN has been designed to reduce
the hazards faced by operatives carrying out
maintenance work on retrieved equipment.
Steelway Brickhouse cannot eliminate the confined
space but the unique opening action means that
access equipment can be positioned before the cover
is opened.
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
4/6
Section C C rebate
430mm
115
mm
Chamberclear opening
Cover clear
opening
DEEPCHAMBERPRODUCT
S
Section6
41
GUARDSMAN SINGLE COVEREasy slide, pivoting access chamber cover and frame.Galvanised to BS EN ISO 1461
PRODUCT CODE
Clear opening (mm) 800 900 1000
800 XG8080B/G
900 XG9080B/G XG9090B/G
1000 XG1080B/G XG1090B/G XG1010B/G
1100 XG1180B/G XG1190B/G XG1110B/G
1200 XG1280B/G XG1290B/G XG1210B/G
1300 XG1380B/G XG1390B/G XG1310B/G
1400 XG1480B/G XG1490B/G XG1410B/G
1500 XG1580B/G XG1590B/G XG1510B/G
FACTA CLASS
B
SLOW-MOVINGWHEEL LOAD
5T
Clear cover opening
SeeGuardsman sizes
Sectional elevation
Plan on cover frame
Rebate = clear cover opening + 610mm
Clear cover opening
See alternative rebate
section details
Framedepth100mm
Clear
coveropening
Rebate=clearc
overopening+300mm
Rebatedepth115mm
Rebate
Padlock boxCable
lock
CC
B B
A
A
115
mm
Clear cover opening
and chamber opening
Section A Arebate
Section B B rebate
150mm
115
mm
Clear cover opening
and chamber opening
180mm
Solid barrier = Suffix /ST Chains = Suffix /C.
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
5/6
Section C C rebate
430mm
115mm
Clear coveropening
and chamberopening
42
GUARDSMAN DOUBLE UNIT COVEREasy slide, pivoting access chamber cover and frame.Galvanised to BS EN ISO 1461
Clear opening1830 1930 2030 2130 2230(mm)
800 XG18380B/G XG19380B/G XG20380B/G XG21380B/G XG2238 0B/G
9 00 XG1 83 90 B/ G XG1 93 90B /G XG2 03 90 B/ G XG 213 90 B/ G XG 22 390 B/ G
1000 XG18 310B /G XG19310B/G XG20310B/G XG21310B /G XG22310B/G
1100 XG18311B/G XG19311B /G XG20311B/G XG21311B/G XG22311B/G
1200 XG18 312B /G XG19312B/G XG20312B/G XG21312B /G XG22312B/G
1300 XG18313B /G XG19313B/G XG20313B/G XG21313B /G XG22313B/G
1400 XG18 314B /G XG19314B/G XG20314B/G XG21314B /G XG22314B/G
1500 XG18 315B /G XG19315B/G XG20315B/G XG21315 B/G XG22315B/G
FACTA CLASS
B
SLOW-MOVINGWHEEL LOAD
5T
Clear cover opening
Sectional elevation
Plan on cover frame
Section A A rebate
Clear cover opening
and chamber opening
115mm
150mm
See alternative rebate section detail
Padlock box
Padlockbox
Remote supportframe
Overall clear cover opening
Rebate = clear cover opening + 860mm
Cable flap
Rebate
Rebate=clearcover
Opening+300mm
= =
Stanchion socket and clearoverall cover opening
Framedepth
100mmRebatedepth115mm
A
A
C
CC
C
230mm
Clearcoveropening
Solid barrier = suffix /ST. Chains = Suffix /C.
All features as per singleunit on page 40
Removable centre beamto give full access tothe chamber
PRODUCT CODE
-
8/2/2019 Brick House Brochure Section 6 Deep Chamber
6/6
Brickhouse Lane, West Bromwich
West Midlands B70 0DY
Tel: 0121 521 4500 Fax: 0121 521 4551
Email: [email protected]
www.steelway.co.uk
STEELWAY
Brickhouse
E X P E R T S I N S T E E L
Steelway is a leading
engineering and fabrication
company that specialises in the
manufacture of steel, aluminium
and GRP products.
Our dedicated workforce prides
itself on its professionalism and
the quality finish of the productsproduced. We strive to be
experts in our field.KM36158 BS EN 124 LPS1175 (LEVEL 4)CERTIFICATE No.
FS533713 BSENISO9001
CERTIFICATE No.
EMS533715 BSENISO14001