brick house brochure section 6 deep chamber

Upload: laura-eddowes

Post on 05-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    1/6

    CI/SfB Xh(5-)

    MAY 2008

    STEELWAY

    Brickhouse

    P R O D U C T M A N U A L

    Fabricated Steel

    E X P E R T S I N S T E E L

    INTERNAL RECESSED PRODUCTS / EXTERNAL RECESSED PRODUCTS / SOLID TOP PRODUCTS / SOLID TOP

    HINGED PRODUCTS / DEEP CHAMBER PRODUCTS / LPCB APPROVED / HIGH SECURITY PRODUCTS / ACCESSORIES

    KM36158 BS EN 124

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    2/6

    39

    Section 6 DEEP CHAMBER PRODUCTS

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    3/6

    DEEP CHAMBER PRODUCTS GUARDSMAN

    40

    Key features of range:

    External barrier (chain or solid)

    Cable flap

    Raised treadpattern

    Slide out safety grid

    During the cover opening sequence theoperative is:

    i) Constantly shielded from theopen chamber

    ii) Able to maintain a stable foot positioniii) Able to leave the safety barrier in place

    during equipment maintenance

    Equipment only needs to be hoisted300mm above the open chamber beforethe cover can be closed to provide a safeworking platform

    Quick-assembly post and chain safety barrier

    Solid barrier option available (Suffix ST)

    When fully open the cover is retained in

    position by a foot operated safety catch

    Internal mechanisms, hinges etc, fordebris-free, tamper-proof performance

    Power cables need to be isolated but notdisconnected during maintenance as an

    integral flap in the frame allows the cablesto pass through when the cover is in aclosed position

    Easy installation through built-in jackingpoints on the frame

    Padlock facility as standard

    GUARDSMANPRODUCT REGULATIONS

    The GUARDSMAN successfully controls

    almost all of the major hazards

    associated with equipment retrieval

    from the open chamber.

    This was achieved by carrying out a

    risk assessment analysis under The

    management of Health and Safety at

    Work Regulations, which requires all

    employers to assess the risks to their

    employees at work.

    Steelway Brickhouse identified

    the following hazards common with

    this activity:

    Falls from height

    Lifting operations

    Confined spaces

    Trip hazards

    Lifting Operations and Lifting EquipmentRegulations LOLER

    The GUARDSMAN is believed to be the only cover

    in its class to satisfy the LOLER code of practice for

    working platforms.

    Manual Handling Operation Regulations

    The GUARDSMAN eliminates the need to

    uncomfortably stoop or twist while operating

    the cover.

    Construction (Design and Management)

    Regulations

    The GUARDSMAN has been designed to reduce

    the hazards faced by operatives carrying out

    maintenance work on retrieved equipment.

    Steelway Brickhouse cannot eliminate the confined

    space but the unique opening action means that

    access equipment can be positioned before the cover

    is opened.

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    4/6

    Section C C rebate

    430mm

    115

    mm

    Chamberclear opening

    Cover clear

    opening

    DEEPCHAMBERPRODUCT

    S

    Section6

    41

    GUARDSMAN SINGLE COVEREasy slide, pivoting access chamber cover and frame.Galvanised to BS EN ISO 1461

    PRODUCT CODE

    Clear opening (mm) 800 900 1000

    800 XG8080B/G

    900 XG9080B/G XG9090B/G

    1000 XG1080B/G XG1090B/G XG1010B/G

    1100 XG1180B/G XG1190B/G XG1110B/G

    1200 XG1280B/G XG1290B/G XG1210B/G

    1300 XG1380B/G XG1390B/G XG1310B/G

    1400 XG1480B/G XG1490B/G XG1410B/G

    1500 XG1580B/G XG1590B/G XG1510B/G

    FACTA CLASS

    B

    SLOW-MOVINGWHEEL LOAD

    5T

    Clear cover opening

    SeeGuardsman sizes

    Sectional elevation

    Plan on cover frame

    Rebate = clear cover opening + 610mm

    Clear cover opening

    See alternative rebate

    section details

    Framedepth100mm

    Clear

    coveropening

    Rebate=clearc

    overopening+300mm

    Rebatedepth115mm

    Rebate

    Padlock boxCable

    lock

    CC

    B B

    A

    A

    115

    mm

    Clear cover opening

    and chamber opening

    Section A Arebate

    Section B B rebate

    150mm

    115

    mm

    Clear cover opening

    and chamber opening

    180mm

    Solid barrier = Suffix /ST Chains = Suffix /C.

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    5/6

    Section C C rebate

    430mm

    115mm

    Clear coveropening

    and chamberopening

    42

    GUARDSMAN DOUBLE UNIT COVEREasy slide, pivoting access chamber cover and frame.Galvanised to BS EN ISO 1461

    Clear opening1830 1930 2030 2130 2230(mm)

    800 XG18380B/G XG19380B/G XG20380B/G XG21380B/G XG2238 0B/G

    9 00 XG1 83 90 B/ G XG1 93 90B /G XG2 03 90 B/ G XG 213 90 B/ G XG 22 390 B/ G

    1000 XG18 310B /G XG19310B/G XG20310B/G XG21310B /G XG22310B/G

    1100 XG18311B/G XG19311B /G XG20311B/G XG21311B/G XG22311B/G

    1200 XG18 312B /G XG19312B/G XG20312B/G XG21312B /G XG22312B/G

    1300 XG18313B /G XG19313B/G XG20313B/G XG21313B /G XG22313B/G

    1400 XG18 314B /G XG19314B/G XG20314B/G XG21314B /G XG22314B/G

    1500 XG18 315B /G XG19315B/G XG20315B/G XG21315 B/G XG22315B/G

    FACTA CLASS

    B

    SLOW-MOVINGWHEEL LOAD

    5T

    Clear cover opening

    Sectional elevation

    Plan on cover frame

    Section A A rebate

    Clear cover opening

    and chamber opening

    115mm

    150mm

    See alternative rebate section detail

    Padlock box

    Padlockbox

    Remote supportframe

    Overall clear cover opening

    Rebate = clear cover opening + 860mm

    Cable flap

    Rebate

    Rebate=clearcover

    Opening+300mm

    = =

    Stanchion socket and clearoverall cover opening

    Framedepth

    100mmRebatedepth115mm

    A

    A

    C

    CC

    C

    230mm

    Clearcoveropening

    Solid barrier = suffix /ST. Chains = Suffix /C.

    All features as per singleunit on page 40

    Removable centre beamto give full access tothe chamber

    PRODUCT CODE

  • 8/2/2019 Brick House Brochure Section 6 Deep Chamber

    6/6

    Brickhouse Lane, West Bromwich

    West Midlands B70 0DY

    Tel: 0121 521 4500 Fax: 0121 521 4551

    Email: [email protected]

    www.steelway.co.uk

    STEELWAY

    Brickhouse

    E X P E R T S I N S T E E L

    Steelway is a leading

    engineering and fabrication

    company that specialises in the

    manufacture of steel, aluminium

    and GRP products.

    Our dedicated workforce prides

    itself on its professionalism and

    the quality finish of the productsproduced. We strive to be

    experts in our field.KM36158 BS EN 124 LPS1175 (LEVEL 4)CERTIFICATE No.

    FS533713 BSENISO9001

    CERTIFICATE No.

    EMS533715 BSENISO14001