brandon j. pierquet the impact of microinverters in ... · the impact of microinverters in...

47
©2008-2010 Enphase Energy Productive. Reliable. Smart. Safe. The Impact of Microinverters in Photovoltaic Systems Brandon J. Pierquet

Upload: phungngoc

Post on 22-May-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

©2008-2010 Enphase Energy

Productive. Reliable. Smart. Safe.

The Impact of Microinverters in Photovoltaic Systems

Brandon J. Pierquet

©2008-2010 Enphase Energy

Overview

Energy and PV Introduction

PV Module Characteristics

Understanding Installations

Inverter Hardware Design

Advanced Grid Controls

©2008-2010 Enphase Energy

Enphase installations

3

>20,000 North American installations in 30 months

©2008-2010 Enphase Energy 4

Energy and PV

©2008-2010 Enphase Energy

PV Introduction

©2008-2010 Enphase Energy

Photovoltaic Module Costs

http://solar.gwu.edu/

©2008-2010 Enphase Energy 7

Photovoltaic Source

PV module (not panel)– Translates light into electricity– Series connected cells

Multiple types of cells– Crystalline Silicon (poly, mono)– Multi-juntion– CdTe, CdInGaS, GaAs

Environmental Dependency– Temperature– Soiling– Age/Optical degradation

Efficiency from 12-20%

©2008-2010 Enphase Energy 8

PV module I/V curve

0 5 10 15 20 25 30 35 40

-50

0

50

100

150

200

250

300

Power vs VoltageIrradiance 1000W/m2 Irradiance 200W/m2

V

P

0 5 10 15 20 25 30 35 40

-2

0

2

4

6

8

10

PV characteristicsIrradiance 1000W/m2 Irradiance 200W/m2

V

I

Changes in irradiance modify the IV characteristic

Superposition of a string can lead to suboptimal curves, local maxima

©2008-2010 Enphase Energy 9

Inverters and Installations

©2008-2010 Enphase Energy

“Typical” Considerations

System Cost

Single centralized inverter Decentralized module-level inverters Hybrid approach – dc-dc optimizers

Residential – Primarily Rooftop Commercial – Rooftop and carpark Ground-mount Utility

©2008-2010 Enphase Energy 11

Total Solar Installation Cost (%)

Source: Enphase Energy estimates

Microinverters are only 10% of the total system cost, yet affect BoS and labor costs more than any other component.

The Other 50% of Solar Costs

©2008-2010 Enphase Energy 12

Central String Inverter

©2008-2010 Enphase Energy

Central dc-dc Optimizer System

©2008-2010 Enphase Energy 14

Microinverter System

©2008-2010 Enphase Energy 15

Traditional Centralized/Hybrid Inverter

DCDisconnect

DCCombiner Box

ElectricalMeter

ACDisconnect

CentralizedInverter

Modules

©2008-2010 Enphase Energy 16

Traditional Microinverter

ElectricalMeter

ACDisconnect

Modules

©2008-2010 Enphase Energy

Advancing Performance

17

Modules are controlled independently to maximize energy harvest

Per-module

Power Conversion

Traditional Inverter Microinverter

50% 100% 100% 100% 50%50% 50% 50% 50%

©2008-2010 Enphase Energy

Increased Energy Harvest

18

Greater energy production means a better return on investment

Productive

©2008-2010 Enphase Energy 19

System Availability Model

Enphase Microinverter System

Central Architecture

kW

kW

EnphaseSystemAvailability

>99.8%

©2008-2010 Enphase Energy

Westinghouse Solar Reliability Data

20

©2008-2010 Enphase Energy 2121

No inherent detection of wire faults

§ Disconnects may not interrupt fault path

§ System cannot de-energize during daytime

Standard Inverter Dangers

DC Arcs are Difficult to Suppress

©2008-2010 Enphase Energy 2222

NEC 2011 has changes that mandate detection of – and preventative measures for – series DC arc faults in systems where the DC voltage exceeds 80VDC

690.11 Arc-Fault Circuit Protection (Direct Current)

Photovoltaic systems with dc source circuits, dc output circuits, or both, on or penetrating a building operating at a PV system maximum system voltage of 80 volts or greater, shall be protected by a listed (dc) arc-fault circuit interrupter, PV type, or other system components listed to provide equivalent protection.

©2008-2010 Enphase Energy 23

Inverter Design Challenges

©2008-2010 Enphase Energy

Inverter Design Challenges

Single-phase Energy Storage Efficiency Reliability and Robustness Wide operating ranges

©2008-2010 Enphase Energy 25

Single-Phase Power Conversion Basics

Inherent input/output power-flow mismatch

Bulk energy storage required at 120Hz

0 2 4 6 8 10 12 14 160

50

100

150

200

250

300

350

400

450

DC powerAC power

©2008-2010 Enphase Energy

100.075.050.030.020.010.080

82

84

86

88

90

92

94

96

98 Microinverter CEC Test Data

Power Level (%)

Inverter Efficiency

(%)

26

Comp #2

Enphase

Comp #1

Testing using the CEC or EN 50530 definitions

©2008-2010 Enphase Energy 27

Light Load Efficiency

STORINGBURSTING BURSTING BURSTINGSTORING

Burst Mode: High efficiency at low irradiance

©2008-2010 Enphase Energy 28

Grid Standards / Compliance

Safety: NEC UL 1741

Interconnection: IEEE 1547 FERC 661

EMI: CFR 47 Part 15

Surge testing: ANSI C62.41

Typical US Grid, 60Hz:

Residential: 120V/240V

Commercial: 120V/208V, 3 phase

Industrial LV: 277/480V, 3 phase

Typical Euro Grid, 50Hz:

Residential: 230V, single phase

Commercial/Industrial LV: 230V/400V 3 phase

©2008-2010 Enphase Energy

0 5 10 15 20 25 30

-150

-100

-50

0

50

100

150

0 5 10 15 20 25

-250-200-150-100-50

050

100150200250

Line 1 VoltageLine 2 voltage

AC Grid Realities

It's nasty:

Voltage surges of >1000 V from indirect lightning strikes

Tap changes, misplaced zero crossings, dc offset

Distortion, double zero crossings

Surviving it everyday and in all cases is very, very difficult

©2008-2010 Enphase Energy 30

Design Challenges

AC Side Functions Grid synchronization Voltage and Frequency

(out of range thresholds) Anti Islanding (AI) checks

DC Side Functions: Maximum peak power tracking

(speed and accuracy are important)

DC voltage and current reporting Arc-fault detection

From a dc-dc perspective: Wide input voltage range: 20-40 Vdc Wide output voltage range: 0-340Vdc (+/-) Wide power range: 0-200 W Large energy storage requirement Additional monitoring functions:

©2008-2010 Enphase Energy 31

Some Conversion Topologies

©2008-2010 Enphase Energy 32

Some Conversion Topologies

P. Krein and R. Balog

©2008-2010 Enphase Energy

Some Conversion Topologies

C. Bush and B. Wang

©2008-2010 Enphase Energy

Some Conversion Topologies

B. Pierquet, D. Perreault

©2008-2010 Enphase Energy 35

One Power Conversion Topology

©2008-2010 Enphase Energy 36

Inside the box…

©2008-2010 Enphase Energy 37

Review of Advantages

Productive

Harvests more energy

Reliable

No single point of failure, high reliability electronics

Smart

Allows for full system monitoring and analysis

No string calculation, regular AC wiring

Lowers installation time

Safe

No high voltage DC: DC faults cannot lead to fires

No lethal power source present when AC is shutdown

©2008-2010 Enphase Energy 38

Challenges

Very difficult product to get right

– Efficiency – Cost– Reliability – Lifetime– Robustness – Ease of use– Compliance to standards– Communication– Packaging – etc.

©2008-2010 Enphase Energy 39

Advanced Grid Controls(brief)

©2008-2010 Enphase Energy

Advanced Grid Controls

New Islanding behavior VAR injection Power slew based on frequency / voltage Spinning reserve emulation / Transient compensation All bring stability and jurisdiction issues. Under discussion and very controlled trials

x x' x''

Voltage

Current

Frequency

Phase

©2008-2010 Enphase Energy 41

Conclusion

©2008-2010 Enphase Energy

Some Example

Installation Photos

©2008-2010 Enphase Energy

Roof-mount in Hawaii

©2008-2010 Enphase Energy

Tracker Mount (Concentrated PV), Colorado

©2008-2010 Enphase Energy

Commercial Rooftop, Colorado

©2008-2010 Enphase Energy

Residential “Ground mount”

©2008-2010 Enphase Energy

Energy Production

Past Month: 151kWh, Lifetime: 1.78MWh (Since 7/15/11), Peak: 34kWh/day