booster alignment & magnet moves kiyomi seiya. aperture scan b75 : aperture scan program with...

17
Booster Alignment & Magnet Moves Kiyomi Seiya

Upload: bartholomew-benson

Post on 17-Jan-2016

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Booster Alignment & Magnet Moves

Kiyomi Seiya

Page 2: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Aperture scanB75 : Aperture scan program with new corrector

Kent Triplet, Alex WallerBPM data from B40 to B:HPXXX, B:VPXXX

Sharon LackeyData taking and offline analysis

Dean Still, Kiyomi Seiya

Analysis of Alignment dataData in August, 2009

B. OshinowAnalysis

Jim Lackey, Kiyomi Seiya

Lattice calculationMAD input

Jim Lackey, Kiyomi SeiyaB104 Booster model –MAD with alignment error

Bill Marsh

Page 3: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Aperture scan @ injection : B75with new correctors

B:CHGA(@inj.)/B:TCHGA(before Booster)

5BUMP3BUMP

Scale factorcorrector vs BPM

B:CHGB(@ext.)/B:TCHGA(before Booster)

Page 4: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Re-calibration corrector current - BPM

Corrector current and BPM data were taken by ACL script.Calculated scale factor.

H & V BPM data from B40 @ 2.33msec (8turns ave.)Corrector current

Page 5: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

B:40 position offset from 5 years ago

Page 6: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Offline analysis: B75 + BPM

before correction

afterScale factor change

after BPM offsetcorrection

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70-20

-15

-10

-5

0

5

10

15

20

Ver

(mm

)

Hor (mm)

0.000

12.82

25.64

38.46

51.28

64.10

76.92

89.74

SCAN_AT_LONG_14

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70-20

-15

-10

-5

0

5

10

15

20

Ver

(mm

)

Hor (mm)

recalc for bpm corrections scan_at_long_14

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70-20

-15

-10

-5

0

5

10

15

20

Ver

(mm

)

Hor (mm)

recalc for bpm correction v2 scan_at_long_14

Long 14 data showing orignal, bpm correctedand bpm corrected with B40 offset removed

hor offset removed =.7mmver offset removed = -1.69mm

Page 7: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Aperture @ L14 – L23

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_14

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_15

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

0.000

12.82

25.64

38.46

51.28

64.10

76.92

89.74

recalc for bpm correction scan_at_long_16

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_17

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_18

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_20

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm corrections scan_at_long_21

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_22

chg0

-70 -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70

-20

-15

-10

-5

0

5

10

15

20

Ve

r (m

m)

Hor (mm)

recalc for bpm correction scan_at_long_23

CHG0

Long-14

Long-17

Long-21 Long-22

Long-18

Long-15

Long-23

Long-20

Long-16

Page 8: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

14 16 18 20 22 24

-20

-10

0

10

20

30

40

xce

nte

r (m

m)

period

xcenter xupper xlower xaper

Recalc for bpm corrections & removal B40 offsetHorizontal LONG locations (Cut on 90%)

chg0

Horizontal Aperture @ L14 – L23

center

lower

upper

total

Page 9: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Vertical Aperture @ L14 – L23

14 16 18 20 22 24-15

-10

-5

0

5

10

15

20

25

30

yce

nte

r (m

m)

period

ycenter yupper ylower yaper

recalc for bpm correction & removal B40 offsetVertical LONG locations (Cut on 90%)

chg0

center

lower

upper

total

Page 10: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Data in August, 2009 (O’Sheg )F&D magnet * 48RF * 19New corrector *48

As found lattice(x,y,z) and no reference position for each component.

Analysis of Alignment data

Page 11: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

r_F=75.508566

r_D=75.434828

r_long=75.347261r_short=75.522538

(X,Y,Z) @center

A

BC

D

z

x

y

Ideal positions from design report

F D RF

Corrector+

BPM

Page 12: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

75.43

75.435

75.44

75.445

75.45

0 8 16 24 32 40 48

c10=sqrt((c3-30396.8758)^2+(c4-30306.5297)^2)

rad

ius[

m]

magnet #

Average = 75.4365 [m]std=0.0024

D-magnet @ center

r_F(design)=75.508566m+0.053inch

r_D(design)=75.434828m-0.040inch

Radial positions for F & D magnets

need reference position for each component

75.49

75.495

75.5

75.505

75.51

0 8 16 24 32 40 48

c10=sqrt((c3-30396.87640)^2+(c4-30306.5296)^2)

rad

ius

[m]

magnet #

Average = 75.5012 [m]std = 0.0022

F-magnet @ center

Page 13: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

221.428

221.429

221.43

221.431

221.432

221.433

221.434

221.435

221.436

0 5 10 15 20 25

D-UF-UF-DD-D

he

igh

t[m

]

cell #

Vertical error on F & D magnets

1[mm]

Page 14: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

L5 L10 L15 L20 ---5

0

5

10

15

20

25

30ve

rt c

en

ter

(mm

)

Booster V Location (vert long)

vert center (mm) Total Aper (mm) D_L (m) F_L (m)

Vertical aligment Data 2003 & Vertical Long Aperture Data 10-2001

221.416

221.418

221.420

221.422

221.424

221.426

221.428

221.430

221.432

221.434

221.436

221.438

221.440

221.442

221.444

221.446

221.448

221.450

D_

L (

m)

Vertical error on BPM

Center of the aperture

BPM Alignment error-short

aperture

BPM Alignment error-long

Page 15: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

sa drift 0.11CPS23 correctorsb drift 0.19

fmagu24FMAGU24 2.889612

miniS drift 0.5

dmagu24DMAGU24 2.889612

L24a drift 0.21RF drift 2.35L24b drift 0.12RF drift 2.35L24c drift 0.25HP24L drift 0.095VP24L drift 0.095L24d drift 0.045CPL24 correctorL24e drift 0.185

dmagd24DMAGD24 2.889612

miniS drift 0.5

fmagd24FMAGD24 2.889612

sc drift 0.6

Modified physical cell length = 19.7605 [m] for all 24 periods from original MAD.

Removed non existing components and replaced with drift with MAD.

Changed scale factor for the quad and skew quad on the new correctors from kquad= 0.02178 to 0.0025 and from ksquad = 0.00889 to 0.004.

The input file is in CVS lattice depository

Lattice calculation with MAD

Page 16: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Review each magnet current on the input file.ORBMP, DogLegs, corrector…

Add alignment error to the input file.

Add alignment error table to B104.

B104 BOOSTER lattice with alignment error

Page 17: Booster Alignment & Magnet Moves Kiyomi Seiya. Aperture scan B75 : Aperture scan program with new corrector Kent Triplet, Alex Waller BPM data from B40

Future plansFinish aperture scan. (50% left)

Make all tools to be available for operation.B75 Aperture scan (analysis with corrections.)Make references on alignment data sheet for

easier data gathering. B104 MAD (modify the input file and add alignment

table)

Ask for one week study time and move magnet at one location before shutdown.

Based on the results from alignment and aperture scan

Predict move, Move, Verify the move.