Page 1: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Infrastructure Measuring point configurations June 2019

Page 2: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 2 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

Boomerang 3.0 - principal block schematic

Measuring Points Various configurations on each measuring point are possible depending on data measured or logged, e.g. temperature, humidity or values from other sensors. Please see above some of the most common combinations. The following pages will give more examples of how to configure a Boomerang system.

Boomerang-in-the-cloud Boomerang 3.0 is a cloud service for continuous monitoring and log in laboratory environments. Numerous possibilities for connecting the log of your equipment to Internet, provides great flexibility to integrate monitoring and log all over the world.

Page 3: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 3 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S1001 Boomerang-in-the-cloud Licenses

All licenses required to run the webbased Boomerang 3.0 monitoring and log system.

1 BCLOUD 3.0 Boomerang 3.0 license for one (1) system

# MP001 License per measuring point, unlimited number of measuring points possible.

1 BCLOUDE-TEXT Web-service text messaging (SMS alarms/alerts) Option

Option 1 XB040 Licens for 4G-Boomerang Router, connects the local measuring points via the mobile network.

S1002 Installation and training

Boomerang equipment has to be installed on-site in laboratories.

# I020 Preparation/configuration/installation (days)

# I080 Travel cost (train/flights/ferries/etc..)

# I082 Hotel/accomodation costs

# I070 Mileage, car cost (kilometers)

Training

Page 4: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 4 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3001 Single Standard Temperature Measuring point (Memory)

Battery driven WiFi node for analog temperature sensors RTD, type Pt100. Memory buffer 3072 logs. Typical applications: Refrigerators, Freezers, Heated cabinets etc..

1 NWIB001 Wifi node with battery and memory backup

1 FT050/030 Pt100 sensor –90°C to +200°C, ±0.5°C accuracy, 60mm probe, 3 meter cable (other lengths available)

1 SN023 WIBNode 110/230 VAC Net adapter Power supply (EU) Option

Option 1 DBU001 Temperature Stabilizator, Aluminum block 140g.

DBU001

S3002 Dual Standard Temperature Measuring points (Memory)

Battery driven WiFi node for analog temperature sensors RTD, type Pt100. Memory buffer 3072 logs. Typical applications: Refrigerators, Freezers, Heated cabinets etc. located side-by-side

1 NWIB002 Wifi node with battery and memory backup, can connect two sensors

2 FT050/030 Pt100 sensor –90°C to +200°C, ±0.5°C accuracy, 3 meter cable (other lengths available)

1 SN023 WIBNode 110/230 VAC Net adapter Power supply (EU) Option

Option 1 DBU001 Temperature Stabilizator, Aluminum block 140g.

Page 5: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 5 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3004 Single Cryo Temperature Measuring point (Memory)

Battery driven WiFi node for analog temperature sensors RTD, type Pt100. Memory buffer 3072 logs. Typical applications: Liquid Nitrogen Dewars / LN2-tanks, Cryo-storage, Ovens and ot-her high temperature apps.

1 NWIB001 Wifi node with battery and memory backup

1 FT051/010 Pt100 sensor, –200°C to +200°C, ±0.5°C accuracy, 600mm probe, 3 meter cable (other lengths available)

1 DR019 Elastic mounting strap, belt for dewars/tanks

Option 1 SN023 WIBNode 110/230 VAC Net adapter Power supply (EU)

S3005 Dual Flexcable Temperature Measuring points (Memory) for Benchtop Incubators

Battery driven WiFi node for analog temperature sensors RTD, type Pt100. Memory buffer 3072 logs. Typical applications: Benchtop Incubators, Surface monitoring, Small chamber monito-ring. IVF-clinics

1 NWIB002 Wifi node with battery and memory backup

1-2 FT052/030 Pt100 sensor, –90°C to +200°C, ±0.5°C accuracy, 15mm probe, 80cm flexcable (total 3m cable)

1-2 DR020 Clamp device Option

Option 1 SN023 110/230 VAC Net adapter Power supply

Page 6: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 6 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S2001 Multi input Standard Temperature Measuring points

BoomBridge One, LAN-based multi-sensor node for digital temperature sensors. Typical applications: Refrigerators. Freezers

1 XBB006 LAN-based node, BBO, for up to 24 digital temperature sen-sors FT04x. 110/230VAC power adapter.

# FT040/030 Digital temperature sensor –10°C to +85°C, ±0.5°C accuracy (down to -20°C, ±1°C), 6×60mm probe, 3 meter cable (other lengths available)

Option # RD022 Splitter for three (3) FT04x sensors, cascadable

S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C)

BoomBridge One, LAN-based multi-sensor node for digital sensors. Typical applications: Laboratories, Biobanks, Blood banks et.. Ultra low freezers, Cryofreezers etc.

1 XBB006 LAN-based node, BBO, for up to 24 digital sensors . 110/230VAC power adapter.

# XBT006 Onewire digital interface to BBO, for one (1) Pt100 sensor

# FT012/050 Pt100 sensor –90°C to +200°C, ±0.5°C accuracy, 60mm probe, 5 meter cable (other lengths available)

Option # RD022 Splitter for three (3) Digital interfaces/sensors, cascadable

Page 7: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 7 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3006 Dual Analog input Measuring points (Memory) for Differential Pressure

Battery driven WiFi node for analog input signals 4-20mA, 24V supply. Memory buffer 3072 logs. Typical applications: Cleanrooms, sterile labs

1 NWIB004 Wifi node with battery and memory backup, two analog inputs 4-20mA

1 RD025 Analog WIB adapter, 12-24V to analog input signals

** 1-2 XBV003 Micatrone MF-PD Low pressure transmitter ±50 PA

1 SN025 110/230 VAC Net adapter Power supply 24VDC

**Option 1-2 XB031 MF-PD Alarm module

Option 1-2 XB021 Strobe beacon (alarm indication)

Option 1 DBU050 Miscellaneous tubes, connectors, valves etc.

S2003 Multi input Analog Measuring points for Differential Pressure

BoomBridge One, LAN-based multi-sensor node for analog inputs (4-20mA) . Typical applications: Cleanrooms, Sterile labs

1 XBB012 LAN-based node, BBO, for up to 8 analog inputs plus digital temperature sensors FT04x. 110/230VAC power adapter.

** 1-8 XBV003 Micatrone MF-PD Low pressure transmitter ±50 PA

**Option 1-8 XB031 MF-PD Alarm module

Option 1-8 XB021 Strobe beacon (alarm indication)

Option 1 DBU050 Miscellaneous tubes, connectors, valves etc.

DBU050

** 3rd party supplier, can be serviced (sourced) by local sales partner

Page 8: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 8 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3007 Dual Analog input Measuring points (Memory) for Humidity and Temperature

Battery driven WiFi node for analog input signals 4-20mA, 24V supply. Memory buffer 3072 logs. Typical applications: Box Incubators, Glove boxes, Stability chambers etc.

1 NWIB004 Wifi node with battery and memory backup, two analog inputs 4-20mA

1 SN025 110/230 VAC Net adapter Power supply 24VDC

1 RD025 Analog WIB adapter, 12-24V to analog input signals

1 FH013 RTH sensor, Vaisala HMT120, 3m cable, ±1.5% accuracy (0-90% RH)

S3008 Dual Analog input Measuring points (Memory) for Humidity and Temperature in Cleanrooms

Battery driven WiFi node for analog input signals 4-20mA, 24V supply. Memory buffer 3072 logs. Typical applications: Cleanrooms

1 NWIB004 Wifi node with battery and memory backup, two analog inputs 4-20mA

1 SN025 110/230 VAC Net adapter Power supply 24VDC

1 RD025 Analog WIB adapter, 12-24V to analog input signals

1 FH011 RTH sensor with display, Vaisala HMT120, 3m cable, ±1.5% accuracy (0-90% RH)

Page 9: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 9 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S2004 Multi input Digital Measuring points for Combined Temperature and Humidity (Room RTH)

BoomBridge One, LAN-based multi-sensor node for digital RTH sensors. Typical applications: Laboratories, cleanroms etc for Ambient/Room RTH

1 XBB006 LAN-based node, BBO, for up to 24 digital RTH sensors FH010. 110/230VAC power adapter.

# FH010 Digital RTH sensor, wall mounted.

Option # RD022 Splitter for three (3) digital sensors, cascadable

Page 10: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 10 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3009 Dual Analog input Measuring points (Memory) for Box Incubators (CO2 )

Battery driven WiFi node for analog input signals 4-20mA, 24V supply. Memory buffer 3072 logs. Typical applications: CO2 monitoring and log in different types of box incubators in IVF labs

1 NWIB004 Wifi node with battery and memory backup, two analog inputs 4-20mA

1 RD025 Analog WIB adapter, 12-24V to analog input signals

1 SN025 110/230 VAC Net adapter Power supply 24VDC

** 1-2 FC014 CO2 sensor, Vaisala GMP251, 0-20%, calibrated at +37°C

Option 1-2 RD021 FC014/GMP251 flatcable adapter, for incubators without ac-cess port

RD021

FC014

S2005 Multi input Analog and Digital Measuring points for Box Incubators (CO2 and Temperature)

BoomBridge One, LAN-based multi-sensor node for digital temperature sensors and for analog inputs 4-20mA Typical applications: CO2 andTemperature monitoring and log in different types of box incubators in IVF labs

1 XBB012 LAN-based node, BBO, for digital temperature sensors FT04x and analog inputs 4-20mA. 110/230VAC power adapter.

1-3 FT040/030 Digital temperature sensor –10°C to +85°C, ±0.5°C accuracy (down to -20°C, ±1°C), 6×60mm probe, 3 meter cable (other lengths available)

** 1-3 FC014 CO2 sensor, Vaisala GMP251, 0-20%, calibrated at +37°C

Option 1-3 RD021 FC014/GMP251 flatcable adapter, for incubators without ac-cess port

** 3rd party supplier, can be serviced (sourced) by local sales partner

Page 11: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 11 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S3010 Dual Analog input Measuring points (Memory) for Oxygen in Cryostorage rooms

Battery driven WiFi node for analog input signals 4-20mA, 24V supply. Memory buffer 3072 logs. Typical applications: Cryo storage rooms

1 NWIB004 Wifi node with battery and memory backup, two analog inputs 4-20mA

1 SN025 110/230 VAC Net adapter Power supply 24VDC

1 RD025 Analog WIB adapter, 12-24V to analog input signals

** 1 FC019 Analox O2NE+ Oxygen (O2) depletion monitor Incl. alarm unit (audio / visual)

** 3rd party supplier, can be serviced (sourced) by local sales partner

Page 12: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 12 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S2006 Multi input Analog and Digital Measuring points for Particle Counters

BoomBridge One, LAN-based multi-sensor node for digital temperature sensors and for analog inputs 4-20mA Typical applications: Cleanrooms and Sterile labs

1 XBB012 LAN-based node, BBO, for digital temperature sensors FT04x and analog inputs 4-20mA. 110/230VAC power adapter.

** 1-2 FS001 Particle counter MO6015 + inst.kit (no pump) Configurable for three particle sizes inputs

** 1 FS002 Vacuum pump 230 VAC

** 1 DBU051 Miscellaneous tubes, connectors, valves, power supplies etc.

FS002

FS001

** 3rd party supplier, can be serviced (sourced) by local sales partner

Page 13: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 13 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

S1003 On-site Calibration services

Qualified calibration of your measurement equipment leads to less uncertainty in your measurements. Your measurement accuracy will be assured by calibration protocol and certificates for full traceability.

1 I041 Calibration start cost

# I040 Calibration cost per Temperature

# I042 Calibration cost per Humidity

Option # I080 Travel costs and accomodation

S1004 IQ / OQ package

ICU Scandinavia performs qualification services for Boomerang customers that wants to validate their operations.

1 I043 Installation Qualification

2 I044 Operational Qualification

Option # I080 Travel costs and accomodation

Page 14: Boomerang measuring points - ICU Scandinavia · S2002 Multi input Analog Temperature Measuring points for Low Temperatures (-80°C) BoomBridge One, LAN-based multi-sensor node for

Brief Technical Description: 14 www.icuscandinavia.com Boomerang3 Infrastructure - Measuring point configurations

Measuring points - principal block schematic and connection

Measuring points - Sensor selection and alternatives Boomerang measuring points can use different types of sensors/probes, depending on certain characteristics of the equipment where the sensor will be installed, or depending on the range to be measured, or depending on which unit of measure-ment you are looking for.