SEMINAR PRESENTATION ON
BOILERS
Aditya AggarwalMechanical EngineeringSection-1, Year – IVUniv. No. 10430104031
Seminar Guide:Er Ashwani Kumar
Faculty – Mechanical Engineering
![Page 2: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/2.jpg)
“Boiler is an apparatus use to produce steam.”
It is a device in which thermal energy released by combustion of fuel is used to make steam at the desired temperature and pressure.
What is Boiler?
![Page 3: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/3.jpg)
Need Of SteamThe steam produced is used for:1. Producing mechanical work by expanding it
in steam engine or steam turbine.2. Heating the residential and industrial
buildings3. Performing certain processes in the sugar
mills, chemical and textile industries.
![Page 4: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/4.jpg)
Boiler Properties• Safety The boiler should be safe under operating
conditions.• Accessibility
The various parts of the boiler should be accessible for repair and maintenance.
• Capacity Should be capable of supplying steam
according to the requirements
![Page 5: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/5.jpg)
Efficiency Should be able to absorb a maximum amount of
heat produced due to burning of fuel in the furnace.
It should be simple in construction .
Its initial cost and maintenance cost should be low.
The boiler should have no joints exposed to flames.
Should be capable of quick starting and loading.
![Page 6: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/6.jpg)
Classification Of Boilers
Boilers
Acc to Flow
Water Tube
Fire Tube
Acc to position of furnace
Externally Fired
Internally Fired
Acc to position
Vertical
Horizontal
Inclined
Acc to Application
Stationary
Mobile
Acc to circulation
Natural
Forced
Acc to Pressure
Low Pressure
Medium Pressure
High Pressure
![Page 7: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/7.jpg)
Boilers
Acc to Flow
Water Tube
Fire Tube
Acc to position of
furnace
Externally Fired
Internally Fired
Acc to principle axis
Vertical
Horizontal
Inclined
Acc to Application
Stationary
Mobile
Acc to circulation
Natural
Forced
Acc to Pressure
Low Pressure
Medium Pressure
High Pressure
![Page 8: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/8.jpg)
According to what flows in the TUBE
1. Water tube.2. Fire tube.
![Page 9: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/9.jpg)
Fire Tube Boiler
Furnace Smokestack
Boiler
![Page 10: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/10.jpg)
Water Tube Boiler
![Page 11: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/11.jpg)
MERITS OF WATER TUBE BOILERS OVER FIRE TUBE BOILERS
1. Generation of steam is much quicker due to small ratio of water content to steam content. This also helps in reaching the steaming temperature in short time.
2. Its evaporative capacity is considerably larger and the steam pressure range is also high-200 bar.
3. Heating surfaces are more effective as the hot gases travel at right angles to the direction of water flow.
![Page 12: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/12.jpg)
DEMERITS
1. It is less suitable for impure and sedimentary water, as a small deposit of scale may cause the overheating and bursting of tube. Therefore, use of pure feed water is essential.
2. They require careful attention. The maintenance costs are higher.
3. Failure in feed water supply even for short period is liable to make the boiler over-heated.
![Page 13: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/13.jpg)
Advantages of fire tube boilers
1. Low cost2. Fluctuations of steam demand can be
met easily3. It is compact in size.
![Page 14: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/14.jpg)
Water tube boilers are classified as
Water Tube
Boilers
Horizontal Straight Tube Boilers
Longitudinal Drum
Cross Drum
Bent Tube Boilers
Two Drum
Three Drum
Low Head Drum
Four Drum
Cyclone Drum Boilers
![Page 15: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/15.jpg)
In Detail
1. Cochran Boiler2. Lancashire Boiler3. Locomotive boiler4. Babcock Wilcox Boiler
![Page 16: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/16.jpg)
COCHRAN BOILER
![Page 17: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/17.jpg)
WORKING
![Page 18: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/18.jpg)
Features
1. It is very compact and requires minimum floor area
2. Any type of fuel can be used with this boiler
3. Well suited for small capacity requirements4. It gives about 70% thermal efficiency with
coal firing and about 75% with oil firing
![Page 19: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/19.jpg)
Main parts ……1. Pressure Gauge. This indicates the pressure of the
steam in the boiler.2. Water Level Indicator. This indicates the water
level in the boiler .3. Safety Valve. The function of the safety valve is to
prevent the increase of steam pressure in the holler above its design pressure.
4. Fusible Plug. If the water level in the boiler falls below a predetermined level, the boiler shell and tubes will be overheated.
![Page 20: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/20.jpg)
5. Blow-off Cock. The water supplied to the boiler always contains impurities like mud, sand and, salt Due to heating, these are deposited at the bottom of the boiler, they have to be removed using blow off cock.
6. Steam Stop Valve. It regulates the flow of steam supply outside. The steam from the boiler first enters into an ant-priming pipe where most of the water particles associated with steam are removed
7. Feed Check Valve. The high pressure feed water is supplied to the boiler through this valve. This valve opens towards the boiler only and feeds the water to the boiler.
![Page 21: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/21.jpg)
LANCASHIRE
BOILER
![Page 22: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/22.jpg)
About It is stationary fire tube, internally fired,
horizontal, natural circulation boiler. This is a widely used boiler because of its good steaming quality and its ability to burn coal of inferior quality. These boilers have a cylindrical shell 2 m in diameters and its length varies from 8 m to 10 m. It has two large internal flue tubes having diameter between 80 cm to 100 cm in which the grate is situated. This boiler is set in brickwork forming external flue so that the external part of the shell forms part of the heating surface.
![Page 23: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/23.jpg)
Working
![Page 24: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/24.jpg)
Advantages1. The feed pipe projecting into the boiler is
perforated to ensure uniform water distribution.2. Its heating surface area per unit volume at the boiler
is considerably large.3. Its maintenance is easy.4. It is suitable where a large reserve of hot water is
needed. This boiler due to the large reserve capacity can easily meet load fluctuations.
5. Super-heater and economizer can be easily incorporated into the system, therefore; overall efficiency of the boiler can be considerably increased (80-85%).
![Page 25: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/25.jpg)
LOCOMOTIVEBOILER
![Page 26: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/26.jpg)
About Locomotive boiler is a horizontal fire tube
type mobile boiler. The main requirement of this boiler is that it should produce steam at a very high rate. Therefore, this boiler requires a large amount of heating surface and large grate area to burn coal at a rapid rate. In order to provide the large heating surface area, a large number of fire tubes are setup and heat transfer rate is increased by creating strong draught by means of steam jet.
![Page 27: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/27.jpg)
WORKING
![Page 28: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/28.jpg)
Advantages1. Large rate of steam generation per square
metre of heating surface. To some extent this is due to the vibration caused by the motion.
2. It is free from brickwork, special foundation and chimney. This reduces the cost of installation.
3. It is very compact.
The pressure of the steam is limited to about 20 bar.
![Page 29: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/29.jpg)
BABCOCKWILCOX BOILER
![Page 30: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/30.jpg)
Working
![Page 31: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/31.jpg)
Features1.The evaporative capacity of this boilers is high
compared with other boilers (20,000 to 40,000kg/hr). The operating pressure lies between 11.5 to 17.5 bar.
2.The draught loss is minimum compared with other boilers.
3. The defective tubes can be replaced easily.4.The entire boiler rests over an iron structure,
independent of brick work, so that the boiler may expand or contract freely. The brick walls which form the surroundings of the boiler are only to enclose the furnace and the hot gases.
![Page 32: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/32.jpg)
Boiler Performance
1. Evaporative capacity can be expressed in terms of:
a) kg of steam/hr
b) kg of hour/hr/m2 of heating surface
c) kg of steam/kg of fuel fired
![Page 33: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/33.jpg)
2. Equivalent Evaporation
Evaporative capacity expressed in terms of mass of water getting converted to steam doesn’t give a good comparison
me= ma(h-hf)/hfg
![Page 34: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/34.jpg)
3. Factor of evaporation
It is defined as the ratio of the heat received by 1 kg of water at the working conditions to that received by 1 kg of water evaporated from and at 1000C
Fe = (h –hf)/2257 KJ
![Page 35: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/35.jpg)
4. Boiler efficiency
Ratio of heat actually utilized in the generator to the heat supplied by the fuel.
Efficiency= ma(h-hf)/CWhere C is the calorific value
![Page 36: BOILER PPT.pptx](https://reader034.vdocuments.us/reader034/viewer/2022051415/55cf9b20550346d033a4d5fc/html5/thumbnails/36.jpg)
THANK YOU