bmd crossvent 3
DESCRIPTION
bmd Crossvent 3. Modes – Touch Screen. Adult to pediatric range Assist/Control – Volume Control Assist/Control – Pressure Control Sighs SIMV Pressure Support CPAP. Turn knobs for setting:. Maximum pressure PEEP Flow. LCD Touch Screen Select Mode then press MAIN menu. - PowerPoint PPT PresentationTRANSCRIPT
11
bmd Crossvent 3bmd Crossvent 3
22
Modes – Touch ScreenModes – Touch Screen
Adult to pediatric rangeAdult to pediatric range Assist/Control – Volume ControlAssist/Control – Volume Control Assist/Control – Pressure ControlAssist/Control – Pressure Control SighsSighs SIMVSIMV Pressure SupportPressure Support CPAPCPAP
33
Turn knobs for setting:Turn knobs for setting:
Maximum pressureMaximum pressure PEEPPEEP FlowFlow
44
LCD Touch ScreenLCD Touch ScreenSelect Mode then press MAIN menuSelect Mode then press MAIN menu Then press Then press
Rate & TV Rate & TV – adjust with adjust with
up/down up/down arrowsarrows
IT, ET & I:E IT, ET & I:E Ratio Ratio displayeddisplayed
Flow, PEEP Flow, PEEP & Max & Max Press limitPress limit– adjust with adjust with
dials dials
55
On the left sideOn the left side
ON/OFFExternal Power Supply
Alarm Reset
LED ChargingLight
Pneumotach/FlowSensor Input
Exhalation ValveConnector
Airway PressureConnector
Pt Circuit
O2 Sensor
66
bmd CrossVent 3bmd CrossVent 3
powered by a rechargeable NiMH powered by a rechargeable NiMH batterybattery– lasts 6 hourslasts 6 hours
BioMed 16vDC 3A charger/converter BioMed 16vDC 3A charger/converter recharges internal battery and allows recharges internal battery and allows for AC operationfor AC operation
LCD screen has LCD charging LCD screen has LCD charging indicator and visually large LOW indicator and visually large LOW BATTERY alarmBATTERY alarm
77
Flow Sensor at proximal Flow Sensor at proximal airwayairway
88
Flow SensorFlow Sensor
99
On the right sideOn the right side
Gas Supply Inlet (31 - 75 psig or 45 - 75 when using blender)
Gas EntrainmentON/OFF
Bleed Exhaust
1010
Gas EntrainmentGas Entrainment
When connected to 100% oxygen When connected to 100% oxygen source gas with the Gas Entrainment source gas with the Gas Entrainment ON, the oxygen concentration is ON, the oxygen concentration is diluted to 50%.diluted to 50%.
There will be some decrease in There will be some decrease in delivered flow rate with Entrainment delivered flow rate with Entrainment ON under high load conditionsON under high load conditions
1111
The rear panelThe rear panel
Maximum pressure relief valve (120 Maximum pressure relief valve (120 cm Hcm H22O)O)
Negative pressure relief valve – Negative pressure relief valve – opens at - 4 cm H2O with machine opens at - 4 cm H2O with machine shutdownshutdown
1212
SIMV settingsSIMV settings
1313
Press arrows to increase or Press arrows to increase or decrease Rate or Tidal Volumedecrease Rate or Tidal Volume
1414
Touch screen to highlight TV – Touch screen to highlight TV – Adjust with up/down arrowsAdjust with up/down arrows
1515
CPAP ModeCPAP Mode
1616
ALARMSALARMS
ALARM 1 ALARM 1 – Peak PressurePeak Pressure– Respiratory RateRespiratory Rate– Exhaled Tidal Volume (can be switched off)Exhaled Tidal Volume (can be switched off)– Exhaled Minute Volume (can be switched Exhaled Minute Volume (can be switched
off)off) ALARM 2ALARM 2
– PEEPPEEP– Mean Pressure (can be switched off)Mean Pressure (can be switched off)– Oxygen (can be switched off)Oxygen (can be switched off)
1717
To set Alarms Press ALARM To set Alarms Press ALARM 11
Press Press High or High or Low Low Limits to Limits to ChangeChange
Adjust Adjust with with up/down up/down arrowsarrows
1818
Repeat for ALARM 2 settingsRepeat for ALARM 2 settings
1919
33rdrd Level Alarms Level Alarms
Low Gas Supply Pressure
Low Battery
Ventilator Failure
2020
With Alarm Condition:With Alarm Condition:
the value for the exceeded limitflashes red
-1
2121
When power off, press and When power off, press and hold ALARM RESEThold ALARM RESET