bituminous membranes - ardex · bituminous membranes 3-10 shelterbit membranes 11-15 shelterbit...

60
Bituminous Membranes 3-10 Shelterbit Membranes 11-15 Shelterbit BRANZ Appraisal 16 Shelterbit Phoenix Star (Mineral) Colour Range 17-51 Shelterbit 17 Phoenix Star (Mineral) 21 Phoenix Star (Plain) 25 Vented Base Sheet 29 Fibre Backed Base Sheet 33 Fibrepol 120 Membrane 37 Fibrepol 180 Membrane 41 Garden Membrane 45 HD Bridge Membrane 49 Fibrepol SBS Membrane 53-55 Shelterbit Duo 57-58 Shelterbit Shingles 59-60 Shelter Primer

Upload: doanmien

Post on 30-Apr-2018

215 views

Category:

Documents


1 download

TRANSCRIPT

Bituminous Membranes

3-10 Shelterbit Membranes

11-15 Shelterbit BRANZ Appraisal

16 Shelterbit Phoenix Star (Mineral) Colour Range

17-51 Shelterbit 17 PhoenixStar(Mineral) 21 PhoenixStar(Plain) 25 VentedBaseSheet 29 FibreBackedBaseSheet 33 Fibrepol120Membrane 37 Fibrepol180Membrane 41 GardenMembrane 45 HDBridgeMembrane

49 FibrepolSBSMembrane

53-55 Shelterbit Duo

57-58 Shelterbit Shingles

59-60 Shelter Primer

ARDEX Shelterbit MembranesTorchAppliedMembranes

BRANZAppraisedE2/AS1AlternativeSolution

ThismanualconformstotheCodeofPracticefortheSelection,DesignandInstallationofTorch-onMembraneSystems.ThisCodeofPracticehasbeendevelopedandpreparedbythe12membercompaniesoftheMembraneGroup,RoofingAssociationofNewZealand(RANZ)andutilisesthecollectiveexperienceofTorch-onMembraneSuppliers,ContractorsandSpecifiersinNewZealand.ArdexNZLtdisoneofthemembercompaniesoftheMembraneGroup.

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

3

ThisrecommendationhasbeenpreparedforthegeneralinstallationofaShelterbitMembraneSystem.Eachprojectcanhaveitsownspecialconditionsandidiosyncrasiesthatmayrequirespecialconditionsand/orprocessesofinstallation.ConfirmationofthesuitabilityforthisrecommendationinrelationtoanyprojectshouldbesoughtfromtheArdexRepresentativepriortospecifying.TheapplicationofShelterbitmembranesshouldbecarriedoutbyanapprovedApplicatorofArdexwaterproofingmembranes.InstallationshallbestrictlyinaccordancewiththeManufacturer’srecommendations.AllmaterialsusedinconjunctionwiththeShelterbitSystemsmustbeapprovedbyArdex.

STORAGE AND HANDLING

Rollsofmembranedeliveredtothesitearetobestoredinacoveredareaorbecoveredwithaprotectivesheetuntilrequiredforinstallation.Rollsaretobestoredverticallytakingcaretopreventdamagetotheends.Rollsarenottobedroppedormishandled.

SURFACE PREPARATION

ConcreteSurfacestowhichtheShelterbitsystemsareinstalledmustbeproperlypreparedpriortoinstallation.Allsurfacesmustbeclean,dry,smooth,freeofsharpedges,fines,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.Sand/cementfilletsarerecommendedatallchangeindirectionofsubstrate(fromhorizontaltovertical).

SUBSTRATE SPECIFICATION (Plywood)

ToconformwithAcceptableSolutionE2/AS1plywoodshallbe:Aminimumof17mmcomplyingwithAS/NZS2269,atleastCDStructuralGradeplywoodwiththesandedCfaceupwards,andH3.2withWaterborneCCAtreatmentandkilndriedaftertreatment.SubstratesmustbedrywhenArdexWPM116(FibreBackedBaseSheet)isapplied.Theplywoodandthetimbersubstructureshallhaveamaximummoisturecontentof20%whenShelterbitisadhered.Plywoodpanelsshallbelaidwithstaggeredjoints(brickbond),theedgeofsheetsshallbesupportedwithdwangsorframing,unlessastructurallytestedtongue-in-grooveedgeprovidesequivalentsupport.ThemaximumrecommendedspaninE2/AS1is400mmineachdirection.Howeverspecificdesignmayallow17.5mmplywoodorgreatertobelaidon400mmpurlinswithnogsordwangsat600mmoreven1200mmcentres.Plywoodshallbelaidwiththefacegrainatrightanglestothesupports.A20mmtriangularfilletshallbeusedatthebaseofany90°upstand.

Externaledgesshallbechamferedwithaminimumradiusof5mm.Plywoodshallbefixedwith10gaugex50mmstainlesssteelcountersunkheadscrewsegHyltonParkerNo24639,with3mmgapsbetweenallsheets,at150mmcentresonedges,and200mminthebodyofthesheets.Alljointsintheplywoodandjunctionsofplywoodwithothermaterialsshallhave25mmpolyethylenereleasetapeappliedbeforeapplicationofArdexWPM116(FibreBackedBaseSheet).Closed-inconstructionspacesunderShelterbitroofsanddecksshallhaveadequateventilationtopreventtheaccumulationofmoistureunderShelterbit.Thereshouldbeaminimumgapof20mmbetweentheundersideofthesubstrateandanyinsulation.CommencementoflayingshallbetakenasacceptanceofthesubstratebytheapprovedApplicator.

PRIMING

PriortotheapplicationoftheShelterbitallpreparedsurfacesshallbeprimedwithShelterbitPrimeratarateof5-6m2perlitreandallowedtodry.Coverageofprimermayvarydependingonthedensityorporosityofthesubstrate.Primermaybeappliedbybrush,rollerorsprayequipment.Coveragemustbeuniform.NotethatprimingisnotrequiredfortheinstallationofArdexWPM116(FibreBackedBaseSheet)whenusedonPlywood.

MEMBRANE SYSTEM COMBINATION

Shelterbitcanbeusedinvariouscombinations,refertoShelterbitSystemRecommendationsinthissectionforyourindividualwaterproofingrequirement.

TESTING

Afterinstallation,itisrecommended,wherepossible,awatertestbecarriedoutfor24hours.

PROTECTION

Aprotectionlayershouldbeusedwhenbackfillingoratoppingisrequired,(Protectionboardordrainagecellforbackfillingorslipsheetfortopping).

SAFETY

Shelterbitisnotclassifiedasdangerousgoods.However,duringinstallation,exerciseextremecautionwhenworkingwithopenflame.Donotuseopenflamedirectlyonhighlycombustiblematerial.Followalllocalfirecodes.

ARDEX Shelterbit MembranesInstallation Specification

4

Spec. No. System

Systems for concrete or topping substrates:

Single Layer Non Exposed Systems

01 Onelayerof2.5-5.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

Two Layer Non Exposed Systems

02 FirstlayerofSBS2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.Secondlayerof2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

03 FirstlayerofSBS2.5-4.0mmsand/torchablefilmfinishedShelterbitTorch-onmembrane.SecondlayerofShelterbitSBSColdClimatemembrane.

04 FirstlayerPeelandStickbasesheet2.0mmtorchablefilmfinish.Secondlayerof2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

Three Layer Vented Non Exposed System

05 FirstlayerAPPShelterbitVentedBaseSheetnotcountedaswaterprooflayer.Secondlayerof2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.Thirdlayerof2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

Two Layer Exposed Systems

06 Firstlayerof2.5-4.0mmsand/torchablefilmfinishedAPPShelterbitTorch-onmembrane.Secondlayerof4.0mmorgreatermineralchipfinishedAPPShelterbitTorch-onmembrane.

Three Layer Vented Exposed Systems

07 FirstlayerAPPShelterbitVentedBaseSheetnotcountedaswaterprooflayer.Secondlayer2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.Thirdlayerof4.0mmorgreatermineralchipfinishedAPPShelterbitTorch-onmembrane.

Systems for Plywood substrates:

Two Layer Non Exposed Systems

08 FirstlayerofAPPShelterbitFibreBackedBaseSheetgluedinplace.Secondlayer2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

09 FirstlayerPeelandStickbasesheet2.0mmtorchablefilmfinish.Secondlayer2.5-4.0mmsand/torchablefilmfinishedAPP/SBSShelterbitTorch-onmembrane.

Two Layer Exposed Systems

010 FirstlayerofAPPShelterbitFibreBackedBaseSheetgluedinplace.Secondlayerof4.0mmorgreatermineralchipfinishedAPPShelterbitTorch-onmembrane.

011 FirstlayerPeelandStickbasesheet2.0mmtorchablefilmfinish.Secondlayerof4.0mmorgreatermineralchipfinishedAPPShelterbitTorch-onmembrane.

ARDEX Shelterbit MembranesSystem Recommendations

ShelterbitTorch-onwaterproofingmembranescanbeusedinawidevarietyofcombinationstosuittherequirementsofaspecificwaterproofingapplication.Thefollowingtableoutlinesmostoftheacceptablealternativesforarangeofcommonsituationsencountered.PleaseconsultwithyourArdexrepresentativetoselectthemostappropriatesolution.

5

ARDEX Shelterbit MembranesInstallation Details

Wall

2

2

2

3

3

3

1

SHEET LAYOUT

Application Details Two Waterproofing LayersStaggered Layout for Finish Membrane

TYPICAL TURN UP DETAILS -EXPOSED MEMBRANE

Sand Cement Fillet

3rd Layer Membrane Chip

2nd Layer Membrane1st Layer Vented Base Sheet

1 Primer2 2nd Layer3 3rd Layer

Half Sheet

TYPICAL TURN UP DETAILS -NON-EXPOSED MEMBRANE

Sand Cement Fillet

3rd Layer

2nd Layer

1st Layer

Sand Cement Fillet

2nd Layer

1st Layer

Sand Cement Fillet

Main Membrane Layer

Reinforcing Layer of Membrane

Reinforcing Layer of Membrane

Reinforcing Layer of Membrane

6

CAPPING DETAIL

EXPANSION JOINT

CONSTRUCTION JOINT

ALTERNATIVE EXPANSION JOINT

Capping Sealant

Bituminous Fibreboard

Sand Cement FilletBallast

SlipsheetInsulationMembranePrimer

Screed

Concrete

Shelterbit top layer fully bonded except over 250mm strip

250mm Shelterbit strip stuck to one side of the joint only

Concrete Slab

Shelterbit top layer fully bonded except over 300mm underflashing

300mm Shelterbit underflashing fully bonded each side of joint

Concrete Slab

Fire Resistant Product

Expansion Joint

Metal Capping

MembraneSand Cement Fillet

Concrete300mm Base Sheet

PRESSURE SEAL CAPPING DETAIL

Shelterbit Membrane

Fillet

Pressure Seal Flashing

TWO METHODS FOR FINISHING OVER A GUTTER

Planed plywood edgeShelterbit

Plywood

Galvanised Flashing screwed onto plywood

Framing

Gutter

Planed plywood edgeShelterbitPlywood

Galvanised Flashing

Fascia

Gutter

7

ARDEX Shelterbit MembranesInstallation Details

TYPICAL OUTLET DETAIL

ROOF EDGE - MECHANICALLY FIXED

Grate

Shelterbit Membrane Membrane

under flashing

ConcreteOutlet Insert

Mechanical Fixing

Metal Capping

Fillet

Substrate

Shelterbit 2nd layer torched to substrate through vent sheet

Shelterbit Mineral

Vented Base Sheet

SKYLIGHT FLASHING

Cover flashing extends under skylight moulding

Shelterbit base sheet to substrate

Fillet

Substrate

SCUPPER OUTLET

Shelterbit MembraneFlashing

External Rainhead

Scupper

Substrate

Shelterbit Membrane

SCUPPER OUTLET

Shelterbit Membrane

BT 305 Bend

BT 302 Scupper

Substrate

Shelterbit Membrane

8

OUTSIDE CORNER

PIPE FLASHING

ONE WAY VENT INSTALLATION

Fillet

SubstrateShelterbit Base Sheet torched to substrate

STEP 1 STEP 2

STEP 2

STEP 1

Flashing prior to installation

Parallel Cuts

Pipe

Shelterbit flashing torched in place

Substrate

Top Shelterbit sheet cut to fit around pipe

Mineral Cap Sheet One Way Roof Vent

Vented Base Sheet2nd Layer

Mineral Cap Sheet

One Way Roof Vent

Vented Base Sheet

Aerators

VapourMembranes

Vent SheetPorous Concrete Decking

Partial Bonding through Vapour Equalisation Layer

Flashing Metal Sleeve

Typical details do not indicate number of layers required9

BELOW GROUND DETAIL

ALTERNATIVE OPTION

ARDEX Shelterbit MembranesInstallation Details

TANKING OF LIFT PIT BELOW WATER TABLE

Protection Board

Sheet piling andformwork

Vertical Shelterbit Membrane

StructuralFloor Slab

Steel reinforcing Protection

Screed

Horizontal Shelterbit MembraneBlinding Slab

Protection Board

Sheet piling andformwork

Vertical ShelterbitMembrane

StructuralFloor Slab

Steel reinforcing Protection

Screed

Horizontal Shelterbit MembraneSite Concrete

Protection Board

Shelterbit Membrane

Protection Screed

Foundations Underlayers

Typical details do not indicate number of layers required

Back Fill

Back Fill

Back Fill

Shelterbit Membrane

EAVE AND VERGES IN SHELTERBIT

Roofing membrane

Upstand framing

Fillet

Substrate

Metal flashing

Wall cladding and building wrap

Z

Membrane dressed down over barge flashing and returned at ends

NOTE: Z = variable according to wind zone

March201210

BRANZ Appraisals

Technical Assessments of products for building and construction

BRANZ LimitedPrivate Bag 50 908

Porirua CityNew Zealand

Tel: +64 4 237 1170Fax: +64 4 237 1171www.branz.co.nz

Readers are advised to check the validity of this Appraisal by referring to the Valid Appraisals listing on the BRANZ website, or by contacting BRANZ.

BRANZAPPRAISAL

No. 463 (2011)

SheLTeRBIT RooFINg memBRANeS

Ardex New Zealand LimitedP O Box 19549

Christchurch

Tel: 03 384 3029Fax: 03 384 9779

Web: www.butynol.co.nz

Appraisal No.463 [2011]

Product 1.1 Shelterbit Roofing Membranes are waterproofing membranes for nominally flat, pitched and curved roofs, gutters and parapets. They are installed as multi-layer system with a mineral chip finished product or as a single layer system onto a concrete substrate under heavy protection such as paving slabs or a topping screed.1.2 The products are supplied as torch-on, reinforced, polymer-modified bitumen sheets in roll form.

Scope2.1 Shelterbit Roofing Membranes have been appraised as roof waterproofing membranes on buildings within the following scope:

the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with respect to building height and maximum floor plan areas; and,with building structures designed and constructed to meet the requirements of the NZBC; and, with roof supporting structures of timber framing with substrates of plywood; and,with substrates of suspended concrete slabs; and,situated in NZS 3604 Building Wind Zones, up to, and including ‘Extra High’.

2.2 Shelterbit Roofing Membranes have also been appraised for use as roof waterproofing membranes on specifically designed buildings within the following scope:

with building structures designed and constructed to comply with the NZBC; and,with roof supporting structures of timber framing with substrates of plywood; and,with substrates of suspended concrete slab; and,subjected to maximum wind pressures (Refer Paragraph 8.1); and, with the weathertightness design of all junctions being the subject of specific design by the designer.

Note: The design of these junctions has not been appraised by BRANZ and is outside the scope of this Appraisal.2.3 Roofs waterproofed with Shelterbit Roofing Membranes must be designed and constructed in accordance with the following limitations:

nominally flat, curved or pitched roofs constructed to drain water to gutters and drainage outlets complying with the NZBC; and,constructed to suitable falls (Refer Paragraph 14.3 and 14.4); and, with no integral roof gardens.

2.4 The design and construction of the substrate and movement and control joints is specific to each building, and therefore is the responsibility of the building designer and building contractor and is outside the scope of this Appraisal.2.5 The membranes must be installed by Ardex New Zealand Ltd Trained Installers.

This Appraisal replaces BRANZ Appraisal No. 463 (2005) dated

31 January 2005.

2

Building Regulations

New Zealand Building Code (NZBC)3.1 In the opinion of BRANZ, Shelterbit Roofing Membranes, if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet the following provisions of the NZBC:Clause B2 DURABILITY: Performance B2.3.1 (b), 15 years. Shelterbit Roofing Membranes meet this requirement. See Paragraph 10.1. Clause E2 EXTERNAL MOISTURE: Performance E2.3.1 and E2.3.2. Shelterbit Roofing Membranes meets these requirements. See Paragraphs 14.1 – 14.9.Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Shelterbit Roofing Membranes meet this requirement and will not present a health hazard to people.

3.2 This is an Appraisal of an Alternative Solution in terms of New Zealand Building Code compliance. The membranes are an alternative to the membranes specified in NZBC Acceptable Solution E2/AS1, and an Alternative Solution subject to specific design for other buildings not covered within E2/AS1.

Technical Specification 4.1 Materials supplied by Ardex New Zealand Ltd are as follows:

Shelterbit Membranes GeneralThese are general torch-on membranes used either as single layer protected systems or as base and intermediate layers in built-up systems. They are supplied in thicknesses of 2.5, 3.5 or 4.0 mm and have a sand finish top surface and a thermofusible film backing. The 4.0 mm thick membrane must be used for single layer protected systems.

Shelterbit MineralA 4.0 mm thick (excluding the slate finish) torch-on membrane with a slate finish top surface and a thermofusible thermoplastic film backing. It is designed to be used as the cap layer and is available in grey, green, white, black or red.

Shelterbit Duo Mineral MembraneA 4.0 mm thick (excluding the slate finish) SBS/APP plastomeric type modified bitumen torch-on membrane with a mineral top surface and an embossed bottom surface protected by a heat sensitive polythene film. It is designed to be used as the cap layer and is available in various colours.

Ardex WPM 150 ShelterstickA 2.0 mm thick self-adhesive bituminous membrane with a thermo fusion film backing. It is designed to be used as a base layer on heat sensitive substrates.

Shelterbit Fibre-backed Base SheetA 2.7 mm thick membrane with a polythene top surface and a polyester fleece backing for adhesive fixing. It is designed to be used as a base sheet when adhesive fixed over plywood substrates.

Shelterbit Vented Base SheetA 0.8 mm thick APP sheet with a torchable film on the upper and lower surface. The sheet contains 119, 40 mm holes per square metre. It is designed to be used as the base sheet in a multi-layer system on a concrete substrate. It must not be counted as a waterproofing layer in a multi-layer system.

Shelterbit PrimerA solvent-based, bitumen modified, black liquid primer available in 5 and 20 litre cans.

Shelter AdhesiveA solvent-based contact adhesive in 4 and 20 litre cans.

Handling and Storage5.1 Handling and storage of all materials whether on or off site is under the control of the Ardex New Zealand Trained Installers. Dry storage must be provided for all products and the rolls of membrane must be stored in an upright position.

Technical Literature 6.1 Refer to the Appraisals listing on the BRANZ website for details of the current Technical Literature for the Shelterbit Roof Membranes. The Technical Literature must be read in conjunction with this Appraisal. All aspects of design, use, installation and maintenance contained in the Technical Literature and within the scope of this Appraisal must be followed.

Design Information

General7.1 Shelterbit Roofing Membranes are for use on roofs, gutters and parapets where an impervious waterproof membrane is required to prevent damage to building elements and adjoining areas. The products can be used on new or existing buildings. Ardex New Zealand Limited should be consulted as to the suitability of any existing substrates prior to using Shelterbit Roofing Membranes.7.2 The effective control of internal moisture must be considered at the design stage due to the impermeability of the membranes. Refer to BRANZ publication “Good Practice Guide - Membrane Roofing”.7.3 The Shelterbit General Membrane is designed for use on roofs and gutters as the first layer of a double layer system and all areas requiring detailing such as upstands, protrusions, rainwater heads and outlets. The Shelterbit Mineral and Duo Mineral Membrane are used as the top layer of double layer systems.

Structure8.1 Shelterbit Roofing Membranes fully bonded double layer systems are suitable for use in areas subject to maximum wind pressures of 6kPa Ultimate Limit State.

SubstratesPlywood9.1 Plywood must be treated to H3 (CCA treated). LOSP treated plywood must not be used. Plywood must comply with NZBC Acceptable Solution E2/AS1 Paragraph 8.5.3 and 8.5.5. Where specific design is used (i.e. outside the scope of E2/AS1) the plywood thickness and fixing size may increase and centres may decrease to meet specific wind loadings. Timber framing must comply with NZS 3604, or where specific engineering design is used, the framing shall be of at least equivalent stiffness to the framing provisions of NZS 3604, or comply with the serviceability criteria of AS/NZS 1170. In all cases, framing

2

Building Regulations

New Zealand Building Code (NZBC)3.1 In the opinion of BRANZ, Shelterbit Roofing Membranes, if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet the following provisions of the NZBC:Clause B2 DURABILITY: Performance B2.3.1 (b), 15 years. Shelterbit Roofing Membranes meet this requirement. See Paragraph 10.1. Clause E2 EXTERNAL MOISTURE: Performance E2.3.1 and E2.3.2. Shelterbit Roofing Membranes meets these requirements. See Paragraphs 14.1 – 14.9.Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Shelterbit Roofing Membranes meet this requirement and will not present a health hazard to people.

3.2 This is an Appraisal of an Alternative Solution in terms of New Zealand Building Code compliance. The membranes are an alternative to the membranes specified in NZBC Acceptable Solution E2/AS1, and an Alternative Solution subject to specific design for other buildings not covered within E2/AS1.

Technical Specification 4.1 Materials supplied by Ardex New Zealand Ltd are as follows:

Shelterbit Membranes GeneralThese are general torch-on membranes used either as single layer protected systems or as base and intermediate layers in built-up systems. They are supplied in thicknesses of 2.5, 3.5 or 4.0 mm and have a sand finish top surface and a thermofusible film backing. The 4.0 mm thick membrane must be used for single layer protected systems.

Shelterbit MineralA 4.0 mm thick (excluding the slate finish) torch-on membrane with a slate finish top surface and a thermofusible thermoplastic film backing. It is designed to be used as the cap layer and is available in grey, green, white, black or red.

Shelterbit Duo Mineral MembraneA 4.0 mm thick (excluding the slate finish) SBS/APP plastomeric type modified bitumen torch-on membrane with a mineral top surface and an embossed bottom surface protected by a heat sensitive polythene film. It is designed to be used as the cap layer and is available in various colours.

Ardex WPM 150 ShelterstickA 2.0 mm thick self-adhesive bituminous membrane with a thermo fusion film backing. It is designed to be used as a base layer on heat sensitive substrates.

Shelterbit Fibre-backed Base SheetA 2.7 mm thick membrane with a polythene top surface and a polyester fleece backing for adhesive fixing. It is designed to be used as a base sheet when adhesive fixed over plywood substrates.

Shelterbit Vented Base SheetA 0.8 mm thick APP sheet with a torchable film on the upper and lower surface. The sheet contains 119, 40 mm holes per square metre. It is designed to be used as the base sheet in a multi-layer system on a concrete substrate. It must not be counted as a waterproofing layer in a multi-layer system.

Shelterbit PrimerA solvent-based, bitumen modified, black liquid primer available in 5 and 20 litre cans.

Shelter AdhesiveA solvent-based contact adhesive in 4 and 20 litre cans.

Handling and Storage5.1 Handling and storage of all materials whether on or off site is under the control of the Ardex New Zealand Trained Installers. Dry storage must be provided for all products and the rolls of membrane must be stored in an upright position.

Technical Literature 6.1 Refer to the Appraisals listing on the BRANZ website for details of the current Technical Literature for the Shelterbit Roof Membranes. The Technical Literature must be read in conjunction with this Appraisal. All aspects of design, use, installation and maintenance contained in the Technical Literature and within the scope of this Appraisal must be followed.

Design Information

General7.1 Shelterbit Roofing Membranes are for use on roofs, gutters and parapets where an impervious waterproof membrane is required to prevent damage to building elements and adjoining areas. The products can be used on new or existing buildings. Ardex New Zealand Limited should be consulted as to the suitability of any existing substrates prior to using Shelterbit Roofing Membranes.7.2 The effective control of internal moisture must be considered at the design stage due to the impermeability of the membranes. Refer to BRANZ publication “Good Practice Guide - Membrane Roofing”.7.3 The Shelterbit General Membrane is designed for use on roofs and gutters as the first layer of a double layer system and all areas requiring detailing such as upstands, protrusions, rainwater heads and outlets. The Shelterbit Mineral and Duo Mineral Membrane are used as the top layer of double layer systems.

Structure8.1 Shelterbit Roofing Membranes fully bonded double layer systems are suitable for use in areas subject to maximum wind pressures of 6kPa Ultimate Limit State.

SubstratesPlywood9.1 Plywood must be treated to H3 (CCA treated). LOSP treated plywood must not be used. Plywood must comply with NZBC Acceptable Solution E2/AS1 Paragraph 8.5.3 and 8.5.5. Where specific design is used (i.e. outside the scope of E2/AS1) the plywood thickness and fixing size may increase and centres may decrease to meet specific wind loadings. Timber framing must comply with NZS 3604, or where specific engineering design is used, the framing shall be of at least equivalent stiffness to the framing provisions of NZS 3604, or comply with the serviceability criteria of AS/NZS 1170. In all cases, framing

3

must be provided so that the maximum span of the substrate as specified by the substrate manufacturer is met and all sheet edges are fully supported.

Concrete9.2 Concrete substrates must be to a specific engineering design meeting the requirements of the NZBC, such as concrete construction to NZS 3101.

Existing Construction9.3 A thorough inspection of the substrate must be made to ensure it is in fit condition and does not contain any materials that will adversely affect the performance of the membrane.9.4 Repairs must be undertaken, where applicable, to ensure the substrate is sound, the joints are sealed, and the flashings are sound. Plywood substrates must be checked for screw fixings, and if necessary refixed as for new plywood.

DurabilityServiceable Life10.1 Shelterbit Roofing Membranes are expected to have a serviceable life of at least 15 years, provided they are designed, used, installed and maintained in accordance with this Appraisal and the Technical Literature.

Chemical Resistance10.2 Industrial air pollutants and windborne salt deposits should not significantly affect the durability of the membranes. However, the long term properties of the material may be affected by contact with petroleum-based products such as oils, greases and solvents.

Maintenance11.1 The membrane roof system, including any areas with a UV coating applied, must be regularly (at least annually) checked for damage, rubbish, debris or coating breakdown. Damage, such as small punctures and tears must be repaired and coatings reapplied as recommended by Ardex New Zealand Ltd.11.2 Special care must be taken when inspecting the membrane roof systems to ensure the continuing prevention of moisture ingress, and repairs must be undertaken where required.11.3 Drainage outlets must be maintained to operate effectively.

Outbreak of Fire12.1 Separation or protection must be provided to the membranes and plywood substrate from heat sources such as flues and chimneys.12.2 NZBC Acceptable Solution C/AS1 Part 9 and Verification Method C/VM1 provide methods for separation and protection of combustible materials from heat sources.

Spread of Fire13.1 The membranes may be used on roofs of buildings intended for all Purpose Groups, including SC and SD, subject to the requirements of NZBC Acceptable Solution C/AS1 Part 7, Paragraph 7.11.1.13.2 The membranes may be used for cladding fire-rated roof construction, providing the roof construction complies with the requirements of NZBC Acceptable Solution C/AS1 Part 7.

External Moisture14.1 Roofs must be designed and constructed to shed precipitated moisture. They must also take account of snowfalls in snow prone areas. A means of meeting code compliance with NZBC Clause E2.3.1 is given by the Technical Literature which aligns with details in NZBC Acceptable Solution E2/AS1.14.2 When installed in accordance with this Appraisal and the Technical Literature, Shelterbit Roofing Membranes will prevent the penetration of water and will therefore meet code compliance with Clause E2.3.2. The membranes are impervious to water and will give a weathertight roof.14.3 Roof falls must be built into the substrate and not created with mortar screeds applied over the membrane.14.4 The minimum fall to roofs is 1 in 30 and gutters are 1 in 60. All falls must slope to an outlet. Inadequate falls will allow moisture to collect and increase the risk of deterioration of the membrane.14.5 Allowance for deflection and settlement of the substrate must be made in the design of the roof to ensure falls are maintained and no ponding of water can occur.14.6 Shelterbit Roofing Membranes are impermeable; therefore a means of dissipating construction moisture must be provided in the building design and construction to meet code compliance with Clause E2.3.6.14.7 Drainage flanges must be used for any outlet and must be fitted with a grate or cage to reduce potential sources of blockages. An overflow must be provided where the roof does not drain to an external gutter or spouting. 14.8 Penetrations and upstands of the membranes must be raised above the level of any possible flooding caused by the blockage of roof drainage.14.9 The design of details not covered by the Technical Literature is subject to specific weathertightness design and is outside the scope of this Appraisal.

Water Supplies15.1 Shelterbit Roofing Membranes have not been assessed for roofs used for the collection of potable water.

Installation Information

Installation Skill Level Requirement16.1 Installation of the membranes must be completed by Ardex New Zealand Ltd Trained Installers. 16.2 Installation of substrates must be completed by tradespersons with an understanding of roof construction, in accordance with instructions given within the Ardex New Zealand Ltd Technical Literature and this Appraisal.

Preparation of Substrates17.1 Substrates must be dry, clean and stable before installation commences. Surfaces must be smooth and free from nibs, sharp edges, dust, dirt or other materials such as oil, grease or concrete formwork release agents. All surface defects must be filled to achieve an even and uniform surface.17.2 The relative humidity of concrete substrates must be 75% or less before membrane application. The concrete can be checked for dryness by using a hygrometer, as set out in BRANZ Bulletin No. 424. 17.3 The moisture content of the plywood and timber substructure must be a maximum of 20% and the plywood sheets must be dry at time of membrane application. This will generally require plywood sheets to be covered until just before the membrane is laid, to prevent rain wetting.

4

17.4 All substrates must be primed with Shelterbit Primer and left to dry (1 hour) before the membrane is installed.

Membrane Installation18.1 The membranes must be installed in accordance with the Technical Literature. 18.2 All roof and wall junctions must have a 20 mm x 20 mm wooden fillet installed at the junction. Concrete substrate junctions must have a 20 mm x 20 mm cement mortar fillet installed. All external edges must be chamfered to a 5 mm radius to remove sharp edges.18.3 The membrane must be unrolled without tension onto the prepared substrate and allowed to ‘relax’ for at least 30 minutes prior to installation.18.4 The membrane is installed from the lowest point and each layer is installed across the roof fall allowing a 100 mm side overlap and a 200 mm end overlap. The cap sheet layer must be offset against the base sheet layer.

Inspections19.1 Critical areas of inspection for waterproofing systems are:

Construction of substrates, including crack control and installation of bond breakers and movement control joints.Moisture content of the substrate prior to the application of the membrane.Acceptance of the substrate by the membrane installer prior to application of the membrane.Installation of the membrane to the manufacturer’s instructions.

Health and Safety20.1 Safe use and handling procedures for Shelterbit Roofing Membranes are provided in the Technical Literature. The products must be used in conjunction with the relevant Material Safety Data Sheets for each membrane.

Basis of Appraisal The following is a summary of the technical investigations carried out:

Tests21.1 Testing of Phoenix Star and Phoenix Star Mineral (Shelterbit Membranes) have been undertaken by ICITE, which formed the basis of the technical investigations and evaluation undertaken by the British Board of Agrément (BBA) for issue of the current BBA Certificate covering these products. This testing covered: tensile strength, elongation at break, tear strength, dimensional stability, low temperature flexibility, heat resistance, unrolling at low temperatures, sliding resistance, watertightness, static indentation, dynamic indentation, fatigue cycling, peel resistance, softening point, penetration, air pressure of joints, tensile strength of joints and peel strength of joints. Some testing covered heat aged, UV aged and water soaked samples as well as controls. 21.2 The Shelterbit Duo has been tested for tensile, elongation, tear resistance, adhesion of granules, dimensional stability, flow resistance and pliability at low temperature and is a CE marked product.

The above test methods and results have been reviewed by BRANZ and found to be satisfactory.

Other Investigations22.1 A durability opinion has been provided by BRANZ technical experts.22.2 Installation of the membranes has been assessed by BRANZ for practicability of installation and found to be satisfactory.22.3 The Technical Literature has been examined by BRANZ and found to be satisfactory.

Quality23.1 The manufacture of the membranes and primer has not been examined by BRANZ, but details regarding the quality and composition of the materials used were obtained by BRANZ and found to be satisfactory. An examination of the manufacturing practice and quality control procedures employed in the manufacture of the membranes is subject to the ongoing validity of the current BBA Certificate. 23.2 The quality of the supply of products to the New Zealand market is the responsibility of Ardex New Zealand Ltd. 23.3 Quality on site is the responsibility of the Ardex New Zealand Ltd Trained Installers. 23.4 Designers are responsible for the building design, and building contractors are responsible for the quality of construction of substrate systems in accordance with the instructions of Ardex New Zealand Ltd and this Appraisal.23.5 Building owners are responsible for the maintenance of the membrane systems in accordance with the instructions of Ardex New Zealand Ltd and this Appraisal.

Sources of InformationAS/NZS 2269: 2008 Plywood – structural.AS/NZS 1170: 2002 Structural design actions.BBA Certificate No. 99/3586/C Phoenix Star and Phoenix Star Mineral Roof Waterproofing Membranes.BRANZ Good Practice Guide – Membrane Roofing, reprint October 2003.NZS 3101: 1995 The design of concrete structures.NZS 3604: 2011 Timber framed buildings.Compliance Document for New Zealand Building Code External Moisture Clause E2, Department of Building and Housing, Third Edition July 2005 (including Amendment 5, 1 August 2011).New Zealand Building Code Handbook Department of Building and Housing, Third Edition September 2010.The Building Regulations 1992.

4

17.4 All substrates must be primed with Shelterbit Primer and left to dry (1 hour) before the membrane is installed.

Membrane Installation18.1 The membranes must be installed in accordance with the Technical Literature. 18.2 All roof and wall junctions must have a 20 mm x 20 mm wooden fillet installed at the junction. Concrete substrate junctions must have a 20 mm x 20 mm cement mortar fillet installed. All external edges must be chamfered to a 5 mm radius to remove sharp edges.18.3 The membrane must be unrolled without tension onto the prepared substrate and allowed to ‘relax’ for at least 30 minutes prior to installation.18.4 The membrane is installed from the lowest point and each layer is installed across the roof fall allowing a 100 mm side overlap and a 200 mm end overlap. The cap sheet layer must be offset against the base sheet layer.

Inspections19.1 Critical areas of inspection for waterproofing systems are:

Construction of substrates, including crack control and installation of bond breakers and movement control joints.Moisture content of the substrate prior to the application of the membrane.Acceptance of the substrate by the membrane installer prior to application of the membrane.Installation of the membrane to the manufacturer’s instructions.

Health and Safety20.1 Safe use and handling procedures for Shelterbit Roofing Membranes are provided in the Technical Literature. The products must be used in conjunction with the relevant Material Safety Data Sheets for each membrane.

Basis of Appraisal The following is a summary of the technical investigations carried out:

Tests21.1 Testing of Phoenix Star and Phoenix Star Mineral (Shelterbit Membranes) have been undertaken by ICITE, which formed the basis of the technical investigations and evaluation undertaken by the British Board of Agrément (BBA) for issue of the current BBA Certificate covering these products. This testing covered: tensile strength, elongation at break, tear strength, dimensional stability, low temperature flexibility, heat resistance, unrolling at low temperatures, sliding resistance, watertightness, static indentation, dynamic indentation, fatigue cycling, peel resistance, softening point, penetration, air pressure of joints, tensile strength of joints and peel strength of joints. Some testing covered heat aged, UV aged and water soaked samples as well as controls. 21.2 The Shelterbit Duo has been tested for tensile, elongation, tear resistance, adhesion of granules, dimensional stability, flow resistance and pliability at low temperature and is a CE marked product.

The above test methods and results have been reviewed by BRANZ and found to be satisfactory.

Other Investigations22.1 A durability opinion has been provided by BRANZ technical experts.22.2 Installation of the membranes has been assessed by BRANZ for practicability of installation and found to be satisfactory.22.3 The Technical Literature has been examined by BRANZ and found to be satisfactory.

Quality23.1 The manufacture of the membranes and primer has not been examined by BRANZ, but details regarding the quality and composition of the materials used were obtained by BRANZ and found to be satisfactory. An examination of the manufacturing practice and quality control procedures employed in the manufacture of the membranes is subject to the ongoing validity of the current BBA Certificate. 23.2 The quality of the supply of products to the New Zealand market is the responsibility of Ardex New Zealand Ltd. 23.3 Quality on site is the responsibility of the Ardex New Zealand Ltd Trained Installers. 23.4 Designers are responsible for the building design, and building contractors are responsible for the quality of construction of substrate systems in accordance with the instructions of Ardex New Zealand Ltd and this Appraisal.23.5 Building owners are responsible for the maintenance of the membrane systems in accordance with the instructions of Ardex New Zealand Ltd and this Appraisal.

Sources of InformationAS/NZS 2269: 2008 Plywood – structural.AS/NZS 1170: 2002 Structural design actions.BBA Certificate No. 99/3586/C Phoenix Star and Phoenix Star Mineral Roof Waterproofing Membranes.BRANZ Good Practice Guide – Membrane Roofing, reprint October 2003.NZS 3101: 1995 The design of concrete structures.NZS 3604: 2011 Timber framed buildings.Compliance Document for New Zealand Building Code External Moisture Clause E2, Department of Building and Housing, Third Edition July 2005 (including Amendment 5, 1 August 2011).New Zealand Building Code Handbook Department of Building and Housing, Third Edition September 2010.The Building Regulations 1992.

In the opinion of BRANZ, Shelterbit Roofing Membranes are fit for purpose and will comply with the Building Code to the extent specified in this Appraisal provided they are used, designed, installed and maintained as set out in this Appraisal.The Appraisal is issued only to Ardex New Zealand Ltd, and is valid until further notice, subject to the Conditions of Appraisal.

Conditions of Appraisal1. This Appraisal: a) relates only to the product as described

herein;b) must be read, considered and used in full

together with the technical literature;c) does not address any Legislation,

Regulations, Codes or Standards, not specifically named herein;

d) is copyright of BRANZ.2. Ardex New Zealand Ltd:a) continues to have the product reviewed by

BRANZ;b) shall notify BRANZ of any changes in

product specification or quality assurance measures prior to the product being marketed;

c) abides by the BRANZ Appraisals Services Terms and Conditions.

d) Warrants that the product and the manufacturing process for the product are maintained at or above the standards, levels and quality assessed and found satisfactory by BRANZ pursuant to BRANZ’s Appraisal of the product.

3. BRANZ makes no representation or warranty as to:

a) the nature of individual examples of, batches of, or individual installations of the product, including methods and workmanship;

b) the presence or absence of any patent or similar rights subsisting in the product or any other product;

c) any guarantee or warranty offered by ArdexNew Zealand Ltd.

4. Any reference in this Appraisal to any other publication shall be read as a reference to the version of the publication specified in this Appraisal.

5. BRANZ provides no certification, guarantee, indemnity or warranty, to ArdexNew Zealand Ltd or any third party.

For BRANZ

P BurghoutChief Executive

Date of issue: 8 August 2011

Black

ARDEX Shelterbit Phoenix Star (Mineral)Colour Range

Green

OffWhite

DarkGrey

Red

Coloursshownmayvaryfromactualmaterialsamples.Pleasecheckactualcolourofmaterialbeforeordering.

16

ARDEX WPM 555Shelterbit Phoenix Star (Mineral)

4.1mm+mineralReinforcedAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

17

ARDEX WPM 555Shelterbit Phoenix Star (Mineral)4.1mm + mineral Reinforced APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM555(ShelterbitPhoenixStar)isanAPP(AtacticPolypropylene)plastomerictypemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithacombinedreinforcement(PolyesterandFibreglass).ArdexWPM555(ShelterbitPhoenixStar)iscertifiedinGreatBritainwithBBANo99/3586/CandinItalywithTechnicalAgreementI.T.C.591/03.ArdexWPM555(ShelterbitPhoenixStar)iscoatedwithaslatemineralgranuletopping,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

• Positivevapourbarrier• Excellentresistancetoatmosphericagentscold

flexibility-15°C• Excellentelongation• Resistanttochemicalattacks• Withstandthermalshocks• Heatweldedlapsprovideshomogenousjoint• Prefabricatedmembrane• Highpunctureresistance

USES

ArdexWPM555(ShelterbitPhoenixStar)membranecanbeusedasawatertight/finishinglayer.

Non-accessibleflatroofingAccessibleflatroofing

VaultcoveringRenovationandrefurbishment

INSTALLATION

TheapplicationofArdexWPM555(ShelterbitPhoenixStar)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM555(ShelterbitPhoenixStar)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.ArdexWPM555(ShelterbitPhoenixStar)isnormallyinstalledinamulti-layersystemincorporatingArdexBitumenmembranesorbasesheets.ArdexWPM555(ShelterbitPhoenixStar)isfullybondedtoplainorbaselayer.Overlapsarealwaystorch-bondedwithawidthof10cm.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM555(ShelterbitPhoenixStar)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM555(ShelterbitPhoenixStar)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize1mx8mRollweight:Approximately44kgRollsperpallet:23

AppraisalNo.463[2011]

18

Valuesarereferredtoamembraneof:Thickness4.1mm+mineralWeight5.2kg/m2

AlltestshavebeencarriedoutaccordingtoUEATCdirective

MEMBRANE

Characteristics Standard Units Nom.

Length UNIEN1848-1 m 8±1%

Width UNIEN1848-1 m 1±1%

Thickness UNIEN1849-1 mm 4.1 +mineral

AericMass UNIEN1849-1 kg/m2 5.2

HeatStability UNIEN1110 ºC 130

HeatStabilityAfter6monthsat70ºC UNIEN1110 ºC 130

ColdFlexibility UNIEN1109 ºC -15

ColdStability

After6monthsat70ºC UNIEN1109 ºC 0

DimensionalStabilityLongitudinal UNIEN1107-1A % ≤-0.3Transversal ≤+0.3

Impermeability UNIEN1928 kPa ≥60

TensileStrengthLongitudinalUltimateTensileStrength UNIEN12311-1 N/50mm 900TransversalUltimateTensileStrength 700

ElongationatBreakLongitudinal UNIEN12311-1 % 45Transversal 45

TearResistanceLongitudinal 150Transversal UNIEN12310-1 N 150

ResistancetoStaticLoad UNIEN12730 kg 25

MineralAdhesion UNIEN12039 % max30%

TECHNICAL DATA

COMPOUND

Characteristics Standard Units Nom. Tolerances

RingandBall ASTMD36 ºC 150 Valoremin

Penetrationat60ºC ASTMD5 dmm 120 Valoremin

ColdFlexibility UNIEN1109 ºC -15 Valoremin

ColdStabilityAfter6monthsat70ºC UNIEN1109 ºC 0 Valoremin

March2012 19

20

ARDEX WPM 444Shelterbit Phoenix Star (Plain)

4.1mmReinforcedAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

21

ARDEX WPM 444Shelterbit Phoenix Star (Plain)4.1mm Reinforced APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM444(ShelterbitPhoenixStar)isanAPP(AtacticPolypropylene)plastomerictypemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithacombinedreinforcement(polyesterandfibreglass).ArdexWPM444(ShelterbitPhoenixStar)iscertifiedinGreatBritainwithBBANo99/3586/CandinItalywithTechnicalAgreementI.T.C.591/03.ArdexWPM444(ShelterbitPhoenixStar)iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

APP modified compound• Excellentcoldflexibilityto-15°C• Excellentelongation• Heatweldedlapsprovideshomogenousjoint• Prefabricatedmembrane• Goodelasticmemory

Combined reinforcement carrier• Highmechanicalcharacteristics• Highpunctureresistance• Goodelongation• Willnotdecay

USES

ArdexWPM444(ShelterbitPhoenixStar)isdesignedforuseasamulti-layersystemonconcreteorplywoodsubstrates,orasasinglelayersystemonconcrete

substrateswithaprotectivetoppingsuchaspavingslabsorconcrete.Non-accessibleflatroofingAccessibleflatroofingFoundationsandundergroundpremisesVaultcoveringShedcoveringRenovationandrefurbishmentInvertedroofsystemsBridges,viaductsandroadstructuresCarparksTunnels

INSTALLATION

TheapplicationofArdexWPM444(ShelterbitPhoenixStar)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM444(ShelterbitPhoenixStar)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM444(ShelterbitPhoenixStar)basesubstratesurfacesshouldbeprimedwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM444(ShelterbitPhoenixStar)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM444(ShelterbitPhoenixStar)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.ArdexWPM444(ShelterbitPhoenixStar)isusedasasinglelayermembranesystemwhichisnormallyinstalledpriortotheinstallationoftoppings,roadbaseorhotmeltasphaltorbitumen.Applicationoftoppingsmaybeappliedoncompletion.Roadbasemaybeinstalleddirectlytothemembranewithoutanextraprotectionlayer.TheasphaltshouldbeappliedassoonaspossibleaftertheArdexWPM444(ShelterbitPhoenixStar)membranehasbeeninstalled.Ardexrecommendapplyingaminimum50mmcompactedoverlayforcarparkareas.Thetoppingshouldbeappliedintwolayersatatemperatureofbetween120-150°C.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

AppraisalNo.463[2011]

22

Valuesarereferredtoamembraneof:Thickness4.1mmWeight4.0kg/m2

AlltestshavebeencarriedoutaccordingtoUEATCdirective

MEMBRANE

Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10±1%

Width UNIEN1848-1 m 1±1%

Thickness UNIEN1849-1 mm 4.1

AericMass UNIEN1849-1 kg/m2 4.0

HeatStability UNIEN1110 ºC 130

HeatStabilityAfter6monthsat70ºC UNIEN1110 ºC 130

ColdFlexibility UNIEN1109 ºC -15

ColdStabilityAfter6monthsat70ºC UNIEN1109 ºC 0

DimensionalStabilityLongitudinal UNIEN1107-1A % ≤-0.3Transversal ≤+0.3

Impermeability UNIEN1928 kPa ≥60

TensileStrengthLongitudinalUltimateTensileStrength UNIEN12311-1 N/50mm 900TransversalUltimateTensileStrength 700

ElongationatBreakLongitudinal UNIEN12311-1 % 45Transversal 45

TearResistanceLongitudinal 150Transversal UNIEN12310-1 N 150

ResistancetoStaticLoad UNIEN12730 kg 25

MineralAdhesion UNIEN12039 % -

TECHNICAL DATA

COMPOUND

Characteristics Standard Units Nom. Tolerances

RingandBall ASTMD36 ºC 150 Valoremin

Penetrationat60ºC ASTMD5 dmm 120 Valoremin

ColdFlexibility UNIEN1109 ºC -15 Valoremin

ColdStabilityAfter6monthsat70ºC UNIEN1109 ºC 0 Valoremin

SAFETY PRECAUTIONS

ArdexWPM444(ShelterbitPhoenixStar)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM444(ShelterbitPhoenixStar)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx10mRollweight:Approximately40kgRollsperpallet:23

March2012 23

24

ARDEX WPM 115Shelterbit Vented Base Sheet

0.8mmAPPBitumenVentedBaseSheet

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

25

ARDEX WPM 115Shelterbit Vented Base Sheet0.8mm APP Bitumen Vented Base Sheet

PRODUCT DESCRIPTION

ArdexWPM115(ShelterbitVentedBaseSheet)isanAPP(AtacticPolypropylene)plastomerictypemodifiedbitumenmembraneventedbasesheet,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymers.AprotectiveheatsensitivepolythenefilmcoversbothsurfacesoftheBaseSheet.

FEATURES/BENEFITS

•Isaspeciallydesignedperforatedbase-sheetforuseinamulti-layerwaterproofingsystem.•Virtuallyeliminatesbubblesandblistersformingunderneaththewaterproofinglayer.•Allowsvapourpermeatingthroughthedecktodiffuseunderneaththewaterproofingwhere,ideally,aeratorswillbeinstalledtoallowthevapourtoescapetoatmosphere.•Eliminatesthecreationofstressesinthewaterproofinglayersthusgreatlyreducingfailuresinthewaterproofingcausedbydeckmovements.•Istheidealsolutionforcontrolled,partiallyattachedfirstlayerinamulti-layersystem.

INSTALLATION

TheapplicationofArdexShelterbitshouldbecarriedoutbyanapprovedApplicator.

ConcreteAfterprimingofsubstrateArdexWPM115(ShelterbitVentedBaseSheet)maybelooselaidormaybetackedinplacetolocatesheetuntilnextlayerisinstalled.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexShelterbitistobeinstalledmustbeproperlypreparedpriortomembraneinstallation.ArdexShelterbitmaybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexShelterbitisnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexShelterbitshouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx20mRollweight:Approximately20kgRollsperpallet:33

AppraisalNo.463[2011]

26

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM115(ShelterbitVentedBaseSheet).Characteristics Standard Units Nom.

Length UNIEN1848-1 m 20

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 0.8

HoleDiameter mm 40

NumberofHoles perm2 119

HeatStability UNIEN1110 °C 110

ColdFlexibility UNIEN1109 °C -5

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 310

UltimateTransverse N/5 cm 205

ElongationatBreak UNIEN12311-1

Longitudinal % 2

Transverse % 2

Tearresistance UNIEN12310-1

Longitudinal N 70

Transverse N 80

Reinforcement GlassFibre g.s.m. 60

Surfacefinishes Lower1 torchfilm

Top2 torchfilm

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 27

ArdexWPM116ShelterbitFibreBacked(Top)

ArdexWPM116ShelterbitFibreBacked(Bottom)

ARDEX Shelterbit

ArdexWPM116isanAPPmodifiedbitumenmembranesliporbasesheetreinforcedwithacombinationoffibreglassandnon-wovenpolyester.Thetopsurfaceisprotectedbyaheatsenstivepolythenefilmandthelowersurfaceisplainuncoatedpolyester.

APP modified compound• Excellentelongation• Coldflexibility-5°C• Excellentresistancetopollutants• Goodelasticmemory

Non-woven polyester mat• Goodmechanicalcharacteristics• Gooddimensionalstability• Goodpunctureresistance• Willnotdecay• Goodelongation

28

ARDEX WPM 116Shelterbit Fibre Backed Base Sheet

2.7mmAPPBitumenFibreBackedBaseSheet

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

29

ARDEX WPM 116Shelterbit Fibre Backed Base Sheet2.7mm APP Bitumen Fibre Backed Base Sheet

PRODUCT DESCRIPTION

ArdexWPM116(ShelterbitFibreBackedBaseSheet)isanAPP(AtacticPolypropylene)plastomerictypemodifiedbitumenmembranesliporbasesheet,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymers.Theproductisreinforcedwithacombinationoffibreglassandnon-wovenpolyester.ArdexWPM116(ShelterbitFibreBackedBaseSheet)topsurfaceisprotectedbyaheatsenstivepolythenefilm.Thelowersurfaceofthesliporbasesheetisplainuncoatedpolyester.

PHYSICAL AND CHEMICAL PROPERTIES

APP modified compound• Excellentelongation• Coldflexibility-5°C• Excellentresistancetopollutants• Goodelasticmemory

Non-woven polyester mat• Goodmechanicalcharacteristics• Gooddimensionalstability• Goodpunctureresistance• Willnotdecay• Goodelongation

USES

OnplywoodsubstratesArdexWPM116(ShelterbitFibreBackedBaseSheet)isnormallyinstalledasabasesheetinmulti-layersystemsfullyadheredusingArdexWA98Adhesive.ArdexWPM116(ShelterbitFibreBackedBaseSheet)hasbeenspecificallydesignedforapplicationstoheatsensitivesubstratessuchasplywooddecksorthermalinsulation.Alsocanbeinstalledasabase-layeronroughorun-evenconcretedecks.OverlapsarerequiredtobetorchsealedwhenArdexWPM116(ShelterbitFibreBackedBaseSheet)isusedasavapourcontrollayerorasasecondary-waterproofinglayer.

INSTALLATION

TheapplicationofArdexWPM116(ShelterbitFibreBackedBaseSheet)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM116(ShelterbitFibreBackedBaseSheet)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.ArdexWPM116(ShelterbitFibreBackedBaseSheet)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

Tostrengthenthelapanoverlapof75mmmustbeused.Thisis25mmoffibrebackingand50mmofplainselvedge.Thefibrebackingwhenmeltedintothelowersheetaddsstrengthtotheweld.

Anendlapisformedbyoverlapping100mmoffibrebackedmembraneontothesheetbelow.Acapsheetof150mmFibrepol120isthenweldedovertheendlaptopreventwaterwickinguptheexposedfibreandtoreinforceandsealtheendlap.

SIDE LAP BONDING DETAIL

Plywood

50mm selvedge25mm

150mm

100mm

Plywood

END LAP DETAIL

AppraisalNo.463[2011]

30

SAFETY PRECAUTIONS

ArdexWPM116(ShelterbitFibreBackedBaseSheet)isnotclassifiedasdangerousgoods.Duringinstallation,exercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerialssuchaswetadhesive.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM116(ShelterbitFibreBackedBaseSheet)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize1mx10m(Fleeceis0.95mwide).Rollweight:Approximately29kgRollsperpallet:28

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM116(ShelterbitFibreBackedBaseSheet).Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10

Width UNIEN1848-1 m 1.00

Thickness UNIEN1849-1 mm 2.7

AericMass UNIEN1849-1 kg/m2 3.0

HeatStability UNIEN1110 °C 110

ColdFlexibility UNIEN1109 °C -5

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 600

UltimateTransverse N/5 cm 350

ElongationatBreak UNIEN12311-1

Longitudinal % 60

Transverse % 60

Tearresistance UNIEN12310-1

Longitudinal N 100

Transverse N 100

Reinforcement

Polyester gsm 150

GlassFibre gsm 50

Surfacefinishes Lower1 polyester

Top2 torchfilm

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 31

32

ARDEX WPM 120Shelterbit Fibrepol 120 Membrane

2.5mmCombinedReinforcedAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

33

ARDEX WPM 120Shelterbit Fibrepol 120 Membrane2.5mm Combined Reinforced APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM120(ShelterbitFibrepol120)isanAPP(AtacticPolypropyleneplastomeric)typemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithacombinedreinforcementcarrier.ArdexWPM120(ShelterbitFibrepol120)iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

APP modified compound• Excellentcoldflexibilityto-5°C• Excellentelongation• Heatweldedlapsprovidehomogenousjoint• Prefabricatedmembrane• Goodelasticmemory

Combined reinforcement carrier• Highmechanicalcharacteristics• Highpunctureresistance• Willnotdecay

USES

ArdexWPM120(ShelterbitFibrepol120)isusedasabaseandormidlayerinmulti-layermembranesystemsinhorizontalorverticalapplicationsforwaterproofingbalconies,terracesandroofs.ArdexWPM120(ShelterbitFibrepol120)membraneisasandwichmembraneandmustbeprotectedfromUV.

INSTALLATION

TheapplicationofArdexWPM120(ShelterbitFibrepol120)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM120(ShelterbitFibrepol120)isinstalledmustbeproperlypreparedpriortomembranesinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM120(ShelterbitFibrepol120)thebasesubstratesurfacesshouldbeprimedwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM120(ShelterbitFibrepol120)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mmm.Overlapsshallbesealedbytorch.ArdexWPM120(ShelterbitFibrepol120)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexShelterbitisnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM120(ShelterbitFibrepol120)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx15mRollweight:45kgRollsperpallet:23

AppraisalNo.463[2011]

34

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM120(ShelterbitFibrepol120)WaterproofingMembrane.Characteristics Standard Units Nom.

Length UNIEN1848-1 m 15

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 2.5

AericMass UNIEN1849-1 kg/m2 2.9

HeatStability UNIEN1110 °C 110

ColdFlexibility UNIEN1109 °C -5

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 530

UltimateTransverse N/5 cm 400

ElongationatBreak UNIEN12311-1

Longitudinal % 35

Transverse % 40

Tearresistance UNIEN12310-1

Longitudinal N 120

Transverse N 120

Reinforcement Combined g.s.m. 120

Surfacefinishes Lower1 torchfilm

Top2 sand

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 35

36

ARDEX WPM 180Shelterbit Fibrepol 180 Membrane

3.5mmCombinedReinforcedAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

37

ARDEX WPM 180Shelterbit Fibrepol 180 Membrane3.5mm Combined Reinforced APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM180(ShelterbitFibrepol180)isanAPP(AtacticPolypropylene)plastomerictypemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithacombinedreinforcement(polyesterandfibreglass).ArdexWPM180(ShelterbitFibrepol180)iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

APP modified compound• Excellentcoldflexibilityto-5°C• Excellentelongation• Heatweldedlapsprovidehomogenousjoint• Prefabricatedmembrane• Goodelasticmemory

Combined reinforcement carrier• Highmechanicalcharacteristics• Highpunctureresistance• Goodelongation• Willnotdecay

USES

ArdexWPM180(ShelterbitFibrepol180)isusedasamulti-layermembraneinhorizontalorverticalapplicationsforwaterproofingbalconies,terracesandroofs.ArdexWPM180(ShelterbitFibrepol180)membraneisasandwichmembraneandmustbeprotectedfromUV.

INSTALLATION

TheapplicationofArdexWPM180(ShelterbitFibrepol180)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM180(ShelterbitFibrepol180)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM180(ShelterbitFibrepol180)basesubstratesurfacesshouldbeprimedwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM180(ShelterbitFibrepol180)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM180(ShelterbitFibrepol180)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM180(ShelterbitFibrepol180)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM180(ShelterbitFibrepol180)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx10mRollweight:Approximately42kgRollsperpallet:23

AppraisalNo.463[2011]

38

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM180(ShelterbitFibrepol180)WaterproofingMembrane.Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 3.5

AericMass UNIEN1849-1 kg/m2 4.2

HeatStability UNIEN1110 °C 110

ColdFlexibility UNIEN1109 °C -5

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 720

UltimateTransverse N/5 cm 420

ElongationatBreak UNIEN12311-1

Longitudinal % 40

Transverse % 45

Tearresistance UNIEN12310-1

Longitudinal N 130

Transverse N 130

Reinforcement Combined g.s.m. 180

Surfacefinishes Lower1 torchfilm

Top2 sand

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 39

40

ARDEX WPM 186Shelterbit Garden Membrane

3.5mmGardenAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

41

ARDEX WPM 186Shelterbit Garden Membrane3.5mm Garden APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM186(ShelterbitGarden)isanAPP(AtacticPolypropylene)plastomerictorchappliedmodifiedwaterproofingmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithahighqualitycombinedreinforcement(fibreglassandpolyester)andtreatedwithpreventivechemicaltostoprootsfromplantsdamagingthemembrane.ArdexWPM186(ShelterbitGarden)iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

• Positivevapourbarrier• Excellentresistancetopollutantsandaging• Maintainsshapestabilityathightemperatures• Highresistancetoperforation• Isrot-proof• Resistsrootsbothonmembraneandlaps• Goodelongationandflexibility• Heatweldedlapsprovideanhomogenousjoint

USES

ArdexWPM186(ShelterbitGarden)hasbeenespeciallyformulatedforthewaterproofingof:• Planterboxes• Gardenbeds• Roofgardens• Flowerbeds• GreencoveredcivilworksetcArdexWPM186(ShelterbitGarden)maybeinstalledinaoneormulti-layersystemincorporatingnormalShelterbit.ShelterbitGardenalwaysbeingthetoplayer.

INSTALLATION

TheapplicationofArdexWPM186(ShelterbitGarden)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM186(ShelterbitGarden)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM186(ShelterbitGarden)thesurfaceshouldbeprimedwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM186(ShelterbitGarden)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM186(ShelterbitGarden)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM186(ShelterbitGarden)isnotclassifiedasdangerousgoods.Howeverduringinstallation,exercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM186(ShelterbitGarden)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize1mx10mRollweight:Approximately42kgRollsperpallet:23

42

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM186(ShelterbitGarden)WaterproofingMembrane.Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 3.5

AericMass UNIEN1849-1 kg/m2 4.2

HeatStability UNIEN1110 °C 110

ColdFlexibility UNIEN1109 °C -5

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 720

UltimateTransverse N/5 cm 420

ElongationatBreak UNIEN12311-1

Longitudinal % 40

Transverse % 45

Tearresistance UNIEN12310-1

Longitudinal N 130

Transverse N 140

Reinforcement Combined g.s.m. 180

Surfacefinishes Lower1 torchfilm

Top2 sand

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 43

44

ARDEX WPM 122Shelterbit HD Bridge Membrane

5.0mmHeavyDutyBridge&DeckAPPBitumenMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

45

ARDEX WPM 122Shelterbit HD Bridge Membrane5.0mm Heavy Duty Bridge & Deck APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM122(ShelterbitHDBridgeMembrane)isanAPP(AtacticPolypropyleneplastomeric)typemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithahighqualitynon-woven300gpolyestercarrier.ArdexWPM122(ShelterbitHDBridgeMembrane)iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

APP modified compound• Excellentcoldflexibility-10°C• Excellentelongation• Heatweldedlapsprovidehomogenousjoint• Prefabricatedmembrane• Goodelasticmemory• Resistancetoaggressivechemicals

Heavyweight non-woven polyester• Highmechanicalcharacteristics• Highpunctureresistance• Goodelongation• Willnotdecay

USES

ArdexWPM122(ShelterbitHDBridgeMembrane)hasbeenspecificallyengineeredusingaheavyweightnon-wovencarrierforheavy-dutyapplications,particularlyasamembraneunderhotmeltasphaltorbitumen.Typicalusesare:• Bridgedecks• Carparks• Road-ways• ViaductsArdexWPM122(ShelterbitHDBridgeMembrane)isasandwichmembraneandmustbeprotectedfromUV.

INSTALLATION

TheapplicationofArdexWPM122(ShelterbitHDBridgeMembrane)shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM122(ShelterbitHDBridgeMembrane)systemsareinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM122(ShelterbitHDBridgeMembrane)thesurfaceshouldbeprimedwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM122(ShelterbitHDBridgeMembrane)isfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM122(ShelterbitHDBridgeMembrane)isusedasasinglelayermembranesystemwhichisnormallyinstalledpriortotheinstallationoftoppings,roadbaseorhotmeltasphaltorbitumen.Applicationoftoppingsmaybeappliedoncompletion.Roadbasemaybeinstalleddirectlytothemembranewithoutanextraprotectionlayer.TheasphaltshouldbeappliedassoonaspossibleaftertheArdexWPM122(ShelterbitHDBridgeMembrane)membranehasbeeninstalled.Ardexrecommendapplyingaminimum50mmcompactedoverlayforcarparkareas.Thetoppingshouldbeappliedintwolayersatatemperatureofbetween120-150°C.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM122(ShelterbitHDBridgeMembrane)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM122(ShelterbitHDBridgeMembrane)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

46

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM122(ShelterbitHDBridgeMembrane)WaterproofingMembrane.Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 5.0

AericMass UNIEN1849-1 kg/m2 5.2

HeatStability UNIEN1110 °C 120

ColdFlexibility UNIEN1109 °C -10

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 1,150

UltimateTransverse N/5 cm 950

ElongationatBreak UNIEN12311-1

Longitudinal % 45

Transverse % 50

Tearresistance UNIEN12310-1

Longitudinal N 200

Transverse N 200

Reinforcement Polyester g.s.m. 300

Surfacefinishes Lower1 torchfilm

Top2 sand

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

PACKAGING

Rollsize:1mx10mRollweight:Approximately52kgRollsperpallet:16

March2012 47

48

ARDEX WPM 191Shelterbit Fibrepol SBS

3.5mmSBSBitumenColdClimateMembrane

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

49

ARDEX WPM 191Shelterbit Fibrepol SBS3.5mm SBS Bitumen Cold Climate Membrane

PRODUCT DESCRIPTION

ArdexWPM191(ShelterbitFibrepolSBS)isahighperformanceStyrene-Butadine-Styrene(SBS)rubbermodifiedbitumenmembrane,reinforcedwithacombinedreinforcement(polyesterandfibreglass).TheexceptionalelongationpropertiesofSBScombinedwiththestrengthanddimensionalstabilityofthereinforcing,providesanexcellentwaterproofingmembranefornewandexistingconstructions.ArdexWPM191(ShelterbitFibrepolSBS).iscoatedwitheitherasandedortalctopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.

Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.

2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering.

FEATURES/BENEFITS

• Positivevapourbarrier• Excellentresistancetoatmosphereagents• Highflexibilityduringapplicationatsub-zero

temperaturewithnophysicalstrains• Highmalleability• Accommodatesstructuralmovements• Resistanttochemicalattacks• Withstandthermalshocks• Provenperformanceincolderregions• Goodelongationandflexibility

USES

ArdexWPM191(ShelterbitFibrepolSBS)isusedasasinglelayerormulti-layermembraneinhorizontalorverticalapplicationsforwaterproofingbalconies,terracesandflatroofs.ArdexWPM191(ShelterbitFibrepolSBS)membraneisasandwichmembraneandmustbeprotectedfromUV.ArdexWPM191(ShelterbitFibrepolSBS)isavailableinmineralfinishforexposedroofareas).

INSTALLATION

TheapplicationofArdexWPM191(ShelterbitFibrepolSBS).shouldbecarriedoutbyanapprovedApplicator.Installationshallbestrictlyinaccordancewiththemanufacturersrecommendations.AcceptablesubstratestowhichArdexWPM191(ShelterbitFibrepolSBS)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM191(ShelterbitFibrepolSBS)thesurfacemayrequireprimingwithArdexWPM240(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM191(ShelterbitFibrepolSBS)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM191(ShelterbitFibrepolSBS)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM191(ShelterbitFibrepolSBS)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM191(ShelterbitFibrepolSBS)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx10mRollweight:Approximately43kgRollsperpallet:23

50

TECHNICAL DATA

TheTechnicalDatashownherebelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM191(ShelterbitFibrepolSBS)WaterproofingMembrane.Characteristics Standard Units Nom.

Length UNIEN1848-1 m 10

Width UNIEN1848-1 m 1.0

Thickness UNIEN1849-1 mm 3.5

AericMass UNIEN1849-1 kg/m2 4.3

HeatStability UNIEN1110 °C 90

ColdFlexibility UNIEN1109 °C -20

Tensilestrength UNIEN12311-1

UltimateLongitudinal N/5 cm 720

UltimateTransverse N/5 cm 420

ElongationatBreak UNIEN12311-1

Longitudinal % 45

Transverse % 45

Tearresistance UNIEN12310-1

Longitudinal N 160

Transverse N 170

Reinforcement Combined g.s.m. 180

Surfacefinishes Lower1 torchfilm

Top2 torchfilm

Note1) Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.

Note2) Topsurface;exposedtoundersideofcoveringmembrane.

AlltestshavebeencarriedouttoUEATC,totolerancesasperEuropeanDirective.

March2012 51

52

ARDEX WPM 189Shelterbit Duo Mineral Membrane

4.5kg/m2MineralCoatedSBS/APPBitumenMembrane

Excellentresistancetoatmosphericagents

Resistanttochemicalattacks

Highpunctureresistance

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

53

ARDEX WPM 189Shelterbit Duo Mineral Membrane4.5kg/m2 Mineral Coated SBS/APP Bitumen Membrane

PRODUCT DESCRIPTION

ArdexWPM189(ShelterbitDuoMineralMembrane)isacombinedAPP(AtacticPolypropylene)andSBS(Styrene-Butadine-Styrene)plastomerictypemodifiedbitumenmembrane,consistingofaspeciallyformulatedbituminouscompoundofdistilledasphaltmodifiedwithselectedhighgradevisco-elasticpolymersandreinforcedwithacombinedreinforcement(polyesterandfibreglass).ArdexWPM189(ShelterbitDuoMineralMembrane)bottomlayercomprisesofanSBScompoundwhichgiveshighelasticityandexcellentflexibilityatlowtemperatures.ThetoplayeristhenformedfromAPPmodifiedbitumenwhichprovidesgoodcoldflexibilityandhighresistancetoheatandUVrays.ArdexWPM189(ShelterbitDuoMineralMembrane)iscoatedwithamineraltopsurfacefinish,whilethebottomsurfaceisembossedandprotectedbyaheatsensitivepolythenefilm.Thistypeoffinishforthelowersurfacehasbeenchosenfortwospecificpurposes.1.Toactasatemperaturegaugeduringapplication.Whenthefilmmeltsitshowsthatthecompoundisatthecorrecttemperature.2.Theembossingistoallowthegasestorapidlyescapewhenheatedtoitscorrectinstallationtemperatureavoidingpossibleproblemsofbubblingandblistering

FEATURES/BENEFITS

APP modified compound•Excellentelongation•Heatweldedlapsprovidehomogenousjoint•Prefabricatedmembrane•Goodelasticmemory

SBS modified compound•Excellentcoldflexibilityandelasticity•Excellentresistancetocracking•Improveddimensionalstability

Combined reinforcement carrier•Highmechanicalcharacteristics•Highpunctureresistance•Goodelongation•Willnotdecay

USES

ArdexWPM189(ShelterbitDuoMineralMembrane)isusedasamulti-layermembraneinhorizontalorverticalapplicationsforwaterproofingbalconies,terracesandroofs.ArdexWPM189(ShelterbitDuoMineralMembrane)isthefinallayerinthesystem

INSTALLATION

TheapplicationofArdexWPM189(ShelterbitDuoMineralMembrane)shouldbecarriedoutbyanapprovedApplicatorInstallationshallbestrictlyinaccordancewiththemanufacturer’srecommendations.AcceptablesubstratestowhichArdexWPM189(ShelterbitDuoMineralMembrane)istobeinstalledmustbeproperlypreparedpriortomembraneinstallation.Allsurfacesmustbedry,clean,smooth,freeofsharpedges,looseorforeignmaterials,oil,greaseandothermaterialswhichmaydamagethemembrane.PriortotheapplicationofArdexWPM189(ShelterbitDuoMineralMembrane)basesubstratesurfacesshouldbeprimedwithArdexWPM247(ShelterPrimer).Coverageofprimerwilldependontheporosityofthesubstrate.ArdexWPM189(ShelterbitDuoMineralMembrane)isnormallyfullybondedtothepreparedsubstratewithsidelapsof100mmandendlapsof150mm.Overlapsshallbesealedbytorch.ArdexWPM189(ShelterbitDuoMineralMembrane)maybeusedinvariouscombinationstoproduceavarietyofspecificationstailoredtosuittheindividualwaterproofingneed.Theexactspecificationwilldependonfunctionalandeconomicrequirements.AdviceshouldbesoughtforsuitablespecificationfromArdex.

SAFETY PRECAUTIONS

ArdexWPM189(ShelterbitDuoMineralMembrane)isnotclassifiedasdangerousgoods.Howeverduringinstallationexercisecautionwhenworkingwithopenflame.Examineallsurfacestowhichtheflamehasbeenappliedforsmoulderingorburningconditions.Donotuseopenflameonornearhighlycombustiblematerials.Followalllocalfirecodes.

STORAGE

AllrollsofArdexWPM189(ShelterbitDuoMineralMembrane)shouldbestoredinacoveredareaprotectedagainstsunlightandUVradiation.Rollsshouldbestoredinaverticalpositiononasmoothfloorsoasnottodamagetheedges.

PACKAGING

Rollsize:1mx10mRollweight:Approximately45kgRollsperpallet:23Thickness:4mm

54

TECHNICAL DATA

TheTechnicalDatashownbelowaretheaverageresultsoftheTests,MeasurementsandTrials,carriedoutonArdexWPM189(ShelterbitDuoMineralMembrane).

Characteristics Standard Nom/UnitsLength UNIEN1848-1 10mWidth UNIEN1848-1 1.0mAericMass UNIEN1849-1 4.5kg/m2

HeatStability UNIEN1110 100°CColdFlexibility UNIEN1109 -10°CTensilestrength UNIEN12311-1Ultimate 600mLongitudinal N/5cmUltimate 500mTransverse N/5cmElongationatBreak UNIEN12311-1Longitudinal 35%Transverse 35%Tearresistance UNIEN12310-1Longitudinal N150Transverse N150Surfacefinishes Lower1 TorchFilm Top2 MineralCoated

Note1)Lowersurface;thesurfacewhichisappliedtothestructurebeingwaterproofed.Note2)Topsurface;exposedtoweather.AlltestshavebeencarriedouttoUEATCDirective.

INSTALLATION RECOMMENDATIONS

Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

March2012 55

56

ARDEX Shelterbit Shingles

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

57

ARDEX Shelterbit Shingles

LAYING ARDEX SHELTERBIT SHINGLES

ArdexShelterbitShinglesaremadefroma4mmthickpolyesterandfibreglassreinforcedAPPmodifiedbitumenmembranewithaslatefinish,referredtoelsewhereinthismanualasArdexWPM555(ShelterbitPhoenixStar).

External MoistureTocomplywithNewZealandBuildingCodeAcceptableSolutionE2/AS1bitumenshinglesshouldbelaidataminimumpitchof17.5˚.

UnderflashingsFixShelterbit380mmunderflashingstovalleysetc.andalsoasastartercoursealongthebottomoftheroofallowinganoverlayintothegutter.AllsurfacestowhichtheunderflashingsaretobefixedshouldbeprimedwithArdexWPM240(ShelterPrimer).

Laying1. Markachalklinehorizontallyalongtheroofone

shingleheightup.Thismarksthetopofthefirstrowofshingles.

2. Thecontourededgeofeachshingleprovidesthecorrectspacing.Thetopedgewhenbuttedalsopreventswaterblowingbackuptheshingle.Thetopofeachshingleisthenfixedwithfourgalvanisedclouts.Tolocatethenextrowmarkahorizontalchalklineuponeshingleheightminustheoverlapontothelowershingle.

3. ThelowerhalfofeachshinglemustbeheatedbyliftingtheshinglebackandheatingtheundersurfacebythesamemethodusedtoapplyotherTorch-onmembranes.Caremustbetakennottodiscolourthemineralsurfaceoftheshinglebelow.Apieceofplywoodcanbeusedtoprovideamaskandaworkingplatform.ThetoprowofshinglesmaybecuttosuittheapexandaShelterbitMineraloverflashingusedtofinishtheridge.Anyloosemineralshouldbebrushedofftheroofwithasoftbroom.

4. Theheatedshingleisthencarefullyrolleddown,payingattentiontothelappededges.

Roofareacoverageper50shinglesisapproximately3.57m2.

Four galvanised clouts on each shingleBottom row of shingles with Shelterbit Mineral underflashing

Dotted lines indicate flashing beneath shingles

Flashing into gutter

380m

m

ArdexWPM555(ShelterbitPhoenixStar)isappraisedinBRANZCertificateNo463(2011)asanAlternativeSolutiontoE2/AS1.

March2012

StandardShinglesApproximately580x290mm,50%overlapoftheshinglebelow.

58

ARDEX WPM 240Shelter Primer

SolventBasedPrimer

DISCLAIMERThetechnicaldetails,recommendationsandotherinformationcontainedinthisdatasheetaregiveningoodfaithandrepresentthebestofourknowledgeandexperienceatthetimeofprinting.ItisyourresponsibilitytoensurethatourproductsareusedandhandledcorrectlyandinaccordancewithanyapplicableNewZealandStandard,ourinstructionsandrecommendationsandonlyfortheusestheyareintended.Wealsoreservetherighttoupdateinformationwithoutpriornoticetoyoutoreflectourongoingresearchanddevelopmentprogram.Countryspecificrecommendations,dependingonlocalstandards,codesofpractice,buildingregulationsorindustryguidelines,mayeffectspecificinstallationrecommendations.Thesupplyofourproductsandservicesisalsosubjecttocertainterms,warrantiesandexclusions,whichmayhavealreadybeendisclosedtoyouinpriordealingsorareotherwiseavailabletoyouonrequest.Youshouldmakeyourselffamiliarwiththem.

59

ARDEX WPM 240Shelter PrimerSolvent Based Primer

PRODUCT DESCRIPTION

ArdexWPM240(ShelterPrimer)isasolventbasedbitumenmodifiedprimertobeusedtosealandpreparethesubstratepriortotheinstallationoftheShelterbittorch-onandSheltersealselfadhesivemembranes.

APPLICATION

Ensurethatthesurfacetobeprimedisdryandfreefromdust,oil,paint,curingcompoundsandanyothercontaminatingmaterials.Stircontentswellbeforeuse.Applybybrush,rollerorairlessspray.ArdexWPM240(ShelterPrimer)mustbedrybeforeapplyingmembrane.

COVERAGE

1litreofArdexWPM240(ShelterPrimer)willcoverapproximately5m2.

DRYING TIME

Allow1-2hours@23°C.

LIMITATIONS

ArdexWPM240(ShelterPrimer)shouldbeusedwithappropriatemaskandbreathingapparatusinareaswithpoorventilation/airflow.

PACKAGING

5Land20L

STORAGE

12monthsintheoriginalunopenedpackagingstored@23°C.

INDENTIFICATION

Blackliquidcomprisingbitumendissolvedinmineralspirits.

CLEAN UP

WashequipmentwithArdexWA98S.

SAFETY DATA

First Aid:Swallowed:Givewatertocleanmouth.Donotinducevomiting.Skin:Removecontaminatedclothing.Washskinthoroughlywithsoapandwater.Eyes:Holdopenandfloodwithwaterforatleast15minutes.Inhalation:Removetofreshair.Ifbreathingisdifficultadministeroxygen.Ifirritationcontinuesseekmedicalattentionpromptly.

March201260