An Evaluation Of Amniotic Membrane Allograft As A Potential Agent For Biological Augmentation
Of Rotator Cuff Repair
Adnan Saithna1, Jennifer Z. Paxton2, Uchena Wudebwe2, Liam M. Grover2 and Martyn Snow1
1The Royal Orthopaedic Hospital2School of Chemical Engineering, The University of Birmingham
![Page 2: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/2.jpg)
![Page 3: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/3.jpg)
![Page 4: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/4.jpg)
AMA and tendon repair
• Reduction of peri-tendinous adhesions (Ozgenel at al 2004 & Demirkan et al 2002)
• Favourable influence on collagen deposition (Yang et al 2010)
• Improved mechanical properties (Yang et al 2010, Ozbuluk et al 2010, He at al 2002, Ozgenel et al 2001)
![Page 5: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/5.jpg)
Micronised AMA
![Page 6: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/6.jpg)
Cellular Proliferation Study
![Page 7: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/7.jpg)
0% SerumLow A.M. High A.M.
Images taken on Day 7
![Page 8: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/8.jpg)
Manufacture and Maintenance of “Bone-Tendon” Constructs
Manufacture:- 35mm Sylgard coated Petri dish- Brushite anchor (Bone substitute)- Fibrin Gel (soft tissue substitute)- Seeded with 100,000 Chick Tendon Fibroblastss- DMEM + 10% FBS, 2.4% L-glutamine, 2.4% HEPES- 1% penicillin/streptomycin
Maintenance:- Incubated at 37°C, 5% CO2
- Fed with s-DMEM every 2-3 days
Ascorbic acid (250µM) and proline (50µM) were added on day 7 onwards, along with AMA (13µl/ml DMEM) in the treatment group.
![Page 9: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/9.jpg)
Typical sequence of maturation
![Page 10: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/10.jpg)
AMA Dosing
• Cost prohibitive
• “One vial per cuff” strategy
• Calculation based on previous work on surface area of soft tissue attachment to the brushiteanchor (Paxton et al, Ann Biomed Eng, 2010)
• Rotator cuff footprint area (Mochizuki et al, JBJSAm 2009)
• 13uL per ml of DMEM
![Page 11: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/11.jpg)
Fibrin Gel Contraction• Constructs photographed daily and image J analysis
software was used to assess area and rate of contraction. No significant difference was demonstrated between control and treatment groups
-200
0
200
400
600
800
1000
1200
DAY 0 3 5 7 10 15 27
Area of constructmm2
Day of Culture
A
B
C
![Page 12: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/12.jpg)
Mechanical Testing
• Instron Microtester
– 37oC Water Bath
– 10N Load Cell
– Load applied at 0.4mm/sec
– Load/Extension and mode of failure recorded
![Page 13: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/13.jpg)
Mechanical Testing - Results
• The mean maximum load to failure of the hard/soft interface in the control group was 0.33N (+/-0.24) and 0.23N (+/-0.10) in the AMA group. No statistically significant difference was demonstrated between groups (p=0.371).
0
0.1
0.2
0.3
0.4
Control AMA
Ma
xim
um
Lo
ad
(N
)
Treatment
![Page 14: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/14.jpg)
Collagen content
• There was no difference between groups with respect to ug of hydroxyproline per mg of tissue Control 35.76ug +-10.19, AMA 31.7ug +/- 8.49, p=0.72
0
5
10
15
20
25
30
35
40
45
group D group E
ug
hyp
pe
r m
g o
f ti
ssu
e
![Page 15: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/15.jpg)
Discussion
• AMA had no significant effect on cellular proliferation , collagen content, or on the mechanical properties of the interface.
• In contrast to previous work. However these animal studies used human amniotic fluid or membrane rather than a micronized preparation and also investigated mid-substance tendon healing rather than the specifically investigating the bone/tendon interface.
![Page 16: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/16.jpg)
Limitations
• Dose of AMA restricted by cost
• In vitro study – so not the whole picture
• Model only evaluates fibroblasts
• No inflammatory component
![Page 17: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/17.jpg)
Future Directions
Localised AMA delivery
- Anchor encased in 150uL of fibrin containing a single dose of 26uL of AMA
![Page 18: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/18.jpg)
Mechanical Testing - Localised AMA
• A trend towards increased maximum load to failure was seen in the AMA group but this was not significant (control 0.20N (+/- 0.13), fibrin 0.21N (+/-0.02), fibrin + AMA 0.29N (+/-0.02)
0
0.05
0.1
0.15
0.2
0.25
0.3
0.35
Control Fibrin Fibrin+AMA
Ma
xim
um
Lo
ad
(N
)
Treatment
![Page 19: Biological Augmentation Of Rotator Cuff Tears](https://reader034.vdocuments.us/reader034/viewer/2022052418/58ee28841a28abc85b8b465f/html5/thumbnails/19.jpg)
Conclusions
• No benefit of AMA at a maximum cost effective dose for clinical application.
• Model allows easy in vitro assessment of potentially therapeutic agents but has some limitations.