![Page 1: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/1.jpg)
Biocide Water Treatment Program to Mitigate Coiled Tubing FailureCase Study for Monitoring and
Treating Bacteria in Coiled Tubing Fluids
ICoTA Calgary 2015
Presented By Jeremy LuthDirector – Business Development NA
![Page 2: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/2.jpg)
Biofilm Formation
![Page 3: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/3.jpg)
Microbial Influenced Corrosion (MIC)
![Page 4: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/4.jpg)
Coiled Tubing Failure
![Page 5: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/5.jpg)
Results
![Page 6: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/6.jpg)
Technologies
ATP Monitoring Solid Biocide (powder and stick)
![Page 7: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/7.jpg)
ATP Monitoring Method
![Page 8: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/8.jpg)
ATP Measurements
Treatment based on pg/mL ATP
0 – 50 pg/mL 50 – 100 pg/mL 100 – 1,000 pg/mL >1,000 pg/mL
No action is necessary
Develop plan for treatment
Executemoderate treatment
Execute aggressivetreatment
Continue monitoring
Maintain monitoring frequency
Increase monitoring frequency
Double monitoring frequency
![Page 9: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/9.jpg)
Execution
![Page 10: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/10.jpg)
Objectives for Pioneer Energy Services (PES)
• Increase operating life
• Add predictability
• Improve safety
• Increase profitability
![Page 11: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/11.jpg)
Intro to PES Coiled Tubing Unit (CTU)
• 2.375-in. string
• 21,500 ft long
• Grade 100 steel
• Average failure = 20% fatigue / 12 trips
![Page 12: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/12.jpg)
PES CTU – Case Study #1
• Avg. = 10,623 pg/mL ATP (9,235 & 12,010 pg/mL)
• On-site volume = 2,500 bbl
• Treatment = 4 units of biocide
• 12 hours post-treatment = 147 pg/mL ATP
• Circulating pressures dropped from 7,250 psi to 5,750 psi (50 MPa to 39.6 MPa)
![Page 13: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/13.jpg)
PES CTU – Case Study #2
• Start = 1,536 pg/mL ATP
• On-site volume = 2,800 bbl
• Treatment = 1 unit of biocide
• Six hours post-treatment = 78 pg/mL ATP
• “Fresh” water increased to = 607 pg/mL ATP
![Page 14: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/14.jpg)
Results
• Increased string life by 3X
• Strings retire at expected fatigue
• No failures since treatment program implementation
• Increased revenue by $750,000/string
![Page 15: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/15.jpg)
Implementation
![Page 16: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/16.jpg)
MIC Areas
Papers regarding MIC in CT operations:
1. SPE 1736752. SPE 1736583. IPTC 18032
Horn River
Montney
Eagle
Ford
PermianWoodford
![Page 17: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/17.jpg)
Acknowledgements
• Luke Menard – Pioneer Energy Services
• Adam Cluff – Pioneer Energy Services
• Scott Sherman – Trican Well Service
• Dustin Palombo – STEP Energy Services U.S.
• Michael Merks – OSP
• Kim Dockens – OSP
• Stan Leong – OSP
• ICoTA and you, the audience
![Page 18: Biocide Water Treatment Program to Mitigate … 2015...Biocide Water Treatment Program to Mitigate Coiled Tubing Failure Case Study for Monitoring and Treating Bacteria in Coiled Tubing](https://reader031.vdocuments.us/reader031/viewer/2022021703/5e7424b7fa16440c745698cc/html5/thumbnails/18.jpg)