bim coordination portofoliooo
TRANSCRIPT
BIM COORDINATION PORTOFOLIOArchitect BIM Coordinator : Mohab Magdy Mohamed M:0097430327104 Email: [email protected]
1-Sample for Coordination Process :
2-Sample for Central Files Hirecahy :
SOME SAMPLE FOR PERVIOUS MODELS.
Sample For Discrepancy Flag Inside The model To Detect the Clash Easily Through The Filters.
1-Sample For Discrepancy Status Inside The Schedule With Discrepancy ID to Detect and Modify The Clashes Easily Through Discrepancy Flag.
2-Documentation For The Clashes Inside Excel sheet.
SAMPLE FOR INTERFERNCE CHECK REPORT
BY REVIT & NAVISWORKS
INTERFERENCE REPORT BY REVIT:
Interference Report By Navisworks:
SAMPLES FOR BIM COORDINATED 2D&3D CLASHES & DISCREPENCIES And COORDINATION MEETINGS
ASUMPTIONS WITH STAKEHOLDERS.
BIM Discrepancy Description: References: StatusThere is a conflict in the location of (BWO) at the structure drawings (SM.103A.18) and the arch. Ceiling (CLG-02) at the Arch. drawings (AM1.413.18) in (MC.18.03.B21).
SM.103A.18AM1.413.18Revit Model
New �
ID: AR-FF-347 Page 1/1 Active-BOJV ��
Active-BIM �
Zone: MU_L3Active-PMC �
Resolved �
Stage Description By Date
BIM Team Assumption: Postponed Michael 16-Jul-2013
Coordination Meeting Action 1: Refer to dwg no. 280136 Silvia (TO) - Enji 25-Feb-2014
Coordination Meeting Action 2:Coordination Meeting Action 3: .
Stage Description By Date
BIM Team Assumption: Follow arch drawing and reduce the height of the structural beam. MOHAB MAGDY 20-Nov-2013
Coordination Meeting Action 1: Follow RFI no. (405076-1750) Ashraf Mounir -
Enji15-Jan-2014
Coordination Meeting Action 2: Refer to RFI – 405076-1750 rev A Abram Mohsen 17-Sep-2014
BIM Discrepancy Description: References: StatusConflict Between Arch DWG AM1.103.13 And Structural DWG SM1.103.13 in (MS.13.03.001)
AM1.103.13SM1.103.13
New �
ID: C0-CD- Page1 Active-BOJV �
Active-BIM ��
Zon MU-L3 Active-PMC �
Resolved �
Stage Description By DateBIM Team Assumption: mohab 05-Dec-2014
Coordination Meeting Action 1:
Issue to be solved between HVAC & Structure as discussed with Francois and Juan.
surnda-TO 26-Nov-2014
Coordination Meeting Action 2:
Check the openings with MEP since we will maintain only the ones needed (and in reasonable locations).
Ahmed amin .
BIM DiscrepancyDescription: References: Statusconflict between the structure drawings (SM2.322.03) and the roller shutter detail (AM6.955) at MP.12.03.002 , MP.13.03.003 , MP.13.03.001
SM2.322.03SM2.324.03AM6.955AM6.954
New �
ID: C0-CD-310 Page1 Active-BOJV TO �
Active-BIM Team �
Zon MU-L3 Active-PMC �
Resolved �
Stage Description By DateBIM Team Assumption: Postponed mohab 24-Feb-2013
Coordination Meeting Action 1: - -
The actual
concrete beam
BIM DiscrepancyDescription: References: StatusConflict in concrete level between structural plan DWG ( SM1.103)(+47.4) with the arch section (AM2.344)(+49.4)At the gridline ( S23)( fall arrest missing in design )
AM1.103SM1.103AM2.344
New �
ID: C0-CD-308 Page2/2 Active-BOJV TO �
Active-BIM Team �
Zone MU-L3 Active-PMC ��
Resolved �
Stage Description By Date
BIM Team Assumption: Follow structural Level and if follow arch DWG we must put handrail in N elev. because different level 1.50m M.Magdy 29-Nov-2013
Coordination Meeting Action 1: RFI-285062-1926 Dina – Salam– Mary (TO) 07-Jan-2015
Coordination Meeting Action 2: .
SAMPLES FOR CODING CLASHES
Coding DiscrepancyDescription: References: StatusMissing item in BOQNo foundation with 700mm thickness
in the BOQ
Book 2A – Bill 2 Part 1 - 2/1/2SM1.10G.19
Element ID: 4045565 NewID: 001 Pag
eActive-BOJV Active-BIM
Zone: BOQ Active-PMC
Resolved
Stage Description By Date
BIM Team Assumption: Assumed to be classified as ‘pad foundation’ (2/1/2/M) mohab 30-Apr-2013
Coordination Meeting Action 1: Confirmed samer 13-Jun-2014
Coordination Meeting Action 2: -
Coordination Meeting Action 3: -
Coding DiscrepancyDescription: References: StatusMissing item in BOQNo foundation with 2000mm
thickness in BOQ
Book 2A – Bill 2 Part 1 - 2/1/2SM5.451
Revit Element ID: 3632958 NewID: 002 Pag
eActive-BOJV Active-BIM
Zone: BOQ Active-PMC
Resolved
Stage Description By Date
BIM Team Assumption: Assumed to be ‘mat foundationof 1900mm’ (2/1/2/L) Mariam 30-Apr-2012
Coordination Meeting Action 1: Confirmed MOHAB 13-Jun-2014
Coordination Meeting Action 2: -
Coordination Meeting Action 3: -
SAMPLES FOR MANUAL COORDINATION USING 2D COORDINATION TECHINQUE USING XREF FILES IN
AUTOCAD AND LINKED TO REVIT.
The Progress Modeling & Coordination Status: